1. Real time charts by selecting this type of graphic whenever the quantity is stored the graph will be updated by showing the quantity trend in real time You need to select the length of the time period to be used in creating the graph See Cap 3 5 3 for more information about the database graphical view Static charts by selecting this type of graphic you will obtain the graph for a certain period between the first and last instance of storage in the database showing the trend for stored measures over the selected period Once these options have been chosen you can then decide which instruments and groups are to be used for creating the graphics 3 3 4 The Chart windows Measure P Aver ala 2al Static view From 017102004 00 00 00 To 08710 2004 23 45 00 Section A e Section B Mote click on the graph to see the measurement value FIG 28 This pictures show a static Chart the you can generate with WarpNet Software The Toolbar has four buttons e Copy to ClipBoard windows as picture the Chart e Print the chart directly to the Printer e Add or Remove a line alarm 3 3 4 1 Button Copy to clipboard The first button permit to copy the image of Chart in Windows ClipBoard This operation allow to paste the Chart in any active windows application like Word or Photo Paint 27 WarpNet V2 8 DUCATI energia s p a 3 3 4 2 Print button The button prints the chart Clicking the button opens the standard pri
2. 15 mar 2 Monday Profila_3 r Start date 15 mar Weekly Profile Monday E Protilo_3 Tuensday Wednesday Thursday JES Profilo_3 Friday Saturday EA Profe O A Sunday EA Profe f Cancel Ok Cancel Ok Saturday Profilo_1 4 Sunday Protila_1 01 mag seen Monday Protilo_4 evn Tuensday Profil 4 Hemare FIG 9 Look at previously figure on the left side the are current assignment Select modify or add for view and modify on the right side the weekday assignments 3 1 6 4 Section Special days In this section is possible to assign a profile to a particular day of the year like Christmas zi Edit and modify time bands Standard Special events Annual fix events Date Profile Add Profilo_1 Madii Profilo_1 Mion Profilo_1 Profilo_1 Profilo_1 Profilo_1 Remove I Profile for day after Easter E Profilo_1 Date venerdi 30 gennaio 2004 Profile Day Profile 2 sora a Barcel WK ance Ok Cancel Ok FIG 10 11 WarpNet V2 8 DUCATI energia s p a On the left is possible to assign a profile to a particular day of specific year and it will be used one time only for that particular date On the right are listed all annual fix day every year on that days it will be used the profile assigned Note Profile for Easter Monday Warpnet finds Easter and allows to assign a profile for the monday after 3 1 7 Offline Activating this option will
3. Display period from To 17 55 27 05 2002 1257 3070572002 Pala FIG 30 There are two options Dynamic table Select this option for obtain a dynamic table calculate between the date selected and the last memorization The data are recalculate using profile selected Static table Select this option for obtain table calculated between the period select The data are recalculate using profile selected 3 3 6 View time bands energy table g Time bands table Static view 27 05 2002 17 55 31 30 05 2002 12 57 00 Groups Fl KWwh Fe Rh Fa kwh Fa RWh MACH Fi EWh F2 kwh FS kwh F4 EW Demo U2 0 000 0 000 0 000 0 000 Demo 03 0 000 0 000 0 000 0 000 Demo 05 0 000 0 000 0 000 0 000 Demo E 0 000 0 000 0 000 0 000 P F Corector 02 0 Lighting 01 0 000 4 000 1 000 3 000 MBS 0 000 0 030 0 020 0 030 Lighting 02 0 000 0 040 0 500 0 050 Litt 01 0 000 0 050 0 010 0 060 Lighting 03 0 000 4 000 1 000 3 000 Office Plane 02 0 000 0 030 0 020 0 030 Lighting 04 0 000 0 040 0 040 0 050 Office Plane 01 0 000 0 050 0 010 0 060 Purnp 01 0 000 0 180 0 060 0 150 Purnp U2 0 000 0 180 0 060 0 150 Demo 0 0 000 0 040 0 000 0 000 Demo O4 0 000 0 040 0 000 0 000 Without Group 0 000 0 000 0 000 0 000 Building 2 600 6 200 Purmips 0 120 0 300 Smart Pi 0 000 FIG 31 FIG 31 shows a time band energy table in static view The toolbar has two buttons 29 WarpNet V2 8 DUCATI energia s p a 3 3 6 1
4. 398 zam HH Lift C4 90 age g7 af ano me Next table update at 17 22 gio 30 05 2002 Nest Store at 17 22 go 30 05 2002 Nest Synchronization at 06 00 ven 31 05 2002 Last record at 17 20 gio 30 05 2002 Acquisition in progress BEE FIG 1 WarpNet V2 8 DUCATI energia s p a 3 1 File Menu This section of the program menu handles all operations carried out on files New Network project Open Network project Open OffLine Save Ag Export Measures OFF line Exit FIG 2 3 1 1 How to create a new network project New Network Project The user can now create a network project on his own PC in order to do so select New Network Project fromthe File menu or click the respective button on the toolbar LU The following window will appear in which a name should be entered this name will be used to create the directory and give a name to the project files New Netwotk project Name Network project directory MBIGSERVERSDSWAR PNETSS ILAS W Yw arpi et Pl EI FIG 3 3 1 2 How to open an existing network project Open Network Project Firstly click File gt Open Network Project from main menu or the icon on the toolbar the standard dialogue box for opening files will appear proceed in the usual manner WarpNet V2 8 DUCATI energia s p a Cerca in E SRC Al ce Bithi aps DECort Progetto Esempio RES Tipo file WAD Annulla 2 FIG 4 After op
5. Setup functions you first need to create a DLC resource see Chapter 3 2 1 Creation and management of DLC resource DLC Setup and set up an Instrument Network see Chapter 3 2 2 How to configure the network of analysers to be associated to a DLC MACH Setup Next go to the main menu and click Configuration gt Session Setup Session E4 Data Storage w Sunchronization Quarter of hour recording One time at the end of first Store Every 7 Day s at time Jo6 00 Screen refresh period Data recording every Data recording interval Joo oos0 30S refresh oo15 00 Hest Store at 08 45 mar 28 05 2002 Available measure F F Corrector 01 F F Corrector 02 Cos fi Cos fi 1 Cos fi Cas fi 4 Litt 01 lL inhkinea MM FIG 20 A session of measurement consists of a set of acquisitions relating to measures and time period that are both user selectable 3 2 4 1 The data recording interval The user can select the following parameters in the Data storage box 21 WarpNet V2 8 DUCATI energia s p a e screen refresh period e How many refresh periods must occur before data recording Data Storage Screen refresh period Data recording every Data recording mterval Jonoos0 4 30 refresh fonis 00 The two parameter determine the data recording interval For example inserting one minute in Screen refresh period and 5 in Data recording every the storage happen every 5 minut
6. a tiny difference from the stored value For instance the value 50 0 may be shown as 50 0000000000001 or 49 999999999999999 To see all the decimal digits drag the column in the table Sy WarpNet V2 8 DUCATI energia s p a 3 5 3 How to export the stored measurements Export When you click Export the following dialogue box will appear A Expotation Exportable Measure P Aver F F Corrector 01 Kwh J F F Corector 02 Building o Add those measures to all the gruop ee EE Lighting oF Bl Select all Unselect all Add those measures to all the network View of Database record Available data from i755 lun 27 05 2002 To 10 50 mar 28 05 2002 z gE E sportation Interval from 23 20 lun 2705002 To 05 21 mar 20 05 2002 FIG 34 The network configuration is displayed on the left Each item selected by checking the check box to its left will now be exported Each selectable item on the left corresponds with the associated measurements on the right warning if a single instrument or group is not selected on the left the associated measurements on the right will not be visible and these can be selected as well Four buttons may speed up the task of choosing the measurements to be exported Add those measures to all the group offers the possibility of adding all checked measurements to those already selected for the other instruments of the group vi If deciding to export the
7. be synchronized the automatic synchronization can be disabled unchecking Synchronization check Box The synchronization command as two options i This minimum value for the parameter is calculated automatically in accordance with the complexity of the network 22 WarpNet V2 8 DUCATI energia s p a e One time at the end of first Store this option force a reset after the first acquisition and storing This operation then does not occur any more e Ever XX Day s at time hh mm this option allow you to setup a regular synchronization You have to select at what time you wish to get the network synchronization and how many days waiting for the next automatic new reset interval selction The first command is issued at the first match of the clock time After the first command the program will wait the preset days interval before sending the next one 3 2 4 3 Setup the measure session The figure below illustrates the selection of a group i Setup Session Ea Data Storage W Synchronization T Quarter of hour recording One time at the end of first Store Every Day s cy attime 06 00 Screen refresh period Data recording every Data recording interval J00 00 30 30 refresh 00 15 00 a Next Store at 08 45 mar 28 05 2002 Available measure Freq y We Wed WaT F F Corrector 01 VIN Veh F F Corector 02 VSN Building I1 oo 2 E Cos fi Cos fi 1 Cos fi 2 Cine fi 4 Linhir
8. of the project and the data For example use it before making an important modification to the project 3 1 5 Manage time bands Warpnet can manage any time bands profile and can generate a file or a print of energy consuming divided for each time band Next dialog window allow to select the active profile from list below This choice influence both table of measure and the export of measure Custum tariff profile set Standard FIG 6 Using this interface you can e pushing add button add a new profile e pushing Modify button modify an existing profile e Pushing Del button delete an existing profile 3 1 6 Add or modify an existing profile Next dialog window appear both for add and for modify a profile For the first case all windows are blanc and you must insert the correct values iii See also the chapter about Database management for more information WarpNet V2 8 DUCATI energia s p a 3 1 6 1 Section Time bands In this section is possible to insert all time bands in use by the delivery agent Edit and modify time bands Standard ine parna FIG 7 Press add modify for add modify a new or existing time band and insert the name choice the colour and the cost for each KWh Use Del button for delete a time bands remember you are not allowed to delete a time band that is used in a day profile 3 1 6 2 Section Day profiles This section is dedicated t
9. on the left show the names of the instrument groups and the names of the MACHs assigned by the user to each group respectively The Configure button can be used to exclude one or more measures from being displayed in the table There are 5 different colours for the data boxes as indicated in the table above the grid Red reception error The measurement in question has not been received as a result of either a reception error or an instrument malfunction This means that the measurements taken will be missing from the database Green measurement not selected Indicates that the measurement is among those available for that particular instrument but the user has not selected it in the group to be stored Blue measurement not available The measurement in question is not present amongst those that can be taken by the MACH to which the box corresponds Grey measurement not visible 24 WarpNet V2 8 DUCATI energia s p a Should the user decide that he does not want to display certain measurements for example in order to make a table more readily comprehensible the configure button allows him to choose which boxes to display or hide If you select an entire column not to be visible it will be automatically hidden and even the grey will no longer be displayed Yellow undefined measurement If the instrument is operating but the measurement requested cannot be taken it will respond with undefined measurement For example if curren
10. opposite command see below or switch the instrument off and back on again Unlock keyboard button This command restores the option of accessing the Setup menu from the instrument keyboard 3 2 3 About instruments groups Group Setup From all networks configured by the user with WarpNet it is possible to select instruments whose measurements are of special significance in order to form separate groups e g from a network of instruments installed throughout the company you might wish to highlight the data regarding the instrument group situated in the MV LV transformer substations The groups in this software are merely treated as instrument grouping rules and although some measurements are associated in actual fact nothing is stored are generated by recalculating on each occasion the sum of stored measurements associated with the instruments from which they are obtained Each change made to composition and number of groups will not result in any change to previously stored measurements This means that if we create a group after recording for two months all measurements will be recalculated when necessary and despite not having previously been configured it will have a record of these last two months likewise if we delete a group and then recreate it exactly the same as it was before this will retain all data 17 WarpNet V2 8 DUCATI energia s p a In order access group creation and management functions you first need to create
11. with dozens of instruments and when it has been completed a list of all instruments correctly inserted in the network will appear in the MACH Network window Choosing a MACH will enable the buttons on the right that are used to configure and check Following any change to the configuration in the Network box the Save and Cancel buttons are enabled 3 2 2 2 Save button This command allows you to save network configuration as it currently stands 3 2 2 3 Cancel button This command allows you to restore the last configuration you had saved 3 2 2 4 Configure button 4 Setup Address 4 Mame Lighting WT Ratio K fi average Time fio CT Ratio KA fi a gt Read write Command Reset raged TE Power Reset Energy E E Lock Keyboard Unlock Keyboard FIG 15 Y If required the software will also support new DUCATI instruments released on a subsequent date A standard icon will appear to indicate that it does not have the specifications of that particular instrument in its database 16 WarpNet V2 8 DUCATI energia s p a This command offers the possibility of configuring several essential Ducati instrument parameters as well as sending the most common commands such as write and read to a predetermined instrument transformation ratio KV of the voltage transformer connected to the voltmeter inputs average value calculation time and transformation ratio KA of current transformer connected to the a
12. 0 MACHOS MACHO MACH11 MACH Te Cancel MACH13 MACHT 4 MACH15 MACHTE MACHIT MACH1E MACH19 9 MACH 20 kiA H71 id End FIG 14 Clicking the pointer arrow of the DLC box will open the drop down list of names of configured DLCs Having selected the name you can access the MACHs installed on the respective RS485 line In the example above a DLC named DLC 01 is selected This operation will enable the Search button 3 2 2 1 Search button This command enables WarpNet to analyse the network of instruments in order to identify connected MACHs on the basis of their address In fact the MACH list contains three types of icon e The question mark indicates that no check has ever been carried out on that address therefore the system does not know whether a MACH exists e The red X ts indicates that an unsuccessful attempt has been made to interrogate the MACH at that address therefore the system considers that instrument either absent or out of service and it will be deleted should it have been present amongst those available in the network e The corresponding icon for each instrument of the Ducati family an icon has been inserted showing its photo e g iz for MachSmart 96 15 WarpNet V2 8 DUCATI energia s p a In order to complete these details two additional columns are provided that advise the type of instrument and the Firmware version contained therein The search can last twenty seconds or more for networks
13. Cs For example if choosing Resource COM for the DLC named ONE and a modem 1s installed on that port the resource COMI will no longer be available to the DLC named TWO either amongst the serial ports or as a modem Select Ethernet option if you have a DLC Ethernet code 458001220 The default IP for this module is 192 168 5 245 with 2000 as port No limit for DLC connected are implemented But you can connect max 98 instrument for each DLC Having chosen the type of connection the Advanced button will be enabled with which the user can Set the length of the timeout regarding use of the serial line for data transmission Changes to this parameter are somewhat critical and could cause a malfunction during acquisition 3 2 2 How to configure the network of analysers to be associated to a DLC MACH Setup Having set DLC attributes the user can set up the network of analysers connected to it by using the MACH Setup command from the Network Project menu of the main control panel thus opening the MACHs Configuration window 14 WarpNet V2 8 DUCATI energia s p a MACH configuration x DLC MACH DLC 01 MACH Network E A Addess Name Model E 41 Configure Test w e 1 F F Corector AMI12 2 43 ia 2 Purnp MachSrmart trita 2 02 A ZE Pump 02 Smart36 0 50 r 4 Lighting MachSmart trita 4 00 ie z elevator Smartie 2 0 MEg MBS MachSmart trifa 2 00 E MACHO g Oven Mach30 54 da 2 3
14. DUCATI energia s p a Via M E Lepido 182 40132 BOLOGNA Casella Postale PO BOX 4052 BorgoPanigale Phone 051 404140 Fax 051 402040 WEB www ducatienergia com WarpNet V2 8 USER S MANUAL The Best Wav Manage your MACH Network 10 2007 WarpNet V2 8 DUCATI energia s p a TABLE OF CONTENTS 1s INSTALLATION sitctet cose ceet cate ceereretsaelsawestacsticcnsadesecuemeetecesuge ese sudavass sons a 3 2 GENERAL DETAILS arisia 3 3 USING THE WARPNET SOFTWARE aassnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnna 5 3 1 File Ment oira E r TE 6 3 1 1 How to create a new network project New Network Project nnnuneesessssssssssssseeereresrrsssssssssssssseeereeresssssss 6 3 1 2 How to open an existing network project Open Network Project ccccssseeeecceceeceeeeeeaaaeesessseeeeeeeeeeeeees 6 3 1 3 How to open an existing project without connection to DLC open offline eesssssssessssssesseeeeressssssssssssee 7 3 1 4 Howto Make a copy of the project in use Save a amp cccccscesecccccececeeeceeaeseseseseeseeeeeceeeeeeeeeeeesasaeasseeeeeeeeeeess 8 ILS Manase Ome Wands catadics ean annette a a a ob eedae satan re Ea meee nates 8 3 1 6 Add or modify an existing prolilesec ste de cacsctesdserdec adeoddat ad detesaeesantuavesecs coseotedsasaecsensd vasdudeaceoen vende Mesecees oases 8 3 1 6 1 SECON L E DANIS tare a enn ee E NR rc ae er Ee ee ere ee 9 3 1 6 2 SECON Day PLOM
15. PC The software utilises the serial ports in order to communicate with network instruments It can manage all the instruments of the Ducati Family MACH 20 30 Smart Smart 96 Smart Pi and Smart 96 Pit RMI Rego DAT Pit integrated instrument and also any instrument of the latest generation Thanks to the updateable database the software is able to distinguish and understand the number and type of the instruments connected to the network in order to enable highly selective handling e g make available for selection only such measurements as can actually be used with that particular instrument In order to enable RS 485 communication the PC requires one or more of the following instruments depending on the number of serial ports in the system e Ducati DLC RS232 RS485 converters expressly recommended e Ducati DLC Ethernet RS485 converters expressly recommended e DAT Pi data logger Only as added functionality WarpNet V2 8 DUCATI energia s p a In theory the software supports an extremely large number of instruments if you consider that with four serial ports it should be possible to manage up to 392 of them In practice however networks of this size cannot be handled in a satisfactory manner the problem is linked to instrument transmission and response speed In fact the length of time between initial acquisition of the first instrument and final acquisition of the last instrument would be such as to make the
16. Print button 8 This button is used to make a hardcopy of the table When the button is pressed the software show the standard printer dialog box Select the printer and press print 3 3 6 2 Save button This button is used to make a copy of the table in a text file Select the output file and press Save 3 4 Tools Menu This section contains all those commands that can be given to network instruments at the same time or in any event in quick succession Command Section This section contains the commands available for all network instruments If you are using instruments of the latest generation such as Smart Piu or later this command will have immediate effect thanks to broadcast command whilst in the case of a mixed network for all other instruments it will be given in succession Since the system recognises the various network instruments it will automatically send first the broadcast command 1 e single command interpreted by all new instruments and thereafter will deal with all old instruments connected to the network Reset Energy this command allows you to reset energy for all network instruments Reset average power this command resets average and maximum average power This will also result in resetting of the instruments internal timer that from that moment will begin counting the time set in the Average Time parameter Lock keyboard this command will block local access to the configuration menu from the i
17. SAV UU OD eseo EENT TETN T 30 WarpNet V2 8 DUCATI energia s p a 3 4 Tools MMUSI 30 Dees SEUD Secesia ES 30 3 5 EOE CC MICASUINC E A E T E A E O TE 30 RL Manase mebla a E E E E orca sanes 30 39 2 How to view the measurements View sisc csscsseiisdas crept nna E E E A ieee 32 3 5 3 How to export the stored measurements Export ccccccccccceccccecceeesseeseseeeececeeeeeeeeeeeeeeeusaeseaeseeeeeeeeeeeeaaaas 33 3 5 4 How to import from a CSV file Import cc cessssssssseeeccceeceeeeeeeaaesesssseeeeeececeeeeseseeeaaaaaaseeeeeeeeeeeeeeeeaqaas 34 A WARPNET CLIENT ostecscewsceuscetecsteceneanpieeaneetacenanelep eaeetcs cue nanan eneaabenoieneneieiebeatseeediaeiee 35 4 1 F sta laO seora wae essa a a EE E Oer E 35 4 2 EM A EEE T E E N E E E E 36 WarpNet V2 8 DUCATI energia s p a 1 Installation In order to run WarpNet you will require e IBM compatible personal computer with Pentium II processor or higher e operating system Windows 98 ME or Windows 2000 with Service Pack 4 or Windows Xp with Service Pack 2 Windows Vista 1s not supported e atleast 128 MB of RAM e at least 100 MB of free space on hard disc e CD DVD Reader only for installation Before installing WarpNet close all application running on the PC The installation is started by running the setup exe program from the CD ROM 2 General details WarpNet software is designed to provide user friendly control over networks of analysers connected to a
18. a 14 FIG 23 In order to show that a measurement needs to be stored simply tick the box next to it The Add this selection to all the group button will arrange to add the selected measurements for the instrument currently being displayed to all MACHs in the group 23 WarpNet V2 8 DUCATI energia s p a 3 3 Display Menu 3 3 1 How to display data acquired in table form Measurement sessions allow the acquisition of vast amounts of data concerning three phase network voltages currents power power factors etc thanks to all the MACHs that make up the measuring network created by the user Data regarding the measures chosen by the user during the session setup stage can be viewed in table form Simply go the Display Menu and click Measurement table Table of data i el E Aecerving error Measure not selected Measure not available Measure not visible Undefined measure 7 si Ii Demo U2 Without Group Demo 03 FO 8 Demo 05 FO a aa a aa o Demo 0 7 ao a elec P F Conector 01 SMM O P F Corector 02 E a o O O Lighting 01 E l a aa 2am zai MBS cp ae g5 228 zagi 7 1 Lighting 02 a0 an 4000 20 aa om o Lift 01 9 ago oso Lighting 03 ao o sa He Office Plane 02 37 ag a6 228 ons soo Lighting 04 407 a Hos Office Plane 01 99 za Oooo Pump 01 ie Bo Pump 02 re E S ee eee Demo 01 so 4040 0 a Demo 04 so 4050 o aa H Building Pumps FIG 24 Data are displayed in columns the first two
19. a DLC resource see Chapter 3 2 1 Creation and management of DLC resource DLC Setup and set up an Instrument Network see Chapter 3 2 2 How to configure the network of analysers to be associated to a DLC MACH Setup following which you can go to the main menu and click Network Project gt Group Setup a Setup Groups linstruments groups Groups Measures Delete FIG 16 The screen is divided into two sections on the left the DLC installed in the system and on the right the Groups already created there are also two arrow buttons that allow you to move Network instruments from one section to the other and four other Group Setup buttons The DLCs configured in the system are displayed on the left In this tree like arrangement leaves are used to depict the instruments connected on the RS485 line corresponding to the DLC representing the root Instruments connected to two different DLCs can also be associated to a group The right hand section shows the names of previously created Groups present as roots and the instruments associated to them as leaves It should be noted that two copies of the same MACH cannot exist in fact those on the left are considered as not being assigned to any group whilst those on the right as associated to the respective group An instrument cannot be associated to two different groups so this means that a MACH is either displayed on the left no group or will be situated on the right By c
20. e On the other hand should you select a data save time of Quarter of hour the above mentioned parameters are set automatically See precedent the picture 3 2 4 2 The synchronization of the network Set this option allows the possibility of synchronization all the instruments of the net Synchronization One time at the end of first Store Every 7 Days at time 06 00 FIG 22 Synchronizing the instruments means to send to all the network instruments a reset command for the mean values computation e g average power See Cap 0 Command Section Thanks to this command all the instruments will restart the mean values computation at that moment resulting in the contemporary average computation in the same time interval for all the instruments in the network Of course to get all the benefits of this feature it is required that all instruments are programmed with the same Average Time parameter mean interval time After sending this reset command for all the acquisitions during the first following mean period you will get stored 0 values on all the mean and maximum values e g mean power This effect is inevitable if the data are stored before the reset the 0 will appear on the following acquisition if the reset is sent before the storing of data the 0 will appear in this acquisition In case in a measurement session you are not interested in the average values or rather you are not interested them to
21. emo 03 so sora YF Demo 05 7 403 Demo DE 7 ae CC F F Corrector 01 AL F F Corrector 02 BU Lighting 01 MBS Lighting Oz Lift AT 401 399 396 400 398 qr Nest table update at 17 22 gio 30 05 2002 Nest Store ak 17 22 gio 30 05 2002 Nest Synchronization at 06 00 ven 37 05 2002 Last record at 17 20 gio 30705 2002 Acquisition in progress BEE FIG 35 Opening a session with WarpNet Client is similar to opening the same session in Off Line mode with WarpNet with the only difference that e itis not possible to view or modify the Groups or the Session settings e the disabled menu in WarpNet are NOT shown with WarpNet Client 36 WarpNet V2 8 DUCATI energia s p a DUCATI energia S p A shall accept no liability for damage or personal injury arising from incorrect or improper use of its equipment This manual refers to WarpNet version V2 8 or later This documentation is subject to change without prior notice Documentation code UserManual_WarpNet28_OA doc Version 0 A October 2007 DUCATI energia s p a Via M E Lepido 182 40132 BOLOGNA P O Box 4052 BorgoPanigale Phone 051 404140 Fax 051 402040 WEB www ducatienergia com a7
22. ening the file the software will start again automatically from exactly where you left off For example if you were acquiring data acquisition will resume if you were configuring you can continue from where you left off A quick way to delete a folder from the list and send to the recycle bin is to select it and use the DELETE key following which the Confirm File Delete box will appear Confirm Folder Delete Are you sure you want to remove the folder Sample Project and all its contents FIG 5 WARNING This will result in the permanent deletion of all information about network configuration and all measurements taken thus freeing up space on the hard disk 3 1 3 How to open an existing project without connection to DLC open offline This feature allows to open a WarpNet s file without making connection with DLC and so without start the acquisition The user is allowed to do a restrict number of operations only those which do not required a connection Allowed are e The exportation e Static Graphs e Database of measure Management e Modify the group association See the next chapters for information about the arguments below 7 WarpNet V2 8 DUCATI energia s p a For the use of the dialog box see prevision chapter 3 1 4 How to Make a copy of the project in use Save as In every moment is possible to make a global copy of the project including the data This command is used to make a Back up copy
23. ents By default the fundamental measurements associated with a group are e active power e average active power e active energy 3 2 3 4 How to delete an existing group Delete button By clicking this button it 1s possible to delete one of the previously created groups in actual fact this operation will not bring about any change to previously stored measurements that are not touched in any way As in the case of the Edit button this becomes active as soon as an existing Group is selected If deleting a group containing some MACHs these are automatically reassociated to the respective DLCs 3 2 3 5 How to add an instrument to a group Arrow button Having created a group see Chapter 3 2 3 1 How to add a new Group Add button simply select it choose a MACH from amongst those displayed on the left and click Right arrow that will light up in green ai Setup Groups linstruiments groups Pump Group 9 Pump 01 DLE 01 a Shed Group Measures FIG 19 20 WarpNet V2 8 DUCATI energia s p a In this example the MACH MachSmart 96 known as Elevator is about to be inserted in the Shed Group Likewise to remove a MACH from a group simply select an instrument from the panel on the right in order to enable the Left Arrow button In this manner after clicking the button the MACH will be reassociated to the respective DLC 3 2 4 Starting and managing measurement sessions Session Setup In order access Session
24. ere are two options e Save in a new project the selection During the execution of this command WarpNet will ask the user where to save the new project After this questions it will create a new directory with the new project name and copy the entire project without the unselected data The user can open in a successive time the duplicated project for example using Open offline command See Cap 3 1 3 How to open an existing project without connection to DLC open offline e Delete the selected database records This command will delete all records of the selection and the records can t be recovered To enabled this command the selection must include the first or the last record to do it automatically use the two button on left Mil and the on the right Both these options can be used at the same time resulting as cut and paste command At the end of the operation a message indicate the result At the end of all operations the database is compacted automatically This operation can take a long of time with database larger then 300 Mb Moreover being an atomic command it is not possible to show a progress bar and therefore the program can appear locked during this procedure but is not The command Compact ar doesn t require any selection since it refers to the whole measure database This operation is recommended after having managed the measures or Mach such as deleted since the simple deletion itself of records doesn t pr
25. les Sedes a a r e a E rE E aes 9 3 1 6 3 SECON Pernod yaaga a a oa E E 10 3 1 6 4 DECOM O PeCakday S e e a EEN 1 IEC QUINE nara nan aA tarde eva iaai ais a E OE EEAO NATA OAAS 12 3 2 Network Project IVC IMUM ico iss as aes asc ae ods ce ads ce oes dee eaae esei dobara Nee iN seedee Teaia hanai d ENAERE 12 3 2 1 Creation and management of DLC resource DLC Setup 2 0 0 0 cccssssssseseeeeeeeeeeeeeeeeeaaaaesesseessseeeeeeeeees 12 3 2 2 How to configure the network of analysers to be associated to a DLC MACH Setup eee 14 3 2 21 Searc EDIO anann OS NT a On 15 S222 SAVE DUM ON sx cspcctsccarinctinesencanteedecaseshestazdousecstaahennaderdeaseushestandeveccsteasenenadesdeoneusbe ART 16 S225 Cancel DUO Nnnna E E E E 16 3 2 2 4 COMETS UTE DOON eaae N E 16 S25 AbDoutimstfumentsSroups Group SCP espire E EEEE OEKE EEEE T EEE 17 3 2 3 1 How to add anew Group Add Dutton ii ecsincssuubssdenioeneupleteawedennduodsasandudeswmnssaeboadsdsonduuansonaaranseusacbececs 19 52 52 How to change the name of a group Edit button cccssssseeesseeeeeeceeeeeeseesaaseeeesseeseseeeeeeeees 19 3 25 9 How to change measurements associated with groups Groups Measures button 19 3 2 3 4 How to delete an existing group Delete button 2 0 ccccccssssseeeeeeeececeeeeeeeeeeeeeeeaasaaseenseseeeeeeeess 20 323 How to add an instrument to a group Arrow button 0 eeeeeeeeseseeeeeeeeceeeeeeaaaaeeesseeseseeeeeseeeeeeeaaas 20 3 2 4 Starting and managing mea
26. licking the sign it is possible to expand the icon and see which instruments correspond to that object 18 WarpNet V2 8 DUCATI energia s p a 3 2 3 1 How to add a new Group Add button To add a new group to those present you need to give it a name using the following box Add Insert the group s name Annulla Fump Group FIG 17 The new group will be displayed as an icon along with the respective name 3 2 3 2 How to change the name of a group Edit button This button is used to change the name of a previously created group It will only become active if you select a group by clicking with the mouse 3 2 3 3 How to change measurements associated with groups Groups Measures button Clicking this button accesses the change function for measurements associated with groups by bringing up the following window La 4 Groups related measure Mas ver F P Aver P Mas P Aver Pe Aver P3 Aver P1 Maz P2 Max Pia Mas Wid VA Aver VSM ae Wa VAZ YAS YAT Aver VAZ Ayer YAS Aver 19 WarpNet V2 8 DUCATI energia s p a In this section you can select in the usual manner which measurements are to be associated with the groups These measurements will be automatically inserted amongst those selectable for all instruments and cannot be deselected whilst selecting the measurements to be registered The set of groupable measures are a subset of the measurements made available by the various Ducati instrum
27. measurements for a group they cannot be chosen individually but will be exported in their entirety 33 WarpNet V2 8 DUCATI energia s p a Add those measures to all network instruments performs the same task as the previous one adding the measurements to all network instruments Anyway if the instruments on the left are not selected the associated measurements will not be exported Select all all instruments groups and available measurements are selected for export This is the default setup Unselect all this command offers you option to export nothing at all There are also two boxes that can be used to select the start and end of the time period to which export should correspond Show time bands adds a column to the output file with the time band of the measure Export interval To choose the export interval is possible to use the graphic bar named View of database record and also manually insert in the box below the value of the first and last date to export In any case the graphic bar represents the interval selected Once all choices have been made you can proceed by clicking export This operation will open a standard file save dialogue box the export format is Comma Separated Value the column delimiter is whilst as regards numbers the decimal separator depends on the configuration chosen in the control panel and the file extension is CSV 3 5 4 How to import from a CSV file Import Before importi
28. mmeter inputs How to change the name of Instruments Rewrite the text on the box named Name After this in all the project this instrument is indicated with this text Read button This command simply updates the three fields displayed in the box by communicating directly with the instrument in question using Ducati protocol Write button This command sends to the instrument selected the parameters entered in the various boxes at that particular time Having finished programming automatic reading takes place in order to be able to receive confirmation as to whether or not said programming of the instrument has been successful Reset Avg Power button This command irreversibly resets average and maximum average power of the instrument under examination We would remind you that subsequent updating of the quantity will occur at the end of the period set as average time with effect from the moment in which reset takes place Reset Energy button This command irreversibly resets the energy meter of the instrument under examination We would remind you that subsequent updating of the quantity will occur as soon as the instrument registers the minimum quantum of energy Lock keyboard button The lock keyboard function offers the possibility of preventing a user present at the instrument installation site from accessing the Setup menu once the various on screen messages have finished This command will remain operative until you send the
29. nd therefore undefined 3 3 3 How to display data acquired in graphic form Graphics are an even more explicit form of displaying data In this manner it is possible to monitor and calculate data trends over certain periods of time This is useful for example when analysing the setup of a system s average active power consumption in order to compare with the contractual values agreed with the electricity supplier Various graphic windows can be created each one showing different trends associated with single and groups of MACHSs You can set the data graphic analysis configuration by accessing the Display menu from the main window and clicking Add Chart Window Hew Graph Measure a Without Group T z s N SENE g Derma oe Ok C Real time charts al iMoney Demo 03 9 t gt Wave ih Display the last E Purun GE Demo 05 zl fF Hours LIS Cancel Demo 06 E imate N a f Static charts Data from To 17 55 lun 27 05 zj 08 37 mar 287 057 zj Display period from To Jon 23 mar 2605 07 11 mar 28 057 FIG 27 26 WarpNet V2 8 DUCATI energia s p a The dialogue box has various sections as can be seen in the next figure Measure this option lets you select the measure to display in graphic form After choosing this parameter you will see a list appear on the right that is restricted to the groups and MACHs having that particular selection amongst their associated measures
30. ng a CSV file created from the WinCom5 program you should perform the following two steps 1 Create anew Network Project 2 Add a DLC connected to a serial port The Ethernet option will not work Import the measurements selecting Stored Measure gt Import insert the filename from where to import and confirm with OK The progress bar shows the import status and the number of imported rows The WinCom5 program usually adds new rows to the CSV file every day therefore the same file will be peridically imported again All subsequent imports will only add the rows with a DIFFERENT date time from those already in the database This will cause the one hour period of measurements during the transition from Daylight Savings Time to normal time to be discarded The imported sessions are always opened Offline Warning When the number of instruments or the measurements of the DAT are changed a new Session must be created otherwise the new measurements will be discarded Before importing a new session please check that the destination disc is not full and that the CSV file remains available if it is on a network folder vii Care should be taken when exporting a file with a certain setting for decimal numbers and importing in another PC with different settings the data could be interpreted incorrectly 34 WarpNet V2 8 DUCATI energia s p a 4 WarpNet Client WarpNet Client software is designed to provide user friendly access o
31. nstrument keyboard Unlock Keyboard this command will restore the possibility of accessing the configuration menu from the instrument keyboard 3 4 1 Setting section Average time this command is used for fast setting of a single predetermined average time on all instruments This command is carried out in sequence 1 e it is given to the instruments one at a time therefore there will be a slight shift in time when the next measurement update takes place for this reason if you have a network of new instruments such as the Smart Pi which support Broadcast commands we recommend resetting average power See chapter 0 Command Section in order to increase system synchronisation after this setting 3 5 Stored measure In this section you can manage the data of the database 3 5 1 Management This dialog allow to save or delete the data in the database of measure 30 WarpNet V2 8 DUCATI energia s p a amp Measure Database Managment View of stored records Avallable data from i755 lun 2705 2002 To 08 37 mar 28 05 2002 Hdl Selected Interval from 23 06 lun 24054002 To 04 06 mar 26 05 4002 Lal Save in a new project the selection peee Selected database ecos Compact Execute Exit FIG 32 This dialog window presents two sections one represents the Database and the selection in graphical mode See chapter 3 5 3 and one to select the command to apply to the selection In the second section th
32. nter dialog 3 3 4 3 Setup alarm button The al button opens the window shown in the picture below Once activated all the options for the alarm can be selected Setup Alarm Threshold Value aos T Measured Value Alarm Value gt FIG 29 The Threshold Value is the value used for drawing the line on the Chart See chapter 3 3 4 The Chart windows The check box named Blink on Alarm cause the blinking of the chart window the white background is alternated with the red one Below it can be selected the condition for the chart alarm Keep in mind that in case you have more curves displayed the alarm condition is activated on all the displayed objects in the chart Moreover the method for checking a possible alarm condition depends on the type of chart displayed in case of dynamic charts then the condition is applied only to the latest stored value while in case of a static chart all the points of the chart are used for alarm condition 3 3 4 4 Remove alarm button The a button removes the alarm settings 3 3 5 How to view the energy consuming dived by time bands Select View gt time band table from main menu With the next dialog box is possible to see the energy consuming divided by time bands during period selected 28 WarpNet V2 8 DUCATI energia s p a CE Gvramic table Time for calculating start 0 00 01 01 2005 z Data from To 17 55 27 05 2002 i257 3070572002
33. o the manage of day profile It s possible to create profile using time bands previously inserted You need to create one profile for each different prototype day Select a time band and associate it to an hour WarpNet V2 8 DUCATI energia s p a A Edit and modify time bands Standard Time bands Profiles Period Special days 08 00 F3 ha 09 00 F2 13 00 F3 ladi 15 00 F2 17 00 F1 19 00 F2 21 00 F3 22 00 F4 Profilo_ 10 fj 00 00 F4 A 08 00 F3 09 00 F2 A 10 00 F eo 1200F2 Profiles Mame Profilo 1 0 Color Click M E Modity Remove Time band E F4 hour 0o00 Cancel Ok nance WK Cancel Ok FIG 8 For example in profile 10 the F4 time band is used from 00 AM to 8 AM and from 10 PM to 00 AM Use Del button for delete a profile remember you are not allowed to delete a profile used in Periods section 3 1 6 3 Section Periods In this section is possible to assign each profile previously inserted to a period of the year Select the date for the beginning of new period and For each day of the week select a day profile 10 WarpNet V2 8 DUCATI energia s p a zi Edit and modify time bands Standard Period Periods table Sunday Profilo_1 Ua 08 gen l ETEN Monday Protilo_e ladit Preeren Tuensday Protilo_ eae Wednesday Profilo_2 eae Thursday Profila_2 ae Friday Pratila_2 a Saturday Profilo_1 AEE Sunday Frofila_
34. oduce a reduction of database dimension This kind of operation could be time consuming according to the size of archive so try to use this command frequently and maintain the database at a right dimension in order to keep the management operation time in acceptable values 31 WarpNet V2 8 DUCATI energia s p a 3 5 2 How to view the measurements View This menu item opens a window that shows a table with the stored measurements and a drop down list to select the instrument to use a Section A Iof x Data e Ora P3 p PHak ver 1072004 00 00 00 120 eo o 1072004 00 15 00 210 2000 o 1072004 00 30 00 120 2000 o 1072004 00 45 00 120 2000 1072004 01 00 00 120 2o00 10142004 01 15 00 120 2000 o 1072004 01 30 00 160 2000 o 1072004 01 45 00 170 2000 o 1072004 02 00 00 120 2000 o 1072004 02 15 00 120 2000 o 1072004 02 30 00 120 2000 o 1072004 02 45 00 120 2000 o 1072004 03 00 00 190 2000 o 1072004 03 15 00 140 2000 o 1072004 03 30 00 120 2000 o 1072004 03 45 00 120 2000 o 1072004 04 00 00 0 0 o 1072004 04 15 00 120 120 o 1072004 04 30 00 200 370 o 1072004 04 45 00 130 40 o 1072004 05 00 00 120 3r i o 1072004 05 15 00 120 370 TO 00a NR A 120 m 4 d Section 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FIG 33 The numeric format of the measurements stored in the database and in this view are not identical therefore some measurements with decimal digits may be rounded with
35. result totally invalid Satisfactory response times are obtained with networks of up to 150 connected MACH bearing in mind however that total acquisition is directly proportional to both number of MACH and number of measures to be acquired WarpNet allows you to carry out three basic operations 1 Display the current situation in table form 2 Store and export a set of measurements associated with the instruments and groups of them 3 Display the progression in time of a quantity in graphic form In order to have an estimate of the mean acquisition time of all the data of a network the following formula is applied T No MACHs x No quantities per MACH x 0 15 sec 4 WarpNet V2 8 DUCATI energia s p a 3 Using the WarpNet software Start the WarpNet program from the Start menu selecting Programs gt Ducati gt WarpNet The first window shown will be the one of FIG 1 e Warp Het Sample Project Oe File View Configuration Tools Stored measure Window 7 Di ce bl Ei x static view From 30 03 2002 14 14 10 To 307032002 13 18 10 o LAEE data Receiving eror Measure not selected Measure not available Measure not visible Wes WJ aT WI TN Vv ven W VGN Vv Demo 0z 410 eae eae 236 Demo 03 47 4 HH Demo 05 409 409 236 237 236 Demo D 409 409 236 236 236 F F Corector 01 220 o o o S o F F Corector 02 2 a a ae a ea Sas Lighting 01 A ana as aT MBS ep g 3 2239 229i Lighting 02 3990 aoo
36. stop the acquisition In this modality the WarpNet all the connections are closed communication ports are freed and all commands that require a connection with the instruments are disabled Use this command when it is necessary to modify the structure of the Network Using Open offline see Cap 3 1 3 How to open an existing project without connection to DLC open offline this modality is automatically enabled 3 2 Network Project Menu This section of the main menu handles network configuration Any change to this using one of the Menu commands will lead to acquisition being suspended and if a network configuration is already operative the following dialogue box will appear This command will suspend the measurament Session would yuo like to continue FIG 11 click Yes to display the previously selected configuration interface and halt acquisition 3 2 1 Creation and management of DLC resource DLC Setup Situated between PC and analyser network the DLC is the RS232 RS485 signal converter that converts the signal of the PC serial port from standard RS232 to RS485 It should be noted that N99 subject to disabling its store function the Dat Piu data logger can also be used for this purpose albeit with a few network speed restrictions If you have already completed the configuration of a network but would like to expand it by adding a DLC to a free serial port you can do so but during configuration of this new reso
37. surement sessions Session Setup sssessesssseecceceeeeeeeeaaeseeeseeeeeeeeeeeeeeeeseeeaas 21 3 2 4 1 Thed tarecordine IEVA i asserir eE NE 21 3 2 4 2 Thesynehronizatioii of Te ME CW OL osne tases nn a S E E ANENE 22 3 2 4 3 Setup ihe Measure Sess lOl aein ane E e E E E S E EUNN 25 3 3 Display Meni ces ezesaaeeecneve ces ccosans tarara EEEE EE 24 3 3 1 How to display data acquired in table form ccccceesssseeececececececeaeaeeesesseseeeececeeeeeeeeceeeasaaaaassseeeeeeeeeeeaeaas 24 3 3 1 1 Tabular display options COnfiQure r ceoiiiirencnanri E a a EEE 25 3 3 2 How to display group data acquired in table form neeeesesssssssssssseerreesssssssssssssseerrrerrsssssssssssssseereeresssssss 26 3 3 3 How to display data acquired in graphic fOLM cccccceceeccccccecceceeeesesessssseeecceeeeeeeeeeeeeeasaaaessseeeeseeeseeeeaaaas 26 Seo Fhe Wait WAN OWS mennun a E N a ein eiauee mason 2 3 3 4 1 BUON COpy TOC lI DDO s tees isasl a gas haga Awa eRandcnlu ison T 2 3 3 4 2 Prae DOON e r a a turd Sie a a a Dang ua eagts 28 3 3 4 3 SC DUO a a a a a a Rialius eae tetn mre omuanans 28 3 3 4 4 Remove alarni DUNO aa a a a a a a a a dlsiauarneuus semis 28 3 3 5 How to view the energy consuming dived by time bands ossooosoeeenesssssssssssssssseeererssssssssssssssseerereessssses 28 LRO Vew mE DAN GS ENEL CY LAD E neron ond nen EEE A OEE E E 29 3 3 6 1 Print DOON esetre a E esas sadencaunnes EENE E E AR 30 3 3 6 2
38. t is zero it is not possible to measure the power factor 3 3 1 1 Tabular display options Configure O Setup iew a 4 without Group se Y Shed Group A Lighting DLC 01 E elevator DLC 01 Hide the selected mesure in all the network Select all FIG 25 In order to hide the quantity of a MACH simply select the instrument on the left and on the right tick any measurements you don t want to be visible Select All allows you to select all measures that appear and display them in the table This will basically take the display back to its original configuration Use of the button Hide the selected measures in all the network allows the user to hide the quantity selected in all MACHs of the network This will result in the respective column being hidden whilst displaying in table form 25 WarpNet V2 8 DUCATI energia s p a 3 3 2 How to display group data acquired in table form Besides displaying individual measurements this software also allows you to view group values in real time Table of groups Shed Group FIG 26 In this display the first column shows the group names whilst the others contain the associated measurements If the symbol appears this means that one or more MACHs present in that group have an incongruous measurement e g timeout or overflow This will lead to an error in the measurement database since the figure obtained from the sum of the measurements is not correct a
39. urce acquisition will not be possible If you find yourself in this situation and run the DLC Setup command from the Network Project menu the following window will appear 12 WarpNet V2 8 DUCATI energia s p a FIG 12 This displays the DLCs that have already been configured By clicking the plus sign you can see various properties of the DLC PC connection On the right there are 4 buttons whose functions are described below e Add adds anew DLC to the network configuration e Edit Changes the configuration of the DLC selected becomes active when a DLC is selected from the list e Delete Irrecoverably deletes DLC from network including configuration of associated instruments and also deletes from database all related data regarding the measurements taken e Exit exits display mode in order to enable acquisition to resume or allow the user to modify others parts of the configuration When clicking Add or Edit a dialogue box appears that allows you to set the attributes of the connection with the DLC 13 WarpNet V2 8 DUCATI energia s p a DLC Setup E4 DLC Name DLC C RS5 232 cable connection Com Serial port IF Remote host ame Remote port FIG 13 The user must enter the Name numbers or letters or both to be assigned to the DLC and choose the type of connection between PC and DLC The software will automatically prevent the user from assigning the same resource to two different DL
40. ver a network to a WarpNet database 4 1 Installation In order to run WarpNet Client you will require e IBM compatible personal computer with Pentium II processor or higher e operating system Windows 98 ME or Windows 2000 XP with the latest Service Pack installed Windows Vista is not supported e at least 128 MB of RAM e at least 100 MB of free space on hard disc e CD DVD reader only for installation e A PC monitor with at least 1024x768 pixels of resolution e A network connection to the folder where WarpNet is installed The WarpNet folder must be shared for reading and writing from the PC where WarpNet Client is installed Before installing WarpNet Client close all application running on the PC Installation is achieved by running the setup exe program from the CD ROM using My Computer or the Run option from the Windows Start Menu 35 WarpNet V2 8 DUCATI energia s p a 4 2 Using WarpNet Client Start WarpNet Client selecting gt Programs gt Ducati gt WarpNet from the Start menu The first time WarpNet Client is run it will show the main window of FIG 35 a Warp Net Sample Project File View Configuration Tools Stored measure Window 7 Daly hk jan Ei i mitatic view From 30 05 2002 14 14 10 To 30 05 2002 13 18 10 z S Table of data Receiving error Measure not selected Measure not available Measure not visible Freq Hz v12 WOT WJ IN W 2N 7 VSN w Demo 02 50 H0 237 27 28 D