Home

NX-PA/PD - OMRON Industrial Automation

image

Contents

1. omRONn NX PA PD External Interface NX PA9001 cas PA9001 PWR POWER Indicator PWR LED m EREEREER AC input L1 ope Ser A a Connector AC input L2 Be i CEE e eh a Elle tells RUN output a D E NX PD7001 A PD7001 POWER Indicator PWR LED Iconnector Le DC input Op T 1 ace DC input me J LG ae i GR pe D j RUN output D kn outpu dre es i ial AC Input Supply 100 to 240 VAC allowable 85 to 264 VAC The NX PA9001 has a wide input range so it does not have voltage switching terminals DC Input Supply 24 VDC allowable 20 4 to 28 8 VDC LG Ground to a resistance of 100 or less to increase noise resistance and avoid electric shock GR Ground to a resistance of 100 or less to avoid electric shock RUN Output The internal contacts for the RUN output turn ON when the CPU Unit is in RUN status omRONn NX PA PD Wiring About Power Supply For AC DC power supply Recommended wire AWG 14 to 20 diameter Cross section 0 5
2. removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsible for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled stored installed and maintained and not subject to contamination abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron com global or contact your Omron representative for published information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the
3. 17 to 2 08 mm For grounding wire Recommended wire a 2 mm or thicker diameter Crimp Terminals The terminals on the Power Supply Unit are M4 self raising terminals with screws Crimp Terminals for AC Power Supplies Crimp Terminals for DC Power Supplies 7 mm max rmm OF Crimp terminal for the grounding wire 7mm max DH 7m max OG Precautions for Use Compatible CPU Models NX PA9001 NX PD7001 are dedicated for NX series oOmROoOn Dimensions NX PA PD Unit mm NX PA9001 NX PD7001 PD7001 Related Manuals Manual name Cat No Model numbers Application Description NX series W535 CPU Unit Hardware User s Manual NX701 Learning the basic specifications of the NX series CPU Units including introductory information designing installation and maintenance Mainly hardware information is provided An introduction to the entire NX series system is provided along with the following information on a Controller built with a CPU Unit e F
4. NX Series Power Supply Unit NX PA PD Powerful power supply unit to supply stable power to the NX series controller CSM_NX PA_PD_DS_E_1_1 Stable power supply is available from the NX series CPU Unit to each I O Unit via the dedicated bus Lineups are provided for AC input types with 90 W output and DC input types with 70 W output NX PD7001 Features e AC input types with 90 W output or DC input types with 70 W output allows power supply to large scale configurations e Operating output contact indicates the CPU operation status available in all models Ordering Information International Standards e The standards are abbreviated as follows U UL U1 UL Class Division 2 Products for Hazardous Locations C CSA UC cULus UC1 cULus Class Division 2 Products for Hazardous Locations CU cUL N NK L Lloyd CE EC Directives C Tick C Tick mark and KC KC Registration e Contact your OMRON representative for further details and applicable conditions for these standards Power Supply Units Output x z Options capacit Product Name Power supply ee Model Standards voltage Total power 24 VDC service RUN output Maintenance consumption power supply p forecast monitor AC Power 100 to 240 Supply Unit VAC 90 W NX PA9001 No Yes No ko CE RCM DC Power Supply Unit 24 VDC 70W NX PD7001 Accessories There is no accessory for the NX series Power Supply Unit Sysmac i
5. eatures and system configuration e Introduction e Part names and functions e General specifications e Installation and wiring e Maintenance and inspection Use this manual together with the NJ NX series CPU Unit Software User s Manual Cat No W501 omrRONn Terms and Conditions Agreement Read and understand this catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right c Buyer Remedy Omron s sole obligation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for
6. individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT S IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitability and does not constit
7. s a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products Other company names and product names in this document are the trademarks or registered trademarks of their respective companies omRONn General Specification NX PA PD Item Specifications Model NX PA9001 NX PD7001 A A 80 X 100 X 100 mm 51 X 100 X 100 mm Dimensione WXH X D WXH X D Weight 570g 290 g 100 to 240 VAC wide range 50 60 Hz 85 to 264 VAC 47 to 63 Hz 24 VDC 20 4 to 28 8 VDC Power supply voltage Power consumption 150 VA max 85 W max At 100 VAC At 24 VDC Inrush current 1 pret A max for cold startAt roomiterniperature 30 A 2 ms max for cold start at room temperature 40 A 2 8 ms max for cold start at room temperature 7 A 3 3 s max for cold start at room temperature Total 90 W max Output capacity 4 Total 70 W max Output terminal Service supply Not provided Contact configuration SPST NO Switch capacity 250 VAC 2 A resistive load 120 VAC 0 5 A inductive load 24 VDC 2A resistive load RUN Output Replacement notification function Not provided 20 MQ min at 500 VDC between AC external and GR terminals 5 2 300 VAC 50 60 Hz for 1 min between AC external and GR terminals 5 7 6 Leakage current 5 mA max Insulation resistance 6 Dielectric strength 1 The inrush curren
8. t may vary depending on the operating condition and other conditions Therefore select fuses breakers and external power supply devices that have enough margin in characteristic and capacity considering the condition under which the devices are used 32 If the ambient temperature is higher or the Controller is hot started the inrush current given in the table may be exceeded by up to twice the given value because the thermistor element with a low temperature current control characteristic is not sufficiently cool 3 Of the inrush current values the latter value varies depending on the input voltage and may rise to approx 8 3 A at 20 4 VDC 4 Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted 5 Apply the voltage between the Power Supply Units L1 or L2 terminal and the GR terminal when testing insulation and dielectric strength The tests can also be performed with the LG terminal and GR terminal connected to each other In this case the leakage current will be 10 mA or less 6 The primary DC power supply and the secondary DC power supply are not isolated 7 Change the applied voltage gradually using the adjuster on the Tester If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester the generated impulse voltage may damage the Power Supply Unit
9. ute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application requirements Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the Product may be changed without any notice When in doubt special part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions 2015 4 In the interest of product improvement specifications are subject to change without notice OMRON Corporation Industrial Automation Company http www ia omron cony c Copyright OMRON Corporation 2015 All Right Reserved