Home
3DIW8 - User manual
Contents
1. Do not operate the unit in premises where condensation can form Operating conditions of the unit are defined in the Specifications section 1 Safety precautions Version 2 04 March 2014 Inteliwasher 3D IW8 Page 3 DURING OPERATION Do not operate the unit in environments with aggressive or explosive chemical mixtures Please contact manufacturer for possible operation of the unit in specific atmospheres Do not operate the unit if itis faulty Always have the cover protecting against aerosol spread hereinafter protective cover installed during operation Do not operate the unit if any needle is clogged or malfunctions Never touch the needles or place fingers or other parts under the needles during operation Manifold needles are sharp and can cause injury Always switch off the unit before changing the manifold Do not allow the waste bottle to overflow the maximum level during operation there is a mark on the side surface of the bottle Take necessary precautions utilizing waste liquid in accordance with general laboratory standards AFTER OPERATION Carry out the cycle of system washing on the unit front panel use the button System rinsing with distilled water and do not dry This will keep the system in permanent operation condition BIOLOGICAL SAFETY It is the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment In diagnostic researche
2. March 2014 4 Operation Page 12 Inteliwasher 3D IW8 4 19 4 20 When the cycle is completed a sound signal will inform that the unit stopped the operation Move to paragraph 5 of chapter Operation closedown ofthis manual Attention Always perform the rinsing cycle using distilled water after finishing the operation at the end of working day This will help to keep the unit in working order and prevent head channel clogging Plate setup When installing a plate for the first time or when a plate of different type is used set up the manifold needles lowering depth 4 20 1 Pressing the Enter key in the start mode and navigate to PLATE SETUP using and keys the following message appears on the display fig 9 4 20 2 To confirm calibration press the Run Stop key The manifold will measure the depth of the plate well by touching the plate surface first and then the bottom of the well Then it will save the difference of the values measured Shake CLES Dispense rate 03 Aspirate rate 03 Soak limit s oo Shake limit s 30 Fig 9 Manifold lowering depth identification Dispensed volume 300 Aspirate time ms 1000 Final aspirate ms 2000 Wash by rows YEs Num of wash cycles o3 Thechannel a Second chan cycles on Secondchannel oz Table 3 All parameters of programs with two channels WASHING PROGRAM Plate setup Press RUN button 4 Operat
3. collecting of waste liquid o o o o o 1 piece Hydrophobic filters for half litre bottle 0 020 ee 2 pieces Manifold cleaning set 20 ec eee bees 1 piece Syringe for liquid flushinginhoses 0 0000 cee ete ee 1 piece POWeENCONd a ao ahs beaded one bh nodes rada eens 1 piece Operating manual certificate 2 2 ae 1 copy 4 channel washing solution weight logger 4CHW Logger 00 on request Fig 1 Delivery set Version 2 04 March 2014 3 Getting started Page 6 Inteliwasher 3D IW8 3 3 gt 3 3 3 1 3 3 2 3 3 3 3 4 2 3 4 2 3 4 3 Storage and transportation During long term storage it is recommended to keep the unit and all its accessories in original packaging in a dry place protected from dust Note Remove the washing solution completely from the hydraulic system in case of long term storage more than 8 hrs Use the original packaging for transportation whether transported by air water or land Attention We do not accept warranty claims related to damages caused by improper packaging To pack the unit properly Remove the manifold tubes and platform for plates Puton packaging blocks onto sides of the unit and place it into the original carton box Place the manifold into the protecting case the syringe the manifold cleaning set and the platform into the polythene bag Place the bag the case with the manifold in the corners o
4. side of the rail will move the platform into start position Fig 2 Installation of platform and manifold 3 Getting started Version 2 04 March 2014 Inteliwasher 3D IW8 Page 7 cr Note If the plate platform is installed improperly the magnet will not hold it in place and the platform will be able to move freely Move the platform along the rail until the magnets lock Increase of resistance to movement indicates that the magnets are locked 3 4 5 Unpack the manifold 3 4 6 Place the manifold on the holder arm so that the guide pins of the manifold slide into the respective grooves of the holder arm fig 2 3 3 4 7 Connect the manifold inlet connector supplying the liquid and the Washing Head Dispense blue connector at the rear panel of the unit fig 3 2 with the tube fig 1 7 3 4 8 Connect the manifold outlet connector and the Washing Head Aspirate gt connector at the rear panel of the unit fig 3 4 with the tube fig 1 8 cr Note Use the provided labels for marking bottles with washing solutions and bottles for collecting waste liquid and aerosol 3 4 9 Connect the Waste bottle outlet 4 green on the rear side of the unit to the connector of 2 litre bottle number 4 for collecting of waste liquid fig 3 1 3 4 10 Place the tube for the hydrophobic filter fig 1 9 on the half litre bottle number 5 connector then place the hydrophobic filter on the tube fig 1 13 When installing the fi
5. 0 eee 8 Numberofwashing CycleS ooooococc eee ae 1 15 e ASPIFAtON Ume dioramas la Balad ee nb ara db Goan 0 2 3s Aspiration dispensing speed a a a a a aa A Ea E a A E a a eee 3 levels Choice of 3 washing buffers o DiSpense SYSTEM raea ar A aa wale x sphincter valve AA NN 0 300s incrementis 10s Number of washed rOWS ooo 1 12 Time of plate single wash 300 pl ooooccooccco eae max 65 s Number Of programs ines esta iaa brad a da ie whine 101 Plate platform and manifold movement a oa nnana automated Indication of operationmodes asasan asama aaa aa a ete 8 line LCD DIMENSIONS aa ar AAA SE A A a eo OO a 375x345x180 mm A ii 2 24 EN EE EES E A Ad a 9 6kg Input current power consumption oooocooco 00 e eee eee 12V 1 8A 22W gt External power supply unit inputAC 100 240 V 50 60 Hz output DC 12 V Optional accessories Description Catalogue number 4 channel washing solution weight logger 4CHW Logger max loading per scale cup 2 kg logger dimensions BS 060102 AAI 267x252x97 mm weight 3 kg Replacement parts Description Catalogue number Bottle 1 Assembled with weight tube filter BS 060102 S26 Bottle 2 Assembled with weight tube filter BS 060102 S27 Bottle 3 Assembled with weight tube filter BS 060102 S28 Bottle 4 Assembled with tube BS 060102 S29 Bottle 5 Assembled with filter tube BS 060102 S43 Hydr
6. EI Wao ass 2 g al 2 100 00 00 00 2 Era bg VW S o 3 DO 00 001 O0 ze 5 QQQ QQQQQQQQQ 3 00 DO 100 00 N E 2009009222220 z 21 DO DO DO DO ah E QQQQQQQQOQQQO amp 2 2 0O DO G Co rr gl 00 00 00 00 000000000000 Ulla DO 001 OO 00 Scheme 1 The FastFRAME Schleicher amp Shuell multi slide plate or analog plate of another manufacturer that is compatible with standard 1 x 3 inch 25 x 76 mm glass slides acp NOTE Optional 4 channel washing solution weight logger 4CHW Logger allows automatic buffer bottles and waste bottle volume control The unit is supplied with 8 channel washing head for dispensing aspiration 3 bottles for washing and rinsing solutions a waste bottle and small bottle with hydrophobic filter that eliminates risk of contamination with bacteria viruses and infected particle from wasted liquid to an atmosphere Hydrophobic filter bacterial efficiencies is very high up to 99 999 particles bigger than 0 027 micron which is smaller than Hepatitis A B and C The unit provides washing mode rinsing mode mixing mode single point two point circular circle or rectangular path possibility of additional solution mixing during time gap between two work cycles possibility to use microtest plates by different manufacturers ensured by automated plate set up adjusting to different depths of plate wells round bottom plate and strip washing mode possibility of user de
7. MI Medical Biological Research amp Technologies Inteliwasher 3D IW8 Microplate washer for version V 2AW Operating Manual Certificate Contents 1 Safety PreCaUtiONS wisc di bl ie tia a 3 2 General information sss isase A A A A a a ai 5 3 Getting started eaei ee e aal RA dadas abaratar brand dida 6 4 Operation eiii iia a die ead bh it 64 Ache de dk la a ed a hele ee 10 5 Operation closedown 2 2 0 0 eee 13 6 Progdram error Messages Vii tae ae Se Sa eS Bee Oe Rhee ee a 14 7 Specifications site enaa dees He A A OWA PONS PURE AR ORAS ASR 15 8 Maintenance and troubleshooting 0 0c eee 16 9 Warranty Reclamation Information 000000 eee 18 10 GIOSSALY 2544 240444 dr rada a dbeeoeepeera teenais idee dade tedaaed te detains 2 19 11 CGiManking 2 2244 200420 phe tayist on Sadho soem e bee RAR 20 Version 2 04 March 2014 Contents Page 2 Inteliwasher 3D IW8 1 Safety precautions A Attention Please make sure you have fully read and understood the Manual before using the equipment and pay special attention to sections marked by this symbol F Note Paragraphs marked with this symbol contain information about important functions and use of the device GENERAL SAFETY PRECAUTIONS Use only as specified in the Operating Manual provided Protectthe unitfrom shocks and falling After transportation or storage keep the unit at room temperature for 2 3 hours before connecting to th
8. am cycle error messages their description and possible solutions A E TRA HOME ERROR Initalplatiormposiionemor 2 ETRASTEPERROR Prallommenementemar gt 4 HEADMOVEUPERROR Headmovementerror 5 K RESETERROR Emormovingvalveinto initial position 6 K POSITIONERROR__ Errormovingvalveintosetposition____ 7 CANCELED BY OPERATOR _ Program execution is stopped by operator__ Press Run Stop key _ 8 E TRAIL FORERROR Platformmovementerror 9 E TRAIL BACKERROR Platform movementerror J A 1 E RARAS 14 E LANDING ZONEERROR Error movingplateintoworkingzone gt o 19 4CHW Logger error Table 4 Program error messages Repair only by service engineers and trained specialists 6 Program error messages Version 2 04 March 2014 Inteliwasher 3D IW8 Page 15 i Specifications The unit is designed for operation in closed laboratory rooms at ambient temperature from 4 C to 40 C in a non condensing atmosphere and maximum relative humidity 80 at 31 C decreasing linearly to 50 relative humidity at 40 C Dispense system of liquid dosage for each channel separately Minimumdispensevolume ooo 25 ul Maximum dispense volume ooo 1600 ul DISPENSE Incrementa Ad E a 25 ul o Irregular liquid dosage at 300 Ul 2 o max 2 5 or 7 5 ul Allowed residual liquid volume in plate well n n annann max 2 ul Number of wells washed simultaneously 1 0 0 0
9. ble plate wells or the dispensing channel of Dee washing solution is not the manifold ora 5 Ensure presence of liquid in the bottles No 1 2 and 3 fill up dispensed at all needle liquid in a bottle if needed Attention information on liquid ae levels in bottles is shown on the display 5 Absence of liquid in bottles Table 5 Troubleshooting 8 Maintenance and troubleshooting Version 2 04 March 2014 Inteliwasher 3D IW8 Page 17 Symptom Possible cause Action required Obstruction of manifold dispensing channel or a needle During operation needles of the manifold can be obstructed 1 Determine the obstructed needle by checking the underfilling of awell Warning Be careful working with the manifold prevent pricks and injuries caused by needles they may contain dangerous infections 2 Take off the manifold from the device put it down with needles upward Clean the aspiration channel needles with the wiping rod 0 80 mm and clean needles of the dispensing channel with the wiping rod 0 45 mm inserting the wiping rod against stop and removing it 3 After cleaning install the manifold on the device and do the rinsing procedure to ensure the proper operation of the needle 4 In the case of repeated obstruction execute requirements of pp 1 and 2 of this section unscrew the manifold s plugs disconnect the dispensing and aspirating tubes clean the dispensing or aspiration channel with the wipi
10. e changes and startthe unitoperation WASHING PROGRAM WASHING PROGRAM Bottle cycles Second stage rinse shake from bottle 02 bottle 1 2 3 51 42 30 Press RUN button Fig 8 Operating program messages Fig 9 Operating program messages During operation the number of cycles left is displayed fig 7 If the current action has time tracking soaking shaking then the elapsed time is displayed If 4 channel washing solution weight logger is connected to the unit the display during operation shows following massages fig 8 program number active bottle number cycles left and the remaining volume percentage of liquid in the bottles For the waste bottle filled liquid amount is displayed accordingly based on 2 litre bottle volume percentage Pressing the Run Stop key during operation will stop the program and the message Canceled by operator appears on the lower line ofthe display Press the Run Stop key to restartthe washing Note If operation requires washing from one channel parameter On two channels set to NO washing parameters for the second channel are not displayed Respectively if two chamnels are set parameter On two channels set to YES washing parameters for the second channel are displayed and can be adjusted as needed Table 3 Before starting the program for washing from two channels the message to confirm the correct bottle number of second wash appears on the display fig 9 Version 2 04
11. e mains Use only cleaning and decontamination methods recommended by the manufacturer Do not make modifications to the design ofthe unit Before diagnostics study carefully the possibilities and operation procedures of the unit in order to obtain reproducible and credible results Check any unclear issues with the supplier Itis not recommended to leave the operating unit unattended for a long period Change the bottles or connecting tubes only when the unitis switched off In case of doubt about the quality and uniformity of the completed washing program disregard the results obtained and repeat the washing procedure Accuracy of the obtained testing results depends on the quality of the microplate rinsing procedure To assure correctness of the rinsing procedure regularly exercise visual control over reproducibility of liquid volume dosing ELECTRICAL SAFETY Connect only to an external power supply unit with voltage corresponding to that on the serial number label Use only the external power supply unit provided with this product Do not plug the power supply unit into an ungrounded power socket and do not use an ungrounded extension lead Ensure that the switch and external power supply connector are easily accessible during use Disconnect the unit from the mains before relocating it If liquid penetrates into the unit disconnect it from the mains and do not use it until it is checked by a repair and maintenance technician
12. escending Poor contact of the manifold with the holder arm Wipe the golden contacts of the manifold and the holder arm with a piece of cotton moistened with 75 ethanol solution On switching on the device does not fetch liquid from the active bottle Insufficient liquid quantity in the pipe To solve this problem the following procedure should be done Stop the programme Prepare a syringe with 5ml of distilled water Unscrew the hose from the active bottle Press a button System Rinse Using buttons and select number of the active bottle and press the button Start At the moment when the pump begins operation gradually fill the hose with distilled water from the syringe Tighten the hose on the bottle If the pump does not restore performance turn to the service engineer Version 2 04 March 2014 Page 18 Table 5 Troubleshooting 8 Maintenance and troubleshooting Inteliwasher 3D IW8 9 1 9 2 9 3 9 4 9 Warranty reclamation information Warranty reclamation Information The Manufacturer guarantees the compliance of the unit with the requirements of Specifications provided the Customer follows the operation storage and transportation instructions The warranted service life of the unit from date of delivery to the Customer is 12 months exclude items mentioned in the table of Specifications point Contact your local dis
13. f the box between the packaging blocks and the side panels of the carton box place the 2 litre bottle and the half litre bottle in free space between the packaging blocks and the side panels of the carton box Insert the top section into the carton box previously bending it downwards along the perimeter and insert the deflected parts between the walls of the original carton box and packaging blocks so that the device and the rest content of the lower part of the box are fully covered Put the soft foam sheet of grey colour with the smooth side downwards on the resulting horizontal carton surface Putthe rest three bottles and other accessories on the foam sheet Note If 4 channel weight logger is included in the kit place pads under scale cups then place the logger into top section of packaging Cover all the content with another sheet of soft foam material with the smooth side upwards Close the box and seal with duct tape Unit on site installation and preparing for operation Place the unit on a strong horizontal surface which can safely support weight of the unit To provide optimal ventilation ensure 100 mm clearance on each side Operate at ambient temperature from 4 to 40 C and relative humidity up to 80 at 25 C Remove the protecting cover Unpack the plate platform Place the plate platform on the rail fig 2 1 so that the plate holder flat spring faces the rear side of the unit fig 2 2 Magnet on the other
14. fined programs with adjustable parameters 2 General information Version 2 04 March 2014 Inteliwasher 3D IW8 Page 5 3 1 cr 3 2 Getting started Unpacking Remove packaging materials carefully and retain them for future shipment or storage of the unit Note Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage Complete set The set includes No in Fig 1 1 ON DOO BW DY o 11 12 13 14 15 16 17 18 NaMe ssarrerrerroredea Peas de aba oe ne We end vee BOW Yaa Quantity Inteliwasher 3D IW8 microplate washer 00 00 e eee eee eee 1 piece Platform tor plates vosotras Oa eee a ad ee A ee ae oa 1 piece Manitold 222240040 ad arca drid a rd dee ee heed 1 piece Protecting COVED sic wade a mak Rink ea RIA a e 1 piece External power supply unit ac eass taras tadaa aa a a a e eee 1 piece Tubes outside inside diam length 6 3 600 MM 00 cee eee 5 pieces Tube for manifold outside inside diam length 3 2 1 6 400 mm 0 1 piece Tube for manifold outside inside diam length 5 3 440 mm 0000 eee 1 piece Tube for hydrophobic filter outside inside diam 9 6mm 000 0c eee 1 piece Half litre bottle with connectors for aerosol collectiON o o o o o oooo 1 piece 1 litre bottles with sieve filters and connectors for reagents 000000 ee 3 pieces 2 litre bottle with connector for
15. ion Version 2 04 March 2014 Inteliwasher 3D IW8 Page 13 5 1 Operation closedown When the cycle is completed a sound signal will inform thatthe unit stopped the operation Attention Always perform the rinsing cycle using distilled water after finishing the operation at the end of working day This will help to keep the unit in working order and prevent manifold channel clogging 5 2 Press Prime rinse fig 10 1 and the message PRIME RINSE the channel 01 will appear Select the correct channel using and fig 10 2 Press Run Stop fig 10 3 key and the system will perform rinsing cycle Repeat the procedure twice if necessary 5 3 Disconnectthe tube from selected bottle and press Prime rinse key again to dry the tube with air 5 4 After finishing the operation remove the tube from the valve opening to prevent deformation wall glueing of the dosing valve tube To remove the tube press the valve on the side fig 2 4 2 f and stretch the tube a little when pulling it through an opening 5 5 Switch the unit off using mains switch on the rear panel position O OFF 5 6 Unplug the external power supply unit from the mains PRIME RINSE The channel 01 Press RUN button Prime Program rinse parameters Enter Back Run Row Stop 3 2 Fig 10 Prime rinse function Version 2 04 March 2014 5 Operation closedown Page 14 Inteliwasher 3D IW8 6 Program error messages Table 4 shows the progr
16. ird category IPF96 FLAT C are intended for flat bottom well immunoplates Fourth category FastFRAME 2 and fifth category FastFRAME C are intended for Watman Schleicher amp Shuell FastFRAME plates with rectangular wells o1 02 03 04 05 o 07 08 100 Z S i 3 E Bl e 3 8 3 gt I 2 E E l l l l c s 8 2 amp 3 5 0 x x x x a 2 A lt ES irs ts a A Soakings 20 30 30 30 30 30 300 oo 00 Shakings_____ 30 30 _ Dispensedvolume pI 400 400 400 400 400 300 200 300 Aspiratetimems 1200 600 600 600 600 600 600 1000 Finalaspirate ms___ 1200 1200 1200 1200 1200 1200 YES Firstaspirate YES YES YES YES YES NO YES Washbyrows YES YES YES YES YES NO YES Ontwochannels NO NO NO NO YES NO Num of1 wash cycles 01 02 03 05 05 o 1 channel Pp on ot ot aja u Num of2wash cycles o1 2 channel gt S da o Table 1 Initial parameters of all user programs 4 3 Install the plate on the platform Attention When installing a plate the first time or when a different type of plate is installed perform A plate setup to adjustthe manifold lowering depth see paragraph 4 20 Note When wor
17. king with the FastFRAME plates remove the plate holder fig 2 2 Install it back when working with immunoplates 4 4 Use the Enter fig 5 1 key to select category depending on the used plate type Use the and keys fig 5 3 to select required washing program from 1 to 10 Program category and number are displayed in the top right corner of the display fig 4 1 4 5 Press the Program Parameters key fig 5 4 to view the parameters of program In the program first parameter is selected Dispense yes no fig 5 5 4 6 Press the Enter key to select next parameter Version 2 04 March 2014 4 Operation Page 10 Inteliwasher 3D IW8 Plate shaking on the platform during the cycle Firstaspirate 25 1600 step 25 Volume of dispensed liquid Second chan cycles 01 15 Number of washes with second solution Second channel 01 03 Number of second bottle to use Table 2 Programs and their definitions During aspiration the waste fluid bottle is detected automatically 4 bottle The number of the bottle is not specified on the display 4 7 Use the and keys to select necessary value and press the Enter key to change the active parameter Pressing the Enter key automatically saves the setting and activates the next parameter This way you will be able to review and or change all parameters 4 8 Pressing the Back row key fig 5 6 will return to the previous parameter in the program 4 9 Press the Pr
18. lter its IN marking must be facing the bottle 5 fig 11 3 4 11 Connect the Waste bottle to the half litre bottle number 5 fig 3 10 On the rear side of the unit 3 4 12 Connect bottle with buffer 1 to the inlet connector 1 red on the rear side fig 3 3 with the tube fig 1 6 3 4 13 Connect bottle with buffer 2 to the inlet connector 2 black fig 3 5 with the tube fig 1 6 3 4 14 Connect bottle with buffer 3 to the inlet connector 3 white fig 3 6 with the tube fig 1 6 3 4 15 Insert the manifold tube fig 3 2 into the valve opening fig 2 4 Press the valve in the direction of the arrow and hold the valve while stretching the tube and pulling it through the opening Release the valve Fig 3 Assembly diagram Version 2 04 March 2014 3 Getting started Page 8 Inteliwasher 3D IW8 CF 3 4 16 3 4 17 ar 3 4 18 3 4 19 A 3 5 3 5 1 3 5 2 3 5 3 3 5 4 3 5 5 Note Make sure that all connections are secured tightly Install the protective cover ensuring all tubes are covered but not squeezed Place bottles near the unit Note If 4 channel weight logger is included in the kit remove pads from underside of scale cups Place bottles on the 4 channel weight logger according to the numbering Connec
19. ng rod rinse the manifold with the 75 solution of ethanol replace the plugs install the manifold on the device and ensure the proper operation of needles Washing solution is not dispensed into a plate Deformation wall glueing of dosing valve tube due to the long term storage or standstill of the device 1 Remove the tube from the valve 2 In the case of deformation open with fingers the closed part of the dosing valve 3 Insert the tube into the valve opening up to position shown in Fig 2 4 Note in order to release the tube press the valve on the side and slightly stretch the tube pulling it through the opening Wear or damage of the valve tubes and the pump The connecting tubes are worn or damaged during exploitation Turn off the device and have it checked by a specialist Only service engineers and trained specialists are allowed to replace the tubes Volume of residual liquid in a well exceeds the admissible value 2 mkl 1 Depth of the manifold immersion is not determined 2 Obstruction of the manifold aspiration channel or a needle 1 Perform well depth measurement in the automatic mode 2 Check if the aspiration channel and needles are not obstructed If yes do their cleaning see the section Obstruction of manifold dispensing channel or a needle in this Table If it does not help turn off the device and have it checked by a specialist The manifold is not d
20. ogram Parameters key again to exit parameter view and change mode and save the program 4 10 Press the Esc key fig 5 7 to exit parameter view and change mode without saving 4 11 Usethe Run Stop key to start the program WASHING PROGRAM IPF96 U V C IPF96 FLAT 2 IPF96 FLAT C FastFRAME 2 FastFRAME C PLATE SETUP ENTER to select Fig 4 Program selection 4 1 7 5 Prime Program rinse paramete Enter Esc Aspirate C C Shake Dispensing rate Aspirate rate Soak llimit s Back al Run Row Stop 2 Fig 5 Control panel 4 Operation Version 2 04 March 2014 Inteliwasher 3D IW8 Page 11 4 12 4 13 4 14 4 15 4 16 4 17 4 18 WASHING PROGRAM WASHING PROGRAM Bottle Number of rows cycles shake Press RUN button Fig 6 Pre set rinsable row number Fig 7 Operating program messages If washing of less than 12 rows on a plate is needed press the Rows key before starting The following message appears on the display fig 6 Select necessary number of rinsable rows using and keys Pressing the Run Stop key will save changes and start the unit operation Ifoperation requires washing from two channels parameter On two channels setto YES the message to confirm the correct bottle number of second wash appears on the display before starting the program fig 9 Select necessary bottle number with buffer using and keys and press the Run Stop key It will sav
21. ophobic filter For bottle 5 BS 060102 S44 Filter complete set Filter weight tube BS 060102 S01 Silicone tube set 6 pcs BS 060102 S39 Accurate within 10 Biosan is committed to continuous improvement of the unit s properties and quality and reserves the right to alter unit s design and specifications without additional notice Version 2 04 March 2014 7 Specifications Page 16 Inteliwasher 3D IW8 8 1 8 2 8 3 8 4 8 4 1 8 4 2 8 5 8 6 A 8 7 Maintenance and troubleshooting If the unit requires maintenance disconnect the unit from the mains and contact your local Biosan representative or Biosan service department All maintenance and repair operations must be performed only by qualified and specially trained personnel Do not use non conforming parts for repair The manufacturer provides all necessary services and spare parts To order necessary services and parts please contact your supplier Maintenance checks The following checks can be done by operator Daily maintenance clean the surface of the device from liquid droplets and contamination perform the rinsing cycle twice using distilled water after finishing the operation see point 5 Monthly maintenance Cleaning with 75 ethanol e mounting contacts on the manifold mounting surface ofthe plate platform and plate holder spring Ethanol 75 or other cleaning agents recommended for cleaning of laborator
22. rming one by one the program parameters command to setthe number ofwashable rows command to stop the washing program 10 Glossary Inteliwasher 3D IW8 11 CE Marking The C marking affixed to the equipment indicates that the equipment meets the requirements of the following Directive s RoHS Directive 2011 65 EU RESTRICTION OF HAZARDOUS SUBSTANCES WEEE Directive 2002 96 EU and 2012 19 EU WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT EMC Directive 2004 108 EC ELECTROMAGNETIC COMPATIBILITY Applied standards EN 61326 1 Electrical equipment for measurement control and laboratory use EMC requirements General requirements Low Voltage Directive 2006 95 EC ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS Applied standards EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General requirements 11 CE Marking Version 2 04 March 2014 Inteliwasher 3D IW8 Page 21 Biosan SIA Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 http www biosan lv Version 2 04 March 2014 Inteliwasher 3D IW8
23. s potentially dangerous biological materials can be used When working with such materials always use protective clothing and eye protection Always have the protective cover installed during operation Version 2 04 March 2014 1 Safety precautions Page 4 Inteliwasher 3D IW8 2 General information Inteliwasher 3D IW8 series microplate washer is designed for washing various types of standard microtitre plates microstrips and microarrays on FastFRAME rectangular well shape It is suitable for washing wells with different bottom shapes flat U shape and V shape The unit is fully programmable ensuring multi step solution ripening aspiration aspiration combination of aspiration liquid dispensing and soaking as well as soaking cycle during a particular period of time The unit has 50 programs divided into 5 following aspiration categories see scheme below D Type 1 1 0 1 9 IPF96 U V is intended for U shape and V shape immunoplates 1 point aspiration 2 Type 2 2 0 2 9 IPF96 FLAT 2 is intended for flat bottom shape immunoplates 2 point aspiration Type 3 3 0 3 9 IPF96 FLAT C is intended for rectangular shape immunoplates full circle aspiration direction 4 Type 4 4 0 4 9 FastFRAME 2 is intended for multi slide plate with rectangular wells Type 5 5 0 5 9 FastFRAME C is intended for multi slide plate with rectangular wells T
24. t the RS 232 with the cable to the plug connector on the rear side of the unit fig 3 7 Attention Make sure that the power switch of the unit is in O Off position before connecting power cable to the mains outlet Switching on Connect the external power supply to the power socket fig 3 8 on the rear panel of the unit Connect the power cord to the external power supply unit fig 1 16 Connect the external power supply unit to the grounded power socket Switch ON the unit position I using the power switch on the rear panel When switched on the unit performs full initialisation cycle and displays the message Power on reset Note Fullinitialisation cycle takes not longer than 5 seconds 3 Getting started Version 2 04 March 2014 Inteliwasher 3D IW8 Page 9 4 Operation 4 1 Before starting plate washing Fill the rinsing liquid bottle number 3 with distilled water or appropriate cleansing solution Fill the necessary bottles number 1 and or 2 with washing solutions 4 2 Initial parameters of all programs are given in Table 1 All values are adjustable Ranges descriptions of program parameters are shown in Table 2 All programs are divided into 5 categories of 10 adjustable programs Each category corresponds to a different plate well configuration and subsequently aspiration mode fig 4 First category IPF96 U V is intended for U shape and V shape well immunoplates Second category IPF96 FLAT 2 and th
25. tributor to check availability of extended warranty If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the local distributor address Please visit www biosan v Technical support section to obtain the claim form The following information will be required in the event that warranty or post warranty service comes necessary Complete the table below and retain for your record Model Inteliwasher 3D IW8 Serial number Date of sale Inteliwasher 3D IW8 Version 2 04 March 2014 Page 19 10 Glossary Version 2 04 March 2014 Page 20 O ON DO o 12 Rinsing mode Mixing mode Single point aspiration Double aspiration Strip washing mode Dispensing Waste bottle Plate setup Run mode Enter Rows Stop mode plate washing mode consisting of consequent dispension and aspiration to from wells provides mixing of solution in wells by shaking the platform plate washing mode which provides solution aspiration from the center point ofa well plate washing mode which provides solution aspiration consequently from two opposite points of a well plate washing by rows filling wells with a set solution volume the bottle for collecting the aspirated liquid procedure for automatic measurement of well depth command to startthe washing program in program setup mode this command is used for confi
26. y equipment can be used for cleaning and disinfection ofthe unit Filter replacement fig 11 It is recommended to change the hydrophobic filter once in six months in particular cases e g at intensive operation once in three months to order the filter you have to know the product identification number see the table in Specifications chapter Disconnect the filter from outlet tube remove the filter insert a new filter into the socket and tighten it Attention Maintain mounting of the filter according to is Fig 11 The marking IN should be located on the side of the inlet tube facing to the bottle Fig 11 Filter mount Troubleshooting Symptom Possible cause Action required Manifold dosing error 1 Poor contact between 1 Ensure proper connection of the bottle with the device or the bottle hose con Volume of washing nector and the device 2 Check if the hose is overbend and straighten it if necessary or solution does not 2 The hose is overbend 3 Check if the sieve filters in bottles No 1 2 and 3 are clogged correspond to the set i E F volume dosing 3 Obstruction of sieve 4 Check if the dispensing channel of the manifold or needles is unevehness is filters not obstructed If yes perform cleaning see the section b dal th Obstruction of manifold dispensing channel or a needle in nl Ai 4 Obstruction of this Ta