Cell Assistant - Dynamometer Test Automation Software

image

Contents

1. 1 Hardware Requirements 1 Installation of Cell Assistant 2 LIGENSING ETT 3 Evaluating Cell Assistant 3 Chapter3 Getting Started Disable the Watchdog Feature 1 Creating aTestSystem 2 Hardware Devices EEN 3 Channels Taba cec tet eer c recte e ret ud uet Eie EE Vu 3 TestPlan Tab 4 Litt TAD RE T 4 Data Files Tab RH hn 4 CONDITIONS c fon E A 4 Adding Virtual Instrument Panels VIP S 5 Chapter4 Hardware Devices Adding a Device 225 5 E ERURERODA TURCA RULES ROCA TCRCRASEUE CREE E 2 Deleting a Device iiir so kar rr RE RR ER RR RR 2 Configuring a HEIEREN EEN 2 Serial Port Configuration ns oor ENEE EE A ae du nement 3 Network Configuration 4 Device ContiguratiON need ce amend edn eink edn e EE akon mavens 5 Device DIAGNOSIICS coe coh Ee Eer gg reg Ee rege eg 6 Disabling a VEER 7 TOC 2 TABLE OF CONTENTS Chapter 5 Chapter 6 Chapter 7 Channels Virtual vs Physical Channels 2 Sorting and Filtering the List 2 Exporting amp Importing Channels 3 Channel Types EE 3 Creating Virtual Chann
2. 4 Controlling Limits in a TestPlan 5 Linil 5609 EEN 7 ThisLimit ODIEGU ANR 9 DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc TABLE OF CONTENTS Chapter8 Data Files Creating a Data File Format 2 Organizing Channels 2 Exporting amp Importing Data File Formats 2 Data File CGontents 3 Using Data File Formats in a TestPlan 4 DEM EE dE EE cares 4 1088 5 Sano Eod EE 4 E eee ae cette LL LUI ILI LI IL LE 5 DIAMLOQGING ssec exces exero pt ene ex cxx epee ened CE CER E NER 5 yrs More celo mtem 6 Brel CEET 6 L ogRenod 2 24 Te dida RE Na TN Ee 6 ISLOQGING EE 7 EI LS LP ganda E T E E aetna 7 FOFCOEHEJ EE 7 WriteChannelNaMmes ccc cece even eee RR x xe exu nk EE 8 WriteGhahielUflllS ee 8 WriteChannelHeader 8 Chapter9 Virtual Instrument Panels Microsoft Visual Studio Express 2012 or similar 2 Greaunga VIP sais ire a Ra rra rkrerakRra 2 VIPCONTROLS OCX Eer EE SEN 4 Network MIER 5 Using VIP s in a TestPlan EEN 6 VIP Driver ee 7 TT 7 Chapter 10 DSBasic Dialog Editor Grealingadlalgg 2 22222222 002002 022c0 0 020 1 Launching a dialog 2 Interacting with a dialog
3. 2 DyneSystems Cell Assistant TOC 3 DPD 008 02 e Copyright DyneSystems Inc TABLE OF CONTENTS Chapter 11 Calibration Calibration Equation Calibration Types Calibration Procedure Calibration Database Exporting amp Importing Calibration Database Chapter 12 Preferences ADDOSIGNOB 2 225232 523232 25232 ana ana sazasalis ras FeatlleS iisssuosussausussuussupuuususeusosussAvuA Es Watchd0g eege EENS ee onum Chapter 13 Miscellaneous Data Folder Structure iiisrsasas a a ka ARA RA ARA RATER ERA Backing Up Dald cosvesebkskEEXEXEX XREYa EE EE Pd5sWUIUS 22 20 222292222 os oe zs ca oe os oe 2 2G Qu MELLE Stat s Bd 4 55 dee de eeh dree dee dee dreet Chapter 14 System Channels TOC 4 DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 1 Introduction Cell Assistant is a very powerful data acquisition and control system providing all standard components of a full featured data acquisition subsystem synchronized data acquisition from multiple devices limit detection recorded data files channel calibration a flight recorder etc Device drivers are provided for connection to a variety of devices such as closed loop dynamometer controllers programmable logic controllers PLC s emissions analyzers f
4. 1 0 CHAPTER 3 Getting Started This chapter provides an overview of Cell Assistant providing the minimum steps to quickly create a TestSystem and begin executing a test Disable the Watchdog Feature Launch Cell Assistant by double clicking the desktop icon When initially launched an error dialog will appear regarding the initialization of the watchdog COM port A watchdog device is an important safety mechanism in any test cell and is described elsewhere in this document To initially proceed with Cell Assistant the watchdog must be disabled as follows Click OK to dismiss the warning dialog Select File then Password from the main menu Enter the default configuration password i e cfg and click OK Select File then Preferences from the main menu Click the Watchdog tab Select Disabled in the Serial Port drop down list rd OO oO 5 O DO Click the Apply button Enter your initials and click OK to log this change to the watchdog settings Click OK to dismiss the Program Preferences dialog Exit Cell Assistant CHAPTER 3 Getting Started 2 0 Creating a TestSystem All information regarding your overall testing system are maintained in a single file This information includes a list of installed devices data channels limits etc TestSystem files have a ca2012 file extension Unless the hardware configuration of a tes
5. C DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc APPENDIX 1 System Channels F to C This function converts a temperature in degrees Fahrenheit to a temperature in degrees Celsius Temperature C T 32 1 8 Input Description T Temperature F C to F This function converts a temperature in degrees Celsius to a temperature in degrees Fahrenheit Temperature F T 1 8 32 Input Description T Temperature C Pounds to Kilograms This function converts a weight in pounds Ib to a mass in kilograms kg Mass W 0 45359237 Input Description W Weight Ib Kilograms to Pounds This function converts a mass in kilograms kg to a weight in pounds Ib Weight M 2 2046226 Input Description M Mass kg PSI to Inches of Mercury This function converts a pressure in pounds per square inch PSI to a pressure in inches of mercury in Hg at 0 C Inches Hg P 2 03602 Input Description P Pressure psi DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc APPENDIX 1 System Channels Inches of Mercury to PSI This function converts a pressure in inches of mercury in Hg at 0 C to a pressure in pounds per square inch PSI PSI INHG 0 0 491154311 Input Description INHG Pres
6. Channel Modify dicEngineCoolant lempFault Source Device Channel m Digital Input C333 D Cancel Sample Rate i Samples sec Invert Logic Display Information ON Text OFF Text 10 0 Delete Rename Channels Virtual channels can be deleted from the TestSystem and or renamed as needed by clicking the Delete and Rename buttons respectively This should be done with great caution It is generally safe to do so during the early stages of TestSystem development however it is a bit more troublesome later on after the channels have been bound to limits included in data files referenced in various TestPlans etc Note In general Cell Assistant will attempt to repair update the usage of a channel when it is deleted or renamed Unfortunately it can NOT repair update all uses e g references in DSBasic TestPlan code Ultimately all unfixable uses will generate errors when data acquisition is started and or a TestPlan is selected and run At that time the TestSystem developer must manually make all required repairs DyneSystems Cell Assistant Delete Rename Channels DPD 008 02 e Copyright DyneSystems Inc 5 11 CHAPTER 5 Channels 11 0 Accessing Channels in a TestPlan The value of any channel may be accessed at any time by a running DSBasic TestPlan As explained in other chapters each virtual channel becomes an instantiated object to a running DSBasic Tes
7. Chapter 3 Getting Started 2 1 Hardware Devices Tab The first step in creating a TestSystem is to install device drivers for all attached devices All devices serial port or network based should be connected to the host computer and powered up Add a driver instance for each connected device Although rarely necessary multiple devices of the same type and hence multiple instances of the device driver are allowed A set of device configuration dialogs are available for each device These dialogs are used to configure the serial port and or network communications settings as well as other device specific configuration Simple diagnostic dialogs are also available to test communications and overall functionality of each connected device Do not proceed to the next step until you have successfully established communications with each device 2 2 Channels Tab The second step is to create virtual channels that exchange data with the various installed devices Some channels may be data channels e g thermocouple readings voltage readings PLC 1 0 bits etc while others may be device control channels e g On Off and Speed Torque mode commands to a dynamometer controller Other channel types such as internal timers averages of other channels computed channels etc can also be created If your system has been completely specified and fully designed all channels can be created at this time Unfortunately this situation rarely occurs Plu
8. Formatl ForceEntry Your string goes here The following examples are valid uses of the ForceEntry method Formatl ForceEntry Operator Name Tom Smith Formatl ForceEntry Engine Serial Number is XY01234 Formatl ForceEntry Test aborted due to coolant over temperature DyneSystems Cell Assistant Using Data File Formats in a TestPlan 8 7 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 8 Data Files 5 11 WriteChannelNames This method adds a header record listing the names of all channels included in the currently open data file format This header line is exactly the same as the header line recorded by the Open method when a data file is initially opened or created This method is typically used to periodically re write all channel names in order to improve the readability of the data file It can also be used to add channel name information that may have been previously suppressed in the Open method with the NoHeader flag The syntax of the WriteChannelNames method is shown below Format1 WriteChannelNames 5 12 WriteChannelUnits This method adds a header record listing the configured units of all channels included in the currently open data file format This header line is exactly the same as the header line recorded by the Open method when a data file is initially opened or created This method is typically used to periodically re write all channel units in order to improve the readability of the da
9. Thus the limit will not trip and the border will not change color Similarly a limit can trip in Cell Assistant which causes the border color of all affected meters to change color The actual value of the channel may then change which causes the needle to now point to a GREEN portion of the scale But the Cell Assistant limit handler in DSBasic code may still be processing the limit and has not yet allowed the limit trip state to return to normal Thus the border colors remain in their tripped state 3 0 VIPCONTROLS ocx The VIPCONTROLS ActiveX control provides a set of meters gages etc allowing high quality user interfaces to be created with absolutely NO programming whatsoever The controls can be placed on a Visual Basic form and then totally configured using standard property pages Each of these controls is briefly described below The details of each control property are not discussed since most have an obvious affect on the controls operation and or appearance Control Icon Description Analog Meter e A simple needle type meter that continuously displays the value of any analog channel Digital Meter Bar Meter At A simple numerical readout of any analog channel Another popular meter style used to continuously display the value of any analog channel Text Meter The Text Meter has three modes of operation depending on the configured Input Source 1 If connected to a text channel the m
10. 7 4 Limit Handler Procedure DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 7 Limits Shown below is the default limit handler procedure that is automatically created when the Add button is clicked on the Limits tabbed page Function LIM MyLimit As Integer If ThisLimit IsTripped Then TODO Add code to handle the onset of an edge triggered limit or a level triggered limit here Else TODO Add code to handle the offset of an edge triggered limit here End If LIM MyLimit 0 End Function The code comment fields clearly show where the TestSystem programmer must add additional code There are two general sections where code should be added one section to process the onset of a limit trip and another to process the offset i e clearing of a limit trip condition As stated previously typically most limit hander DSBasic code will be added to the onset processing section Return Values A limit handler function MUST return a value before exiting This return value determines what the limit task will do when the limit handler has finished execution The following table lists all possible return code values Return Value Action 0 TestPlan continues to execute 255 Stop the currently running TestPlan All other values Ignored reserved for future use A limit handler should never attempt to stop a running TestPlan by executing the End statement instead it shou
11. When you run your first TestPlan the file FlightRecO0 csv will be created When the second TestPlan is run the file FlightRecO1 csv is created When the 100th TestPlan is run FlightRec99 csv is created Finally when the 101th TestPlan is run a new FlightRecOO csv is created which will replace the previous one This sequence continues forever When viewing the files in the FlightRecorder subdirectory always sort the file list by creation date or last modified date in order to determine which flight recorder file was created last and hence is the one from the most recent TestPlan run Flight Recorder files employ the same format as Data Files which are described later in this manual But unlike Data Files the contents of Flight Recorder files cannot be configured A Flight Recorder file contains snapshots of ALL TestSystem channels taken at the configured Flight Recorder log rate Also whereas Data Files can be opened closed started and stopped under the complete control of a running TestPlan Flight Recorder data logging starts when a TestPlan starts and stops when the TestPlan stops Note that in almost all debugging situations a regular TestPlan Data File is a better choice for data logging because it can be configured to log only the channels of interest and logging can be selectively started and stopped under complete control of the running TestPlan The Flight Recorder task is designed to be a backup mechanism in situation
12. be specified by the DSBasic script when the data file format is opened and activated Check the Include Limit Exceptions checkbox if you want the limit tasks to automatically record limit exceptions in the open data file Note that your limit handler code can also log custom limit handling exception messages Click the Done button to save the new data file format Click the Modify button to re open the data file format and begin adding and organizing all channels to be logged by this data file format Organizing channels is explained below Note Anew data file format can also be created by duplicating an existing format Select the data file format to be duplicated and click the Duplicate button Modify the format as needed enter a new format name and click the Done button 2 0 Organizing Channels When a data file format is enabled for modification all available channels are alphabetically listed on the right most list box This list will ONLY contain channels not already included in the data file format The various Add and Remove buttons are used to transfer channels back and forth between the Included list and the Available list Note the Add Above and Add Below buttons require an insertion point to be defined in the Included list These buttons are only enabled when a single selection exists in the Included list Multiple selection is supported in both channel lists Simult
13. hardware CHAPTER 2 Installation 3 0 Installation of Cell Assistant A file similar to the following will be provided to you via CD e mail download etc File Name Install CA2012 2 00 0019 exe or similar In Windows Explorer double click this file to start the installer Then follow the installation instructions as they are presented The most important installation decision is the location of the installation data folder For simplicity and ease of service please keep the default installation data folder i e C CA2012 Also let the installer place a Cell Assistant icon on the desktop making it easier to launch this product Note Cell Assistant uses older style help files i e hlp files Unfortunately WinHlp32 exe is no longer included in Vista and Windows 7 distributions Additionally these OS s will interrupt the installer when they detect the installation of a hlp file Fortunately the interruption consists of a pop up dialog directing you to a web site where WinHIp32 exe can be downloaded and installed Follow the links and install WinHIp32 exe for the correct OS i e Windows 7 32 bit or 64 bit version 2 2 Installation of Cell Assistant DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 2 Installation 4 0 Licensing A full product license is required to use all of the features of Cell Assistant A license consists of a license file that must be installed on the host computer If n
14. of the computer If the remote computer exists on a local network you can also click the Browse button to get a list of available computers and then select the desired computer graphically The TCP IP Port must match the TCP IP port that is currently being used by the Network VIP Data Server that is running on the remote Cell Assistant computer Typically the default value should be specified If Cell Assistant is running on the specified computer and it is configured to support network connections this control will immediately connect to the remote computer When the ComputerSelect control is first placed on a form it will read Not Connected Once a connection is established the controls appearance will change to a progress bar providing visual feedback of network activity when the VIP is run At this point you can continue to develop and or run VIP s in the usual manner Keep in mind you are now connected to a remote Cell Assistant computer via a network connection that may have long network latencies These delays are usually quite tolerable if running entirely in a local Intranet however these delays can be longer if the remote computer is farther away in a network sense Note The most efficient process to develop a network VIP is to fully develop the VIP on the Cell Assistant local computer When done simply add and configure the ComputerSelect control and the VIP can now be moved to another computer 5 0 Using VIP s in a
15. the device manual for these values They are typically configurable in the device as well thus you may need to contact your IT department for help in establishing a valid IP address that will not conflict with other devices on your Local Area Network The default Port value specified by the device vendor can typically be used as is Note Changes to communication settings are activated when the configuration dialog is closed therefore close then re open the configuration dialogs whenever a communication setting is modified Device Setup MW 100 Diagnose Inputs Diagnose Outputs Configure Setup Network r Sampling IP address ER t Rate 10 D Hz Port 3431 8 Default state Enabled 4 4 Configuring a Device DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 4 Hardware Devices 3 3 Device Configuration Many devices are configurable For example the number location and type of installed modules in a data acquisition device must be configured in the device driver Similarly the I O address of bits and registers in a Programmable Logic Controller PLC must be configured in the device driver A sample configuration page for a PLC is shown below The device configuration pages for all available device drivers are not documented here Assuming operator familiarity with the device the configuration fields presented in the respective device configuration pages should be obvio
16. the other pages e g Channels Calibration Data Files etc manage the data acquisition functionality of a TestSystem the TestPlan page manages the control functionality TestPlans control the entire flow of any test TestPlans are written in the DyneSystems Basic DSBasic programming language DSBasic is a powerful scripting language similar to the Microsoft Visual Basic programming language But it also incorporates many language extensions specifically designed for data acquisition and control Using these language extensions a running DSBasic TestPlan can access channel data as well as control the operation of all connected devices L JestSystem 40CFRPart86_TransientTesting ca2012 TestPlan Channels Limits Calibration Data Files Hardware Devices r Top Level TestPlans EngineMap ManualDAQ Edit TestSequenceManager rias jentTest Run Add r TestPlan Properties Name Flight Recorder Log Rate and Duration 1 0 Hz for 10 Minutes r Edit Other TestPlans GLOBAL GLOBAL CALCULATED LIMIT Group 1 Group 2 Functions Handlers CHAPTER 6 TestPlans 1 0 Top Level TestPlans Any TestSytem may contain one or more TestPlans TestPlans can be large e g EPA emissions tests or small e g a simple report generating utility Each TestPlan consists of one Top Level TestPlan A new Top Level TestPlan can quickly be created by clicking the Add button entering a uniqu
17. user interfaces These graphical controls are designed to work exclusively with Cell Assistant and require absolutely no Visual Basic programming experience As long as Cell Assistant is launched and data acquisition has been started each control has full access to all configured data channels and can easily be connected to any channel Ultimately each created form i e VIP is compiled into an executable exe file These VIP executable files can be launched and closed as needed by a running Cell Assistant TestPlan using just a few lines of DSBasic code The details of creating VIP s using Microsoft Visual Basic are fully described later in this document DyneSystems Cell Assistant Adding Virtual Instrument Panels VIP s 3 5 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 3 Getting Started 3 6 Adding Virtual Instrument Panels VIP s DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 4 Hardware Devices The Hardware Device page manages all devices in the TestSystem Installing connecting and configuring each device is always the first step in creating a new TestSystem For each installed device verify that a corresponding device driver is listed on this page If not contact Dyne Systems immediately The standard Cell Assistant installation contains a minimal set of drivers for the most commonly used modern devices however many other less popular drivers are available Worst case a new dr
18. 43 Correction Factor Relative Humidity 150 3046 1 Correction Factor F to C C to F Pounds to Kilograms Kilograms to Pounds PSI to Inches of Mercury Inches of Mercury to PSI Inches of Mercury to kiloPascals LB FT to Newton Meters Newton Meters to LB FT Horsepower to Kilowatts Kilowatts to Horsepower Brake Specific Fuel Consumption Horsepower Multiplication 2 channels Calculation Inputs Ir d Barometric Pressure kPa Se Relative Humidity Pe Dew Point C fo Intake Air Temperature C Format Cancel Engineering Units Decimal Places 0 Y Use this dialog to select the conversion factor equation and or function the newly created system function should implement Based on this selection drop down lists for each of the appropriate inputs are displayed Select the appropriate input channels as needed System Function Channels DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 5 Channels Note f one or more of the required input channels have not yet been created those inputs may remain un configured at this time They can be added and or modified later on from the Channels tabbed page Note All system functions are described in an Appendix at the end of this document 7 0 TestPlan Calculation Channels Like most of the other channel types TestPlan Calculation channels require no immediate additional configuration when initially crea
19. Click the appropriate button in the Edit Other TestPlans group to access these components GLOBAL Subroutines To facilitate better TestPlan organization two global TestPlans are available All DSBasic code in GLOBAL TESTPLAN 1 and GLOBAL TESTPLAN 2 are automatically compiled and executed along with every Top Level TestPlan These TestPlans can be used as a repository for DSBasic Other TestPlans DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 6 TestPlans 2 2 2 3 subroutines that may be used by more than one Top Level TestPlan They can also be used for any general subroutine in order to reduce the size of a Top Level TestPlan that is getting large and perhaps difficult to manage CALCULATED Functions The CALC FUNCTIONS TESTPLAN contains the DSBasic code implementation of each TestPlan calculated function channel See the Channels section of this manual for more information on creating TestPlan calculated functions A code stub for each channel is created automatically when the channel is created The DSBasic code for these functions should be very short and concise i e make the required channel calculation and exit the function Note The CALC FUNCTIONS TESTPLAN should NOT contain any other DSBasic code other than the TestPlan calculated functions LIMIT Handlers The LIMITS TESTPLAN contains all limit handling functions for each defined limit See the Limits section of this manual for
20. ER 13 Miscellaneous Folder Use Calibrations Contains the main calibration database file CalibrationDatabase db This is also the default folder where all other exported snapshot files of the calibration database are saved e g cal 0001 csv cal 0002 csv etc DataFiles This is the folder where running TestPlans will store all data log files A running TestPlan can specify any destination folder to save a data log file however this is the default folder when no destination folder is specified which is typical for most TestPlans DeviceSettings Contains several INI files containing all device settings Communications INI contains all serial and network settings for all configured devices GeneralSettings INI contains all other settings for all configured devices Other device specific INI files may also exist Exports This is the default folder when exporting channels limits and data file formats to a csv file FlightRecorders All flight recorder csv files are stored here The TestSystem developer cannot change this folder IniFiles Any DSBasic TestPlan can create application specific INI files to store various test parameters test results etc These files can reside anywhere on the local computer however this folder is provided as a convenient storage location SpreadSheets This folder is provided as a convenient storage location for Microsoft Excel spreadsheet files Sever
21. ES e ao Inc Midwest amp Dynamatic Dynamometers Cell Assistant Dynamometer Test Automation Software USER MANUAL www dynesystems com DPD 008 02 No part of this manual may be reproduced or transmitted in any form or by any means including photocopying recording or using information storage and retrieval systems for any purpose other than the purchaser s own use without the express written permission of Dyne Systems Inc 92015 by Dyne Systems Inc All Rights Reserved Any other product names and services identified in this manual are trademarks or registered trademarks of their respective owners No Such uses or the use of any trade name is intended to convey endorsement or other affiliation with Dyne Systems Inc Contact Information Shipping Address W209 N17391 Industrial Drive Jackson WI 53037 Mailing Address W209 N17391 Industrial Drive Jackson WI 53037 Toll Free Phone 800 657 0726 Fax 262 677 9308 Web www dynesystems com E Mail sales dynesystems com Document Revision History Version Date Comment 01 03 MAR 2012 Initial Release 02 01 NOV 2015 First Major Update Product Software Revisions This document is up to date with respect to the following versions of product software Cell Assistant Version 2 00 Build 0019 Table of Contents Chapter 1 Introduction Chapter 2 Installation Operating System Requirements
22. Each control is designed to work interactively with Cell Assistant allowing the user to modify the appearance and operation of control merely by changing the control properties CHAPTER 1 Introduction DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 2 Installation 1 0 Operating System Requirements Cell Assistant runs under Microsoft Windows XP Vista and Windows 7 2 0 Hardware Requirements Cell Assistant will run on any personal computer running any of the previously listed operating systems Additional hardware may also be required as described below Ahigh performance multi port RS 232 serial port board typically needs to be installed as many devices still communicate via an RS 232 port The high performance serial port card provides two benefits First of all it provides 4 or 8 additional serial ports whereas a typical personal computer provides at most one or none Secondly the high performance serial ports utilize extremely large hardware buffers 4KBytes guaranteeing no lost or dropped data bytes during data acquisition Many devices now provide a network interface In this case a 2nd Network Interface Card NIC must be installed To support multiple network based devices a network switch is also required If Dyne Systems is providing your computer all required additional hardware will be pre installed and configured else contact Dyne Systems for recommendations for all
23. LimitSetNames Retrieve names of all available limit sets DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 7 Limits 7 0 ThisLimit Object Prior to executing a TestPlan the DSBasic compiler instantiates a limit object for each defined limit The name of each DSBasic limit object is the same as the configured limit name thus all executing DSBasic code TestPlan code calculated function code limit handler code etc can access and control any specific limit using the respective limit object name A problem arises when a generic limit handler is used for more than one limit which is typical This shared limit handler may need to disable the limit alter the high or low limit values log a message etc just as any other limit handler would typically do thus from within the context of the executing limit handler procedure the executing code requires a means to determine exactly which limit object has caused the shared handler to execute The ability to use a DSBasic limit handler for more than one limit is provided by the ThisLimit object as explained below Note Once a limit handler contains references to a specific limit object it can no longer be used as a shared limit handler for any other limits The ThisLimit objectis identical to a limit object Most but not all of the methods that are available for a limit object are also available for the ThisLimit object This o
24. TestPlan Only a few lines of DSBasic code are needed to launch a Virtual Instrument Panel as shown below The full path to the VIP executable file as well as the VIP main window title must be known The window title is needed in order to check if the VIP is already launched e g it may have been externally launched by an operator using Windows Explorer and or it was not properly closed during a previous TestPlan execution Sub Main Title and path to my VIP MyVipTitle Main VIP MyVipPath C NCA2012NVIPsMMainVIP exe Launch VIP if not already running If AppFind MyVipTitle Then id Shell MyVipPath ebNormalNoFocus End If End Sub Using VIP s in a TestPlan DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 9 Virtual Instrument Panels Similarly the previously launched VIP can be closed using the following lines of DSBasic code Sub Main Title of my VIP MyVipTitle Main VIP Close VIP if needed If AppFind MyVipTitle lt gt Then AppClose MyVipTitle End If End Sub Note Allofthe DSBasic function calls used in the above examples i e AppFind AppClose and Shell are fully described in the on line DSBasic reference manual 6 0 VIP Driver Each meter gauge button etc in a VIP is connected to i e bound to a virtual channel in a Cell Assistant TestSystem And virtual channels are created from the various physical device channels provide
25. ables this limit which is typically done immediately Note Most limits are configured to be Edge Triggered limits with a limit handler procedure that only processes the onset of a trip 2 2 Trigger Range The Trigger Range property determines how the limit task evaluates the current value of the Monitored Channel The following table describes the various Trigger Range configurations Depending on the specified type one or both of the limit threshold values must be specified Note The Low Limit and High Limit threshold values can also be dynamically modified by a running TestPlan as explained in a later section 7 2 Configuring a Limit DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 7 2 3 2 4 DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Limits Trigger Range Limit will trip if Low Limit High Limit Low Monitored Channel value Y Low Limit value High Monitored Channel value gt Z Y High Limit value In Range Low Limit value lt Monitored Y Y Channel value lt High Limit value Out of Range Monitored Channel value lt Y Y Low Limit value OR Monitored Channel value gt High Limit value Limit Priority Cell Assistant provides two limit monitoring tasks a high priority task and a low priority task Check the High Priority checkbox to have the selected limit mon
26. ages on a DAQ device Command setpoints to a dynamometer controller Digital Input Boolean Binary status values e g PLC Input bits Digital Output Boolean Binary output values e g PLC output relays Simple On Off commands sent to many devices Text Input String Retrieve string responses from simple ASCII based devices Text Output Device Status Input String Integer Send commands to simple ASCII command based devices Send multi valued state commands to a device e g speed torque position mode control Device Control Output Channel Types Integer Retrieving multi valued status values from a device DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 5 Channels Other channels Channel Type Representation Description Average Double precision floating point Computes the windowed average of another analog input channel The width of the averaging window in seconds must be specified Typically used to smooth filter noisy analog readings TestPlan Calculated Double precision floating point These channels are implemented using the DSBasic scripting language The equations can be as simple or complex as needed and can use other channel values as inputs System Function Double precision floating point System functions are built in functions conversions and other formula
27. al standard Cell Assistant applications provided by DyneSystems rely on the use of spreadsheets They will be stored in this folder TestSequences The Test Sequence Manager TSM is a standard Cell Assistant application developed by DyneSystems The TSM relies on the use of test sequence files i e tsf files They will be stored in this folder TestSystems All TestSystem files i e ca2012 files should be saved here TransientTesting Data Folder Structure DyneSystems has developed a set of TestPlans to perform EPA 40CFR Part 86 Engine Mapping and Transient Cycle tests This folder contains many other tools to support these applications as well as provide data storage for the various test results DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 13 Miscellaneous Folder Use VIPs TransientTesting Virtual Instrument Panel VIP executable files should be stored here VIP s are created using the latest version of Microsoft Visual Basic and or Microsoft Visual Studio All project files are maintained elsewhere typically in default project folders created by the specified visual development tools As VIP s are compiled the final executable files should be placed into this folder Note A VIP Relocator tool is available to simplify the copying of all required files as well as to eliminate file copying errors See the Virtual Instrument Panel section for inf
28. aneously hold down the CTRL or SHIFT keys to select multiple channels and or contiguous blocks of channels Finally all channels will be logged in the exact order shown in the Included channel list Modifications and corrections to the channel logging order can be made using the Up and Down buttons 3 0 Exporting amp Importing Data File Formats The creation and configuration of data file formats can be managed outside of Cell Assistant using popular tools such as Microsoft Excel Using the Export feature a selected data file format can be exported to a comma separated variable csv file for off line storage editing and or importing into another TestSystem Importing standard data file formats is an extremely quick and efficient way to set up a new TestSystem 8 2 Exporting amp Importing Data File Formats DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 8 Data Files A single data file format can be exported as follows 1 Select a Defined Data File format Click the Export button An Export a Data File Format pop up dialog appears Modify the default filename as needed e g change NNN to a valid number and click the Save button 4 Repeatthe previous steps to export other data file formats Previously exported data file formats can be re imported by clicking the Import button A warning dialog appears explaining the dangers of importing data file formats fr
29. annot edit any DSBasic scripts add or modify data channels change report formats etc Calibration This level requires a password The initial default password is cal This level is similar to the User level but adds access to all calibration features The operator can run TestPlans but with the additional capability to calibration data channels as often as needed Configuration This is the highest access level The initial default password is cfg This level provides access to all features of Cell Assistant and is mainly intended for used by TestSystem developers To change the operator access level select File then Password from the main menu or click the corresponding toolbar icon The Password dialog then appears allowing the operator to enter passwords to obtain a higher access level logout to lower your access level and to change the password values 13 4 Passwords DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 13 Miscellaneous 4 0 Status Bar A status bar is located at the bottom of the main Cell Assistant window An example is shown below For Help press F1 PLAN RUN DAQ LIM LOGGING USER 2 18 PM TestPlan Status Data Acquisition Status Limit Task Status Data Logging Status User Logon State Current Time Indicator Description Test Plan Status This indicator displays PLAN RUN whenever a TestPlan is r
30. ant and then adjusting all of the various control properties in order to obtain the desired size and appearance of the control By default many of the appearance properties of each control are initially determined by the channel they are connected to For example captions units numerical precision of readouts and scale numbering On Off text etc are initially taken from the Cell Assistant defaults for the connected channel For each property however you can uncheck the Use channel default box and enter your own value When done close the project and specify reasonable names for all forms files project files solution files project folders etc 9 2 Creating a VIP DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 9 Virtual Instrument Panels Limit Information Scale Colors Many of the meters can also make use of limits configured in Cell Assistant The limits which are available for any control depend on the selected channel Only limits that are monitoring the selected channel can be used These limits affect how the meter scales are drawn Meter scales are always the color GREEN by default Up to four of the available limits can be selected Once selected each limit must be assigned a color of RED or YELLOW The control will then repaint part of the scale based on the assigned color and High and Low limit values of each selected limit An example is shown below In this example two
31. ate with the device Similarly any attempt by a running TestPlan to access the device e g via a device control channel will be blocked This allows the developer to continue developing a TestSystem without the many communication error dialogs what would otherwise occur if the device were not disabled A device is disabled by selecting the device in the Added Devices list and then un checking the Device is Enabled checkbox Click the Save button to make the change persist after the TestSystem is closed DyneSystems Cell Assistant Disabling a Device 4 7 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 4 Hardware Devices 4 8 Disabling a Device DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 5 Channels Channels are used to exchange data and commands with all attached devices Input channels generally are created to provide sampled readings for the data acquisition subsystem Output channels on the other hand are generally used to issue commands to connected devices All of these channels are created and configured on the Channels page The Channels page is shown below L restSystem EmissionsCell_FTP ca2012 TestPlan Channels Limits Calibration Data Files Hardware Devices Name Type Dese Device channel Unis aicExhaust_PR Al C2 Board 05 Module 01 aicOpenB5M2 Board 05 Module 02 aicCrankcase PR Board 05 Module 03 aicSpiracle Vac Board 05 M
32. ated they are compiled into a standard executable file format exe file and placed into the VIPs sub folder of the main Cell Assistant installation folder From that folder a running TestPlan can launch and close any VIP as needed All of the graphical display objects e g meters gages etc are provided in the form of an ActiveX control This control VIPCONTROLS ocx is automatically installed and registered during Cell Assistant product installation Note Visual basic programming and the general use of Microsoft Visual Basic in general is not discussed here Please familiarize yourself with this product via practice as well as reading all on line documentation NO ACTUAL PROGRAMMING IS REQUIRED It is only necessary to place controls on a form modify their visual appearance and connect them to a Cell Assistant virtual data channel This can all be done graphically CHAPTER 9 Virtual Instrument Panels 1 0 Microsoft Visual Studio Express 2012 or similar Microsoft Visual Studio Express 2012 should be installed on the Cell Assistant computer Follow the product installation instructions All default folder settings should be used this includes a default folder structure to store and manage all Visual Basic projects Before a VIP can be created the DyneSystem s VIP Controls must be added to the Toolbox palette Perform the following additional steps when creating your first VIP form Display the Toolbox palette if not a
33. bes the syntax for these object methods They are also described in the on line help files 5 1 Open A data file is initially created or appended to using the Open method Multiple data files can be opened at any time as long as each uses a different configured data file format In other words for any single data file format only a single data file can be open and active at any time The syntax of the Open method is shown below FormatName Open Filename Mode NoHeaderFlag FormatName is the name of the configured data file format Filename quotes required is the actual name of the file being created Note that Filename is a string and must NOT contain a path or extension The file extension csv or txt will be added based on the configured File Format type while the data file will be logged to the DataFiles subfolder Mode determines whether the file will be added i e appended to or overwritten If added to data will be added to the end of the file The allowed Mode values are Add or Overwrite Mode is an optional parameter If omitted the default mode will be to add to the file The following are all valid uses of the Open method Formatl Open MyDataFile Add Formatl Open MyDataFile Overwrite Formatl Open MyDataFile defaults to Add mode Formatl Open MyDataFile Add NH When the Open method is executed Cell Assistant automatically writes three lines of header data identified b
34. bject only exists during the context of an executing limit handler The limit task creates this object and sets it to reference the current limit prior to running the limit handler This object allows methods of the currently active limit to be referenced in the limit handler without specifically referencing any particular limit The following methods are available ThisLimit Enable ThisLimit Disable ThisLimit High ThisLimit Low ThisLimit IsTripped ThisLimit Status DyneSystems Cell Assistant ThisLimit Object 7 9 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 7 Limits 7 10 ThisLimit Object DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 8 Data Files Recording data is an important function of any data acquisition system A running TestPlan may open and log data to multiple files simultaneously This allows low speed and high speed data to be logged at different rates and be stored in different file for post analysis Asynchronous entries such as limit exceptions random data snapshots error messages etc can also be inserted into any data file at any time The Data Files page is used to create data file formats A file format consists of an ordered list of channels to be logged the file format used to store the data and a default logging rate which can be changed at any time by a running TestPlan The Data Files tabbed page is shown below L TestSystem 40CFRPart86_Transientles
35. bugging output channels Later on after various analog digital or device control output channels have been created the Channel Viewer can be used to write data to these channels which ultimately send voltage commands speed torque setpoints etc to connected devices DyneSystems Cell Assistant Creating a TestSystem 3 3 DPD 008 02 e Copyright DyneSystems Inc CHAPTER3 Getting Started Close the Channel Viewer utility Select Control then Stop Data Acquisition from the main menu to stop data acquisition 2 3 TestPlan Tab On the TestPlan page create an empty Top Level TestPlan by clicking the Add button entering a descriptive name for the TestPlan and then clicking Done The DSBasic code for the empty TestPlan will appear in the TestPlan editor debugger The DSBasic code consists of a simple message box that when run pops up and waits for an operator to dismiss it Click the Save button and close the editor debugger window Run this new Top Level TestPlan by selecting it in the list and then clicking the Run button When a TestPlan is run Cell Assistant first starts the data acquisition subsystem as tested in the previous step Next the selected DSBasic TestPlan code is compiled and executed For this empty TestPlan click the OK button on the pop up message box to dismiss the message and ultimately end execution of the TestPlan The data acquisition subsystem is automatically stopped a
36. cal Channel Name Physical Device Name Name of Virtual channel used during calibration Name of TestSystem that performed the calibration Date Time stamp Method of calibration Actual Low Point un calibrated reading of channel T o mimiocgi oj u Desired Low Point desired reading of channel l Actual High Point un calibrated reading of channel J Desired High Point desired reading of channel K Gain Correction Factor L Offset Correction Factor M Comments DyneSystems Cell Assistant Exporting amp Importing Calibration Database 11 5 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 11 Calibration 11 6 Exporting amp Importing Calibration Database DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc 1 0 2 0 3 0 CHAPTER 12 Preferences Several aspects Cell Assistant can be configured by a TestSystem developer These application settings and or features are grouped into several tabbed preferences pages Each preference tab is discussed below The application preferences are accessed by selecting File then Preferences from the main system menu Appearance These settings only affect the appearance of the application Each should be obvious and are not discussed here Features The Network VIP Data Server can be enabled and configured here See previous section on Network VIP s for more information When enab
37. ce name prefix to a channel name allows identical channels e g a speed reading from similar devices to be differentiated in the TestSystem Finally the greatest time saver during channel creation is to automatically use the physical device name along with any other automatically generated prefixes as the virtual channel name This feature works well with devices that provide highly unique and well defined channel names e g a dynamometer controller provides speed torque and power reading channels or an emissions bench provides CO NOx and HC reading channels This feature does NOT work well with DAQ devices where the physical channel names are generic e g slot 1 voltage slot 2 temperature etc For these devices the TestSystem developer must generally manually enter a more meaningful name for each virtual channel Note The Add Channel page is designed to reduce the amount of time required for initial channel creation Additional configuration of each created channel if any is done after all channels have been created by returning to the main Channels tabbed page and then using the various channel modify features 6 0 System Function Channels Unlike most of the other channel types system function channels are configured immediately after they are created When the Add button is clicked the following dialog appears Channel Modify sysfunc J607 Correction Factor Dew Point J1349 Correction Factor Dew Point J13
38. ct with a user via a popup dialog is explained elsewhere in this manual 6 0 Flight Recorder Files The only unique TestPlan property at this time is the Flight Recorder configuration The Flight Recorder is a background task in Cell Assistant that automatically logs test data e g all channel data limit trips etc to a circular data buffer while a TestPlan is running This data buffer is referred to as a Flight Recorder It is mainly used to analyze TestPlans that have shutdown and or terminated prematurely due to errors When a TestPlan stops for any reason the Flight Recorder will contain a history of all channel data values and other events that occurred for a specified time interval prior to the stopping of the TestPlan All data in the circular buffer is written to an external file which can be viewed with a standard spreadsheet program The Flight Recorder Log Rate and Duration property requires a tradeoff decision between the duration of the data history retained prior to a TestPlan stop versus the rate at which all channel data is saved The default value for all TestPlans is a 1 0Hz recording of all data for 10 minutes which should be adequate for nearly all TestPlans All Flight Recorder files are saved in the FlightRecorders subfolder of the main Cell Assistant installation folder typically C CA2012 FlightRecorders The Flight Recorder filenames are of the form FlightRecXX csv where XX ranges from 00 to 99
39. d by the installed device drivers There are many programming situations where a VIP and the associated TestPlan need to exchange data that is NOT provided by a physical device e g not a measured voltage or thermocouple reading For these situations a pseudo device driver called the Virtual Instrument Panel Interface driver is available This driver can be added to a TestSystem using the Hardware page just as any other hardware device driver is added This driver presents large arrays of generic pseudo channels that can be used to create non hardware virtual channels These non hardware virtual channels obviously are not connected to any device and are not updated by the data acquisition sub system therefore a running TestPlan and an associated VIP are free to read write exchange data using these channels as needed 7 0 VIP Relocator As explained in other sections of this chapter Virtual Instrument Panels are created by building Windows Forms applications using the latest version of Microsoft Visual Studio Express The resulting VIP is an executable file that must be copied to the Cell Assistant VIPs folder Visual Studio also creates two dynamic link libraries i e DLL s that must be copied along with the VIP executable Because this is a tedious and mistake prone process a special application was created to facilitate the coping of all files It is called the VIP Relocator This program should be executed every time any change i
40. e name for the TestPlan and then clicking the Done button The following code stub is automatically generated When compiled and run it does nothing but pop up a message box and wait for the user to click OK to dismiss the message box and end the test Dyne Systems Inc Cell Assistant TestPlan Created 12 12 2015 Sub Main 3 Insert code here and remove next line MsgBox Test Over 0 SampleTestPlan End Sub Every Top Level TestPlan must contain exactly one Main subroutine TestPlan execution begins at this point Clearly more subroutines must be created and saved into this TestPlan as your overall test is developed The DSBasic programming language is NOT documented here The language reference is available on line in Cell Assistant Also numerous textbooks are commercially available that describe the similar Visual Basic programming language These can be a tremendous help to a novice programmer This manual does contain descriptions of the various language extensions that have been added to DSBasic These extensions allow channel data limits data files etc to be accessed and controlled by a running DSBasic TestPlan 2 0 2 1 Other TestPlans Whenever a Top Level TestPlan is selected and run four other TestPlan components are additionally compiled and executed These other TestPlan components are contained in separate TestPlan files in order to better manage and organize all TestPlan code
41. ecifies the logging period in Sec between successive data samples in the currently open log file Valid Period values are 0 05 0 1 0 2 0 5 seconds or any value between 1 and 600 seconds The following examples are valid uses of the LogPeriod method Using Data File Formats in a TestPlan DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 8 Data Files 5 8 5 9 5 10 Formatl LogPeriod 0 1 Formatl LogPeriod 5 0 Formatl LogPeriod 60 0 IsLogging This method allows a TestPlan to check if a data file is currently logging data If so this method returns TRUE If not this method returns FALSE The syntax of the IsLogging method is shown below FormatName IsLogging The following is a valid usage of this method It is typically used in shutdown and error handling routines that perform cleanup after an error The TestPlan can check if a data file format object is currently logging data to a file and if so disable logging before closing the file If Formatl IsLogging Then Formatl StopLogging End If SnapShot This method writes a single snapshot of all configured channel values into the currently open data file It is typically called when synchronous data logging is currently not active The syntax of this method is shown below Formatl SnapShot ForceEntry This method allows any text string to be added to the currently open data file The syntax of this method is shown below
42. els 6 System Function Channels 8 TestPlan Calculation Channels 9 Average Channels EE 9 Modify Configure Channels 10 Delete Rename Channels 11 Accessing Channels in a TestPlan 12 TestPlans Top Level TestPlans 2 Other TeStPlans eco ur RR RR RI sde desde 2 GLOBAL Subroutines 2 CALCULATED FUNCHONS i oLoLeizteitereizieLkReigtenikei3bkwkei eis 3 LIMIT Handlers 3 Running a TestPlan 4 TestPlan Editor Debugger 4 Adding DT CN 5 Flight Recorder Files 5 Programming TOPOS cessive sb NEE bee he cee sees EE NEEN EES 6 Language Extensions 6 Object References en e e mm hehe ret EE SNE E 6 Limits Audinpa iil i ceseketeretcRRER ERE rer eet RETE RENE npin 2 Configuring EU IER 2 Trigger Type 2 Trigger Range 2 LIME PHONE coron oot NN er do de 3 LIMIE Ve 3 Exporting amp Importing Limits 4 Limit Handler Procedure
43. emplate as follows Begin Dialog TestInputDialogTemplate 178 160 Test Parameters TestInput OKButton 132 8 40 14 CancelButton 132 28 40 14 TextBox 20 16 36 12 EnterUserName End Dialog Note The first line contains an additional parameter the name of the dialog proc function Please see the on line documentation for the DIgProc function for information regarding the format calling parameters and implementation of this function This is an advanced programming topic and will not be further explained here DyneSystems Cell Assistant Interacting with a dialog DPD 008 02 e Copyright DyneSystems Inc 10 3 CHAPTER 10 DSBasic Dialog Editor 10 4 Interacting with a dialog DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc 1 0 CHAPTER 11 Calibration Calibration allows the TestSystem operator to reduce eliminate measurement errors in many analog input and analog output signals Calibration of analog signals is a required component of many standardized testing protocols e g SAE 40CFR ISO etc Cell Assistant provides several methods of calibration the selected method is usually based on the availability of calibrated reference sources and or is dictated by a mandated testing standard The Calibration tabbed page manages the calibration of all calibratable signals This page is used to review the previous calibration results of each signal as well as to backup and restore the cal
44. ently run with the watchdog bypassed This will result in inadequate protection of the equipment A preferred method is to implement an interlocking contact on the bypass switch closed when the bypass switch contact is open and open when the bypass switch contact is closed This interlocking contact should be wired between the RTS and CTS lines of the serial port Cell Assistant will not allow the system to run a test if the contact from the RTS line to the CTS line of the serial port is open which indicated that the watchdog is bypassed If there is no watchdog timer module installed the Serial Port setting should be set to Disabled DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 13 Miscellaneous 1 0 Data Folder Structure Assuming Cell Assistant was installed using the default installation folder i e C CA2012 the following folder structure is created by the installer on the C drive of the host computer These sub folders are created in order to organize all data that is part of a TestSystem Some data is a static component of the overall TestSystem implementation e g configuration files Other data e g test data is generated on the fly by running TestPlans e g data logging files C3 Calibrations 3 DataFiles C3 DeviceSettings C Exports C3 FlightRecorders C2 IniFiles C2 SpreadSheets O TestSequences O TestSystems amp O TransientTesting CO VIPs 13 2 CHAPT
45. es are known For example they are available on a calibration sheet provided with a particular transducer In this case the GAIN and OFFSET correction values are simply entered into the calibration database No actual calibration procedure is performed 3 0 Calibration Procedure Any channel can be calibrated or re calibrated by selecting the channel on the Calibration tabbed page and then clicking the Calibrate button The following calibration page is then displayed 11 2 Calibration Procedure DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 11 Calibration Calibrate Input Channel aicThermocouple 001 Method Correction Factors C 1 Point Gain Correction Offset Correction o mi A Gain Correction A Offset Correction Z UNDEFINED Cancel Calibrate Data Acquisition Reading Desired High Point Start eer Low Point Start ScCep Comments First select the calibration Method to be used If Manual calibration is selected the Gain Correction and Offset Correction fields will be enabled allowing the calibration operator to simply enter the desired values If 1 Point calibration is selected a reference source e g a calibrated temperature pressure or voltage should be applied to the respective transducer Click the Low Point Start button to start the data acquisition subsystem The un calibrated reading of the c
46. esholds are set to values that will protect the Device Under Test DUT and or other equipment in the test cell Unfortunately the initial set of limit thresholds may not be appropriate for every DUT to be tested To accommodate the frequent need to adjust the limit thresholds a Limit Sets feature has been implemented Multiple sets of limit thresholds for analog input channels can be created The appropriate set of thresholds should be selected at the very beginning of the TestPlan Limit sets are created by clicking the Limit Sets button on the Limits page The Limit Set Editor will then be launched as shown below L Limit Set Editor Selected Limit Set 4 Move Left Move Right gt Default New_Set_2 KRY abc 120 124 124 220 200 Ey 20 300 300 cn 300 300 400 400 soc 00 400 800 800 800 400 450 600 800 800 800 900 800 C 900 00 900 123 123 123 456 456 456 Limit TC3 High 246 246 248 246 Low 135 me 13 15 j 135 The High and Low thresholds for all analog input channels are displayed The Default column lists the thresholds that were defined on the main Limits page Using this editor any column of thresholds i e a limit set can be selected duplicated and subsequently modified and saved Each set must be given a unique name as the name is used to set the desired Limit Set at the start of any TestPla
47. eter simply displays the value of the text channel 2 If connected to a digital channel the meter displays the ON text or OFF text depending on the current state of the digital channel 3 If the meter is connected to a limit the meter displays the configured tripped or not tripped text based on the current tripped state of the connected limit Pilot Light The Pilot Light has three modes of operation depending on the configured Input Source 1 If connected to a digital channel the color of the lamp is determined by the state of the digital channel 2 If connected to a device channel the color of the map is determined by whether or not the value of the device channel exactly matches the configured Match value 3 If the lamp is connected to a limit the color of the lamp is determined by the trip state of the connected limit VIPCONTROLS ocx DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 9 Virtual Instrument Panels Control Icon Description Push Button cil The Push Button control is simultaneously an input and output device When clicked data is written to the connected output channel On the other hand at all times the appearance of the button is determined by the state of the connected input channel Using a separate input channel in this way allows the creation of closed loop button operations If this feature is not needed a checkbox exists al
48. g Topics 6 7 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 6 TestPlans Programming Topics DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 7 Limits Limits are used to provide safety mechanisms in any TestSystem Limits are used to detect when physical channel values are too high too low out of range etc When a limit condition is detected the limit is referred to as being tripped When a limit trips dedicated DSBasic limit handling functions can be executed to handle the limit as needed e g take corrective action shutdown the test etc The Limits page is shown below M TestSystem 40CFRPart86_Transientlesting ca201 2 TestPlan Channels Limits Calibration Data Files Hardware Devices Defined Limits Procedure CellFaults CommErrorC2 CommE rrorlL5 CommErorPLC InterLocE sto MexaCalRange2 WatchdogE ror Limit Sets r Configuration r Trigger Settings High Limit fis Low Limit o Limit Name Monitored Channel CHAPTER 7 Limits 1 0 Adding a Limit Click the Add button to create a new limit Enter a unique name for the new limit select the channel to be monitored and then click the Done button to save the new limit The next section describes how to fully configure the new limit 2 0 Configuring a Limit Click the Modify button to configure a limit All limit configuration field
49. g was stopped The optional NoHeaderFlag parameter allows data logging to be stopped without adding the header line to the data file This allows the creation of numbers only data files that may be easier to analyze later on To prevent the logging of the header line set the NoHeaderFlag to NoHeader or NH If this parameter is omitted the default action is to always log the header line 5 6 LogRate This method changes the rate at which the synchronous data sample records are written to the currently open data file The syntax of the LogRate method is shown below Formatl LogRate Rate Rate specifies the logging rate in Samples sec i e Hz at which the data acquisition subsystem will add data entries to the currently open log file Valid Rate values are 0 005 0 01 0 02 0 05 0 1 0 2 0 5 1 0 2 0 5 0 10 0 and 20 0 Hz The following examples are valid uses of the LogRate method I o 02 5 0 Formatl LogRate Formatl LogRate 5 7 LogPeriod This method changes the rate at which the synchronous data sample records are written to the currently open data file Functionally this command is identical to the LogRate method except the data logging rate is specified as a period i e seconds between successive samples This method is generally more useful when specifying very slow sampling rates i e below 1 Hz The syntax of the LogPeriod method is shown below Formatl LogPeriod Period Period sp
50. ging 10 NH When the StartLogging method is executed Cell Assistant automatically writes a line of header data identified by HD in the first column This entry documents exactly when logging was started and at what rate Afterwards and at the specified logging rate Cell Assistant automatically writes lines of data which contain the values of the specified channels These data records are identified by TL in the first column The optional NoHeaderFlag parameter allows data logging to be started without adding the header line to the data file This allows the creation of numbers only data files that may be easier to DyneSystems Cell Assistant Using Data File Formats in a TestPlan DPD 008 02 e Copyright DyneSystems Inc CHAPTER 8 Data Files analyze later To prevent the logging of the header line set the NoHeaderFlag to NoHeader or NH If this parameter is omitted the default action is to always log the header line 5 5 StopLogging This method causes the data acquisition subsystem to stop logging data to the currently open file The syntax of the StopLogging method is shown below FormatName StopLogging NoHeaderFlag Valid uses of the StopLogging method are shown below Formatl StopLogging Formatl SopLogging NH When the StopLogging method is executed Cell Assistant automatically writes a line of header data identified by HD in the first column This data entry documents exactly when loggin
51. gital In H S Digital Out H A Device Status CH Textin IL5 a Analog In Ramped Reference Power Power Raw Power Integrated Speed Speed Raw Speed Integrated Torque Torque Raw Shaft Position Bet First Coast Down Interval Time Get Next Coast Down Interval Time Ramp Rate Up Ramp Rate Down Setpoint Sequence 1 Index Setpoint Sequence 2 Index Sine of Active Grade Angle nalog Out DIM c a t E L1 CDI 8g D CI D CDL D ad D DJ ad C1 CJ ad C s ERC B 2r 5 6 Creating Virtual Channels DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 5 Channels Virtual channels can quickly be added as follows 1 Selecta physical channel from one of the listed devices Or select one of the COMPUTED channel types from the top most folder of special i e non device channels Enter an appropriate virtual channel name see discussion below Click the Add button see discussion below regarding System Function and TestPlan Calculation channels 4 Repeatuntil all virtual channels have been created Virtual Channel Names Each virtual channel name must be unique in any TestSystem In addition since many virtual channels are referenced elsewhere in Cell Assistant e g in data file formats limits and DSBasic TestPlan code itis highly advisable to adhere to some type of channel naming convention This allows the type data direction and functi
52. hannel will be displayed When the reading is stable enter the known calibrated value of this reading The Accept button will become enabled The operator can now click the Accept button to accept the calibration at this value Or the STOP button can be pressed to stop data acquisition and perform no calibration at this time Note The Start button text changes to STOP when data acquisition is started If 2 Point calibration is selected the previous procedure must be performed two times once at a Low Point calibrated reference value and again at a High Point calibrated reference value Note For better calibration accuracy the calibrated reference points should be as far apart as possible with respect to the available span of the respective transducer DyneSystems Cell Assistant Calibration Procedure 11 3 DPD 008 02 e Copyright DyneSystems Inc 11 4 CHAPTER 11 Calibration 4 0 9 0 Calibration Database The calibration database is a single file containing the results of every calibration performed on this local computer The calibration database records the exact device and physical channel name of each calibrated channel thus if the same device channel is used in multiple TestSystems the channel need only be calibrated by one of the running TestSystems Afterwards the calibration is applied to every use of the channel by all other TestSystems The calibration database file is located in the Cal
53. hardware device presents a set of physical channels The name and type of each physical device channel is generally fixed however the TestSystem developer is free to create unique meaningful names for each virtual channel In addition each virtual channel can be separately scaled as needed if the scaling of the under laying physical channel does not match the requirements of the application The main feature of the Channels page is the large list of virtual channels The Name column lists the name of each virtual channel as specified by the TestSystem developer The Type column shows an abbreviated type code for each channel A list of type codes is shown below A detailed discussion of the various channel types is presented later in this document The Device and Device channel columns list the specific under laying physical channel from the specific device that each virtual channel is based on Type Code Channel Type Al Analog Input AO Analog Output DI Digital Input DO Digital Output TI Text Input TO Text Output DSI Device Status Input DCO Device Control Output AVERAGE Average CALC TestPlan Calculated SYS FUNC System Function TIMER Internal Timer 2 0 Sorting and Filtering the List Several mechanisms are available to help manage the displayed list of virtual channels These mechanisms are most useful for TestSystems with large channel counts First of all the list can be fil
54. ibration database Calibration Equation Each signal is calibrated by applying an OFFSET and a GAIN correction according to the following equation Calibrated Value GAIN correction Un calibrated Value OFFSET correction The Un calibrated value represents the raw channel reading from the connected hardware device The GAIN correction and OFFSET correction values are determined by the most recent calibration procedure performed on the respective channel Finally the Calibrated Value is the corrected value that is used throughout Cell Assistant when a TestSystem is executing CHAPTER 11 Calibration 2 0 Calibration Types Cell Assistant provides three calibration procedures 1 Point 2 Point and Manual The method used to calibrate any channel is often dictated by a mandated testing standard and or is restricted due to the availability of calibrated references sources 1 Point calibration requires exactly one calibrated reference source The channel reading can then be zeroed only at that reference value Since a second reference point is not used only the OFFSET correction can be computed 2 Point calibration requires two calibrated references sources allowing the channel reading to be zeroed at each reference value When a 2 Point calibration is performed both the OFFSET and GAIN correction values can be computed Finally Manual calibration requires no calibrated references sources The GAIN and or OFFSET correction valu
55. ibrations sub folder of the installation folder typically C CA2012 Calibrations CalibrationDatabase db The contents of this file should NOT be manually edited Corruption of the contents of this file may render the entire database useless The calibration database should be backed up as needed as explained in the next section Exporting amp Importing Calibration Database The entire calibration database can be backed up exported to a comma separated variable csv file for off line storage as follows 1 Click the Export button A Save Calibrations pop up dialog appears 2 Modifythe default filename only if needed e g change NNN to a valid number and click the Save button A previously exported calibration database can be re imported by clicking the Import button and selecting the calibration file to import Note When importing a saved calibration file new calibrations will be added merged to the existing calibration database as needed If a calibration entry already exists for a given channel the calibration data will be updated All other currently existing calibration entries remain as is No calibration entries will be deleted Exporting amp Importing Calibration Database DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 11 Calibration Each row of an exported calibration file contains the calibration data for one channel as listed below Column Data A Physi
56. ick the Export button An Export Limits pop up dialog appears 2 Modifythe default filename as needed e g change NNN to a valid number and click the Save button Previously exported limits can be re imported by clicking the Import button A warning dialog appears explaining the dangers of importing limit data from an external file If the imported file was previously exported from Cell Assistant and not externally modified in any way import errors are extremely unlikely Dismiss the warning dialog select the import file and click the Open button All limits specified in the file will be merged into the existing list of defined limits If errors occur during the import process it is extremely important to repair the file and re import else the TestSystem may be left in an unusable state Note When importing limits from a file limits will be added as needed and existing limits will be modified as needed All other currently existing limits remain as is No limits will be deleted 4 0 Limit Handler Procedure Each limit has a limit handler procedure written in DSBasic code that is called whenever a limit trips This handler can be very simple e g merely disable the limit and or or stop the running TestPlan or it can be complex e g attempt to determine the cause of the trip condition and try to rectify the cause When and how often the limit handler procedure is called was explained in a previous section
57. ist Note Itis generally NOT necessary to create a unique limit handler procedure for each defined limit in most TestSystems the same limit handler procedure can be used to handle many different limit conditions If so configure the selected limit by selecting one of the currently listed limit Procedures The selected limit procedure will now be shared by multiple limits Configuring a Limit CHAPTER 7 Limits If a new limit procedure is required enter the procedure name and click the Add button A default limit handler procedure will automatically be created and added to the end of the LIMITS TESTPLAN Note that all limit handler procedure names contain the prefix LIM_ This prefix is added automatically and does not need to be entered by the TestSystem programmer Adding DSBasic code to the actual limit handler procedure is described in a later section 3 0 Exporting amp Importing Limits The creation and configuration of limits can be managed outside of Cell Assistant using popular tools such as Microsoft Excel Using the limit Export feature the entire displayed list of defined limits can be exported to a comma separated variable csv file for off line storage editing and or importing into another TestSystem Importing standard sets of limits for frequently monitored data channels is an extremely quick and efficient way to set up a new TestSystem All currently defined limits are exported as follows 1 Cl
58. itored by the high priority limit task If not checked the selected limit will be monitored by the low priority limit task High priority limits and low priority limits are continuously evaluated when a TestPlan is executing If alow priority limit is triggered the limit procedure described below is executed When this happens high priority limits continue to be evaluated however if another low priority limit is triggered the corresponding procedure will not be executed until the currently executing low priority limit procedure has finished executing In other words the limit handlers for multiple tripped low priority limits are processed sequentially one low priority limit handler cannot interrupt another low priority limit handler On the other hand when a high priority limit is triggered execution of the low priority limit procedure WILL BE suspended and the high priority limit procedure will be executed Similarly if another high priority limit is triggered it will be ignored until the currently executing high priority limit procedure has finished executing high priority limit handlers are processed sequentially as well Limit Procedure When a limit is tripped Cell Assistant executes DSBasic code contained in a limit handler procedure All limit handler functions reside in a special TestPlan called the LIMITS TESTPLAN All currently available limit handler procedures in the LIMITS TESTPLAN will be shown in the Procedure l
59. iver must be developed Again contact Dyne Systems early in your development process in order to resolve driver availability issues The Hardware Device page is shown below L TestSystem 40CFRPart86_TransientTesting ca2012 TestPlan Channels Limits Calibration Data Files Hardware Devices Added Devices ce is Enabled r Driver Information Dune Systems Inc Companion Il Driver Data Acquisition System Copyright 2012 Dyne Systems Inc Version 2 00 r Device Information Device Name Instance of CHAPTER 4 Hardware Devices 1 0 Adding a Device A list of all currently Added Devices is listed on the left side of the page Click the Add button to add a new instance of a device to the TestSystem A list of available device drivers is listed on the right side of the page i e the Instance of list When a new driver instance is selected an abbreviated Device Name is automatically created These names must be unique among all installed devices Typically only a single instance of any device is added to a TestSystem thus the default name can be used If a second instance of the same device driver is being added modify the Device Name as needed to make it unique among all installed devices Click the Apply button when done The device configuration dialog will immediately be displayed And because device communication has not yet been configured an error dialog wil
60. l most likely appear Click OK to dismiss this dialog Device configuration is discussed below 2 0 Deleting a Device Click the Delete button to remove any previously added device from the system Note that deleting a device should rarely be necessary and should be done with extreme caution At most deleting a device allows you to remove the device and then re add the device using a new Device Name i e rename an installed device This should only be done at the very beginning of TestSystem development After channels limits data file formats etc have been created based on a device it is NOT advisable to delete a device unless absolutely necessary 3 0 Configuring a Device Each installed device must be properly configured by first selecting the device in the Added Devices list and then clicking the Configure button A set of tabbed dialogs will appear providing access to communications setup device configuration and simple device diagnostics The set of configuration dialogs are unique for each device They are not documented here as operator familiarity with each device is assumed A few sample dialogs are explained below 4 2 Configuring a Device DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 4 Hardware Devices 3 1 Serial Port Configuration Many devices connect to the host computer via a standard serial port e g COM5 COM6 etc Default values for the Baud Ra
61. ld return a value of 255 and let the limit task stop the TestPlan If a TestPlan is stopped by executing the End statement within the context of a limit handler or TestPlan calculated function also the results are unpredictable 5 0 Controlling Limits in a TestPlan When a TestPlan is compiled and executed the DSBasic compiler instantiates a limit object for each defined limit Using various methods defined for the limit object a TestPlan can enable disable limits change the high and low trip values and monitor the trip status of any limit The syntax of these methods is listed below DyneSystems Cell Assistant Controlling Limits in a TestPlan 7 5 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 7 Limits Method Description Data Type Example Enable Enable the limit Note the initial enable disable state of a limit when a TestPlan is initially started is configurable from the Limits tabbed page N A VoltageLimit Enable Disable Disable the limit It will no longer be evaluated by the limit tasks This is often used inside the limit handler to prevent additional trips until the limit condition is corrected and or cleared N A VoltageLimit Disable Low Read or set the value of the Low Limit trip point A running TestPlan can modify the Low Limit trip point using this method however each time the TestPlan is started the Low Limit trip point is always reset to the configu
62. led Cell Assistant will launch a background task that provides real time channel data to VIP s running on other computers via a network Network VIP s are rarely used so the data server is typically disabled Watchdog The watchdog feature in Cell Assistant provides a method of shutting the system down in the event of a computer failure hardware or software To accomplish this many systems include a small external watchdog timer module which is connected to a serial port When 12 2 CHAPTER 12 Preferences Watchdog Cell Assistant is running properly the DTR bit on the configured serial port is toggled approximately once each second Each time the watchdog timer module senses the DTR bit transition from low to high it resets its internal timer If this internal timer is not reset approximately every two seconds the timer will expire and cause the output contacts of the module to open These contacts should be wired up to the system such that the system shuts down when the contacts are open If the watchdog circuit is properly installed the system cannot be run unless the computer is on and Cell Assistant is running however in many cases it is still necessary to run without the computer on or without Cell Assistant running This could be accomplished by using a switch to short the output contacts of the watchdog module effectively bypassing the watchdog circuit If this is done however there is a danger that a test can be inadvert
63. limits that were monitoring on the selected channel were also selected to be used for this control both were High limits that overlap The first High limit has a trip point of 180 with the color RED assigned The other High limit has a trip point of 120 with the color YELLOW assigned To this point the only advantage of selecting limits is to provide an operator with visual feedback about limit information for a channel by painting limit ranges on the meter scale The real power of using limits with a meter is explained in the next section which describes how the meter border color changes when one of the selected limits trips in Cell Assistant Limit Information Border Colors The border color of a meter is always colored GREEN just like the meter scale however if limits are selected the border color can be used as a highly visual indicator of limit trip conditions If one of the selected limits trips the border will change to the same color that has been assigned to that particular limit The border will stay that color until the limit un trips i e the trip condition is cleared and reset Note that the border color has NOTHING to do with where the needle is pointing For example the needle could be pointing in the RED range yet Cell Assistant might not have that particular limit DyneSystems Cell Assistant Creating a VIP 9 3 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 9 Virtual Instrument Panels currently enabled
64. lowing the configured output channel to be used as the input channel as well The connected output channel can be a digital or device channel When connected to a device channel the configured Output value will be written to the connected channel whenever the button is clicked When connected to a digital channel the output value written in response to a button click is configurable 1 A TRUE constant can be written to the channel for every button click 2 A FALSE constant can be written to the channel for every button click 3 The last written 0 1 value can be toggled and written to the output channel 4 The current 0 1 value of the connected input channel can be read toggled and then written to the output channel Note Always be aware this button will drive the state of the output channel just as a running TestPlan in Cell Assistant drives the state of the channel programmatically using DSBasic commands Thus if the output channel is an output channel for a hardware device clicking the button will most likely cause commands to be sent to an external device Strip Chart z The StripChart control allows up to 6 Analog channels to be continuously plotted in real time The Y axis scale information for only one channel is displayed at a time Click the Channel button to cycle through the Y axis information for the other channels The color of this information will match the color of the appropriate channel on the stripchart C
65. lready displayed Add a new TAB to the palette and rename this tab to DyneSystems Locate the menu item to add components to this new TAB Select COM Components Browse for the file VIPCONTROLS ocx usually located in the C WINDOWS SysWOW64 folder 6 Click the Open button 7 Allgraphical controls will now be added to the Toolbox palette a fF Q N All graphical controls contained in VIPCONTROLS ocx will now appear on the Toolbox palette and are available for adding to any new VIP 2 0 Creating a VIP Launch Microsoft Visual Studio Express 2012 or similar and create a new Windows Forms Application project A single blank form will be displayed If this is your first project follow the setup steps listed in the previous section in order to install all DyneSystem s VIP Controls on to the Toolbox palette It is much easier to create VIP s when data acquisition is currently running in Cell Assistant If data acquisition is running all graphical control objects can access TestSystem virtual channel and limit information in real time therefore before creating your VIP launch Cell Assistant load the TestSystem file that will use this VIP and start data acquisition Now add various VIP controls to the form as needed All controls are discussed briefly in the next section Building a VIP is a simple process of adding various controls to a form connecting them to a virtual channel in Cell Assist
66. more information regarding the structure of limit handing functions A simple limit handler code stub is automatically created when a limit is created The DSBasic code in a limit handler can be as simple or as detailed as needed in order to handler the limit trip condition Note TheLIMITS TESTPLAN should NOT contain any other DSBasic code other than limit handler code DyneSystems Cell Assistant Other TestPlans 6 3 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 6 TestPlans 3 0 Running a TestPlan This section describes at a basic level the sequence of internal events that occur whenever a Top Level TestPlan is selected and run Understanding these steps can often be useful when debugging a TestPlan Step 1 Description All TestPlan components the selected Top Level TestPlan as well as the GLOBAL CALCULATED Functions and LIMIT Handler TestPlans are compiled These components must compile with no errors NOTE They are not run until a later step All language extensions are instantiated and registered This includes an object for each virtual channel each defined limit each Data File Format etc Once registered these objects can be referenced by all DSBasic TestPlan code The overall TestSystem is validated For example a DSBasic function must exist for each configured TestPlan calculated channel Similarly a DSBasic limit handler procedure must exist for each configured limit Data Acquisition i
67. n DyneSystems Cell Assistant Limit Sets 7 1 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 7 Limits The DSBasic compiler creates a unique DSBasic object for controlling the use of Limit Sets The object name is LimitSet The various methods associated with object are listed below Note Theuse of Limits Sets is an advanced programming topic This feature is typically programmed by DyneSystems ActiveSet This method allows a TestPlan to query the name of the active Limit set or change to a new active Limit Set Several uses of the ActiveSet method are shown below activeSet LimitSet ActiveSet Get name of currently active limit set LimitSet ActiveSet NameOfNewLimitSet Change to a new active limit set LimitSet ActiveSet Default Restore use of the Default limit set LimitSet ActiveSet Restore use of the Default limit set Note When any TestPlan is initially started the currently active Limit Set is always the Default set Count This method allows a TestPlan to determine the number of configured Limits Sets It is used along with the GetNames method to construct a list of available Limit Sets for display to an operator The syntax of the Count method is shown below NumSets LimitSet Count GetNames This method allows a TestPlan to retrieve the names of all available Limit Sets The syntax of the GetNames method is shown below Dim LimitSetNames As String LimitSet GetNames
68. n if needed DyneSystems Cell Assistant Average Channels 5 9 DPD 008 02 e Copyright DyneSystems Inc 5 10 CHAPTER 5 Channels 9 0 Modify Configure Channels Additional channel configuration is available for most channel types For example additional scaling y Mx B and logic inversion can be applied Also incorrect device and physical channel selections can be corrected As an example channel configuration dialogs for analog input and digital input channels are shown below Channel configuration modification is available by selecting the appropriate channel on the Channels tabbed page and then clicking the Modify button Note Double clicking the virtual channel name will also display the ChannelModify dialog Many of the configuration settings are cosmetic e g Engineering Units ON Text OFF Text etc They are typically of no use to a running DSBasic TestPlan They do appear on other dialogs for diagnostics and can also be optionally displayed on Virtual Instrument Panels Set these values only if necessary Channel Modify aicD1 Speed r Source Device CE Channel m D1 Speed Raw Cancel Sample Rate 25 Samples sec Scaling r Format Slope M IE Engineering Units RPM Dffset B o Decimal Places o D Disable Scaling Modify Configure Channels DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 5 Channels
69. nnels or 2 internal computed channels Physical device based channels are based on the physical device channels provided by the various devices via their associated device driver Internal channels are created by Cell Assistant e g timers and internal clocks Computed channels are computed from other DyneSystems Cell Assistant Channel Types 5 3 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 5 Channels channels using scripted mathematical equations and or one of several pre defined system functions Computed functions and system functions are explained in greater detail later in this document The Cell Assistant data acquisition subsystem continuously reads all input channel values in a synchronized fashion based on the configured sampling rate of each device It also continuously updates all internal and computed channels Because physical device channels are often used as inputs to other computed channels computed channels are always updated AFTER each data acquisition sample has completed This maintains the synchronization of physical channels with the computed channels Device channels Channel Type Representation Typical Use Analog Input Double precision floating point Typically represent readings from a data acquisition device e g voltage and temperature readings or speed and torque readings from a dynamometer controller Analog Output Double precision floating point Set output volt
70. o license file exists the following dialog will appear whenever Cell Assistant is started Cell Assistant No Cell Assistant License File has been found Contact DyneSystems with the following ID CO65 D131 4 License File will be created and sent to you You may continue to evaluate Cell Assistant however your TestSystem will be limited to 1 TestPlan 2 Hardware Devices 10 Channels 2 Limits 1 Data File 1 Hz As stated in the dialog contact Dyne Systems service department and provide the listed ID unique for each host computer If you have purchased Cell Assistant the ID will be used to generate a unique license file which will be e mailed to you The file i e License txt must be placed in the Cell Assistant installation data folder typically C CA2012 If you have not purchased Cell Assistant you may continue to use the product in Evaluation mode as described below 5 0 Evaluating Cell Assistant In evaluation mode Cell Assistant operation is restricted as listed below however these restrictions will not prevent you from fully evaluating the power and versatility of Cell Assistant 1 TestPlan 2 Hardware Devices 10 Channels 2 Limits 1 Data File Format 1 Hz logging rate DyneSystems Cell Assistant Evaluating Cell Assistant 2 3 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 2 Installation 2 4 Evaluating Cell Assistant DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc
71. odule 04 aicOpenB5M5 Board 05 Module 05 aicSCR_NOx_In Board 05 Module 07 aicNOx_Sensor Board 05 Module 08 aicOpenB5M9 Board 05 Module 09 aicOpenB5M10 Board 05 Module 10 aicBlowByFlow Board 05 Module 11 aiclntakeAirT emp Board 05 Module 12 aiclLS4CDynoPower IL5 D1 Power Display Filter aiclL54CDynoSpeed IL5 D1 Speed aiclL5A4CDynoT orque IL5 D1 Torque l Ze All aiclL5Throttlevacuum IL5 T3 Map Vac C Selected aiclL5T hrottlePosition IL5 T3 Position aicCOLo MEXA 7000 Channel 1 Data F Input aicCOHi MEXA 7000 Channel 2 Data f Output aicCO2 MEXA 7000 Channel 3 Data SEN aic02 MEXA 7000 Channel 4 Data aicTHC MEXA 7000 Channel 5 Data aicNOx MEXA 7000 Channel 6 Data aicMexaChannel MEXA 7000 Channel Data aicMexaChannel8 MEXA 7000 Channel 8 Data aicMexaSpanGasConcR angel MEXA 7000 Span Gas Concentration aicMexaSpanGasConcR ange2 MEXA 7000 Span Gas Concentration aicMexaS panGasConcRange3 MEXA 7000 Span Gas Concentration aicMexaSpanGasConcRange4 MEXA 7000 Span Gas Concentration aicMexaSpanGasConcR anges MEXA 7000 Span Gas Concentration aicSystemClock SYSTEM System Clock Count DEER TE 259 channels are listed CHAPTER 5 Channels 1 0 Virtual vs Physical Channels The Channels page manages all created virtual channels A virtual channel is any channel created by the TestSystem developer Each virtual channel is based on i e bound to one physical device channel Each installed
72. og statement e Dialog function e DigProc function 1 0 Creating a dialog The Dialog Editor creates a dialog template that fully describes the appearance and functionality of the created dialog So before launching the dialog editor click the cursor in the TestPlan editor to mark the location where the Dialog Editor will place the dialog CHAPTER 10 DSBasic Dialog Editor template when done From the main menu select TestPlan then Dialog Editor to launch the Dialog Editor Proceed to build the user interface dialog as needed When complete select File then Exit and Return in the Dialog Editor A dialog template that fully describes the created dialog will be placed in the currently open TestPlan A sample template containing two buttons and a text box is shown below Begin Dialog TestInputDialogTemplate 178 160 Test Parameters OKButton 132 8 40 14 CancelButton 132 28 40 14 TextBox 20 16 36 12 EnterUserName End Dialog Note Thistemplate can be modified updated by fully selecting the entire template i e select all text from the Begin Dialog to the End Dialog statements inclusive and then re launching the Dialog Editor 2 0 Launching a dialog Launching the dialog is a two step process 1 create an instance of the dialog template and then 2 launch the newly created instance This is accomplished using the following lines of DSBasic code Dim InputDialog As TestInputDialogTemplate
73. og can be used to exercise all configured PLC 1 0 bits and subsequently verify external PLC wiring safeties etc prior to actually using the channels in Cell Assistant Every installed device should initially be tested in this manner prior to creating virtual channels and using them in Cell Assistant Device Setup OCS351 Diagnose Settings Port Inputs EE a 45 58 38 T1000 0000000000 T1010 0000000000 9 T1020 0000000000 amp T1030 0000000000 amp T1040 0000000000 T1050 0000000000 SampleEnable Output Coils Dutput Registers x0 9 1 ease Geisel 4 6 Configuring a Device DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 4 Hardware Devices 4 0 Disabling a Device By default when a device is added to a TestSystem the device is fully enabled i e the data acquisition subsystem will attempt to acquire data from the device whenever data acquisition is started and or a TestPlan is run There are several scenarios where a device must be disabled e Adeviceis not yet available when TestSystem development as started e The device is temporarily unavailable due to repair and or maintenance e The TestSystem is being created off site where one or more devices are not available Regardless of the reason it occasionally becomes necessary to temporarily disable a device When a device is disabled the data acquisition subsystem will not communic
74. om an external file If the imported file was previously exported from Cell Assistant and not externally modified in any way import errors are extremely unlikely Dismiss the warning dialog select the import file and click the Open button The new data file format specified in the imported file will be added to the TestSystem and should appear in the list of Defined Data File formats If errors occur during the import process it is extremely important to repair the file and re import else the TestSystem may be left in an unusable state 4 0 Data File Contents A data file contains many types of records i e rows of data Clearly the majority of the records are the synchronously logged channel data however other types of data records such as file header information limit exceptions etc may also be recorded The first column of each data row contains a data record type field indicating the type and hence the format of each data record This field is necessary for correct parsing of the data file contents The following table lists the various type codes that may exist in the first column of each data row Type Code Description HD Header line Various header lines are automatically added as data files are opened and closed logging is started and stopped log rates are changed etc Other header lines provide column headers listing the channel names and channel units of each data column If needed header lines can be su
75. om torque and speed HP Sx T 5252 Input Description T Torque lb ft S Speed RPM Multiplication 2 channels This function multiplies any two channels together creating a product that is a new channel PRODUCT CH1 x CH2 Input Description CH1 Channel 1 CH2 Channel 2 DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc APPENDIX 1 DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc
76. omputer A The ComputerSelect control is used to create a VIP that runs over a network Select The absence presence of this control determines whether this particular VIP tries to access data on the local computer or on a remote computer on the network Network VIP s are explained below 4 0 Network VIP s By default all VIP s make a real time connection to Cell Assistant running on the same computer This is done internally via shared system memory Building a VIP that runs on another computer is a very simple task of forcing the VIP to connect to Cell Assistant via a network connection This is done by adding the ComputerSelect control to any VIP The absence presence of this control determines whether this particular VIP tries to access data on the local computer or on a remote computer on a network In the absence of a ComputerSelect control all controls on a VIP attempt to connect to a Cell Assistant virtual channel that exists on the DyneSystems Cell Assistant Network VIP s 9 5 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 9 Virtual Instrument Panels local computer As soon as a ComputerSelect control is added to a Visual Basic form all controls rely on the ComputerSelect control for their data The ComputerSelect control has two properties The Computer name and the TCP IP Port of the remote computer that this control should try to connect to You can enter either the name of the computer or the IP address
77. on of any channel to be quickly determined based on its name The Add Channel page provides a mechanism to automatically generate all or part of each virtual channel name Checkboxes allow the TestSystem developer to enable disable various components of virtual channel name generation Enabling all of the mechanisms can greatly reduce the amount of time spent creating channels e Add channel type prefix e Add device name prefix e Use physical channel name Channel type prefixes should always be used The remaining features are optional If enabled the following channel name prefixes are automatically generated based on the type of the selected physical channel Channel Type Channel Name Prefix Analog Input aic Analog Output aoc Digital Input dic Digital Output doc Text Input tic Text Output toc Device Status Input dsi Device Control Output dco TestPlan Calculated cle System Function sysfunc Internal Timer tmr If selected a device name prefix will be added immediately after the channel type prefix The device name prefixes consist of the physical device name exactly as listed in the channel list tree This feature is rarely used It is typically necessary when multiple instances of a device are installed ina DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Creating Virtual Channels CHAPTER 5 Channels TestSystem For example adding the devi
78. ormation regarding the VIP Relocator tool 2 0 Backing Up Data Backing up your TestSystem is a trivial task simply archive all data in the installation folder e g C CA2012 as well as all sub folders All Cell Assistant product files are stored elsewhere and can easily be re installed using the product installer thus those files require no backup As explained previously the installation folder contains all generated data as well as all static configuration data and licensing files Backing up everything in this folder will facilitate a full restore of the system later if needed Note A few configuration data items are stored in the system registry e g passwords appearance settings etc It is not necessary to backup these items as they typically can be re established should Cell Assistant require a complete restore re installation DyneSystems Cell Assistant Backing Up Data DPD 008 02 e Copyright DyneSystems Inc 13 3 CHAPTER 13 Miscellaneous 3 0 Passwords Cell Assistant provides three levels of access to all features and data two of the levels are password protected Access Level Description User This is the most basic access level This is the default access level when Cell Assistant is initially started No password is required This level allows the user to run a test i e select and execute a TestPlan and to view various screens But no editing is allowed The operator c
79. ple is shown below Dim aocReferenceToAnyAnalogChannel As AnalogChannel Set aocReferenceToAnyAnalogChannel aocDynoSetpoint aocReferenceToAnyAnalogChannel 100 Programming Topics DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 6 TestPlans This example accomplishes the same thing at the previous example The first line creates i e Dim s the reference object The second line establishes the channel object that will be referenced Note that the reference object can only reference objects of similar type In this example aocDynoSetpoint must be an analog channel Finally in the third line the value of the reference object is set which actually sets the value of the aocDynoSetpoint channel Similarly any other method property of the original object can be invoked modified using the reference object This example really does not demonstrate the true usefulness of using object references Object references are most useful when the same set of operations needs to be performed on several objects It is easier to write a subroutine that performs these operations on an object reference Then the Set command can be used to set the reference object to the appropriate object prior to calling your subroutine that operates on the reference object Note Object references are more likely to be used with limit objects and data file format objects than channel objects DyneSystems Cell Assistant Programmin
80. ppressed resulting in a data only log file TL Timed logged data line This line is a synchronously logged snapshot of all channel data It was automatically recorded by the data acquisition subsystem SL Snapshot logged data line This line is an asynchronously logged snapshot of all channel data This snapshot was initiated using the SnapShot method in a running TestPlan Snapshot log entries are typically made as needed when normal synchronous logging by the data acquisition subsystem is disabled LM Limit Exception data If enabled as part of the data file format the limit processing subsystem will automatically add these entries whenever a limit trip condition occurs FE Forced Entry A running TestPlan can asynchronously log any text string into a data file at any time DyneSystems Cell Assistant Data File Contents 8 3 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 8 Data Files 5 0 Using Data File Formats in a TestPlan Logging data to a data file is completely controlled by a running TestPlan When a TestPlan is run the DSBasic compiler instantiates a unique DSBasic object for each configured data file format Using various object methods new data log files can be created and or existing data log files can be opened Data logging is started and eventually stopped Finally the data log file is closed causing all data to be permanently stored on the local hard disk drive This section descri
81. rFlag to NoHeader or NH If this parameter is omitted the default action is to always log the header line 5 3 IsOpen This method allows a TestPlan to check if a data file is currently open using the specified data file format If so this method returns TRUE If not this method returns FALSE The syntax of the IsOpen method is shown below FormatName IsOpen The following is a valid usage of this method It is typically used in shutdown and error handling routines that perform cleanup after an error The TestPlan can check if a data file is actually open and if so close it If Formatl IsOpen Then Formatl Close End If 5 4 StartLogging This method initiate s synchronous data logging to the currently open data file i e the Open method must have been previously called The syntax of the StartLogging method is shown below FormatName StartLogging Rate NoHeaderFlag Rate is an optional parameter If present it specifies the logging rate in Samples sec i e Hz at which the data acquisition subsystem will add data entries to the currently open log file If Rate is not specified the default logging rate specified in the data file format will be used Valid Rate values are 0 005 0 01 0 02 0 05 0 1 0 2 0 5 1 0 2 0 5 0 10 0 and 20 0 Hz The following examples are valid uses of the StartLogging method Formatl StartLogging Formatl StartLogging 0 01 Formatl StartLogging 10 Formatl StartLog
82. red value on the Limits page Double TripLevel VoltageLimit Low VoltageLimit Low 2 5 High Read or set the value of the High Limit trip point A running TestPlan can modify the High Limit trip point using this method however each time the TestPlan is started the High Limit trip point is always reset to the configured value on the Limits page Double TripLevel VoltageLimit High VoltageLimit High 8 5 Status Determines if trip conditions exist i e the value of the monitored channel is too low too high out of range etc This method is typically used when a limit has been disabled allowing the TestPlan to leisurely check if trip conditions have cleared before re enabling the limit Boolean If VoltageLimit Status Then Trip Conditions Exist Do something here End If IsTripped Returns the trip state of the limit This property is subtly different from the Status property The state of this property will persist until the limit task re evaluates the limit conditions even though the actual limit trip conditions may have changed Boolean If VoltageLimit Status Then Limit has tripped Do something here End If Controlling Limits in a TestPlan DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 7 Limits 6 0 Limit Sets When configuring the High and Low limit thresholds for analog input channels the thr
83. result Dialog InputDialog The first line of DSBasic code creates an instance of the dialog template and the second line of DSBasic code launches the instance Note that the Dialog statement does not return until the dialog is closed A result code is returned indicating the exact dialog button that was clicked to dismiss the dialog See the on line help for the Dialog function for more information regarding the returned result code 3 0 Interacting with a dialog Many dialogs interact with an operator in order to gather various types of user input validate parameters etc To build more powerful user dialogs a dialog proc function can be added to any dialog template This function is simply a DSBasic function with a pre defined format that interacts with a running dialog The DSBasic run time engine calls this function as needed in order to allow various events to be handled For example the DSBasic run time engine will call the dialog proc function when the dialog is initially displayed allowing your code to initialize all controls and data fields Similarly the function will be called whenever a button is clicked a list selection is changed a 10 2 Interacting with a dialog DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 10 DSBasic Dialog Editor checkbox is checked unchecked etc A dialog proc function can be added to the previous dialog template example by modifying the t
84. s it is also a good practice to build your design in smaller increments therefore initially create just a few analog input channels e g temperatures voltages speed readings torque readings etc for each installed device Start data acquisition to test the channels created in the previous step as well as to further test communication with the connected devices Select Control then Start Data Acquisition from the main menu A warning dialog may appear since the previously created channels have not yet been calibrated Check the Do Not Warn Again checkbox and click the Continue button to start data acquisition If all devices are properly connected and configured data acquisition will start with no errors The DACH indicator will appear in the status bar at the bottom of the Cell Assistant main application window If any error dialogs appear one or more devices are not properly connected and or configured Return to the Hardware Devices tab to resolve these issues Use the Channel Viewer utility to view and validate all acquired data Select View then Channel Data from the main menu The Channel Viewer utility will appear All channel data is displayed and actively updated Note The Channel Viewer utility can be used to modify channel data While this typically makes no sense for input channels as they are continuously re acquired and updated by the data acquisition subsystem this is extremely helpful for de
85. s a value in some memory location in the computer Setting the value of a channel object on the other hand does more than that Setting the value of a channel object that happens to be an output channel will cause a command to be sent to a device Similarly reading the value of a channel object actually returns a data value that was sampled from a device by the data acquisition subsystem This concept needs to be clearly understood When accessing Cell Assistant objects in a TestPlan you may actually be communicating with an external device 7 2 Object References There are two methods by which any object can be accessed by a running TestPlan The first method is discussed in the respective chapters on channels limits and data file formats This is the direct method where an object is accessed using its name For example every channel object has the same name as the channel it represents For example a channel named aocDynoSetpoint will be represented in the TestPlan by a channel object named aocDynoSetpoint You can then send a setpoint value to the Dynamometer controller in the TestPlan using the following line of DSBasic code aocDynoSetpoint 100 Cell Assistant objects can also be accessed via a reference to the object In DSBasic you can create an object that can be used to reference other objects of the same type The reference object is NOT an object itself It must reference another object in order to be used An exam
86. s are now enabled 2 1 Trigger Type Each limit is either an Edge Triggered limit or a Level Triggered limit The Trigger Type determines when and how often the DSBasic limit handler routine is executed when a limit trips For an Edge Triggered limit the DSBasic limit handler will only be called at the onset and offset of the trip conditions The limit handler will be called once when the trip condition is first detected It will NOT be called again until the trip condition clears itself Thus the DSBasic limit handler will be called exactly two times when an Edge Triggered limit event occurs The DSBasic limit handler can easily distinguish if it is being called at the onset or at the offset of a trip condition and thus execute a unique set of instructions for each condition This is explained in a later section For a Level Triggered limit the DSBasic limit handler will be repeatedly called as long as trip conditions persist for a given limit When the limit task determines that trip conditions exist for a limit the DSBasic limit handler is called If this handler fails to correct the cause of the trip and or doesn t disable the limit the limit task will evaluate all of the other limits and eventually will re evaluate the tripped limit and see that trip conditions still exist Thus the limit handler will be called again This series of events will continue indefinitely until the trip condition is cleared or the limit handler dis
87. s frequently used in an engine test cell environment e g HP to Watts conversion corrected horsepower calculations SAE and ISO corrections factors System functions are defined in an Appendix at the end of this document Internal Timer Integer Timer channels count up or down in 1 second increments They can be preset to start at any value and can be completely controlled by a running DSBasic TestPlan DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Channel Types CHAPTER 5 Channels 5 0 Creating Virtual Channels All virtual channels except average channels are created using the Add Channel dialog which is displayed by clicking the Add button on the Channels tabbed page This dialog presents an Explorer style list of all installed devices as well as all of the physical channels each device makes available for the creation of virtual channels By expanding the various folders under each installed device the TestSystem creator gets a full view of the channel capabilities of each device The Add Channel dialog is shown below Add Channel Virtual Channel Name CH COMPUTED CHANNELS Die hess LS System Function aicD1_RampedReterence ote TestPlan Calculation 9 Timer amp C2 Iw Add channel type prefix En Analog In Add device name prefix DE I Use physical channel name H A Device Status CH Text In 5 DL205 9 Analog In CH Di
88. s made to a VIP and the VIP executable is subsequently rebuilt DyneSystems Cell Assistant VIP Relocator 9 7 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 9 Virtual Instrument Panels During installation a desktop shortcut to the VIP Relocator program is installed as shown below Double click the icon to launch the program WLP das chis The following window will appear On the first launch of the application all fields will be blank Click the folder icon to browse for the path to the main Projects folder where all VIP projects reside under Once selected the relocator will then scan all subfolders for VIP project executables and copy them the Cell Assistant VIPs folder All copied files are displayed in the Results window VIP Relocator v 1 0 1 Select your Visual Studio Projects folder C Users DanC Documents Visual Studio 2012 Projects za Operation Results 10 5 2015 10 42 54 AM Copied the following files 1 C Users DanC Documents Visual Studio 2012 Projects Main VIP Main VIP bin Release MainVIP exe gt C CA2012 VIPs MainVIP exe VIP Relocator DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 9 Virtual Instrument Panels On subsequent launchings of the VIP Relocator the projects path has already been established In this case the following confirmation dialog is displayed Click the Yes button to copy all files P Would you like to copy from the la
89. s started The 20 Hz Master Timing loop and device sampling loops are started and synchronized 2 Second Delay This delay allows the data acquisition system to begin retrieving valid data samples prior to beginning execution of the TestPlan code monitoring limits recording data files etc The TestPlan Flight Recorder is started The Flight Recorder is explained below The Main routine in the selected Top Level TestPlan is started Your TestPlan is now officially running The High and Low priority limit threads are started Note The data acquisition system can be started by itself i e no TestPlan is selected and run by selecting Control then Start Data Acquisition from the main menu In this case only the first four steps listed above occur 4 0 TestPlan Editor Debugger All TestPlan creation is done with the DSBasic Editor Debugger It is fully documented in the Cell Assistant on line documentation TestPlan Editor Debugger DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 6 TestPlans 5 0 Adding Dialogs Most lines of DSBasic code are used to supervise control execute a test however DSBasic also provides a programming framework for creating simple dialogs Simple dialogs can be dynamically created and launched from within a TestPlan Simple instructions regarding the use of the DSBasic dialog editor as well has how to write DSBasic code to intera
90. s well 2 4 Limits Tab As your TestSystem grows in features and complexity the Limits page is used to add limits and limit procedure handlers to various configured channels Limits are fully described later in this document 2 5 Data Files Tab Most all TestSystems require the logging of data The Data Files page is used to create Data File formats A format consists of a set of channels to be logged as well as the logging rate and file storage format Just a few lines of DSBasic code are required to open a file and begin logging to a file using these defined formats Data Files are fully described later in this document 3 0 Calibration The calibration page is used to manage the calibration of analog input and analog output channels Calibration is fully described later in this document Calibration is perhaps the last Cell Assistant feature to become familiar with An entire TestSystem can be created debugged and finalized without the need of precise calibration of all analog channels 3 4 Calibration DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 3 Getting Started 4 0 Adding Virtual Instrument Panels VIP s Visually monitoring and or interacting with a test is an important component of nearly every TestPlan Cell Assistant provides a set of graphical controls in the form of an ActiveX control Using any version of Microsoft Visual Basic these controls can be added to any form to create custom
91. s where Data Files are not or cannot be used DyneSystems Cell Assistant Flight Recorder Files 6 5 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 6 TestPlans 7 0 Programming Topics 7 1 Language Extensions Other chapters in this manual describe how to configure channels limits data file formats etc These chapters also describe how to access and or reference channels limits data file formats etc in a running TestPlan which is implemented in the DSBasic programming language The ability to access these items in the DSBasic language is accomplished via language extensions DSBasic is an object oriented language You can programmatically create objects of various kinds and manipulate any objects properties and or invoke any of an object s methods Each time a TestPlan is run Cell Assistant automatically creates are large set of global objects that can be accessed by the TestPlan One channel object is created for every virtual channel that has been created and configured in the Channels page Similarly one limit object and one data file object is created for every limit and data file format that has been created and configured on the respective page These global objects act like any other object in the DSBasic language except these objects provide an interface between the running TestPlan and the underlying Cell Assistant data acquisition subsystem Setting an object to a value i e object value N typically just set
92. ssure kPa di Dew Point C t Intake Air Temperature C J1349 Correction Factor Dew Point This function calculates the SAE J1349 correction factor for torque and power using dew point as the measure of humidity Where Correction Factor 1 18 x 99 x du 0 18 B E 298 tap 17 2694 tp 238 3 E 0 61078 e Input Description B Barometric Pressure kPa t Dew Point C dp t Intake Air Temperature C APPENDIX 1 System Channels J1349 Correction Factor Relative Humidity This function calculates the SAE J1349 correction factor for torque and power using relative humidity as the measure of humidity Correction Factor 1 18 x 99 x MEUS 0 18 B E V 298 0 17 2694 ue po lt p 61078 ve ces 5 Input Description B Barometric Pressure kPa RH Relative Humidity 96 i Ambient Air Temperature C t Intake Air Temperature C ISO 3046 1 Correction Factor This function calculates the ISO 3046 1 correction factor for torque and power Where 1 2 0 6 Correction Factor 99 1 y t 273 b 298 P B RHTT L T T 7 2 T S T T 5 T 0 620854 T 0 0390123 T 0 00188944 T 0 00000663369 T 0 000000657956 Input Description B Barometric Pressure kPa RH Relative Humidity 96 t Intake Air Temperature C T Temp of Relative Humidity Sample
93. st known Projects folder C Users DanC Documents Visual Studio 2012 Projects CHIC DyneSystems Cell Assistant VIP Relocator DPD 008 02 e Copyright DyneSystems Inc CHAPTER 9 DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 10 DSBasic Dialog Editor While the previous chapter describes how to create rich looking Virtual Instrument Panels capable of displaying acquired data in real time the DSBasic framework provides another graphical user interface mechanism the Dialog Editor The Dialog Editor is a perfect choice for creating simple user interfaces that display relatively static data and or for gathering user input prior to a test Simple dialogs consisting of buttons lists text entry check boxes etc can be created These dialogs can if needed be used to display real time data however they are cosmetically limited and somewhat difficult to program It is best to create VIP executables for real time data A simple dialog created with the DSBasic Dialog editor requires three coding tasks These tasks are discussed briefly below 1 Define and create the dialog using the Dialog Editor Add a few lines of DSBasic code to a TestPlan to launch the dialog Create a DSBasic handler function to interact with the launched dialog Note Please consult the DSBasic on line reference manual for more information regarding the editor as well as the following DSBasic functions e Begin Dial
94. sure in Hg Inches of Mercury to kiloPascals This function converts a pressure in inches of mercury in Hg at 0 C to a pressure in kiloPascals kPa KPA INHGi 3 38638962 Input Description INHG Pressure in Hg LB FT to Newton Meters This function converts a torque in pound feet Ib ft to a torque in Newton meters Nm NM T 1 355817947 Input Description T Torque lb ft Newton Meters to LB FT This function converts a torque in Newton meters Nm to a torque in pound feet Ib ft LB FT T 0 73756215 Input Description T Torque Nm Horsepower to Kilowatts This function converts power in horsepower HP to power in kilowatts kW KW HP 0 7457 Input Description HP Power HP DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc APPENDIX 1 System Channels Kilowatts to Horsepower This function converts power in kilowatts KW to power in horsepower HP HP KW 0 7457 Input Description KW Power kW Brake Specific Fuel Consumption This function calculates Brake Specific Fuel Consumption BSFC from fuel consumption and power The units depend on the units used for power and fuel consumption BSFC F P Input Description F Fuel consumption Power Horsepower This function calculates horsepower HP fr
95. t cell changes only one TestSystem file is typically required Launch Cell Assistant by double clicking the desktop icon Create an empty TestSystem file as follows Select File then Password from the main menu Enter the default configuration password i e cfg and click OK Select File then New from the main menu An empty TestSystem appears Select File then Save As from the main menu a A ON Create a unique name for this TestSystem file and save it in the default TestSystems folder The main TestSystem dialog shown below consists of six tabbed pages TestPlan Channels Limits Calibration Data Files and Hardware Devices Each tabbed page manages a fundamental component of your TestSystem To create your first TestSystem visit the tabbed pages in the order described in this chapter Each page is also described in greater detail in chapters that follow The following list is merely a brief summary of the steps needed to create a TestSystem L TestSystem TestSystem1 TestPlan Channels Limits Calibration Data Files Hardware Devices r Top Level TestPlans TestPlan Properties Name On Flight Recorder Log Rate and Duration Ed Add Delete Edit Other TestPlans GLOBAL GLOBAL CALCULATED LIMIT Group 1 Group 2 Functions Handlers 3 2 Creating a TestSystem DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc
96. tPlan For example the value of a channel can be loaded into a variable using the following line of DSBasic code Variables aicIL5ACDynoSpeed Where aicIL5ACDynoSpeed is a virtual channel based on a speed channel from a dynamometer controller The value of the channel can now be used in other calculation in decision elements etc Virtual channels are the simplest language extension to DSBasic additional language extensions are explained in the TESTPLANS chapter Note To properly reference a virtual channel in a TestPlan it is extremely important to spell the virtual channel name correctly If not the DSBasic compiler will interpret the misspelled channel name as another variable resulting in an improperly executing TestPlan sequence To prevent this common error copy paste functionality has been added to the channel list To copy a virtual channel name into the global copy buffer select the channel name using the right mouse button and then select Copy Name from the pop up menu shown below Alternatively press CTRL C on the keyboard Modify Rename Delete Average this channel Copy Mame Paste the channel name into any DSBasic TestPlan in the usual manner i e CTRL V The data value of the correctly spelled virtual channel is now accessible in the TestPlan 5 12 Accessing Channels in a TestPlan DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 6 TestPlans While
97. ta file It can also be used to add channel unit information that may have been previously suppressed in the Open method with the NoHeader flag The syntax of the WriteChannelUnits method is shown below Formati WriteChannelUnits 5 13 WriteChannelHeader This method is equivalent to successively calling the WriteChannelNames and WriteChannelUnits methods except this method guarantees the channel names header record and the channel units header record are logged in consecutive rows in the data file The syntax of the WriteChannelHeader method is shown below Formatl WriteChannelHeader 8 8 Using Data File Formats in a TestPlan DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc CHAPTER 9 Virtual Instrument Panels Virtual Instrument Panels i e VIP s are on screen displays of real time data as it is acquired by Cell Assistant Each VIP consists of a large Windows form containing graphical display objects such as analog meters gages buttons pilot lights etc allowing a user to interact with a running TestPlan in Cell Assistant Each VIP should be designed to optimally display data for a specific TestPlan To improve readability and viewing of all live data multiple VIP s can be created and launched by a single TestPlan if needed VIP s are executable programs developed in Visual Basic using standard development tools such as Microsoft Visual Basic Express or Microsoft Visual Studio Once cre
98. te Parity Data Bits Stop Bits and Flow Control are initially provided by the device driver and do not need to be changed The only required new setting is the Connection value For each device select the serial port e g COM5 COM6 etc to which the device is connected Note Always verify the communication settings in the device as well They must match the settings in the device driver Also if possible always configure the device to use the highest available Baud Rate Note Changes to communication settings are activated when the configuration dialog is closed therefore close then re open the configuration dialogs whenever a communication setting is modified Device Setup OCS351 Diagnose Settings Pot Baud Rate Parity None C Odd C Even C Mark C Space Connection None DI m Data Bits Be E m Stop Bits QE Ko de DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc m Flow Control e None Xon Koff C RTS CTS C DTR CTS Configuring a Device CHAPTER 4 Hardware Devices 3 2 Network Configuration Some devices connect to the host computer via a standard ethernet connection If so the device driver will provide a network configuration page similar to the following Network devices are typically based on standard TCP IP sockets thus the IP address and listening socket port number of the attached device must be configured in the driver Consult
99. ted however note that the CALC FUNCTIONS TESTPLAN is immediately opened in the background when a TestPlan Calculation channel is created This occurs because Cell Assistant immediately generates a DSBasic code stub for the newly created calculated channel The stub initially just returns a value of 0 0 The DSBasic implementation for the calculated channel may be entered now or at any time later on during TestSystem development As is the initial code stub will compile with no errors allowing TestSystem development to proceed without the final implementation of the calculated channel Additional information regarding the implementation of TestPlan Calculation channels is presented in the TESTPLANS chapter of this document 8 0 Average Channels Average channels are NOT created from the Add Channels page Average channels are used to filter smooth other analog input channels Average channels are created from the Channels tabbed page Right click on any analog input i e Al channel and the following pop up menu will appear Modify Rename Delete Average this channel Copy Name Select Average this channel and the respective Channel Modify dialog will appear Configure the channel as needed and click OK A default virtual channel name is automatically created It consists of the name of the selected analog input channel preceded by an AVE_ prefix This default channel name can be renamed later o
100. tered using the checkboxes in the Display Filter group box The All check box is the default setting where all created virtual channels are always displayed Click the Selected checkbox to enable filtering The remaining checkboxes are then enabled as needed allowing the operator to filter the list based on channel type and direction Secondly the displayed list of virtual channels can be sorted alphabetically by column by clicking the Name Type or Device column header buttons respectively Sorting the listed channels by 5 2 Sorting and Filtering the List DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 5 Channels Type and Device are the most useful especially just prior to exporting the channel list to an external file 3 0 Exporting amp Importing Channels The creation and configuration of virtual channels can be managed outside of Cell Assistant using popular tools such as Microsoft Excel Using the channel Export feature the entire displayed channel list can be exported to a comma separated variable csv file for off line storage editing and or importing into another TestSystem Importing standard sets of channels for various devices is an extremely quick and efficient way to set up a new TestSystem All currently displayed channels are exported as follows 1 Select the appropriate Display Filter settings as only the currently displa
101. ting ca201 2 TestPlan Channels Limits Calibration Data Files Hardware Devices Defined Data File Formats p Channels Included Channels Available Channels aicD1 Power D aicD1 Torque aocD1_Setpoint aocT3 Setpoint aicCOLo aocD1 RamphRate aicD1 RampedReference aocT3 RampRate aicSystemlnlet Temp aicSystemOutT emp aicAfterCooler_DP Export aicBarometer aiclntakevac PR aiclMP aicCeilingE astT emp aicCeilingw estT emp aicCompOutT emp Properties 1 aicCoolantlnTemp d aicCoolantOutT emp aiclL5Throttle acuum n m aicEngineCoolantMix aicMexaChannel8 Name EngineMapDataFile aicEngineDilPressPS2 aicMexaSpanGasConcRangel 3 aicExhaust PR aicMexaS panGasConcRange2 File Format Comma Separated Var csv i 8 aicMexaS panGasConcRange3 aicDevice_PR aicMexaS panGasConcRange4 P aicDevice_DP Remave aicMexaSpanGasConcRHange5 LogRate 1Hz aicBlowbyTemp aicNO aicintakeAirT emp R OC aicNOx 1 Include Limit Exceptions aicLFE_DP Ste aic02 Done Cancel aicD1 Speed EL aicT3 Position amp dd Delete Delete JP TER uplicate Import CHAPTER 8 Data Files 1 0 Creating a Data File Format Click the Add button to create a new data file format Then set all of the properties of the data file format Note that the Name property is the name of the data file format NOT the name of the file where the data will ultimately be saved The actual file name will
102. uel meters etc The control subsystem consists of running TestPlans written in the DSBasic programming language DSBasic is a powerful scripting language similar to the Microsoft Visual Basic programming language But it also incorporates many language extensions specifically designed for data acquisition and control Using these language extensions a running DSBasic TestPlan can access channel data as well as control the operation of all connected devices DSBasic is an excellent programming language for writing TestPlans ranging from extremely small and simple tests e g basic dynamometer speed and torque control engine endurance tests etc to extremely large and complex tests e g EPA drive cycles 40CFR Part 1065 Emission Testing SAE Roadload and Coastdown tests etc Cell Assistant provides two methods for creating Graphical User Interfaces First the DSBasic development environment includes a dialog editor The dialog editor is an ideal tool to build simple dialogs for data entry at the start of a test Secondly Cell Assistant also includes an ActiveX Control that can be used to create high quality virtual instrument panels VIP s This control provides a rich set of user interface controls such as analog meters digital meters strip charts buttons and pilot lights Using Microsoft Visual Basic as a VIP builder these controls can be used to build high quality user interfaces for Cell Assistant Absolutely no programming is required
103. unning If a TestPlan has been terminated by a limit exception handler the indicator displays ABORTED It is blank at all other times Data Acquisition Status This indicator displays DAQ when data acquisition is running otherwise it is blank Limit Task Status This indicator displays LIM when the limit tasks are running i e whenever a TestPlan is running If a limit exception is detected it displays TRIP The indicator will again display LIM when all limits return to normal It is blank at all other times Data Logging Status This indicator displays LOG OPEN whenever a running TestPlan opens a data file for logging The indicator changes to LOGGING when data logging commences It is blank at all other times User Logon State Displays the current access level USER CAL or CFG DyneSystems Cell Assistant Status Bar DPD 008 02 e Copyright DyneSystems Inc 13 5 CHAPTER 13 DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc APPENDIX 1 System Channels The following system function channels are available in Cell Assistant see Channels chapter J607 Correction Factor Dew Point This function calculates the SAE J607 correction factor for torque and power using dew point as the measure of humidity Where 101 t 273 Correction Factor Es B E 288 6 17 2694 tas Le gt E 0 61078 e d Input Description B Barometric Pre
104. us Contact Dyne Systems with any questions Note Based on the device configuration settings the device driver creates a set of uniquely named physical device channels Ultimately virtual channels will be created from these physical channels Thus it is absolutely IMPERATIVE that the device configuration be correctly established at the start of your TestSystem design and not be changed afterward This warning especially applies to PLC s Changing the PLC configuration could cause a dangerous re mapping of all I O bit functionality between the PLC and your TestPlans Device Setup OCS351 Diagnose Settings Pot PLC Registers en ze E Register Names 71000 to XT1059 Oty en EO T11200 to 271259 Fo ho Digital Inputs n3 8 B e ime Digital Outputs R1000 to R1009 e e e Analog Inputs 5 ce e Analog Dutputs ZR1200 to ZR1203 Slave Address Sample Rate 10 Hz Cancel DyneSystems Cell Assistant Configuring a Device 4 5 DPD 008 02 e Copyright DyneSystems Inc CHAPTER 4 Hardware Devices 3 4 Device Diagnostics The driver for most devices includes one or more diagnostic dialogs providing simplified access to data in the connected device These diagnostics are independent of the Cell Assistant data acquisition subsystem and are extremely useful for basic device testing A sample dialog for a PLC is shown below For example this dial
105. y HD in the first column The first line documents when the file was opened and which format was used The second line lists the channel names The third line lists the units for each channel An optional NoHeaderFlag parameter allows a data file to be opened without adding the three header lines to the data file This allows the creation of numbers only data files that may be easier to analyze later on To prevent the logging of the header lines set the NoHeaderFlag to NoHeader or NH If this parameter is omitted the default action is to always log the header lines 5 2 Close This method closes a currently open data file The syntax of the Close method is shown below FormatName Close NoHeaderFlag The following are valid uses of the Close method Formatl Close Format1 Close NH 8 4 Using Data File Formats in a TestPlan DyneSystems Cell Assistant DPD 008 02 e Copyright DyneSystems Inc Chapter 8 Data Files When the Close method executes Cell Assistant automatically writes one line of header data identified by HD in the first column This line records the format of the data file being closed as well as the time and date An optional NoHeaderFlag parameter allows the data file to be closed without adding the header line to the data file This allows the creation of numbers only data files that may be easier to analyze later on To prevent the logging of the header line set the NoHeade
106. yed channels will be exported Typically check the All checkbox to export all channels in the TestSystem 2 Sortthe displayed channel list as the channels will be exported in the same order as they are displayed Sorting by Type is typically the most useful so click the Type column header button Click the Export button An Export Channels pop up dialog appears Modify the default filename as needed e g change NNN to a valid number and click the Save button Previously exported channels can be re imported by clicking the Import button A warning dialog appears explaining the dangers of importing channel data from an external file If the imported file was previously exported from Cell Assistant and not externally modified in any way import errors are extremely unlikely Dismiss the warning dialog select the import file and click the Open button All channels specified in the file will be merged into the existing channel list If errors occur during the import process it is extremely important to repair the file and re import else the TestSystem may be left in an unusable state Note When importing channels from a file new channels will be added as needed and existing channels will be modified as needed All other currently existing channels remain as is No channels will be deleted 4 0 Channel Types Virtual channels fall into one of two categories 1 physical device based cha