Edan SE-12 Express ECG User Manual
Contents
1. 36 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application 2 Inthe Work Mode Setup window press Tab or Shift Tab to move the cursor to a list box or dropdown Press the Up or Down arrow to highlight an option 3 In the Work Mode Setup window press Tab or Shift Tab to move the cursor to a textbox Fill in the selected textbox 4 Press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm 5 Press ESC to cancel the operation or press Tab or Shift Tab to move the cursor to the Cancel button and then press to cancel the operation 3 7 About the File Manager screen When the main screen is displayed press the function key F7 below File to open the File Manager screen Press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Then press the function key F7 below Return to return to the File Manager screen1 Press the function key F7 below Return on the File Manager screen to return to the main screen oe 5 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application File Manager 1 200 Name ID Time Mode Marry Johnson 00i 2010 04 08 10 50 26 AUTO Mrans AI Export All Del All Select Search Irhport Return A B C D E F G Figure 3 6 File Manager screen1 File Manag
2. 11 10 3 Backing Up Settings Press Tab or Shift Tab to move the cursor to the Back up Settings button in the System Maintenance window and then press to back up the system settings to the ECG 11 10 4 Loading Backup Settings Press Tab or Shift Tab to move the cursor to the Load Backup Settings button in the System Maintenance window and then press to load the backup settings from the ECG 11 10 5 Printing System Settings Press Tab or Shift Tab to move the cursor to the Record System Settings button in the System Maintenance window and then press to print the system settings Pressing this button again can stop printing system settings 11 10 6 Loading Factory Settings Press Tab or Shift Tab to move the cursor to the Load Factory Settings button in the System Maintenance window and then press to restore the factory settings shown in the following table 144 SE 12 Series Electrocardiograph User Manual Table 11 1 System Setup Defaults System Setup Resting ECG Setup Default 1 Mode Options Auto Manual Rhythm 2 Manual Style 6 channels 3 Auto Display Style 6x2 4 Rhythm Style Three Leads 5 Sampling Mode Real time Sample 6 Duration Periodic Sample 60 min 7 Interval Periodic Sample 1 min 8 Preview Off 9 Auto Extend Record Off 10 AC filter On 11 EMG filter Off 12 DFT filter 0 67Hz 13 Lowpass filter 100Hz 14 Record Styl
3. 1 Press the casing button downwards and remove the casing to open the recorder 2 Remove the remainder paper from the paper tray if necessary 3 Take off the wrapper of the new folded paper and then put it in the paper tray zi 4 Pull the paper out with the grid side facing the thermal print head and replace the casing on the recorder 43 SE 12 Series Electrocardiograph User Manual Operation Preparations 5 6 7 Press down the recorder casing firmly To select Paper Marker Press Q on the keyboard to turn on the unit After the main screen is displayed press the function key F6 below Setup to display the System Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Record Info on the System Setup screen press to open the Record Info Setup window Press Tab or Shift Tab to move the cursor to the Paper Marker list box and then press the Up or Down arrow to highlight No or Yes Press to confirm and then the System Setup screen appears Press ESC to return to the main screen Advance the recorder paper When the main screen is displayed if Paper Marker is set to Yes you can press Tab O to advance the recorder paper to the next black marker if Paper Marker is Tab O Tab O set to No you can press to advance the paper for 2 5cm Press again to stop advancing the paper Loading Replacing Process of R
4. 11 7 6 Setting QRS Volume Press Tab or Shift Tab to move the cursor to the QRS Volume list box in the Display amp Sound Setup window and then press the Up or Down arrow to highlight an option When an R wave is detected there is a sound You can set QRS Volume to Low Medium High or Off When it is set to Off there is no sound when an R wave is detected 11 8 Date amp Time Setup NOTE Please set DATE amp TIME correctly when it s the first time you use the electrocardiograph Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Date amp Time on the System Setup screen press to open the Date amp Time Setup window 138 SE 12 Series Electrocardiograph User Manual System Setup Date amp Time Setup it 105 20 10 12 o0 Jor 24 Hours Figure 11 10 Date amp Time Setup window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 8 1 Setting Date and Time Press Tab or Shift Tab to move the cursor to the Date or Time textbox in the Date amp Time Setup window and then input the date or the time manually The time will be displayed on the main screen and the date and the time will be printed in the ECG reports 11 8 2 Setting Date Mode Press Tab or Shift Tab to move the cursor to the Date Mode list box in the Date amp Tim
5. EDANUSA SE 12 Series Electrocardiograph Version 1 0 C ou About this Manual P N 01 54 455421 10 Release Date November 2011 Copyright EDAN INSTRUMENTS INC 2011 All rights reserved Statement This manual will help you understand the operation and maintenance of the product better It is reminded that the product shall be used strictly complying with this manual User s operation failing to comply with this manual may result in malfunction or accident for which EDAN INSTRUMENTS INC hereinafter called EDAN can not be held liable EDAN owns the copyrights of this manual Without prior written consent of EDAN any materials contained in this manual shall not be photocopied reproduced or translated into other languages Materials protected by the copyright law including but not limited to confidential information such as technical information and patent information are contained in this manual the user shall not disclose such information to any irrelevant third party The user shall understand that nothing in this manual grants him expressly or implicitly any right or license to use any of the intellectual properties of EDAN EDAN holds the rights to modify update and ultimately explain this manual Product Information Product Name Electrocardiograph Model SE 12 SE 12 Express Responsibility of the Manufacturer EDAN only considers itself responsible for any effect on safety reliability a
6. Tab to move the cursor to the FTP Path FTP User Name and Password textboxes and then fill in these textboxes 11 5 5 Setting IP Addresses To Set Server IP Set the Server IP item to the IP of the PC 133 SE 12 Series Electrocardiograph User Manual System Setup To Set Local IP For the cross network transmission set the first two sections of the Local IP item to the first two sections of the IP of the PC Set the third section of the Local IP item to the network segment of the electrocardiograph which depends on the configuration of Router The last section of the Local IP item can be set at random For the same network transmission set the first three sections of the Local IP item to the first three sections of the IP of the PC The last section of the Local IP item can be set at random but it can t be the same as the last section of the IP of the PC To Set Gateway Set the first three sections of the Gateway item to the first three sections of the IP of the PC The last section of the Gateway item must be set to 1 To Set Subnet Mask You can set Subnet Mask in the Transmission Setup window Commonly Subnet Mask is set to 255 255 255 000 11 6 Lead Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Lead on the System Setup screen press to open the Lead Setup window 134 SE 12 Series Electrocardiograph User Manual System Setup Lead Setu
7. analyzed automatically or stored 11 3 2 Setup 2 Press F1 or F2 to switch to the Setup 2 tab Record Info Setup Cancel Figure 11 5 Record Info Setup2 Press Tab or Shift Tab to move the cursor to an item and then press Spacebar to select or deselect the item 126 SE 12 Series Electrocardiograph User Manual System Setup Auto Record Info includes Patient Info Position Marker Analysis Template Measure Minnesota Code and Baseline Adjustment When Patient Info Position Marker Analysis Template Measure or Minnesota Code is selected it will be printed in the ECG reports When Baseline Adjustment is set to Auto the baselines of the lead groups are adjusted respectively When Baseline Adjustment is set to Horizontal the baselines of the lead groups are adjusted simultaneously and the baselines of the leads in the same row are on the same line R R Record Info includes R R Histogram R R Waveform and R R Interval List When R R Histogram R R Waveform or R R Interval List is selected it will be printed in the ECG reports Grid of Report includes Thermal Report and USB Report When Thermal Report is selected the grid will be printed while printing ECG reports with the thermal recorder When USB Report is selected the grid will be printed while printing ECG reports with a USB printer NOTE 1 The items of Auto Record Info are available only in the auto mode and Template and Position Ma
8. l l 2 5cm Press again to stop advancing the paper 4 3 Preparing the Patient 4 3 1 Instructing the Patient Before attaching the electrodes greet the patient and explain the procedure Explaining the procedure decreases the patient s anxiety Reassure the patient that the procedure is painless Privacy is important for relaxation When possible prepare the patient in a quiet room or area where others can t see the patient Make sure that the patient is comfortable The more relaxed the patient is the less the ECG will be affected by noise 4 3 2 Preparing the Skin Thorough skin preparation is very important The skin is a poor conductor of electricity and frequently creates artifacts that distort the ECG signals By performing methodical skin preparation you can greatly reduce the possibility of noise caused by muscle tremor and baseline drift ensuring high quality ECG waves There is natural resistance on the skin surface due to dry dead epidermal cells oils and dirt To Prepare the Skin 1 1 Shave hair from electrode sites if necessary Excessive hair prevents a good connection 2 Wash the area thoroughly with soap and water 3 Dry the skin with a gauze pad to increase capillary blood flow to the tissues and to remove the dead dry skin cells and oils 46 SE 12 Series Electrocardiograph User Manual Operation Preparations 4 4 Connecting the Patient Cable to the Electrocardiograph and Electrodes WARN
9. Tab to move the cursor to the Manual Style list box in the Work Mode Setup window and then press the Up or Down arrow to highlight 3 channels 6 channels or 12 channels When Manual Style is set to 3 channels ECG waves of 3 leads are displayed and printed in the manual mode When Manual Style is set to 6 channels ECG waves of 6 leads are displayed and printed in the manual mode When Manual Style is set to 12 channels ECG waves of 12 leads are displayed and printed in the manual mode 11 1 3 Selecting Rhythm Style Press Tab or Shift Tab to move the cursor to the Rhythm Style list box in the Work Mode Setup window and then press the Up or Down arrow to highlight Single Lead or Three Leads When Rhythm Style is set to Single Lead in the rhythm mode 60s ECG waves of the appointed single rhythm lead will be printed When Rhythm Style is set to Three Leads in the rhythm mode 20s ECG waves of three appointed rhythm leads will be printed 11 1 4 Selecting Auto Display Style Press Tab or Shift Tab to move the cursor to the Auto DispStyle list box in the Work Mode Setup window and then press the Up or Down arrow to highlight an option When the auto display style is set to 3x4 ECG waves of 12 leads are displayed in 4 groups of 3 117 SE 12 Series Electrocardiograph User Manual System Setup When the auto display style is set to 3x4 1R ECG waves of 12 leads are displayed in 4 groups of 3 with the ECG wave o
10. 3 channel ECG waves are displayed on the main screen of the exercise test When Display Style is set to 4x3 12 channel ECG waves are displayed in 3 groups of 4 on the main screen of the exercise test When Display Style is set to 6x2 12 channel ECG waves are displayed in 2 groups of 6 on the main screen of the exercise test When Display Style is set to 12x1 12 channel ECG waves are displayed on the main screen of the exercise test 166 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional NOTE When the main screen of the exercise test is displayed pressing the Up or Down arrow on the keyboard can switch the display styles When the display style is 3x1 pressing the Left or Right arrow on the keyboard can switch the lead groups 2 Speed Unit You can set Speed Unit to mph or km h 3 Post J Post J is the length after J point of ST segment You can set Post J to Oms 20ms 40ms 60ms or 80ms NOTE J point is the connection point between the end of QRS complex and the start of ST segment It is the standard point to fix the position of ST segment Please select a proper option based on the patient s actual ECG waves 4 Device Type Device Model BP Monitor Press Tab or Shift Tab to move the cursor to the Device Type list box and then press the Up or Down arrow to highlight Treadmill or Ergometer Press Tab or Shift Tab to move the cursor to the Device Model list box
11. 3G A DOULTHEsS VST Setup s re a Sec Sanat teased neat is oe euied Selena ay a ln eid ood a a tel os 35 3 7 About the File Manager screen iu scaisiann 2s oe ieys totic NA ea tie aa ata eee 37 Chapter 4 Operation Preparations sesssesesocesooesooessocsssecesocesooesoocssocessocesocesoosesocesseessocesoosssosess 40 4 T Power ad AT E a e a e a a a a e aaas 40 4 2 Loading Replacing Recorder Paper ss sesessssessssseesseesesresseesesresstesesersseessessessressessessees 42 AS Preparing th Patiehtesersriesisto neotenie eot Aaa R a AAE a AERA EA oaea o haben 46 4 3 istr ctine the Patent isceats dss sa aais vores autendveeenddadavsoneciaat a a a a 46 4 3 2 Preparing th SKIN aroi vids eo E E E E A AE E 46 4 4 Connecting the Patient Cable to the Electrocardiograph and Electrodes cceeeeeeeeees 47 4 5 Attaching Electrodes to the Patient for Resting ECG sssssesessssessesssssressessrssressessessrssees 48 AD Lead Placement iccco ceae retdsats aean o a a a E Ra 48 4 5 2 Electrode Placements arineniaca e a a E E A aa ai 50 4 6 Attaching Electrodes to the Patient for Exercise ECG ccccecsceseseeeseeceteceneeeeeeeeeeesaeens 53 HI 4 1 Inspection before Power Ofisni nsina ionii i AA AEK T EEEE N RS AAEE EOS 55 Chapter 5 Turning on the Electrocardiograph sessesesseesessossesossossesossossescossesossossesossossesossssse 56 Chapter 6 Entering Patient Information esssesssecssecssecesocesoosesscessccssoc
12. 7d aacenectaesatiid duets wand dace 179 15 3 2 Recorder Paper scspnioninenmn anaa a a e a E NE 180 153 3 VISUAL mspecti omanneen E E T e R E T E a yeas 181 15 3 4 Maintenance of the Main Unit and the Patient Cable nssnssssesneeseesseeseesssessesesseesee 181 Chapter 16 Accessory Listscsssoiocss oreas eissoes esenee eresas rio aaa eie ioeo osae soroa extacctanneaaeenne 184 Chapter 17 Warranty amp Service e sseessecssececoscccocssoccsococsocccosecoocscooesococsscccoseccoessseesocessssesssses 186 VTL WAIT ATL vs sc cued nana ae a E a E E E A R EE Gdesten anes 186 17 2 Cont ct informatione oeei a a a a a a a e a e tama 186 Appendix 1 Technical Specifications eessoessoessseessocesocesooecsocessocessccesocesocescocssocsssecssocesocsesosess 187 All Safety Specifications receios dea E a nadia EAE E ander E Aa et 187 A1 2 Environment Specifications essssesseseesseessessresseesresrtsstesresrtsstessesrtsstessessresesseesresseesee 187 A13 Physical SEC ICAU ONS 5 series sino Saws cnet a a E E Ba Suara sa aniuen 188 A1 4 Power Supply Specifications 25 52 3935 cesses Cee ae sence cua see ag eee eSaues oeaasecde Ses 188 ALS Performance Specifications iscsi seisskelecsakcveseapvisd cece cera auvoecdsdsachevvncevcs a i 189 Appendix 2 EMC Information oss esii i cecssgens svceaassnecdcunceceesns lt veedesecee ocasevcgnncsvedoassdecsvucepeteconesyecsieed 191 Appendix 3 Abbreviation eessoessocsssecssecssocesooessocesocessocesoce
13. A E lasdecuachas eaten 157 123 Exercise Testienedrin nae n a Aaa sees Galan Ai ee Cadena ia ead 164 12 4 System Setup for Exercise Test uscd rsscaatatcceatedceariasncuaeme eee baienopcm ness 165 12 4 1 General Information OCLUP ves CasiteAvi fos Nat deacon fe aedeclenace ds tesaue dade anand esau a daeer bes 165 12 4 2 Record Information Setup ya sinnncas estas ada en cesses cctmrainecd at eaanee tavaren remo tatordencdetasen meso vteese 168 12 4 3 Protocol WIAA REE ahr enrian uaaa a AA EA A A a RR E 170 Chapter 13 Turning off the Electrocardiograph cssscssssscsssssccsssscesssccsssecessssccessscscoess 174 Chapter 14 Hint Information o soessessossosssessossoossessossoossessossooesosssesoossosssesoossosssessossosssesssssocese 175 Chapter 15 Cleaning Care and Maintenance seessseessecssecescocesocesoocsssccssecesooesoossoocesoeessecesosee 177 VS CNG AIM 1 aera e e e a ous es e e onl a e E A RG 177 15 1 1 Cleaning the Main Unit and the Patient Cable essesseseesseseesesseseesesseesesseseesesseseese 177 15 1 2 Cleaning the Reusable Electrodes wy z2isacsh5assiess agieCeadasddnauoeiacasuandunatsansndanlseisnaoaeedcauaaes 177 15 1 3 Cleaning the Print Head casei attest te lene at hanet aaa Std E a 178 15 1 4Cleaning the Treadmill sinnn a E E a a E a 178 15 2 Disinfection snn ann ann a a a a a aa a a babs oo see tds 178 15 3 Care and Maintenance sioneer a a E A E EER lees 179 15 3 1 Recharge and Replacement of Battery i 2
14. Codes European American Electrode Connectors Identifier Color Code Identifier Color Code Right arm Right deltoid R Red RA White Left arm Left deltoid L Yellow LA Black Right leg Upper leg as PEER Nor RF Black RL Green close to torso as possible Left leg Upper leg as nen f F Green LL Red close to torso as possible Chest 1 C1 White Red vil Brown Red Chest 2 C2 White Yellow v2 Brown Yellow Chest 3 C3 White Green V3 Brown Green Chest 4 C4 White Brown V4 Brown Blue 48 SE 12 Series Electrocardiograph User Manual Operation Preparations Chest 5 C5 White Black V5 Brown Orange Chest 6 C6 White Violet V6 Brown Violet As the following figure shows the positions of chest electrodes on the body surface are C1 Fourth intercostal space at the right border of the sternum C2 Fourth intercostal space at the left border of the sternum C3 Fifth rib between C2 and C4 C4 Fifth intercostal space on the left midclavicular line C5 Left anterior axillary line at the horizontal level of C4 C6 Left midaxillary line at the horizontal level of C4 i R L Cg Re Q g Cs j j T a j e e142 C3 R L C4 C5 c6 N Fe 49 SE 12 Series Electrocardiograph User Manual 4 5 1 2 NEHB Placement The electrodes positions on the body surface are shown in the following table and figure f Al Operation
15. Diagnosis Information Report Confirmed by Current Date and Current Time 6x2 1R ECG waves 0 67 100Hz 0 67Hz DFT Filter 100Hz Lowpass Filter 25mm s Paper Speed er ee AC50 50Hz AC Filter 10mm mV Gain SE 12 Series Electrocardiograph User Manual Printing ECG Reports 2 5s I1r 12 leads are printed in 2 groups of 6 and every group is printed for about 5s with one rhythm lead at the bottom simultaneously Institution Name SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm Version Number Quick Mode 02 06 2010 16 52 40 ID 001 Age Name Marry Johnson Bees EN al E AEAEE E wanna a E 25 Years REEERE EARN EEEE AEA A fe 7N j g 7 a vai Fas te i Nr A sf co At Ft AN A V3 i N la ig mmn J sn aE E E A aVR 5 i v4 IA EJA E IEA Hi se SHE Gl al ES Tae es ee fe nap nanasan an aa n aa 1 1 j ma aVL pd ERS URU GO ERE d poh a Qt Newer VS tA a e re Po SI VE Lany ae A an See Vo Fii J I pai SEEE Pt FED Fea PEER FETH FERN EB Pa j j i f I oy San BEEE oe Sg EEEE EY P A A LA J a al Qe ee BS B a IL as a 0 67 100Hz AC50 25mm s 10mm mV 2 5s 1r Institution Name SE 12Express V1 8 SEMIP V1 5 a 78 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 02 06 2010 16 52 52 ID 001 Name Marry John
16. ECG report in the R R analysis mode Figure a shows Current Date amp Current Time Patient Information Name ID Gender Age Height Weight Measuring Time Total Beat Number HR Heart Rate RR Avg Interval Average RR interval RR Max Interval Maximum RR interval RR Min Interval Minimum RR interval Max Min Ratio of Maximum RR interval to Minimum RR interval 86 SE 12 Series Electrocardiograph User Manual SDNN Standard Deviation of Normal to Normal Intervals RMSSD Root Mean Square Successive Difference RR Histogram RR Trend Figure b shows Current Date amp Current Time Patient Information Name ID Age Gain Speed Filter fl 1mV calibration mark II Lead name 180s compressed ECG wave of Lead II Figure c shows All the RR interval values within the measuring time eT Printing ECG Reports Printing ECG Reports SE 12 Series Electrocardiograph User Manual 8 6 5 ECG Reports Printed by the USB Printer SIA GINS 8 1A Ss2sdxqzI ds 414 5S42 Awww sjwwsz OSOW ZHOOI ZHL9 0 4q pewsyuog yoday AW Z88 0 9EL 0 due ZAS 9AU AW gLS I dwe 1as sau AW 9ES 0 ZpO 1 dwe TAS SAU o SISHISS SKE L SUO d SU pSEJpSE 30 QLO LO e100 POON Gs a ee eee aoa sw pLi 1 s 13M wqu snus 008 su p mad ayewag Japuag sIeaA Z aBy uonewsozu stsoUBEIG Wda 09 YH uosuyor Asse yy aweN b2 02 LT 0102 90 20 100 dl LYOdda DDA JWLeN uonnNnyysug 88 SE 12 S
17. Electrocardiograph User Manual About the Electrocardiograph Application Name Explanation A NOTE Only if the stress ECG function is activated can these keys be available Pretest When the main screen is displayed press this key to display the main screen of the exercise test When the main screen of the exercise test is displayed press this key to enter the pretest phase The length of the pretest phase is not fixed Exercise Press this key to enter the exercise phase In the exercise phase press this key to enter the next stage of the exercise phase Recovery Press this key to enter the recovery phase In the recovery phase press this key to enter the next stage of the recovery phase Test end Press this key to display a pop up dialog box and then you can decide whether the exercise test should be terminated Enter BP Press this key to display the Input BP dialog box and then enter the BP values manually Recall During the exercise test press this key to review 10s data and print out the 12 channel ECG report of the reviewed 10s data 12 Id Medians During the exercise test press this key to sample 10s data and print out the 12 channel ECG report of the sampled 10s data During the exercise test press this key to print out the average template report Comment Press this key to display the Comment dialog box and then you can annotate in th
18. Electrocardiograph User Manual Transmitting ECG Data Automatically 3 Press Tab or Shift Tab to move the cursor to the Activate button after the function to be activated Press to open the Activate Password window Enter the password and press to activate the function NOTE Please contact local distributors to get the service password and the activating password 2 Set file format to SCP FDA XML PDF When the main screen is displayed press the function key F6 below Setup to open the System Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to File press to open the File Setup window Press Tab or Shift Tab to move the cursor to File Format and then press the Up or Down arrow to select a format File Setup Cancel 3 Transmit ECG data in SCP FDA XML PDF format through the net cable 1 Connect the electrocardiograph to the network of the PC with an Ethernet cable recommended by the manufacturer If the wireless AP transmission is used connect the PC to the server wireless AP and connect the electrocardiograph to the client wireless AP Only the wireless AP recommended by the manufacturer can be used 2 Input the correct FTP path FTP user name and password Set Auto Transmission to On and Transmission Mode to Ethernet Set the IP addresses For details please refer to Section 9 1 2 Transmitting ECG Data in DAT Format Through Net Cable 98 SE 12 Series
19. FTP port is 21 3 Input the correct FTP path FTP user name and password Set Transmission Mode to Ethernet Set the IP addresses For details please see Section 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format to the PC Through Net Cable 4 Press the function key F7 below File to display the File Manager screen1 5 Press the function key F1 below Trans All to transmit all the files to the PC After all the files are transmitted the following hint will pop up HINT Transmitting succeeds 6 Or press the Up or Down arrow to highlight a file on the File Manager screen and then press the function key F4 below Select to select the file and display the File Manager screen2 Press the function key F3 below Trans to transmit the selected file to the PC 10 2 Exporting Files to the U Disk 1 Insert the U disk recommended by the manufacturer to USB socket 2 of the electrocardiograph 2 When the main screen is displayed press the function key F7 below File to open the File Manager screen 3 Press the function key F2 below Export All to export all the files to the directory of ECGDATA ECG X Export Examination Date and Time of the U disk 4 Or press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Press the function key F4 below Export to export the selected file to the directory of ECGD
20. Failure on the part of the responsible individual hospital or institution employing this equipment to implement a satisfactory maintenance schedule may cause undue equipment failures and possible health hazards 1 Main Unit Avoid excessive temperature sunshine humidity and dirt Put the dustproof coat on the main unit after use and prevent shaking it violently when moving it to another place Prevent any liquid from seeping into the equipment otherwise the safety and the performance of the electrocardiograph can not be guaranteed 2 Patient Cable Integrity of the patient cable including the main cable and lead wires should be checked regularly Make sure that it is conductible Do not drag or twist the patient cable with excessive stress while using it Hold the connector plug instead of the cable when connecting or disconnecting the patient cable Align the patient cable to avoid twisting knotting or crooking in a closed angle while using it Store the lead wires in a big wheel to prevent any people from stumbling Once damage or aging of the patient cable is found replace it with a new one immediately 182 SE 12 Series Electrocardiograph User Manual Cleaning Care and Maintenance 3 Reusable Electrodes Electrodes must be cleansed after use and make sure there is no remainder gel on them Keep suction bulbs of chest electrodes away from sunshine and excessive temperature After long term use the s
21. Recorder paper provided by the manufacturer should be used Other paper may shorten the life of the thermal print head The deteriorated print head may lead to illegible ECG reports and block the advance of the paper Storage Requirements Recorder paper should be stored in a dry dark and cool area avoiding excessive temperature humidity and sunshine Do not put the recorder paper under fluorescence for a long time Make sure that there is no polyvinyl chloride or other chemicals in the storage environment which will lead to color change of the paper 180 SE 12 Series Electrocardiograph User Manual Cleaning Care and Maintenance Do not overlap the recorder paper for a long time or else the ECG reports may trans print each other 15 3 3 Visual inspection Perform a visual inspection of all equipment and peripheral devices daily If you notice any items that need repair contact a qualified service engineer to make the repairs Check the case and display screen for cracks or other damage Regularly inspect all plugs cords cables and connectors for fraying or other damage Verify that all cords and connectors are securely seated Inspect keys and controls for proper operation 15 3 4 Maintenance of the Main Unit and the Patient Cable CAUTION Besides the maintenance requirements recommended in this manual comply with local regulations on maintenance and measurement The following safety chec
22. To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the 12 channel electrocardiograph is used exceeds the applicable RF compliance level above the 12 channel electrocardiograph should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the 12 channel electrocardiograph 2 Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 194 SE 12 Series Electrocardiograph User Manual EMC Information Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM for EQUIPMENT or SYSTEM that is not LIFE SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the 12 channel Electrocardiograph The 12 channel electrocardiograph is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the 12 channel electrocardiograph can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the 12 channel electrocardiograph as recommended below according to the maximum output power of the communications equipment R
23. Turn OFF Computer 61 SE 12 Series Electrocardiograph User Manual Entering Patient Information c In the Computer Management window click on Device Manager Right click on HID Keyboard Device and then select Properties in the pop up menu File Action View Help es 2h 5 88 o gt g x Computer Management Local a System Tools Task Scheduler Event Viewer Shared Folders amp Local Users and Groups Performance 4 Storage fey Disk Management Es Services and Applications 4 edan PC JE Computer Disk drives E Display adapters 43 DVD CD ROM drives ss Human Interface Devices q IDE ATA ATAPI controllers s Z Keyboards amp HID Keyboard Device F Mice and other pe Monitors amp Network adapters IF Ports COM amp LP 1B Processors Sound video and g Jm System devices Update Driver Software Uninstall Scan for hardware changes Universal Serial Bus controllers d Click on the Details tab in the HID Keyboard Device Properties window View the vector ID VID and the product ID PID Take the following figure for example the vector ID is 04B4 and the product ID is 0100 HID Keyboard Device HID_DEVIC HID_DEVICE_SYSTEM_ KEYBOARD HID_DEVICE_UP 0001_U 0006 E 62 SE 12 Series Electrocardiograph User Manual Entering Patient Information 4 Press ESC to return to the main scre
24. a clean soft cloth first 2 Take suction bulbs and metal cups of chest electrodes apart and take clamps and metal parts of limb electrodes apart 177 SE 12 Series Electrocardiograph User Manual Cleaning Care and Maintenance 3 Clean them in warm water and make sure there is no remainder gel 4 Dry the electrodes with a clean dry cloth or air dry naturally CAUTION Do not clean the unit and accessories with abrasive fabric and avoid scratching the electrodes 15 1 3 Cleaning the Print Head To clean the print head 1 Open the recorder casing and remove the paper 2 Wipe the print head gently with a clean soft cloth damped in 75 alcohol For stubborn stain soak it with a little alcohol first and wipe it off with a clean soft cloth 3 After air drying load the recorder paper and shut the recorder casing Dirty and soiled thermal print head will deteriorate the printing definition So it should be cleaned at least once a month regularly CAUTION Prevent the detergent from seeping into the main unit while cleaning Do not immerse the unit or the patient cable into liquid under any circumstances 15 1 4 Cleaning the Treadmill For details on cleaning the treadmill please refer to Treadmill User Manual 15 2 Disinfection Disinfection of the main unit is not necessary need in daily maintenance it is only necessary in operating room In that case please use hospital standard disinfectant NOTE Clean and disi
25. and then press the Up or Down arrow to specify the device model Press Tab or Shift Tab to move the cursor to the BP Monitor list box and then press the Up or Down arrow to highlight Off Tango or In Ergometer NOTE 1 You should test whether the treadmill is controlled by SE 12 Express well when SE 12 Express is connected to the treadmill for the first time 2 Do not stand on the treadmill when testing it for the first time 3 Before the exercise test be sure to be familiar with the user manual of the treadmill or the ergometer 4 If you have any questions about the operation please contact us or your local distributor 5 Normal BP Range You can set the normal range of the systolic diastolic blood pressure If the patient s blood pressure values exceed the normal BP ranges the system will give a hint 167 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional 6 Max Predicted HR and Target HR The following formulas are applied to calculate the target heart rate Max Predicted HR 220 Age Target HR Max Predicted HR 85 NOTE 220 and 85 are default values and you can modify them in different situations 12 4 2 Record Information Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Record Info on the System Setup screen press to open the Record Info Setup window Record Info Setup Figu
26. auto mode when Record Style is set to 6x2 ECG waves of 12 leads are printed in 2 groups of 6 In the auto mode when Record Style is set to 6x2 1R ECG waves of 12 leads are printed in 2 groups of 6 with the ECG wave of one rhythm lead on the bottom of the ECG reports In the auto mode when Record Style is set to 12x1 ECG waves of 12 leads are printed simultaneously 11 3 1 2 Selecting Recording Mode Press Tab or Shift Tab to move the cursor to the Record Mode list box on the Setup 1 tab and then press the Up or Down arrow to highlight Save Paper or Quickly When Record Mode is set to Save Paper 10s after pressing the START STOP key on the main screen an ECG report is printed The patient information measure information interpretation and ECG waves are printed on the same paper When Record Mode is set to Quickly pressing the START STOP key on the main screen to begin printing an ECG report immediately the patient information measure information interpretation and ECG waves are printed on two pieces of paper NOTE 1 In the auto mode only when Sampling Mode is set to Real time Sample Quickly is available 2 When Record Style is set to 3x4 3x4 1R or 3x4 3R only Save Paper is available When Record Style is set to 12x1 only Quickly is available 11 3 1 3 Selecting Recording Sequence Press Tab or Shift Tab to move the cursor to the Record Sequence list box on the Setup 1 tab and then press the Up or Down
27. be triggered automatically When Sampling Mode is set to Periodic Sample first you should set Duration and Interval For example if Interval is set to 2 min and Duration is set to 24 min after pressing the START STOP key the printing will be performed every two minutes and come to 12 times NOTE 1 There is no saving exporting or transmitting in the Periodic Sample mode 2 ID and patient information will not be changed while carrying out the periodic printing 118 SE 12 Series Electrocardiograph User Manual System Setup 11 1 6 Setting Interval and Duration Press Tab or Shift Tab to move the cursor to the Duration and Interval textboxes in the Work Mode Setup window and then input the duration and the interval manually In the auto mode when Sampling Mode is set to Periodic Sample if Interval is set to 2 min Duration is set to 24 min after pressing the START STOP key the printing will be performed every two minutes and come to 12 times 11 1 7 Selecting Preview Function Press Tab or Shift Tab to move the cursor to Preview in the Work Mode Setup window and then press the Up or Down arrow to highlight Off or On When Preview is set to On the preview screen will appear after you press the START STOP key in the auto or off mode When Preview is set to Off the preview screen will not appear after you press the START STOP key 11 1 8 Selecting Auto Extend Record Press Tab or Shift Tab to move the curso
28. before operation 2 Ensure that the conductive parts of electrodes and associated connectors including neutral electrodes do not come in contact with earth or any other conducting objects CAUTION The disposable electrodes can only be used for one time 54 SE 12 Series Electrocardiograph User Manual Operation Preparations 4 7 Inspection before Power On In order to avoid safety hazards and get good ECG records the following inspection procedure is recommended before power on and operation 1 Environment Make sure that there is no electromagnetic interference source around the equipment especially large medical electrical equipment such as electrosurgical equipment radiological equipment magnetic resonance imaging equipment etc Turn off these devices when necessary Keep the examination room warm to avoid muscle tremor voltages in ECG signals caused by cold 2 Power Supply Ifthe mains supply is used please check whether the power cord is connected to the unit well The grounded three slot outlet should be used When the battery capacity is low recharge the battery before use 3 Patient Cable Make sure that the patient cable is connected to the unit firmly and keep it far away from the power cord 4 Electrodes Make sure that all electrodes are connected to lead wires of the patient cable correctly Ensure that the chest electrodes do not contact 5 Recorder Paper Ensure tha
29. from U Disk i cesducsskgobasasiesoacdiscesdeadoctausannasselbesaceees 144 11 10 3 B cking Up Settings f5s2 sesaciegbss rnnt rai RAA EER AA RN a aE 144 11 10 4 Loading Backup Settings ns sessseesesseesseeseeseesseesresresseesresresstesseserssressessrssressessessees 144 11 10 5 Printing System Settings sseseseseeseeseesseeseesessseesresersstessessressessrsseesseestesresseeseseessee 144 1 10 56 Loading Factory Setitis ons ook teasn cred cece saceses cwsenaddaeds a a a er aledes 144 11 10 7 Setting System Password c0cssrieccac a ceustoractivasieces are teats eerie aeadetivens 152 LL Other Setup cs wicatause a Gace Aas hue Geode aoa ota 153 11 11 1 Entering Institution yous asc cis Ze ce haace aac oh Gateceanas oa eedeemae dees a cenesenieer eo uneeeneaeenteeeuawnecamenn tees 153 11 11 2 Sel cting a Langya gt noe Tes Noe n eaa tlne leg Mee a outta Mee Tou 2 aden Bel 153 We TTS Selecting Caps LOCK iceren ine das i vpnateenl E E RE e 154 11 11 4 S tting External Tipit sisstin a iaa A ER AS ESR KRN Eain 154 ILTIS Setting External Ua eet kn cS gk Faia tat Sa Saud Fae a 154 VI 11 11 6 Setting Pacemaker Detection Sensitivity cssessscstscerceseesseessesesensetsceseesseeeees 155 Chapter 12 Operation Instructions for Exercise ECG Configurable for SE 12 Express 156 12 1 Activating Exercise ECG Punenoniins ac scecteassit 2 Seesivatenscbaaiessnshvauaeeelivbaun autamaauenentees 156 12 2 Operation Preparation seinere a E
30. function key F1 below Patient to open the Patient Information window 2 Press Tab or Shift Tab to move the cursor to the Name textbox 3 Press on the keyboard to erase the typed information 4 Press the letter or number keys on the keyboard to input patient name Press Fn and a letter key to input the special character in the top right corner of the key Press Shift o and a number key to input the special character in the top right corner of the key For example press Fn a to input and press Shift 3 to input If Caps Lock is set to Off pressing Shift o and a letter key can input a capital letter If Caps Lock is set to On pressing Shift Le and a letter key can input a lowercase letter 5 Press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm 6 Press ESC to cancel the operation or press Tab or Shift Tab to move the cursor to the Cancel button and then press to cancel the operation 27 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application 3 3 Selecting an Item When the main screen is displayed press the function key F6 below Setup to open the System Setup window The cursor is on Work Mode Press to open the Work Mode Setup window Work Mode Setup Real time Sample Triggered Sample Periodic Sample Single Lead 6 channels Three Leads 12 channels Cancel 1 Press Tab or Shift Tab to move
31. if you press the START STOP key to print an ECG report in the auto quick mode or the manual mode the recorder will not respond 3 The electrocardiograph can not print ECG reports when transmitting data through USB socket 2 8 1 Auto Mode Operation Method 1 To set Mode Options Auto DispStyle Sampling Mode Preview Record Style Rhythm Lead1 2 3 or Lead Sequence Optional When the main screen is displayed press the function key F6 below Setup to open the System Setup screen The cursor is on Work Mode Press to open the Work Mode Setup window 1 Press Tab or Shift Tab to move the cursor to AUTO press Spacebar to select it and then a check mark V appears in the box before AUTO 2 Press Tab or Shift Tab to move the cursor to the Auto DispStyle list box and then press the Up or Down arrow to highlight a style 66 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 3 Press Tab or Shift Tab to move the cursor to the Sampling Mode list box and then press the Up or Down arrow to highlight a sampling mode For details of the sampling mode refer to Section 11 1 5 Selecting Sampling Mode 4 Press Tab or Shift Tab to move the cursor to Preview and then press the Up or Down arrow to highlight Off or On 5 Press esa or press Tab or Shift Tab to move the cursor to the OK button and then press EE Work Mode Setup Periodic Sample 60 C 6 channels Three Lea
32. is displayed press the MODE key to select the auto mode Press F3 to select a paper speed Press F4 to switch the gain Press F5 to set the EMG filter or the Lowpass filter 3 Press the START STOP key to print an ECG report It will stop automatically after printing a complete ECG report of 12 leads Or press the START STOP key again to stop printing the report 4 If Preview is set to On in the Work Mode Setup window press the START STOP key to display the preview screen 00i Marry Johnson Template Figure 8 1 Waveform Preview Screen 69 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 1 Press the function key F1 below Waveform to display the Waveform Preview Screen 2 Press the function key F2 below Template to display the template preview screen 3 Press the function key F3 below Measure to display the measure preview screen 4 Press the function key F4 below Diagnosis to open the diagnosis preview screen 5 Press the function key F5 below Continue to print an ECG report 6 Press the function key F6 below Cancel to stop printing the ECG report 8 2 Manual Mode Operation Method 1 To set Mode Options Manual Style or Lead Sequence Optional When the main screen is displayed press the function key F6 below Setup to open the System Setup screen The cursor is on Work Mode Press to open the Work Mode Setup window 1 Press Tab or Shift Tab to move the cursor to MANU press Sp
33. of a damage caused by mishandling during shipping b subsequent damage caused by improper use or maintenance c damage caused by alteration or repair by anyone not authorized by EDAN d damage caused by accidents e replacement or removal of serial number label and manufacture label If a product covered by this warranty is determined to be defective because of defective materials components or workmanship and the warranty claim is made within the warranty period EDAN will at its discretion repair or replace the defective part s free of charge EDAN will not provide a substitute product for use when the defective product is being repaired 17 2 Contact information If you have any question about maintenance technical specifications or malfunctions of devices contact your local distributor Alternatively you can send an email to EDAN service department at support edan com cn 186 SE 12 Series Electrocardiograph User Manual Technical Specifications Appendix 1 Technical Specifications A1 1 Safety Specifications Comply with IEC EN 60601 1 A1 A2 IEC EN 60601 1 2 A1 IEC EN 60601 2 25 ANSI AAMI EC11 IEC EN 60601 2 51 UL 60601 1 CAN CSA C22 2 No 601 1 Anti electric shock type Class I with internal power supply Anti electric shock degree CF type with defibrillation proof Degree of protection against harmful ingress of water Ordinary equipment Sealed equipment without liquid p
34. of the patient ID is 0 1999 999 999 2 Or the system can generate the patient ID according to the time when you press the START STOP key to print an ECG report The procedures are as follows 1 Press the function key F6 below Setup to open the System Setup screen 2 Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Patient Info press E 3 Press Tab or Shift Tab to move the cursor to ID Mode and then press the Up or Down arrow to select Time 4 Press PSs or press Tab or Shift Tab to move the cursor to the OK button and then press T 5 Press ESC to return to the main screen Then the system will generate the patient ID according to the time when you press the START STOP key to print an ECG report 3 Or you can enter the patient ID manually The procedures are as follows 1 Press the function key F6 below Setup to open the System Setup screen 2 Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Patient Info press a s57 SE 12 Series Electrocardiograph User Manual Entering Patient Information 3 Press Tab or Shift Tab to move the cursor to ID Mode and then press the Up or Down arrow to select Manual 4 Press CA or press Tab or Shift Tab to move the cursor to the OK button and then press 5 Press ESC to return to the main screen 6 Press the function key F1 below Patient to op
35. textbox appears and the Age textbox becomes unavailable in the Patient Information window you can enter the birthday of the patient and the system will calculate the patient age automatically 6 3 Using a Bar Code Reader 1 Configure the bar code 1 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen 2 Press F1 to display the Service Password window Then enter the password and press to open the Advanced Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to Barcode and then press to open the Barcode Setup window Advanced Setup 60 SE 12 Series Electrocardiograph User Manual Entering Patient Information Barcode Setup Cancel 3 Enter the start and end addresses the male and female codes the vendor ID and the product ID and then press to confirm View the vendor ID and product ID on the PC a Connect the bar code reader to the PC b Click on start right click on My Computer and then select Manage in the pop up menu to open the Computer Management window w Paint KA PC ECG fa Notepad Open Explore Search Defaults Map Network Drive amp Printers and Faxes Disconnect Network Drive x3 MSN Helb and t Show on Desktop e ree Rename 3 Windows Messenger Search Properties 7 Run All Programs gt 2 Log Off fo
36. the cursor to R R press Spacebar to select it and then a check mark V appears in the box before R R 2 Press Tab or Shift Tab to move the cursor to the Rhythm Style list box Press the Up or Down arrow to highlight Single Lead or Three Leads 3 Press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm 4 Press ESC to cancel the operation or press Tab or Shift Tab to move the cursor to the Cancel button and then press to cancel the operation 28 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application 3 4 About the main screen After you turn on the device the main screen pops up C XD F G H AUTO 60 12 00 01 Sampling p01 Mar ry P o h nson o i M _ aml j j E E oe P j A n See icin cine Figure 3 2 SE 12 Main Screen 29 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Name Explanation Patient Name within 60 ASCII characters or the equivalent Name number of other characters that can be supported by equivalent memory used by 60 ASCII characters When ID Mode is set to Manual the patient ID is within 30 ASCII characters ID When ID Mode is set to Auto the patient ID is 0 1999 999 999 When ID Mode is set to Time the patient ID is within 10 characters Patient Age Age The patient age value and the age unit can
37. to On and External Output is set to Standard or Triggered the electrocardiograph sends the signals which it receives If External Input is set to Off and External Output is set to Standard the electrocardiograph sends ECG signals of rhythm lead I If External Input is set to Off and External Output is set to Triggered the electrocardiograph sends pulses with the height of 4V and the width of 40ms based on the data of rhythm lead I 154 SE 12 Series Electrocardiograph User Manual System Setup 11 11 6 Setting Pacemaker Detection Sensitivity Press Tab or Shift Tab to move the cursor to Pacemaker Detection Sens on the Other Setup Window and then press the Up or Down arrow to highlight Low or High When Pacemaker Detection Sens is set to High the pacemaker signals are easy to be detected When Pacemaker Detection Sens is set to Low the pacemaker signals are not easy to be detected For more information about the detectable parameter ranges please refer to Appendix 1 Technical Specifications NOTE If you select Pacemaker in the Patient Information Setup window the pacemaker sensitivity can only be set in the Patient Information window and the setting of Pacemaker Detection Sens on the Other Setup Window is ineffective 155 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional Chapter 12 Operation Instructions for Exercise ECG Configurable for SE 12 Expr
38. using the method described in AAMI EC11 3 2 7 1 Overall System Error is not more than 5 3 Frequency Response is tested using the method described in AAMI EC11 3 2 7 2 methods A and D 190 SE 12 Series Electrocardiograph User Manual EMC Information Appendix 2 EMC Information Guidance and manufacture s declaration electromagnetic emissions for all EQUIPMENT and SYSTEMS Guidance and manufacture s declaration electromagnetic emission that it is used in such an environment The 12 channel electrocardiograph is intended for use in the electromagnetic environment specified below The customer or the user of the 12 channel electrocardiograph should assure IEC EN 61000 3 3 Emission test Compliance Electromagnetic environment guidance The 12 channel electrocardiograph uses RF 0 energy only for its internal function RF emissions De A Group 1 Therefore its RF emissions are very low and CISPR 11 are not likely to cause any interference in nearby electronic equipment RF emission Class A CISPR 11 Harmonic eimissions The 12 channel electrocardiograph is suitable Class A for use in all establishments other than IEC EN 61000 3 2 domestic and those directly connected to the Voltage public low voltage power supply network that fuct ationsi thicket supplies buildings used for domestic purposes emissions Complies 191 SE 12 Series Electrocardiograph User Manual EMC Inf
39. 10 Timer 82 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 60 Heart Rate Tl 1mV calibration mark II V1 V5 Rhythm Lead Name 20s rhythm waveform of lead II V1 V5 0 67 100Hz 0 67Hz DFT Filter 100Hz Lowpass Filter ACS50 50Hz AC Filter 25mm s Paper Speed 10mm mV Gain Institution Name SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm Version Number 8 6 3 ECG Reports in the Manual Mode 02 06 2010 16 56 30 98595 ID 001 Age 25 Years Name Marry Johnson PN i V6 Ea 0 67 100Hz ACSO 25mmis 10mm mV C60 Institution Name SE 12Express V1 8 SEMIP V1 5 The above figure shows an ECG report in the manual mode and Manual Style is set to 12 channels 02 06 2010 16 56 30 Current Date amp Current Time ID 001 Patient ID Age 25 Years Patient Age Name Marry Johnson Patient Name 83 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Tl 1mV calibration mark I I IW aVR aVL aVF V1 V2 V3 V4 V5 V6 12 standard leads ECG waveform of 12 standard leads 0 67 100Hz 0 67Hz DFT Filter 100Hz Lowpass Filter ACS50 50Hz AC Filter 25mm s Paper Speed 10mm mV Gain 760 Heart Rate Institution Name SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm Version Number 8 6 4 ECG Reports in the R R Analysis Mode OANE 30 06 2010 17 43 18 98057
40. 117 6 Setting IRS VoMune es mca once jaa etviiesnien mania Ea r E A 138 11 8 Date se Time Setups sini etw eatin ahaa le ee ara eee eae 138 Teel Sette Dat and TiNe censi ltrs pecs td pl alas de oat cea ala Let 139 L182 Settine Date Modernne ne ocdec vases e R onto eahc gait aes ae awe 139 113 3 Setting ime Mode 23 5 deseo iscid a asatacase daar euned Maire a aks Saas Gig Ake is 140 11 8 4 Setting Power Off T tiie as Beaccap sues shuts cancareede cadesaeagitaeactouaty nec ca od eecdusaeadiee de leosacnganes 140 118 S Sete LODO TIME sanr os ceceen ys tdeaies eines e Maa decken sa a oacce Mot ecis eases ves 140 tO File Setipinna e transite kesh aig E E disancth E A A 140 TL91 Selecting Auto SAN Casas eas niana aa E A AE A Ra a SE 141 LOD Setting Saving Pathissgscecenanini rni an R E A T mech ae kee 141 LAOS Sette File Formatar rgesiron onn Sok Crone E E stat ih 142 11 9 4 Selecting Deleting Files After Transmission or Expott sssssessessssssessessrssressesssesees 142 11 9 5 Selecting Replacing When Memory is Full 0 cecceeccesseeeseeeseceeeceeeceeseeesseenteenaes 142 11 9 6 Selecting SCP File Compressions cs cccsesceaectissed Ais tas tedind Meee iee dena As ae tans tans 142 11 10 System Maintenance Seuips c cc 7tcatsac castujacc are sehcatusiecteecceucay jaca ie teuatigucdendeaccealenaee 143 11 10 1 Exporting System Settings to UDISk ceases socacecisisleaskee ceases sndcedeciieacecsieaxcbesduuans ads 143 11 10 2 Loading System Settings
41. 3 ID gt 001 Measuring Time 180 s Name Marry Johnson Total Beat Number 240 Age 2 25 Years Gender Female HR 80 BPM Height 165 cm Weight 50 kg Room No 0023 RRAvginterval 749 ms RRMaxinterval 866 ms RRMininterval 633 ms Max Min 1 368 SDNN 2 208ms RMSSD 10 976 Report Confirmed by s RR Trend 2 0 RR Histogram 100 1 8 1 6 80 1 4 2 60 ie 1 0 il it aranana nT SAT FATT AENT 0 6 24 i 0 4 0 i as 0 2 0 2 0 4 0 6 0 8 1 0 2 i4 1 6 1 8 0 o t 2 3 s min institution Name SE 12 EXPRESS V18 SEMIP V1 5 a 84 Printing ECG Reports SE 12 Series Electrocardiograph User Manual oS eS au aie E ze eens 85 SE 12 Series Electrocardiograph User Manual Printing ECG Reports FST noA 3724S BR Se oie Sh CR pp ua vran ites CN ay ID 001 Age 25 Years Name Marry Johnson RR _ Interval List ms No No No No No No 1 633 44 750 87 750 130 866 173 634 216 750 2 866 45 634 88 750 131 750 174 866 217 634 3 750 46 866 89 634 132 750 175 750 218 866 4 750 47 750 90 866 133 634 176 750 219 750 634 48 750 91 750 134 866 177 634 220 750 6 866 49 634 92 750 135 750 178 866 221 634 7 750 50 866 93 634 136 750 179 750 222 866 8 750 51 750 94 866 137 634 180 750 223 750 9 634 52 750 95 750 138 866 181 634 224 750 10 866 53 634 96 750 139 750 182 866 225 634 11 750 54 866 97 634 140 750 183 750 226 866 12 750 55 750 98 866 1
42. 41 634 184 750 227 750 13 634 56 750 99 750 142 866 185 634 228 750 14 866 57 634 100 750 143 750 186 866 229 634 15 750 58 866 101 634 144 750 187 750 230 866 16 750 59 750 102 866 145 634 188 750 231 750 17 634 60 750 103 750 146 866 189 634 232 750 18 866 61 634 104 750 147 750 190 866 233 634 19 750 62 866 105 634 148 750 191 750 234 866 20 750 63 750 106 866 149 634 192 750 235 750 21 634 64 750 107 750 150 866 193 634 236 750 22 866 65 634 108 750 151 750 194 866 237 634 2750 66 866 109 634 152 750 195 750 238 866 2750 67 750 110 866 153 634 196 750 239 750 2634 68 750 111 750 154 866 197 634 7866 69 634 112 750 155 750 198 866 2750 70 866 113 634 156 750 199 750 28 750 71 750 114 866 157 634 200 750 29 634 72 750 115 750 158 866 201 634 30 866 73 634 116 750 159 750 202 866 31 750 74 866 117 634 160 750 203 750 32 750 75 750 118 866 161 634 204 750 33 634 76 750 119 750 162 866 205 634 34 866 77 634 120 750 163 750 206 866 35 750 78 866 121 634 164 750 207 750 36 750 79 750 122 866 165 634 208 750 37 634 80 750 123 750 166 866 209 634 38 866 81 634 124 750 167 750 210 866 39 750 82 866 125 634 168 750 211 750 40 750 83 750 126 866 169 634 212 750 41 634 84 750 127 750 170 866 213 634 42 866 85 634 128 750 171 750 214 866 43 750 86 866 129 634 72 750 215 750 i Institution Name SE 12 EXPRESS V1 8 SEMIP V1 5 NNN Nh IAn ew c The above figure a b and c show an
43. ATA ECG X Export Examination Date and Time of the U disk 108 SE 12 Series Electrocardiograph User Manual Managing Files If the U disk is not connected well the hint U disk is not ready will be displayed on the LCD screen of the electrocardiograph and then you should connect the U disk again If the electrocardiograph fails to export files the hint Exporting fails will pop up After the electrocardiograph successfully exports files the hint Exporting succeeds will be displayed NOTE 1 Please insert the U disk or the SD card reader recommended by the manufacturer Please set the format to FAT or FAT32 when formatting the U disk 2 The format of the exported files can be set to DAT SCP FDA XML PDF For details refer to Section 9 2 Exporting ECG Data to the U Disk Automatically 3 X can be set in the Device No textbox in the Transmission Setup window 4 If you select Delete After Trans Or Export in the File Setup window the files will be deleted from the File Manager screen after they are exported 10 3 Deleting Files 1 When the main screen is displayed press the function key F7 below File to open the File Manager screen 2 Press the function key F3 below Del All to display the following hint press Tab or Shift Tab to move the cursor to the OK button and then press to delete all the files from the electrocardiograph HINT You will delete all files sure Cancel 3 Or press the Up
44. C4 White Brown V4 Brown Blue C5 White Black V5 Brown Orange C6 White Violet V6 Brown Violet 53 SE 12 Series Electrocardiograph User Manual Operation Preparations The Precordial Electrodes Positions on Body Surface C1 Fourth intercostal space at the right border of the sternum C2 Fourth intercostal space at the left border of the sternum C3 Fifth rib between C2 and C4 C4 Fifth intercostal space on the left midclavicular line C5 Left anterior axillary line at the horizontal level of C4 C6 Left midaxillary line at the horizontal level of C4 The Extremity Electrodes Positions on Body Surface R L below the right left clavicle N F below the right left rib The quality of ECG waveform will be affected by the contact resistance between the patient and the electrode In order to get a high quality ECG the skin electrode resistance must be minimized while connecting electrodes Electrodes Connection 1 Align all lead wires of the patient cable to avoid twisting and connect the disposable electrodes to the lead wires 2 Clean the electrode areas on the body surface with 75 alcohol 3 Attach the disposable electrodes to the electrode sites NOTE The quality and the placement of the electrode will directly influence the quality of exercise ECG The wrong placement and use of electrodes will cause incorrect analysis results WARNING 1 Make sure that all electrodes are connected to the patient correctly
45. CG Data in SCP FDA XML PDF Format Through Net Cable 142 SE 12 Series Electrocardiograph User Manual System Setup 11 10 System Maintenance Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Maintenance on the System Setup screen press to open the System Maintenance window System Maintenance Export Settings To U disk Load Settings From U disk Back up Settings Load Backup Settings Record System Settings Load Factory Settings Press lt Tab gt or lt Shift Tab gt to move the cursor Figure 11 12 System Maintenance window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 10 1 Exporting System Settings to U Disk 1 Connect a U disk to the electrocardiograph 2 Press Tab or Shift Tab to move the cursor to the Export Settings To U disk button in the System Maintenance window and then press to export the system settings to the U disk 143 SE 12 Series Electrocardiograph User Manual System Setup 11 10 2 Loading System Settings from U Disk 1 Connect the U disk containing the system settings to the electrocardiograph 2 Press Tab or Shift Tab to move the cursor to the Load Settings From U disk button in the System Maintenance window and then press to load the system settings from the U disk to the electrocardiograph
46. Electrocardiograph User Manual Transmitting ECG Data Automatically 3 Log into the FTP receiving software The FTP port is 21 4 In the auto or rhythm mode ECG data will be transmitted through the net cable automatically after an ECG report is printed out In the off mode ECG data will be transmitted through the net cable automatically after the START STOP key is pressed 9 2 Exporting ECG Data to the U Disk Automatically 1 Insert the U disk recommended by the manufacturer to USB socket 2 of the electrocardiograph 2 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to File press to open the File Setup window 3 Press Tab or Shift Tab to move the cursor to the Auto Save list box and then press the Up or Down arrow to select On Press Tab or Shift Tab to move the cursor to the Saving Path list box and then press the Up or Down arrow to select U Disk Press Tab or Shift Tab to move the cursor to File Format and then press the Up or Down arrow to select DAT SCP FDA XML PDF For details on activating SCP FDA XML PDF function on the Advanced Setup screen refer to Section 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format Through Net Cable Auto Save Saving Path E ie File Format Del After Trans Or Export DAT 7 off 7 Auto Replace When MEM Full off x Press Gea or press T
47. F N RL NOTE The left side of is European standard and the right side is American standard 2 Serial Port 1 should not exceed 15V DC Definitions of corresponding pins WARNING The isolated intensity of serial port 1 is 1500V AC and the maximum voltage applied Pin Signal Pin Signal Pin Signal 1 NC 4 NC 7 NC 2 RxD input 5 GND NC 3 TxD output 6 NC 9 NC 3 Serial Port 2 20 SE 12 Series Electrocardiograph User Manual Definitions of corresponding pins About the Electrocardiograph Application Pin Signal Pin Signal 1 TxD output 5 NC 2 RxD input 6 NC 3 NC 7 GND 4 NC 8 GND 4 External Input Output Socket TR 4 s o e Definitions of corresponding pins Pin Signal Pin Signal 1 GND 4 GND 2 GND 5 ECG Signal input 3 GND 6 ECG Signal output 5 USB Socket 1 USB Socket 2 Optional Only the USB equipment recommended by the manufacturer can be connected to the USB interface CAUTION 21 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Definitions of corresponding pins Pin Signal Pin Signal 1 5V 3 D 2 D 4 GND WARNING 1 Accessory equipment connected to the analog and digital interfaces must be certified according to the respective IEC EN standards e g IEC EN 60950 for data processi
48. Filter list box in the Filter Setup window Press the Up or Down arrow to highlight an option 120 SE 12 Series Electrocardiograph User Manual System Setup DFT Filter greatly reduces the baseline fluctuations without affecting the ECG signals The purpose of this filter is to keep the ECG signals on the baseline of the printout The set value is the low limit of the frequency range including 0 05Hz 0 15Hz 0 25Hz 0 32Hz 0 5Hz and 0 67Hz 11 2 3 Setting EMG Filter Press Tab or Shift Tab to move the cursor to the EMG Filter list box in the Filter Setup window Press the Up or Down arrow to highlight an option EMG Filter suppresses disturbance caused by strong muscle tremor The cutoff frequency can be set to 25Hz 35Hz or 45Hz Select Off to turn off the function 11 2 4 Setting Lowpass Filter Press Tab or Shift Tab to move the cursor to the Lowpass Filter list box Press the Up or Down arrow to highlight an option Lowpass Filter restricts the bandwidth of input signals The cutoff frequency can be set to 150Hz 100Hz or 75Hz All the input signals whose frequency is higher than the set cutoff frequency will be attenuated NOTE 1 Only when EMG Filter is set to Off can the setting of Lowpass Filter be effective 2 To the patient with a pacemaker the EMG filter should be set to Off and the Lowpass filter should be set to 150Hz or else the amplitude of the pulses may decrease the width may increase and the
49. ING The performance and electric shock protection can be guaranteed only if the original patient cable and electrodes of the manufacturer are used The patient cable includes the main cable and lead wires which can be connected to electrodes A Lead Wires N Vy Connecting to Electrocardiograph Main Cable Connecting to Electrodes Patient Cable for Resting ECG Main Cable Lead Wires Screw Electrode Connector Connecting to the ECG Sampling Box Patient Cable for Exercise ECG 47 SE 12 Series Electrocardiograph User Manual Operation Preparations 1 Connecting the Patient Cable to the Electrocardiograph Connect the patient cable to the patient cable socket on the right side of the main unit and then secure them with two screws 2 Connecting the Patient Cable to Electrodes Align all lead wires of the patient cable to avoid twisting and connect the lead wires to the reusable electrodes or the alligator clips Firmly attach them 4 5 Attaching Electrodes to the Patient for Resting ECG 4 5 1 Lead Placement 4 5 1 1 Standard 12 Lead Placement The identifiers and color codes of electrode connectors used comply with IEC EN requirements In order to avoid incorrect connection the identifiers and color codes are specified in Table 4 1 Moreover the equivalent codes according to European requirements are given in Table 4 1 too Table 4 1 Electrode Connectors and Their Identifiers and Color
50. Language on the Other Setup Window and then press the Up or Down arrow to highlight a language 153 SE 12 Series Electrocardiograph User Manual System Setup 11 11 3 Selecting Caps Lock Press Tab or Shift Tab to move the cursor to Caps Lock on the Other Setup Window and then press the Up or Down arrow to highlight Off or On When Caps Lock is set to On the letters entered will be capital Pressing Shift Le and a letter key can input a lowercase letter When Caps Lock is set to Off the letters entered will be lowercase Pressing Shift o and a letter key can input a capital letter 11 11 4 Setting External Input Press Tab or Shift Tab to move the cursor to the External Input list box on the Other Setup Window and then press the Up or Down arrow to highlight Off or On The extern input socket is equipped in the electrocardiograph through which the electrocardiograph can receive signals from the external equipment NOTE When External Input is set to On the touch screen becomes ineffective and then you should operate the device by using the keyboard 11 11 5 Setting External Output Press Tab or Shift Tab to move the cursor to the External Output list box on the Other Setup Window and then press the Up or Down arrow to highlight an option The extern output socket is equipped in the electrocardiograph through which the electrocardiograph can send signals to the external equipment If External Input is set
51. Li ion Battery Pack rare ca arts SE 12 Rated voltage 14 8V SE 12 Express Rated capacity 4400mAh SE 12 Rated capacity 2200mAh When the battery is fully charged SE 12 can work normally about 4 hours and it can continually print about 1 5 hours in the manual mode or print about 300 ECG reports of 3x4 1R in the auto mode SE 12 Express can work normally about 5 hours and it can continually print about 2 5 hours in the manual mode or print about 350 ECG reports of 3x4 1R in the auto mode Charge mode Constant current voltage SE 12 Express Charge current standard 0 14 CsA 600mA SE 12 Charge current standard 0 28 CsA 600mA Charge voltage standard 16 8 0 1V Necessary Charge time SE 12 Express 9 5 hours SE 12 5 hours 188 SE 12 Series Electrocardiograph User Manual Technical Specifications Cycle life gt 300 times Fuse TLAL250VP 5x20 A1 5 Performance Specifications Recording Recorder Thermal dot matrix recorder Printing Density 8 dots per mm 200 dots per inch amplitude axes 40 dots per mm 1000 dots per inch time axes 25 mm s Recorder Paper Folded thermal paper 210mmx295mm 100pages Folded thermal paper 215mmx280mm 100pages Optional Rolled thermal paper 210mmx30m Optional Effective Width 203mm Paper Speed 5mm s 6 25mm s 10mm s 12 5mm s 25mm s 50mm s 43 Accu
52. NOTE 1 To transmit ECG data in DAT format to the PC the Smart ECG Viewer software of the manufacturer must be installed in the PC You should log into the Smart ECG Viewer software before transmission 2 To transmit ECG data in SCP FDA XML PDF format to the PC the FTP receiving software must be installed in the PC You should log into the FTP receiving software before transmission Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Transmission on the System Setup screen press to open the Transmission Setup window 131 SE 12 Series Electrocardiograph User Manual System Setup Transmission Setup 192 F168 do go 4255 F255 f255 fo OK Figure 11 7 Transmission Setup window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 5 1 Setting Device No Press Tab or Shift Tab to move the cursor to the Device No textbox and then fill in the textbox If you input 1 in the Device No textbox after you save data to the U disk the data will be in the directory of ECGDATA ECG 01 Store Examination Date of the U disk after you export files from the electrocardiograph to the U disk the files will be in the directory of ECGDATA ECG 01 Export Examination Date and Time of the U disk after you import files from the U disk to
53. P Monitor Press Tab or Shift Tab to move the cursor to the Device Type list box and then press the Up or Down arrow to highlight Treadmill or Ergometer Press Tab or Shift Tab to move the cursor to the Device Model list box and then press the Up or Down arrow to specify the device model Press Tab or Shift Tab to move the cursor to the BP Monitor list box and then press the Up or Down arrow to highlight Off Tango or In Ergometer 160 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional General Information Setup xd AxS Treadmill Off C ODF Cancel 5 Press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 6 Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Protocol on the System Setup screen press to open the Protocol Manager screen Select a protocol by pressing the Up or Down arrow Then press the function key F7 below Return to return to the System Setup screen 161 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional Protocol Manager No Protocol Name Default 1 v eie Seet Delete De AI Restore Return 7 Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to Return and then press to return to the main screen of the e
54. Preparations American European id tabi Electrode Placement Al Net Attachment point of the second rib to the right sternal edge A2 Nax Fifth intercostal space on the left posterior axillary line V4 Nap Left mid clavicular line in the fifth intercostal space RA R Right arm LA L Left arm RL NorRF Right leg LL F Left leg 4 5 2 Electrode Placement Two kinds of electrode can be used one is the reusable electrode and the other is the disposable electrode 4 5 2 1 Reusable Electrodes Reusable electrodes include limb electrodes and chest electrodes as the following figures show Suction Bulb Metal Cup oS Connecting to a Lead Wire Chest Electrode 50 SE 12 Series Electrocardiograph User Manual Operation Preparations Connecting to a Lead Wire Reed Clamp Limb Electrode Chest Electrode Connection 1 2 3 4 5 6 7 Ensure that the electrodes are clean Align all lead wires of the patient cable to avoid twisting and connect the lead wires to the corresponding electrodes according to the colors and identifiers Clean the electrode area on the chest surface with 75 alcohol Daub the round area of 25mm in diameter on each electrode site with gel evenly Place a small amount of gel on the brim of the chest electrode s metal cup Place the electrode on the chest electrode site and squeeze the suction bulb Unclench it and the electrode is adsorbed on the chest Attach al
55. RS232 socket of the electrocardiograph with an RS232 cable 2 Or if the PC has no RS232 socket connect the USB socket of the PC to the RS232 socket of the electrocardiograph by using the RS232 USB assembly For details of the RS232 USB assembly please refer to Section 9 1 1 Transmitting ECG Data in DAT Format Through Serial Cable 3 Log into the Smart ECG Viewer software NOTE If you don t connect the RS232 socket of the electrocardiograph to the PC or you do not log into Smart ECG Viewer before transmission the following hint will pop up HINT Please check UART cable connection and PC software 4 Set Transmission Mode to UART in the Transmission Setup window For details refer to Section 9 1 1 Transmitting ECG Data in DAT Format Through Serial Cable 5 Press the function key F7 below File to display the File Manager screen 6 Press the function key F1 below Trans All to transmit all the files to the PC After all the files are transmitted the following hint will pop up HINT Transmitting succeeds 7 Or press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Press the function key F3 below Trans to transmit the selected file to the PC 105 SE 12 Series Electrocardiograph User Manual Managing Files 10 1 2 Transmitting DAT Files through Net Cable 1 Co
56. Rhythm Lead 1 II 50 Rhythm Lead 2 Vi 51 Rhythm Lead 3 V5 59 Screen Colors Only for SE 12 Option 1 Express 53 Antialiasing Off 54 QRS Volume Off 55 Hint Volume Medium 56 Key Volume Medium 57 Date Mode DD MM YYYY 58 Time Mode 24 Hours 59 Power Off 0 SE 12 Series Electrocardiograph User Manual System Setup 60 LCD Off 0 61 Auto Save On 62 Saving Path ECG 63 File Format PDF 64 Delete After Trans Or Export Off 65 Replace When Memory Full Off 66 SCP File Compression On 67 System Password Cleared 68 Caps Lock Off 69 Pacemaker Detection Sensitivity Low Exercise ECG 1 Display Style 6x2 2 Speed Unit mph 3 Post J 60ms 4 Device Type Treadmill 5 Device Model TMX425 6 Ergometer Ergoline 7 BP Monitor In Ergometer 8 Maximum Systole 220mmHg 9 Maximum Diastole 90 mmHg 10 Minimum Systole 110 mmHg 11 Minimum Diastole 60 mmHg 12 Max Predicted HR 220 13 The proportion of Target HR in Max 85 Predicted HR 14 AC Filter On 15 DFT Filter 0 67Hz 16 EMG Filter Off 17 Lowpass Filter 100Hz 151 SE 12 Series Electrocardiograph User Manual System Setup 18 Rhythm Lead 1 II 19 Rhythm Lead 2 Vi 20 Rhythm Lead 3 V5 21 Lead Sequence Standard 22 Gain 10mm mV 23 Paper Marker Yes 24 Exercise Report Late Stage 25 Report Style 3x4 1 26 Recovery Report On 27 Start time of Recovery Report 10
57. Right Panel 18 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application G A B E F Figure 2 10 SE 12 Right Panel Name Explanation A Patient Cable Socket Connecting to the patient cable Connecting to a PC B Serial Port 1 In the exercise test only the treadmill ergometer recommended by the manufacturer can be connected C USB Socket 1 Optional Standard USB socket connecting to a PC Standard USB socket connecting to a U disk a D USB Socket 2 Optional bar code reader or a USB printer recommended by the manufacturer E External Input Output Socket Connecting to the external signal device In the exercise test only the BP Monitor F Serial Port 2 recommended by the manufacturer can be connected G Net port Standard net port connecting to a PC 1 Patient Cable Socket 8 7 6 5 4 3 2 1 TI J L 2 mn P P P EA 15l14l13l12l 11 101 9 ilo Applied part of type CF with defibrillator proof A Caution 19 SE 12 Series Electrocardiograph User Manual Definitions of corresponding pins About the Electrocardiograph Application Pin Signal Pin Signal Pin Signal 1 C2 V2 6 SH 11 F LL 2 C3 V3 7 NC 12 a or NC 3 C4 V4 8 NC 13 C1 V1 4 C5 V5 9 R RA 14 REINIE or NC 5 C6 V6 10 L LA 15 R
58. Save the selected RS232 protocol or restore the default RS232 protocol which is also the LODE PROTOCOL Turn off the ergometer gt For controlling the ergometer by SE 12 Express the ergometer should be set in the ANALOG mode The ANALOG mode should be selected as follows After turning on the ergometer press Enter select ANALOG and press Enter again NOTE You can also let the ergometer start up in the ANALOG mode every time you turn on the ergometer by using the default start menu To set the ergometer for starting up in the ANALOG mode proceed as follows e Turn on the ergometer and press Enter e You will be in MAINMENU e Select by using the Up Down keys the menu SYSTEM PARAMETER and press Enter e Select by using the Up Down keys the menu SETTINGS and press Enter e Press Enter to confirm the menu DEFAULTSTARTMENU and press Enter 163 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional If you turn off the ergometer it will start up in the ANALOG mode every time the ergometer is turned on again gt The Lode ergometer is now ready for external control For details on setting other models for external control please refer to the connection instruction of the models 9 When the main screen of the exercise test is displayed press the function key F1 below Patient to open the Patient Information window Enter the patient information For details on entering patient in
59. Transmission press to open the Transmission Setup window 3 Press Tab or Shift Tab to move the cursor to the Auto Transmission list box and then press the Up or Down arrow to select On Press Tab or Shift Tab to move the cursor to the Transmission Mode list box and then press the Up or Down arrow to select UART 4 Press ESB or press Tab or Shift Tab to move the cursor to the OK button and then press ES 5 Press ESC to return to the main screen 4 Log into the Smart ECG Viewer software 93 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Automatically 5 In the auto or rhythm mode ECG data will be transmitted through the serial cable automatically after an ECG report is printed out In the off mode ECG data will be transmitted through the serial cable automatically after the START STOP key is pressed 9 1 2 Transmitting ECG Data in DAT Format through Net Cable 1 Connect the electrocardiograph to the network of the PC with an Ethernet cable recommended by the manufacturer If the wireless AP transmission is used connect the PC to the server wireless AP and connect the electrocardiograph to the client wireless AP Only the wireless AP recommended by the manufacturer can be used NOTE 1 For details on configuring the wireless AP please refer to the user manual delivered with the wireless AP 2 There should be no shield in or around the room where the wireless AP is used
60. a tons scienee 5 1 2 4 Preparation and Operation Warnings for SE 12 Express Exercise ECG ceeeeee 6 1 2 6 Contraindications for SE 12 Express Exercise ECG ccccssccsssscseccssccesncssensessceesees 7 LS Listof Symbols 35 3 ccs cicsiak a E E neler aaa taeda etre ae eae Alon 8 Chapter 2 Tintro dct ints eviscs vssscsveyeveseseesvsssnesscennssoncssiencovesavavevestcsuduocvavessesnsegenesenveesssseessceniececoers 11 PM VO Panele hoc Saac wala Set atasite vances ath oases cu toee A vu ates eaueas eset ete N 12 2 2 Keyb ard and RC VG ct atts cach ds cts arag anii a n e as areas a a 13 DSTO Panel aee a a dendts Waa aeeeau res EE yu see sane oaece au icles cau Beasinces Seve A as eee ea ee 16 2 4 Rear Panelini ni a in ciel a e a fesaa mda dps dceal 17 Di Right Panelo api oeenn ai aiia rena aTe AEE ae A E RE KATTE EAER EA TESA REAA ATO EENS 18 DO B ttom Pah baseetan E Seg oa E R teats 22 2 7 Function FeatUrEs oniinn a e n E R ARR Re S 24 Chapter 3 About the Electrocardiograph Application esssesssessssesssecesocesocesooesssecssocesocssooseso 26 Del SSIS CHINO Menu FUNCTIONS eii e ina a a a e a a a A stews haces 26 Ded Bite NOD Ae ces ates ca tatus anes A T O E TT A a ictlta 27 3 3 Selectine a NCI 4 says sas aciseczateceyseyedast ina aeiigerahacabston a a a iaa aiani 28 SAA DOUL THE MIAMI SOCOM goer cikanie en a e a i a a a E A a S 29 3 5 About the main screen of Exercise ECG Optional for SE 12 Express ceeeeseeeeeeeee 31
61. ab or Shift Tab to move the cursor to the OK button and then press Ce When the System Setup screen is displayed press ESC to return to the main screen 99 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Automatically 4 In the auto or rhythm mode ECG data will be automatically exported to the directory of ECGDATA ECG X Store Examination Date of the U disk after an ECG report is printed out In the off mode ECG data will be automatically exported to the directory of ECGDATA ECG X Store Examination Date of the U disk after the START STOP key is pressed NOTE X can be set in the Device No textbox in the Transmission Setup window 9 3 Real time Transmission to PC ECG NOTE For the real time transmission the PC ECG software of the manufacturer must be installed in the PC 1 Run the PC ECG software and configure it for the real time transmission pa Double click on the shortcut icon 259 on the desktop to start up the PC ECG software Click on the System Setting button to open the System Setting window Click on the Device tab Select SE serial Machine from the Sampling Device pull down list on the device setup window After setup click on the OK button to confirm 100 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Automatically System Setting Basic Information Sample Setting evice printer Setting Others GDT Sampling Device Device Type Treadmill v Se serial Ma
62. ab to move the cursor to the Speed list box on the Setup 1 tab and then press the Up or Down arrow to highlight an option In the manual mode you can set Speed to 5mm s 6 25mm s 10mm s 12 5mm s 25mm s or 50mm s In the auto and rhythm modes only 25mm s and 50mm s are available In the R R analysis mode only 25mm s is available 11 3 1 7 Selecting Paper Marker Press Tab or Shift Tab to move the cursor to the Paper Marker list box on the Setup 1 tab and then press the Up or Down arrow to highlight No or Yes Paper Marker is used to identify the start point of each page of the recorder paper 125 SE 12 Series Electrocardiograph User Manual System Setup When the paper with black markers on the bottom is used and Paper Marker is set to Yes the device can identify the start point of each page of the recorder paper while printing ECG reports When Paper Marker is set to No the device can not identify the start point of each page of the recorder paper while printing ECG reports 11 3 1 8 Setting Sampling Time If Record Style is set to 12x1 you can set the time period Press Tab or Shift Tab to move the cursor to the Sample Time textbox and then input the time period manually If the time period is set from 11 to 24 seconds in the auto mode after pressing the START STOP key the ECG waves of the set time period are printed NOTE If the time period is set from 11 to 24 seconds the ECG data sampled will not be
63. acebar to select it and then a check mark V appears in the box before MANU 2 Press Tab or Shift Tab to move the cursor to the Manual Style list box and then press the Up or Down arrow to highlight a style 3 Press eee or press Tab or Shift Tab to move the cursor to the OK button and then press 70 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Work Mode Setup Real time Sample Triggered Sample Periodic Sample 60 Off a Three Leads 4 On the System Setup screen press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Lead press to open the Lead Setup window 5 Press Tab or Shift Tab to move the cursor to the Lead Sequence list box and then press the Up or Down arrow to select a sequence 6 Press Ce or press Tab or Shift Tab to move the cursor to the OK button and then press Ce Lead Setup Standard Cabrera After setup press ESC to return to the main screen 2914 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 2 When the main screen is displayed press the MODE key to select the manual mode Press F3 to select a paper speed Press F4 to switch the gain Press F5 to set the EMG filter or the Lowpass filter 3 Press the Up or Down arrow to select the lead group to be displayed and printed 4 Press the START STOP key to print an ECG report 5 Pres
64. ad Setup window and then press the Up or Down arrow to highlight Standard or Cabrera Lead Sequence Lead group 1 Lead group 2 Lead group 3 Lead group 4 Standard 1 I Wl aVR aVL aVF V1 V2 V3 V4 V5 V6 Cabrera aVL I aVR II aVF W V1 V2 V3 V4 V5 V6 11 6 3 Selecting Nehb Press Tab or Shift Tab to move the cursor to the Nehb list box in the Lead Setup window and then press the Up or Down arrow to highlight Off or On Lead Sequence I H HI ND NA NI NOTE If you set Nehb to On the working mode is fixed to be manual 11 7 Display amp Sound Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Display amp Sound on the System Setup screen press to open the Display amp Sound Setup window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 136 SE 12 Series Electrocardiograph User Manual System Setup Display amp Sound Setup Monochrome Option1 Option2 OK Cancel Figure 11 9 Display amp Sound Setup window 11 7 1 Setting Brightness Press Tab or Shift Tab to move the cursor to the Brightness progress bar in the Display amp Sound Setup window and then press the Left or Right arrow to adjust the brightness of the LCD screen You can set the brightness within 0 20 11 7 2 Selecting Display Colors O
65. and gt 95 dip in Ur gt 95 dip in Ur should be that of a typical voltage variations for 0 5 cycle for 0 5 cycle commercial or hospital on power supply environment If the user of input lines IEC EN 61000 4 11 40 Ur 60 dip in Ur for 5 cycles 70 Ur 40 Ur 60 dip in Ur for 5 cycles 70 Ur 192 the 12 channel electrocardiograph requires continued operation during power mains interruptions it is recommended that the SE 12 Series Electrocardiograph User Manual EMC Information 30 dip in Ur for 25 cycles lt 5 Ur gt 95 dip in Ur for 5 sec 30 dip in Ur 12 channel for 25 cycles electrocardiograph be powered from an lt 5 Ur uninterruptible power gt 95 dip in Ur supply or a battery for 5 sec NOTE Ur is the a c mains voltage prior to application of the test level Guidance and manufacture s declaration electromagnetic immunity for EQUIPMENT and SYSTEMS that are not LIFE SUPPORTING Guidance and manufacture s declaration electromagnetic immunity that it is used in such an environment The 12 channel electrocardiograph is intended for use in the electromagnetic environment specified below The customer or the user of the 12 channel electrocardiograph should assure Immunity IEC EN 60601 test Compliance Electromagnetic environment test level level guidance Portable and mobile RF communicati
66. apters 01 13 107449 Clip Snap Banana Socket Adapter 01 57 040172 Alligator Clip Banana Socket Adapters 01 57 040173 Paper Roller 01 51 30340 01 Thermal Recorder Paper 01 57 107371 Fuse 11 21 64073 184 SE 12 Series Electrocardiograph User Manual Accessories List Input Output Connector 11 13 19907 Grounding Wire 11 13 114214 Smart ECG Viewer Software ee 03 24 38953 Snap Clip 01 57 040172 Electrode Gel 11 25 78047 RS232 Cable 11 13 20117 Ethernet Cable 11 13 20096 Smart ECG viewer Software Key TINY SPRO 01 18 47116 Smart ECG viewer Software Key USB 12 01 47194 DeskJet HP2368 11 18 52168 U Disk 11 18 78105 ECG Bag 11 56 78118 SD Card Reader 11 17 047324 MT 801 Trolley 03 28 107634 12V Vehicle carried Inverter 11 21 64056 Bar Code Reader 11 23 068003 Wireless AP 11 17 047338 The 12 channel electrocardiograph and accessories are available by contacting the manufacturer or your local distributor NOTE The chest electrodes limb electrodes pediatric chest electrodes and pediatric limb electrodes are not available in the U S 185 SE 12 Series Electrocardiograph User Manual Warranty amp Service Chapter 17 Warranty amp Service 17 1 Warranty EDAN warrants that EDAN s products meet the labeled specifications of the products and will be free from defects in materials and workmanship that occur within warranty period The warranty is void in cases
67. arrow to highlight Sequential or Synchronous When Record Sequence is set to Sequential the lead group is printed one by one in a certain sequence The start time of a lead group is just the end time of the previous lead group 123 SE 12 Series Electrocardiograph User Manual System Setup When Record Sequence is set to Synchronous all leads are printed simultaneously The start time of each group is the same 11 3 1 4 Setting Gain Press Tab or Shift Tab to move the cursor to the Gain list box on the Setup 1 tab and then press the Up or Down arrow to highlight an option You can set the indicated height of ImV ECG on the paper You can set Gain to 10mm mV 20mm mV 10 5mm mV AGC 2 5mm mvV or 5mm mV AGC means auto gain control When ECG signals vary greatly AGC can be selected to adjust the gain automatically according to actual signals 10 Smm mV means that the gain of limb leads is set to 10mm mV while the gain of chest leads is set to 5mm mV 11 3 1 5 Selecting Recording Device Press Tab or Shift Tab to move the cursor to the Record Device list box on the Setup 1 tab Press the Up or Down arrow to select an option You can set Record Device to Thermal HP DJ D2468 HP DJ D5568 HP DJ D2668 HP DJ D4368 or HP LJ P2035 HP DJ D2468 HP DJ D5568 HP DJ D2668 HP DJ D4368 and HP LJ P2035 are the types of the USB printer when HP DJ D2468 HP DJ D5568 HP DJ D2668 HP DJ D4368 or HP LJ P2035 is selected you
68. ated Separation distance according to frequency of transmitter m maximum 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz output power of transmitter d 1 2 4P d 1 2 4P d 2 34P W 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 195 SE 12 Series Electrocardiograph User Manual Appendix 3 Abbreviation Abbreviation Abbr English LCD Liquid Crystal Display BP Blood Pressure ECG Electrocardiogram Electrocardiograph HR Heart Rate aVF Left Foot Augmented Lead aVL Left Arm Augmented Lead aVR Right Arm Augmented Lead LA Left Arm LL Left Leg RA Right Arm RL Right Leg ID Identification AC Alternating Current USB Universal Serial Bus AGC Auto Gain Control 196 P N 01 54 455421 10 EDANUSA 4901 Morena Blvd Suite 505 w
69. ation window the physician s name is printed in the ECG reports When Prompt is set to Unconfirmed Unconfirmed Report is printed in the ECG reports 11 4 5 Selecting H W Unit Press Tab or Shift Tab to move the cursor to H W Unit in the Patient Information Setup window and then press the Up or Down arrow to select em kg or inch Ib 129 SE 12 Series Electrocardiograph User Manual System Setup 11 4 6 Selecting BP Unit Press Tab or Shift Tab to move the cursor to BP Unit in the Patient Information Setup window and then press the Up or Down arrow to select mmHg or kpa When BP Unit is set to kpa two extra edit boxes will be displayed in the Patient Information window for inputting decimal fraction 11 4 7 Selecting Next Patient Press Tab or Shift Tab to move the cursor to Next Patient in the Patient Information Setup window Press the Up or Down arrow to highlight Off or On When Next Patient is set to On in the auto mode press the START STOP key to print an ECG report and the system will automatically open the next patient screen after a complete ECG report is printed On the next patient screen pressing the function key F1 below Same Patient can return to the main screen all the patient information will keep the same pressing the function key F2 below Next Patient can return to the main screen all the patient information will be changed except gender pressing F3 can switch the auto recording style pre
70. ation with uncontrolled ventricular rate Hypertrophic cardiomyopathy Patients can not cooperate because of mental impairment High degree AV block 1 3 List of Symbols External output External input Equipment or part of CF type with defibrillator proof Caution Gz Qe yt A AR Consult Instructions for Use SE 12 Series Electrocardiograph User Manual Safety Guidance Potential equalization Mains supply USB socket Battery indicator Battery recharging indicator Delete key Enter key Esc key Reset key Shift key Fn key CGE eGAt ha a ele Power On Off key COP COPY key MODE key SLEEP WAKE UP key START STOP JEE START STOP key SE 12 Series Electrocardiograph User Manual Safety Guidance Tab key Feed paper key SZ UP DOWN LEFT RIGHT Arrow key O S Recycle P N Part Number Serial Number el Date of Manufacture ual Manufacturer Authorized Representative in the European Community The symbol indicates that the device complies with the European Council Directive 93 42 EEC concerning medical devices gl With respect to electrical shock fire and mechanical hazards C US only in accordance with UL 60601 land CAN CSA C22 2 3XM9 No 601 1 Federal US law restricts this device to sale by or on the Rx only U S _ order of a physician It indica
71. be set in the Patient Information window Gender Patient Gender Male Female Empty Hint Information 1 Hint Information 2 Including DEMO Module Error Overload Lead Name When the leads are off the lead names will be shown in black on a yellow background in SE 12 Express while in SE 12 they will be shown in black on a white background Including No Paper Paper Error Battery Weak Sampling Analyzing Recording Testing Learning Transmitting Transmit Fail Detecting Memory Full U Disk USB Printer Lead Off USB Scanner Work Mode Heart Rate Manual Auto Rhythm R R Analysis or Off Actual Heart Rate Current Time Battery Symbol Current examination time Refer to Section 11 8 1 Setting Date and Time Identify the current capacity of the battery Press the function key F7 below File to open the File Manager Fil X screen For details please refer to Chapter 10 Managing Files Press the function key F6 below Setup to display the System Setup Setup screen For details please refer to Chapter 11 System Setup EMG Filter 25Hz 35Hz or 45Hz Lowpass Filter 75Hz 100Hz or 150Hz Filter NOTE This setup can t be saved if it is modified on the main screen 30 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Gain 2 5 mm mV 5 mm mV 10 mm mV 20 mm mvV 10 5 mm mV or AGC NOTE This setup can t be saved i
72. chine i TMX495 5 DP10 wired Sampling Box DEES DP12 wired Sampling Box lt SE serial Machine DEMO Sampling Por COMO Treadmill com1 Protocol Bruce v BP monitor com2 Modify Restore the default 2 Connect USB socket of the electrocardiograph to the USB socket of the PC by using the high speed USB cable 3 Start the real time transmission The electrocardiograph transmits to the PC the ECG signals acquired from the patient Acquisition and transmission are simultaneous The ECG signals are displayed on the PC monitor and eventually analyzed For more details refer to the user manual of the PC ECG software In the real time transmission the function of the electrocardiograph is the same as that of the ECG sampling box 101 SE 12 Series Electrocardiograph User Manual Managing Files Chapter 10 Managing Files If you want to save the ECG data in the electrocardiograph you should set Auto Save to On and Saving Path to ECG By default Auto Save is On and Saving Path is ECG Then the ECG data in the auto off or rhythm mode will be saved on the File Manager screen automatically To Set Auto Save to On and Saving Path to ECG 1 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen 2 Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to File press eJ 3 Press Tab or Shift Tab to move the cursor to the Auto Save list bo
73. cols can be edited and created Automatically controlling and adjusting the speed and grade of the treadmill or the power of the ergometer Supporting multi types of treadmill or ergometer S05 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Chapter 3 About the Electrocardiograph Application The following sections provide an overview of the main operations and functions You can operate the electrocardiograph by using the keyboard For SE 12 Express you can also carry out the operations by using the touch screen CAUTION Do not touch the LCD screen with sharp things such as pencils or pens otherwise it will be damaged 3 1 Selecting Menu Functions Pa g a D ee FIO ee Pia S O O O O O O O amp Cc OC Ea CP eo amp OBEaVIgoagaanovoese i aSHGQGQ8ogenonoavnoa Press F7 below File to select File and SoSogggsonooo o 0 0 0 O O O O OG open the File Manager screen aff O C a wen fa e as Sa CxO oS To select Patient press the function key F1 below Patient To select Setup press the function key F6 below Setup 26 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application 3 2 Entering Data Patient Information ID ooi Name Marry Johnson Age 25 Years d Gender Female 7j Weight 50 kg Height 165 cm 1 When the main screen is displayed press the
74. ctions of the equipment and proper operation procedures before use Please pay more attention to the following warning and caution information SE 12 Series Electrocardiograph User Manual Safety Guidance 1 2 1 Safety Warnings 10 11 12 13 WARNING The electrocardiograph is intended to be used by qualified physicians or personnel professionally trained They should be familiar with the contents of this user manual before operation Only qualified service engineers can install this equipment and only service engineers authorized by the manufacturer can open the shell EXPLOSION HAZARD Do not use the electrocardiograph in the presence of flammable anesthetic mixtures with oxygen or other flammable agents SHOCK HAZARD The power receptacle must be a hospital grade grounded outlet Never try to adapt the three prong plug to fit a two slot outlet Make sure that the power is turned off and the power cord is disconnected from the AC socket before connecting or disconnecting equipment Otherwise electrical shock or other injuries may happen to the patient or operator If the integrity of the external protective conductor is in doubt the equipment should be powered by an internal rechargeable battery Do not use this equipment in the presence of high static electricity or high voltage equipment which may generate sparks Only the patient cable and other accessories supplied by the manufacturer can be used Or else the p
75. diagnosis results may not include the pacemaker information 121 SE 12 Series Electrocardiograph User Manual System Setup 11 3 Record Info Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Record Info on the System Setup screen press to open the Record Info Setup window You can press F1 or F2 to switch between Setup 1 and Setup 2 After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 3 1 Setup 1 Press F1 or F2 to switch to the Setup 1 tab Record Info Setup Save Paper synchrono i Figure 11 4 Record Info Setup1 11 3 1 1 Selecting Auto Recording Style Press Tab or Shift Tab to move the cursor to the Record Style list box on the Setup 1 tab and then press the Up or Down arrow to highlight an option In the auto mode when Record Style is set to 3x4 ECG waves of 12 leads are printed in 4 groups of 3 122 SE 12 Series Electrocardiograph User Manual System Setup In the auto mode when Record Style is set to 3x4 1R ECG waves of 12 leads are printed in 4 groups of 3 with the ECG wave of one rhythm lead on the bottom of the ECG reports In the auto mode when Record Style is set to 3x4 3R ECG waves of 12 leads are printed in 4 groups of 3 with the ECG waves of three rhythm leads on the bottom of the ECG reports In the
76. dow 111 SE 12 Series Electrocardiograph User Manual Managing Files Patient Information ID fool oO Ol First Name Mary Sooo Last Name Johnson O Age 25 Yeas FJ Gender Female Mf Weight 50 _ kg Height 165cm Address NOTE The Address item is customized 1 Press Tab or Shift Tab to move the cursor to a textbox Fill in the selected textbox 2 Press Tab or Shift Tab to move the cursor to a list box Press the Up or Down arrow to select an option 3 After inputting all the information press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm For details on inputting data please refer to Section 3 2 Entering Data 10 7 Printing Files When the main screen is displayed press the function key F7 below File to open the File Manager screen1 Press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Press START STOP or the function key F2 below Record to print the selected file Pressing START STOP or the function key F2 below Stop can stop printing the file 10 8 Previewing a File To Open the File preview screen 1 When the main screen is displayed press the function key F7 below File to open the File Manager screen 2 Press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function
77. ds 12 channels 6 On the System Setup screen press Tab or Shift Tab or the Up Down Left or Right lt arrow to move the cursor When the cursor is on Record Info press to open the Record Info Setup window 7 Press Tab or Shift Tab to move the cursor to the Record Style list box and then press the Up or Down arrow to select a style 67 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Record Info Setup Save Paper Sequential 10 5mm mv AGC i Press lt F1 gt or lt F2 gt to switch page 8 Press ES or press Tab or Shift Tab to move the cursor to the OK button and then press e 9 On the System Setup screen press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Lead press to open the Lead Setup window 10 Press Tab or Shift Tab to move the cursor to the Rhythm Lead1 2 3 list box and then press the Up or Down arrow to select a lead 11 Press Tab or Shift Tab to move the cursor to the Lead Sequence list box and then press the Up or Down arrow to select a sequence 12 Press me or press Tab or Shift Tab to move the cursor to the OK button and then press Ea 68 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Lead Setup Rhythm Leadi Rhythm Lead2 Rhythm Lead3 Lead Sequence Cabrera On After setup press ESC to return to the main screen 2 When the main screen
78. e 6x2 15 Record Mode Save Paper 16 Record Sequence Sequential 17 Gain 10mm mV 18 Record Device Thermal 19 Speed 25mm s 20 Paper Marker Yes 21 Sample Time 10s 22 Patient Information On 23 Template On 24 Position Marker On 25 Measure On 26 Analysis On 145 SE 12 Series Electrocardiograph User Manual System Setup 146 27 Minnesota Code Off 28 Baseline Adjustment Horizontal 29 R R Histogram On 30 R R Interval List On 31 R R Waveform On 32 Grid of Thermal Report Off 33 Grid of USB Report On 34 Gender Height Weight On First Last Name D O B BP Race Hi eee or Technician Ref Physician 36 ID Hint On 37 Next Patient Off 38 ID Mode Auto 39 Patient Information Cleared After Recording 40 H W Unit cm kg 41 BP Unit mmHg 42 Prompt Confirmed By 43 User Defined Cleared 44 Auto Transmission Off 45 Transmission Mode Ethernet 46 FTP User Name FTP Password FTP Cleared Path 47 Lead Sequence Standard 48 Nehb Off 49 Rhythm Lead 1 II 50 Rhythm Lead 2 Vi 51 Rhythm Lead 3 V5 59 Screen Colors Only for SE 12 dmon Express SE 12 Series Electrocardiograph User Manual System Setup 53 Antialiasing Off 54 QRS Volume Off 55 Hint Volume Medium 56 Key Volume Medium 57 Date Mode DD MM YYYY 58 Time Mode 24 Hours 59 Power Off 0 60 LCD Off 0 61 Auto Save O
79. e Setup window and then press the Up or Down arrow to highlight DD MM YYYY MM DD YYYY or YYYY MM DD NOTE After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the new setup will become effective 139 SE 12 Series Electrocardiograph User Manual System Setup 11 8 3 Setting Time Mode Press Tab or Shift Tab to move the cursor to the Time Mode list box and then press the Up or Down arrow to highlight 24 Hours or 12 Hours 11 8 4 Setting Power Off Time Press Tab or Shift Tab to move the cursor to the Power Off textbox in the Date amp Time Setup window and then input the power off time manually When Power Off is not set or is set to 0 Minutes this function will not be effective NOTE 1 Power off time is counted from the time when you last press the keys on the keyboard 2 Only when the device is powered by battery can the set automatic power off time be effective 11 8 5 Setting LCD Off Time Press Tab or Shift Tab to move the cursor to the LCD Off textbox in the Date amp Time Setup window and then input the LCD off time manually When LCD Off is not set or is set to 0 Minutes this function will not be effective NOTE LCD Off time is counted from the time when you last press the keys on the keyboard 11 9 File Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on F
80. e dialog box The annotations will be displayed in the summary report Press this key again to close the dialog box Speed W Press Speed W to change the speed of the treadmill during the exercise phase NOTE The two keys are available for the customized treadmill protocol only Grade Press Grade to change the grade of the treadmill during the exercise phase NOTE The two keys are available for the customized treadmill protocol only 14 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Start Stop tmill Before the exercise test press Start tmill to test the connection between the electrocardiograph and the treadmill and then press Stop tmill to stop the connection test Function Key Selecting menu functions on the screen Delete Deleting characters Enter Confirming operation Tab Feed paper Moving the cursor Pressing Tab can move the cursor forward and pressing Shift Tab can move the cursor backward Feed paper when the main screen is displayed if Paper Marker is set to Yes you can press the Tab key to advance the recorder paper to the next black marker if Paper Marker is set to No you can press the Tab key to advance the paper for 2 5cm Press the Tab key again to stop advancing the paper Fn Inputting special characters Press Fn a to type Spacebar Adding a space between typed characte
81. e positions of the calibration lines The 3 leads can be selected in the Lead Setup window of the exercise test 3 6 About the System Setup screen When the main screen is displayed press the function key F6 below Setup to display the System Setup screen NOTE If you set the system password in the System Maintenance window you need enter the password before opening the System Setup screen For details refer to Section 11 10 7 Setting System Password 45 s SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application System Setup Work Mode Record Info Patient Info On the System Setup screen press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on an item press to open the setup window of the item Take the Work Mode Setup window for example Work Mode Setup Mode Options 3x4 Pre Sample Iv Check MANU 3x4 1R Box AUTO 3x4 3R Triggered Sample M RHYT 5 Periodic Sample 6x2 1R Textbox RR 12x1 Periodic Sample Setu OFF Duration 60 min Interval oi min Manual Style Rhythm Style Preview Dropdown List 3 channels Single Lead off Box 12 channels Auto Extend Record Off Press lt Tab gt or lt Shift Tab gt to move the cursor 1 In the Work Mode Setup window press Tab or Shift Tab to move the cursor among different check boxes Press Spacebar to select a check box and a check mark V appears in the box
82. e selected protocol as the default protocol 4 Delete Select a protocol on the Protocol Manager screen by pressing the Up or Down arrow and press the function key F4 below Delete to display the following dialog box Press Tab or Shift Tab to move the cursor to the OK button and then press to delete the selected protocol Cancel 172 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional 5 Del All To delete all the protocols from the Protocol Manager screen you can press the function key F5 below Del All to display the following dialog box Press Tab or Shift Tab to move the cursor to the OK button and then press to delete all the protocols Cancel 6 Restore Press the function key F6 below Restore to display the following dialog box Press Tab or Shift Tab to move the cursor to the OK button and then press to restore the factory settings Cancel 7 Return Press the function key F7 below Return to return to the System Setup screen 173 SE 12 Series Electrocardiograph User Manual Turning off the Electrocardiograph Chapter 13 Turning off the Electrocardiograph When the battery is used hold down the key to display the hint System is shutting down on the screen Then the device will be off a few seconds later When the mains supply is used hold down the key to display the hint System is shutting down on the screen Then t
83. e ssccctsscccctsvacaessiigecnavncectcascesaeStvsncceioeanseieies 106 10 1 3 Transmitting SCP FDA XML PDF Files through Net Cable s sessssesseeseesesseseesess 107 10 2 Exporting Files to the U Disk nsnnisenercorecnarece ein nia i i 108 10 3 Deleting Files ys nna y a ae EAEE E EREE E E A EEKE 109 TO ASS tC ITO ISS os foo e a a a e ea eannat enue ua aceaen oes 110 10 5 Importing AUS Suse ssciciess ths cet ana a a a e a 111 IV 10 6 Editing Patient Information iis 2 edsavsasash deltas sot evaccs bixennateaesusesdaedtas vixen akleaginaassaeoanseeaateaiaes 111 10 7 Printinge SN Car ae eran nc MONEE ered ee teeree Mer ror ae nny te Peer emma Bere en tay oe reer e meine te 112 10 8 Previewmg a Ey lil rap recite oer one Re gee Peer ee er e RUSE Pee a eT mere ae 112 Chapter 11 Syst m Seti ssccseicscccacvecpcckoncececaceesveecssasitsiiececsvencbs ne cadveevcuseonassaacvesseaceveedededeecseateveeee 115 11 1 Work Mode Setipiicn aiceissse dens anidne ew hae aude eases Ca has eed 115 hid Selecta Work Mode ep cercacesecedeucsscugences een beatsasuaeeeaonneaccaentsGiameingeramnntees 116 Ligh Selects Manual Stylesin latte lau a a a a a e a tases olen ee 117 Ti Tes Selecting Rhythm Style sesrenieec nnn a n a E a a 117 Te 14 Selecting Auto Display Styler eiiieaen e E n RE EER A a ai 117 LS Selecting Sampling Modersssireinasininente niara dina E a 118 11 1 6 Setting Interval and Duration ssssnseseessseeseeseesseesresresseesesessseessesersstessessrs
84. ecord Return 4 Press the function key F4 below Diagnosis to show Minnesota Code and Diagnosis Information 00i Marry Johnson Minnesota Code 9 4 1 V3 Diagnosis Information 800 Sinus Rhythm Waveform Template Measure _ Diagnosis 5 Press START STOP or the function key F5 below Record to print the file Pressing START STOP or the function key F5 below Stop can stop printing the file 6 Press the function key F7 below Return to return to the File Manager screen2 NOTE Rhythm data can not be previewed 114 SE 12 Series Electrocardiograph User Manual System Setup Chapter 11 System Setup After you turn on the device the main screen pops up Press the function key F6 below Setup to display the System Setup screen System Setup Work Mode Record Info Patient Info Figure 11 1 System Setup screen After setup 1 Press ESC to return to the main screen 2 Or press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to Return and then press to return to the main screen 11 1 Work Mode Setup When the cursor is on Work Mode on the System Setup screen press to open the Work Mode Setup window 115 SE 12 Series Electrocardiograph User Manual System Setup Work Mode Setup Pre Sample Real time Sample Triggered Sample Periodic Sample Single lead for Three Leads of se iB Figure 11 2 Work Mode Setup window After setup press to confirm o
85. ect current offset voltage on an electrode is too high No Testing No test is being carried out Testing An exercise test is being carried out Testing Stop An exercise test is terminated HR Overrange Heart rate exceeds the normal range Sys Overrange Systolic blood pressure exceeds the normal range Dia Overrange Diastolic blood pressure exceeds the normal range 176 Hint Information SE 12 Series Electrocardiograph User Manual Cleaning Care and Maintenance Chapter 15 Cleaning Care and Maintenance CAUTION 1 Turn off the power before cleaning and disinfection The mains supply must be switched off if it is used 2 Prevent the detergent from seeping into the equipment 15 1 Cleaning CAUTION Any remainder of detergent should be removed from the unit and the patient cable after cleaning 15 1 1 Cleaning the Main Unit and the Patient Cable To clean the electrocardiograph 1 Unplug the AC power cord 2 Wipe the external surfaces of the electrocardiograph with a soft cloth dampened in any of the approved cleaning solutions listed below To clean the patient cable 1 Dampen a soft cloth with one of the disinfectants or cleaning agents listed below 2 Wring excess moisture from the cloth before cleaning Recommended Cleaning Solutions Mild soap and water 75 alcohol 15 1 2 Cleaning the Reusable Electrodes To clean reusable electrodes 1 Remove the remainder gel from the electrodes with
86. eeeeeeseeeaeenes 84 8 6 5 ECG Reports Printed by the USB Printer ii saccasscasceadveedactesatssaredextocqaasts ders veetectedetetedent 88 8 6 6 ECG Report of Patient with Pacemaker sssseseesessseessesesssesseserssessessessressessrssressesse 89 8 6 7 ECG Report of Nebb Lead ir zy ccsas sages cuore te hanhezischonde cenessein tan eeBetta ghszeadeewdvesucgaeherahaeoseunes 90 Chapter 9 Transmitting ECG Data Automaticallly ccscccssssssssccssssccssscccsssscesssscsssesceseeses 92 9 1 Transmitting ECG Data t the PC siiu aron das a AER RT Pakaa AAEE SAART EA Eosi 92 9 1 1 Transmitting ECG Data in DAT Format through Serial Cable 0 eee eeeeeeereeeeeeneeees 92 9 1 2 Transmitting ECG Data in DAT Format through Net Cable esseseseseseesessessereessesee 94 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format through Net Cable 97 9 2 Exporting ECG Data to the U Disk Automatically cece eeceeseeseeeeceeecesecneeeaeeeseseeeeseenaes 99 9 3 Real time Transmission to PC ECG s sessssessesessssessessrssressessrssresseeseesresseesesressressessressesse 100 Chapter 10 Managing Files escseccoecsscossocssocccoceccoesosoesococsececosscoocsosoesococsosecossesscssocesosossssscossee 102 LO Transmitting Files to the PC fst etna tin ates esas celal a have e a i oE E EAE 104 10 1 1 Transmitting DAT Files through Serial Cable cece eeceseeceeeeceeeceeecneeeeeeeeeeeeeeaees 105 10 1 2 Transmitting DAT Files through Net Cabl
87. en 2 Connect the bar code reader to USB socket 2 on the right panel of the electrocardiograph 3 When the main screen is displayed scan the patient s bar code with the bar code reader and then the patient information will appear in the corresponding box NOTE Only bar code readers recommended by the manufacturer can be used 63 SE 12 Series Electrocardiograph User Manual Freezing ECG Waves Chapter 7 Freezing ECG Waves You can freeze the ECG waves displayed on the main screen Operation Method 1 Press the function key F2 below Freeze to display the freezing screen NOTE Within ten seconds after returning to the main screen pressing the function key F2 can not display the freezing screen 001 F AUTO 12 00 01 Marry Johnson 25Y my Figure 7 1 freezing screen 2 Press the function key F3 to set the paper speed press the function key F4 to set the gain press the function key F5 to set the filter and press the function key F6 to set the printing style NOTE When you press the function key F7 below Return to exit the freezing screen these settings will not be saved 3 Press the function key F2 below Replay to replay the frozen ECG waves on the Replay screen 64 SE 12 Series Electrocardiograph User Manual Freezing ECG Waves 4 5 6 7 8 12 00 01 v6 x J je Pre Sec Next Sec Next Page Play Return Figure 7 2 Replay screen Press F1 below Pre Page or F4 below Ne
88. en the Patient Information window Press Tab or Shift Tab to move the cursor When the cursor is in the ID textbox enter the patient ID manually 7 Press E or press Tab or Shift Tab to move the cursor to the OK button and then press E NOTE In the auto rhythm or off mode when ID Mode is set to Manual and ID Hint is set to On if you do not input the patient ID before pressing the START STOP key a hint will pop up to remind you to input the patient ID 6 2 Entering Other Information When the main screen is displayed press the function key F1 below Patient to open the Patient Information window Patient Information ID oo OOO l First Name Mary its Last Name Johnson D O B loi los 1975 Age BS Years F Gender mae M Weight 50 kg Height 170 cm Pacemaker o M BP 110 100 mmHg Race Unknown FJ Medication Room No 305 Department Physician Technician Ref Physician s s S 58 SE 12 Series Electrocardiograph User Manual Entering Patient Information First Name Within 30 ASCII characters Last Name Within 30 ASCII characters Age Age Unit Years Months Weeks or Days Gender Patient Gender Male Female Empty Weight kg Patient Weight Range 0 999 Height cm Patient Height Range 0 999 Pacemaker If you select Pacemaker in the Patient Information Setup window Pacemaker appears in the Patient Information windo
89. er 1 200 Name ID Time Mode Marry Johnson 00i 2010 04 08 10 50 26 AUTO Figure 3 7 File Manager screen2 38 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Name Explanation Press the function key F1 below Trans All to transmit all the files A Trans All to the PC Press the function key F2 below Export All to export all the files B Export All f from the electrocardiograph to the U disk Press the function key F3 below Del All to delete all the files from C Del All the electrocardiograph Press the Up or Down arrow to highlight a file on the File Manager D Select screenl and then press the function key F4 below Select to select the file and display the File Manager screen2 Press the function key F5 below Search to open the SearchInfo E Search Setup window Press the function key F6 below Import to import files from the U F Import f disk to the electrocardiograph Press the function key F7 below Return to return to the main G Return screen Edit Press the function key F1 below Edit to open the Patient i Information window Then you can edit the patient information I Record Press the function key F2 below Record to print the selected file J T Press the function key F3 below Trans to transmit the selected file rans to the PC K Boat Press the function key F4 below Export to export the selected file xpor from the electrocardiograph to t
90. erformance and electric shock protection can not be guaranteed The electrocardiograph has been safety tested with the recommended accessories peripherals and leads Make sure that all electrodes are connected to the patient correctly before operation Ensure that the conductive parts of electrodes and associated connectors including neutral electrodes do not come in contact with earth or any other conducting objects Electrodes with defibrillator protection should be used while defibrillating If reusable electrodes with electrode gel are used during defibrillation electrocardiograph recovery will take more than 10 seconds The manufacturer recommends the use of disposable electrodes at all times Electrodes of dissimilar metals should not be used otherwise it may cause a high polarization voltage SE 12 Series Electrocardiograph User Manual Safety Guidance 14 15 16 17 18 19 20 21 22 23 24 25 WARNING The disposable electrodes can only be used for one time No hazard is found when the electrocardiograph is operated with cardiac pacemakers or other stimulators Do not touch the patient bed table or the equipment while using the ECG together with a defibrillator Do not touch accessible parts of non medical electrical equipment and the patient simultaneously The use of equipment that applies high frequency voltages to the patient including electrosurgical equipment and some respi
91. eries Electrocardiograph User Manual Printing ECG Reports As the above figure shows the ECG report printed by the USB printer includes Institution Name Date and Time Patient Information Measurement Information Diagnosis Information Report Confirmed by ECG waves of 12 leads DFT Filter Lowpass Filter AC Filter Paper Speed Gain SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm Version Number 8 6 6 ECG Report of Patient with Pacemaker 22 06 2010 15 06 16 981 ID 7 001 HR 7 80 BPM Diagnosis Information Name Marry Johnson P Dur 10I ms 421 Artificial Pacemaker Rhythm Age 25 Years Gender Female PR int 176 ms Height 165 cm Weight 50 kg QRS Dur 80 ms Room No 0023 QT QTC int 339 391 ms Department P QRS T axis 30 42 46 P RVS SV1 amp 1 148 0 603 mV RVS SV1 amp 1 751 mV RV6 SV2 amp 0 811 1 007 mV Report Confirmed by See rene S Beis a DAE DE A yhe GHH hh deaa Heh arar r aah HS SL AnEE EREA EE OE A koee e ah H a a Hoea sH He a PSOne ence ka 0 67 150Hz AC50 25mm s 10mm mV 2 5s 1r Institution Name SE 12 EXPRESS VES SEMIP VES The above figure shows the ECG report of a patient with a pacemaker Pacemaker Detection Sens is set to High and the Lowpass filter is set to 150Hz 89 SE 12 Series Electrocardiograph User Manual Printing ECG Reports NOTE 1 To the patient with a pacemaker
92. ersion Number Figure b shows Patient Information Measure Information Diagnosis Information Average Template Report Confirmed by Current Date and Current Time 0 67Hz DFT Filter 100Hz Lowpass Filter ACS50 50Hz AC Filter 25mm s Paper Speed 10mm mV Gain Institution Name SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm Version Number Patient Information includes ID Name Age Gender Height Weight Room No Department Measure Information includes HR Heart Rate P Dur P wave duration the average P wave duration from several selected dominant beats PR int P R interval the average P R interval from several selected dominant beats QRS Dur QRS complex duration the average QRS complex duration from several selected dominant beats QT QTC int Q T interval the average Q T interval from several selected dominant beats Normalized QT interval P QRS T axis Dominant direction of the average integrated ECG vectors RV5 SV1 amp The maximum of the amplitude of R or R wave of one selected dominant beat from lead V5 The maximum absolute value of the amplitude of S or S wave of one selected dominant beat from lead V1 RV5 SV1 amp Sum of RV5 and SV1 RV6 SV2 amp The maximum of the amplitude of R or R wave of one selected dominant beat from lead V6 The maximum absolute value of the amplitude of S or S wave of one selected do
93. esooesoocesscessecesocssoosssosesso 57 Gl Entering Patient Daanan eaea a a a aes Aes 57 6 2 Entering Other Information ss sssssessseseesseesseseossessesrrsstessesstssressesstsstesseestesesseeseesresseseest 58 6 3 Usmg Bar Code Reader esi gen nats sislos se ea a op Mase vs e eee aves eae 60 Chapter 7 Freezing ECG Waves seeseseeseesessossesossossesoosossossossesossossesossossessosoesossossesossossessossesossose 64 Chapter 8 Printing ECG Reports esssecssecesocesooessseessecssocesocesoosesocesoecesocssooesoocesseessccesocesoosssosesse 66 EIO AN TS AE E A T TE E a a E E A E S 66 8 2 Manul Modei n iae e a E aeai EEEE aR E ET Eaa iai 70 8 3 Roby thins Mode tes coteeaess e i Maas otis Rig ers Cai a An EE ase E RO a 12 8 4 RRAn lysis IOUS lt tc atta aten ic chest ccriates encodes eat Goat a as chin Zalte ees a eB E a aia 74 SS COP PINUNO os ae Sa eG Tac Oren ts daca eae a Ted Mea tina la els ened T A Ded Mate ae a tea Eade 76 SOECG REPOS irnar ennei a o i a Auamed pol decudesdbawtten E O T ES 77 8 6 1 ECG Reports inthe Atta Mod x 05 cased sccshlassnedasieiadaesaussaauaccas taadorauseeinces aaa RT iais TT 8 6 2 ECG Reports in the Rhythm Mode sssssennessensseeseesessseessesessssesseserssressessrssressessesseessesse 82 8 6 3 ECG Reports in the Manual Mode ssssesseseeseessesseseesseesessrsssesstsseesseeseesresseesseseesseesse 83 8 6 4 ECG Reports in the R R Analysis Mod e cccceeccesscesssecseceeeceeeeesseecsaeceaec
94. ess 12 1 Activating Exercise ECG Function 1 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen 2 Press F1 to display the Service Password window Then enter the password and press to open the Advanced Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to Function and then press to open the Function Configuration window Advanced Setup 156 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional Function Configuration Return 3 Press Tab or Shift Tab to move the cursor to the Activate button after Stress Test Press to open the Activate Password window Enter the password and press to activate the exercise ECG function Function Configuration Enabled NOTE Please contact local distributors to get the service password and the activating password 12 2 Operation Preparation 1 Turn on the electrocardiograph NOTE Turn on the electrocardiograph before connecting the treadmill or the ergometer or else the start up of the electrocardiograph may be abnormal 2 Connect the electrocardiograph to the treadmill or the ergometer 157 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional CAUTION Only the treadmill ergometer recommended by the manufacturer can be connected to Serial Port 1 and Serial Port 2 1 Con
95. ess Tab or Shift Tab to move the cursor to the OK button and then press Ce On the System Setup screen press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Lead press to open the Lead Setup window Press Tab or Shift Tab to move the cursor to the Rhythm Lead1 list box and then press the Up or Down arrow to select a lead Press Ce or press Tab or Shift Tab to move the cursor to the OK button and then press Ce 75 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Lead Setup Standard Cabrera After setup press ESC to return to the main screen 2 When the main screen is displayed press the MODE key to select the R R analysis mode Press F4 to switch the gain Press F5 to set the EMG filter or the Lowpass filter 3 Press the START STOP key to begin to count the sampling time When the sampling time reaches 180s it begins to print an ECG report 4 It will stop automatically after a complete R R analysis report is printed or press the START STOP key to stop printing the ECG report NOTE In the R R analysis mode you can not set the speed The constant speed is 25mm s and the printing speed is 5mm s because in the R R analysis mode the ECG wave length is compressed to one fifth of the original wave length 8 5 Copy Printing In the auto mode pressing the COPY key can print the ECG report which was printed out last time Pressing t
96. f it is modified on the main screen N Gain In the manual mode you can set Speed to 5mm s 6 25mm s 10mm s 12 5mm s 25mm s or 50mm s In the auto and rhythm modes only 25mm s and 50mm s are available In the R R O Speed analysis mode only 25mm s is available NOTE This setup can t be saved if it is modified on the main screen Freezing ECG waves For details please refer to Chapter 7 P Freeze Freezing ECG Waves Press the function key F1 below Patient to open the Patient Q Patient Information window For details please refer to Chapter 6 Entering Patient Information R ECG waveform Display ECG waveform 3 5 About the main screen of Exercise ECG Optional for SE 12 Express After turning on the electrocardiograph press Pretest on the keyboard to open the main screen of the exercise test Figure 3 3 During the exercise test the main screen of ST Trend Figure 3 4 or the main screen of Template Figure 3 5 will appear ae 4s SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application mee i n a a c L B A M U oS S R7 Q P7 o7 N Bruce Exercise Stage 1 No Paper Testing 00 02 20 00 00 40 Marry Johnson 001 1 7 mph 10 0 x 7 0 mets ST Amplitude 1 ST Amplitud min Patient Hold Postt 60ms 10mm my __100nz idad Template A V W Figure 3 4 Main screen of ST Trend z392 SE 12 Series Electrocard
97. f one rhythm lead on the bottom When the auto display style is set to 3x4 3R ECG waves of 12 leads are displayed in 4 groups of 3 with ECG waves of three rhythm leads on the bottom When the auto display style is set to 6x2 ECG waves of 12 leads are displayed in 2 groups of 6 When the auto display style is set to 6x2 1R ECG waves of 12 leads are displayed in 2 groups of 6 with the ECG wave of one rhythm lead on the bottom When the auto display style is set to 12x1 ECG waves of 12 leads are displayed on one screen simultaneously 11 1 5 Selecting Sampling Mode Press Tab or Shift Tab to move the cursor to the Sampling Mode list box in the Work Mode Setup window and then press the Up or Down arrow to highlight an option When Sampling Mode is set to Pre Sample 10s ECG data sampled before pressing the START STOP key will be printed out NOTE When Sampling Mode is set to Pre Sample if you press the START STOP key before the electrocardiograph samples for 10s the recorder will not respond When Sampling Mode is set to Real time Sample 10s ECG data sampled after pressing the START STOP key will be printed out When Sampling Mode is set to Triggered Sample after pressing the START STOP key if Arrhythmia ECG data including Asystole Ventricular Fibrillation Ventricular Tachycardia 5 gt PVCS gt 3 Paired PVCS Bigeminy Trigeminy R ON T single PVC and Missed Beat is detected during the learning course the printing will
98. f the Gateway item to the first three sections of the IP of the electrocardiograph The last section of the Gateway item must be set to 1 Commonly Subnet Mask is set to 255 255 255 0 Transmission Setup 92 tics A7 ff 8 Press E or press Tab or Shift Tab to move the cursor to the OK button and then press 9 Press ESC to return to the main screen 3 Log into the Smart ECG Viewer software 4 In the auto or rhythm mode ECG data will be transmitted through the net cable automatically after an ECG report is printed out In the off mode ECG data will be transmitted through the net cable automatically after the START STOP key is pressed 96 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Automatically 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format through Net Cable 1 Activate SCP FDA XML PDF function on the Advanced Setup screen 1 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen 2 Press F1 to display the Service Password window Then enter the password and press to open the Advanced Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to Function and then press to open the Function Configuration window Advanced Setup Function Configuration SCP Activate FDA XML Activate PDF Activate Stress Test Activate Return 97 SE 12 Series
99. ff the treadmill Remind patients to take care not to fall down from the treadmill Keep hands hair jewelry and loose clothing away from moving parts of the treadmill After the exercise test slow the speed of the treadmill to the minimum and then stop the treadmill Children are prohibited from approaching the treadmill ergometer alone Don t insert anything into the treadmill or place anything on its surface Press down the emergency stop switch to stop the treadmill immediately an 1 2 6 Contraindications for SE 12 Express Exercise ECG Absolute Contraindications 1 Acute MI within 2 days 2 High risk unstable angina a Hemodynamic compromise caused by uncontrolled cardiac arrhythmia 4 Active endocarditis 5 Symptomatic severe aortic stenosis SE 12 Series Electrocardiograph User Manual Safety Guidance 9 Decompensated symptomatic heart failure Acute pulmonary embolus or pulmonary infarction Acute noncardiac disorder that may affect exercise performance or be aggravated by exercise eg infection renal failure thyrotoxicosis Acute myocarditis or pericarditis 10 Physical disability that would preclude safe and adequate test performance 11 The patient opposes the test Relative Contraindications 1 N Re ot o o oe o Left main coronary stenosis or its equivalent Moderate stenotic valvular heart disease Electrolyte abnormalities Tachyarrhythmias or bradyarrhythmias Atrial fibrill
100. formation please refer to Chapter 6 Entering Patient Information NOTE If you do not enter the patient age or the birthday before pressing the Pretest key to begin the exercise test a hint will pop up to remind you to input the patient age 12 3 Exercise Test Attach all the electrodes to the patient Apply the stress BP monitor to the patient Press the Pretest key to begin the pretest phase After pretest the patient can get on the treadmill or the ergometer Press the Exercise key to enter the exercise phase and then observe the ECG waveforms heart rate blood pressure and the patient s state When the target heart rate is reached press the Recovery key to enter the recovery phase and then observe the ECG waveforms heart rate blood pressure and the patient s state When the patient s heart rate resumes the normal value press the Test end key to terminate the exercise test Take off the patient cable and electrodes Press START STOP to print the summary report ST scope report and trend graph report Pressing START STOP again can stop printing the reports 164 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional 12 4 System Setup for Exercise Test After turning on the electrocardiograph press Pretest on the keyboard to open the main screen of the exercise test Press the function key F6 below Setup to open the System Setup screen System Setup Figu
101. ging Files HINT 6 Or press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Press the function key F3 below Trans to transmit the selected file to the PC 10 1 3 Transmitting SCP FDA XML PDF Files through Net Cable 1 Activate SCP FDA XML PDF function on the Advanced Setup screen For details refer to Section 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format Through Net Cable 2 Set file format to SCP FDA XML PDF When the main screen is displayed press the function key F6 below Setup to open the System Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to File press to open the File Setup window Press Tab or Shift Tab to move the cursor to File Format and then press the Up or Down arrow to select a format File Setup On U Disk Off kd ok 3 Transmit SCP FDA XML PDF files through the net cable 1 Connect the electrocardiograph to the network of the PC with an Ethernet cable recommended by the manufacturer If the wireless AP transmission is used connect the PC to the server wireless AP and connect the electrocardiograph to the client wireless AP Only the wireless AP recommended by the manufacturer can be used 107 SE 12 Series Electrocardiograph User Manual Managing Files 2 Log into the FTP receiving software The
102. h to the Transmitting PC through the net or serial cable in the auto rhythm or off mode ECG data fails to be transmitted from the electrocardiograph to the Transmit Fail PC through the net or serial cable in the auto rhythm or off mode The amount of files on the File Manager screen of SE 12 exceeds 100 Memory Full The amount of files on the File Manager screen of SE 12 Express exceeds 200 Module Error There is something wrong with the signal sample module DEMO The system is in the demonstration mode Overload The direct current offset voltage on an electrode is too high U Disk USB Printer A U disk a USB printer or a bar code reader is connected to the USB Scanner USB interface 175 SE 12 Series Electrocardiograph User Manual Table 14 2 Hint Information and Causes for Exercise ECG Hint Information Causes Battery Weak The battery is weak No Paper Recorder paper runs out or is not loaded When Paper Marker is set to Yes the electrocardiograph advances the recorder paper to the next black marker If it Paper Error advances the paper for 300mm and can not find the next black marker the hint Paper Error is displayed Module Error There is something wrong with the signal sample module DEMO The system is in the demonstration mode Lead X off Electrodes fall off the patient or the patient cable falls off the unit Overload The dir
103. he START STOP key can stop printing the ECG report 76 SE 12 Series Electrocardiograph User Manual 8 6 ECG Reports 8 6 1 ECG Reports in the Auto Mode 8 6 1 1 Example of 6x2 1R Save Paper Mode 02 06 2010 16 51 43 Printing ECG Reports ID 001 HR 60 BPM Diagnosis Information Name Marry Johnson P Dur 94 ms 00 Sinus Rhythm Age 25 Years Gender Female PR int 170 ms Normal ECG Height 165 cm Weight 50 kg QRS Dur 82 ms Room No 0023 QT QTC int 355 355 ms Department P QRS T axis z 55 45 54 X RVS SV1 amp 1 042 0 533 mV RV5 SV1 amp 1 575 mV RVG6 SV2 amp 0 739 0 879 mV Report Confirmed by n Vi ob eee ce LEE See SH Ges een L tes RE A ERLEEN TERE f 1 Gon tooo oan fh if T if ak ie A s3 yl p i i ot ey a Ba EB ee EES sc FS d RARE E den I p l BLA B Ft ai es BE Hele a as Hs EE E Ba Ad A ea At f f i aV r i j au SISO N yp I i D A oa saa LS i i 175 i iV tf aaa Aa A EF j jl I f aVF Ni v jl i ae a Te EEE Jy ee i 1 I Nets 4 z 4 Wh tN eels K 0 67 100Hz AC50 25mm s 10mm mV 2 5st 1r Institution Name SE 12Express V1 8 SEMIP VI S The above figure shows an ECG report in the auto mode The style is 6x2 1R The ECG report includes Patient Information Measure Information
104. he U disk Press the function key F5 below Delete to delete the selected file L Delete from the electrocardiograph Press the function key F6 below Preview to open the file preview M Preview screen Press the function key F7 below Return to return to the File N Return Manager screen 39 SE 12 Series Electrocardiograph User Manual Operation Preparations Chapter 4 Operation Preparations WARNING Before use the equipment patient cable and electrodes should be checked Replace them if there is any evident defectiveness or aging which may impair the safety or the performance and make sure that the equipment is in proper working condition 4 1 Power and Earthing WARNING If the integrity of the external protective conductor is in doubt the equipment should be powered by battery Power Supply The electrocardiograph can be powered by either the mains supply or battery Mains Supply The mains socket is on the rear panel of the unit If the mains supply is used connect the power cord to the socket first and then connect the power cord to the hospital grade outlet Operating voltage 100V 240V Operating frequency 50Hz 60Hz Input current 0 9 0 4A Make sure that the mains supply meets the above requirements before power on and then ly ee eas 7 press on the keyboard to power on the unit The mains supply indicator 0 is lit If the battery is weak when the mains supply is used it will be recharged aut
105. he device will be off a few seconds later Remove the plug from the outlet NOTE 1 When turning off the device follow the above sequence strictly or else there will be something wrong on the screen 2 Do not hold down the key when the device displays the hint information System is shutting down on the screen 2174 SE 12 Series Electrocardiograph User Manual Hint Information Chapter 14 Hint Information Hint information and the corresponding causes provided by the electrocardiograph are listed in the following tables Table 14 1 Hint Information and Causes Hint Information Causes Lead off Electrodes fall off the patient or the patient cable falls off the unit ead o or a high polarization voltage occurs Battery Weak The battery is weak No Paper Recorder paper runs out or is not loaded When Paper Marker is set to Yes the electrocardiograph advances the recorder paper to the next black marker If it Paper Error advances the paper for 300mm and can not find the next black marker the hint Paper Error is displayed Testing The ECG data is being sampled periodically Sampling Analyzing E ae ae AE ECG signals are being sampled analyzed recorded Recording i The self study process of arrhythmia arithmetic in the Trigger Learning Sample mode The examining process of arrhythmia data in the Trigger Sample Detecting mode atl ECG data is being transmitted from the electrocardiograp
106. ile on the System Setup screen press to open the File Setup window 140 SE 12 Series Electrocardiograph User Manual System Setup File Setup Cancel Figure 11 11 File Setup window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 9 1 Selecting Auto Save Press Tab or Shift Tab to move the cursor to the Auto Save list box in the File Setup window and then press the Up or Down arrow to highlight Off or On When Auto Save is set to On ECG data in the auto rhythm or off mode will be saved in the ECG or the U disk automatically When Auto Save is set to Off ECG data will not be saved 11 9 2 Setting Saving Path Press Tab or Shift Tab to move the cursor to the Saving Path list box in the File Setup window and then press the Up or Down arrow to highlight ECG or U Disk When Saving Path is set to ECG if Auto Save is set to On ECG data in the auto rhythm or off mode will be saved in the ECG automatically When Saving Path is set to U Disk if Auto Save is set to On ECG data in the auto rhythm or off mode will be saved in the U disk automatically 141 SE 12 Series Electrocardiograph User Manual System Setup 11 9 3 Setting File Format Press Tab or Shift Tab to move the cursor to File Format in the File Setup window and then press the Up or Down arrow to highlight an option If you want t
107. ill pop up when you press function keys 103 SE 12 Series Electrocardiograph User Manual Managing Files HINT No file CAUTION 1 When files are being printed transmitted deleted or exported you can not turn off the electrocardiograph 2 Do not cut off the mains supply directly when no battery is installed in the device or else the stored data may be lost 10 1 Transmitting Files to the PC NOTE 1 To transmit DAT files to the PC the Smart ECG Viewer software of the manufacturer must be installed in the PC You should log into the Smart ECG Viewer software before transmission 2 To transmit SCP FDA XML PDF files to the PC the FTP receiving software must be installed in the PC You should log into the FTP receiving software before transmission 3 By default the ECG file format is DAT You can activate SCP FDA XML PDF function on the Advanced Setup screen For details refer to Section 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format Through Net Cable 4 If you select Delete After Trans Or Export in the File Setup window the files will be deleted from the File Manager screen after they are transmitted CAUTION It is forbidden to connect or disconnect a U disk or a USB printer during the transmission course 104 SE 12 Series Electrocardiograph User Manual Managing Files 10 1 1 Transmitting DAT Files through Serial Cable Connect the RS232 socket of the PC to the
108. ing Next Patient cect Svaancaveva sate at sn aaa a a R acts 130 11 4 8 Setting the Time to Clear Patient Information ccc ceeeeseeseeeeeseceeeeeeeeeeeeeeeeeaes 131 11 4 9 Inputting Customized Information ccc ccceceseceseceeeeeeseeceeeeaeceseeeeeeenseeesseeneeeaes 131 14 3 FEATS SS TOT SET eis 13 ccs Goteeacecautaeduus da eN a E as cbimantewanryanecica E T a Ni 131 Lt lSetine Device Noso a Gre ueicla se dep ya edocs N E Mee cen a aha Mee Tau Ss tata dcn ide 132 L152 Selecting Auto Transmission siriac ninan oendales Saami nia a a 133 11 5 3 Selecting Transmission Mode ssssnsssessesseeseesseeseeseesseessesresseessesersstessessessressessessees 133 11 5 4 Setting FIP Infomation nenie eian a e a i E E 133 11 5 5 S tting IP Address sorasininndannn satan a a a a a a a a 133 116 Lead SetiD pices se tacaylansaxtucas ices aaa ea ee E E EE aTa Aa ean 134 ICG Sete Rhythm Lead 1 23 moisir niisniani ii aa a E AE E A E 135 11 62 S tting Lead S quences snien Te a E E E E a a a 136 116 3 Selecting Nebb nysnd ni uhe a R R T a a 136 IL Display amp Sound Set p cenana a E E Glanteaatens 136 MAI Setting Brightness ieena ra a Ria a E A ada es 137 11 7 2 Selecting Display Colors Only for SE 12 Express s sssssssesseseesesseseessesersesseseese 137 11 7 3 Selecting Antialiasing n a en a aa a ys a a a a aa 137 TF ASC tT Key Volume ne een e a a a E N a a 138 W73 Setting Hint VOU Gag 33 yesadceg a a A A A E EEEE AEA RAAE 138
109. int of ST segment Press the function key F3 below Post J to set Post J to 0 20ms 40ms 60ms or 80ms Post J 80ms NOTE J point is the connection point between the end of QRS complex and the start of ST segment It is the standard point to fix the position of ST segment 34 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Please select a proper option based on the patient s actual ECG waves Press the function key F2 below Hold and then the system will not follow the previous settings to change the speed and grade S Hold of the treadmill but keep the current speed and grade until this key is pressed again Press the function key F1 below Patient to open the Patient T Patient Information window It is invalid in the exercise test U ECG waveforms Display real time ECG waveforms V Lead Press the function key F6 below Lead to open the Lead Setup window W Template Button X ST Trend Press the function key F7 below Template and then the 3 lead average templates will be displayed and the Template button will change into the ST Trend button Display 3 lead ST trends Y ST Trend Button Press the function key F7 below ST Trend and then the 3 lead ST trends will be displayed and the ST Trend button will change into the Template button Z Average Template The 3 lead average waves which are updated every 10 seconds and th
110. iograph User Manual About the Electrocardiograph Application Bruce Testing Marry Johnson 1 7 mph Exercise Stage 1 20 30 00 02 20 00 00 40 10 0 7 0 METs Patient Post 60ms 10mm mvV ST on Figure 3 5 Main screen of Template When ID Mode is set to Manual the patient ID is within 30 characters When ID Mode is set to Auto the patient ID is 0 1999 999 A ID 999 When ID Mode is set to Time the patient ID is within 10 characters Patient Name within 60 ASCII characters or the equivalent B Name number of other characters that can be supported by equivalent memory used by 60 ASCII characters HR Overrange Sys Overrange Dia Overrange Battery C Hint Information Weak No Paper Paper Error Hint Information2 DEMO Module Error Lead X Off Overload E Current Protocol The selected protocol name No Testing Testing Testing Stop F Hint Information3 During the exercise test the count from 0 to 9 is displayed after the 121d key on the keyboard is pressed Current Phase and Stage The current phase and stage of the exercise test 2332 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Total Time and Stage Time The left number is the total time which is counted from the beginning of the pretest phase to the end of the exercise test The right number is the stage time which shows the running time of
111. ion Measure Information Diagnosis Information Report Confirmed by 02 06 2010 16 53 52 Current Date and Current Time 3x4 1R ECG waves 0 67 100Hz 0 67Hz DFT Filter 100Hz Lowpass Filter ACS50 50Hz AC Filter 25mm s Paper Speed 10mm mV Gain 4 2 5s 1r 12 leads are printed in 4 groups of 3 and every group is printed for about 2 5s with one rhythm lead at the bottom simultaneously 81 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Institution Name SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm Version Number NOTE Please refer to Section 8 6 1 1 for the explanation of the patient information measure information and diagnosis information 8 6 2 ECG Reports in the Rhythm Mode 02 06 2010 16 54 43 985 ID 001 Age 25 Years Name Marry Johnson 00 00 060 eR aE ieee 4 1 Se SE ess v La Se e P J 1 i 1 a ar J SS gS elo Pgs EL dem AEA ater eel 00 10 60 It j x J ae a ii L J vi A t A ys e p i j j j j j f a 0 67 100Hz ACSO 25mm s 10mm mV Institution Name SE 12Express V1 8 SEMIP V1 5 The above figure shows an ECG report in the rhythm mode and Rhythm Style is set to Three Leads 02 06 2010 16 54 43 Current Date amp Current Time ID 001 Patient ID Age 25 Years Patient Age Name Marry Johnson Patient Name 00 00 00
112. ion and storage SE 12 Series Electrocardiograph User Manual Safety Guidance CAUTION 2 Do not use the equipment in a dusty environment with bad ventilation or in the presence of corrosive 3 Make sure that there is no intense electromagnetic interference source around the equipment such as radio transmitters or mobile phones etc Attention large medical electrical equipment such as electrosurgical equipment radiological equipment and magnetic resonance imaging equipment etc is likely to bring electromagnetic interference 4 Ruptured fuse must only be replaced with that of the same type and rating as the original 5 The device and accessories are to be disposed of according to local regulations after their useful lives Alternatively they can be returned to the dealer or the manufacturer for recycling or proper disposal Batteries are hazardous waste Do NOT dispose of them together with house hold garbage At the end of their lives hand the batteries over to the applicable collection points for the recycling of waste batteries For more detailed information about recycling of this product or battery please contact your local Civic Office or the shop where you purchased the product 6 Federal U S law restricts this device to sale by or on the order of a physician 1 2 4 Preparation and Operation Warnings for SE 12 Express Exercise ECG WARNING 1 Ensure that the main unit and the treadmill ergometer are effectively gro
113. isposable electrodes to the electrode positions on the body surface 4 Clip the disposable electrodes with the alligator clips The quality of ECG waveform will be affected by the contact resistance between the patient and the electrode In order to get a high quality ECG the skin electrode resistance must be minimized while connecting electrodes WARNING 1 Make sure that all electrodes are connected to the patient correctly before operation 2 Ensure that the conductive parts of electrodes and associated connectors including neutral electrodes do not come in contact with earth or any other conducting objects 59s SE 12 Series Electrocardiograph User Manual Operation Preparations 4 6 Attaching Electrodes to the Patient for Exercise ECG The identifiers and color codes of electrodes used comply with IEC EN requirements In order to avoid incorrect connections the electrode identifiers and color codes are specified in Table 4 2 Moreover the equivalent codes according to American requirements are given in Table 4 2 too IEC AHA 7 er 1 2 V1 V2 v3 V4 V5 V6 N RL LL Table 4 2 Electrodes and Their Identifiers and Color Codes European American Electrodes Color Code Electrodes Color Code R Red RA White L Yellow LA Black N or RF Black RL Green F Green LL Red Cl White Red v1 Brown Red C2 White Yellow V2 Brown Yellow C3 White Green V3 Brown Green
114. key F4 below Select to select the file and display the File Manager screen2 112 SE 12 Series Electrocardiograph User Manual Managing Files 3 Press the function key F6 below Preview to open the file preview screen To Preview the File 1 Press the function key F1 below Waveform to display the waveform screen Marry Johnson Ailes i ae Ce eee e E S ers es Sener gt a i ha An A S pand mA A i A l fare A Se eee rege eee a e eee e eee oe eo a i e eE AN anA Ie a E OE EES Pre i i i ph ora ll or ee eg ne eg Og S re j C a S f x rN ph Waveform Template Measure Diagnosis Record Return 2 Press the function key F2 below Template to display the template screen 001 Marry Johnson v6 H Waveform Template Measure _ _Diagnosis_ __Record_ 3 Press the function key F3 below Measure to display the measure screen which shows Patient Name Patient ID Heart Rate P Duration PR interval QRS Duration QT QTC interval P QRS T axis RV5 SV1 amplitude RV5 SV1 amplitude and RV6 SV2 amplitude 113 SE 12 Series Electrocardiograph User Manual Managing Files Marry Johnson Measurement Information HR 60 BPM P Dur 92 ms PR int 174 ms QRS Dur 82 ms QT QTC int 350 350 ms P QRS T axis 51 44 52 o RV5 SV1 amp 1 085 0 552 mV RV5 SV1 amp 1 637 mv RV6 SV2 amp 0 774 0 914 mV Waveform Template Diagnosis R
115. ks should be performed at least every 12 months by a qualified person who has adequate training knowledge and practical experience to perform these tests 1 Inspect the equipment and accessories for mechanical and functional damage 2 Inspect the safety related labels for legibility 3 Inspect the fuse to verify compliance with the rated current and circuit breaking characteristics 4 Verify that the device functions properly as described in the instructions for use 5 Test the protection earth resistance according to IEC EN 60601 1 Limit 0 lohm 6 Test the earth leakage current according to IEC EN UL 60601 1 Limit NC SFC 300A 7 Test the enclosure leakage current according to IEC EN UL 60601 1 Limit NC 100A SFC 300nA 181 SE 12 Series Electrocardiograph User Manual Cleaning Care and Maintenance 8 Test the patient leakage current according to IEC EN 60601 1 Limit NC a c 10uA d c 10pnA SFC a c 50uA d c 50uA 9 Test the patient auxiliary current according to IEC EN 60601 1 Limit NC a c 10uA d c 10A SFC a c SOWA d c 50uA 10 Test the patient leakage current under single fault condition with mains voltage on the applied part according to IEC EN 60601 1 Limit 50uA CF The leakage current should never exceed the limit The data should be recorded in an equipment log If the device is not functioning properly or fails any of the above tests the device has to be repaired WARNING
116. l chest electrodes in the same way NOTE Long time measurement with a strong negative pressure on the suction bulb may cause reddening of the skin When using the electrode on small children or patients with delicate skin squeeze the suction ball lightly Limb Electrode Connection 1 2 3 4 5 6 7 Ensure that the electrodes are clean Align all lead wires of the patient cable to avoid twisting and connect the lead wires to the corresponding electrodes according to the colors and identifiers Clean the electrode area which is a short distance above the ankle or the wrist with 75 alcohol Daub the electrode area on the limb with gel evenly Place a small amount of gel on the metal part of the limb electrode clamp Connect the electrode to the limb and make sure that the metal part is placed on the electrode area above the ankle or the wrist Attach all limb electrodes in the same way 51 SE 12 Series Electrocardiograph User Manual Operation Preparations 4 5 2 2 Disposable Electrodes CAUTION The disposable electrodes can only be used for one time Disposable Electrode Alligator Clip a Disposable electrodes must be used together with alligator clips Disposable Electrode Connection 1 Align all lead wires of the patient cable to avoid twisting and connect the alligator clips to the lead wires 2 Clean the electrode areas on the body surface with 75 alcohol 3 Attach the d
117. lly during the exercise test You can set the start time to print the first recovery report by filling in the Start Time textbox For example if you fill 10 in the Start Time textbox the first recovery report will be printed out 10s after entering the recovery phase You can set the interval to print the later recovery reports in the Interval pull down list For example if you select 1 min in the Interval pull down list the later recovery reports will be printed out every 1 min 3 Report Style When Report Style is set to 3x4 1 ECG waves of 12 leads are printed in 4 groups of 3 with the ECG wave of one rhythm lead on the bottom of the ECG reports When Report Style is set to 6x2 1 ECG waves of 12 leads are printed in 2 groups of 6 with the ECG wave of one rhythm lead on the bottom of the ECG reports 169 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional 4 Final Report You can select Summary Report ST Scope Report Trend Graph Report and Edit Conclusion as the final reports After an exercise test is terminated you can press the START STOP key on the keyboard to print out the selected final reports NOTE Pressing the START STOP key during the printing course can stop printing 12 4 3 Protocol Manager Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Protocol on the System Setup screen press to open the Protocol Manager
118. lowed to be used within the patient vicinity 1 5m 6ft Do not exceed the maximum permitted load when using multiple portable socket outlets to supply the system SE 12 Series Electrocardiograph User Manual Safety Guidance 26 27 28 29 30 31 32 WARNING Multiple portable socket outlets shall not be placed on the floor Do not use the additional multiple portable socket outlet or extension cord in the medical electrical system unless it s specified as part of the system by manufacturer And the multiple portable socket outlets provided with the system shall only be used for supplying power to equipment which is intended to form part of the system Accessory equipment connected to the analog and digital interfaces must be certified according to the respective IEC EN standards e g IEC EN 60950 for data processing equipment and IEC EN 60601 1 for medical equipment Furthermore all configurations shall comply with the valid version of the standard IEC EN 60601 1 1 Therefore anybody who connects additional equipment to the signal input or output connector to configure a medical system must make sure that it complies with the requirements of the valid version of the system standard IEC EN 60601 1 1 If in doubt consult our technical service department or your local distributor Parts and accessories used must meet the requirements of the applicable IEC EN 601 series safety standards and or the system configuratio
119. ly 12 channel waves are displayed and recorded simultaneously High resolution thermal recorder recording frequency response lt 150Hz Supporting external USB printer 24 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Flexible printing formats The auto manual rhythm R R analysis and off modes can be chosen freely Automatic baseline adjustment for optimal printing Convenient operation of system setup and file management Multiple file formats DAT SCP FDA XML PDF Measurement function and interpretation function Hint information of lead off lack of paper low battery capacity etc Supporting bar code reader ECG data can be transmitted to the PC software through the serial cable net cable or wireless AP optional Real time transmission to PC ECG The following features are only for the exercise test function of SE 12 Express optional Real time analysis ST segment and trend are applied while sampling Real time display and print of 12 lead simultaneous ECG waveforms ST segment analysis while sampling ST position is adjustable while sampling Providing average templates of three rhythm leads in every stage to observe the change of ST segments between every two stages Automatically forming elaborate reports including Summary Report ST Scope Report and Trend Graph Report Providing classical exercise protocols exercise proto
120. minant beat from lead V2 Diagnosis Information Diagnosis information shows the auto diagnosis result 80 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Average Template Average template shows the average value of 10s sampled ECG signals of every lead The broken lines on the template are position markers They respectively mark the start and end points of the P and QRS waves and the end point of the T wave 8 6 1 2 Example of 3x4 1R 02 06 2010 16 53 52 g8 ID 001 HR 60 BPM Diagnosis Information Name Marry Johnson P Dur gt 94 ms 800 Sinus Rhythm Age 25 Years Gender Female PR int 170 ms Normal ECG Height 165 cm Weight 50 kg QRS Dur 82 ms Room No 0023 QT QTC int 355 355 ms Department P QRS T axis gt 5 45 54 RVS SV1 amp 1 042 0 533 mV RVS SV1 amp 1 575 mV RV6 SV2 amp 0 739 0 879 mV Report Confirmed by f aV r ral L To E TEA EED Eg aVR pap ats N E KS of ee ES OD A 9 Se eS j t 1 Uh i i avh A y i 4 A XSA et i i i lL i j ave NELAS ILA ee V6 Mei SN ip 6 a el e i eas ey RAV et eee fe aj E A n PAV Aih ee 0 67 100Hz ACSO 25mm s 10mm mY 4 2 5s 1r_tnstitution Name SE 12Express V1 8 SEMIP VLS The above figure shows an ECG report in the auto mode The style is 3x4 1R The ECG report includes Patient Informat
121. n 62 Saving Path ECG 63 File Format DAT 64 Delete After Trans Or Export Off 65 Replace When Memory Full Off 66 SCP File Compression On 67 System Password Cleared 68 Caps Lock Off 69 Pacemaker Detection Sensitivity Low Exercise ECG 1 Display Style 4x3 2 Speed Unit mph 3 Post J 60ms 4 Device Type Treadmill 5 Device Model TM400 M 6 Ergometer Ergoline 7 BP Monitor In Ergometer 8 Maximum Systole 220mmHg 9 Maximum Diastole 90 mmHg 10 Minimum Systole 110 mmHg 11 Minimum Diastole 60 mmHg 147 SE 12 Series Electrocardiograph User Manual System Setup 12 Max Predicted HR 220 13 The proportion of Target HR in Max 85 Predicted HR 14 AC Filter On 15 DFT Filter 0 67Hz 16 EMG Filter Off 17 Lowpass Filter 100Hz 18 Rhythm Lead 1 II 19 Rhythm Lead 2 Vi 20 Rhythm Lead 3 V5 21 Lead Sequence Standard 22 Gain 10mm mV 23 Paper Marker Yes 24 Exercise Report Late Stage 25 Report Style 6x2 1 26 Recovery Report On 21 Start time of Recovery Report 10s 28 Interval of Recovery Report 2min 29 Summary Report On 30 ST Scope Report On 31 Trend Graph Report On 32 Edit Conclusion On Table 11 2 System Setup Defaults only in the U S Resting ECG Setup Default 1 Mode Options Auto Manual Rhythm OFF R R 2 Manual Style 6 channels 3 Auto Display Style 3x4 1 4 Rhythm Style Three Leads 148 SE 12 Series Electrocardiograph Use
122. n must meet the requirements of the IEC EN 60601 1 1 medical electrical systems standard Connecting any accessory such as external printer or other device such as the computer to this electrocardiograph makes a medical system In that case additional safety measures should be taken during installation of the system and the system shall provide a Within the patient environment a level of safety comparable to that provided by medical electrical equipment complying with IEC EN 60601 1 and b Outside the patient environment the level of safety appropriate for non medical electrical equipment complying with other IEC or ISO safety standards If multiple instruments are connected to a patient the sum of the leakage currents may exceed the limits given in the IEC EN 60601 1 and may pose a safety hazard Consult your service personnel The potential equalization bar can be connected to that of other equipment when necessary Make sure that all these devices are connected to the potential equalization terminal SE 12 Series Electrocardiograph User Manual Safety Guidance 1 2 2 Li ion Battery Care Warnings WARNING Improper operation may cause the internal li ion battery hereinafter called battery to be hot ignited or exploded and it may lead to the decrease of the battery capacity It is necessary to read the user manual carefully and pay more attention to warning messages Only qualified service engineers authorized by the ma
123. n the Patient Information window 11 4 2 Selecting ID Mode Press Tab or Shift Tab to move the cursor to ID Mode in the Patient Information Setup window and then press the Up or Down arrow to select a mode 128 SE 12 Series Electrocardiograph User Manual System Setup You can set ID Mode to Auto Time or Manual When ID Mode is set to Auto the patient ID can be automatically generated The patient ID range is 0 1999 999 999 When ID Mode is set to Time the patient ID can be automatically generated according to the time when you press the START STOP key to print an ECG report When ID Mode is set to Manual you can enter the patient ID manually in the Patient Information window Only 30 ASCII characters can be input 11 4 3 Selecting ID Hint Press Tab or Shift Tab to move the cursor to ID Hint in the Patient Information Setup window and then press the Up or Down arrow to select On or Off In the auto rhythm or off mode when ID Mode is set to Manual and ID Hint is set to On if you do not input the patient ID before pressing the START STOP key a hint will pop up to remind you to input the patient ID 11 4 4 Setting Prompt Press Tab or Shift Tab to move the cursor to Prompt in the Patient Information Setup window and then press the Up or Down arrow to select Confirmed By or Unconfirmed When Prompt is set to Confirmed By if Physician is selected and the physician name is input in the Patient Inform
124. nd performance of the equipment if Assembly operations extensions re adjustments modifications or repairs are carried out by persons authorized by EDAN and The electrical installation of the relevant room complies with national standards and The instrument is used in accordance with the instructions for use Upon request EDAN may provide with compensation necessary circuit diagrams and other information to help qualified technician to maintain and repair some parts which EDAN may define as user serviceable Terms Used in this Manual This guide is designed to give key concepts on safety precautions WARNING A WARNING label advises against certain actions or situations that could result in personal injury or death CAUTION A CAUTION label advises against actions or situations that could damage equipment produce inaccurate data or invalidate a procedure NOTE A NOTE provides useful information regarding a function or a procedure II Table of Contents Chapter T Safety Guidance scescisicevess ccalecsxnccsstpnsctsasescceesscetoetiensiea ean isan ee Ones aan 1 VA Iptended W Se ccc sta suscatucta ss eb a a a a tam dau eaees l 1 2 Warnings and Cautions iiss issn Sena iee n ta Aa aw a Ae a eee i ae 1 TaD Safety Warmin oS rcon tch ins andere e EE T N a T ae weuasuaceneeels 2 1 2 2 Li ion Battery Care Warnings essssessessesseessessessrossessresseesesersstessesetsstessesstesresseeseeseessee 5 123 Gen ral C
125. nect the electrocardiograph to the treadmill RS232 port RS232 port Connect the RS232 port of the treadmill to the RS232 port of the electrocardiograph with an RS232 cable NOTE The position of the RS232 port may be different on different treadmills 158 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional 2 Connect the electrocardiograph to the ergometer RS232 port Connect the RS232 in port of the ergometer to the RS232 port of the electrocardiograph with an RS232 cable NOTE The position of the RS232 in port may be different on different ergometers 3 Connect the electrocardiograph to the stress BP monitor D A 4 Connect the power cords and connect the earth wire when necessary 5 Load the recorder paper 159 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional 6 Turn on the stress BP monitor and treadmill ergometer 7 Set the electrocardiograph 1 After turning on the electrocardiograph press Pretest on the keyboard to open the main screen of the exercise test 2 Press the function key F6 below Setup to open the System Setup screen 3 Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on General Info on the System Setup screen press to open the General Information Setup window System Setup 4 Set Device Type Device Mode and B
126. nfect the chest and limb electrodes after each use CAUTION 1 Do not use high temperature high pressure vapour or ionizing radiation as disinfection methods 2 Do not use chloric disinfectant such as chloride sodium hypochlorite etc 178 SE 12 Series Electrocardiograph User Manual Cleaning Care and Maintenance 15 3 Care and Maintenance CAUTION Operate the electrocardiograph charge the battery and store the battery at a temperature of 40 C 104 F or lower Exposure to higher or lower temperature may reduce battery life damage the battery and degrade overall electrocardiograph performance 15 3 1 Recharge and Replacement of Battery 1 Capacity Identification The current capacity of the battery can be identified according to the battery symbol in the top right corner of the LCD screen C Full capacity CE 23 capacity Cad 1 3 capacity Empty 2 Recharge The 12 channel electrocardiograph is equipped with the recharge control circuit together with battery When the unit is connected to the mains supply the battery will be recharged automatically Then the battery recharging indicator gt L and the mains supply indicator 0 will be lit at the same time During the recharging course the symbol Lod flashes in the top right corner of the LCD screen After the battery is fully recharged the symbol stops flashing and the battery recharging indicator gt is black Because of the capacity cons
127. ng equipment and IEC EN 60601 1 for medical equipment Furthermore all configurations shall comply with the valid version of the standard IEC EN 60601 1 1 Therefore anybody who connects additional equipment to the signal input or output connector to configure a medical system must make sure that it complies with the requirements of the valid version of the system standard IEC EN 60601 1 1 If in doubt consult our technical service department or your local distributor 2 If multiple instruments are connected to a patient the sum of the leakage currents may exceed the limits given in the IEC EN 60601 1 and may pose a safety hazard Consult your service personnel 2 6 Bottom Panel C D B E A Figure 2 11 SE 12 Express Bottom Panel 22 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application C D B E A Figure 2 12 SE 12 Bottom Panel Name Explanation A Speaker Hole Path for sound from speaker B Battery Compartment Compartment for battery C Fuse The specification is T1AL250VP 5x20 D Heat Emission Hole Path for internal heat emission E Label Position for product information label 1 Battery Compartment The rated voltage and the rated capacity of the battery pack are as follows SE 12 Express Rated Voltage 14 8V Rated Capacity 4400mAh SE 12 Rated Voltage 14 8V Rated Capacity 2200mAh WARNING 1 Improper operation may cause the battery t
128. nly for SE 12 Express Press Tab or Shift Tab to move the cursor to the Display Colors list box in the Display amp Sound Setup window and then press the Up or Down arrow to highlight Monochrome Option1 or Option2 11 7 3 Selecting Antialiasing Press Tab or Shift Tab to move the cursor to the Antialiasing list box in the Display amp Sound Setup window and then press the Up or Down arrow to highlight Off or On When Antialiasing is set to On the system will automatically make the waveform smooth When Antialiasing is set to Off the system will not make the waveform smooth 137 SE 12 Series Electrocardiograph User Manual System Setup 11 7 4 Setting Key Volume Press Tab or Shift Tab to move the cursor to the Key Volume list box in the Display amp Sound Setup window and then press the Up or Down arrow to highlight an option When you press keys on the keyboard the electrocardiograph gives a short sound You can set Key Volume to Low Medium High or Off When it is set to Off there is no sound when you press keys 11 7 5 Setting Hint Volume Press Tab or Shift Tab to move the cursor to the Hint Volume list box in the Display amp Sound Setup window and then press the Up or Down arrow to highlight an option When the electrocardiograph displays a hint such as Lead Off Overload Battery Weak etc there is a sound You can set Hint Volume to Low Medium High or Off When it is set to Off there is no hint sound
129. nnect the electrocardiograph to the network of the PC with an Ethernet cable recommended by the manufacturer If the wireless AP transmission is used connect the PC to the server wireless AP and connect the electrocardiograph to the client wireless AP Only the wireless AP recommended by the manufacturer can be used NOTE 1 For details on configuring the wireless AP please refer to the user manual delivered with the wireless AP 2 There should be no shield in or around the room where the wireless AP is used or else the wireless transmission may fail 2 Log into the Smart ECG Viewer software NOTE If you don t connect the electrocardiograph to the network of the PC or if you don t connect the electrocardiograph PC to the wireless AP or you do not log into Smart ECG Viewer before transmission the following hint will pop up HINT Please check Net cable connection and PC software 3 Set Transmission Mode to Ethernet in the Transmission Setup window Set the IP addresses For details on setting the transmission mode and the IP addresses please see Section 9 1 2 Transmitting ECG Data in DAT Format Through Net Cable 4 Press the function key F7 below File to display the File Manager screen1 5 Press the function key F1 below Trans All to transmit all the files to the PC After all the files are transmitted the following hint will pop up 106 SE 12 Series Electrocardiograph User Manual Mana
130. nufacturer can open the battery compartment and replace the battery and batteries of the same model and specification should be used DANGER OF EXPLOSION Do not reverse the anode and the cathode when installing the battery Do not heat or splash the battery or throw it into fire or water Do not destroy the battery do not pierce battery with a sharp object such as a needle do not hit with a hammer step on or throw or drop to cause strong shock do not disassemble or modify the battery When leakage or foul smell is found stop using the battery immediately If your skin or cloth comes into contact with the leakage liquid cleanse it with clean water at once If the leakage liquid splashes into your eyes do not wipe them Irrigate them with clean water first and go to see a doctor immediately Properly dispose of or recycle the depleted battery according to local regulations Only when the device is off can the battery be installed or removed Remove the battery from the electrocardiograph when the electrocardiograph is not used for a long time If the battery is stored alone and not used for a long time we recommend that the battery should be charged at least once every 6 months to prevent overdischarge 1 2 3 General Cautions 1 CAUTION Avoid liquid splash and excessive temperature The temperature must be kept between 5 C and 40 C during operation and it should be kept between 20 C and 55 C during transportat
131. o be hot ignited or exploded and it may lead to the decrease of the battery capacity Therefore it is necessary to read the user manual carefully and pay more attention to warning messages 93 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application WARNING 2 When leakage or foul smell is found stop using the battery immediately If your skin or cloth comes into contact with the leakage liquid cleanse it with clean water at once If the leakage liquid splashes into your eyes do not wipe them Irrigate them with clean water first and go to see a doctor immediately 3 Only qualified service engineers authorized by the manufacturer can open the battery compartment and replace the battery and batteries of the same model and specification must be used 4 Only when the device is off can the battery be installed or removed NOTE If the battery has not been used for two months or more you should recharge it before using it again 2 Fuse There are two fuses of the same specification installed on the bottom of the main unit The specification is T1LAL250VP 05x20 WARNING Ruptured fuses must only be replaced with those of the same type and rating as the original 2 7 Function Features Supporting multi language Full alphanumeric keyboard For SE 12 Express touch screen is available Battery with large capacity ECG signals of 12 leads are gathered and amplified simultaneous
132. o set File Format to SCP FDA XML PDF first activate the SCP FDA XML PDF function on the Advanced Setup screen For details on activating the SCP FDA XML PDF function please refer to Section 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format Through Net Cable 11 9 4 Selecting Deleting Files After Transmission or Export Press Tab or Shift Tab to move the cursor to Delete After Trans Or Export in the File Setup window and then press the Up or Down arrow to highlight Off or On When Delete After Trans Or Export is set to On the files will be automatically deleted from the File Manager screen after they are transmitted to the PC or exported to the U disk 11 9 5 Selecting Replacing When Memory is Full Press Tab or Shift Tab to move the cursor to Replace When Memory Full in the File Setup window and then press the Up or Down arrow to highlight Off or On When Replace When Memory Full is set to On if there is no space on the memory the files will replace the earliest ones automatically 11 9 6 Selecting SCP File Compression Press Tab or Shift Tab to move the cursor to SCP File Compression in the File Setup window and then press the Up or Down arrow to highlight On or Off If SCP File Compression is set to On the SCP file will be compressed After the SCP function is activated SCP File Compression appears in the File Setup window For details on activating the SCP function please refer to Section 9 1 3 Transmitting E
133. olled Paper 1 Press the casing button downwards and remove the casing to open the recorder 2 Take out the paper roller and remove remainder paper from the roller if necessary 3 Take off the wrapper of the new thermal paper roll and then put the paper roll through the roller 44 SE 12 Series Electrocardiograph User Manual Operation Preparations 4 Place the paper and the roller gently in the recorder with the roller pin clicking into the groove Groove 5 Pull the paper out with the grid side facing the thermal print head and replace the casing on the recorder 6 Press down the recorder casing firmly 7 To select Paper Marker Press on the keyboard to turn on the unit After the main screen is displayed press the function key F6 below Setup to display the System Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Record Info on the System Setup screen press to open the Record Info Setup window Press Tab or Shift Tab to move the cursor to the Paper Marker list box and then press the Up or Down arrow to highlight No Press to confirm and then the System Setup screen appears Press ESC to return to the main screen 45 SE 12 Series Electrocardiograph User Manual Operation Preparations 8 Advance the recorder paper Tab O When the main screen is displayed you can press to advance the paper for Tab O
134. omatically Chapter 9 _ Transmitting ECG Data Automatically 9 1 Transmitting ECG Data to the PC NOTE 1 To transmit ECG data in DAT format to the PC the Smart ECG Viewer software of the manufacturer must be installed in the PC You should log into the Smart ECG Viewer software before transmission 2 To transmit ECG data in SCP FDA XML PDF format to the PC the FTP receiving software must be installed in the PC You should log into the FTP receiving software before transmission 3 By default the ECG file format is DAT You can activate SCP FDA XML PDF function on the Advanced Setup screen For details refer to Section 9 1 3 Transmitting ECG Data in SCP FDA XML PDF Format Through Net Cable 9 1 1 Transmitting ECG Data in DAT Format through Serial Cable 1 Connect the RS232 socket of the PC to the RS232 socket of the electrocardiograph with an RS232 cable 2 Or if the PC has no RS232 socket connect the USB socket of the PC to the RS232 socket of the electrocardiograph by using the RS232 USB assembly 92 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Automatically Figure 9 1 RS232 USB Assembly 3 Set Auto Transmission to On and Transmission Mode to UART in the Transmission Setup window 1 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen 2 Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to
135. omatically at the same time Both the mains supply indicator o and the battery recharging indicator st will be lit 40 SE 12 Series Electrocardiograph User Manual Operation Preparations Battery When the battery is used turn on the unit by pressing Q on the keyboard Then the battery indicator ta will be lit and the battery symbol will be displayed on the LCD screen Because of the consumption during the storage and transport course the battery capacity may not be full If the symbol m and the hint information Battery Weak are displayed which means the battery capacity is low please recharge the battery first CAUTION 1 If the electrocardiograph is turned off automatically because of low battery capacity the settings may not be saved 2 If the battery has been fully charged and requires recharging after printing only a few ECGs consider replacement 3 The use of electrocardiograph accessories such as barcode reader will deplete battery power at a faster rate The battery will require more frequent charging if these accessories are used with the electrocardiograph When the battery is fully charged SE 12 can work normally about 4 hours and print about 300 ECG reports of 3x4 1R in the auto mode SE 12 Express can work normally about 5 hours and print about 350 ECG reports of 3x4 1R in the auto mode Please refer to the maintenance section for how to recharge the battery When the battery is being
136. ons equipment should be used no closer to any part of the 12 channel electrocardiograph including cables than the recommended separation distance Conducted RF 3 Vims 3V ims IEC EN 150 kHz to 80 MHz calculated from the equation applicable 61000 4 6 to the frequency of the transmitter Recommended separation distance 3 V m 3 V m d 1 2VP Radiated RF 80 MHz to 2 5 GHz CHEN d 1 2P 80 MHz to 800 MHz 61000 4 3 d 23 VP 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W the transmitter and d is the recommended separation distance in according to manufacturer metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be 193 SE 12 Series Electrocardiograph User Manual EMC Information less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol C NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy
137. or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Press the function key F5 below Delete to display the following hint press Tab or Shift Tab to move the cursor to the OK button and then press to delete the selected file from the electrocardiograph 109 SE 12 Series Electrocardiograph User Manual Managing Files HINT Cancel 10 4 Searching Files To Open the SearchInfo Setup Window 1 When the main screen is displayed press the function key F7 below File to open the File Manager screen 1 2 Press the function key F5 below Search to open the SearchInfo Setup window SearchInfo Setup PT a PONS 20 a To Search Files 1 Press Tab Shift Tab or the Up or Down arrow to select Name and then input the patient name Press or press Tab or Shift Tab to move the cursor to the OK button and then press e Then all the files with the input patient name will be displayed on the File Manager screen 1 2 Press Tab Shift Tab or the Up or Down arrow to select ID and then input the patient ID Press E or press Tab or Shift Tab to move the cursor to the OK button and then press ca Then all the files with the input patient ID will be displayed on the File Manager screen 1 110 SE 12 Series Electrocardiograph User Manual Managing Files 3 Press Tab Shift Tab o
138. or else the wireless transmission may fail 2 Set Auto Transmission to On and Transmission Mode to Ethernet in the Transmission Setup window Set the IP addresses 1 2 3 4 5 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to Transmission press to open the Transmission Setup window Press Tab or Shift Tab to move the cursor to the Auto Transmission list box and then press the Up or Down arrow to select On Press Tab or Shift Tab to move the cursor to the Transmission Mode list box and then press the Up or Down arrow to select Ethernet Press Tab or Shift Tab to move the cursor to the Server IP item Set the Server IP item to the IP of the PC 94 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Automatically 6 Press Tab or Shift Tab to move the cursor to the Local IP item For the cross network transmission set the first two sections of the Local IP item to the first two sections of the IP of the PC Set the third section of the Local IP item to the network segment of the electrocardiograph which depends on the configuration of Router The last section of the Local IP item can be set at random For the same network transmission set the first three sections of the Local IP item to the first three sections of the IP of the PC The last sec
139. ormation Guidance and manufacture s declaration electromagnetic immunity for all EQUIPMENT and SYSTEMS Guidance and manufacture s declaration electromagnetic immunity The 12 channel electrocardiograph is intended for use in the electromagnetic environment specified below The customer or the user of 12 channel electrocardiograph should assure that it is used in such an environment Immunity test IEC EN 60601 test level Compliance level Electromagnetic environment guidance Electrostatic 6 kV contact 6 kV contact Floors should be wood discharge ESD concrete or ceramic tile If 8 kV air 8 kV air Al d with oor are covere i IEC EN 61000 4 2 E i synthetic material the relative humidity should be at least 30 Electrical fast 2 kV for power 2 kV for power Mains power quality transient burst supply lines supply lines should be that of a typical IEC EN 61000 4 4 commerhial or hospital environment Surge 1 kV line to line 1 kV line to line Mains power quality hould be that of a typical IEC EN 61000 4 5 2 kV line to 2 kV line to Sn te ae he ee commercial or hospital ground ground i environment Power frequency 3A m 3A m Power frequency magnetic 50Hz 60Hz fields should be at revels characteristic of a typical magnetic field location in a typical IEC EN 61000 4 8 copier or hospital environment Voltage dips short lt 5 Ur lt 5 Ur Mains power quality interruptions
140. p Standard ok Cabrera Figure 11 8 Lead Setup window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 6 1 Setting Rhythm Lead1 2 3 Press Tab or Shift Tab to move the cursor to the Rhythm Lead1 2 3 list box in the Lead Setup window and then press the Up or Down arrow to highlight an option The rhythm lead can be one of 12 standard leads I II II aVR aVL aVF V1 V2 V3 V4 V5 or V6 In the auto mode when Record Style is set to 3x4 1R or 6x2 1R the rhythm lead selected in the Rhythm Lead1 list box will be printed in the ECG reports when Record Style is set to 3x4 3R 3 rhythm leads selected respectively in the Rhythm Lead1 2 3 list box will be printed in the ECG reports In the rhythm mode when Rhythm Style is set to Single Lead 60s wave of the rhythm lead selected in the Rhythm Lead1 list box will be printed in the ECG reports when Rhythm Style is set to Three Leads 20s waves of three rhythm leads selected respectively in the Rhythm Lead1 2 3 list box will be printed in the ECG reports 135 SE 12 Series Electrocardiograph User Manual System Setup In the R R analysis mode the R R analysis report of the rhythm lead selected in the Rhythm Lead1 list box will be printed 11 6 2 Setting Lead Sequence Press Tab or Shift Tab to move the cursor to the Lead Sequence list box in the Le
141. pital uses The 12 channel electrocardiograph has two models SE 12 and SE 12 Express SE 12 adopts 320240 dot single color LCD screen SE 12 Express adopts 800600 multicolor LCD screen Configuration main unit power cord patient cable chest electrodes limb electrodes disposable electrodes alligator clips thermal recorder paper fuses battery NOTE The pictures and windows in this manual are for reference only ll SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application 2 1 Top Panel Indicators LCD Screen Oocgocooo COOSSSSOSS COCO O CS oooooooopnonpoo pDopooooooooo ooouguoD0Da ovoooooooo Doca oO aaao x Recorder Keyboard Figure 2 1 SE 12 Express Indicators LCD Screen Recorder Stat ahaha ta ee ooooooooooo0o oooooooooooo0 oooooooocon ooocoooooc Doca o 000 _ Keyboard Figure 2 2 SE 12 12 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application 2 2 Keyboard and Keys Cy J a Ls HOOMBWOWBOHWOUWONOUS A w o o a A w U o CS E3 E3 b3 t O 7 i Hoilola oin nnne Figure 2 3 SE 12 Express Keyboard CJ E amp ee c O o U a a a A o o o U O a BMOHWOWUOOWHWUU G 6 b5 E E e a O i H KRW O A a W w U O e i te E SK 4 Figure 2 4 SE 12 Keyboard 13 SE 12 Series
142. r Manual System Setup 5 Sampling Mode Real time Sample 6 Duration Periodic Sample 60 min 7 Interval Periodic Sample 1 min 8 Preview Off 9 Auto Extend Record Off 10 AC filter On 11 EMG filter Off 12 DFT filter 0 67Hz 13 Lowpass filter 100Hz 14 Record Style 3x4 1 15 Record Mode Save Paper 16 Record Sequence Sequential 17 Gain 10mm mV 18 Record Device Thermal 19 Speed 25mm s 20 Paper Marker Yes 21 Sample Time 10s 22 Patient Information On 23 Template On 24 Position Marker On 25 Measure On 26 Analysis On 27 Minnesota Code Off 28 Baseline Adjustment Horizontal 29 R R Histogram On 30 R R Interval List On 31 R R Waveform On 32 Grid of Thermal Report Off 33 Grid of USB Report On 149 SE 12 Series Electrocardiograph User Manual System Setup 150 34 Gender Height Weight D O B On First Last Name BP Race 35 Pacemaker Medication Boom No off Department Physician Technician Ref Physician 36 ID Hint On 37 Next Patient Off 38 ID Mode Manual 39 Patient Information Cleared After Recording 40 H W Unit inch lb 41 BP Unit mmHg 42 Prompt Confirmed By 43 User Defined Cleared 44 Auto Transmission Off 45 Transmission Mode Ethernet 46 FTP User Name FTP Password FTP Cleared Path 47 Lead Sequence Standard 48 Nehb Off 49
143. r press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 1 1 Selecting Work Mode Press Tab or Shift Tab to move the cursor to a work mode press Spacebar to select it and then a check mark V appears in the box before the work mode NOTE Only if a work mode is selected in the Work Mode Setup window can the work mode be selected by pressing the MODE key when the main screen is displayed MANU In the manual mode you can determine the lead group to be displayed and printed AUTO In the auto mode the lead groups are switched automatically according to the lead sequence during the printing course After the ECG waves of one lead group are printed within a certain time the system switches to print ECG waves of another lead group automatically RHYT In the rhythm mode you can select rhythm leads to print 60s or 20s rhythm lead ECG waves 116 SE 12 Series Electrocardiograph User Manual System Setup R R In the R R analysis mode you can select a lead to print its R R histogram R R trend chart 180s compressed ECG waveform and all the R R interval values OFF In the off mode the lead groups are switched automatically according to the lead sequence When the main screen is displayed after pressing the START STOP key the sampled ECG data can be saved and transmitted but can not be printed 11 1 2 Selecting Manual Style Press Tab or Shift
144. r the Up or Down arrow to select Time and then input the examination time range Press Ee or press Tab or Shift Tab to move the cursor to the OK button and then press e Then all the corresponding files from the start time to the end time will be displayed on the File Manager screen1 NOTE The time mode is year month day in the Searchlnfo Setup window 10 5 Importing Files 1 Insert the U disk recommended by the manufacturer to USB socket 2 of the electrocardiograph 2 When the main screen is displayed press the function key F7 below File to open the File Manager screen 3 Press the function key F6 below Import to import files from the directory of ECGDATA ECG X Import of the U disk to the electrocardiograph NOTE 1 X can be set in the Device No textbox in the Transmission Setup window 2 Only the ECG files in DAT format produced by the electrocardiograph of the manufacturer can be imported 3 For SE 12 a maximum of 100 files can be imported at one time For SE 12 Express a maximum of 200 files can be imported at one time 10 6 Editing Patient Information When the main screen is displayed press the function key F7 below File to open the File Manager screen1 Press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Press the function key F1 below Edit to open the Patient Information win
145. r to Auto Extend Record in the Work Mode Setup window and then press the Up or Down arrow to highlight Off or On When Auto Extend Record is set to On if arrhythmia is detected in the auto or off mode a hint will pop up to ask you whether to print an extra rhythm report after the 12 lead ECG report 11 2 Filter Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Filter on the System Setup screen press to open the Filter Setup window In the Filter Setup window you can set AC Filter EMG Filter DFT Filter and Lowpass Filter 119 SE 12 Series Electrocardiograph User Manual System Setup Filter Setup On Off EA Cancel Figure 11 3 Filter Setup window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 2 1 Setting AC Filter Press Tab or Shift Tab to move the cursor to the AC Filter list box in the Filter Setup window Press the Up or Down arrow to highlight Off or On AC Filter suppresses AC interference without attenuating or distorting the ECG signals Select On to turn on the function and select Off to turn it off NOTE AC frequency can be set to 50Hz or 60Hz on the Advanced Setup screen according to local mains supply specifications 11 2 2 Setting DFT Filter Press Tab or Shift Tab to move the cursor to the DFT
146. r to the OK button and then press Ce T3 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Lead Setup Standard Cabrera After setup press ESC to return to the main screen When the main screen is displayed press the MODE key to select the rhythm mode Press F3 to select a paper speed Press F4 to switch the gain Press F5 to set the EMG filter or the Lowpass filter Press the START STOP key to begin to count the sampling time When the sampling time reaches 60s in the Single Lead style or 20s in the Three Leads style it begins to print an ECG report It will stop automatically after printing a complete report of rhythm lead ECG waveforms Or press the START STOP key again to stop printing the ECG report 8 4 R R Analysis Mode Operation Method 1 To set Mode Options or Rhythm Lead1 When the main screen is displayed press the function key F6 below Setup to open the System Setup screen The cursor is on Work Mode Press to open the Work Mode Setup window 1 Press Tab or Shift Tab to move the cursor to R R press Spacebar to select it and then a check mark V appears in the box before R R 74 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 2 3 4 5 Work Mode Setup Pre Sample Real time Sample Triggered Sample Periodic Sample sf lt i lt I si Single Lead fn 6 channels Three Leads 12 channels of Ci Press E or pr
147. racy of data 5 x axis 5 y axis HR Recognition Technique Peak peak detection HR Range 30 BPM 300 BPM Accuracy 1 BPM ECG Unit Leads 12 standard leads Acquisition Mode simultaneously 12 leads A D Resolution 24 bits Time Constant gt 3 2s Frequency Response 0 05Hz 150Hz 3dB Gain 2 5 5 10 20 10 5 AGC mm mV Input Impedance gt 50MQ 10Hz Input Circuit Current lt 0 01pA Input Voltage Range lt 5 mVpp 189 SE 12 Series Electrocardiograph User Manual Technical Specifications Calibration Voltage ImV 2 DC Offset Voltage 600mV Noise lt 12 5 uVp p Multichannel crosstalk lt 0 5mm AC Filter On Off DFT Filter 0 05Hz 0 15Hz 0 25Hz 0 32Hz 0 5Hz 0 67Hz Filter EMG Filter 25Hz 35Hz 45Hz OFF LOWPASS Filter 150Hz 100Hz 75Hz CMRR gt 115dB Sampling Frequency 1000 Hz Pacemaker Detection Amplitude 2 to 700 mV Width 0 1 to 2 0 ms Sampling Frequency 10 000 sec channel External Input Output Optional gt 100kQ Sensitivity 10mm V 5 Input Single ended lt 100Q Sensitivity 1V mV 5 Output Single ended NOTE 1 Test the accuracy of input signal reproduction according to the methods described in clause 4 2 7 2 in ANSI AAMI EC11 1991 R 2001 and the result complies with the clause 3 2 7 2 in ANSI AAMI EC11 1991 R 2001 2 Overall System Error is tested
148. ration transducers is not supported and may produce undesired results Disconnect the patient data cable from the electrocardiograph or detach the leads from the patient prior to performing any procedure that uses high frequency surgical equipment If the wireless AP technology is used in order to maintain compliance with the FCC RF exposure guidelines the wireless AP should be installed and operated with a minimum distance of 20cm between the radiator and the human body There should be no shield in or around the room where the wireless AP is used Fix attention on the examination to avoid missing important ECG waves SHOCK HAZARD Don t connect non medical electrical equipment which has been supplied as a part of the system directly to the wall outlet when the non medical equipment is intended to be supplied by a multiple portable socket outlet with an isolation transformer SHOCK HAZARD Don t connect electrical equipment which has not been supplied as a part of the system to the multiple portable socket outlets supplying the system Do not connect any equipment or accessories that are not approved by the manufacturer or that are not IEC EN 60601 1 1 approved to the electrocardiograph The operation or use of non approved equipment or accessories with the electrocardiograph is not tested or supported and electrocardiograph operation and safety are not guaranteed Any non medical equipment such as the external printer is not al
149. re 12 1 System Setup screen for Exercise Test After setup 1 Press ESC to return to the main screen of the exercise test 2 Or press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor to Return and then press to return to the main screen of the exercise test NOTE The setting methods of filter recorder and lead of the exercise ECG are the same as those of the resting ECG For details about the setting methods please refer to Section 11 2 Filter Setup Section 11 3 1 Setup 1 and Section 11 6 Lead Setup 12 4 1 General Information Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on General Info on the System Setup screen press to open the General Information Setup window 165 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional General Information Setup Ce mph AxS Treadmill Cancel Figure 12 2 General Information Setup window Press Tab or Shift Tab to move the cursor to a list box and then press the Up or Down arrow to highlight an option Or press Tab or Shift Tab to move the cursor to a textbox and then fill in the textbox After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 1 Display Style When Display Style is set to 3x1
150. re 12 3 Record Info Setup window Press Tab or Shift Tab to move the cursor to a list box and then press the Up or Down arrow to highlight an option Or press Tab or Shift Tab to move the cursor to a textbox and then fill in the textbox Or press Tab or Shift Tab to move the cursor to a checkbox and then press Spacebar to select or deselect it 168 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 1 Exercise Report When Close is highlighted 12 lead ECG report of the exercise phase will not be printed out automatically during the exercise test When Early Stage is highlighted 12 lead ECG report will be printed out automatically at the early period of each stage of the exercise phase When Middle Stage is highlighted 12 lead ECG report will be printed out automatically at the middle period of each stage of the exercise phase When Late Stage is highlighted 12 lead ECG report will be printed out automatically at the late period of each stage of the exercise phase 2 Recovery Report When Output is deselected 12 lead ECG report of the recovery phase will not be printed out automatically during the exercise test When Output is selected 12 lead ECG report of the recovery phase will be printed out automatica
151. recharged the electrocardiograph can be powered by the mains supply WARNING Potential equalization conductor of the unit should be connected to the potential equalization bus bar of the electrical installation when necessary 4 SE 12 Series Electrocardiograph User Manual Operation Preparations 4 2 Loading Replacing Recorder Paper Two kinds of recorder paper can be used One is the folded thermal paper and the other is the rolled thermal paper NOTE 1 When the folded thermal paper is used the paper roller is unnecessary and must be taken out 2 When using the paper of 216mm in width the two movable parts should be removed 3 The exit edge can help you tear the recorder paper CAUTION Make sure that the recorder paper especially the rolled paper is installed in the center of the recorder and the paper edge is parallel with the casing edge in the direction of advancing paper in order to avoid paper deviation or damage to the paper edge When the recorder paper runs out or is not loaded the hint message No Paper will appear on the screen Then you should load or replace the recorder paper immediately Groove Movable Movable Part 1 Part 2 Paper Tray Exit Edge Edge for Casing Button tearing paper Exit Paper Roller Casing 42 SE 12 Series Electrocardiograph User Manual Operation Preparations Loading Replacing Process of Folded Paper
152. rker do not work in the auto style of 3x4 3x4 1R and 3x4 3R and the style of 6x2 and 6x2 1R in the Save Paper mode 2 To get more information about the above contents please refer to Section 8 6 1 ECG Reports in the Auto Mode 11 4 Patient Information Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Patient Info on the System Setup screen press to open the Patient Information Setup window 127 SE 12 Series Electrocardiograph User Manual System Setup Patient Information Setup auto fon confirmed by E jem kg EY mmtg or After Recording TTT OK Press lt Tab gt or lt Shift Tab gt to move the cursor Figure 11 6 Patient Information Setup window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 4 1 Selecting First Last Name Gender D O B Height Weight BP Race Pacemaker Medication Room No Department Physician Technician Ref Physician Press Tab or Shift Tab to move the cursor to an item in the Patient Information Setup window and then press Spacebar to select or deselect the item When First Last Name Gender D O B Height Weight BP Race Pacemaker Medication Room No Department Physician Technician or Ref Physician is selected the item will be displayed i
153. roof Disinfection sterilization method Refer to the user manual for details Degree of safety of application in the presence of flammable gas Equipment not suitable for use in the presence of flammable gas Working mode Continuous operation EMC Group I Class A Patient NC lt 10pA AC lt 10uA DC Leakage Ghent SFC lt 50uA AC lt 50uA DC Patient NC lt 10pA AC lt 10uA DC Auxiliary C rtent SFC lt 50uA AC lt 50uA DC A1 2 Environment Specifications Transport amp Storage Working Temperature 20 C 4 F 55 C 131 F 5 C 41 F 40 C 104 F Relative Humidity 25 93 25 80 Non Condensing Non Condensing Atmospheric Pressure 700hPa 1060hPa 860hPa 1060hPa 187 SE 12 Series Electrocardiograph User Manual Technical Specifications A1 3 Physical Specifications SE 12 420mmx330mmx 105mm 16 5inx13 0inx4 1in Dimensions SE 12 Express 420mmx330mm 120mm 16 51nx 13 0inx4 7in SE 12 approx 5 0kg 11 0 Ibs SE 12 Express approx 6 5kg 14 3 lbs Weight Excluding recorder paper and battery 320x240 dot single color LCD Screen Display 800x600 multicolor LCD Screen A1 4 Power Supply Specifications Operating Voltage 100V 240V Mains Supply Operating Frequency 50Hz 60Hz Input Current 0 9 0 4A SE 12 Express Rated voltage 14 8V Int l
154. rs or selecting deselecting a checkbox Shift Pressing Shift Tab can move the cursor backward Press Shift and a number key to input the special character in the top right corner of the key If Caps Lock is set to Off pressing Shift P can type a capital P If Caps Lock is set to On pressing Shift P can type a lowercase p Esc Reset Canceling operation NOTE A large polarization voltage may cause baseline drift On the main screen pressing the ESC key can decrease the polarization voltage and draw the baseline to zero quickly Power On Off Power on Power off MODE Press this key to select a working mode among the auto manual rhythm R R analysis and off modes NOTE Only if a working mode is ticked in the Work Mode Setup window can the working mode be selected by pressing the MODE key when the main screen is displayed 15 2 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application L SLEEP WAKE UP Resting wakening the electrocardiograph M COPY In the auto mode pressing the Copy key can print the ECG report which was printed out last time N START STOP O Arrow Keys Start Stop printing reports Moving the cursor Up Down Left Right In the manual mode press the Up or Down arrow to switch the lead groups During the exercise test pressing the Up or Down arrow can switch the display style When the displa
155. s 28 Interval of Recovery Report 2min 29 Summary Report On 30 ST Scope Report On 31 Trend Graph Report On 32 Edit Conclusion On 11 10 7 Setting System Password Press Tab or Shift Tab to move the cursor to the System Password textbox in the System Maintenance window and then enter the password If you set the system password after you press the function key F6 below Setup the System Password window will pop up After you enter the correct password the System Setup screen will be displayed 152 SE 12 Series Electrocardiograph User Manual System Setup 11 11 Other Setup Press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Other on the System Setup screen press to open the Other Setup window Other Setup jo lil Standard Triggered Cancel Figure 11 13 Other Setup Window After setup press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm Then the System Setup screen appears 11 11 1 Entering Institution Press Tab or Shift Tab to move the cursor to the Institution textbox on the Other Setup Window and then manually input the institution name within 40 ASCII characters NOTE The total number of supported characters may be fewer if either special Latin characters or Chinese characters are entered 11 11 2 Selecting a Language Press Tab or Shift Tab to move the cursor to
156. s the START STOP key to stop printing the ECG report 8 3 Rhythm Mode Operation Method 1 To set Mode Options Rhythm Style Rhythm Lead1 2 3 or Lead Sequence Optional When the main screen is displayed press the function key F6 below Setup to open the System Setup screen The cursor is on Work Mode Press to open the Work Mode Setup window 1 Press Tab or Shift Tab to move the cursor to RHYT press Spacebar to select it and then a check mark V appears in the box before RHYT 2 Press Tab or Shift Tab to move the cursor to the Rhythm Style list box and then press the Up or Down arrow to highlight a style 3 Press EZA or press Tab or Shift Tab to move the cursor to the OK button and then press f 72 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 4 5 6 7 Work Mode Setup Real time Sample Triggered Sample Periodic Sample 60 a Three Leads 12 channels On the System Setup screen press Tab or Shift Tab or the Up Down Left or Right arrow to move the cursor When the cursor is on Lead press to open the Lead Setup window Press Tab or Shift Tab to move the cursor to the Rhythm Lead1 2 3 list box and then press the Up or Down arrow to select a lead Press Tab or Shift Tab to move the cursor to the Lead Sequence list box and then press the Up or Down arrow to select a sequence Press e or press Tab or Shift Tab to move the curso
157. screen Protocol Manager Add Edit Select Delete Del All Restore Return Figure 12 4 Protocol Manager Screen 1 Add Press the function key F1 below Add to display the following dialog box 170 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional Add Protocol Cancel In the Add Protocol dialog box firstly you should enter the new protocol name in the Protocol Name textbox and then enter the stage information of every stage including the time speed and grade After that press Tab or Shift Tab to move the cursor to the OK button and then press to confirm NOTE When Time of a stage in the exercise phase is set to 00 this stage and its following stages in the exercise phase will not be carried out 2 Edit Select a protocol on the Protocol Manager screen by pressing the Up or Down arrow and press the function key F2 below Edit to display the Edit Protocol dialog box Then you can edit the protocol information 171 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional Modified Bruce H LLLE Blsl all Sl sl l LL LLLLLG NOTE For the Bruce or Modified Bruce protocol only the stage information of the pretest and recovery phases can be edited 3 Select Select a protocol on the Protocol Manager screen by pressing the Up or Down arrow and press the function key F3 below Select to set th
158. should connect the corresponding USB printer to USB socket 2 of the electrocardiograph with a special cable Press the START STOP key to print ECG reports by using the USB printer WARNING If the printer used is not the type listed above additional safety measures such as applying an isolation transformer to supply the medical system should be taken when the safety of the medical system has not been evaluated If in doubt consult our technical service department or your local distributor 124 SE 12 Series Electrocardiograph User Manual System Setup Options Corresponding USB Printers HP DJ D2468 HP Deskjet 3938 HP Deskjet D2368 HP Deskjet D2468 HP DJ D5568 HP Deskjet D2568 HP Deskjet D5568 HP LJ P2035 HP Laserjet P2015 HP Laserjet P2035 NOTE 1 During the USB printing course pressing the START STOP key again can not stop printing ECG reports 2 For details of the ECG report printed by the USB printer please refer to Section 8 6 5 ECG Reports Printed by the USB Printer 3 USB printing is ineffective in the auto periodic sampling mode auto 11 24s sampling mode manual mode and R R analysis mode 4 Make sure that paper is installed in the USB printer before printing Error may occur if no paper is loaded in the USB Printer CAUTION It is forbidden to frequently connect or disconnect the U disk or the USB printer 11 3 1 6 Setting Speed Press Tab or Shift T
159. son Age 725 Years Gender Female Height 165 cm Weight 50 kg Room No 0023 Department Average Template HR 60 BPM P Dur 94 ms PR int 174 ms QRS Dur 79 ms I PVR vi V4 l QT QTC int 354 354 ms I UEA ae eae P QRS T axis 55 45 54 g F RVS SV1 amp 1 042 0 536 mY RVS5 SV1l amp 1 578 mV RV6 SV2 amp 0 736 0 882 mV H aVi v2 vsih kan f L ais a YEN I Diagnosis Information 800 Sinus Rhythm Normal ECG aVE j v3 4 V6 Report Confirmed by i 0 67 100Hz AC50 25mm s 10mm mV Institution Name SE 12Express V1 8 SEMIP V1 5 b The above figure a and b show an ECG report in the auto mode Template is selected and Record Style is set to 6x2 1R Figure a shows 02 06 2010 16 52 40 Current Date amp Current Time ID 001 Patient ID Name Marry Johnson Patient Name Age 25 Years Patient Age Tl 1mV calibration mark I II IW aVR aVL aVF V1 V2 V3 V4 V5 V6 12 standard leads and ECG waves II on the bottom Rhythm Lead and rhythm wave 0 67 100Hz 0 67Hz DFT Filter 100Hz Lowpass Filter ACS50 50Hz AC Filter 25mm s Paper Speed 10mm mV Gain 79 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 2 5s I1r 12 leads are printed in 2 groups of 6 and every group is printed for about 5s with one rhythm lead at the bottom simultaneously Institution Name SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm V
160. soocesoeesocsssocesoceeoosesosssoesssocescocssooseso 196 VII SE 12 Series Electrocardiograph User Manual Safety Guidance Chapter 1 Safety Guidance This chapter provides important safety information related to the use of the 12 channel electrocardiograph 1 1 Intended Use The intended use of the 12 channel electrocardiograph is to acquire ECG signals from adult and pediatric patients through body surface ECG electrodes The electrocardiograph is only intended to be used in hospitals or healthcare facilities by doctors and trained healthcare professionals The cardiogram recorded by the electrocardiograph can help users to analyze and diagnose heart disease However the interpreted ECG with measurements and interpretive statements is offered to clinicians on an advisory basis only WARNING 1 This equipment is not designed for internal use or direct cardiac application 2 This equipment is not intended for home use 3 This equipment is not intended for treatment or monitoring 4 This equipment is intended for use on adult and pediatric patients only 5 The results given by the equipment should be examined based on the overall clinical condition of the patient and they can not substitute for regular checking 1 2 Warnings and Cautions In order to use the electrocardiograph safely and effectively and avoid possible dangers caused by improper operation please read through the user manual and be sure to be familiar with all fun
161. sressessessees 119 11 1 7 Selecting Preview Punenoncscsisten sce aac fan ah oc cscs hace vee ghd cart anal gator Gears 119 11 1 8 Selecting Auto Extend Record i s cccssscsssisestesodiatiectan iaetaesd onan taacae erleandedin shee edestonanats 119 LL Filter Setup inean eres Saee aids Meee Aa eae Ae ame aia 119 W2 As SU yA WNC neen ets ths deel Goo eccasiea tester E aac E AN 120 ERs oy 11 va DET Filtet apun RN REO Pat RIA RE rh e ee eran Ree Ree a 120 23 tL EMG Filteren n shcpb at e a uassutohantudura umn a a a a a 121 PsA Setting Low pass Pte cs icsesace irinae i E A A aN ani RARE 121 11 3 R cord Info Set pai i a r a terial Sons needa an E A Passat 122 A SN Setup sects ens oleh A eas ul E oak AAR e ns 122 11 32 SEP Zeca hes ore aria sacs R N R a E At A 126 11 4 Patient Information Setup sascssssaecesviatecttetenned ostugiaay baleaadteastaGlaaiuucnGeasteedatauins 127 11 4 1 Selecting First Last Name Gender D O B Height Weight BP Race Pacemaker Medication Room No Department Physician Technician Ref Physician 128 11742 Sel cting ID Mode caf des cached ticles a a a aa deuse es bende ante eave aucy eehtcnen sacs 128 TA Se Ve Cit 7 MID HN isdekcdu cas secey asides sh sparta a a a i a e a a dts 129 DPA AA Setting Prompte inienn eaan a a aE EEA AA E EEEa AAEE EA RTA ieee 129 11 4 5 Selecting VW UI nenesie sie a et Sa E E E E 129 11 4 6 Selecting BP Units s cishirccitceantiiei E E E T E E N 130 1 4 7 Select
162. ssing F4 can switch the paper speed and pressing F5 can switch the gain Press the START STOP key to print the previous ECG report again according to the settings of the auto style speed and gain which are shown on the bottom of the screen 001 F AUTO 12 00 01 Marry Johnson 25Y E aVF SamePatient NextPatient _5x4 1R_ _25mm s_ 10mm mV 130 SE 12 Series Electrocardiograph User Manual System Setup When Next Patient is set to Off in the auto mode the system will not automatically display the next patient screen after a complete ECG report is printed 11 4 8 Setting the Time to Clear Patient Information Press Tab or Shift Tab to move the cursor to Patient Info Cleared in the Patient Information Setup window Press the Up or Down arrow to highlight an option If Patient Info Cleared is set to After Recording the patient information will be cleared after the ECG report is printed out If Patient Info Cleared is set to After Recording And Lead Off the patient information will be cleared after the ECG report is printed out and all the leads are off NOTE This function is unavailable in the manual mode 11 4 9 Inputting Customized Information Press Tab or Shift Tab to move the cursor to the User Defined textbox in the Patient Information Setup window and then manually input customized information such as Address which will be displayed in the Patient Information window 11 5 Transmission Setup
163. t there is enough recorder paper loaded correctly 6 Patient The patient should not come into contact with conducting objects such as earth metal parts etc Ensure that the patient is warm and relaxed and breathes calmly WARNING The electrocardiograph is intended to be used by qualified physicians or personnel professionally trained and they should be familiar with the contents of this user manual before operation 55 SE 12 Series Electrocardiograph User Manual Turning on the Electrocardiograph Chapter 5 Turning on the Electrocardiograph When the mains supply is used connect the power cord and the mains supply indicator L is D moe lit Then press on the keyboard to turn on the unit The logo will be displayed on the LCD screen after self test Then the electrocardiograph is ready for use When battery is used press on the keyboard directly to turn on the unit and then the battery indicator a is lit The logo will be displayed on the LCD screen after self test Then the electrocardiograph is ready for use 56 SE 12 Series Electrocardiograph User Manual Entering Patient Information Chapter 6 Entering Patient Information After the electrocardiograph is turned on the main screen appears For SE 12 Express pressing the Pretest key can open the main screen of the exercise test 6 1 Entering Patient ID 1 By default the system generates the patient ID automatically The range
164. tes that the device should be sent to the special X agencies according to local regulations for separate collection after its useful life 10 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application Chapter 2 Introduction The 12 channel electrocardiograph gathers ECG signals of 12 leads simultaneously It displays the operation menu ECG parameters as well as electrocardiograms The 12 channel ECG waves can be viewed on the LCD screen and printed out by using a high quality thermal recorder The sampled ECG data can be saved transmitted and exported The manual auto rhythm R R analysis or off mode can be chosen freely For SE 12 Express the exercise ECG function is optional When a patient with coronary heart disease runs the added heart load will cause myocardium hypotension and then the ECG will change abnormally Therefore the exercise ECG function of SE 12 Express can be used to diagnose concealed coronary heart disease and atypical angina pectoris prescribe the workload for patients with myocardial infarction before they leave hospital and assess the effect of the treatment The 12 channel electrocardiograph can be powered by the mains supply or battery With a high resolution thermal recorder a 32 bit processor and a large capacity memorizer the 12 channel electrocardiograph has advanced performance and high reliability The compact size makes it suitable for clinic and hos
165. the EMG filter should be set to Off and the Lowpass filter should be set to 150Hz or else the amplitude of the pulses may decrease the width may increase and the diagnosis results may not include the pacemaker information 2 To the patient with a pacemaker the results given by the equipment may be invalid 8 6 7 ECG Report of Nehb Lead 30206 2010 17 45 16 3805742 ID 001 Age 25 Years Name Marry Johnson I S as FAR ED fre Set ar ea ors get ED EE oe ne See ee re es UER ag een BEE TES re EE ed oo IIT ecto ee ee Bon a et ee EES ee Se es ee Nt te 4 j J i 4 j n n f j j NA l h r J j HE oe WE Tonik S LL a E a EE oD l HE a L NI N f N n f A a 0 67 100Hz AC50 25mm s 10mm mV 60 Institution Name SE 12 EXPRESS V1 8 SEMIP V1 5 ECG report of Nehb lead includes 30 06 2010 17 45 16 Current Date amp Current Time ID 001 Patient ID Age 25 Years Patient Age Name Marry Johnson Patient Name Tl 1mV calibration mark I II W ND NA NI Nebb leads 90 SE 12 Series Electrocardiograph User Manual Printing ECG Reports 0 67 100Hz 0 67Hz DFT Filter 100Hz Lowpass Filter ACS50 50Hz AC Filter 25mm s Paper Speed 10mm mV Gain 60 Heart Rate Institution Name SE 12 Express Electrocardiograph Model V1 8 Software Version Number SEMIP V1 5 Algorithm Version Number 9 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Aut
166. the current stage Current Speed or Rotation Speed Grade or Power Workload When the treadmill is used the current speed grade and workload of the treadmill will be displayed on the main screen When the ergometer is used the current rotation speed and power of the ergometer will be displayed on the main screen Current Time Current examination time Refer to Section 11 8 1 Setting Date and Time Battery Symbol Systolic Blood Pressure and Diastolic Blood Pressure Identify the current capacity of the battery C Full capacity CE 23 capacity DEY 1 3 capacity Empty The left number is the systolic blood pressure and the right number is the diastolic blood pressure Current Heart Rate and The left number is the current heart rate and the right number is the target heart rate Target Heart Rate 30 is the percentage of the current heart rate to the target heart rate Press the function key F7 below Exit to exit the main screen of the exercise test xi In the exercise test the Exit button changes into the ST Trend or Template button Press the function key F6 below Setup to open the System Setup screen Setup f In the exercise phase the Setup button changes into the Lead button Filt EMG Filter 25Hz 35Hz or 45Hz ilter Lowpass Filter 75Hz 100Hz or 150Hz Gai Gain 2 5 mm mV 5 mm mV 10 mm mV 20 mm mV 10 5 ain mm mV or AGC Post J is the length after J po
167. the electrocardiograph the files in the directory of ECGDATA ECG 01 Import of the U disk will be imported 132 SE 12 Series Electrocardiograph User Manual System Setup 11 5 2 Selecting Auto Transmission Press Tab or Shift Tab to move the cursor to Auto Transmission and then press the Up or Down arrow to select On or Off When Auto Transmission is set to On in the auto or rhythm mode ECG data will be transmitted automatically after an ECG report is printed out in the off mode ECG data will be transmitted automatically after the START STOP key is pressed 11 5 3 Selecting Transmission Mode Press Tab or Shift Tab to move the cursor to Transmission Mode and then press the Up or Down arrow to highlight Ethernet or UART When Transmission Mode is set to Ethernet first connect the net port of the electrocardiograph to the net port of the PC by using an Ethernet cable recommended by the manufacturer Then set all the items in the Transmission Setup window In the auto rhythm or off mode ECG data can be transmitted through the net cable automatically When Transmission Mode is set to UART first connect serial port 1 of the electrocardiograph to the serial port of the PC by using a serial cable recommended by the manufacturer In the auto rhythm or off mode ECG data can be transmitted through the serial cable automatically 11 5 4 Setting FTP Information To Enter FTP Path FTP User Name and Password Press Tab or Shift
168. tion of the Local IP item can be set at random but it can t be the same as the last section of the IP of the PC 7 Press Tab or Shift Tab to move the cursor to the Gateway item Set the first three sections of the Gateway item to the first three sections of the IP of the electrocardiograph The last section of the Gateway item must be set to 1 NOTE For more information on configuring network settings see your Network Administrator Take the same network transmission for example View the IP of the PC Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capabiity Otherwise you need to ask your network administrator for the appropriate IP settings Qbtain an IP address automatically tanec olioa ddus 192 168 E Defaut gateway 192 168 7 31 Use the following DNS server addresses Preferred DNS server 192 168 eA ARemate ONS server 202 96 134 133 95 SE 12 Series Electrocardiograph User Manual Transmitting ECG Data Automatically In the Transmission Setup window of the electrocardiograph set Transmission Mode to Ethernet Set the Server IP item to the IP of the PC Set the first three sections of the Local IP item to the first three sections of the IP of the PC The last section of the Local IP item is not the same as the last section of the IP of the PC Set the first three sections o
169. umption during the storage and transport course the battery capacity is not full when it is used for the first time Battery recharge should be considered before the first use CAUTION Repeated undercharging of the battery will damage the battery and reduce battery life 179 SE 12 Series Electrocardiograph User Manual Cleaning Care and Maintenance 3 Replacement When the useful life of the battery is over or foul smell and leakage are found please contact the manufacturer or the local distributor for replacement WARNING 1 Only qualified service engineers authorized by the manufacturer can open the battery compartment and replace the battery and the battery of the same model and specification provided by the manufacturer must be used 2 Danger of explosion Do not reverse the anode and the cathode when installing the battery 3 Remove the battery from the electrocardiograph when the electrocardiograph is not used for a long time 4 lf the battery is stored alone and not used for a long time we recommend that the battery should be charged at least once every 6 months to prevent overdischarge 5 When the battery s useful life is over contact the manufacturer or the local distributor for disposal or dispose of the battery according to local regulations CAUTION If the battery has been fully charged and requires recharging after printing only a few ECGs consider replacement 15 3 2 Recorder Paper NOTE
170. unded 2 Test the emergency stop switch of the treadmill before using the system 3 During the exercise test ensure that there are at least 2 experienced physicians present One of them observes the patient and deals with the emergency 4 Make sure that there is necessary valid first aid equipment such as defibrillators blood pressure meters etc and necessary valid medication in the exercise test room 5 Turn off the system power and disconnect the power cord from the wall outlet after using the system 6 Press down the emergency stop switch of the treadmill before defibrillating to avoid the hazard to the patient and the operator sbs SE 12 Series Electrocardiograph User Manual Safety Guidance 10 11 12 13 14 15 16 17 18 19 20 emergency happens WARNING Keep the treadmill ergometer on a horizontal place and make sure it s stably working Make sure that the power cable of the treadmill ergometer is grounded Don t use other electrical equipment with the same power supply line Keep the power cable far away from the running treadmill area and the heat surface Examine the treadmill ergometer carefully before using it Do not take an exercise test if the treadmill ergometer is wet Do not use the treadmill ergometer in the open air The patient undergoing the stress exercise test should wear suitable clothes and shoes During the stress exercise test the patient should not get on or o
171. urfaces of electrodes will be oxidized because of erosion and other causes By this time electrodes should be replaced to achieve high quality ECG records CAUTION The device and accessories are to be disposed of according to local regulations after their useful lives Alternatively they can be returned to the dealer or the manufacturer for recycling or proper disposal 183 SE 12 Series Electrocardiograph User Manual Accessories List Chapter 16 Accessory List WARNING Only the patient cable and other accessories supplied by the manufacturer can be used Or else the performance and electric shock protection can not be guaranteed Accessory Part Number 01 57 107581 Snap Style ECG Cable European 01 57 107583 Grabber Style 01 57 107582 Snap Style ECG Cable American 01 57 107584 Grabber Style Patient Cable American 01 57 107048 Patient Cable European 01 57 106902 ECG Chest Electrodes 02 04 110842 ECG Limb Electrodes 02 04 110843 Pediatri Di l Adhesi ediatric isposable dhesive 11 57 40024 Electrodes Disposable Neonatal Electrode 11 57 40109 Adult Disposable Adhesive Electrodes 11 57 040159 Disposable Resting Tab electrodes 1 Bposabie Resume Tam Seen Odes LEN iga jagia piece Power cord European 01 13 36014 Power cord American 01 13 036106 Power cord American 11 13 36015 Rechargeable Li ion Battery 21 21 064146 Snap Banana Socket Ad
172. w If Pacemaker is set to Yes the pacemaker signals are easy to be detected If Pacemaker is set to No the pacemaker signals are not easy to be detected BP mmHg Patient Systolic Blood Pressure Diastolic Blood Pressure Race Patient Race unknown Oriental Caucasian Black Indian Mongolian Hispanic Asian Pacific other Medication The medication which patient took previously Within 30 ASCII characters Room No Room Number Within 10 ASCII characters Department Within 30 ASCII characters Physician Physician Name Within 35 ASCII characters Technician Technician Name Within 35 ASCII characters Ref Physician Referring Physician Name Within 35 ASCII characters NOTE The total number of supported characters may be fewer if either special Latin characters or Chinese characters are entered Operation Procedures are as follows 1 Press Tab or Shift Tab to move the cursor to a textbox Fill in the selected textbox For details on inputting data please refer to Section 3 2 Entering Data 2 Press Tab or Shift Tab to move the cursor to a list box Press the Up or Down arrow to select an option 59 SE 12 Series Electrocardiograph User Manual Entering Patient Information 3 After inputting all the information press to confirm or press Tab or Shift Tab to move the cursor to the OK button and then press to confirm NOTE If you select D O B in the Patient Information Setup window the D O B
173. ww edanusa com San Deigo CA 92117 Tel 888 850 4597
174. x and then press the Up or Down arrow to select On Press Tab or Shift Tab to move the cursor to the Saving Path list box and then press the Up or Down arrow to select ECG 4 Press ca or press Tab or Shift Tab to move the cursor to the OK button and then ge SS 5 When the System Setup screen is displayed press ESC to return to the main screen To Switch to the File Manager screen 1 2 When the main screen is displayed press the function key F7 below File to open the File Manager screen1 Press the Up or Down arrow to highlight a file on the File Manager screen1 and then press the function key F4 below Select to select the file and display the File Manager screen2 Then press the function key F7 below Return to return to the File Manager screen1 Press the function key F7 below Return on the File Manager screen to return to the main screen 102 SE 12 Series Electrocardiograph User Manual Managing Files File Manager 1 200 Name ID Time Mode Marry Johnson 2010 04 08 10 50 26 AUTO Trans All File Manager 1 200 Name ID Time Mode Marry Johnson 00i 2010 04 08 10 50 26 AUTO Edit Record Trans Export Figure 10 2 File Manager screen2 On the File Manager screen files can be printed transmitted exported displayed edited searched or deleted SE 12 can accommodate 100 files and SE 12 Express can accommodate 200 files If there is no file on the File Manager screen the following dialog box w
175. xercise test 8 Setting the treadmill or the ergometer for external control 1 For TM 400 treadmill it is ready for external control and needn t be set 2 For Lode Treadmill Valiant Hold down the following two keys for 10 seconds and then you will enter the service menu of the Valiant By default the Valiant is shipped with the Lode RS232 communication protocol It should be set to the Trackmaster RS232 protocol You can change the communication protocol by following the procedures below 162 SE 12 Series Electrocardiograph User Manual Operation Instructions for Exercise ECG Optional gt Select Prot id and select the second RS232 protocol which is the Trackmaster communication protocol gt Select Baudrate and set this to 4800 Baud gt Press the red button to leave the service menu gt Turn off the Valiant 3 For Lode ergometer gt Turn on the ergometer By default the Corival ergometer is shipped with the LODE RS232 communication protocol It should be set to the ERGOLINE P4 protocol You can change the RS232 protocol by following the procedures below Turn on the ergometer and press Enter You will be in MAINMENU Select by using the Up Down keys the menu SYSTEM PARAMETER and press Enter Select by using the Up Down keys the menu SETTINGS and press Enter Select by using the Up Down keys the menu RS232 PROTOCOL and press Enter Select by using the Up Down keys ERGOLINE P4 and press Enter
176. xt Page to turn pages Press F2 below Pre Sec or F3 below Next Sec to view the ECG waves of the previous or next second Press the function key F5 below Play to display ECG waves continuously Press the function key F6 below Pause to stop playing ECG waves Press the function key F7 below Return to return to the main screen 65 SE 12 Series Electrocardiograph User Manual Printing ECG Reports Chapter 8 Printing ECG Reports There are four modes to print ECG reports In the auto mode the lead groups are switched automatically according to the lead sequence during the printing course After the ECG waves of one lead group are printed within a certain time the system switches to print ECG waves of another lead group automatically A 1mV calibration mark will be printed at the beginning of an ECG report In the manual mode you can determine the lead group to be displayed and printed by pressing the Up or Down arrow In the rhythm mode you can print 60s rhythm lead ECG waveform of one lead in the Single Lead style or 20s rhythm lead ECG waveform of three leads in the Three Leads style In the R R analysis mode you can select a lead to print its R R histogram R R trend chart 180s compressed ECG waveform and all the R R interval values NOTE 1 The working mode can not be changed during the printing course Stop printing reports before changing the working mode 2 Within three seconds after returning to the main screen
177. y style is 3x1 pressing the Left or Right arrow can switch the lead group 2 3 Front Panel Figure 2 5 SE 12 Express Front Panel 16 SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application mia Figure 2 6 SE 12 Front Panel Symbol Name Explanation A o Mains supply When the device is powered by the mains supply indicator this indicator is lit B a de When the device is powered by battery this Battery indicator ar fates indicator is lit C I Battery recharging When the battery is being recharged this indicator indicator is lit 2 4 Rear Panel ji Figure 2 7 SE 12 Express Rear Panel Lit SE 12 Series Electrocardiograph User Manual About the Electrocardiograph Application A 3 oo CID _ m B C D Figure 2 8 SE 12 Rear Panel Name Explanation A Mains Supply Socket AC SOURCE alternating current supply socket Potential Equalization Y Potential equalization conductor provides a B Conductor connection between the unit and the potential equalization bus bar of the electrical installation Handle Part for people to hold D Heat Emission Hole Path for internal heat emission 2 5 Right Panel C a a i La lt r e Hes ME oe R ia Figure 2 9 SE 12 Express