Home

Manual - Avaya Paging Solutions

image

Contents

1. Rack or wall mount UL listed power supply FCC Part 15 approved Figure 1 1 shows a back view of the Ambient Level Controller ALC and Figure 1 2 shows a front view of the ALC Figure 1 3 shows a block diagram of the ALC O Model FM 15 Power Input Telco In 24 Volts AC Loop Start m O Relay Outputs Output Line Out Mic Only Mic Only he Ne No Ne No Level EGTE Line In Shield Or gt SPELL Clock Inputs or Remote Control 24dB 24dB 18dB 12dB 6dB d d SB Oe Figure 1 1 Back View 18 dB 24 dB Manual Level Control Noise Level Paging Level Set Maximum Noise Level dB SPL dB 105dB Full Volume sod joe 95dB 6 dB 85dB 405dB 85dB 12 48 75dB 18 dB 65dB 24 dB Automatic Level Control Telephone Input Active 0 DBM C1 Loop St di X 1 Buffer 2 Figure 1 2 Front View 4to 0 to 5 Volt LED 20 Mil Driver Rec Audio Detect Gain Hold LED Display Converter Converter X 1 Buffer or Level Set Figure 1 3 Ambient Level Controller Block Diagram 4 Volume Control 1 Over rides i for High Noise Level FP Manual or Automatic Level Control Selection Selector for Max Noise FP PA Level Display Overview 1 3 Specifications Eg AV ON OA EE EE EE Table 1 1 lists the specifications for the ALC Table 1 1 Specifications Parameter Working Limits Power So
2. the radio or TV receiver or vice versa Plug the Ambient Level Controller unit into a different outlet so that it and the radio or TV receiver are on differ ent branch circuits If necessary the user should consult the dealer or an expe rienced radio television technician for additional sugges tions The user may find the following booklet How To Identify and Resolve Radio TV Interference Problems helpful This booklet was prepared by the Federal Communications Commission FCC and is available from the U S Government Printing Office Washington DC 20402 Stock order No 004 000 00345 4 Important Safety Information Always follow these basic safety precautions when installing and using the system 1 Read and understand all instructions 2 Follow all warnings and instructions marked on the prod uct 3 DO NOT block or cover the ventilation slots and open ings They prevent the product from overheating DO NOT place the product in a separate enclosure or cabinet unless proper ventilation is provided 4 Never spill liquid on the product or drop objects into the ventilation slots and openings Doing so may result in seri ous damage to the components 5 Repair or service must be performed by a factory authorized repair facility 6 The product is provided with a UL CSA approved 3 wire ground type plug This is a safety feature DO NOT defeat the safety purpose of the grounding type plug DO NOT staple or otherwise a
3. ABLE TRI ao Fa P R ria seel AMPLIFIER Figure 3 3 FM 15 ALC Connection to a LUUPAM Universal Paging Access Module Installation 3 5 VV EE Note The controller must be Multiple FM 15 ALCs may be used with a single controller so each zone has its switching line level only own level correction see Figure 3 4 CAUTION Use only the FM 14 Log Current Microphone A standard microphone will be damaged if connected to the FM 15 SWITCH MUST BE IN LO PWR POSITION FL Line Out to Page Input RCA CABLE D CA e S MUSICIN BROGING Sma cia oe nia PRE EET Bealls Figure 3 4 FM 15 ALC Used With A Paging Control System LUPCMALL Installation 3 6
4. AVAYA Ambient Level Controller Installation and Use Manual Issue 1 October 1999 1999 Bogen Communications Inc All rights reserved 54 2028 01 9910 Model LUALC PEC Code 5335 621 COM Code 408184273 Select Code 701 000 131 1999 Bogen Communications Inc All Rights Reserved Printed in U S A Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of print ing However information is subject to change FCC Statement Part 15 Radio Frequency Interference The Ambient Level Controller generates and uses radio fre quency energy and if not installed and used in strict accor dance with the manufacturer s instructions may cause inter ference to radio and television reception Testing is being conducted for compliance with the limits for a Class B device in accordance with the specifications in Part 15 of the FCC Rules This testing is designed to provide reason able protection against such interference However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the Ambient Level Controller unit off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the radio or TV receiving antenna Relocate the Ambient Level Controller unit with respect to
5. Figure 2 2 FM 15 ALC Rear View Operation 2 3 FM 14 Log Current Microphone Hookup The wire for the FM 14 Log Current Microphone does not have to be shielded Use an RJ 11 connector at the microphone When connecting to the FM 15 ALC use an RJ 11 connector or wire directly to the terminal strip marked MIC ONLY see Figure 2 3 OR NOTE These terminals are redundant MIC input connections useful when a Modular RJ 11 Plug and cable is not suitable Line Out Mic Onl Mic Only ay be Output Level SOS SI Figure 2 3 FM 14 Log Current Microphone 2 4 Operation Installation Contents Power Supply Hookup 3 2 Mounting Detail 3 3 Ambient Level Controller Connection With A LUUPAM Universal Paging Access Module 3 5 Ambient Level Controller Connection With LUPCM Paging System 3 6 Installation 3 1 Power Supply Hookup Install the FM 15 ALC with the system to be controlled Then install the FM 14 Log Current Microphone in the area to be controlled Connect the power supply provided as marked on the PC board BLACK WHITE RED GREEN from left to right see Figure 3 1 a O i Power Input lodel FM 15 Telco In 24 Volts AC Loop Start Line In ac Output Line Out Level 3 2 wo POWER SUPPLY 24VAC 1 6 60 HZ DO NOT DEFEAT THE SAFETY GROUNDING PIN ON THE POWER LUG Figure 3 1 Power Supply Hookup 3 2 Installation Mounting Detail T
6. efore installing your system read and understand the safety instructions Be sure you have all the necessary parts tools and test equipment listed below Check the shipping container for the following contents 1 FM 15 Ambient Level Controller 2 FM 14 Log Current Microphone 3 Rack mounting ears 4 Rack mounting hardware 4 Phillips head 12 24 screws 8 Phillips head 6 32 screws 5 RJ 11 cord 6 Power supply 7 Installation and User Manual 8 Male RCA to wires cable Overview 1 5 This page intentionally left blank 1 6 Overview Operation Contents Front Panel Setup 2 2 Manual Use of the FM 15 Ambient Level Controller 2 3 FM 14 Log Current Microphone Hookup 2 4 Operation 2 1 2 2 Front Panel Setup Set up the FM 15 ALC as follows 1 Set the MANUAL LEVEL CONTROL to automatic Blue Knob see Figure 2 1 This allows the FM 15 ALC to calibrate itself The automatic position will allow the FM 15 ALC to constantly change the paging level to compensate for the changes in noise level in the area being monitored 18 dB 24 dB Manual Level Control Manual Level Control Blue Knob Operation 2 Check the SPL meter the Green LED see Figure 2 1 for maximum noise level This is your high noise level reading 3 Set the MAXIMUM NOISE LEVEL control Red Knob see Figure 2 1 to the average high noise level If you feel the room noise may actually be louder at some time move the contr
7. he rack ears mount in any of four directions see Figure 3 2 This makes rack mounting or wall mounting possible The power supply can be mounted in any convenient place Typical e DOOOOOOOOOOOOOOOOOA ood PHILLIPS HEAD 12 24 TYPICAL REAR DETAIL Figure 3 2 Rack Ears Mounting Installation 3 3 Figure 3 3 Wall Mounting 3 4 Installation Ambient Level Controller Connection With A LUUPAM Universal Paging Access Module The FM 15 ALC connects between the paging source PBX Key System or standard telephone and the paging amplifier see Figure 3 3 Universal Paging Access Module CAUTION Use only the i FM 14 Log Current Microphone MODE TT A standard microphone will be VOC PAR SUPPLY moves mm damaged if connected to the FM 15 CONFIRMATION TONE ao PREANNOUNCE TONE oo VOX DISABLE VOX ENABLE M EXT VOX ENABLE i PT PAGING OUTPUT 1 Ps vo aa CONTACT CLOSURE A PAGE PORT COM INPUT POWER SUPPLY 24 48 TRUNK ACCESS ONLY 24 48 AN O el vos oo MIN MIN MAX MIN MAX SWITCHES VOL TONE VOL VOX DELAY PAGING TIME CONTACT CLOSURE B NO COM 1 NOTE Loop start only Do not apply NOTE These terminals are redundant MIC input connections Useful when a Modular RJ 11 Plug and cable is not suitable Ring Voltage FM 15 o a Power Input ae In Mic Onh 24 Volts AC Loop Start SOSo Line Out to Page Input RCA C
8. ol up one click to the right clockwise 4 The PAGING LEVEL meter the Red LED paragraph see Figure 2 1 indicates the paging level changes that are taking place with dual LEDS 5 Calibration is complete Automatic Level Telephone Input Control Active Noise Level Paging Level Set Maximum Noise Level dB SPL dB B 100dB 105dB Full Volume 90dB 100d 95dB 6 dB 85dB 90dB 80dB o 70dB 60dB 105dB SPL meter Paging Level Maximum Noise Green LED Red LED Red Knob Figure 2 1 FM 15 ALC Manual Use of the FM 15 Ambient Level Controller The FM 15 ALC may be used without the FM 14 Log Current Microphone In this mode the FM 15 ALC becomes a leveler or limiter for manual control of the sound system The SPL meter will not function but all other functions will work in the normal manner The Manual Level Control on the front panel will set the level of the sound system see Figure 2 1 The Output Level Control see Figure 2 2 is preset at the factory for a 0 dB maximum output level The Enable Contacts see Figure 2 2 on the Line Input terminal strip when shorted with a DRY contact closure will produce an isolated DRY contact closure on the C1 and C terminals of the Line Output terminal strip Output Level Control Minus 12dB Jumper ran Line Out Q Line In Telco In Loop Start ce Output Level j Ac 900900 1 RT Line In Enable Line Output Enable
9. se see ee ee ee ee 2 3 FM 14 Log Current Microphone Hookup s ssssssssssssrssoossssrrsrssssrrersrrrnsrrrrrrrrssnrrnrr nns 2 4 Eed E Ee de N AE EE EE N 3 1 Power Supply FI OOKUP uses sesse see see ee ee gee eene ee ee ee ee en ee ee Gee ee oe ee ee Roe ee ee eene ee 3 2 Mounting Details Ge Ee ER Ge ERA DERE A Ge nns Aar Eora be se ASEE Saaai kke 3 3 Ambient Level Controller Connection With LUUPAM Universal Paging Access Module sesse sesse ses se eek se eek eek ee ee ee ee ees 3 5 Ambient Level Controller Connection With LUPCM Paging System uses see ee ee ese ee ee Ge eek ee Ge ee ee Gee ee ee ee ee ee ee 3 6 This page intentionally left blank Overview Contents Features Specifications Before You Start 1 2 1 4 1 5 Overview 1 1 Features 1 2 Overview Allows automatic manual or remote control of sound system levels It has an SPL meter with over 50 dB range built in The microphone can be placed up to 5000 feet from unit Simplicity in set up and operation Single rack space 1 RU Balanced 600 ohm inputs and outputs Line input activated by a contact closure Loop start TELCO input with priority over line input Clock inputs or remote control connections Relay outputs for emergency override or indicators Line output and a contact closure to supervise downstream equipment Internal microprocessor senses ambient noise via a microphone input and adjusts the paging level accordingly
10. ttach the AC power supply cord to building surfaces 7 DO NOT use the product near water or in a wet or damp place such as a wet basement 8 DO NOT use extension cords The product must be installed within 6 feet of a grounded outlet receptacle 9 DO NOT install telephone wiring during a lightning storm 10 DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations 11 Never touch uninsulated wires or terminals unless the line has been disconnected at the paging or controller interface 12 Use caution when installing or modifying paging or con trol lines Support Information Paging systems integrated with small phone systems such as Merlin Legend and Partner are supported by the National Service Assistance Center NSAC The main number for the NSAC is 800 628 2888 Paging systems integrated with large switches such as the DEFINITY G3 are supported by the Technical Service Center TSC The main number for the TSC is 800 242 2121 Contents Page Moe ER ER NE RR DE OO 1 1 El cavesstatvsnsvsnvsavesauey sass evianssas cavssansiwocnscvas taesvandenesseveavesesesevsseeugerel 1 2 Specifications lt teRewvads eta cise Ge ee nia na aaa See ee ee ee 1 4 Before You SET Ear i aa ANNA NA RAS KSR AS RENA ee ee 1 5 Mol n EE EE EE N 2 1 Front Panel S tup is slee ees Rise Bedek eg Ee os de ge DE oek eek ede Rg ge 2 2 Manual Use of the FM 15 Ambient Level Controller iese ses
11. urce 24 Volts AC UL listed power supply Maximum Power Consumption 60 Watts Frequency Response 250 Hz to 15KHz 2dB Signal To Noise dB ref Better than 60 dB Maximum Output Level 0 dB 12 dB with jumper Output Relay Trigger Points 0 dB and 6 dB gain reduction Output Relay Contact Rating 1 amp No of Relay Contacts 4 Input Level Controls internal 5 Control requirements DRY contact closure Input Types Line Telco loop start Output Types Line 600 ohm Contact Closure On Output Yes Contact Closure Controlled Input Yes Front Panel Controls Attenuation manual or automatic Front Panel Indicators Power Attenuation automatic Telephone input active REAR PANEL CONNECTORS Relays Compression screw Microphone RJ11 6 or compression screw Line In Compression screw Line Out Compression screw Telephone RJ11 6 Relay Outputs Compression screw Clock Inputs Compression screw Power Compression screw Microphone Type Electret omnidirectional Maximum Mic Line Length 5000 feet EE EE Table 1 1 Specifications Continued PHYSICAL Depth 8 3 4 inches Width 17 inches With Rack Ears 19 inches Height 1 3 4 inches Weight 8 pounds ENVIRONMENTAL Temperature Operating 32 to 104 F 0 to 40 C Humidity 0 to 85 Noncondensing Before You Start B

Download Pdf Manuals

image

Related Search

Related Contents

[December] [2010] Oracle Part Number E51712-01  Dataflex 88.065  Mode d`emploi  四管区水路通報第16号 - 海上保安庁 海洋情報部  取扱説明書 - のリズム  TRIAGE FORESTIER INTERCOMMUNAL DU SIGNAL DE BOUGY  120 babas bouchons pur beurre  Mode d`emploi Réservoir sous pression  MPX WIN 4.3 For use with Windows User Manual  R&S®EVS300 ILS/VOR Analyzer - Product  