Home
Integriti Graphic Keypad
Contents
1. lt MENU gt 7 2 5 See the Integriti Software Help or the latest version of the Integriti Programmer s manual for details Also refer to the Integriti Graphic Terminal User Manual for additional information on the default display Iconic and Text menu displays and the various Graphic screens for control information and programming operations
2. C 15 to 85 relative humidity non condensing 2012 Inner Range Pty Ltd Part No 636000 2 Integriti Colour Graphic Terminal Installation Manual Mounting template 88 mm 47 mm Position of LCD Display p Legend O Rear Casing mounting holes Tamper Lever mounting hole 132 5 mm 158 mm 85 5 mm Cable en try cutout 14mm 27 5mm 27 5 mm 55 mm 25 5 mm Rev 1 0 May 2012 3 Installing the Terminal Colour Graphic Terminal Parts List Colour Graphic Terminal assembly Installation Manual and mounting template This document Installation Choose an appropriate mounting location with a solid flat vertical surface and ensure that the LCD display will be at or slightly below eye level for all users a Remove the rear of the case by first applying gentle pressure to the lower locking tabs in the bottom rear of the case with a small flat blade screwdriver while gently pulling the lower front of the case away from the rear b Then gently pull one side of the front case away from the rear to release the upper locking tabs Check that the mounting surface is free from any materials or irregularities which may distort the case then mark the mounting hole locations Remember to insert the LAN cable and any other wiring through the cable entry cutout before fastening the rear casing to the mounting surface R
3. Rev 1 0 May 2012 1 Integriti Colour Graphic Terminal Part Number 996000 996000B Installation Manual The Integriti Colour Graphic Terminal is a User interface for the Integriti Hardware platform It features eight status LEDs a full colour LCD screen built in temperature sensor easy to read text and icon scroll wheel and function key based navigation system The colour and intensity of the Keypad backlighting and Screen colour schemes are configurable and feature auto dimming Audible indications are provided by sophisticated 8 bit digital sound tones and options are provided for Date Time and Temperature on the default display Graphic Terminals can be used in systems to perform programming commissioning and User operations display alarm messages and review system activity They communicate on the LAN as a Graphic Terminal Module Type and the module number and configuration options are programmed from the keypad Built in tamper monitoring detects any attempt to open the case or remove the product from the mounting surface Specifications Power Supply Input 11V to 14V DC Operational Current Default Backlight settings Low Ambient Light Approx 55mA High Ambient Light Approx 75mA Custom Backlight settings 50mA to 180mA Beeper Operating Add up to 65mA at maximum speaker volume level Physical dimensions Height 162mm Width 88mm Depth 15mm Enclosure material Polycarbonate Installation environment 0 40
4. and Maximum levels 3 2 Keypad Backlight Levels e Keypad Minimum Backlight level In very low ambient light e g A dark room e Custom Keypad Red Green and Blue levels NOTE These settings only relevant if the Enable custom keypad RGB option is enabled at Step 2 1 3 3 Keypad Colour Mode None Rainbow fast Rainbow slow Flame Water Random 3 4 Keypad Sensitivity Key sensitivity Use the lt DIGIT gt keys to test while making adjustments Scrollwheel sensitivity Use lt 4 gt and lt 6 gt keys to adjust and the Scrollwheel to test while making adjustments Use the lt 2 gt key to go back to Key Sensitivity adjustment 4 Resource configuration information The Integriti Graphic Terminal can have alternative sets of Image Sound Text String and Font resources At any given time one of each of these resources is in use in the device The Resource Configuration screen allows the Installer to view the Currently Loaded Resources files currently in use String and Font files will cater for different languages as they become available Image files will provide alternative sets of bitmaps icons and colour schemes Sounds files will provide alternative sets of sound effects At the time of writing this manual no additional resource files are available for the Integriti Graphic Terminal 5 Additional Graphic Terminal programming Other options are programmed in Graphic Terminal Programming
5. efer to Installation template supplied opposite Install the rear casing using three countersunk screws or bolts The Tamper Switch actuating lever may also be fastened to the mounting surface to provide an enhanced level of cabinet tamper detection Do not overtighten as this may cause the lever to dig into the mounting surface and limit its ability to actuate the Tamper Switch Connect the wiring into the Screw Terminal block See pages 4 amp 5 for details Position the three tabs at the top of the front casing into the slots at the top of the rear casing then gently press the two halves together until the locking tabs on the sides and at the bottom of the case engage 4 Integriti Colour Graphic Terminal Installation Manual Connections CAUTION Take care not to damage PCB tracks the components around the Screw Terminals or the LED light pipes at the top of the unit during installation LED Light Pipes TERM Not Fitted This link must NOT be T fitted on an Integriti T Colour Graphic Terminal ETX ERX Connection for field firmware upgrades and future expansion board LAN Connections See following page for information Rev 1 0 May 2012 5 LAN Wiring The LAN is connected using twisted pair fo communications cable Connect LAN A amp LAN B using one pair LAN amp OV with LAN OV LANA LANB ETX ERX another pair A amp B must be on the sa
6. lect the option to change b Press lt ON gt to enable or lt OFF gt to disable the check box type option c The lt LEFT gt amp lt RIGHT gt Arrows can be used to change the Colour Scheme d If changes are made press lt OK gt to save the changes and step to the next screen 2 1 Audio RFID future enhancement amp Custom Keypad Colour options e Audio auto off The speaker is muted when no audio is present to eliminate background noise This may be preferred in quiet areas e g bedrooms If enabled a short delay may occur between the re appearance of an audio signal and the speaker being un muted e Enable RFID ASK support Not yet available e Enable RFID HID support Not yet available e Enable custom keypad RGB If enabled adjust the RGB values in Step 3 2 2 2 Keypress options amp Factory reset e Enable red flash on error e Enable keypress flash e Reset all to factory defaults 3 Terminal Preferences 4 screens a Use the lt UP gt and lt DOWN gt Arrows to select the setting to change b Use the SCROLL WHEEL to change a level setting lt ON gt lt OFF gt for check box options c If changes are made press lt OK gt to save the changes and step to the next screen 8 Integriti Colour Graphic Terminal Installation Manual 3 1 Speaker LCD Backlight and LED level options e Speaker Volume level e LCD Minimum Backlight level In very low ambient light e g A dark room e Indicator LED Minimum
7. me pair Over longer distances use heavy duty Figure 8 cable for LAN amp OV or use a separate local power supply i Cabling distance should be no more than 1 5km from the Control Module a LAN Isolator LAN 2 or 3 Port or a Fibre Modem AB AB RS485 Port LY V gt LAN not connected if From To next Terminal powered from Previous module external Power supply module Auxiliaries and LEDs There are no physical Auxiliary outputs available on a Graphic Terminal Auxiliaries are used for the following indicator control functions G X01 Aux 1 Not currently used G X09 Aux 9 LED 1 G X02 Aux 2 Not currently used G X10 Aux 10 LED 2 G X03 Aux 3 Not currently used G X11 Aux 11 LED 3 G X04 Aux 4 Not currently used G X12 Aux 12 LED 4 G X05 Aux 5 Not currently used G X13 Aux 13 LED 5 G X06 Aux 6 Not currently used G X14 Aux 14 LED 6 G X07 Aux 7 Not currently used G X15 Aux 15 LED 7 G X08 Aux 8 Not currently used G X16 Aux 16 LED 8 Note Graphic Terminal programming LED Mode option must be set to Auxiliary LED Number 1 2 3 4 5 6 7 8 a OF inner range 6 Integriti Colour Graphic Terminal Installation Manual Access Control via a Graphic Terminal At present the Graphic Terminal can be used for Door Access Control in PIN Only PIN or Card or Card amp PIN modes to provide the PIN code entry Howeve
8. r the following conditions currently apply 1 The Graphic Terminal does not currently support any Inputs or Outputs Therefore the Door must also be associated with a Reader Module and all Inputs and Outputs associated with the Door must be connected to that Reader Module 2 The Lock Auxiliary for the Door must be the Reader Module Lock Auxiliary not the Terminal Lock Auxiliary Commissioning When installation is complete power up the Terminal The startup screen will display Waiting for LAN Connection along with the Module number Firmware Version and a lt Config gt Function key This screen is displayed for 30 seconds or until lt Config gt or lt END gt is pressed if Tamper switch is unsealed 2 5 seconds if the Tamper Switch is sealed e To view and or change the Module Number Set to 01 at the factory or the Colour Scheme press the lt Config gt Function key while this initial screen is displayed then go to Colour Scheme and Terminal Number below e To exit the startup screen and go to the normal default display press the lt END gt key If the Waiting for LAN Connection message is shown for more than 30 seconds the Module has not enrolled on the LAN This could be due to ALAN cabling and or connection problem Another Graphic Terminal with the same Module Number is already enrolled The number of Modules on the LAN exceeds the limits of the Memory Configuration or the licensing for thi
9. s Control Module When the startup screen closes the display may show a Terminal message Time Date Area status or Alarm message etc This means the Module Number has been accepted To change the Module number or Colour scheme you will need to enter the Configuration mode as described above To change other Graphic Terminal parameters you will need to enter Setup mode as described in Graphic Terminal Setup below Colour Scheme and Terminal Number a Enter Configuration mode as described above b To change the colour scheme press the lt Colour gt Function key b To change the Module Number choose a number that isn t already used by another Rev 1 0 May 2012 Graphic Terminal and enter the new number using the lt DIGIT gt keys Use the lt Delete gt Function key to backspace if you make an error Press lt OK gt to save the new Module number c Press lt Exit gt when complete Graphic Terminal Setup 1 Enter Setup Mode Logon with the Installer PIN code press lt MENU3 gt then Setup 7 key then Terminal 1 key At any time the following keys if displayed may be used lt Back gt function key Scrolls back through the configuration screens lt More gt function key Scrolls forward through the configuration screens lt END gt key Exits config and returns to the normal display 2 Terminal Setup options 2 screens a Use the lt UP gt amp lt DOWN3 gt Arrows or Scrollwheel to se