Home

USER MANUAL - Sky Elevator

image

Contents

1. Ky Elevator www sky elevator com www sky elevator com Skye evator A 422 CAL 22 DATA Sky 7 2 i kyelevat SKyY 401 MAIN CONTROL BOARD USER MANUAL V 2 0 SKY 401 USER MANUAL THIS DOCUMENT IS A SAMPLE FOR APPLICATION ALL INFORMATIONS CONTAINED IN THIS DOCUMENT ARE SUBJECT TO CHANGE BY SKY ELEVATOR WITHOUT NOTICE SKY ELEVATOR ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE LIABILITY OR OTHER LOSS ARISING FROM THESE INACCURACIES OR ERRORS OPERATION 6 TEMPERATURE 0 60 C PROTECTION CLASS IP20 SYSTEM INPUT 3 x 220 380V 50 60 Hz N CONTROL SUPPLY VOLTAGE 24 SV DC POWER CONSUMPTION MAX 300 mA 8W 24V DC SECURITY CIRCUIT VOLTAGE MAX 230V AC CONTROL SIGNAL INPUT 24 5V DC CONTROL SIGNAL INPUT WITH SHORT CIRCUIT 24 5V DC PROTECTION Sky Elevator ISTANBUL Tel 90 212 444 1988 CONTENTS 401 USER MANAUM D a 2 SKY 401 SPECIFICATIONS iy 4 EXPLANATION OF LES MELN AL SE yag 5 SKY 401 PARAMETER SETTINGS 6 AUXILIARY INPUT AND OUTPUT 65 7 SKY 401 PARAMETER LIS as era el Sara sasa S alsk 8 CAUTIONS F R PREMONLA Eu tali la sap tena le 10 CAUTIONS FOR MON PAG Bis u uu a al ya Sd emlak dpi ila 11 CAUTIONS FOR INSTALLA
2. Panel direction and motion connectors do not be closed by hand In such case security circuits can not block motion of the lift The 24V AC fuse on the card must not be shunted If the fuse blows constantly look for a short circuit at the shaft system and inside the panel Car lamp supply voltage 1F must be connected to the one of the main phases before thermic relay When motor calefacted the motor thermistor ends must be connected to the T2 connector to avoid the car stay between the floors Door frames must be connected to the grounding bar If grounding is not proper security circuits have a risk of shunted through door chassis After long time operations dust dirt oil can be affect the performance of the security system Please do not ignore plug and lock functions in periodic controls 14 Elevator www sky elevator com Ikitelli OSB Metal Sanayi Sitesi 19 Blok No 1 Ba ak ehir stanbul Turkey Tel 90 212 444 19 88 Tel 90 212 549 11 21 GSM 90 533 293 96 56 sky sky elevator com
3. Automatic Door Close Button common 100 Overload Indicator common 100 Out of Service Indicator common SCOM connector Busy Indicator common SCOM connector Down Indicator common SCOM connector Up Indicator common SCOM connector Digital Display Outputs 24V DC common100 Auxiliary Input common100 Digital Common 24V DC 24V DC Simple Control Common Automated Door Close Signal common K15 Automated Door Open Signal common K15 K3 K5 Common Input Auxiliary Relay Contact Auxiliary Relay Contact 5 SKY 401 PARAMETER SETTINGS 1 Press the enter button to enter the parameter settings menu 2 Press up or down buttons in order to find the desired setting 3 Press enter button to change the value of the desired parameter the chosen parameter is going to be blink set the parameter to desired value by using up and down buttons Gif you don t want to store the value in memory press escape button 4 After setting the parameter value press enter button to memorize it then it passes the next parameter 5 Press escape button to exit from parameter settings menu EXAMPLE Setting the stop number Press enter button to enter the parameter setting menu Press button until find stop parameter Press enter button again stop number will blink Choose the stop number using the up and down buttons Pres
4. time with power contacts The bridge diode connections of the brake and pump must be done according to the schema and must be used isolated lugs Panel manufacturer must control all the connections and do the required tests after finishing the panel 10 CAUTIONS FOR MONTAGE The connections between the control panel and motor car and lift shaft must be done carefully according to the SKY 401 schema The 3 phase supply voltage must be connected to the R S T connectors on the panel with suitable fuse chose due to motor power and network neutral must be connected to the MP connector Grounding cables and neutral must be separately connected and the panel body must be perfectly grounded All stopper linkages specified in EN 81 1 2 standards must be placed in lift and the connections of these linkages must be done to the control panel according to the SKY 401 schema All the used contactors must be convenient to the EN 60947 standards CAUTIONS FOR INSTALLATION OF CONTROL PANEL Be sure that the connections between the control panel and lift system are done according to the SKY 401 schema Control if there is any short circuit in the connections with a suitable measuring device Take the control panel revision switch to ON position Take the motor protection circuit stopper to ON position and turn on the panel electric Control that the led of 02 on the board and out
5. be exact convenience of the lift system to the EN 81 1 2 standards as electrically the control card control panel security circuit and electrical connections must be convenient to concerned standards The producers whom willing to build panel with SKY 401 must have enough level of information and experience about EN 81 1 2 standard and other standards regulations and instructions SKY ELEVATOR assumes no responsibility for panels not build towards the given directions SKY ELEVATOR guarantees that SKY 401 is convenience to the EN 81 1 2 but inside and outside connections of the control panel and other electrical connections are under responsibility of mounter There must be 10mm distance between the SKY 401 control card and the panel The SKY 401 control card must be fixed from 4 holes at the edges After the puncturing to place SKY 401 card and other components in the panel the panel must be cleaned very carefully from iron pieces and conductor wires otherwise these pieces can be cause damage while transferring the panel from somewhere to another The contactors that are used for the AC motor lifts must be chosen according to the EN60947 AC3 class and must be enduring for the motor power The connection must be done according to the directions shown in the SKY 401 schema The cooperative motor placed on the main contactors must be chosen according to the EN60947 and must be controlled that contactors are active inactive in the same
6. of service lamp on the floor buttons are light up Control that the voltage between the 100 1000 connectors is 20 26V DC Be sure that all security contacts are connected according to the schema and operates correctly Control the security inputs activity from 120 130 140 leds The revision switch on the control panel is in ON position so the car will operate only at low speed Control that the low speed coil is correctly coiled by routing the car with the up and down buttons placed on the control panel If the car goes to wrong direction change place of any two ends U2 V2 W2 of low speed coil on the control panel Measure the voltage between 2001 810 and 2000 840 connectors while car is in motion The value must be in 180 240V DC interval Place the on one of the middle floors and take the car top revisions switch to OFF position The Out of Service indicators will turn off on the floor buttons Be sure that the lift going the true direction by giving log call s if it operated wrong change place of any two connections U2 V2 W2 CONTROL AND CLEANING Does not reguire periodic control In case of a problem sent the card to the producer firm for control and fix Do not connect to the liquid materials If needed clean with pressured air RISK ANALIZE The contactor connector 11 on the SKY 401 card must be connected to the security system turning
7. TION OF CONTROL PANEL 12 CONTROLAND CLEANING auqa baa ez ime kz 13 RK N AZE a e ii a e al elle 14 SKY 401 SPECIFICATIONS Simple and mixed collection Adjustable stop numbers Parameters can easily adjust with program buttons and LCD screen Overload function Full load function Minimum load function Heading towards to first predetermined floor in fire case Adjustable parking station and travelling time Full short circuit protected log call inputs overheating overcurrent overvoltage protected To all log call outputs 1A lamp can be directly connected Adjustable display output according to the intended code for each stop When the doors open for a long time giving out of service signal to outside buttons Choosing open close waiting position of all or each floor for full automatic doors According to EN 81 1 2 standard closed waiting must be chosen Adjustable waiting on the floor lock waiting busy time automatic door on off positions max high speed max low speed times Automatic door card is placed on the main board no need to use another board Operating in revision mode chosen by program buttons Adjustable time delay relay for speed controlled lift Programmable auxiliary relay Programmable auxiliary input Programmable position reset When one of the log call buttons hang up the car waits for 1 min on
8. atic doors PARAMETER SETTING LIMITS FACTORY EXAMPLE VALUE Time to go to the park floor PARK TIME 3 995 after turn off the busy indicator LOCK TIME 5 15 After pump pull lock will wait upto the chosen value DISPLAY 00 01 02 03 04 05 06 07 0 00 01 02 03 04 05 Floor information shown on SETTINGS 8 a b c d 1 1 2 3 06 07 08 the display this parameter must be FLOOR DOOR chosen wait closed for SETTINGS capability to the EN 81 1 2 standard time settings display settings Chosen open close state for automatic doors must be set separately at thefloors FACTORY floor d tti SETTINGS floor door settings general settings all settings If there occurs a problem in any inputs on the card due to any reason the GP1 AUXILIARY BOS 2 142 817 818 connector can be set in the INPUT M1 KG 869500 5001 place of failed input and SETTINGS DTS K20 after doing the necessary settings in the parameters menu card will continue its normal operation Used to return to the factory v all desired parameters if there occurs a problem in any relays on the card due to any reason the YED1 and YED connectors can be set in the place of failed relay and after doing the necessary settings in the parameters menu card will continue its normal operation AUXILIARY BOS RU1 RU2 RH RF OUTPUT LIR KLR OTO 031 032 SETTINGS 12 02 CAUTIONS FOR PREMONTAGE In order to
9. s enter button to memorize the value and pass the next parameter setting AUXILIARY INPUT AND OUTPUT SETTINGS There are o 1 auxiliary input o 1 auxiliary output relay existing on the board for general purpose Auxiliary Input GP1 If there occurs a problem in one of the inputs on the card T2 142 817 818 M1 KG 869 500 501 803 804 805 K20 DTS as a result of any reason such as short circuiting or wrong wiring change the parameter input with the auxiliary input GP1 without moving the card out of the panel After this change the card will continue its normal operation EXAMPLE If the 142 input failed Put off the wire of the 142 connector on the card and put the same wire on connector Enter the parameter settings menu and come to the aux input sel parameter Press enter button set the aux input value as 142 by using the up button Press enter button to store last change in the memory After this setting the GPT input will operate as 142 input This process can be applied to the all inputs on the card Auxiliary Output YED If there occurs a problem with one of the relays on the card RU1 RU2 RH RF LIR KLR AUTO 031 032 01 02 12 this auxiliary input can be used instead of the broken relay EXAMPLE If LIR relay is failed Change the wire of P1 connector with the one of the YED connector and the
10. this floor then cancels this floor and continue its normal operation until the short circuit will be eliminated Meanwhile a warning will be displayed on the LCDscreen Overheating overcurrent overvoltage protected display and log call outputs R S T MP N U V W U1 V1 W1 10A 11A 110 120 130 140 1F 1 2 810 amp 2001 840 amp 2000 401 416 142 817 818 803 804 805 KK 869 500 501 1 K20 DTS 1 2 12 31 32 a b c d e f g 2g GP1 24 100 1000 190 K3 K5 K15 YED YED EXPLANATION OF TERMINALS System Main Phases Neutral Fast Motor Outputs Slow Motor Outputs Security Circuit Neutral Security Circuit 140 Turning Contactor Coil Voltage Security Circuit Supply Security Circuit Stop Turns Security Circuit Door Turns Security Circuit Lock Turns Phase direct connected to the one of the system main phases Car Socket Voltage 220V AC Car Lamp 220V AC Pump Brake Car Call Button Inputs and Lamps common 100 For Two Speed Systems Level Stopper Magnet common 100 Lower Level Stopper Magnet common 100 Top Level Stopper Magnet common 100 Min load Contact common 100 Overload Contact common 100 Full load Contact common 100 Contactor Feedback common 100 Revision Switch Input common 100 Revision Down Input common 100 Revision Up Input common 100 Magnet Switch for Floor Selection common 100 Automatic Door Open Button common 100
11. wire of P2 connector to the other YED connector In the parameter settings mode find the aux output sel parameter and press enter button Choose auxiliary output as LIR by using up button and memorize it by pressing enter button This process can be applied to the all relay outputs on the card SKY 401 PARAMETER LIST PARAMETER SETTING LIMITS FACTORY EXPLANATION PANEL GET Be operated at inspection INSPECTION mode on card STOP NUMBERS 16 Adjustable stop number simple collection simple control COLLECTION TYPE mixed collection manual DOOR TYPE half automatic full automatic one speed OPERATION TYPE two speed Vvvf speed speed control MAGNET STRING M1 counter M1 counter encoder PARK STOP Choose 9 to cancel park stop CHOOSE directly stop INSPECTION go to the floor directly stop SWITCH no resetting Reset operation after power POSITION RESET resetting no resetting cut Choose 9 to cancel fire stop WAITING TIME ON Time to go to the next floor THE FLOOR 2 58 after stopping on a floor Max motion time betvveen FAST TIME 5 99s two floors at fast speed Max motion time between SLOW TIME 5 405 two floors at low speed Car lamp and turning on BUSY TIME 2 40s time of 12 Set the value according to CLOSE DOOR TIME 2 15s NI NI 3s 10s 10s 10s the door width for automatic doors Set the value according to the door width for autom