Home
Ropox Shower & Changing Bed
Contents
1. N User Manual must be read before use E Waste must be sorted Most parts for re use Tt Type B equipment As for EN 60601 1 E Class 2 equipment Without earth connection CE CE marking This product complies with the demands for general safety and functionality in the relevant EU directives and standards EMC information The shower bed complies with the demands for electromagnetic compatibility EMC if installation and daily use is according to instructions in this Manual In seldom situations the Shower bed might be affected by electronic signals from ex Portable computers cell phones etc Page 21 Support Fault finding The bed does not move up or Check if down by when operating Main power connected 230V using the hand control Motor is connected to control box Hand control is connected to control box Motor is overloaded Hand control defect Check if The product works with another hand control By pressing the up or down Plugs are not connected correctly button no movement is Dismount all cables and re connect achieved only clicking sounds is are heard from control box Waste handling Used equipment shall be disposed of according to the National law We recommend to dismount the product to the greatest extent possible in a way that most parts can be reused Be aware that this product contains electronically components Example of groups this product can be sorted in metal plastic cables elec
2. Important Do not use scouring powder or other abrasives as they may scratch the surface Also avoid the use of cleaning utensils with sharp edges Never use strong mineral acids or alkali Page 25 CE erkl ring EU Declaration of Conformity Ce hereby declare under sole responsibility that the following products 40 25023 Ropox Shower amp Changing Bed 146 cm 40 25026 Ropox Shower amp Changing Bed 178 cm 40 25029 Ropox Shower amp Changing Bed 210 cm are all under Classification Class and in conformity with the following directives and standards DIRECTIVES e The Council Directive No 2007 47 EEC concerning Medical Devices amended through Directive No 98 79 EC e 2006 95 EEC Directive for Low voltage amended through Directive No 93 68 EEC e 2004 108 EEC EMC Directive amended through Directives No 92 31 EEC and 93 68 EEC STANDARDS DS EN 1041 2009 DS EN ISO 10993 1 2009 DS EN 14971 2008 DS EN 60601 1 CORR 2006 DS EN 12182 2002 DS EN 60601 1 2 2007 DS EN ISO 9999 2009 Dato 01 05 2011 m direktor Page 26 Complaints See General Terms of Sale and Delivery on www ropox com Page 27
3. adjustment of the shower bed can be performed Part Numbers Length of shower bed PAEO 146cm 40 25023 178cm 40 25026 210cm 40 25029 Page 3 General information Technical data Electrical connection 230V 50Hz max 2 0A Standby consumption 7W Duty cycle Max 10 2 min 18 min Height Work surface 30 100 cm Unit B 60 cm H 116cm D 13cm Material Frame Welded steel tubes St 37 Stainless and aluminum Shower tray ABS Surface treatment Powder coating white RAL 9010 matt Chromate Maximum load 150 kg This product has CE marking according to Medical equipment Low C 4 Voltage and EMC directives Has been tested according to the European standards DS EN ISO 12182 and DS EN ISO 60601 1 This product is in risk group 1 Daily use Before start using this product be sure that main power has been connected as described in electrical connections By using the up A down Y bottom on the handheld control switch the height adjustment of the shower bed can be performed The control switch has a spiral cord which can be pulled out to a length of 200cm Maximum load onto the Shower amp Changing Bed 150 kg The slat The slats have two sides with different hardness and can be turned around in the Shower tray The soft side is used when the person on the Shower bed needs to be washed The hard side is used when the person on the Shower bed needs to be changed Page 4 General info
4. has been damaged or stopped working it has to be replaced immediately The up and down buttons are push and hold The motor stops when the button is being released This is a very important safety element If two shower beds are mounted next to each other we recommend to mount a side cover between to avoid the risk of trapping Constantly be aware of objects under the shower bed Page 6 Mounting Instructions Important info before mounting Make sure that you allow free space on all sides of the unit as shown below showerbed type 40 25023 166 cm type 40 25026 198 cm type 40 25029 230 em 60 127 cm MUST be free space Water Hot and cold Drain Placement of the Main 230 V socket the hot and cold Water and the Drain The drain and the hot and cold water must be placed in the free area beside the lifting unit Make sure that the Main 230 V socket is placed according to the national requirements for such installations Page 7 Mounting Instructions Receiving the Shower amp Changing Bed The Ropox Shower amp Changing Bed will come in two packages One for the Lifting unit and one for the Shower tray unit Lifting unit Shower tray It is important to follow the mounting instructions to assemble the unit in the right way and to obtain a safe product Page 8 Mounting Instructions 1 Prepare the mounting dismount the top cover plate Pull up the cover plate on
5. the top of the lifting unit to get access to the nut which holds the front plate Loosen this nut Page 9 Mounting Instructions 2 Prepare the mounting dismount the front plate Slide the front plate out of the Lifting unit to get access to the wall mounting holes in the unit Be aware not to bend or scratch the front plate in the process 7 E Page dO NS _ Mounting Instructions 3 Mounting to the wall Attach the frame securely to the wall by using adequate bolts and rawlplugs suitable for the type of wall construction material on site The Shower bed is being supplied with a set 8 pcs of screws and rawlplugs which is ONLY used to mount the unitin a concrete wall If the unit must be mounted on another kind of wall other kinds of plugs and screws must be used Shower bed is tested according to a load of up to 150 kg applied to the shower bed If you have other objects mounted right next to this shower bed you have to consider the risk of trapping and therefore consider a safe distance to the other objects The attachment holes can be marked up on the wall four possibilities in the top and four in the bottom of the frame Place the frame against the wall and make sure it is horizontal The frame is standing on two adjustable feet The holes in the frame are all 10 mm Remove the frame and drill the holes Make sure that no dust or other obstacles are interfering with the rollers c
6. tube and connect it to the drain in the wall or on the floor e After mounting make sure that the chain is in correct position on the sprocket also check that cable plugs is connected correctly to the control box e Check that no cables can be trapped or squeezed e Connect the main power and the shower bed is ready to be used Page 18 Electrical components Wire diagram The shower bed is delivered with the control box already mounted on the frame The diagram shows how the cables which are connected to the control box All the plugs are water tight and therefore they can be a little tricky to connect disconnect Make sure that the plugs are positioned correctly before they are pushed into the sockets at the control box The plugs must be pushed into the sockets until the O ring is no longer visible Motor control box and control switch apply to IP66 This means that they are dust tight and protected against heavy seas or powerful jets of water The electronic system is designed for periodical use only this means a max duty cycle of 10 2min on 18min off q Control box Mains cable 230V Motor connects to socket 1 Ls End plugs connects to socket 2 3 amp 4 Hand control connects to HB socket ee a Page 19 Electrical components Connecting cables The shower bed is delivered with the control box already mounted on the frame Motor cable connects to socket 1 Socket 2 3 amp 4 a
7. ED AATDAN RUI UA CE Better ways to better days Ropox Shower amp Changing Bed User Manual Mounting instruction Keep this folder with the product at all times PDF6051 19 12 2013 Content PrOduCE information veesseccsecnovsnteassspccaesesetnasusascueanepatuasseneteedsnaosuesnseatcosswensaewnsentwecstentseavees teases RNA ON a E 3 Part NUMPES scio aaa dad co ds Ends an ias Dea En Usp nada Dada cantar umeasemnceneareuaevuccnaceeantunuseuseuncavecreuaesuccueseesseue 3 Tecnnical CALA sc Dadas Gandna scanec ax agentes As SG ada sagas a a siDads Sands nas can s 4 DANOSO A sos nin A E E E A DS DS E 4 EG c o E E A A E A DRE SR RD ER RE RS 4 PAN ic QUO jo cn sta REI RR GERA RAD A RE OO CORE UR CSPE O E GEES AR SERES GRADE QU RE IES E 5 RecoOmmendations IN USE jesus capisisasinsdiaio dass dr saindo so da isds eins diaio dass EUEN EA EEE EE ia 6 important info before mountInE ssusaiiassseipanisoiiadincedssadaaabisddada dign sceligdinco ANNONE ENNES 7 Placement of the Main 230 V socket the hot and cold Water and the Draiin ccccscscscsscsccccscsccccsccccccsceccccsces 7 Mounting INSTRUCTIONS sscapaaiade ansiosos ia ads adorada esa id danado daiane ada a dns iai dessa dei fda sanada andar 8 Receiving the Shower amp Changing Bed sesessssesecececsesesecececsesesecececsesesesececeesesesececscsesesececscsesesecececsesesececeeseseseceee 8 1 Prepare the mounting dismount the top cover plate sss
8. RO RS RETRO RR 22 Waste Danding a sessesissaguridoriiaadisiico ncia sadios aii aa adia i estica sadia S 22 Factors affecting the operation ssessssesessececseosssecsesecsssecseseosesecsesecsesecssseosesecsssecseseosesecsesecsesecsesecseseoseseosesecseseoe 22 Factors affecting storage and tranSpoOrt csccsccssccscceccecccsccecccsccscceccesccscceccuscscceccescescceccescscceccescossceccescessceccesss 22 SPIEDO S aea NEEE EEE EEA EEE EE 23 ACCESSONES a aE E E E E EEN EE E E EET E 24 Bed DUO r O E 24 Maintenance sa EEE E E E E EE E S 25 CICAME aa 25 CEEI ET e O E EE E A E A A cs 26 EU Declaration of COMIOPINIEY seeteicecectedecadutaccecexcadecadetadcacaseceusdatedscduntaraccdutadceaestedenatuseccucdmtadeesdutacsecextenaeaaeteccsaenee 26 COO fo q S RAN DN PRP RO DR RE E E PERO RR DN OS SD ER E E RO 27 Page 2 General information Product information A N It is important to read this manual before mounting and daily use Product Ropox Shower amp Changing Bed height adjustable Producer Ropox DK 4700 Naestved Phone 45 55 75 05 00 Usability The height adjustable shower bed can be used to nurse children and adults up to 150Kg The shower bed can be used at home in day care center or institutions to obtain good and correct working conditions for the carer When not in use the shower tray can be folded up against the wall to save space By using the up and down button on the handheld control switch the height
9. hain sprocket or gas springs This can cause malfunction and damage the system Force for each of the four screws in top of the unit Fscrew 150 kg 923 1122 4 screws Fccrew 31 kg for each screw Page 11 i E a am p No l Mounting Instructions 4 Remount the front plate Slide the front plate back into the Lifting unit and fasten it with the nut Page 13 Mounting Instructions 5 Mount the shelves on the Lifting unit Use 4 pcs M5x10 screws to mount the shelves on both sides of the lifting unit Page 14 E E E Ta Ar Frar An TRAMA EFTE er trav on tne l S SA ty O BR UBEBW BAIRAWA j J E O Slide the Shower tray in between the Lifting unit and the support arms on the Lifting unit D aaa 1 e Mounting Instructions Fasten the Shower tray to the Lifting unit with 8 pcs M8x16 through the bushings in the support arms Page 16 Mounting Instructions 7 Mount the cover plate on Shower tray Place the cover plate between the two support arms underneath the Shower tray Fasten it with 4 pcs M5x10 Page 17 Mounting Instructions 8 Mount the Drain and Flexible hose on the Shower tray Screw the plastic nut on the scuttle and tighteen it firmly Connect the flexible hose to the drain
10. re not in use and are blocked Control switch connects to HB When all cables have been connected use the safe locking bracket Pushed in until you hear a click Mains cable connects to the socket at the side of the box Disconnecting cables Mains cable can be pulled out no safe locking bracket Before the other cables can be disconnected the safe locking bracket needs to be released removed use a screwdriver to remove Locking clips at each end of the safe locking bracket have to be released before the bracket can be removed and the cables can be disconnected To obtain the full IP66 value it is very important that all the plugs have been pressed firmly into the sockets and the safe locking bracket is mounted Placement of the handcontrol Bracket for hand control can be placed at the wall as shown To be mounted with the two screws which are delivered with the bracket 3 3 3 3 Hand control should be placed out of the reach of children Page 20 Labelling Label Each shower bed has its own label as shown The label contains information which is very important to specify when contacting your supplier It also shows main power supply DK 4700 Naestved Phone 55750500 Item No Serial No e ROPOX A S seRrIAL NO xxxx a 40 25026 Name gt Showerbed 178 cm model a SOM l CERARISN See explanation below Production year amp Max load 150kg month Symbol view
11. rmation After use When not using the shower bed the shower tray can be folded up against the Lifting unit This way it will only take up the space of approx 30cm from the wall Inside the lifting unit a gas damper is mounted to reduce the power needed when folding the tray up and down Page 5 General information Recommendations in use The height adjustable shower bed helps the caretaker to obtain the most optimal working height Height adjustment allows you to customize the working height to the individual carer and can also save unnecessary lifting when transferring from e g wheelchair To ensure optimum utilization of the shower bed features and avoid accidents it is important to observe some basics safety procedures NEVER leave a person on the shower bed unattended not even for a very short period The shower bed must be operated only by adults Pay particular attention to other people in the room when using the shower bed Make sure that no children are playing under or with the shower bed Keep the hand control out of the reach of children Make sure that they cannot operate the shower bed unattended A bracket for wall mounting is included with delivery Make sure that there is free space above and below the shower bed to allow height adjustment The shower bed is upfoldable but please be aware of obstacles above below and around the shower bed to prevent risk of trapping If the control switch
12. ssssesosesosssosssossesssesosssosesosssosssosseoosesssesosssosseosseesseesses 9 2 Prepare the mounting dismount the front plate scccsssccssscccssscccescccescsccescecccceceseccuseseceseseuscsecseseceseesecs 10 3 INIOUN EINE tothe A a 11 A Remou nt th front plate sccesssaasiesecenccesecesteanviecetuanierteesvounsieusieutneswesaesaubseus ENNEN EAS E ENEE KOENEN 13 5 Mount the shelves on the Lifting unit ssesessessssecsssecsssecsssecsscecssseosesecsesecsesecsssecsssecsesecsesecsesecsesecsssecsssecssseoee 14 6 Mount the Shower tray on the Lifting unit ssesessessssecsssecsessecssseceoseceosecsosececseceosececsececseceoseoeoseceeseceosesesseceeseo 15 VIRE GA SRA S 19 COMMCELING CAES im ir ia a 20 Disconnectine CANDIES disdicssssuancevcntcsccrecseacessssascreiveaseiwansaacsasuuscisssedcuseacoasiinsibadunasunssuuadtencurssseasisettosantseenaaueaautuabeseis 20 Placement OF TNE handcontrol icsscccacessesssceccessacsaaeccssnecsenncancccscanasexnunanesescscasexansoetsussssnaceaesoenenscentinesanaccesscnsanenaianess 20 EOWA ais capi atada cantar O o Rd a A ao IS RO E de 21 Bs o RARAS a OA CORRS O bates ut oa A SS SRA SO ORAR RARA A AURA ARA ASIA eee ee 21 SVO ADE a a tneraeetancesevtocecaustauerswiliannaustanaaetiavectectauesseseaenapetauaniatianacdentancsseecieecaustauneidiiuanauabaneuieciaueeseces 21 SUD OOM a DERRADEIRA RE SPEEDS OR DRE SRA RR DRE NOR RR E ORDER AR A A DAR 22 REM Cole o o corean DRA RR ROGER CR ERR ER
13. tronics and parts for destruction Factors affecting the operation O Temperature 0 C to 40 C Relative humidity 5 to 85 non condensing Factors affecting storage and transport ers Page 22 Spareparts Spareparts 97000431 Actuator motor Type LA34 5 Stroke 350 mm 97000434 Control Box Type CB6096 2 97000425 Hand Control Type HB8195V0001 61 40 40090 180 40 40090 315 Flexible plumbing kit Page 23 Accessories Bed guard Bed guard is available as an option The brackets will be mounted underneath the frame with the screws supplied Length of Shower bed Bed guard foldable Bed end guard Shower bed L 126 cm Fixed 40 25023 40 25036 40 25038 40 25026 40 25036 40 25038 40 25029 40 25036 40 25038 Page 24 Maintenance The Shower amp Changing Bed is maintenance free For safety reasons it is recommendable to check all mounting screws and moving parts to be sure all is tightened ok and that all attachment to the wall is in correct and safe condition Cleaning To clean this product do not use a high pressure washer Simply use a soft cloth or sponge with soapy water pH 7 of max 60 C Always clean this product after use to prevent dirt from sticking to the surface Disinfection Only use water based disinfectants when disinfecting the slats Alcohol and chlorine based disinfectants can discolour the slats Avoid cleaning the foam slat with household spirit as this can discolour the slat
Download Pdf Manuals
Related Search
Related Contents
Biostar G41D3+ motherboard INSTRUCTION MANUAL TEN Group Rail Catalogue Sony CLM-V55 Operating Instructions Philips TP2781C 27" TV LEDG85030 Copyright © All rights reserved.
Failed to retrieve file