Contents

1. sub menu press T to exit main menu operation and return real time IR mode Function operation Thermal camera focusing To motorizedly focus Aim the lens at the target F Press 4 to activate the menu Press the softkey labeled Far and Near until the image on the LCD is as clear as possible Image capturing and saving Aim the lens at the target of interest and adjust the focus motorizedly or automatically above to get a clear image on the LCD and then pull the trigger to capture an image The image will be frozen and bring up the image capture menu Press the softkey labeled Save If the SD card is in the camera the image data will be acquiescently saved in the SD card Selecting the Palette Press J to display main menu Press the softkey labeled Parameter Press the softkey labeled Palette MZ PJ Press amp to confirm to shift among different palettes Setting Tmin and Tmax P Keep depressed for 3sec to display the menu passes me 10 User Manual Al 4 u eu k2 P J Press to increase the Tmax value press Y B to decrease the value press to switch to Tmin adjustment mode The same operation for Tmin adjustment F Press 3 to enter Auto mode and Tmin and Tmax will adjust automatically according to the change of scenery Reviewing and Deleting Stored Images To view stored images on
2. the SD card y activate the menu Press the softkey labeled File to reveal the review menu Filelist Press the softkey labeled OK to enter the file list Press the softkey labeled and gt to toggle between different images and press the softkey labeled Select to choose the selected image To delete a single image from the SD card Perform the steps under viewing stored images above to bring the desired image to the display Press the softkey labeled Delete Press the softkey labeled Yes To delete all the images from the SD card Press to activate the menu Press the softkey labeled File Select Del All by pressing softkey labeled and and OK to confirm Press the softkey labeled Yes Listening to Voice Annotation To play the voice annotation already stored with an image on the UFlash or SD card Perform the steps in the Reviewing and Deleting Stored Images section to bring the desired image to the EASIR 0 s display Press the softkey labeled Voice Press the softkey labeled Play The saved voice annotation will be replayed through the imager s speaker 11 G aide User Manual Changing the Temperature Units The EASIR 0 will display temperature in Fahrenheit or Celsius To change the temperature units M o Press to display main menu Press the softkey labeled Setup Press
3. GUIDE EasIR 0 Thermal Camera User Manual Wuhan Guide Infrared Co Ltd No 26 Shucheng Rd Hongshan District Wuhan 430070 P R China Telephone 4 86 27 8767 1991 Facsimile 86 27 8767 1927 Email overseas guide infrared com Internet www guide infared com Wuhan Guide Infrared Co Ltd 2012 Publication No GUIDE EASIR 0UM 012 The Quality Management System of Wuhan Guide Infrared Co Ltd is approved to ISO9001 2000 for the design and manufacturing stockholding in house repair and site servicing of non contact temperature measuring instrumentation Wuhan Guide Infrared Co Ltd reserves the right to make changes and improvements on any of the products described in this manual without prior notice GUIDE EASIR 0 Thermal Camera complies with current European directives relating to electromagnetic compatibility and safety EMC directive 89 336 EEC Low voltage directive 73 23 EEC Copyright Wuhan Guide Infrared Co Ltd 2012 All rights reserved worldwide No parts of the products may be reproduced transmitted transcribed or translated into any language or computer language in any form or by any means electronic magnetic optical manual or otherwise without the prior written permission of Wuhan Guide Infrared Co Ltd This manual must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without prior consent in writi
4. bolometer 160x 120 pixels 25um Spectral Range 8 14um Thermal Sensitivity lt 100mk at 30 C Field of View Focus 20 6 X 15 5 11mm Focus motorized Image Presentation External Display 3 6 TFT LCD with high resolution Video Output PAL NTSC Man Machine Communication Buttons Respond as per operators operation Menu Microsoft Windows style Measurement Temperature Range 0 C to 250 C Accuracy 2 C or 2 of reading Emissivity Correction Variable from 0 01 to 1 00 in 0 01 increment Measurement Features Automatic correction based on distance relative humidity atmospheric transmission and external optics Optics Transmission Correction Auto based on signals from sensors Image Storage Type Removable 2GB SD card File Format JPG with analysis records Power System Battery Type AA rechargeable battery field replaceable AA Alkaline battery also usable Charging System in battery charger Guide Battery Operating Time User Manual Over 2 hours continuous operation External Power Operation AC adapter 110 220 VAC 50 60Hz Environmental Specification Operating Temperature 0 C to 50 C Storage Temperature 10 C to 60 C Humidity Operating and storing 10 to 95 non condensing Encapsulation IP43 Shock Operatio
5. dhered to at all times Non optical surfaces The non optical surfaces of the camera can be cleaned when required with a soft cloth dampened with water and a mild detergent Optical surfaces The optical surfaces of the camera lens should only be cleaned when visibly dirty Care should be taken to avoid touching the exposed lens surface as skin acid left behind from fingerprints can be damaging to coatings and lens substrates Use only a proprietary lens cleaning tissue Guide User Manual Calibration and Repair Philosophy To ensure the accuracy and reliability of the GUIDE EASIR 0 Thermal Camera it is highly recommended that the instrument be calibrated at 12 monthly intervals Calibration or repair for the instrument can be obtained by either contacting the address telephone number on the cover of this User Manual or by email to the following addresses overseas guide infrared com Caution The GUIDE EASIR 0 Thermal Camera does not incorporate any user serviceable parts Never attempt to disassemble or modify the camera Opening the unit invalidates the warranty Technical Support Technical support for your Wuhan Guide Thermal Imaging System can be obtained by either contacting the address telephone number on the cover of this User Manual or by email to the following address overseas quide infrared com Feedback to Us We have tested and verified the information in this manual to the best of our abilities Yet as we ar
6. e committed to continuous development and progress you might find features of the product have been changed since the time of printing You are appreciated to let us know about any error you find and your suggestions for further editions by either contacting the address telephone number on the cover of this User Manual or by email to the following address overseas quide infrared com System Overview GUIDE EASIR 0 is a new infrared camera of Guide infrared breaks the IR world with its lowest price and high performance Designed for tough work environments and entry level users EASIR 0 is far more robust and shock resistant for any tough working environment and it is easy to operate and allows for the learners to operate without being trained and take the inspection work easily with one hand Featured with latest IR Fusion technology it helps you pinpoint the problem exactly with the most efficiency Power on the EASIR 0 let the 3 6 LCD bring you into the fresh IR world System Configuration Please ensure that the following items have been correctly supplied e IR Camera with visual camera 11mm IR lens e 3 6 TFT LCD with high resolution e 2GB SD card amp card reader e AC Adapter amp cable USB extension cable Guide e USB driver e Guide IrAnalyser Software User manual Options e Sun Shield User Manual Technical Specification Imaging Performance THERMAL Detector type Uncooled FPA micro
7. e lowest limitation the red indicator will flicker for a moment then power off automatically M Y Note When using the battery only when powering on and in the low battery condition the indicator will light on How to charge with batteries Charge the batteries with battery charger only v Note Please choose qualified rechargeable batteries and battery charger Buttons Introduction CER jel There are three functional buttons of GUIDE EASIR 0 From left to right they are r and O and a trigger button T Power on off the camera M The input voltage is 9V keep button depressed for more than 3 seconds to power on When powering off keep M Zo J depressed until the switch off bar runs fully To release the button at any time before the the button Y switch off bar runs fully to leave the power off state Focus F In the non menu state press 4 to enter focus menu the following info will be displayed on the screen n ES According to the attention press 4 to focus far press amp focus near Press Tor Quick function G aide User Manual pj In the non function state long pressing the to switch between the manual mode and automatic mode and pj press amp shortly to enter spot analysis mode L R U D P jJ Press to switch between the up down or left right ET M Fo Press or to adjust the value of X or Y s coordinate Press T to ex
8. he Guide IrAnalyser software Install USB driver to PC When there is no menu in the live thermal image properly connect the USB interfaces of the camera to a USB2 0 port of your PC with the USB extension cable Microsoft amp Windows launches a Found New Device Wizard to guide you to install the driver as follows e Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for USB Device lf your hardware came with an installation CD E92 or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue Choose Install from a list or specific location advanced and include the folder where you save the driver program Then Click button next to go further 13 User Manual Please choose your search and installation options Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed C Search removable media floppy CD ROM v Include this location in the search C EasIR 4 EasIR 4_USBdrive x O Dont search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver y
9. infrared image can be saved into 2GB SD card or the built in flash memory in standard JPG format e SD card can accommodate 2000 images and the built in flash memory can store 200 images Image Playback e Images saved into SD card or the built in flash memory can be replayed on the camera e Temperature measurement can be done on replayed images e Images saved in SD card and the built in flash memory can be downloaded to PC for further analysis and report generation with software Guide IrAnalyser Parts Described User Manual LCD Display Charging Indicator Function Softkeys Microphone Battery Cover Speaker EASIR 4 only Visual Camera EASIR 2 4 only Laser EASIR 2 4 only N oO a J wy N IR Lens o Trigger Button 11 USB Interface Video Interface EASIR 2 4 only AC Adapter Charging Input Terminal SD Card Slot Gai de User Manual EASIR 0 Charging Instruction How to use the batteries M Zo Insert the batteries the indicator will not flicker at once Press button to make the red indicator flicker after 2 seconds the indicator will alternatively flickers as green and red and stop when entering the self check interface If the camera is powered on when battery is low the red indicator will flicker quickly and power off automatically When using the camera if the batteries consume to th
10. it the spot analysis and return the real time IR mode Manual calibration F On the non menu mode keep pressing T button and then press button to run shutter calibration Image frozen and save On the non menu mode press T to freeze the image the following info will be displayed on the screen se x _ Gucde User Manual Press T again to exit frozen mode and return to the real time IR mode or F Press to save the image and return to live thermal image Main menu operation M On the non menu mode press to bring up Main menu the following info will be displayed on the screen Press T in the main menu to return real time IR mode On the main menu mode press i 3 3 to enter sub menu of parameter setting On the sub menu mode press to confirm selecting the highlighted option and enter the next sub menu press T to exit main menu operation and return to real time IR mode k2 On the main menu mode press to enter file operation sub menu i P On this sub menu mode press amp to enter next sub menu press T to exit main menu operation and return real time IR mode PI On the main menu mode press 4 to enter system setting sub menu Guide User Manual Default Language Tunit TimeDate AlarmTemp j P On the sub menu mode press to confirm selecting the highlighted option and enter the next
11. nal 25G IEC 68 2 29 Vibration Operational 2G IEC 68 2 6 Interfaces USB 2 0 Real time image and measurement transfer to PC Physical Characteristics Weight 0 73KG including battery Size 111mmx124mmx240mm Colors Yellow amp blue interlaced or red amp dark interlaced alternative System Features Unique Features e Rugged housing and rubber protection offers high effective operation even in harsh environment e Big 3 6 LCD plus three button button system make for a friendly navigation with the push of a thumb e Unique ergonomically handle presents the comfortable feeling e Auto gate which works as both shutter and intelligent lens cap prevents all disturbing heat radiation caused by optics and electronics inside delivers crisp and uniform images and protects the precise lens e Ultra large capacity SD memory card and built in flash memory offer easy in field storage e High speed USB2 0 interface enables real time data transfer and camera control e Robust on board analysis enhances operators efficiency amp productivity e Low cost enables the ownership of everyone Imaging Performance e Motorized focusing of IR lens Temperature Measurement e Auto calibration ensures high accuracy e Auto hot spot tracing and center cursor temperature measurement pinpoint the problem Image Storage Guai de User Manual e Live images can be frozen to be static images e Frozen images comprising radiometric data
12. ng from Wuhan Guide Infrared Co Ltd Table of the Contents Table ofthe Contents iniciada ra E ea arde 1 IO TUCU tai 1 Precautlorns uu iacit etn Dd 1 E aa aaa aaa anaa a a aa aaa aranan ann aaaea 1 Calibration and Repair Philosophy o decedat is 2 Technical SUPPOM ease Gee dilli dr D R a karek k 2 Feedbackto ERE EE EP EE EIER E ERI RR ERES 2 System OVE VIEW P L daka 2 System Configuration E E Eke kk kk kk ek kek OR E ROM UR KAKA KAR Ak KA KAR kk rk A 2 Technical Special tallar KAR KAR KAK KAK A AA 3 SICHERER 4 Parts DescriDed s eoe a ete ki ani xek yasi zal waran Ere ter Ee aaa 5 EASIR 0 Charging Instruction id ceo eoruni Dus Du equi e tuu buc tu wane Ed aep Du cuu RD Saat 7 Buttons Introduction ieu aid K RA KAWA K RA KARA K RA AR W KA WALA H KA 7 A SIRR YO DD e e N e E 10 Guide User Manual Introduction This publication provides the necessary information required to safely operate the GUIDE EASIR 0 Thermal Camera It is important to fully check all equipment with which you have been supplied The equipment should be used maintained and serviced by suitably trained personnel capable of carefully following the procedures and guidelines given in this User Manual All User Manuals and leaflets should be read thoroughly before proceeding with operation of the equipment It is also advisable that all User Ma
13. nuals and Instruction Leaflets supplied are kept readily available for reference when the equipment is in general use Precautions The following precautions must be adhered to at all times and must be considered in addition to any advised precautions issued at the relevant worksite or work area e Keep the GUIDE EASIR 0 Thermal Camera steady during operation e Do not use the GUIDE EASIR 0 Thermal Camera in temperature exceeding its working and storage temperature ranges Do not direct the GUIDE EASIR 0 Thermal Camera at very high intensity radiation sources such as the sun carbon dioxide lasers or arc welders etc e Do not expose the GUIDE EASIR 0 Thermal Camera to dust and moisture When operating the unit near water ensure that the unit is adequately guarded against splashes e When the GUIDE EASIR 0 Thermal Camera is not in use or is to be transported ensure that the unit and its accessories are stored in the protective carry case e Donotre switch on the camera until 15 seconds later after switching it off Do not throw knock or vibrate intensely the camera and its components in order to keep them from damage Do not attempt to open the camera body as this action will void the warranty e Keep the SD memory card for the exclusive use of the camera WEST Tal lala elo To ensure that the GUIDE EASIR 0 Thermal Camera is kept in good working condition and remains fully operational the following guidelines should be a
14. ocedures to go to Device Manager is as follows Clicking My Computer gt Clicking the right mouse and choosing Property gt Choosing menu Hardware in the System Property dialog box Choosing option Device Manager under the menu Hardware 1 Device Manager QuE File Action View Help m 62a 5 IDE ATA ATAPI controllers Sy IEEE 1394 Bus host controllers C Keyboards 15 Mice and other pointing devices ll Modems 9 Monitors Ml Network adapters PCMCIA adapters Processors Sound video and game controllers System devices Universal Serial Bus controllers GUIDE EasIR 4 Intel R 8280 1DB DBM USB Universal Host Controller 24C2 Intel R 8280 1D8 DBM USS Universal Host Controller 24C4 Intel R 8280 1DB DBM USB Universal Host Controller 24C7 Intel R 8280 1D8 DBM US82 Enhanced Host Controller 24CD USS Root Hub USB Root Hub USB Root Hub USB Root Hub 4 4 ot 15
15. ou choose will be the best match for your hardware Installation starts When getting to the step as shown below choose Continue anyway to proceed further r Found New Hardware Wizard Please wait while the wizard installs the software E e GUIDE EasIR 4 The software you are installing for this hardware GUIDE EasIR 4 with Windows XP y Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and ce contact the hardware vendor for software that has passed Windows Logo testing has not passed Windows Logo testing to verify its compatibility Tell me why this testing is important STOP instalaton Installation continues and finishes quickly Click button Finish 14 G aide User Manual Tr Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for GUIDE EasIR 4 The hardware you installed will not work until you restart your computer Click Finish to close the wizard Go to Device Manager to check and confirm whether the driver has been successfully installed lf there is GUIDE EASIR 0 listed under Universal Serial Bus Controller it indicates the driver has been properly installed and you can transfer data from the camera to PC now The pr
16. the softkey labeled Tunit Le P Press for Celsius or for Fahrenheit Doing spot analysis EASIR 0 supports single spot measurement The location of center spot can be adjusted in live image DNE C Press 4 button and then button to bring location adjustment mode of center spot M KANN C The default adjustment mode is Left Right mode press and A J can move the center spot to left and Aa right under this mode press P button to switch into Up Down mode then press and can move the center spot to up and down under this mode Press P button can switch between the above two modes freely Press trigger button can save and exit the location adjustment mode of center spot How to get accurate temperature There are a lot of factors affecting temperature accuracy Here is a brief introduction to some typical parameters emissivity background temperature distance humidity and etc Y Note To get accurate temperature you shall hold the camera stably and focus the camera well Emissivity All objects radiate infrared energy The amount of energy radiated is based on two primary factors the surface temperature of the object and the emissivity of object s surface The default emissivity is 0 98 which is applicable to most surfaces For some special materials or surfaces please refer to the emissivity table to find a right emissivity value Yo
17. u can change emissivity between 0 01 and 1 00 in menu Para and Emissivity Tamb To display and adjust the real time comparative scene temperature of target The default setting of this parameter is automatic adjusted by the internal temperature sensor If needed this setting can be adjusted manually according to real temperature of some special scenes like sky or snow of measured target B button and 3 button to bring the submenu of parameter setting then choose Tamb and select e Po Set option to set the value manually by press button and button The new measurement will be based on the saved tamb value until re enter the Tamb option and exit which will activate the default automatic mode 12 Transferring Data from the Camera to PC Guide User Manual Distance To set the proper distance from target the distance range is from 0 1 meter to 50 meters Relative Humidity To set relative humidity percentage value between O and 100 according to the practical environment Before transferring data from the EasIR 0 camera to PC ensure that the PC offers USB2 0 interface and the USB driver for the camera has been successfully installed in the PC If SD card is inserted in EASIR 0 the PC will identify the EASIR 0 as a removable hard disk you can copy the saved data to PC or delete them from the card or even format the SD card and etc But you cannot operate on it in t