programming manual integrated panels ksi1000016

image

Contents

1. 3 A Vo oso Lisa fre Expo dal ipiri dali Pr rear CH ker ky Poa han tia E CUSTOMER NEW CUSTOMER The New Customer button opens the programming window for a new customer that will be added to the list of customers on the software Pr REFRESH LIST The Refresh list button is used to refresh the customers list EXPORT DATA TO FILE The Export data to file button saves the customer s programming on a single file This button is enabled only in the customer s management window IMPORT DATA FROM FILE The Import data from file button allows to import a customer s programming from a file previously created with the Export data to file button Use this procedure to move the programming data from one PC to another or create a new configuration starting from a previously prepared programming SAVE The Save button allows to save the customer s settings on the database software FIRMWARE UPDATE The Firmware Upgrade button opens the window from which you can upgrade the firmware of the connected devices or KS BUS peripherals which can be put up to date without the need of changing the system wirings or configuration First you have to select whether you want to update a device connected to the PC and listed in the Serial ports and devices connected list or if you want to prepare your file to be saved on a USB flash drive in order to connect it to the device you want to update By pressing th
2. Modify PIN appears only if the programming menu is entered by a code and not by a RFID key lares programming manual 58 59 ergo version It shows the serial number and the firmware version of ergo keypad INSTALLER MENU STRINGS Partitions Scroll of partitions e Description e Automatic memories restore e Pre alarm time sec e Exit time sec e Notice time min e Patrol time min Arming Scroll of arming e Description e display the actions associated with each partition for that arming mode no action 0 disarming T arming TT immediate arming c toggle e Scroll of partitions and possibility to associate the action to be performed when that arming mode is relied Possible actions for each partition are e No action e Arming e Immediate arming e Disarming e Toggle lares programming manual Zones Zones Scroll of zones Scroll the Zones e Kind of Zone e Wired e Wireless PIR e Wireless CM e Wireless AUX e Wireless SMOKE e Description e Mode e Not used e Standard e Inertial e Roller blind e Analogic it appears only if the zone has been programmed analogic by basis Using the keypad is not possible to program an analogic zone e Balance e Normally open e Normally closed e Balanced e Double balance e Triple balance e Tamper balance e Custom if appears only if the thresholds have been customized through basis When programming from keypad is not possible
3. Correct disposal of this product guarantees if undergoes the necessary treatment recovery and recycling This prevents any potential negative effects on both the environment and public health which may arise through the inappropriate handling of waste Please contact your local authority for further details Y RoHS 2002 95 EC lares programming manual we care Ksenia security innovation www kseniasecurity com
4. KEYPAD LANGUAGES On this page system language can be choosen You can program up to 10 languages on the Panel available languages on lares taken from the list of available languages available languages on basis DATE AND TIME OPTIONS DATE MODEL Select the date model you want among those proposed DD MM YY day month year example 31 01 13 MM DD YY month day year example 01 31 13 YY MM DD year month day example 13 01 31 HOUR MODEL Select the hour mode you want between 12h and 24h EVENTS LOG On this page you can read the event log of the Panel Press the E Load button in the main menu to read the event log You can select events and copy them Ctrl C for example to store them on a text document Events are stored on non volatile memory Flash with 100 000 write cycles and a minimum of 10 years of data storage REALTIME EVENTS Activating this button the software periodically checks the Panel register downloading the new events as they occur REALTIME In the Realtime pages you can check the System status If provides the display of the Zones status Realtime zone the outputs status partition status Realtime partition the status of devices connected on the BUS Realtime devices the wireless devices status wireless Realtime and Panel and failures status Panel realtime lares programming manual ergo LCD KEYPAD PROGRAMMING MENU To enter the programming menu by ergo keypad enter th
5. Low battery Missing Ethernet Missing PSTN line GSM trouble Fuse protection Power supply faults Low power supply voltage Battery faults Communication faults System reset PROGRAMMING OUTPUTS SECTION Select the output associated with imago siren or relay output if you are using third parts sirens Select the output associated with imago siren or relay output if you are using third parts sirens You must also select When system armed in Activate output section output activation is required only for the GRADE 2 Is not allowed to activate no acoustic signaling device PROGRAMMING DESTINATIONS SECTION Select at least one destination present on phonebook Select at least one destination present on phonebook Select at least one destination present on phonebook If you programmed Zone alarm events you do not need to program the partition alarm and vice versa Similarly should be programmed Zone tamper and Partition tamper events ARMING AND DISARMING OPERATIONS ALLOWED All options that allow to arm and disarm the System without the use of an adequate level of access do not conform In particular you cannot bind arming mode to zones programmed as Command or keys on the keypad that has enabled the No PIN option ALARMS TRANSMISSION GRADE 3 Events should be transmitted to the alarm receiving center exclusively through GPRS network via gemino Communicator ATS4 or Ethernet in case of IP Panel with SIA DC 0
6. Partition events o partitions Number of Keys on keypad keypads Number of Readers readers Number of timers of Scheduler Scheduler NOTE OCCURS WHEN Analogic input voltage falls within level 1 Analogic input voltage falls within level 2 Analogic input voltage falls within level 3 Analogic input voltage falls within level 4 Analogic input voltage falls within level 5 The zone alarm occurs one of zones goes in alarm The zone alarm occurs one of zones goes in tamper The negligence timer expires The partition arming is not successful Macro 0 activated on keypad or code entered macro O Macro 1 activated on keypad or code entered macro Macro 2 activated on keypad or code entered macro 2 Macro 3 activated on keypad or code entered macro 3 Macro 4 activated on keypad or code entered macro 4 Macro 5 activated on keypad or code entered macro 5 Macro 6 activated on keypad or code entered macro 6 Macro 7 activated on keypad or code entered macro 7 Macro 8 activated on keypad or code entered macro 8 Macro 9 activated on keypad or code entered macro 9 Activated scenario associated with the Green LED on the reader Activated scenario associated with the Red LED on the reader Activated scenario associated with the White LED on the reader Activated scenario associated with the Blue LED on the reader Activated scenario associated with the Yellow LED
7. on total arming Long pression 3 seconds on i 600 UX key on Remote total arming key control Long pression on disarming key on Long ie 3 e OM 600 UX disarming key Remote control Long pression on partial arming Long pression 3 seconds on i 600 UX key on Remote partial arming key control Code Number of A valid code is entered on Code i 422 JP 00 recognized codes keypad number id Nie A valid Tag i hed t T b valid Tag is approached to ag number Tags recognized Number of Tags the keypad or to a reader 422 JP 00 200 lares Panel number of imago sirens number Battery fault of wireless Failure of battery dynamic test 311 YT 00 000 detectors number of opis power supply stations Periodic test 1 Periodic event 602 RP 00 000 Other events Controlled shutdown of the System shutdown 1 system when it miss the power 600 JR supply and the battery is discharged The Panel was restarted System reset because it is removed and 600 yw then restored the power supply or due a system failure For three consecutive times Wrong code you have typed a wrong PIN 421 DD 00 000 code on the same keypad Communication Phonebook Communication phonebook Caller contacts The caller number Is 402 DU 00 Phonebook recognized recognized CLIP function number odia by imago X is minor than the 159 ZA 00 g D lower threshold CE imago X Temperature eeriules Number of The temperature measured within threshold p imago by imago X is between the 159 ZA 00
8. AFTER DISARM Selecting this option manually excluded Zones are automatically re included at the moment of disarming FIA In order to maintain conformity with norms listed on page 73 this option must be enabled LOCK KEYPAD ON WRONG PIN Selecting this option enables every keypad to lock after 3 wrong codes FIG In order to maintain conformity with norms listed on page 73 this option must be enabled USE ZONE 1 FOR SERVICE SYSTEM TEST By selecting this option the zone 1 behaves as a service entrance putting the Panel in maintenance when it is violated lares programming manual CLEAR TAMPER MEMORY WITH USER CODE By selecting this option you can use user code to erase the tamper memories from the Reset Alarms menu on the ergo keypad FIA In order to maintain conformity with norms listed on page 73 this option must be disabled LIMIT LOG ENTRY NUMBER PER EVENT Enabling this option keeps the memory in the register a maximum of 8 occurrences for each specific event occurred within a arming disarming cycle or until the next maintenance of the system If this option is NOT selected the Panel will display the event log for each occurrence FIA In order to maintain conformity with norms listed on page 73 this option must be enabled DENY SYSTEM ARM ON FAULT CONDITION By default the Panel allows any kind of arming in the presence of a fault and or tamper Selecting this option the Panel will not arms the partitions in case of faults FI
9. GENERIC TIMERS Every event in the system can activate or deativate up to 2 generic timers Both the start and the expiration of these generic timers are system events as well so they can be used to generate cyclic events For each timer can be programmed a label and a duration expressed in seconds SCENARIOS The scenarios page is the heart of the System Each event in the system can be used to generate actions as output set reset toggle generic timers start stop arming modes calls Hereafter some examples are shown EXAMPLE 1 PROGRAMMING ARMING DISARMING FROM KEYPAD Let s assume that you have previously defined one or more keypads and activated some functions that can be associated to keys Let s further say you have defined in the arming page an arming mode called Total Disarming 1 and one called Total Night Arming If you want to associate with the O Key on the keypad 1 a system disarming will be sufficient to assign the event 0 Key on Keypad 1 in the Arming mode column the Total Disarming 1 entry earlier defined In the same way we can associate with the 1 key in the same Keypad Total Night Arming mode we could assign to the Disarm partition 1 event the reset of an output EXAMPLE 2 RELAY AND COMMUNICATOR ACTIVATION TO THE OCCURRENCE OF AN ALARM When a partition alarm occurs simply assign an output e g relay in the output column of the Partition Alarm event if we also want to start a phone call or an
10. Let s see its programmable parameters LABEL The label is the description that you want to give to the Supervised Power Supply Station and will be used as a label in other programming pages shown in the events log and used as a string for SMS or e mail alerts Each device on the BUS hence also the opis Supervised Power Supply Station is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS lares 2 7 programming manual 28 duo BUS WIRELESS TRANSCEIVER duo BUS wireless transceivers can be added to the system The number of programmable transceivers depends on Panel model To add a wireless transceiver drag the corresponding icon from the palette to the page or select it by pressing the O Add button in the main menu Let s see its programmable parameters LABEL The label is the description that you want to give to the Wireless Transceiver and will be used as a label in other programming pages shown in the events log and used as a string for SMS or e mail alerts Each device on the BUS hence also the duo BUS Wireless Transceiver is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is
11. are Normally Open Normally Closed Balanced 10K Double balance Parallel 2 x 10K Double balance series 2 x 10K Triple balance 3 x 10K Tamper single balance 10K Fault single balance 10K and Custom Selecting the last option you can customize the thresholds and the banas Please refer to the panel manual for details on wiring and thresholds In the case of analogic zones you cannot select the type of balance but there are 4 programmable thresholds that determine 5 levels Depending on the value of the input voltage the event corresponding to the level to which it belongs is generated FIA In order to maintain compliance with the norms listed on page 73 NC and NO options must be excluded PARTITIONS MASK Assign the zone at least at one partition the association makes it possible to arm disarm a zone when the associated partition is armed disarmed assign delay times to a zone If a zone belongs to multiple partitions it raises the alarm only if all partitions to which it belongs are armed BYPASS MODE BYPASSABLE When this option is selected the user will be able to bypass the zone A bypassed zone does not report alarms Tampers and faults masks will continue to be reported UNBYPASSABLE If this option is selected the user will not be able to bypass the zone AUTO BYPASSABLE If this option is selected the zone is automatically bypasses if it is violated when arming Th
12. as when an alarm event raises the siren starts sounding and flashing ONLY LAMP ADDITIONAL LEDS Outputs can also be assigned to the blinker only Only Lamp and auxiliary signalling LEDs Additional Leds These can be programmed for example to report the arming status MAXIMUM ALARM TIME Maximum time of activation of acoustic signal and siren light for cutting wires DUAL TONE BUZZER If this option is selected the acoustic signal is performed by means of a sound with two separate frequencies if unchecked it instead sweeps the frequency lares programming manual BUS CONTROL If this option is selected the siren will emit an acoustic signal if there is no communication with the Panel for longer than 10 sec TEMPERATURE THRESHOLD CHECK The siren integrates a temperature sensor which allows to measure the outside temperature By enabling this option you can raise an event if the measured temperature is lower than the Low temperature threshold an event if the temperature is above the High temperature threshold and an event if the temperature is between the two thresholds DISABLE TEMPERATURE SENSOR If this option is selected the siren does not send the temperature and is not used for displaying outdoor temperature on keypad this is useful if there are two sirens and one of these is installed in a sunny position distorting the outdoor temperature measurement E radius INDOOR SIREN radius indoor sirens can be
13. customer and insert the appropriate data in relative window e figure 4 Once created the customer record is inserted in the aoe list and you can optionally edit the data by pressing the right i me slatted mouse button on the name que 1 Double clicking opens the Manage account window in this En habra window you can associate to the client the devices that will be installed in the system figure 5 Once you have selected your device simply press the Next button and then assign a name to the device itself which will identify and upload data conveniently in subsequent links By pressing the button Finish it creates the device with its programming menu figure 6 To open a programming page simply double click on the entry of the menu that you want to open partitions arming modes etc The Navigator will be automatically activated to allow you to move on several pages of programming without having to return to the manage account E Pee ian TELET lares series have a very similar programming between the various models here is expressly indicated when some features are referable only to certain models The software allows you to create the zones or outputs determine where they phisically are located e g mainboard zones keypad zones and then program the Scenarios Scenarios are a set of actions that the panel performs when a particular event occurs as a zone alarm or partition Fo
14. following paragraphs lares programming manual 17 18 PERIPHERALS On this page you can define system hardware configuration add peripherals their attributes and assign the input output terminals functionalities A physical terminal can be assigned to a zone earlier defined or to an OC output or left unused MOTHERBOARD The first part of the programming tree is the Motherboard terminals configuration Let s see its programmable parameters ZONES 11 16 TERMINALS Inputs only Program logic zones to be assigned to the terminals named 1 i6 on the motherboard M1 M4 TERMINALS Inputs Outputs Program logic zones or outputsto be assigned to the terminals named M1 M4 on the motherboard VIRTUAL KEYPAD The virtual keyboard is used during remote operations e g via telephone or web server MACRO FUNCTIONS DESCRIPTION Enter a description that you want to give to the scenario associated with the key which will be used as a label in the other pages shown in the events log used as the SMS Dialer strings and used in the generation of voice messages ARM REQUEST You can bind to the desired arming mode Select Enabled if you want to activate the corresponding button The rest of operations ouputs activations timers etc must be programmed in the Scenarios page see following paragraphs PARTITION MASK The Partition Mask can also be programmed for the Virtual Keypad it defines the partitions on
15. mesa E on imago X lower and the upper threshold dd Temperature The temperature measured i over threshold by imago X is greater than the 158 ZH 00 e nt On imago X Upper threshold eee 69 lares programming manual KIND OF EVENT Temperature under minimun threshold on radius X Temperature within threshold on radius X Temperature over threshold On radius x CATEGORY Temperatures RECURRENCE Number of radius Number of radius Number of radius OCCURS WHEN The temperature measured by radius X is minor than the lower threshold The temperature measured by radius X is between the lower and the upper threshold The temperature measured by radius X is greater than the Upper threshold lares programming manual Contact ID EVENT CODE 159 159 158 SIA EVENT CODE LA LA ZH GG PARTITION 00 00 00 CCC ADDRESS radius siren number radius siren number radius siren number 70 PROGRAMMING SUMMARY This paragraph summarizes programming options that ensure the proper functioning of Panel based on the parameters defined by the norms listed on page 73 If these programming data are changed the Panel shall NOT be compliant with these norms PROGRAMMING ALARM TAMPER AND FAULTS EVENTS EVENT Zone alarm Partition alarm Zone tamper Partition tamper Panel tamper Controlled output tamper Peripheral tamper Missing Peripheral Masking Zone faults Missing net
16. not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS ENROLL WIRELESS DEVICES Wireless devices enrolling occurs in three steps Pressing the Enroll Wireless Devices button in Peripherals section it will start a Wizard designed to facilitate this operation 1 ENROLLING PROGRAMMING OF duo TRANSCEIVERS BUS 1 If you do not have the serial number of the duo transceivers BUS press assign serial in peripherals realtime section 2 Proceed in the device programming as specified in the appropriate sections 2 ENROLLING PROGRAMMING OF duo REPEATERS 1 If you do not have the serial of duo repeaters put on sabotage the selected device for a few seconds and then put it back in service Do this for all repeaters 2 Proceed in the device programming as specified in the appropriate sections 3 ENROLLING PROGRAMMING OF WIRELESS DEVICES 1 Enrolling of wireless devices e The Contacts and the Detectors are enrolled on the tamper restore e The Remote Controls are enrolled on the long press of the info button e Smoke sensors are captured as soon as powered them up or pressing the button on the radio module 2 Proceed in the device programming as specified in the appropriate sections lares programming manual s WIRELESS PERIPHERALS duo REPEATER One or two
17. of the alarm zones the option Analogic must not be selected e Regarding the balancing of alarm zones Normally Closed and Normally Open options must not be selected e Enabling the Self exclusion option is allowed only when using the scheduler and enable the Automatic Reinclusion option e The Pulse lenght option must be greater than 400 ms e The Include zones after disarm option must be enabled e On the options page faults must be all enabled e On the options page the Lock Keypad on wrong PIN option must be enabled e On the options page Clear tamper memory with user code option must be disabled e On the options page the Limit log entry number per event option must be enabled e On the options page the Deny system arm on fault condition option must be enabled e On the options page the Detect bypassed zone tamper option must be enabled e On the options page the Enable faults memory option must be enabled e On the options page the EN 50131 arming check option must be enabled e The BUS Control option on imago siren must be enabled e On the events page must be enabled the Clear call queue option for all the events of partition disarming lares 72 programming manual 73 CERTIFICATIONS T 014 1th Edition 2003 A1 2002 A2 2003 A3 2005 EN50131 3 EN50131 6 EN50136 1 1 CERTIFYING BODY Dl IMQ Sistemi di Sicurezza GRADE 3 CLASS Il Installation of these systems mu
18. on exit path when it is violated and then restored during the exit delay time it automatically resets it Referring to Pic 7 zones marked with 0 1 and 2 must be marked as exit delay and the 0 one marked as last exit KS lares programming manual NUMBER OF PULSES Number of pulses required before the zone alarm is raised this is standard pulses in case of Standard or Command zone fast pulses in case of Shutter or Inertial zone In the case of wireless unum zone this value can take only values 1 2 or 3 4 and will act on the detection sensitivity of the sensor PULSE LENGTH Single alarm pulse duration This value determines the amount of time that the zone must be violated before a valid pulse is generated and valid for all processing modes For example if we program a zone as Shutter the alarm will be generated if there are a number of fast pulses programmed movement of the shutter or if the contact remains open for the programmed time in this window security wire cutting In the case of programmed zone as Shutter by setting this to O will make only quick analysis of impulses and not generate alarm if the contact remains open ALARM WINDOW Window within which the number of programmed impulses must occur In the case of wireless unum zone this attribute indicates the minimum time interval between the detection of two consecutive alarms Increasing this interval of time it is possible to incre
19. on the reader Expiry of timer of Scheduler lares programming manual Contact ID EVENT CODE 130 137 404 120 120 120 120 120 120 120 120 120 120 600 600 600 600 600 630 SIA EVENT CODE BA TA UX PA PA PA PA PA PA PA PA PA PA UX UX UX UX UX DU For Occurrence means the number of times the event occurs in the table For example the alarm zone occurs once for each zone GG CCC PARTITION ADDRESS Associated partition 00 if the zone belongs to more than one partition Partition number Partition number Partition number 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Numero zona Numero zona Numero zona Numero zona Numero zona 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 68 Contact SIA KIND OF ID GG CCC CATEGORY RECURRENCE OCCURS WHEN EVENT EVENT EVENT CODE PARTITION ADDRESS CODE Total arming key on Remote Short pression on total arming 600 UX key control Disarming key on Short pression on disarming 600 UX Remote control key Partial arming s key on Remote Short pression on partial 600 UX arming key control Long pression on info key on Long pression 3 seconds on 120 UX Number info key Remote control Remote controls of Remote Lonf pression controls
20. the lithium battery on the siren to allow operation as emergency light lares 25 programming manual 26 LED ALWAYS ON If this option is selected activating the associated output in Only Lamp section the LED is lit not blinking TEMPERATURE THRESHOLD CHECK The siren integrates a temperature sensor which allows to measure the outside temperature By enabling this option you can raise an event if the measured temperature is lower than the Low temperature threshold an event if the temperature is above the High temperature threshold and an event if the temperature is between the two thresholds DISABLE TEMPERATURE SENSOR If this option is selected the siren does not send the temperature and is not used for displaying outdoor temperature on keypad this is useful if there are two sirens and one of these is installed in a sunny position distorting the outdoor temperature measurement PARTITION MASK Programs the partitions associated with radius siren When the system is asking to activate the alarm signalling the siren will activate the acoustic signal only if all partitions that are associated with the siren are armed This lets not to have the siren sound if people are in the house If you want the siren to sound independently by the arming mode do not associate any partition to the siren Y volo PROXIMITY READER volo proximity readers can be added to the system The number of programmable readers depends on Pane
21. the mode is enabled the partition is armed but input and output delays are valid for the delayed zones of partition only DISARM When the mode is enabled the partition is disarmed TOGGLE When at least one partition is armed it disarms all partitions When all partitions are disarmed inserts them alll lares programming manual ZONES On this page you can program the parameters relating to the Zones To program a zone press on the O Add button or drag the corresponding icon from the Palette programming page Let s see in detail each programmable field ZONE TYPE Identifies the type of zone you want to use Can be configured in the following ways WIRED Wired zone WIRELESS UNUM Zone assigned to the unum wls indoor motion detector POLI NANUS MAGNETIC CONTACT Zone assigned to the poli or nanus wireless magnetic contact AUXILIARY ZONE ON POLI Auxiliary zone assigned to the poli wireless magnetic contact WIRELESS NEBULA Zone assigned to the nebula wireless smoke detector PROCESSING MODE Select the zone type which determines the type of signal analysis Available in standard roller blind inertial for glass break sensors command if you do not want to use the area to generate alarms but only to enable scenarios or analog to connect sensors with analog output 0 10V NOTE 1 To test the operation of the shutter type and inertial sensors taking into consideration the rapidity of the pulses generated
22. those proposed figure 15 OTRAS das you 86 rete a hagname Pat fonts Lo your homa Ge office F addres ered an a e WAL For gu cor We provide dn uo mechingem whieh makes the hostname work wth your dyed P ddr 6 Create the host figure 16 1 Hostname Enter in this field the identifying name of your network your panel or its location bg Aremm Sy rw m we ont baa ld 2 Dominio Select the second part of the en eG it EA E e sal AT 24 EAT CRA PO PAT ACNE TIE A UTA ERAN address among those proposed So LALI bami i i a Ae wer eee et ef eee eee oe es 3 IP Address Enter in this field the IP address aos hies Se ee pl assigned to the network that contains the iii Pr eer Sot e a panel from your ISP _ ee er y 4 Add To Cart Press the button to continue NOTES A ma a e a EE 1 The address through which the user can access to the network that contains the panel and then to the panel will be http hostname domain l Teg Aare a ara aa aa aala 2 For security reasons if one http port other than the one set by default port 80 has been assigned to the panel you must specify this value in 4 the address preceded by the character colon EXAMPLE hitp hostname domain 1234 in which 1234 is the port value 7 Confirm the host creation figure 17 select the desired payment method and confirm the service activation figure 18 NOTE The figure shows the displayed screen from the server if you wa
23. you have selected Enable external antenna Select this option if you don t want the device to use the internal antenna in case of GSM signal issues for example if you put gemino inside a metal box VOCAL MENU Enable activation of voice guided menu in case the number of the SIM is called Through this tool the user can control the panel after entering a valid user code JAM DETECTION Select this option if you want gemino signals any noise on RF carrier of GSM that prevent communication Network parameters credit control and expiration can be programmed for each SIM CARD INGOING GPRS DATA PORT This parameter is required only if gemino is programmed to remotely manage the system via GPRS For more information please refer to the REMOTE ASSISTANCE paragraph lares 1 9 programming manual 20 OUTGOING GPRS DATA PORT This parameter is required only if gemino is programmed to remotely manage the system via GPRS For more information please refer to the REMOTE ASSISTANCE paragraph DYNAMIC DNS SETTINGS In this section parameters for configuring a server that handles dynamic DNS are programmable For more information refer to the paragraph DYNAMIC DNS SIM OPTIONS By selecting one of the available SIM you can view the options regarding the SIM itself CREDIT CHECK CHECK INTERVAL Is the maximum time in days between two credit checks The device however checks the credit after every phone call and ev
24. 23 Meis lo e e o A A a PAP 23 mago DNIO en aar a a E are cnr a E E ae Senet A 24 e lo Ole SING E EA E E O E E A AEE tena A E O O EA ITE EE AEA ata E EAN OE 25 MO er IAI le lo e a a A a NN 26 Avda US SO MORENO ME o cree ae Sa O o ao 27 Op UPEN eA POW SUPPIVS ONON A a eagle NE E A ac ma E Mahle Nor Nem ns Meas nu RA 27 SS a E E 28 sala Wal S DEV Co AA a a a a a a E a a A ea ah 28 WIRELESS PERNIPHEPAES TAn ae a A o E teat near a 29 quo RE Dedicada dt a oot A E tbn 27 nl celola IE Che ay to ei A E Oe es Re Near te ete seth E eon eae 29 CHUM WAS AIC Ol so Ci Oly zinnen Gee oleae Aas Aah A MAE Aor NS ERE TL 30 MODULA SIMO Ke ICTS GLO ae ir ee iim ea aU ra nie Od AL O orn o tetanic ge om pana 30 OPEREN om Oe ali ga eoar e rome rt cane errr ee 3 PHONEBOOK rento teria Reese Matveev alone a ane Shea Baa No hous ei ee Gay eo errs hem ama 32 USER ROUR e a A ei ARA E reco 34 CODEN tonto it a a Pi omar emirate a a a A E EAN 35 VAS A AA A E E E A A E O 36 VOICE MES SACE a nena o ato vt aa leia tee VA 37 GRAPHIC IMAR ee a E E E E A E E E E AE niendo 38 A E E A E A E E EA fen nae rt dante a E toate eee ae O 40 O A E O 42 PROGRAMMING OFACCOUNTDATA CONEA RES EAN Else ie art oe a a e al de dai 45 IFREMER S a At nato de io 46 CTEM IN Ste no ato e td ra rollito 47 SCHEDULER A O en erste aN lease Aaa A 50 SS NDA ear nie eee ga a ae fra oe hoe lu a Meena a he nays Sera A pa eee ore 50 REMOS IS TAN SE tn DN tne at anon a A eS 53 Ke Eee AN Cs St asset ca nea t
25. 9 communications protocol On the contacts page can be programmed the IP receiver to be selected as a destination To enable events transmission on IP you must turn on the Enable events on IP option You also need to enable a supervision by selecting Enable supervision or programming the receiver as the destination on Periodic Test event The Periodic Test period to be set on the options page must be less than 300 minutes 71 lares programming manual ALARMS TRANSMISSION GRADE 2 The use of pontis ATS2 and text to speech communication is permitted You must enable a supervision programming a destination to the Periodic Test event The Periodic Test period to be set on the options page must be less than 1500 minutes In any case the Confirm call result should be always enabled OTHER CONSTRAINTS ON PROGRAMMING e The maximum programmable input time on partition page should not exceed 45 seconds e Incase of using scheduler the notice timeprogrammable on the partitions page must be greater than 0 Must also select Notice option in Acoustic feedback for each ergo keypad programmed into System e For each ergo keypad programmed into your system must be enabled Input time and Exit time options of Acoustic feedback section Between operations at rest must be selected the Notices with PIN while Open Zones and Partition status options should NEVER be enabled e Regarding the processing mode
26. A In order to maintain conformity with norms listed on page 73 this option must be enabled DETECT BYPASSED ZONE TAMPER If this option is not selected disables both the alarm signals and sabotage of all excluded zones By selecting this option the zone exclusion only excludes alarms A In order to maintain conformity with norms listed on page 73 this option must be enabled ENABLE FAULTS MEMORY By selecting this option the Panel displays the keypad failure recovery through the words Fault Memory This memory will be erased only after an inspection of the section Faults Status by a level 2 user FIA In order to maintain conformity with norms listed on page 73 this option must be enabled EN 50131 ARMING CHECK By selecting this option the Panel aborts the arming if that generates an alarm and raises the Arming Fault event FIA In order to maintain conformity with norms listed on page 73 this option must be enabled lares programming manual 48 49 PERIODIC EVENT The Panel can be programmed to periodically send an error report for example to check that it is working properly DATE AND TIME FIRST PERIODIC TEST In this section you can set the date and time of the first send a periodic message in order to check it works properly periodic event PERIOD Period in munutes of the periodic event If this value is O periodic event will not be generated FIA In order to maintain conformity with the norms listed on page 73 the
27. NVIF standard are open The following table summarizes the requirements for a proper recognition of the ONVIF devices NETWORK The PC on which basis is running and the ONVIF camera must be connected in the same subnet They must be physically connected to the same router and they CONNECTIONS must have the same subnet mask Subnet Mask COMMUNICATION In communication time basis and ONVIF device will use UDP port 3702 standard PROTOCOL Web Services and port 80 over HTTP Both ports must be open and not blocked by firewall lares programming manual DATA ACCESS MODALITY Accessing data of ONVIF cameras depends on device manufacturer None of the ONVIF commands that are implemented to achieve the standard integration in basis need authentication They can be used without the use of camera username and password Any authentication request is entrusted to the device when accessing video streaming It is possible however that some producers force the ONVIF to require authentication for commands that do not require specifically For this reason the basis programming interface provides the possibility of providing authentication data directly during scanning devices Hence there are two possible scenarios 1 Ascan is made for ONVIF devices that are on the network without provide authentication data leaving blank its charts controls In this case the chart of ONVIF detected devices will display all compatible cameras that do not require
28. PROGRAMMING MANUAL INTEGRATED PANELS KSI1000016 300 KSI1100016 300 KSI1000048 300 KSI1100048 300 KSI1100128 300 14113 tii A m LLERS me mE 4 a 4 a AAA T oa ZH TH Ta PM ine _ E i E m E T f CE SE T i i i pa I e a I g n E E sisas i i DODD De 06d TTETTETTTETTT SSeS oi Y WD PH EM d gt oas DOO CE A A A E d W ON J ON m Ll a P iS dedo ll 2331209 J A A A A A innovation NAO O AAA A A A A A NE SN 3 CSENER Ae SiG GU RE ORINE SOEIWARE S e e riada 3 MAIRUMENW AND WINDOW S MEN ee e a E A E cc e Urea 4 MGM MU see e cn o A A ene a E A 4 WIDOWS MSE e a a a E A E E E a 6 CREATING A NEWACCOUNTAND STARING THEPRROCRAMMING Ta a a ON 8 DESSRIPMO NO REROGRANMIMING HRA GES at con act 9 o E whore lope rm ee rte cl nnd rn tr ee E Ra ed ct ese een Sad tie eel na A 9 AMIRO a E TO 10 SR A a a O Oe At a ae Aa A A A A 11 DO SA E A NN 16 A a A arenes rN Nene eae Ne ee ears nO an Peet ata E Sa IO ae 1 elders aN A at Ane a aN 16 REN PRE Ale Sutteienn ten AAA ii DO aaa meen E O 18 LSO o es e AAA a a leer sen ected lee Mewar tomatoe vast Nusrat hres Demat edt nota te tia War Shae E eter see ae 18 BUSSFERIRPRRERA ES T a ro ia ad E Ne anton none 19 AER o eee a a a E A a perenne Mena det ate rn ne TT 19 AD ALA A A O 2 107414610 M5 91992 1910 0 es Sees ae a a a a Mier ne hts a an tern E
29. RS requires that the devices comply at least with the following constraints on firmware DEVICE FIRMWARE VERSION BUILD FIRMWARE gemino BUS 01 00 xx 992 lares all models 01 01 xx 657 To enable remote assistance following parameters should be configured OPTIONS PAGE e Select the Enable Remote Assistance on GPRS option Remote assistance settings e Set the value in minutes of the session timeout Enone remote apastanoe on SRS The session timeout indicates how long the Panel is accessible 50 Remote session bmeout min remotely on GPRS channel This timer is started immediately after user enabling and rearmed for each start service acceptance by the installer 11 Remote assistance does not require any modem or additional device lt just requires an up to date basis software 53 lares programming manual A e Ms EN aika kid EW io Facel l j ee 0 E T eed ee 5h Wam EEE e hy Tir ey D rri lee 1 4 a Farol Ear airada Uso A Libere Era Hire E firir carta Timpe Era E Costrolled subat tamper reier foe e Parnes ssip Ler ree EPA pra lie T tramite asaateece co LATE habis More E Porte Macho Saperen laura PERIPHERALS BUS GEMINO PAGE e Set APN in SIM dedicated section e Set the ports for the GPRS communication e If you want to reach a Panel through a dynamic DNS service rather than using IP DDNS select Dynamic DNS Settings e Ensure that the network operator provides a public IP addres
30. Remote Assistance by User session Installer Pin although disabled during Remote Assistance is automatically considered enabled lares programming manual END OF ASSISTANCE SESSION BY THE USER This operation can be performed in several ways 1 Activation by SMS The SMS body should contain user code M m 0 no spaces between text characters Example 147258m0 2 Activation by Keypad Enter PIH U Main Menu Advanced Menu Remote Ass os ENTER YES ESC NO Upon completion will display the Remote Assistance status in the first row of the display 3 Disabling by Protocol For third party applications that want integrate themselves with lares Panels NOTES Before starting the remote assistance it would be better to make preliminary check Check that the communication ports from gemino and installer pc side are open in the worst case both inbound and outbound that is a port mapping has been made Configure ports keeping in mind that communication with Ksenia peripherals uses the UDP protocol Verify that the IP addresses assigned to the SIM CARD are actually public IP addresses sometimes in case of prepaid SIM see Vodafone public IP are not assigned Such verification must be completed even if pc installer side Uses a wireless device for the connection Increase the timeout and communication attempts on the options page timeout at least gt 8 seconds attempts at least gt 3 lares programming manual 56 57
31. SMS you should add in the recipients column the programmed numbers in the phone book In the case of voice messages you should also select the voice messages attached to the corresponding event lares 50 programming manual 51 EXAMPLE 3 ARMING WITH COMMAND ZONE Let s further say you have defined in the Arming page an arming mode called Total Arming 2 Suppose that you want to use a zone to make a partition arming simply associate with the Real Time Zone Alarm the Total Arming 2 mode CA In order to maintain conformity with norms listed on page 73 this option must be disabled DETAILS OF PROGRAMMING PARAMETERS Programming status of events is summarized in a table that displays the actions on outputs and timer the recipients notified and its associated voice message and arming mode enabled at the time of the occurrence of each event In this table events can be sorted by each column just clicking on the header of the column you want to use for sorting Displayed columns can be customized by clicking with the right mouse key on the headers ot the table By enabling the Groups Event option you can organize events for type In addition you can display only one subset of events by filtering by name This can be done by inserting a string on Filter The Show Descriptions option allows you to display labels for the programmend outputs zones contacts and so on The actions programmed for each event can be modified from the Detai
32. System with a code or patrol Tag Input time starts The notice of scheduler is started The exit time is started ENDS WHEN The status change or the zone is disarmed The status change The zone is reincluded The status change or the zone is armed The zone comes back to rest The zone is disarmed The chime is disabled End of patrol period or System rearming Input time expires or is stopped by disarming the partition The notice of scheduler is stopped The exit time expired or is stopped lares programming manual Contact ID EVENT CODE 130 137 570 388 600 400 SIA EVENT CODE BA BR TA TR BB BU BT BR UA UH CL OP GG Associated Partition 00 if the zone belongs to more than one partition Partition number CCC Zone number 000 KIND OF EVENT Missing Peripheral Peripheral restored Peripherals tamper Tamper restore Missing wireless Peripheral Restore of wireless Peripheral Wireless peripheral tamper Wireless Peripheral tamper restore Start Timer Stop Timer Panel tamper Panel tamper restore Missing net Net restore Low battery Restore of low battery Missing Ethernet Ethernet restore Missing PSTN PSTN restore Loss GSM net Restore of GSM net Start maintenance Stop maintenance CATEGORY Peripherals Timers Altri eventi Power supply Power suppl
33. Tag is active PATROL If this option is selected the Tag can make disarming operations but the partition will automatically be rearmed at the end of the time of patrol programmed in the Partitions page see following paragraphs 8 The Tags are RFID devices available on request 9 The code will appear on the keypad display as soon as you approached the Tags set as a Installer Tag This feature is particularly useful in the case of a large contractor with personnel to their dependencies at the end of the working relationship with a particular person is simply the withdrawal of key supplied to the person himself without the need to brush up on all facilities for editing Installer codes of access to systems lares 36 programming manual 37 ARM ONLY If this option is selected the Tag will not perform disarming NO ACTION If this option is selected when the key is approached to the volo reader is only activated the scenario that corresponds to the event Recognized Code without allowing to activate the scenarios associated with the reader or enter the menu if approached to the ergo keypad This option is very useful if you want to use code to do one action anly example output activation to open a door LOAD IDs SEND IDs By pressing this button you can load IDs from the Panel and save them on the software database This action in conjunction with the SEND IDs button will allow you to clear or replace the panel wi
34. The configuration of the device is not removed so it can be reused on a different device e g If you want to replace a device e Scrolling between the devices registered in the system and possibility to remove the device from your System without deleting the configuration that can be assigned to a new device connected on the BUS and not yet registered e Delete remove devices from lares panel programming Unlike the command Free in this case is also cancelled the programming defined for this device lares programming manual ergo Keypads Scroll the ergo keypads e Partition Mask e Scroll the partitions and ability to enable the keypad for the selected partition e Information at rest e Date and time e External temperature e Internal temperature e GSM Operator e Partition status e Zone status e Keys and Scenarios e Key O Description e Key O with PIN e Key O without PIN e Key 1 Description e Key 1 with PIN e Key 1 without PIN e Key 2 Description e Key 2 with PIN e Key 2 without PIN e Key 3 Description e Key 3 with PIN e Key 3 without PIN e Key 4 Description e Key 4 with PIN e Key 4 without PIN e Key 5 Description e Key 5 with PIN e Key 5 without PIN e Key 6 Description e Key 6 with PIN e Key 6 without PIN e Key 7 Description e Key 7 with PIN e Key 7 without PIN e Key 8 Description e Key 8 with PIN e Key 8 without PIN e Key 9 Description e Key 9 with PIN e Key 9 without PIN
35. able the keypads to show the calls status i e in case of duress disarm TRIES Number of call attempts that the device performs on each configured number before the message is deleted also in case of non receipt of confirmation REPETITIONS Represents the number of voice message repetitions during the same call REMOTE ASSISTANCE SETTINGS To program these options please refere to the Remote Assistance paragraph lares programming manual INSTALLER DATA Data that will be show on the ergo keypads pressing the Enter key in idle state DATE AND TIME In this section you can set the date and time using the E Set button Daylight saving will enable the automatic switching of summer winter time checking this option will show a panel in which date time changing can be programmed NOTE To schedule the date and time you must enter a valid user PIN SCHEDULER The scheluder is useful to arm disarm the system using arming modes or on a partition basis lt can also be used to enable disable user groups both codes and RFID keys For example in the case of anti intrusion system installed in an office you might schedule the total insertion of the System throughout the day on 25 December for normal working days you could schedule the disarming during work hours and automatic rearming in other times Graphics mode is easy to guess to add a daily pattern press the O Add button or drag the corresponding icon from the Palette
36. ac rence te nev pectic ee oom han renee od Orla re en ra a enn OE ain ements 57 EVENT A TI ee mun ein Ue Nena ID een en 57 FATE TVA tetona in ee Ning egies hata ain Sen dt td a 57 ergo DRE Ab tae CRAIN INAIIN Goa AEN a At cent a e ro 58 PROG RAMIS UN tdo tidad adosado 71 SERIES AO NS a e AO tonada 73 lares programming manual INTRODUCTION The programming platform and central management tool is basis this SOFTWARE can be downloaded from our website htto www kseniasecurity com The FAQ section of the site provides numerous videos showing the device s programming basis introduces innovation because it is based on the most modern technologies Thanks to JAVA support basis can be installed on any computer running Microsoft operating systems Apple Linux or Oracle does not require enormous computing power nor third party software basis has been developed considering the needs of those who use it the installer of security systems the end user of the system the monitoring stations each person will have only what it needs basis ensures complete Ksenia device programming and real time control all distributed under a free license then free to download GENERAL STRUCTURE OF THE SOFTWARE basis is modular and based on a main engine and expansion modules installed and updated each independently Once installed the SOFTWARE will update automatically without the need for manual intervention pitiful uninstalls of software packages and c
37. added to the system The number of programmable sirens depends on Panel model To add a siren drag the corresponding icon from the palette to the page or select it by pressing the 9 Add button in the main menu Let s see its programmable parameters LABEL The label is the description that you want to give to the siren and will be used as a label in other programming pages shown in the events log and used as a string by SMS or e mail alerts Each device on the BUS hence also the radius indoor siren is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS OUTPUTS BUZZER AND LAMP The siren is handled by the system as an output To activate both light and acoustic signaling we will assign an output in the Buzzer and Lamp window When this output is activated such as when an alarm event is fired the siren starts sounding and flashing ONLY LAMP Outputs can also be assigned to the blinker only Only Lamp MAXIMUM ALARM TIME Maximum time of activation of acoustic signal and siren light for cutting wires USE EMERGENCY LAMP If this option is selected when power failure occurs the siren turns on the power LED lighting up a medium sized room Caution you must install
38. ail alerts Each device on the BUS hence also the ergo LCD keypad is identified by a serial number with 6 digits If this number is known we can add it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS BACKLIGHT In this section you can adjust the level of backlighting of the keypad Select the Eco mode if you want the keypad backlight disabled in stand by VOLUME In this section you can adjust the volume level of keypad speaker M1 M2 TERMINALS ZONE OUTPUTS Programming logical zones or outputs to be assigned to the terminals indicated on your keypad with the name M1 M2 If a Terminal is assigned to a zone it obviously cannot be assigned output function IDLE INFORMATION Information displayed on the keyboard in idle state Date and Time enables disables the display of the date and time on the second line of the display GSM service enables disables the display of the operator and of the GSM signal on the second line of the display if a gemino GSM Communicator is configured on your system External temperature enables disables the display of the outdoor temperature on the second line of the display if at least one imago siren is configured on your system Internal temperature enables disables the display of the indoor temperature
39. arming mode at the current event Output e Output e Assign outputs to the current event e Action e No action e Enable e Restore e Toggle lares programming manual KIND OF EVENT Zone alarm Zone restore Sabotaggio Zona Ripristino Sabotaggio Zona Excluding zone Including zone Fault or zone masking Fault restore or Masking Realtime zone Restore of realtime zone Partition arming Partition disarming Chime on Partition End of chime on Partition Patrol on Partition End of patrol on Partition Partition pre alarm Restore Partition pre alarm Partition notice End of Partition notice Exit time End of exit time 65 CATEGORY Zone Events Partition Events SUMMARY TABLE OF START STOP EVENTS events that have a specific start and end point The table refers to the lares with 1 5 XXX firmware version RECURRENCE Number of Zones Number of Zones Number of Zones Number of Zones Number of Zones Number of Partitions Number of Partitions Number of Partitions Number of Partitions Number of Partitions Number of Partitions OCCURS WHEN An armed zone is violated A zone Is sabotaged or put in blackout The zone is excluded A zone is masked or the inactivity time expires A disarmed zone is violated or a violated zone switch from armed to disarmed The zone is armed The chime is enabled Disarming
40. ase the battery life of the sensor ALARM CYCLES Number of alarm cycles that can be generated by the zone Alarm cycles are reset at each zone arming INACTIVITY If the zone is never violated for the programmed time in minutes the zone masking event will be generated passive control of masking PERIPHERAL AND TERMINAL This section displays the device associated to the zone and the terminal where the sensor must be physically connected LINKED EVENTS This section provides a list of events related to the selected zone By selecting one or more events is possible to program the actions from the details window The planned actions will be executed upon the occurrence of the event Refer to the Scenarios paragraph for programming details lares programming manual 15 16 AND ZONES On this page you can program the structure of AND zones Putting zones in AND among them means that alarm will be generated only if all parts that belong to the structure are violated To add a zone in AND structure press the e Add button or drag the corresponding icon from the Palette in programming page For each structure there can be programmed two zones First zone and Second zone or three also using the Third zone field TIME WINDOW Time in seconds during which the violation must occur for the two or three planned zones in the structure so that they actually raise the alarm MAJORITY This option i
41. authentication 2 Ascan is done by providing user name and password in the appropriate fields In this case the chart of ONVIF detected devices will display all compatible cameras that comply with the authentication criteria entered and all cameras that do not require authentication ETHERNET For expert users This page is only available for lares16 P lares 48 IP and lares 128 IP It contains the network configuration parameters Default values for lares are 192 168 2 90 static IP address netmask 255 255 0 0 default gateway 192 168 2 1 BOARD NAME NETBIOS name Is the name by which you can identify your board on the network factory setted as lares_board This feature is available only on Windows networks ENABLE DHCP By enabling this option the board will automatically configure the network parameters only if a DHCP server is present in the network SMTP The checkbox Enable SMTP will enable the panel to send emails using the SMTP protocol E MAIL FROM Input here the sender name eg Alarm System Some servers may require the insertion of a valid email address e g servers that do not require authentication SERVER Set the name of SMTP server e g mail provider net USER NAME Set the name used to access on SMTP server PASSWORD Set the authentication password 10 We recommend that you contact your network administrator for setting these parameters before connecting the panel on the network in order to avoi
42. be also displayed if a Loquendo USB key is connected to the PC CHECK FOR UPDATES The Check for updates button enables to check if there are any software updates Performing updates requires that the PC is connected to Internet Simply follow the instructions shown on the screen to keep basis constantly up to date PLUGINS The Plugins folder contains settings for managing basis software modules and update management the Available Plugins tab shows the available and not installed software modules In order to install a new module select it and press the install button In the Installed tab you can manage your currently installed modules checking the status features and eventually disable it The settings menu shows a link to the software update Center you should not edit this parameter and you can change the update checking settings INFORMATIONS The Information button opens a window with the version of SW and SW related additional information 2 LOQUENDO TIS it is a LOQUENDO S p A trademark More information about Loquendo TTS functionality is available in the manual on the USB flash key containing the license for use of the product 3 Specifically it requires that your PC will be able to reach the site www kseniasecurity com also indirectly through access to a LAN lares programming manual CREATING A NEW ACCOUNT AND STARTING THE PROGRAMMING To create a new customer simply press the button a New
43. by the sensors themselves we recommend that you test the system instead of using the real time 2 To program a command zone associate it to the partition that will arm disarm then associate the arming mode to the real time of zone corresponding event in the Scenario page 3 Analogic zones may be attached only to Terminal 1 of auxi expansion modules Analogic zones do not generate alarms or tamper but events associated with the input voltage level FIA In order to maintain compliance with the norms listed on page 73 the Command and Analogic options should not be selected ARM MODE ON ACTIVATION If you selected the processing mode command you can use this menu to select the arm mode to execute at the moment of the zone violation IQ In order to maintain compliance with the norms listed on page 73 cannot be selected no insertion mode ARM MODE ON RESTORAL If you selected the processing mode command you can use this menu to select the arm mode to execute when the zone comes back in stand by IQ In order to maintain compliance with the norms listed on page 73 cannot be selected no insertion mode lares 1 1 programming manual 12 LABEL The label is the name that is associated with the zone This is used as the identifier in the programming pages as a string by mail or SMS dialer and automatic generation of voice messages Moreover this label is displayed in the event log logger BALANCE The choices
44. confirmation of executed command CONFIGURING FUNCTION KEYS You can configure up to 7 different actions associated to the keys of wireless remote control In addition to associate a possible arming previously programmed you can program the function keys outputs activation SMS sending mails from the Scenarios page see following paragraphs PARTITION MASK Assign the partition on which the remote control can operate lares programming manual PHONEBOOK You can enter up to 100 contacts to whom can be sent reports To add a contact IP receiver to the phonebook press the O Add button or drag the corrisoonding icon from the Palette Before inserting data will be asked if you want to add a phone contact or a IP receiver NEW CONTACT NAME The name associated with the phonebook position NUMBER Phone number optional If this field is not programmed the phonebook position cannot receive SMS or voice calls NOTE Insert the international prefix e g 0039 could affect the proper functioning of the device E MAIL E mail address optional If this field is not programmed the contact position cannot receive emails OPTIONS CANNOT RECEIVE SMS Select this option if you don t want the number to be alerted via SMS for example if it is a landline phone number CANNOT RECEIVE VOCAL MESSAGES Select this option if you don t want the number to receive voice calls ENABLE CALLER ID If this option is selected t
45. d conflicts and malfunctions even on other apparatuses lares 40 programming manual 41 ENABLE SSL Select this option if the mail server requires encryption e g gmail In this case you must set also the SMTP port eg 465 ENABLE WEBSERVER This option enables the integrated web server ENABLE HTTPS In case you want to use an encrypted communication simply select this option In this case the adaress will be https lt panel name gt lt HTTPS port gt LIMIT NUMBER OF SIMULTANEOUS ACCESSES Selecting this option is limited to 5 the number of IP addresses that can access the WEB resource WEBSERVER USER NAME Default admin Set the username for the web server login PASSWORD Default lares Set the password for web server login authentication PORT Default 80 In this section it is possible to program the communication port HTTPS PORT Default 443 This section is available only if you select the option Enable HTTPS Allows the use of encrypted communication ENABLE PING By selecting this option your board will resoond to ping requests coming from the network ENABLE UDP DISCOVERY POLICY By selecting this option the panel automatically appears in the devices list but only if the PC is on the same subnet Otherwise you will need to set the IP address manually to communicate with the panel In case of PC and Panel are in two different subnets you will need to access the Remote Assistance sec
46. device in the system hence also the poli nanus Magnetic Contact is identified by a serial number with 6 digits You can insert it in Serial number field or you can check the Assign serial number from keypad box and then from the ergo installer menu you can assign automatically the serial number to the device MAGNETIC CONTACT Input here the Logic Zone previously programmed to be associated with magnetic contact AUXILIARY CONTACT Input here if desired the Logical Zones previously programmed to associate to auxiliary contacts Auxiliary zones are not available on nanus Micro Magnetic Contact so this section should not be programmed SUPERVISION INTERVAL Maximum amount of time that elapses between two transmissions If the panel does not receive any data over an interval of twice the supervision interval it will raise a missing peripheral event lares 2 9 programming manual 30 unum INDOOR MOTION DETECTOR Up to 64 unum wireless motion detectors can be added to the system To add a motion detector contact drag the corresponding icon from the palette to the customer manager page or select it by pressing the O Add button in the main menu After choosing wireless tab unum indoor motion detector and OK buttons the programming page will open LABEL In the label field you must write the identifier name for the motion detector It will be used as a call sign in other programming pages shown in the event log logg
47. dule the activation mode of the user groups codes and or keys associated to the scheduler There are 4 distinct user groups activated and deactivated in 16 different programmable mode MODE Description of the user group activation mode editable with a double click on the desired box In each mode you can define 3 different states for each user group NO ACTION When the mode is enabled the group status is not changed io ENABLED When the mode is enabled the group is active and codes keys are valid _ DISABLED When the mode is enabled the unit is off and the codes keys are not valid Any unused groups can be left in the No Action mode Default basic programming already includes two predefined modes activating and deactivating of all groups NOTE If you use a PIN code or a key belonging to a disabled group the system generates the reporting of incorrect PIN lares 34 programming manual 35 CODES In this page user codes can be added Please note that here you will just add a new user code but not the PIN The PIN will be changed from the keypad To add a code press the O Add button or drag the corresponding icon from the Palette Using the codes you can restrict operations on the system There are 3 levels of access 1 Access by any person without entering any code 2 Access by user entering user codes 3 Access by the maintainer entering installer code Only 1 installer code is available in
48. duo wireless repeater can be added to the system To add a wireless repeater drag the corresponding icon from the palette to the customer manager page or select it by pressing the O Add button in the main menu After choosing wireless tab duo wireless repeater and OK buttons the programming page will open LABEL In the label field you must write the identifier name for the duo repeater It will be used as a call sign in other programming pages shown in the event log logger and used as a string by SMS or e mail alerts Each device in the system hence also the duo Wireless Repeater is identified by a serial number with 6 digits You can insert it in Serial number field or you can check the Assign serial number from keypad box and then from the ergo installer menu you can assign automatically the serial number to the device 3 poli nanus MAGNETIC CONTACT Up to 64 poli nanus wireless magnetic contacts can be added to the system To add a wireless magnetic contact drag the corresponding icon from the palette to the customer manager page or select it by pressing the EJ Add button in the main menu After choosing wireless tab poli magnetic contact and OK buttons the programming page will open LABEL In the label field you must write the identifier name for the wireless magnetic contact It will be used as a call sign in other programming pages shown in the event log logger and used as a string by SMS or e mail alerts Each
49. e auto bypass does not exclude tamper and masks The zone is automatically un bypassed on next disarm FIG In order to maintain compliance with the norms listed on page 73 this option must be used only with the scheduler AUTO UNBYPASS If this option is selected the zone is automatically bypassed if violated when arming As soon as it comes back to stand by it is automatically un bypassed FIG In order to maintain compliance with the norms listed on page 73 this option must be used only with the scheduler lares programming manual ATTRIBUTES CHIME If this option is selected when the zone is violated with disarmed partitions it generates beeps for 5 seconds on all the keypads enabled on the same partitions ALWAYS ACTIVE If this option is selected when the zone is violated an alarm will be generated regardless of the arming of the partitions associated with the zone TEST If this option is selected the zone will only generate events in the log without generating any alarm PIR ALWAYS ACTIVE Only on wireless unum zones If this option is not selected the sensor detects any movement only when the system is armed activating this option the analysis performed by the sensor detection is always active Option to use in case you want to use the unum wireless sensor in home automation applications After arming there might be a maximum delay of 30 seconds before the sensor is fully operational STANDARD INTENSITY OF THE SIGNAL On
50. e installer PIN default 123456 or use a RFID key with installer attribute Refer to the keypad manual for the use and functions of buttons and circular scroll This section shows the programming tree About the meaning of the parameters but specific descriptions you can simply reference the preceding paragraphs since both the order of the menu and used terminology is the same as that used on basis software NOTE Log in as Installer is inhibited when partitions are armed Also log in as Installer both with key and code must be enabled by a main user in the user menu under Install Permission setting to ON If enable is set to OFF the use of the installer code is inhibited considered wrong code INSTALLER MENU STRINGS To access a sub menu in programming phase you have to tap the ENTER key Event Log Verified events scroll starting from last one Scroll in detail the informations date time generator about the selected event Programming See following paragraph Program from USB Allows loading data from USB key connected to the Panel Language Scroll among available languages IP Address IP Address of Panel xxx xxx XXX XXX Failure status Scroll the faults in progress Battery status Devices batteries status Zones status Scroll the zones and display their status Display the value of the resistance in ohms read in the selected zone If the zone is analogic the voltage appears at the zone input
51. e next button you can select the device you want to update where is also shown the latest firmware revision available Performing Updates to basis the PC will also be updated with the latest firmware released for each device in the list The firmware update requires a few seconds to from a few minutes depending on the currently selected device lares programming manual DEVICE DATA ADD The Add button creates a new item in the active window in example if we are in the Phonebook page by pressing this button we will be able to add a new number in the phone book If we are in the Zone page we can add a new zone and so on It can be used in place of the buttons in Palette DELETE The Delete button clears the item selected in the active window in example if we are in the Phonebook page by clicking this button the selected contact will be deleted If we are in the Zone page we will remove the selected and so on REFRESH Use this button to refresh the current view of the active window TEMPLATES This button allows to toggle from the simplified programming to the total one and vice versa COMMUNICATION LOAD ALL The Load all and Send all buttons uploads sends all programming to devices These two buttons are also available in the Navigator window SEND ALL LOAD PAGE The Load page and Send page buttons loads sends the entire displayed page to the device example Phonebook SEND PAGE LOAD T
52. eck this box if the event should reset the alarm outputs i e relais for disarming events In order to maintain the GRADE 3 the Panel must be connected to the alarm receiving center exclusively through GPRS or ETHERNET EK with SIA DC 09 communication protocol using the gemino GSM dialler ATS4 In order to maintain the GRADE 2 the Panel must be connected to the alarm receiving center via text to soeech communication using the pontis PSTN board ATS2 Each event must be associated with a transmission EN lares programming manual 52 REMOTE ASSISTANCE With all lares Panels you can make remote assistance via the gemino BUS Communicator using the GSM GPRS network for data transmission figure 19 In addition for lares 16 IP lares 48 IP and lares 128 IP it is possible to perform remote support on Ethernet To enable remote assistance on Ethernet simply check the Use Remote Communication on Ethernet option and enter the address in the provided space Enabling remote assistance on GPRS requires a greater number of steps that will be described below 30 GSM GPRS lares COMMUNICATOR ISP WEB ETHERNET PC PHYSICAL LAYER The communication over GPRS is made class 10 3R2T asymmetrical multislot that is 3 timeslot in receiving 43200 bps max and 2 timeslot in transmission 28800 bps upload The gemino BUS interfaces the lares Panel through KS BUS FIRMWARE LAYER Performing remote assistance on GP
53. er and used as a string by SMS or e mail alerts Each device in the system hence also the unum Magnetic Contact is identified by a serial number with 6 digits You can insert it in Serial number field or you can check the Assign serial number from keypad box and then from the ergo installer menu you can assign automatically the serial number to the device ASSIGNED ZONE Logic Zone previously programmed to be associated with the detector OVERSEEING INTERVAL Maximum amount of time that elapses between two transmissions If the panel does not receive any data over an interval of twice that of overseeing raises a missing peripheral event nebula SMOKE DETECTOR Up to 64 nebula wireless smoke detectors can be added to the system To add a motion detector contact drag the corresponding icon from the palette to the customer manager page or select it by pressing the O Add button in the main menu After choosing wireless tab nebula smoke detector and OK buttons the programming page will open LABEL The label is the description that you want to give to the smoke detector and will be used as a call sign in other programming pages shown in the event log logger and used as a string by SMS or e mail alerts Each wireless device hence also the nebula smoke detector is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is not known you can check o
54. er to maintain compliance with the norms listed on page 73 this option must be enabled WARNING Select this option if you want to enable acoustic warning on the keypad during the time of notice arming with scheduler FIA In order to maintain compliance with the norms listed on page 73 this option must be enabled CHIME Select this option if you want to enable acoustic warning on the keypad associated with chime attribute zones NEW SOUNDS Select this option to set the short sounds 1 beep every 5 seconds during the input and output time rather than the continuous beeps CAPSENSE SENSITIVITY In this section you can set the sensitivity for detecting key touches MACRO FUNCTION DESCRIPTION Enter the description that you want to give to the scenario associated with the key which will be used as a label in the other pages shown in the events log and used as the SMS Dialer string ENABLED You can bind a key to the desired arming mode Select Enabled if you want to activate the corresponding button with PIN entry select No PIN if you want to enable the function without putting the PIN but simply pushing for three consecutive seconds the corresponding key on the keypad macro function The rest of the parameters outputs activations timers etc have to be programmed in the Scenarios page see following paragraphs DISABLE AUTOMATIC SCENARIO EXECUTION When you digit a PIN the keypad runs the shown scenario after 3
55. ery 10 SMS sent CHECK THRESHOLD Is the threshold expressed in Euro or in local currency below which gemino generates the warning of credit deficiency and performs the switching of SIM if there are two SIM GSM SERVICE PROVIDER Select an operator from among those proposed to enable the credit check DESTINATION LIST Select Phonebook numbers that will receive reports of residual credit and SIM expiry To add an entry press the green button Up to two recipients can be added EXPIRATION CHECK SIM EXPIRY DATE Insert the SIM expiry date PERIOD Is the time in days in which the deadline Is stretched at each SIM recharge If set to zero the SIM expiry check is not performed GPRS OPTIONS APN SETTINGS Is the access point to the GPRS network this parameter is provided by GSM GPRS operator This parameter is required only if gemino is programmed to remotely manage the system via GPRS For more information please refer to the REMOTE ASSISTANCE paragraph lares programming manual B ergo LCD KEYPAD ergo LCD keypads can be programmed in the system To add an ergo drag the corresponding icon from the Palette to the programming page or select it by pressing the O Add button in the main menu Let s see its programmable parameters LABEL The label is the description that you want to give to the keypad and will be used as a label in other programming pages shown in the events log and used as a string for SMS or e m
56. f you want the output to generate a voltage between 0 and 10V maximum current of 20mA when enabled The voltage is OV when output is in stand by Program the output voltage with the cursor in the section Analog Value NOTE The analogue outputs can be mapped only to terminal 5 of auxi expansion modules TIMES ON TIME Time in seconds for which an output programmed as MONOSTABLE remains active in the occurrence of an event CYCLE TIME Is the sum of ON time plus a minimum time for which you want to keep the output off REMOTE CONTROL Select this option if you want to control the output manually CONTROLLED This option is valid only for the relay output If enabled the Terminal A needs the end of line resistor The end of line resistor must have a value of 1OKQ In case of tampering the event Controlled output tamper is generated PERIPHERAL AND TERMINAL This section displays the device associated to the output and terminal on which the output must be physically connected EVENTS MANAGEMENT Events acting on the output status are listed in Activated by Deactivated by and Toggled by boxes To add a new event in one of these boxes simply drag it from the Details window To delete an event from a box double click the event you want to delete By pressing the button Clear events you can clear all events that acton the output The association of outputs to events can also be made from the Scenarios page see
57. he Load and Send buttons loads sends only the selected item to the device example a Phonebook number SEND lares programming manual WINDOWS MENU The Windows bar figure 3 contains buttons allowing the user to enable the main windows of the software To activate a window just click with your mouse on the corresponding button ral de Comoras Were jog Bok da A eng Beg Ls e i a Palito Cita Fre lia imga aireado Chel Fan Alok A a CUSTOMER LIST The Customer list window allows control of customers and allows the database management Using this window you can create edit delete and manage customers by clicking with the right mouse button on the customer name Double clicking on the customer name will open the programming overview called Customer manager DETAILS This window shows the programming details of the selected event PLUGPLAY This window shows the devices connected to the PC and detected by the platform Displays the communication port serial port the connected device the customer code associated with the database the description that allows us to identify different products and firmware Version of the device WELCOME In this window are presented the main functions of the software and the latest news in the Ksenia world UTILITIES PALETTE y The Palette offers the major common components of the current device Simply drag the desired item in the main window to insert it into the pr
58. he arming modes associable to the events in the Scenarios page or to numeric keys of the ergo LCD keypad or volo reader Just press the O Add button to insert a new arming mode Depending on the system model up to 64 different arm methods can be defined od In case of zones in alarm arming the system will be possible only excluding these zones The arming will not under any circumstances be possible in case of tamper fault events MODE Is the description that you want to give to the arming mode used as a label in the other pages and displayed on the ergo keypad when the mode is active To add a new arming mode just press the button O Add Default basic programming already includes three predefined modes total arming of all partitions total disarming and night mode partial arming For each arming mode you can define the state each partition will be put in when the mode is enabled To change a mode programm simply move in the mode partitions grid up to the cell that you want to edit and click the left mouse button to get the desired programming If you want to modify the programming of all partitions for a particular arming mode just click the button to the left of the description The 5 possible States are NO ACTION When the mode is enabled the partition status is not changed ARM WITHOUT DELAYS When the mode is enabled the partition in armed and both of imput and output delays are reset ARM WITH DELAYS When
59. he device in case of incoming calls from this number raises the corresponding event of recognised caller but the incoming call is rejected SEND CONTACT ID When this option is selected the alerts are sent through the Contact ID Protocol PRIORITY ON GSM PSTN For each number you can program which communication channel must be used first priority on GSM or on PSTN Non priority channel is automatically used as the reserve CONTACT ID To send the Contact ID you need to enter the customer code of 4 digits Usually provided by the Central Monitoring Station All event codes are preprogrammed CUSTOMER CODE Program the 4 digit customer code for use in the transmission of Contact ID 6 The maximum number of configurable contacts depends on the model of the lares 7 This function is particularly useful if you want the simple call coming from a given number can activate a policy panel arming closure of a relay at no cost lares 32 programming manual 33 NEW IP RECEIVER RECEIVER DESCRIPTION Name associated with the receiver RECEIVER ID NUMBER SIAIP DCO9 Receiver identifier 6 hexadecimal digits maximum TRANSPORT ID SIAIP DCO9 identifier for the Panel used with the current receiver 12 hexadecimal digits maximum IP ADDRESS IP address of Receiver PORT Remote port on which the receiver listens PROTOCOL Application protocol used to format the data field of the transport protocol SIAIP DCO9 Contact ID SiaLeve
60. l model To add a reader drag the corresponding icon from the palette to the page or select it by pressing the 5 Add button in the main menu We see its programmable parameters LABEL The label is the description that you want to give to the reader and will be Used as a label in other programming pages shown in the events log and used as a string for SMS or e mail alerts Each device on the BUS hence also the volo proximity reader is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS IDLE INFORMATIONS GREEN LED ON If this option is selected the green LED will turn on to confirm the system disarm Otherwise if you do not select this option the reader will activate the red LED only to confirm the system arming allowing also for colorblind users to check the system status LED on system armed LED off system disarmed LED TIMEOUT Time in seconds during which the LED is activated to confirm an operation correctly performed lares programming manual TAMPER SENSITIVITY In this section you can adjust the sensitivity level of tamper accelerometer ARMING MODES AND LED In this section you can assign a specific configuration Arming Disarming Scenario
61. l3 APPLICATION ID Panel application protocol identifier Contact ID SiaLevel3 Used with the current receiver OPTIONS SIAIP DCO9 protocol options AUTOMATIC BACKUP Communication to this receiver in case of failure is repeated toward the backup receiver PRIORITY ON BACKUP RECEIVER The communication is sent FIRST to the backup receiver and repeated in case of failure to this receiver PRIORITY ON GPRS When selected this option sets the priority of the channel GPRS communication instead of the ethernet channel USE TIMESTAMP When selected this option sets the date and time information on the data package TRANSMIT OVER TCP Sets the use of TCP instead of UDP for sending alerts lares programming manual BACKUP BACKUP RECEIVER Backup receiver of the current one BACKUP PERIOD S Time in seconds on which you send notifications to the backup receiver since the main receiver is off EVENTS MANAGEMENT List of events that will be reported to the current receiver To add a new event to this box simply drag it from the Details windows To delete an event from this box double click on the event you want to delete Pressing the Clear events button will delete all events in this box Pressing the Default button a predefined set of events will be added to this box The events listed in this box can be also programmed in the Scenarios page see following paragraphs USER GROUPS On this page you can sche
62. ls window acting directly on the table or by programming panel that can be enabled by checking the Event Detail box Thanks to multi select feature you can quickly change the attributes for a group of multiple events Let s see the meaning of each field OUTPUTS ON Select the outputs up to 8 that can be activated upon the occurrence of a specific event OUTPUTS OFF Select the outputs Up to 8 that can be deactivated upon the occurrence of a specific event OUTPUTS TOGGLED Select the outputs which can change status upon the occurrence of a specific event i e If the Output is at rest is activated if it was activated returns to rest ACTIVATE OUTPUTS This option allows to choose whether the programmed outputs must be always enabled enabled only when there is at least one partition armed or only when all the partitions are disarmed NOTE To select the output function mode activation deactivation and toggle press the icon to the right of the output name Every output can be used for any set of events l e an output can be set if at least one partition is armed and reset only if ALL the partitions are disarmed Follow these steps e Set the output in all the Armi partition columns e Reset the output in all the Disarm partition events e Provide taht the output is programmed as bistable output and the Remote control check is de activated This type of operation must occur under the following conditions e The ou
63. ly on wireless unum zones Normal Immunity HIGH INTENSITY OF THE SIGNAL Only on wireless unum zones If this option is selected it introduces an higher immunity threshold in the detection analysis lares programming manual 13 14 ENTRY EXIT LOGIC ee ha IA as Se O LL LAA AA AS Figure shows an hypothetical situation of entry into a dwelling at which the control panel of the system is accessible only after intercepting some zones Specifically the volumetric sensor marked with O must be the first to be violated to not raise an alarm then followed by the number 1 and number 2 in this exact order Warning the above also applies if the zones belong to different partitions provided that you have programmed at least one arming mode which arms them all ENTRY DELAY Select this option if you want that violating that zone starts the entry delay or if this is already started will not generates the alarm You can establish a path of entry on multiple levels programming the input level parameter For example with armed partitions planning three levels has the following behavior e When entry delay in active you can break only one level zones above the last zone violated e When entry delay in NOT active you can break only level O zones the first violation starts the delay EXIT DELAY Select this option if you want the zone not to generate alarms when the exit delay time is active LAST EXIT Is the last zone
64. maximum period allowed should not exceed 300 min VOICE DIALLER CONFIRM REQUEST MESSAGE Option to add a voice message at the end of all voice communication in order to invite the listener to press the key to confirm receipt of the message CONFIRM CALL RESULT By selecting this option you will need to confirm the receipt of the call by pressing the button on the receiving phone Otherwise the device will accept the call as failed and proceed with the next number among those configured This option allows you fo listen to the voice message without interrupting the sequence of callls If you enter the key the panel will consider the call ackowledged After pressing the key you will enter the voice driven menu to interact with the Panel see User Manual FIA In order to maintain conformity with norms listed on page 73 this option must be enabled CALL ALL NUMBERS Selecting this option voice messages will be sent to all configured numbers The sequence of calls will stop only after all numbers in the list will acknowledge the calll NOTE The system considers equally valid possible answers from electronic devices e g faxes and answering machines CONFIRM CALL ESIT AND CALL ALL NUMBERS By combining these two options voice messages will be sent to all configured numbe K The sequence of calls will stop only when all numbers listed will have confirmed the call esit by pressing the button HIDE CALL STATUS ON KEYPADS This option will dis
65. n Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a wireless device ASSIGNED ZONE Logic Zone previously programmed to be associated with the detector OVERSEEING INTERVAL Maximum amount of time that elapses between two transmissions If the panel does not receive any data over an interval of twice that of overseeing raises a missing peripheral event lares programming manual 31 opera REMOTE CONTROL Up to 64 opera wireless remote controls can be added to the system To add a remote control drag the corresponding icon from the palette to the customer manager page or select it by pressing the O Add button in the main menu After choosing wireless tab opera remote control and OK buttons the programming page will open LABEL The label is the description that you want to give to the remote control and will be used as a call sign in other programming pages shown in the event log logger and used as a string by SMS or e mail alerts Each wireless device hence also the opera remote control is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a wireless device VIBRAMOTOR Activates the vibration as
66. n of vocal guided menu by calling the telephone number associated with the pontis Through this tool the user can control the panel after entering a valid user code DO NOT CALL ON PSTN FAULT If this option is selected if the pontis detects the phone line failure phone calls will not be executed and the event Communication Failed will be generated imago OUTDOOR SIREN imago outdoor sirens can be added fo the system The number of programmable sirens depends on Panel model To add a siren drag the corresponding icon from the palette to the page or select it by pressing the O Add button in the main menu Let s see ifs programmable parameters LABEL The label is the description that you want to give to the siren and will be used as a label in other programming pages shown in the events log and used as a string for SMS or e mail alerts Each device on the BUS hence also the imago outdoor siren is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS OUTPUTS BUZZER AND LAMP The siren is handled by the system as an output To activate both light and acoustic signaling we will assign an output in the Buzzer and Lamp window When this output is activated such
67. nicator drag the corresponding icon from the palette to the page or select it by pressing the Add button in the main menu Let s see its programmable parameters LABEL The label is the description that you want to give to the communicator and will be used as a label in other programming pages shown in the events log and used as a string SMS or e mail alerts Each device on the BUS hence also the pontis PSTN Communicator is identified by a serial number with 6 digits If this number is known we can it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS RINGS Program the number of rings that the Communicator must be held to answer incoming calls if vocal menu is enabled BYPASS ANSWERING MACHINE By selecting this option the device will answer to phone calls only if a ring is detected and then stopped Allows you to interact with the panel if it is installed on the same line as other devices that answer to calls automatically e g fax lares 23 programming manual 24 DISABLE TONE CHECK Selecting this option will override the controls that the device makes before initiating an outbound call This allows you to interact with the panel if there were other devices that use the phone line e g exchanger VOCAL MENU Enables the activatio
68. nt to activate the TRIAL version of the service works for 15 days It is however necessary to provide the information required for payment at which will reference in case you want to activate the standard service E x pa o E PR PP E PA ee Em Bad km pu At this point you can access your network by typing the host just created on your browser bar or simply you can do a ping to that host without knowing its IP address T a po 44 programming manual PROGRAMMING OF ACCOUNT DATA ON LARES PANEL You can program your account data via basis software or simply via the web server integrated in the Panel DNS SERVICE Enter the DNS service name to which you are registered Example dynDNS com PORT Specify the port number used by the IP Check service Default 80 HOST NAME Enter here the host name defined in the preceding paragraphs Example esempio dynDNS at work com USER NAME Enter here the user name defined in the preceding paragraphs Example kseniasecurity PASSWORD Enter here the password defined in the preceding paragraphs Example 123456 SERVER IP CHECK Enter here the server name on which the Panel will check your IP Example checkip dyndns com PORT Specify the port number to which refers the IP Check service Default 80 After programming these parameters the panel at regular intervals or in cases where ISP assigned IP address to its network were to change will contact the server that pro
69. ogramming data r I OUTPUT Debug trace window generally not of interest to the user but only for SW maintenance me a PROPERTIES Debug trace window generally not of interest to the user but only for SW maintenance NAVIGATOR The Navigator allows you to navigate quickly through the various programming screens of the currently fi W selected device The navigation buttons are only displayed when a device has been selected in all J other cases the window is blank and shows a No available view message because no device is selected When active just double click on an item to access the relevant page To send upload alll programming to the lares or other connected devices use the button Send all Load alll DOCUMENTATION The button opens the folder on your computer in which the manuals have been copied during installation of SW lares programming manual SUPPORT OPTIONS The Options window enables you to manage the advanced options of the software inside the communications tab you can disable automatic detection of devices connected to the PC enable PlugPlay or modify the parameters of communication speed These parameters can be x modified if thereare issues communicating with the device Inside the vocal synthetizer tab you can select the default text to soeech engine in automatic generation of voice messages basis includes a free text to speech engine Loquendo TTS entries will
70. omplicated tricks to ensure full backward compatibility Handling of the variouse features of the software is possible thanks to a graphical interface that is common to all modules and consists of a system of floating windows basis allows to program all Ksenia Security products in one platform binding the devices to the customer from whom you made the installation When opening a session on a client a summary of what is installed and how it is programmed is immediately presented without the need to open several programming softwares All features are accessible through two control bars available on software Main and Windows To move a window simply drag it by holding down the left mouse button on the bar top Moving on the screen a red dashed line will indicate the new location that will take the window as soon as the left mouse button is released 1 In future will be available versions for last generation smartphones lares programming manual MAIN MENU AND WINDOWS MENU At the top you can distinguish the two main sections in which the SW is divided Main and Windows figure 1 By activating the Main tab a menu pops up with icons that allows logical browsing activating the Windows tab pops up a menu that allows the activation of disabled windows MAIN MENU The Main bar figure 2 is divided into several sections within which various functions are grouped into logical units allowing customer and programming pages management
71. on the second line of the display if at least one radius siren is configured on your system Arming status enables disables the display of the arming status on the second line of the display In addition enabling this option you can see the armed partition details by pressing when the keyboard is in idle state Violated zones enables disables the display that indicates whether the system is ready for arming on the second line of the display In addition enabling this option you can see the detail of violated zones by pressing x when the keypad is in idle state Show warnings with PIN If this option is selected the first row of the keypad does not show the system status SYSTEM OK ALARM TAMPER etc until you enter a valid PIN aa In order to maintain compliance with the norms listed on page 73 the option Violated zones and the option Arming starus must be disabled In addition the option Show warnings with PIN must be enabled lares 2 1 programming manual 22 ACOUSTIC FEEDBACK Select which acoustic alerts you want to enable You can freely select the different options according to your needs EXIT TIME Select this option if you want to enable acoustic warning on the keypad during the exit time FIA In order to maintain compliance with the norms listed on page 73 this option must be enabled PREALARM Select this option if you want to enable acoustic warning on the keypad during the entry time FIG In ord
72. or Plants page Select the map where you want to place the camera symbol press the Ea Add button in the main menu Select Create a new symbol and then ONVIF Camera By pressing Search ONVIF devices button you can scan the network to detect ONVIF connected cameras after scan a list of detected cameras will be shown 6 Select the camera fill in the fields relating to the addresses as needed and press the Finish button ON bh WN NOTE Some camera models often require enabling ONVIF Protocol verify in the manual supplied by the manufacturer any activation procedure NETWORK TOPOLOGY AND ONVIF LIMITATIONS ONVIF Protocol is normally used to allow devices with heterogeneous uses to communicate each other Most commands provides for the interchange of information via UDP and HTTP POST packets ONVIF command structure was created to be compatible with Web Services and SOAP packaging standards XML over HTTP This peculiar structure allows devices to communicate each other but needs a good preparation of the network in order to function at its best After setting the graphic maps basis will retrieve all the information it needs from the camera to allow the web server to communicate with the device For this reason it is necessary at creation of your web server and graphic maps that the ONVIF camera and the PC running basis are connected in the same subnet and it is also necessary that the communication ports to the O
73. ord otherwise you will need to provide the required data to create a new account figure 12 Username Enter a user name with which you can sign in to your account Password Confirm Password Enter and confirm the password with which authenticate access Email Confirm Email Enter and confirm a valid e mail adaress Security Image Enter the numbers TIE seit hapara displayed in the box ae r Subscribe Newsletter Select or AA AA clear this option depending on your Sere on needs biti VA a accept the terms of Select this Sa i option after you have read the Acceptable Use Policy the Service Agreement and Privacy Policy f FT ASPE Tt a A E AE IN EEREN Create Account Press TO confirm and conclude the registration ee j el pa process Upon completion of the registration process the server will C Dyn mn gt send an email for confirmation and account activation ys T at the address previously posted figure 13 Follow the e js procedure given in the email and activate your account mbr NOTE EA AT The email sent from the server contains a link to access to complete your ab E account activation This procedure must be performed within 48 hours from placing their data on the server 4 Once you have activated your account and logged in return to the DNS section and select the Add Host Services option figure 14 43 lares programming manual 5 Select the ADD NEW DYNDNS HOSTNAME option among
74. programming manual Contact ID EVENT CODE 330 341 330 341 600 137 301 302 350 351 392 300 SIA EVENT CODE ET BR ES EJ ET ER ES EJ UX UX TA TR AT AR YT YR NT NR LT LR NT NR LB LX GG Peripheral number Peripheral number Timer number 00 00 00 00 00 00 00 CCC 000 000 000 000 000 000 000 000 66 KIND OF EVENT Controlled output tamper Controlled output tamper restore Fuse fault Fuse restore GPRS Remote Assistance enabled GPRS Remote Assistance disabled Failed supervision of IP Receiver Restore of supervision of IP receiver Battery charger fault Restore of battery charger Low output voltage Restore of low output voltage Radio noise on transceiver Restore of radio noise on transceiver 67 CATEGORY RECURRENCE Other events 1 lares Panel number of opis power supply stations Power supply Other events lares Panel number of opis power supply stations Power supply lares Panel number of opis power supply stations Number of duo Other events transceiver OCCURS WHEN Removes a EOL resistor on relay The thermal fuse enter in protection A remote assistance session via GPRS is enabled Failure of IP receiver supervision The power supply fails and fails to provide the necessary current
75. r each event you can program a maximum of 8 output activations maximum 8 power outputs maximum 8 switching outputs activate up to 2 timers activate the voice Communicator SMS or email or perform system arming rim ts ie ea lares programming manual DESCRIPTION OF PROGRAMMING PAGES The Window bar figure 3 contains buttons that allow you to enable the main Windows of the software To activate a window just click with your mouse on the corresponding button We ll explore the available windows in detail PARTITIONS On this page you can set the parameters for the partitions in the system To add a new partition just press the O Add button Let s see in detail each programmable field LABEL The label is the name associated with the partition This is used as a partition identifier in the programming pages as a string by mail or SMS dialer and automatic generation of voice messages Moreover this label is displayed in the event log logger AUTOMATIC MEMORY RESET By selecting this option when you disarm the partition any alarm memory will be automatically removed DELAYS SECTION ENTRY Time in seconds before the panel generates an alarm when violating a delayed input zone enabled on this partition FIA In order to maintain compliance with the norms listed on page 73 maximum input time should not exceed 45 sec EXIT Output time in seconds during which the zones programmed as delayed in output even if violated
76. rated web server can interface directly cameras that support the ONVIF standard enabling real time viewing of streaming video from camera directly onto the Web Server The ONVIF Open Network Video Interface Forum is a global forum which purpose is facilitating the development and use of a global standard for interfacing security systems based on IP or create a standard where IP devices that integrate surveillance functions can communicate each other ONVIF is an organization founded in 2008 by an agreement between Axis Communications Bosch Security Systems and Sony D l For more informations please visit NVI F www onvif org SYSTEM REQUIREMENTS Today ONVIF standard defines more or less forty commands To be sure that the camera is compatible with the Ksenia web server it must support at least the following ONVIF Core Specifications ONVIF Media Service Specifications e WS Probe e GetProfiles e WS Hello e GetSnapShotUri e GetCapabllities e GetDevicelnformations e GetNetworklnterfaces Check with the manufacturer that the camera supports the above commandas lares 38 programming manual 39 WEBSERVER CONFIGURATION Web Server configuration requires that camera and the running basis PC are in the same subnet Here below are described the operations sequence Connect the ONVIF camera and the PC runnig basis software to the same subnet Open the basis software create or open an account and select the Flo
77. s e Enabling the Enable DynDNS check fill the related fields to record the panel end point on GPRS at a server which provides the dynamic DNS service SCENARIOS PAGE e Group events by kind e Open the Other Events branch There are two new events Remote Assistance on GPRS Enabled Remote Assistance on GPRS Disabled These events can be programmed and as such you can bind to them SMS and or e mail sending Upon the Enabled event the body of the message or email contains the IP address obtained on GPRS channel In case you log the device on a DynDNS server it is not necessary to program the SMS except for confirmation OPERATION Remote Assistance operation consists of 5 logical blocks ENABLING OPENING SUPPORT SESSION BY THE USER This operation can be performed in several ways 1 Activation by SMS The SMS body should contain user code M m 1 no spaces between text characters Example 147258m1 2 Activation by Keypad Enter FIH 147255 Advanced Menu Remote Has Enable Continue User Main Menu it Advanced Menu ENTER ewer O O fe me ENTER YES ESC NO Upon completion will disolay the Remote Assistance status in the first row of the display 3 Enabling by Protocol For third party applications that want integrate themselves with lares Panels lares 54 programming manual 55 STARTS ACCEPTANCE BY THE INSTALLER ASSISTANT 1 Enter the Remote Assistance page e Selec
78. s valid only if you have programmed in three zones selecting it is sufficient that two out of three zones are violated in order to raise the alarm SEQUENTIAL If this option is selected zones must be violated in an exact sequence in order to generate the alarm first second and possibly third zone OUTPUTS On this page you can program the parameters relating to outputs To program an output press the O Add button or drag the corresponding icon from the Palette to the programming page Let s see in detail each programmable field Aside from the 1A relay with double Exchange all outputs are Open Collector transistorized 500 mA LABEL The label is the description that you want to give to the output will be used as identifier in other programming pages MODE MONOSTABLE Is an output that turns on for a programmed time ON time upon the occurrence of the event and then automatically return in stand by BISTABLE Is an output that follows the status of the corresponding event or can be triggered by an event and disabled by another POLARITY NORMALLY OPEN Select this option if you want the output in stand by mode when it s open and closes electrically grounded when it s closed negative to give NORMALLY CLOSED Select this option if you want the output in stand by mode when it s electrically closed to ground and active when it opens negative to send lares programming manual ANALOG Select this option i
79. seconds if you do not press any key Select this option if you don t want the automatic execution lares programming manual PARTITION MASK Assign the partitions on which the keypad can operate auxi EXPANSION MODULES auxi expansion modules can be added fo the system The number of programmable expansion modules depends on the Panel model To add an expansion module drag the corresponding icon from the palette to the page or select it by pressing the O Add button in the main menu Let s see its programmable parameters LABEL The label is the description that you want to give to the expansion module and will be Used as a label in other programming pages shown in the events log and used as a string for SMS or e mail alerts Each device on the BUS hence also the auxi expansion modules is identified by a serial number with 6 digits If this number is known we can add it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS M1 M5 TERMINALS ZONES OUTPUTS Programming logical zones or outputs to be assigned to the auxi terminals indicated with the name M1 M5 If a Terminal is assigned to a zone obviously it cannot be assigned output function pontis PSTN COMMUNICATOR A pontis PSTN Communicator can be added to the system To add a Commu
80. st be carried out strictly in accordance with the instructions described in this manual and in compliance with the local laws and bylaws in force These devices hare been designed and made with the highest standards of quality and performance adopted by Ksenia Security Is recommended that the installed system should be completely tested at least once a month Test procedures depends on the system configuration Ask to the installer for the procedures to be followed Ksenia Security srl shall not be responsible for damage arising from improper installation or maintenance by unauthorized personnel The content of this guide can change without prior notice from KSENIA SECURITY Information for users Disposal RAEE Directive Warning Do not use an ordinary dustbin to dispose of this equipment Used electrical and electronic equipment must be treated separately in accordance with the relative legislation which requires the proper treatment recovery and recycling of used electrical and electronic equipment Following the implementation of directives in member states private households within the EU may return their used electrical and electronic equipment to designated collection facilities free of charge Local retailers may also accept used products free of charge if a similar product is purchased from them If used electrical or electronic equipment has batteries or accumulators these must be disposed of separately according to local provisions
81. t the Remote Communication on GPRS option Once selected you can IAE enter the logical name or IP address received via mail or sms after programming and the listening port of Panel in Remote Assistance mode e Assoon as the panel you just added in the previous step appears in the devices table in Plug8Play mode check on devices is automatically done you can start a Remote Assistance session e Press on the Start Remote Session button to begin a session Upon receipt of the response message you will be able to interact with the Panel DATA EXCHANGE Data exchange between lares and basis software will take place as per protocol except for sending receiving information involving a delta of delay introduced by GPRS channel END OF ASSISTANCE SESSION BY THE INSTALLER ASSISTANT Pressing Stop Remote Session in Remote Assistance page you will terminate the current session NOTES During a remote assistance session by the installer you can do more than one Send page then more than a entry in programming The data configured during this session are actually updated on Panel only at the end of the current session With this option you can also modify the data configuration closely connected to Remote Assistance without losing control of the GPRS Panel interface If the Remote Assistance by Installer logoff message does not arrive at the Panel all data successfully sent will be updated only after the expiry of the time out of
82. the interval between two supervision packages ETHERNET SERVER PORT Port on which the panel will receive data from central station In the network it must be open in input ETHERNET CLIENT PORT Port used from the panel to send data to the central station It must be open in output If central station uses UDP most likey this value is the same of server port lares 46 programming manual 47 GPRS SERVER PORT Port on which the panel will receive data from central station on GPRS channel GPRS CLIENT PORT Port used from the panel to send data to the central station on GPRS channel If must be open in output If central station uses UDP most likely this value is the same of GPRS server port SUPERVISED RECEIVER Receiver to which the panel will send the supervision data OPTIONS WARNING ENABLEMENT Enable disable of single failure sources Disabling a failure source will permit normal panel operation even if the failure is present Es a IP panel with no ethernet connection should have Ethernet failure disabled GA In order to maintain conformity with norms listed on page 73 all faults must be enabled GENERAL OPTIONS MAINS FAULT DELAY Configure the delay time in minutes prior to raise the Power Supply fault event ALLOW WAEK PINs Selecting this option disables the robustness control of the pins which Panel makes to prevent the insertion of easily identifiable PINs e g date of birth etc UNBYPASS ZONES
83. the system All codes are 6 digits tor a total of 1 000 000 combinations LABEL The label is the name associated with the code This is used as the identifier in the code pages as a string from the SMS or email dialer and for automatic generation of voice messages Moreover this label is displayed in the event log logger GROUP Choose if desired the group associated with the code If you don t select any groups your code will always be active otherwise it will be active only when the associated group is active PARTITION MASK Assign the partition on which the code can run ENABLED If this option is selected the code Is active MASTER A master code can also handle the advanced menu on LCD keypad as well as modify PIN codes and qualifications that are not master too and that have the same partition mask PATROL If this option is selected the code will make disarming operations but the partition will automatically be rearmed at the end of the patrol time programmed in the Partitions page ARM ONLY If this option is selected the code will not perform disarming lares programming manual NO ACTION If this option is selected when the code is typed on the keypad is only activated the scenario that corresponds to the Recognized Code event without allowing to activate the scenarios associated with the keypad or enter the menu This option is very useful if you want to use code to do one action only example o
84. thout loosing the IDs Please note that IDs are NOT SAVED to the basis database by default so please NEVER use the SEND IDs key without using the LOAD IDs before VOICE MESSAGES In this page you can create record listen and delete your voice messages To add a new voice message oress the O Add button or drag the corresponding icon from the Palette Next you have to select the way to create the message importing the list from a wav file format or by registering them using the voice tab of your PC or finally generating them using the TTS engine text to speech In this case it is sufficient to write the text in the window and the software will automatically generate the corresponding voice message or generate them from descriptions labels inserted into various pages GENERATE MESSAGES FOR THE VOCAL GUIDE By pressing this button you can automatically generate all voice messages for the system lares programming manual GRAPHIC MAPS In this page you can customize the Panel web server by inserting maps placing buttons or icons on the maps themselves to put links to other web servers such as that of IP cameras For more details figure 8 please refer to the FAQ section of the website www kseniasecurity com NOTE After a Panel firmware update you might need to resend graphic maps using the Mk Send Page button 414 raphik Mapa rend PAS Lara e arte i p di Ci deine 6 Cnw SECTION lares Integ
85. thresholds customization e Partition Mask e Scoll of partition and ability to associate or not the zone to the selected partition e Chime e 24 Hours e Test e Command e Pulse number only values ranging from 1 to 7 are valid e Noise Immunity displayed only if the zone is Wireless PIR e PIR always active displayed only if the zone is Wireless PIR e Input delay e Immediate e Delayed e Output delay e Immediate e Delayed lares programming manual 60 61 Outputs Scroll the outputs e Description e Mode e Not used e Digital e Analogic e Polarity e Normally open e Normally closed e Kind e Monostable e Bistable e ON Time This menu is displayed only when you set output as Monostable The value is expressed in tenths of a second e Controlled This menu is enabled only for the the relay one in the mainboard BUS Peripherals Assign this menu shows the devices connected to the lares and not yet configured Each device is identified by its serial number Each device can be associated with a new device or a device already set by software e Scroll peripherals present on the BUS and not yet registered in the system e Scroll between the saved configurations that are compatible with the selected device Ability to assign the device to a configuration or register the device with the default configuration by selecting lt New Periph gt e Free This menu is enabled only for the the relay one in the mainboard
86. tion see following paragraphs ENABLE DYNDNS By selecting this option you can enable a server to handle dynamic DNS lares programming manual DYNAMIC DNS By selecting this option you can enable the dynamic DNS function INTRODUCTION The most known server which provides dynamic DNS service is dyn com so here we will refer to it but any other server can be used The dynamic DNS operation is shown in Figure 9 e DETECT IP CHANGE Make a check on your address by request to the appropriate server If your address has changed please update IP _ START e PERFORM UPDATE Send an update is to make a connection to a server that provides a dynamic DNS service and report your change of address To do this you must have registered at that site and you create a hostname to bind this address e PROCESS RETURN Do a check on the response obtained by the DDNS server e NOTIFY USER Report the user situation if required CONFIGURATION 1 Open the browser go right at www dyn com and go to the DNS section figure 10 pl DL J E a drun y a A AN p eiaa o raa EE Tel ia Ba Der pa a ra War la Ha Cure a C Dyn O e 2 Select Sign In option figure 11 E a j EL i E Pe rag u a its mgm E mia e aa EE Pol da Ba Dedo para a ra War li Ha Cerrar a Com Y an y pa ana z lares 42 programming manual 3 If you already have an account simply login by entering your Username and Passw
87. to each available color The LED of the selected color will be activated to confirm the configured operation PARTITION MASK Assign the partition on which the reader can operate gt divide BUS ISOLATOR REPEATER A divide BUS isolator repeater can be added to the system The number of programmable divide depends on Panel model To add a BUS isolator repeater drag the corresponding icon from the palette to the page or select it by pressing the Add button in the main menu Let s see its programmable parameters LABEL The label is the description that you want to give to the BUS isolator repeater and will be Used as a label in other programming pages shown in the events log and used as a string for SMS or e mail alerts Each device on the BUS hence also the divide BUS Isolator Repeater is identified by a serial number with 6 digits If this number is known we can insert it in Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programmation a serial number of a device connected to the KS BUS opis SUPERVISED POWER SUPPLY STATION opis Supervised Power Supply Stations can be added to the system The number of programmable stations depends on Panel model To add a supervised power supply station drag the corresponding icon from the palette to the page or select it by pressing the O Add button in the main menu
88. to the system The output voltage of power supply drops below the threshold Radio noise detected at 868MHz ENDS WHEN Restore of EOL resistor on relay Restore of thermal fuse A remote assistance session via GPRS is disabled The IP receiver responds to the supervision packets The fault is restored The output voltage of power supply comes back over the threshold End of radio noise at 868MHz lares programming manual Contact ID EVENT CODE 324 300 410 356 300 312 137 SIA EVENT CODE YA YH yI YJ RB RS YS YK 1P YQ YP YQ XQ XH GG 00 00 00 00 CCC 000 000 000 000 KIND OF EVENT First analogic level Second analogic level Third analogic level Fourth analogic level Fifth analogic level Partition alarm Partition tamper Negligence on partition Missed arming O Key on keypad X 1 Key on keypad X 2 Key on keypad X 3 Key on keypad X 4 Key on keypad X 5 Key on keypad X 6 Key on keypad X 7 Key on keypad X 8 Key on keypad X 9 Key on keypad X Green LED on reader X Red LED on reader X White LED on reader X Blue LED on reader X Yellow LED on reader X Timer of Scheduler SUMMARY TABLE OF SPOT EVENTS events that have a start only CATEGORY RECURRENCE Zone events Numero analogic zones Analogic levels Number of
89. tput must be bistable type e The output shouldn t have the Remote Control option enabled e The output shouldn t be handled as a toggle on no other scenario e The output shouldn t be associated with spot type events If one ot these condition is not true the output will be activated for any of its programmed events but be will deactivated for any of the programmed events lares programming manual TIMERS Select the timers Up to 2 to start stop for the event For each of them select the start RED dot or stop GREEN dot clicking the button at right of selection DESTINATIONS Select the destinations up to 8 of messages to be sent from the panel The kind of message depends on the programmed attributes in the phonebook page For example if we associate to contact an email address upon the occurrence of the event will automatically be sent the email and so on In the case of reports with SIA DC 09 Protocol select the IP receiver The panel will manage automatically the backup receivers so just put one IP receviver here MESSAGES For voice call select the messages to send for the event in these 4 fileds CODE Contact ID and SIA event code ARMING MODE Select partition arming mode that should be activated from the event RESET MEMORY Check this box if the event should clear the alarm memories CLEAR CALL QUEUE Check this box if the event should clear the communication queue i e for disarming events RESET ALARMS Ch
90. utput activation to open a door LOAD PINs By pressing this button you can load PIN from the Panel and save them on the software database This action in conjunction with the SEND PINs button will allow you to clear or replace the panel without loosing the PINs Please note that PINs are NOT SAVED to the basis database by default so please NEVER use the SEND PINs key without using the LOAD PINs before TAGS In this page you can add your Tags to be used on ergo LCD keypads or on volo proximity readers Here the tags are just enabled theirs acquisition will then be performed by keypad programming menu To add a Tag press the O Add button or drag the corresponding icon from the Palette All Tags have a 4 byte code for a total of 4 294 967 296 combinations LABEL The label is the name associated with the Tag This is used as the Tags identifier on programming pages as a string by mail or SMS dialer and automatic generation of voice messages Moreover this label is displayed in the event log logger GROUP Choose the group associated with the Tag If you don t select any groups the Tag is always on otherwise it will be active only when the associated group Is active CHANGE PARTITION MASK Assign the partition on which the Tag can operate INSTALLER It is a Tag that allows access to the Installer menu using a code valid for a limited period of time by an hour ENABLED If this option is selected the
91. vides the dynamic DNS service to update the IP address The dynDNS service is also supported by most routers By adjusting the parameters for the DNS service on your router you can achieve the same result lares programming manual ENABLE NTP CLIENT NETWORK TIME PROTOCOL By selecting this option you can enable the date and time synchronization service from a NTP server NTP SETTINGS NTP SERVER HOST NAME Select a server among those proposed TIME ZONE OFFSET Value in hours of time zone set SEND WEB SERVER Enable the web server function in the panel You can choose EXTENDED tabular format that allows a quick check up of the system status and the remote management and control of the system COMPACT graphic format that allows you to control and remotely manage the system ADVANCED ETHERNET PARAMETERS In this section you can modify the programming ports it is recommended that you contact your network administrator for setting these parameters before connecting the Panel on the network in order to avoid conflicts and other equipment malfunctions IP EVENTS Here you can program the panel to send communication through ethernet using the SIA DC 09 protocol ENABLE EVENTS OVER IP Enables the panel to send periodic supervision messages to the IP receiver ENABLE CHANNEL SUPERVISION Enables the panel to send periodic supervision messages to the IP receiver SUPERVISION INTERVAL Time in seconds programmed to configure
92. volo Proximity Readers Scoll the volo e Partition Mask e Scroll the partitions and ability to enable the reader to the selected partition e LEDs and scenarios e Green LED e Red LED e White LED e Blue LED e Yellow LED e volo options e LED at disarmed system e Display of System status lares programming manual 62 63 Wireless Enroll Free Delete Codes management New code Code options Delete code e lt New Periph gt e Enrolling e lt Custom programmation gt e Disconnecting wireless devices from the lares panel without loosing their programming data e Remove wireless devices from lares programming e Scrolling between the empty positions on which you can save the new code e Enter PIN e Scroll the valid codes e Description e Change PIN e Partition mask e Scrolling between the different partitions and ability to enable or disable the code for the selected partition e Enable e Main code e Patrol e Arming only e Remove an existing code lares programming manual Tags management Save Tag e Enroll a new RFID tag in the system Assign Tag e Assign a RFID tag to a previous programmed tag position Tag options e Modify RFID tag parameters Delete Tag e Remove a previously programmed RFID tag Tag options e Description e Installer e Enable e Patrol e Arming only e Partition mask e Enable disable RFID tag on partitions Scenarios Arming mode e Assign
93. which the virtual keypad will operate 4 Basically in our system we could have more physical zones intended as terminals than logical areas which in the case of lares 128 IP are 128 as there may be unused physical areas 5 If a terminal is assigned to a zone obviously cannot be assigned output function lares programming manual BUS PERIPHERALS gemino GSM COMMUNICATOR A gemino BUS Communicator can be added to the system To add a gemino drag the corresponding icon from the Palette to the programming page or select it by pressing the O Add button in the main menu Let s see ifs programmable parameters LABEL The label is the description that you want to give to the communicator and will be Used as a label in other programming pages shown in the events log and used as a string for SMS or e mail alerts Each device on the BUS hence also the gemino GSM communicator is identified by a serial number with 6 digits If this number is known we can add it in the Serial number field If this number is not known you can check on Assign serial number from keypad and then from the ergo installer menu you can assign to this programming a serial number of a device connected to the KS BUS ENABLE SIM 2 Select this option if there are two SIM cards installed on gemino ENABLE EXTERNAL ANTENNA Select this option if an external antenna is wired on gemino DISABLE INTERNAL ANTENNA This option is meaningful only if
94. will not generate any alarm WARNING Time in minutes before the system is armed according to the scheduler during which the imminent arming is reported by beeps on keypads TG In order to maintain compliance with the norms listed on page 73 this option should remain selected PATROL Time in minutes starting from a disarm of the system with patrol attribute with a code key When this time expires the partitions will be automatically armed back NEGLIGENCY Time in hours starting from partition disarming If the partition is not armed when the time expires it generates the Partition Negligence event that can be associated with actions e g could be programmed to 24h to manage any error or arming omission and thus allow the panel to automatically arm CYCLE Time in minutes that determines the maximum duration of the alarm cycle During the alarm condition lares does not generates further alarms in partition and eventually generates an alarm event for each zone in partition This avoids the queue of numerous phone calls or reports lares programming manual 10 LINKED EVENTS SECTION This section provides a list of events related to the selected partition Selecting one or more events you can program the actions from the Details window The planned actions will be executed upon the occurrence of the event Refer to the paragraph Scenarios for programming details ARMING MODES In this page it is possible to program t
95. y Other events RECURRENCE Number of BUS Peripherals Number of BUS Peripherals Number of Wireless Peripherals Number of Wireless repeaters Number of generic timers lares Panel number of duo wireless receivers number of opis power supply stations lares Panel number of imago sirens number of radius sirens number of duo wireless repeaters number of opis power supply stations OCCURS WHEN A peripheral disappears from the BUS The peripheral is open A wireless peripheral disappears The peripheral is open The Timer starts The Panel cover is open Missing power supply on lares on duo wireless receiver or on opis power supply station The battery voltage drops below the threshold when missing net The Ethernet cable is disconnected The pontis telephone line is cutted Missing GSM net on gemino Enter the programmation with installer code lares ENDS WHEN The peripheral comes back to work properly The peripheral is closed again The wireless peripheral comes back to work properly The peripheral is closed again The Timer expires The Panel cover is closed Restore of power supply on lares on duo wireless receiver or on opis power supply station The 220V net comes back The Ethernet cable is connected The pontis telephone line is restored The GSM net on gemino is restored Exit from programmation