Home
PM63 PowerVac+ Intermittent Aspirator User Manual
Contents
1. POWER VAC ASPIRATOR Model No PM63 shown PM63E Outlet ix REY J SAVE THESE INSTRUCTIONS ACAUTION Federal USA law restricts this device to sale by or on the order of a physician PRECISION MEDICAL 300 Held Drive Tel 001 610 262 6090 Northampton PA 18067 USA Fax 001 610 262 6080 www precisionmedical com CONTENTS RECEIVING 2 INTENDED a ee re Tent Vee 2 READ ALL INSTRUCTIONS BEFORE USING 2 EXPLANATION OF ABBREVIATION 2 SAFETY INFORMATION WARNINGS AND CAUTIONS 2 SPECIFICATIONS E E 4 COMPONENT DESCRIPTION 5 GROUNDING INSTRUCTIONS 6 OPERATING INSTRUG TIONS ws cece 6 CLEANING MAINTENANCE 7 PIN 8 DISPOSAL 8 REPLACEMENT PARTS srisccseccccsccssscatecsssarcceasesesessacescatecearecnoeseete 9 LIMITED WARRANTY 0cccccccseecceeseceeeeececeseeeeseeeceeanseeeeeeneess 10 POWER VAC RECEIVING INSPECTION Remove the Precision Medical Inc Power Vac Aspirator from the packaging and inspect for damage If there is any damage DO NOT USE and contact
2. lost sales or injury to person or property Correction of non conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical Inc whether based on contract negligence strict tort or otherwise Precision Medical Inc reserves the rightto discontinue manufacture of any product or change product materials designs or specifications without notice Precision Medical Inc reserves the right to correct clerical or typographical errors without penalty 595 lt lt gt ZS 2S 23 gt ZS 00 506 a 559 PRECISION MEDICAL Precision Medical Inc 300 Held Drive Northampton PA 18067 USA Toll Free Tel 800 272 7285 Toll Free Fax 800 352 1240 Tel 001 610 262 6090 Fax 001 610 262 6080 ISO 13485 Certified Tell us how we are doing Visit us at www precisionmedical com 502604 Rev8 11 18 11 Printep in USA
3. Remove the canister from its bracket and empty as instructed by your Physician or Healthcare Professional e Replace Suction Canister and reconnect all suctioning tubing CAUTION Canister is for single patient use only CLEANING MAINTENANCE AWARNING Turn the Power Vac Aspirator off and disconnect from power source before cleaning DO NOT attempt to repair There are no serviceable parts inside The Inline Hydrophobic Filter cannot be cleaned If it becomes contaminated or clogged it must be replaced To replace Inline Hydrophobic Filter 1 Disconnect filter assembly from Suction Canister and remove Suction Canister from the Aspirator 2 Remove filter assembly from the Aspirator 3 Dispose of filter only 4 Install new Inline Hydrophobic Filter Part 1690 and reconnect tubing and elbow Tubing is single patient use only DO NOT clean POWER To replace Air Filters CAUTION e Excessive dust build up on air filters will reduce performance of Aspirator If this occurs filters should be cleaned or replaced e DO NOT use where saline mist could be drawn into the Aspirator The Air Filters do not filter out saline Saline causes rapid deterioration of the Aspirator and will void the warranty 1 Check both Air Filters on top rear of cabinet for dust build up 2 If dust build up occurs unplug Aspirator remove Air Filters from their recessed areas and wash in warm s
4. are in the OFF position 3 Ensure the Inline Hydrophobic Filter is properly connected to the vacuum port on Suction Canister lid The Inline Hydrophobic Filter prevents liquid from entering the vacuum pump CAUTION DO NOT run the Aspirator without Inline Hydrophobic Filter and canister This will void the warranty 4 Plug the Aspirator into a properly grounded receptacle 5 Press the On Off Switch to the ON position 6 Turn the Selector Knob to the REG position POWER VAC 7 Block the patient connection on the Suction Canister and adjust the Vacuum Control Knob to the desired vacuum To INCREASE vacuum Turn knob CLOCKWISE To DECREASE vacuum Turn knob COUNTERCLOCKWISE e Vacuum should be set as prescribed by your physician or healthcare professional NOTE Intermittent cycle starts in the OFF phase therefore a delay occurs before the ON suction cycle begins 8 Turn Selector Knob to the INT position to obtain an intermittent adjustable vacuum that cycles on and off 9 Connect one end of Patient Suction Tubing to the port on the Canister marked Patient Tubing 10 Connect other end of Patient Suction Tubing to suction catheter and begin procedure as instructed by healthcare provider 11 When procedure is completed press the On Off Switch to the OFF position DO NOT overfill the canister 12 Empty the Suction Canister as follows e Disconnect all suctioning tubing e
5. your Provider INTENDED USE To supply a continuous or intermittent vacuum source adequate within the stated operating vacuum range to aspirate fluids in medical suctioning procedures by trained healthcare professionals READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to operate the Power Vac Aspirator This is provided for your safety and to prevent damage to the Aspirator If you do not understand this manual DO NOT USE the Aspirator and contact your Provider EXPLANATION OF ABBREVIATION mmHg Millimeters of Mercury SAFETY INFORMATION WARNINGS AND CAUTIONS Indicates an imminently hazardous situation which if not avoided will result in death or serious injury AWARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury ACAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury AUTION Used without the safety alert symbol indicates a CASE potentially hazardous situation which if not avoided may result in property damage CONSULT ACCOMPANYING DOCUMENTS Protective Earth Ground Fuse ft Type B Equipment E Alternating Current POWER VAC ADANGER TO REDUCE THE RISK OF ELECTROCUTION Always unplug Power Vac Aspirator immediately after using DO NOT use while bathing DO NOT place or store Aspirator w
6. 02687 Suction Canister 2 000 cc with lid 502690 Inline Hydrophobic Filter amp Tube Assy 503240 Fuse TROUBLESHOOTING If the Power Vac Aspirator fails to function consult the Troubleshooting Guide below If problem cannot be solved consult your Provider Problem Probable Cause Remedy Aspirator will not operate 1 On Off switch in OFF position Power Cord not connected properly Thermal limit exceeded Blown Fuse k 2 Push On Off switch to ON position Check plug at outlet Shut Aspirator OFF wait 15 minutes be sure vents are clear Replace Fuse No vacuum on gauge no vacuum at Patient Connection Tubing 2 Hydrophobic Filter assembly not connected properly Suction Canister not connected or assembled properly Defective Suction Canister Defective regulator 2 3 4 Confirm and tighten connections Confirm and tighten connections assembly Replace Suction Canister Contact your Provider No Vacuum on gauge vacuum at Patient Tubing Connection Defective vacuum gauge Contact your Provider Vacuum on gauge No vacuum at Patient Tubing 1 2 Clogged Hydrophobic Filter Canister overfilled _ 2 Replace Hydrophobic Filter Empty canister Unable to adjust vacuum Defective regulator Contact your Provider P
7. OWER VAC LIMITED WARRANTY AND LIMITATION OF LIABILITY Precision Medical Inc warrants that Power Vac Aspirator the Product will be free of defects in workmanship and or material for the following period Three 3 years from shipment Should any failure to conform to this warranty appear within the ap plicable period Precision Medical Inc shall upon written notification thereof and substantiation that the goods have been stored installed maintained and operated in accordance with Precision Medical Inc s instructions and standard industry practice and that no modifications substitutions or alterations have been made to the goods correct such defect by suitable repair or replacement at its own expense ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES The representatives of Precision Medical Inc or any retailers are not authorized to make oral warranties about the merchandise described in this contract and any such statements shall not be relied upon and are not part of the contract for sale Thus this writing is a final complete and exclusive statement of the terms of that contract THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY FITNESS FORA PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY WHETHER EXPRESS ORIMPLIED Precision Medical Inc shall not under any circumstances be liable for special incidental or consequential damages including but not limited to lost profits
8. here it can fall or be pulled into a tub or sink DO NOT place or drop into water or other liquid DO NOT reach for the Aspirator that has fallen into water Unplug immediately DO NOT attempt to repair Aspirator Any attempt could result in electrical shock DO NOT allow the aspirator to exceed Operating or Storage Temperature specifications Never use near any type of flame or flammable explosive substances Caution must be exercised when using this Aspirator where oxygen is being administered AWARNING TO REDUCE RISK OF BURNS ELECTROCUTION FIRE OR INJURY TO PERSONS The Power Vac Aspirator should never be left unattended when running Close supervision is necessary when the Aspirator is used by on or near children or invalids Use the Aspirator only for its Intended Use as described in this manual Adjust to desired setting prior to use DO NOT use attachments not recommended by Precision Medical Inc DO NOT use if Aspirator has a damaged cord or plug DO NOT use if Aspirator has been dropped or damaged DO NOT cover air vents Restriction of air flow will cause unit to overheat causing the thermal reset to shut down the Aspirator DO NOT drop or insert any object into any opening or hole Connect this Aspirator to a properly grounded outlet only See GROUNDING INSTRUCTIONS Keep the cord away from heated surfaces POWER VAC SPECIFICATIONS Operating Vacuum Ra
9. itrous oxide Specifications are subject to change without prior notice POWER VAC COMPONENT DESCRIPTION ACAUTION Missing or illegible labels must be replaced contact Precision Medical Inc Suction Canister Knob Hydrophobic Filter Vacuum Control Knob Air Inlet Filters AC Inlet Fuse Holder Power Cord Hour Retainer Meter POWER VAC GROUNDING INSTRUCTIONS The Power Vac Aspirator must be plugged into an electrical outlet that is properly grounded In the event of an electrical short circuit grounding reduces the risk of electrical shock This product is equipped with a grounding circuit ADANGER Improper use of the grounding plug can result in a risk of electrical shock AWARNING Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked Hospital Grade OPERATING INSTRUCTIONS AWARNING e Read this User Manual before operating the Power Vac Aspirator Full Vacuum is present between settings CAUTION Inspect the Power Vac Aspirator for visual damage before use DO NOT USE if damaged 1 Place Aspirator near a properly grounded electrical receptacle on a table floor or other horizontal smooth hard surface Allow a minimum of 4 in 10 cm clearance on all sides to ensure adequate air flow for cooling of Aspirator 2 Ensure the On Off Switch and Selector Knob
10. nge 0 200 mmHg with Full Vacuum Full Vacuum is 330 2 mmHg 51 mmHg Vacuum Modes REG Regulated provides an adjustable continuous vacuum level OFF No Vacuum INT Intermittent provides an adjustable intermittent vacuum level Intermittent Cycle Time Factory set at approximately sixteen 16 seconds ON eight 8 seconds OFF Gauge Accuracy 0 100 mmHg 4 mmHg 101 200 mmHg 6 mmHg Dimensions Length 15 9 in 40 3 cm Width 7 4 18 7 cm Height 10 1 in 25 7 cm Weight 21 2 Ibs 9 6 kg Shipping Weight 24 5lbs 11 1 kg Electrical PM63 108 132 VAC 60 Hz 5 Amps PM63E 207 253 VAC 50 Hz 2 2 Amps Operating Temperature Range 50 F to 104 F 10 C to 40 C Transport Storage Requirements Temperature Range 4 F to 104 F 20 C to 40 C Humidity Max 95 Noncondensing Filter Inline Hydrophobic Safety Systems High Temperature Motor Shutdown Class B Thermal Limit Automatic Reset Suction Canister Maximum Volume 2 000 cc Do not exceed vacuum level of 25 inHg 640 mmHg Equipment Classification Class with respect to protection from electrical shock Type B degree of protection against electrical shock IPXO degree of protection against ingress of liquids Mode of Operation continuous This Power Vac Aspirator meets the EMC requirements of EN55011 This Power Vac Aspirator is not suitable for use in the presence of a flammable anesthetic mixture with air oxygen or n
11. oapy water and rinse 3 Absorb excess water from filters with a dry towel 4 Return filters to their original locations Cleaning for Exterior Components Use a cloth or sponge dampened with soap and water Wipe dry with a clean cloth or paper towel AWARNING e DO NOT immerse the Power Vac Aspirator in liquid If Aspirator is used for treatment of infectious disease consult your Physician or Healthcare Professional for recommended cleaning procedures RETURNS Returned products require a Returned Goods Authorization RGA number contact Precision Medical Inc All returns must be packagedin sealed containers to prevent damage Precision Medical Inc will not be responsible for goods damaged in transit Refer to Precision Medical Inc Return Policy available on the Internet www precisionmedical com Manuals available on our Website www precisionmedical com NOTE When returning the Power Vac Aspirator disconnect the power cord from the back of unit DISPOSAL INSTRUCTIONS Dispose of the Power Vac Aspirator in accordance with the local regulations Please Recycle eo AWARNING Product should be cleaned before being disposed of Potential for Biohazard POWER VAC REPLACEMENT PARTS Part Description 1690 Inline Hydrophobic Filter 1955 Suction Tubing 1 4 ID x 6 ft Clear Non Conductive PVC 502391 Small Air Filter 502471 Large Air Filter 5