1. button 2 Tap the Demonstration button to select it A screen advising you are in simulation mode displays select Continue NOTE The demonstration takes you through a simulated vehicle identification process simply accept the default data as it displays on the screen to continue 3 Follow the on screen instructions and select as needed until the Systems menu displays Previous Vehicles amp Data The Previous Vehicles amp Data button allows you to quickly configure the scan tool to the identity of a recently tested vehicle and to access saved data files A menu with three options opens when this button is selected e Vehicle History opens a list you can use to recall the identification information of previously tested vehicles e View Saved Data opens a list of all the data movies and screen images that are stored in scan tool memory e Delete Saved Data allows you to permanently erase saved files from scan tool memory 4 Select OK on the confirmation screen to load the selected database 5 Select OK from the Demo mode message screen A systems menu which shows all of the systems available for testing displays 6 Select from any of the systems listed then select from the submenus IMPORTANT Do not connect a vehicle to the scan tool while in the Demonstration mode Printing and Storing Saved Data The SOLUS Ultra does not directly interface with a printer Instead the scan tool conne
2. button on the left side of the toolbar Allows you to select which parameters to display from the list This button displays when viewing a data list Switches between PID List and Graph display modes This button displays when viewing a data list Locks or unlocks the highlighted parameter This button displays when viewing a data list Saves the current datastream information to tool memory Opens the tools menu which allows you to adjust basic tool settings Indicates live data from the vehicle is being displayed Indicates the data being displayed is paused when reviewing a movie which displays a menu of available tests or data from the vehicle A vertical scroll bar appears when there is additional data either above or below what 5 Power Button switches the unit on and off he 2 AP 3 Previous Moves back one frame when viewing To install the battery pack 3 b 1 Loosen the two captive screws that secure ies To connect the AC DC power supply N b 1 Attach the power cord to the AC DC power supply Figure 2 2 Controls BASIC STEPS To begin operating your SOLUS Ultra scan tool 1 Install the battery pack 2 04650A into the SOLUS Ultra unit EESC318 2 Connect the AC DC power supply to the SOLUS Ultra unit to charge the battery pack 3 Power on the scan tool Battery Pack Installation Use the following procedure to install the battery pack the battery cover to the back
3. The Scanner button opens a list of available vehicle manufacturers and begin the process of identifying the vehicle to be tested Because the scan tool presents data provided by the ECM of the vehicle being tested certain attributes of the test vehicle must be entered into the scan tool to ensure the data displays correctly The vehicle identification sequence is menu driven simply follow the screen prompts and make a Series of choices Each selection advances you to the next screen Exact procedures may vary somewhat by the make model and year of the test vehicle A confirmation screen displays once all of the identification information has been entered Select OK at the confirmation screen to continue The database for the identified vehicle loads and a list of systems available for testing displays The Tools button allows you to adjust tool settings to your personal preferences access scan tool system information and perform other special Operations Selecting Tools opens a menu of options e Connect To PC use to transfer and share files with a personal computer PC e Configure Shortcut Key use to change the functionality of the 4 shortcut key e System Information use to display configuration information for your scan tool e Settings use to configure certain characteristics of the scan tool e Configure Units use to choose between Imperial or metric units of measure Selecting a menu item eit
4. above 104 F 40 C which disables charging Allow the unit to cool down and make sure the ventilation ports are not obstructed if the LED is amber 3 Mini USB Client Port use for connecting the scan tool to a personal computer 4 Micro secure digital uSD Card Port holds the uSD card IMPORTANT The micro SD card MUST be installed for the that contains the operating system programming scan tool to operate Do not remove the micro SD card 5 Data Cable Port use for connecting the scan tool to a test while the unit is powered on vehicle Figure 2 1 Connections Controls The external controls on the SOLUS Ultra are simplified since most operations are controlled through the touch screen Touch screen navigation is menu driven which allows you to quickly locate the needed test procedure or data through a series of choices and questions 1 N x Button exits a menu or program returns to the previous screen or answers no to a question on the screen 2 Y Button selects a menu or program advances to the next screen or answers yes to a question on the screen 3 Directional Buttons moves the highlight on the display screen up A down V left lt 4 and right as indicated by the arrows 4 Shortcut Button can be programmed to provide a shortcut for performing a variety of routine tasks NAVIGATION Scan tool screens typically include three sections e Title bar shows test a
5. cts to your personal computer PC through the USB port see Tools amp Setup Once connected to the PC SOLUS Ultra files can be printed transferred and copied using ShopStream Connect ShopStream Connect is a free software application download available at http www1 snapon com diagnostics uk eton s a N Mber a OSON CO E ee Scanner Cable Assembly romanon wooro OOOO Snap on reserves the right to make changes at any time without notice SOLUS ULTRA KIT CONTENTS IMPORTANT Be sure to read all of the safety messages in the Important Safety Instructions provided before operating this product Remove all of the SOLUS Ultra components from the packaging and verify the contents Table 6 1 SOLUS Ultra kit contents Trademarks Snap on SOLUS Ultra and Scanner are trademarks of Snap on Incorporated All other marks are trademarks or registered trademarks of their respective holders IMPORTANT Before operating or maintaining this unit please read the manual carefully paying extra attention to the safety warnings and precautions Copyright Information 2011 Snap on Incorporated All rights reserved z Visit our websites at Disclaimer of Warranties and Limitation of Liabilities http www1 snapon com diagnostics uk United Kingdom The information specifications and illustrations in this quick start guide are based on the latest information available at the time of printing While the authors have take
6. her opens a submenu of additional choices or a dialog box that includes instructions Choose from the menus and follow the Screen prompts to configure your SOLUS Ultra to your preferences OBD IT EOBD The OBD II EOBD button opens a menu that allows you to perform generic OBD II EOBD system tests without first identifying a specific vehicle The OBD II EOBD menu includes e OBD Health Check e OBD Diagnose OBD Health Check offers a way to quickly check for and clear generic diagnostic trouble codes DTCs and to check readiness monitors Selecting opens a submenu of options choose from the submenu and follow the screen prompts OBD Diagnose opens a menu with the following options e Start Communication begins the test session e Select Communication Protocol allows you to select which communication protocol to use e Connector Information provides data link connector DLC location details for most models Demonstration Program Your SOLUS Ultra includes a demonstration program that allows you to become familiar with many of the capabilities of the scan tool without actually connecting to a vehicle Sample data and mock test results help you quickly learn how to navigate the menus and perform basic operations To start the demonstration program 1 From the Home screen tap Scanner The manufacturer menu which lists all of the makes available for testing displays The list also includes a Demonstration
7. n due care in the preparation of this manual nothing contained herein A SOLUS ULTRA QUICK START GUIDE For Technical Assistance Call CALL 44 0 845 601 4736 United Kingdom e Modifies or alters in any way the standard terms and conditions of the purchase lease or rental E mail DiagnosticsUKproductsupport snapon com United Kingdom agreement under the terms of which the equipment to which this manual relates was acquired e Increases in any way the liability to the customer or to third parties 2011 Snap on Incorporated All rights reserved Snap on is a trademark of Snap on Incorporated All other marks are trademarks or registered trademarks of their respective holders Pictures are for illustration purposes only Specifications subject to change without notice EAZ0075L20A Rev B http www1 snapon com diagnostics uk FAZ0075L20A Rev B CONNECTIONS AND CONTROLS Connections All of the ports for connecting the SOLUS Ultra to a vehicle personal computer or power source are located on the top panel of the unit 1 DC Power Supply Input Port use for connecting the AC DC power supply 2 Battery Status Indicator a multi colour light emitting diode LED that illuminates to indicate battery status interpret as follows Green indicates the battery is fully charged Red indicates the battery is being charged Amber indicates a battery issue This is usually caused by excessive battery temperature
8. nd tool status e Toolbar contains test controls e Main body displays menus and test data Title Bar The title bar at the top of the screen provides information about current tool operating conditions Title bar options vary depending upon vehicle make and model what test is being performed or what menu is selected Custom Depending upon what is being displayed in the main body of the screen either the vehicle ID or the active menu is shown at the left side of the title bar An icon at the far right side of the title bar indicates whether the tool is being powered by the internal battery pack the test vehicle or the AC DC power supply A communication icon displays to the left of the power source indicator whenever the scan tool is actively communicating with a test vehicle or a personal computer Toolbar The toolbar located under the title bar contains a number of selectable buttons that control tool functions What buttons appear on the toolbar varies as only buttons that are active or available for the current screen and test mode display A brief description of common toolbar button operations are shown in the table that follows A a 1 Main Body The main body is the lower portion of the screen Data List Lock Unlock Pause Returns to the previously viewed screen This button is always at the left hand edge of the toolbar Returns to the Home screen This button is always alongside the Back
9. nnecting e Confirmations e Warnings e Errors Loading and Connecting Messages Loading and connecting messages display when the scan tool is performing an internal operation The Home screen opens when SOLUS Ultra is powered on Touch sensitive buttons on the Home screen are used to select from the four primary functions of the scan tool is currently shown on the screen The main body is the lower portion of the screen which displays a menu of available tests or data from the vehicle A vertical scroll bar appears when there is Y additional data either above or below what is currently BEWE Next Frame PID Triggering such as loading a database initiating a test or establishing communications with the vehicle The message automatically clears once the internal operation is complete Confirmation Messages Confirmation messages display when the action you are about to perform cannot be reversed or when the selected action requires an acknowledgment to continue e Scanner e OBD II EOBD e Previous Vehicles amp Data e Tools recorded or paused data Moves forward one frame when viewing recorded or paused data Opens a menu that allows you to set arm and clear threshold values to automatically begin recording data Increases and decreases the scale of the data graphs When a response is not required the message displays briefly then disappears Warning Messages Warning messages inform that com
10. of the unit Lift to open the battery cover Position the new battery pack and slide it into its seated position in the battery compartment 4 Make sure the battery pack is fully seated Fit the battery cover 6 Tighten the two captive screws W N 1 Captive Screws 2 Battery Cover Figure 3 1 Battery pack Vi Powering on the SOLUS Ultra The SOLUS Ultra unit will be switched on when the AC DC power supply is connected there is no need to wait for the battery pack to be charged Press the power button on the face of the unit to switch the SOLUS Ultra unit on the scan tool initialises and opens to the Home screen Power Supply Connection Use the following procedure to connect the power supply 2 Plug the power cord into a service outlet 3 Fit power supply cable jack into the DC port marked 10 30V on the top of the SOLUS Ultra unit An LED alongside the DC port illuminates to indicate power is being supplied Once the scan tool is powered on an icon in the upper right corner of the display screen indicates the battery state of charge refer to the SOLUS Ultra User Manual for details Figure 3 2 Power Button 1 Go to beginning 2 Go up 1 page 3 Slider position indicator 4 Go down 1 page 5 Go to end J shown on the screen Figure 4 1 Sample scroll bar Screen Messages Four types of on screen messages may display while operating the scan tool e Loading and co
11. pleting the selected action may result in an irreversible change or loss of data Error Messages Error messages display when a system or procedural error such as a cable disconnection or loss of signal occurs OPERATIONS