Home
CB36M600X Installation, Use & Care Manual 2015
Contents
1. kk Supply cable type SJT 3x16AVWVG with 2 poles earth fused U S Plug lenght 1 5m Black line L White neutral W pecan ree NL Green earth E L E SPARKS LEGENDA COLOR WIRES G GREEN EARTH B BLACK LINE W WHITE NEUTRAL GAS CONNECTION All gas connections must be made according to national and local codes This gas supply service line must be the same size or greater than the inlet line of the appliance This range uses a 1 2 NPT see fig in this chapter for details of gas connections installations inlet Sealant on ali pipe joints must be resistive to LP gas 1 Manual Shut off Valve This installer supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and in a position where it can be reached quickly in the event of an emergency The manual shut off valve shall be installed properly in order to be accessible when appliance is installed in definitive position In Massachusetts A T handle type manual gas valve must be installed in the gas supply line to this appliance 2 Pressure Regulator see fig in this chapter a All cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since service pressure may fluctuate with local demand The pressure regulator is supplied separately with the appliance regulator has two female threads 12 NPT it shall be installed properly in order to be accessible when appliance is insta
2. knob to the MINIMUM position small flame 2 Remove the knob of the valve that is press fit on the rod of that valve 3 The cooker is equipped with safety valves use a small slotted screwdriver the choke valve located on the valve body and turn the choke screw to the right or left until the burner flame is adjusted to minimum 4 Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position WARNING The above mentioned adjustment should be made only for natural gas while for operation with liquid gas the screw must be locked at the end in a clockwise direction The grill burner always operates at maximum and therefore no minimum adjustment is required SERVICE amp MAINTENANCE INSTRUCTIONS Service and maintenance only to be carried out by an authorised person To replace parts such as burners valves and electric components the appliance must be open removing the worktop Note if the valves must be replaced first disassemble the ignitions switches wires It is recommended to replace the valve gaskets each time the valve is replaced thus ensuring a perfect seal between the body and the gas train WARNING After first installation of the appliance or after any service intervention concerning main gas parts of the appliance make the leak test using water with soap on the gas connections in order to verify the correct installation Do not use fire for gas leak testing USER MANUAL DESCR
3. 4 w c 1 00 kPa for Natural Gas and 11 w c 2 75 kPa for LP Gas ATTENTION A manual valve shall be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance WARNING Do not use aerosol sprays in the vicinity of this appliance while it is in operation Requirements Room ventilation Location and venting ATTENTION An exhaust fan may be used with the appliance in each case it shall be installed in conformity with the national standards in force ATTENTION Exhaust hood operation may affect other vented appliances in each case it shall be installed in conformity with the national standards in force INSTALLATION MANUAL WORKTOP FRONTGUARD INSTALLATION INSTRUCTIONS In order to increase the clearance between front edge of the worktop and the burners for your safety it is recomended to install the worktop frontguard supplied with the appliance For installation instructions follow the instructions indicated in the following figures PROXIMITY TO SIDE CABINET INSTALLATION 1 This rangetop may be installed directly adjacent to existing 36 91 5 cm high base cabinets IMPORTANT The top grate support MUST be 3 8 95 cm above the adjacent base cabinet countertOP 2 The rangetop CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or other side vertical surfaces above 36 91 5 cm high There must be a minimum
4. 7 8 1023 8 180 260 862 3 1023 8 220 260 WARNING check the position of the burner caps before operation Correct usage of pans Dry the bottom of the pan before placing it on the hotplate Use pots with a flat thick bottom except for wok cooking When using the burners ensure that the handles of the pans are correctly positioned Keep children away from the appliance When cooking foods with oil and fat which are very flammable the user should not leave the appliance unattended WOK PAN To use the wok pan please utilize a suitable wok adaptor grid wok pan external diameter shall not be less than 10 25cm and not more than 16 40cm 11 WARNING If the power is cut off the burners can be lit with matches The burners equipped with a safety thermocouple can only be lit when the knob is in the MAXIMUM position large flame etching CLEANING THE APPLIANCE Never use abrasive cleaners Before cleaning the appliance it should be disconnected from the power supply Cleaning the work surface periodically clean the burner heads the cast iron pan supports and the burner caps using warm water Any spillage must always be removed as soon as possible using a rag If it become difficult to open or close a valve do not force it but immediately request the assistance of the technical service personnel Cleaning the enamelled parts Enamelled parts should be cleaned frequently w
5. IPTIONS DESCRIPTIVE CAPTION FOR HOB DESCRIPTION OF HOBS 1 Small Burner Model CB36500X CB36M500X C3WO U or A 7X 2 or 5 AJFig A 2 Medium burner Model CB36600X CB36M600X C8Y0 U or A 7X 2 or 5 AJFig B 3 Rapid burner 4 Dual burner Fig A CONTROL PANEL DESCRIPTION On the control panel small symbols show the function of each knob or key Here as follows are the several controls that a cooker can have the symbol shows the disposition of burners on the worktop the full dot identifies the burner in object in this case the front burner on the right WARNINGS Keeping appliance area clear and free from combustible materials gasoline and other flammable vapors and liquid Do not store dangerous or flammable material in the cabinet areas above appliance store them in a safe place in order to avoid potential hazards A WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may resul in carbon monoxide poisoning For safe use of appliance do not use it for space heating Do not use aerosol sprays in the vicinity of this appliance while it is in operation 10 USING BURNERS A diagram is etched on the control panel above each knob which indicates which burner corresponds to that knob LOW DUAL INNER Manual ignition Manual ignition is always possible even when the power is cut off or in the event of prolonged power failure Turn the knob that corresponds to the burner s
6. Installation Service and User Instructions Built in gas cooktops all BERTAZZONI DIMENSIONS 36 915 mm W x 253 16 640 mm D Models CB36500X CB36M500X c3wo U or A 7X 2 or 5 A Models CB36600X CB36M600X C3Y0 U or A 7X 2 or 5 A IMPORTANT PLEASE READ AND FOLLOW Before beginning installation please read these instructions completely and carefully Do not remove permanently affixed labels warnings or plates from the product This may void the warranty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference The electrical plug should always be accessible Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSIZ223 1 latest edition Electrical installation must be in accordance with the National Electrical Code ANIS NFPA70 latest edition and or local codes IN CANADA Installation must be in accordance with the current CAN CGA B149 1 National Gas Installation Code or CAN CGA B 149 2 Propane Installation Code and or local codes Electrical installation must be in accordance with the current CSA C22 1 Canadian Electrical Codes Part 1 and or local codes Installation of any gas fired equipment should be made by a licensed plumber A manual gas shut off valve must be installed in the ga
7. be removed The interior of the oven should be washed thoroughly with hot soapy water to remove film residues and any installation dust or debris before being used for food preparation then rinsed and wiped dry Solutions stronger than soap and water are rarely needed 2 Ali stainless steel body parts should be wiped with hot soapy water and with a liquid deaner designed for this materia If buildup occurs do not use steel wool abrasive cloths cleaners or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wood or nylon scraper Do not use a metal knife spatula or any other metal tool to scrape stainless steel Scratches are almost impossible to remove NOTE These installation instructions should remain with the unit for future reference The electrical diagram is located in the backside or the ccoker REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the appliance Replacement parts are available from factory authorized parts distributors CONVERSIONE TO DIFFERENT TYPES OF GAS Before carrying out any maintenance work disconnect the appliance from the gas and electric supply For Natural Gas fit regulator assembly described in Fig Adaptation of the pressure regulator for use with different type of gas The pressure regulator supplied with the appliance is a convertible type pressure regulator for use
8. d service agency 3 Damage or repair service to correct service provided by an unauthorized agency or the use of unauthorized parts 4 Installation not in accordance with local electrical codes or plumbing codes 5 Defects or damage due to improper storage of the product 6 Defects or damage or missing parts on products sold out of the original factory packaging or from displays 7 Service calls or repairs to correct the installation of the product and or related accessories 8 Service calls to connect convert or otherwise repair the electrical wiring and or gas line to properly use the product 9 Service calls to provide instructions on the use of a Bertazzoni product 10 Repair service due to product usage in manner other than what is normal and customary for home use 11 Replacement of wear and tear parts 12 Replacement of glasses and light bulbs if they are claimed to have failed later than 30 days after installation and in no case later than 4 months after date of purchase 13 Defects and damages arising from accident alteration misuse abuse improper installation 14 Defects and damages arising from transportation of the product to the home of the owner 15 Defects and damage arising from external forces beyond the control of Bertazzoni SpA such as fire flood earthquakes and other acts of God In case the product will be installed in a remote area where certified trained technicians are not reasonably available the customer wil
9. d useful without affecting the essential safety and operating characteristics This appliance has been designed for non professional domestic use only A WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may resul in carbon monoxide poisoning Warning do not use this appliance to heat a room Installation instructions This appliance shall only be installed by an authorized person This appliance shall be installed in accordance with the manufacturer s installation instructions IMPORTANT this appliance must be installed in accordance with the norms amp standards of the country where it will be installed The installation of this appliance must conform to local codes and ordinances In the absence of local codes Installations must conforms to American National Standards National Fuel Gas Code ANSI 2223 1 latest edition or B149 1 If local codes permit a flexible metal appliance connection with the new AGA or CGA certified design max 5 feet 1 5 m long 2 I D is recommended for connecting this appliance to the gas supply line Do not bend or damage the flexible connector when moving the appliance The pressure regulator has 12 female pipe thread The appropriate fitting must be determined based on the size of your gas supply line the flexible metal connector and the shutoff valve The appliance when installed must be electrically grounded in accordance with local codes or in
10. e burners and unscrew the nozzles Fig using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE shown below Models CB36600X CB36M600X C3Y0 U or A 7X 2 or 5 A Adapting to different types of gas Burner Position By pass BTU h BTU h diam mm Axlay o Froth 092 _ eS 3750 1098 ry 900 264 Regulated LP Propane 17 3750 1098 900 264 _ 0 29 Regulated Front C 0 36 Rear R 2046 Regulated 0 47 Front L Inner 0 80 NG 4 2730 799 900 264 Regulated Dual Burner LP Propane 2900 Front L Outer N 2x 1 30 15000 Regulated N 2 x 0 83 _ LP Propane 16400 Models CB36500X CB36M500X c3wo U or A 7X 2 or 5 A Adapting to different types of gas Pressure Max Rate By pass Type i w c Diam mm Regulated LP Propane 1098 0 29 LP Propane 6300 1845 1500 0 36 10400 2046 2500 Regulated LP Propane 11 3339 0 47 Centre Inner 2730 799 900 264 Regulated 849 900 264 0 29 7 o0 I 200 NG 7 Regulated ir 1500 4 Centre Outer N 2x 1 30 4394 4500 1319 Regulated N 2 x 0 83 LP Propane 4804 4500 1319 0 65 CAUTION save the orifices removed from the appliance for future use Regulation of burners Work surface burner adjustment follow the instructions below to adjust the work surface burner minimum 1 Light the burner and set the
11. elected counterclockwise to the MAXIMUM position at the etched star large flame and place a lit match up to the burner Automatic electric ignition Turn the knob that corresponds to the burner selected anticlockwise direction to the MAXIMUM position at the etched star large flame and then press the knob down to activate the spark ignition Once ignited keep pressing the knob for about 10 seconds to allow the flame to heat the thermocouple If the burner does not remain alight after releasing the knob repeat the above procedure Note It is recommended not to try to ignite the burner if the relative flame cap is not in the correct position Note Dual burner is composed by two burner inside and outside each one operates under the relative gas valve indipendently from the other one Tips for using burners correctly WARNING During use of each gas burner s adjust the burner flame size properly so it does not extend beyond the edge of the cooking utensil This is an instruction based on safety considerations Use suitable pots for each burner see Fig and Table When the liquid is boiling turn down the knob to the MINIMUM position Always use pots with a cover Correct flame aspect verify that aspect flame of the worktop burners be completely blue and with an aspect as indicated in figure flame Table Burner s __ Recommended pan diameters inches mm _ 35 2 551 8 90 140 551 8 1023 8 140 260 70
12. he date of installation COVERAGE INFORMATION Bertazzoni SpA will repair or replace any component part which fails or proves defective due to materials and or workmanship within 2 years from the date of installation and under conditions of normal residential use Repair or replacement will be free of charge including labor at standard rates and shipping expenses Repair service must be performed by a Bertazzoni Authorized Service Center during normal working hours COSMETIC WARRANTY Bertazzoni will cover parts showing cosmetic defects in material and workmanship for a period of thirty 30 days from date of installation of the unit This coverage will include scratches stains surface imperfections on stainless steel paint and porcelain with the exclusion of slight differences in color due to materials and painting enamelling technologies Exclusions are labor costs B stock items out of box appliances and display units HOW TO OBTAIN SERVICE To obtain warranty service please contact Bertazzoni Customer Service at the numbers below and provide model number serial number and date of purchase ENGLISH 866 905 0010 FRANCAIS 800 561 7265 Save proof of original purchase or of original installation to establish warranty period Copy of the product serial tag is affixed to the back cover of the instruction manual WHAT IS NOT COVERED The product used in any commercial application 2 Repair service provided by other than a Bertazzoni authorize
13. ith soapy water Never use abrasive powder Do not leave acidi or alkaline substances on the enamelled parts Such as vinegar lemon juice salt tomato sauce etc and do not wash the enamelled parts while they are still hot Cleaning the stainless steel parts Clean the parts with soapy water and dry them with a soft cloth The shine is maintained by periodically using specific stainless steel cream cleaner Never use abrasive powders Use specific stainless steel cream cleaner to eliminate the glue remains afther the elimination of the blue plastic protection film on the worktop after installation Cleaning the burner caps Lift the burner caps from the burner heads and wash them in soapy water and dry thoroughly Before replacement on the burner head ensure that the holes are not clogged ATTENTION for further details about cleaning of the appliance please contact your applliance retailer 12 Please kindly register on our web site www bertazzoni com to validate your new product warranty and help us to assist you better in case of any inconvenience TWO YEAR LIMITED WARRANTY The warranties provided by Bertazzoni Spa in this statement apply exclusively to Bertazzoni appliances and accessories sold as new products to the original owner by a Bertazzoni authorized distributor retailer dealer or service center and installed in the United States and Canada The warranties provided in this statement are not transferable and have validity from t
14. l be responsible for the transportation costs for the delivery of the product to the nearest authorized service center or for the displacement costs of a certified trained technician Bertazzoni does not assume any responsibility for incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state or province to province 13 AFTER SALE SERVICE Please note here below details for after save service Refer to warranty certificate for warranty condiftions Dealer Importer Name address phone SERVICE CENTERS MANUFACTURER BERTAZZONI SPA VIA PALAZZINA 8 42016 GUASTALLA REGGIO E ITALY Tel 0522 226411 telefax 0522 226440 http www bertazzoni com
15. lled in definitive position b Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company Please provide the service person with this manual before work is started on the range Gas conversions are the responsibility of the dealer or end user c This range can be used with Natural or LP Propane gas It is shipped from the factory adjusted for use with natural gas d Manifold pressure should be checked with a manometer natural gas requires 4 0 W c P and LP Propane requires 11 0 W C P Incoming line pressure upstream from the regulator must be 1 W c P higher than the manifold pressure in order to check the regulator The regulator used on this range can withstand a maximum input pressure of 1 2 PSI 14 0 W c P If the line pressure is in excess of that amount a step down regulator will be required e The appliance its individuai shut off valve and pressure regulator must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1 2 psig 3 45kPa f The appliance must be isolated from the gas supply piping system by closing its individuai manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa 3 Flexible Connections a If the unit is to be installed with flexible couplings and or quick disconnect fittings the installer must use a hea
16. of 6 15 2 cm side clearance from the rangetop to such combustible surfaces above the 36 91 5 cm counter height 3 3 Within the 6 15 2 cm side clearance to combustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop 4 4 Wall cabinets above the rangetop must be a minimum of 36 91 4 cm for the open top burner models and a minimum of 42 106 7 cm for the sealed burner models above the rangetop cooking surface for the full width of the rangetop This minimum height requirement does nQ1 apply if a rangehood is installed over the cooking surface A 6 15 2cm MIN _ P 30 91 D D MiG 0mMAX 120 VAC 60 Hz withing 48 122 9cm of right rear or rangetop COOKER HOOD INSTALLATION The bottom of the hood should be 25 1 2 65 cm min to 31 80 cm above the countertop Refer to the rangehood installation instructions for additional information These dimensions provide for safe and efficient operation of the hood 251 2 65cm min 311 2 80cm max Cs ELECTRICAL CONNECTION This unit is manufactured for a polarized grounded 120 volt 60 Hz 16 amp system Electric power consumption is about 1 W The minimum of 102 VAC is required for proper operation of gas ignition systems This circuit must be grounded and properly polarized The unit is equipped wi
17. s supply line ahead of the oven in the gas flow for safety and ease of service In Massachusetts All gas products must be installed by a Massachusetts licensed plumber or gasfitter A T handle type manual gas valve must be installed in the gas supply line to this appliance IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE OBSERVE ALL GOVERNING CODES AND ORDINANCES WARNING If the information in this manual ts not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas suppliers call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 310496 WARNING Read this instruction booklet before installing and using the appliance The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance The manufacturer reserves the right to make changes to its products when considered necessary an
18. the absence of local codes with the National Electrical Code ANSI NFPA 70 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system any pressure testing of that system at test pressure in excess of 1 2 psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa For use with a pressure regulator The regulator supplied must be used with this appliance it shall be properly installed in order to be accessible when appliance is installed in its final location The gas appliance pressure regulator must be set for the gas with which the appliance is used This appliance can be used with Natural Gas and LP Gas It is shipped from the factory adjusted for use with Natural Gas CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK SUPPLIED WITH THE UNIT A gas nozzle kit for the change of type of gas are contained inside the package tigether with the gas appliance installation kit and instruction booklet The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20 water column 5 kPa The minimum gas supply pressure for checking the regulator setting shall be at least 1 w c 249 Pa above the inlet specified manifold pressure to the appliance this operating pressure is
19. tth a SUT power cord and in case of replacement the cable shall be replaced with one of the same type size and length WARNING Electrical Grounding Instructions This appliance is equipped with a three prong plug for your protection against shock hazard and should be plugged directly into a properly grounded socket Do not cut or remove the grounding prong from this plug WARNING ELECTRICAL SHOCK HAZARD e Disconnect electrical power at the circuit breaker box or fuse before installing the appliance e Electrically ground appliance e Use copper conductors only Failure to follow these instructions could result in seriuos injury or death Wiring diagram For freestanding gas range model CB36600X C3Y0 U7X 2 or 5 A CAUTION label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WORKTOP IGNITION SWITCHES we Supply cable type SUT 3x16AVVG with 2 poles earth fused U S Plug lenght 1 5m Black line L SPARK N W GENERATORI C E L E SPARKS il G SPARK N pA GENERATOR2 i E 5 SPARKS LEGENDA COLOR WIRES G GREEN EARTH B BLACK LINE WE WHITE NEUTRAL For freestanding gas range model CB36500X C3WO0 U7X 2 or 5 A CAUTION label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WORKTOP IGNITION SWITCHES
20. vy duty AGA design certified commerciai flexible connector of at least 1 2 1 3 cm ID NPT with Suitable strain reliefs in compliance with ANSI Z21 41 and Z21 69 standards b In Massachusetts The unit must be installed with a 36 3 foot long flexible gas connector c In Canada CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 quick disconnect device for use with gas fuel CAUTION Leak testing of the appliance shall be conducted according to the manufacturer s instructions Before placing the oven into operation always check for leaks with a soapy water solution or other acceptable method DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS PERFORMANCE CHECKLIST All burners are tested before leaving the factory There are no adjustments for the burners if connected according to the information on the rating plate Check each burner for proper operations Flames should be blue in all settings If service is required contact your dealer for the name of their authorized servi ce agency Gas conversions and initial installation are not the responsibility of the manufacturer The installer should carry out the following performance checks Refer to instructions below 1 Check surface burner ignition 2 Check low flame adjustment surface burner valve center stem adjustment 3 Check for gas leaks odors at ali gas connections FINAL PREPARATION 1 Some stainless steel parts may have a plastic protective wrap which must
21. with Natural Gas at a nominal outlet pressure of 4 w c or LP gas at a nominal outlet pressure of 11 w c and it is pre arranged from the factory to operate with one of these gas pressure as indicated in the pre arranging labels affixed on the appliance package and Instruction booklet To convert the regulator for use with the other gas different from which one it is pre arranged it is enough perform the following operations 1 Unscrew by hand the upper metal stopper of the regulator 2 Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper afterward screw it again in opposite way under the metal stopper for gas reference see the written LP and NAT with relative indicating arrows on the white piece 3 Screw again by hand the metal stopper in the original position on the regulator Operating in this way the gas regulator is converted for use with the other gas pressure lt is essential that the gasket and the pressure test point stopper are properly installed to avoid gas leakage GAS PIPE ELBOW GAS CONNECTION GASKET _ GAS CONNECTION ADAPTOR 1 2 NPT WITH S PRESSURE TEST POINT 1 8 NPT TO BE FIXED ___ _ TOWARD EXTERNAL SIDE OF THE APPLIANCE Ltd ca 7 3 PRESSURE TEST POINT STOPPER PRESSURE REGULATOR CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS To change the nozzles of the burners use the following procedure Lift up th