Home
USER`S MANUAL
Contents
1. 10 C Error due to supply voltage changes lt 0 1 Influence of serial interferences 50Hz lt 0 16 Influence of parallel interferences 220V lt 0 16 Influence of supply voltage changes lt 0 1 Additional error due to sinusoidal vibration lt 0 1 Additional error due to magnetic field lt 0 1 Edition 1 A 08 15 CPLISENS IO ATL ENG 10 2 Conditions use transportat and storage Normal conditions of use Ambient temperature 25 80 C Relative humidity 30 80 Atmospheric pressure 80 120kPa Fixed and variable magnetic field 0 400A m Ripple voltage 2V inter peak value Sinusoidal vibration 5 80HZ Up to 2g Dustiness Any Working position Any Concentration of active components in the N o aggresive components atmosphere Heating time 15min Limit conditions for transport and storage Ambient temperature 25 85 C Relative humidity Up to 95 for 40 C Shock Up to 10g 10ms 10 3 Housing weight Housing type 859 WAGO Dimensions See point 6 2 Housing ingress protection IP 20 Weight 0 1kg 7 Edition 1 A 08 15 IO ATL ENG PLISENO 11 INSPECTIONS SPARE PARTS 11 1 Periodic inspections Periodic inspections should be carried out in accordance with regulations binding the user During the inspection check all electrical connections at the terminals reliability of connections and the stability of the transmitter mounting 11 2 Unscheduled inspections If the transmitter is insta
2. IO ATL ENG Edition 1 A 08 15 PLISEN Produkcja Przemys owej Aparatury Pomiarowej i Element w Automatyki USER S MANUAL Rail mounted temperature transmitter ATL APLISENS S A 03 192 Warszawa ul Morelowa 7 tel 48 22 814 O7 77 fax 48 22 814 07 78 www aplisens pl e mail aplisens aplisens pl Symbols used Warning to proceed strictly in accordance with the information contained in the documentation in order to ensure the safety and full functionality of the device Information particularly useful during installation and operation of the device Information on disposal of used equipment BASIC REQUIREMENTS AND SAFE USE The manufacturer will not be liable for damage resulting from incorrect installation failure to maintain the device in a suitably functional condition or use of the device other than for its intended purpose Installation should be carried out by qualified personnel having the necessary authorisation to install electrical and pressure measuring devices The installer is responsible for performing the installation in accordance with these instructions and with the electromagnetic compatibility and safety regulations and standards applicable to the type of installation In the installation with control and measurement instruments exists in case of leakage a risk to personnel on the side where the medium is under pressure All safety and protection requirements must be observed during install
3. ation operation and inspections If a device is not functioning correctly disconnect it and send it for repair to the manufacturer or to a firm authorised by the manufacturer In order to minimise the risk of malfunction and associated risks to personnel the device is not to be installed or used in particularly hostile conditions where the following risks occur Possibility of mechanical impacts excessive shocks and vibration Excessive temperature fluctuation Condensation of water vapour dust icing Changes in the manufacture of transmitters can overtake the update s paper documentation Current manuals can be found on the manufacturer s website at www aplisens pl ELSE IO ATL ENG CONTENTS l INTRODUC HON BE 2 2 EERSTEN 2 3 USER KIEREN 2 4 TRANSPORT AND STORAGE esemae ozna eoaeaenanazaaeaaaanaaewzna naa 2 Am WAM SOON EEN 2 e OAO a EE AE 2 3 WARRANTY seroren rnar E O O AA GA G RA RE 3 0 CONSIRUCTION BE 3 6 1 Intended USE and FUNCTIONS aaa secs seteeeeeeceeteeenseteeeeeeeaeeeeeeeeteeeeeeteeseeeeeteeegaees 3 0 2 Construction and GIMENSIONS E 4 l INSTALLATION MN 4 Fate eet ee le Ee Een EE 4 5 CONNECTION EEN 5 3 CONFIGURATION Goin OO EE ORAS OE WE 5 NO TEGNNICAL DA KM 6 10 1 Electrical parameters cece cecceeceeceeceeceeseececeseeseecaeeaeeseeeeeeeeseeseeeeeseeeeeseeseeseesaees 6 10 2 Conditions use transportat and storage ccccecceccs
4. eeceeeseeceeeeeeseeteeeeeeeeeeeeeeeeeeeeneeees 7 10 E ere BE e EE T 11 INSPECTIONS SPARE PRIS E E 8 111A PENOBIEINEDSCHON S nin OE AE AE AP A RE AR EPE oO A RAA 8 11 2 MNSCHCOUIE later e A 8 eg E ed le n fo od 072 ERE eee nee OGAE A 8 LIST OF FIGURES Figure 1 ATL transmitter DIMENSIONS cccccccecceecceeceeeceeceeeeeeceeceeeseesaeeeeeseesaeeaeeseeeeeaaes 4 Figure 2 Connection of ATL transmitter ccc ccccccceccseeceeeceeeceeeeeeeeeeseeeseeesaeeseeseeeseeeseeees 5 Edition 1 A 08 15 IO ATL ENG PLISENO 1 INTRODUCTION The subject of this manual is rail mounted temperature transmitter type ATL This manual contains data information and recommendations concerning installation and use of the transmitter as well as troubleshooting procedures 2 SAFETY PROCEDURES The installation and commissioning of the transmitter and any activities related to the operation should be performed only after careful examination of the contents of this manual Installation and maintenance should be carried out by qualified personnel having necessary authorisation to install electrical equipment and measuring instruments The transmitter should be used according to its intended purpose section 6 1 with permissible parameters Before assembly or disassembly of the transmitter one must absolutely disconnect the power source Under no circumstances may the electrical system of the transm
5. itter be repaired or otherwise handled by the user Damage assessments and repairs may only be carried out by the manufacturer or its authorised dealer Do not use damaged device If a device is not functioning correctly disconnect it 3 USER MATERIALS The user receives together with the transmitter a Product Certificate which is also a warranty card b User Manual ref No IO ATL ENG available on the website www aplisens pl 4 TRANSPORT AND STORAGE 4 1 Transport Transmitters should be transported in multi or and single unit packaging The packaging should be protected against displacement and direct weathering effect 4 2 Storage The transmitter should be stored in the original packaging indoor rooms free of vapours and corrosive substances the temperature and relative humidity should not exceed the permitted conditions see p 10 2 Edition 1 A 08 15 CPLISENS IO ATL ENG 2 WARRANTY Manufacturer warrants to the conditions specified in the Product Certificate which is also a guarantee card Warranty is in full force under the condition of using the devices properly along with the purpose determined in the manual Warranty does not apply to devices which are damaged mechanically or electrically through occurrences not attributable to Aplisens especially l Damage in connection with installation or activating Damage in connection with improper usage or usage against manual or safety regu
6. lations 6 CONSTRUCTION 6 1 Intended use and functions Temperature transmitters tyoe ATL are designed for temperature measuring in various industrial applications related to measurements control and regulation Temperature transmitter converts the measurement signal from RTD temperature sensors to signal 4 20 mA The ATL transmitter features e wo wire power supply 4 20mA current loop signal Digital signal processing filtration linearization Ability to remote selection of the range and type of sensor Sensor signal interrupt information Sensor break alarm Ability to cooperate with resistive Pt100 Ni100 sensors Resistance compensation in the line connecting the resistive sensor to the transmitter in three wire cable Edition 1 A 08 15 IO ATL ENG PLISENO 6 2 Construction and dimensions Temperature transmitter type ATL consist of a sealed housing of plastic material and the electronic unit placed inside that converts signal from the sensor to a unified output signal The transmitters have two output terminals and three input terminals Additionally ATL transmitter is equipped with a input for programming input for programming 8 62 log 91 Figure 1 ATL transmitter Dimension
7. lled in a location where it could be subjected to mechanical damage electrical surges or malfunction is found inspect it as needed In case of lack of signal in the transmission line or its incorrect value check the state of the cable of the connection on terminals etc Determine whether the values of the supply voltage and load resistance are correct 12 SCRAPPING DISPOSAL Waste or damaged transmitters should be dismantled and disposed of in accordance R with Directive 2002 96 EC on waste electrical and electronic equipment WEEE or returned to the manufacturer Edition 1 A 08 15
8. s 7 INSTALLATION 7 1 General recommendation It is recommended to install transmitters in closed enclosures to protect them against influence of the environment Rail mounted enclosure allowsfor installation on the following rail types e TS 32 EN 50 035 e TS 35 EN 50 022 Edition 1 A 08 15 PLISENO IO ATL ENG 8 CONNECTION N All connecting and assembly operations must be done with a disconnected power supply and disconnected input signal Connect the transmitter according to Figure 2 Cable diameter lt 2 5mm ma Konwerter GND Rx Tx TTT Figure 2 Connection of ATL transmitter 9 CONFIGURATION Transmitter can be configured by RS USB converter connected to PC with transmitters configuration software attached to converter During configuration transmitter should be supplied by 9 36V DC ATL transmitter is equipped with a programming slot located on the front of enclosure Fig 1 Edition 1 A 08 15 IO ATL ENG PLISENS 10 TECHNICAL DATA 10 1 Electrical parameters Input signal Pt100 Ni100 Limit process 200 lt R lt 3800 Min measuring range 100 Output signal 4 20mA Power supply Uz 6 29V Load resistance Ro 0 Uz 7V 25mA Output updates time time constant lt 1s Alarm signal gt N j lt 3 8mA Processing error lt 0 2 Accuracy for AR gt 20 Q min 0 25 C 0 1Q Thermal error lt 0 1 10 C Additional for the resistive output lt 0 25 C 0 10