Home

USER MANUAL - Traxon Technologies

image

Contents

1. as shown above e Connect the AC power cable 100 240VAC to the first 3 terminals L N Make sure the panels are properly positioned and securely installed before use IMPORTANT NOTE e The length of each DC power cable should not exceed 15m 49 5ft 18 AWG wire e To prevent overheating and overloading do not tamper with the dc power cable e Make sure that only one panel is connected to each dc power cable THE CONNECTION OF THE POWER SUPPLY SHOULD ONLY BE HANDLED BY QUALIFIED TECHNICIAN THE MANUFACTURER BEARS NO RESPONSIBILITY FOR ANY MALFUNCTION OR DAMAGE CAUSED BY IMPROPER ELECTRICAL INSTALLATIONS ENSURE THAT THE POWER SUPPLY IS SWTICHED OFF BEFORE CONNECTING OR DISCONNECTING PANELS 4 4 CONTROL For configuration of the individual pixels per set of 2 panels please refer to the standard DMX chart below Fig 4 Please note that you can modify the DMX channel allocation to suit your specific project using Traxon Light Management software Please refer to the Butler L_M CS 50041 user manual for configuration details FIG 4 DMX ADDRESSING RGB CHANNELS Frist Panel 1 3 25 27 49 51 73 75 97 99 121 123 145 147 169 171 Second Panel 193 195 217 219 241 243 265 267 289 291 313 315 337 339 361 363 Frist Panel 4 6 28 30 52 54 76 78 100 102 124 126 148 150 172 174 Second Panel 196 198 220 222 244 246 268 270 292 294 316 318 340 342 364 366 Frist Panel T9 31 33 55 57 79 81 10
2. 3 105 127 129 151 153 175 177 Second Panel 199 201 223 225 247 249 271 273 295 297 319 321 343 345 367 369 Frist Panel 10 12 34 36 58 60 82 84 106 108 130 132 154 156 178 180 Second Panel 202 204 226 228 250 252 274 276 298 300 322 324 346 348 370 372 Frist Panel 13 15 37 39 61 63 85 87 109 111 133 135 157 159 181 183 Second Panel 205 207 229 231 253 255 277 279 301 303 325 327 349 351 373 375 Frist Panel 16 18 40 42 64 66 88 90 112 114 136 138 160 162 184 186 Second Panel 208 210 232 234 256 258 280 282 304 306 328 330 352 354 376 378 Frist Panel 19 21 43 45 67 69 91 93 115 117 139 141 163 165 187 189 Second Panel 211 213 235 237 259 261 283 285 307 309 331 333 355 357 379 381 Frist Panel 22 24 46 48 70 72 94 96 118 120 142 144 166 168 190 192 Second Panel 214 216 238 240 262 264 286 288 310 312 334 336 358 360 382 384 5 TROUBLESHOOTING Problem Solution Panels cannot be installed close together Ensure the installation surface is flat and smooth Duplicated images appear e Both panels have been set to the same starting address e Check each panel s DIP switch setting Images do not show on the connected panels e Data cable length exceeds 100m 330ft e Check the connections of the Butler and panels e Check that the power supply is connected to the panels and the power is ON e Check th
3. Ccrascom CREATIVE LIGHTING TECHNOLOGIES USER MANUAL Tile 64 PXL Wash Please check for the latest updates and changes on the TRAXON website i TRAXON TECHNOLOGIES ALL RIGHTS RESERVED Tile 64 PXL Matrix Mirror 64PXL Wash WWW TRAXONTECHNOLOGIES COM HONG KONG NEW YORK PARIS TOKYO RIO DE JANEIRO FRANKFURT MELBOURNE SHANGHAI BIRMINGHAM ROTTERDAM Manual Version 1 0 USER MANUAL INDEX KR O N N INTRODUCTION P1 CONTENTS P2 SAFETY AND PRECAUTIONS INSTALLATION AND SYSTEM CONFIGRATION P4 9 4 1 MOUNTING P4 4 2 DATA CONNECTION P5 6 4 3 POWER CONNECTIONS P7 8 4 4 CONTROL P9 TROUBLESHOOTING P10 CARE AND MAINTENANCE P11 TECHNICAL SPECIFICATION 11 12 WARRANTY STATEMENT P12 FOR YOUR OWN SAFETY AND THAT OF THE PRODUCT PLEASE READ THIS USER GUIDE CAREFULLY BEFORE BEGINNING SET UP AND INSTALLATION CAUTION DO NOT OPEN OR HANDLE THE PANELS EXCEPT AT A STATIC FREE WORKSTATION OR WEARING AN ANTISTATIC WRIST STRAP 1 INTRODUCTION 1PXL SERIES TILE 64PXL WASH PA TI 50300 TILE 64PXL MATRIX PA TI 50200 MIRROR 64PXL WASH PA MI 50300 These products are part of the Traxon Panels product line enabling a flexible setup of medium to large scale RGB LED color changing walls The 64PXL panels feature each 64 individually addressable pixels for full programming liberty While the Wash versions enable optimal video replay capabilit
4. e Butler DMX controller configuration No power supply e DC power cable length exceeds 15m 49 5ft e Wrong connection to power supply refer to page 7 10 11 6 CARE AND MAINTENANCE Traxon products are of superior design and quality and should be treated with care The recommendations below will help fulfill and warranty obligations and gain good use and longevity from the products Make sure that the product s is installed correctly and securely For indoor use only Keep product in a dry and precipitation free area as this with damage the product s electronics Keep product s in a dirt and dust free environment Keep product s in an extreme heat free area and ensure that it has sufficient airflow and cool air circulation if required Do not attempt to service or repair the product s unless done by an authorized service again Contact the local Traxon office or distributor for details Do not drop knock or shake the product s as rough handling may damage the electronics and void the warranty Do not use harsh chemicals cleaning solvents or strong detergents to clean wipe with a damp cloth on housings and a dry cloth on electronics to remove and buildup of dirt or dust If the product is not working correctly please contact your nearest authorized service centre or Traxon Technologies office for assistance 7 TECHNICAL SPECIFICATIONS TILE 64 PXL WASH MIRROR 64PXL WASH Color
5. ext panel Data Cable from DMX out to DMX IN on next panel DMX Data Cable 2 DATA CONNECTION BUTLER LM CS 50041 Each butler can connect max 4 panels 2 2 pcs Data cable max length 100m 330ft from DMX controller to the last fixture using cable In this configuration the Butler draws power directly from the 64PXL panels and does not require any external power supply 4 3 POWER CONNECTIONS Connect the 64PXL panels to an external 24V power supply as shown in the connection diagram below Fig 3 FIG 3 CONNECTOR BLOCK 2P BLACK WIRE 18 AWG BLACK WIRE WITH WHITE HIDDEN LINE 18 AWG V AC PS 00009 POWER SUPPLY Max 4 panels per power supply SPADE TERMINAL DC POWER CABLE N DC POWER CABLE 1st FIXTURE Max 15m 49 5ft DC POWER CABLE TO 2nd FIXTURE AC POWER CABLE 100 240VAC To power input of panel Each 24V System Power Supply 320W AC PS 00009 can power up to 4 panels ake sure the panels are properly positioned and securely installed before connecting the power e Connect the DC OUT of the 24V System Power Supply to the POWER INPUT located at the back of each panel using a DC power cable Connect the black wire 18AWG to V and the black wire with white line 18AWG to V e Connect the DC power cables for the 3rd and 4th panels to the same terminals on the power supply
6. he wall Use of the supplied wall mount accessories is strongly recommended For the best visual effect mount on an even surface CAUTION DO NOT INSTALL THE PANEL IF THE COVER SHIELD IS DAMAGED 4 2 DATA CONNECTION 4 2 1 ADDRESS SETTING Each Butler can control 2x2 panels of 192 DMX channels each in a daisy chain configuration i e maximum 4 panels Each panel s starting address range is set using DIP switches on the rear of the panel For each set of 2 panels Set the first panel s DIP1 switch to OFF address range 1 192 Set the second panel s DIP1 switch to ON address range 193 384 All the other DIP switches should be set to OFF The 64PXL panels are controlled by Traxon Butler LM CS 50041 or standard DMX512 Ethernet to DMX Gateway units Each Butler can control 2 sets of 2 panels for a total of 4 panels 2 x 512 DMX channels Connect the panels to the Butler using the supplied CAT5e patch cables Pin1 DMX Pin2 DMX Pin3 GND as shown in the diagram below Fig 2 FIG 2 ONLY QUALIFIED PERSONNEL SHOULD INSTALL THIS PRODUCT INSTALLATIONS MUST COMPLY WITH LOCAL REGULATIONS ADDRESS OHHH HOU OFF OFF OFF ENSURE THAT THE POWER SUPPLY IS OFF BEFORE CONNECTING OR DISCONNECTING PANELS PANEL 4 9 IMPORTANT NOTE Length of the data cable between the Butler and the last panel should not exceed 100m 330ft Data Cable from DMX out to DMX IN on n
7. ies thanks to Traxon Light Management the Matrix version offers clearly defined pixels for sharp graphical effects Traxon Mirror 64PXL Wash additionally serves as high class black mirror when switched off High power LED technology combined with low power consumption brings the best solution possible for any number of applications TILE 64PXL WASH e 64 individually controllable RGB SMDs e Seamless color transition between 500mm 19 7 95mm 3 75 75mm 2 95 the pixels e DMX Control e RJ45 Cat5E Data Cabling FRONT BACK TILE 64PXL MATRIX 64 individually controllable RGB SMDs e Clearly defined pixels e DMX Control e RJ45 Cat5E Data Cabling MIRROR 64PXL WASH 64 individually controllable RGB SMDs e Premium reflective glass surface e DMX Control e RJ45 Cat5E Data Cabling 2 CONTENTS j 500mm 19 7 FRONT j 500 19 7 BACK FRONT BACK 95mm 3 75 75mm 2 95 1 SS 95mm 3 75 76mm 2 95 T E TOP TILE 64PXL WASH TILE 64PXL MATRIX MIRROR 64PXL WASH CES 1 X RJ45 Data Cable 1 x Panel 1 X DC Power Cable Data amp Power cables fitted 4 M4 Mounting Screws 20mm 3 SAFETY PRECAUTIONS Failure to adhere to the following instructions could res
8. resolution 3 x 14 Bit RGB Color range 16 7 million additive RGB colors with variable intensity Light source Ultra Bright SMD LED Source life 50 000 hours under normal operating conditions Beam angle 120 Power input 24VDC Current consumption maximum Power consumption 72W maximum Operating temperature range 15 C 55 C 4 F 131 Storage temperature range 40 C 70 C 40 F 158 F TILE 64 PXL MATRIX Color resolution 3 x 14 Bit RGB Color range 16 7 million additive RGB colors with variable intensity Light source Ultra Bright SMD LED Source life 50 000 hours under normal operating conditions Beam angle 120 Power input 24VDC Current consumption 35A maximum Power consumption 32 4W maximum Operating temperature range 15 C 55 C 4 F 131 F Storage temperature range 40 C 70 C 40 F 158 F 8 WARRANTY STATEMENT Traxon warrants its Products against material or workmanship defects for a period of one 1 year from the date of purchase provided that the purchased items are under conditions stated in respective instruction manuals Proof of purchase is necessary upon on warranty claim Any implied warranty of merchantability or fitness for a particular purpose or use shall be limited to the duration of the foregoing written warranty Otherwise the foregoing warranty is the purchaser s sole and exclusive remedy and is in lieu of all other warran
9. ties express or implied Traxon shall not be liable for any incidental or consequential damages or a loss of anticipated 16 All warranty information product features and specifications are subject to change without notice 12
10. ult in death serious injury or property damage and will void the product warranty DANGER ENSURE THAT MAIN POWER SUPPLY IS UNPLUGGED BEFORE INSTALLING OR WIRING THE PRODUCT CAUTION POWER DATA SUPPLY MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN OR TECHNICIAN IN ACCORDANCE WITH RELEVANT LOCAL STANDARDS AND REGULATIONS DO NOT ATTEMPT TO INSTALL OR USE THE PRODUCT UNTIL YOU HAVE READ THIS MANUAL THOROUGHLY AND UNDERSTAND THE INSTALLATION INSTRUCTIONS DO NOT USE THE PRODUCT IF ANY CABLES ARE DAMAGED An ambient operating air temperature range of 15 C 55 C 4 F 131 F must be adhered to at all times If the product has been transported or stored in low temperatures DO NOT connect it to the power supply until it has reached room temperature to prevent any internal condensation from damaging the product s electronics DO NOT expose the product to moisture extreme heat or direct sunlight Use in a clean and dust free environment 4 INSTALLATION AND SYSTEM CONFIGURATION 4 1 MOUNTING e Use a pencil or chalk to mark the horizontal alignment before installation e Install four screws to the wall Horizontal and vertical clearance between the screws should be 340mm e Hang the panel on the wall as shown in Fig 1 FIG 1 340mm 13 4 DO NOT MOUNT ON UNEVEN SURFACE 340mm 13 4 WALL MOUNT min 6mm 0 24 IMPORTANT NOTE Leave at least 6mm between the screw head and t