Home

CPAT FLEX Operation Manual (ITX2)

image

Contents

1. 2 4 Physical Overview 2 4 1 Front View Buttons and Display The ITX2 has four front panel buttons used to turn the unit on and off navigate menus confirm modifications and toggle transmission on and off Operation Manual 9 CRAT CONTINUOUS MONITORING SYSTEM LCD display On Off button Esc Mute Tx 2 4 2 Power and Data Interface The ITX2 has two interfaces on the bottom of the unit The round receptacle is used to con nect the AC adapter or the DC adapter supplied by Effigis The data interface is a USB type A receptacle and is used with the ARDA It is also used for firmware upgrades Charger adapter interface 10 CPAT FLEX ITX2 effigis com 2 4 3 Antenna Connector The ITX2 has a BNC connector on the top of the unit This interface is used to connect an antenna supplied by Effigis to transmit a low power ingress test carrier By default the por table dipole antenna is used Insert the antenna into the connector and turn slightly to lock the antenna in place 2 4 4 Battery The ITX2 is powered by a 7 2V 2000 lithium ion battery pack that has a 4 pin connec tor to interface with the unit The battery pack is charged at about 4096 when the ITX2 is shipped NOTE The battery compartment is not used because the battery pack is installed inside the unit s housing Therefore the battery compartment has been inten tionally left empty NOTE This unit does not provide audio feedback Therefo
2. Operation Manual 19 CRAT CONTINUOUS MONITORING SYSTEM NOTE The 1 and ITX2 signal will be detected and measured only if all these condi tions are fulfilled e The is an operational IRX1 receiver monitoring the search area subset of nodes The operating parameters of the transmitter ITX1 or ITX2 match those of the receiver IRX1 There is valid antenna plugged to the transmitter There is at least one ingress point within range of the transmitter a few to several meters depending on Tx level and ingress sensitivity The ITX1 or ITX2 is transmitting Remember that the higher the value the closer the ingress point 20 CPAT FLEX ITX2 effigis com 5 5 Charging the battery The ITX2 can operate on battery power for several hours when fully charged When the unit approaches a low charge state the battery indicator appears and starts to blink slowly To maintain good battery health and ensure the longest useful battery life follow these rec ommendations for charging the battery 1 Use only the battery pack and replacement battery pack available from Effigis 2 Use only the chargers available through Effigis The battery charges at a rate of 0 6 A fully discharged battery will be recharged to approximately 90 after 6 hours The ITX2 s status LED will turn off if the device is not operating or be lit green if the device is operating only when the battery is fully charged 3 Charge the
3. the USB cable Enter button From the main interface the Enter button is used to access to the settings menu When used within the settings menu s items the Enter button lets you exit the settings menu and save the last changes Operation Manual 15 CRAT CONTINUOUS MONITORING SYSTEM Arrow buttons From the main interface the up and down arrows are used to set the transmission level Mute Low Medium High In the settings menu the up right down left arrows allow you to browse and modify parameters To change the settings of an element press the right arrow gt when the cursor is over the selected element of the menu You can then choose a new value among the preset values by pressing the up or down arrow To keep a new value and return to the list of settings press the left arrow 44 or Enter To save values and exit the settings menu press the left arrow 4 again To exit the menu without saving press Esc Please refer to the Menu content section for details on configuring each element in the menu NOTE 7 When connected to the ARD4 via the USB cable the ITX2 s buttons are auto matically disabled except for the Power button Esc Tx button The Esc button is used to exit the settings menu without saving If you press Esc while the ITX2 s main interface is displayed this toggles the RF test carrier signal transmission On and Off The active transmission level will automatically be updated
4. 6 1 6 Effigis Website DR eee Heats 6 2 System Components 7 2 1 Initial Verification 7 2 2 ITX2 Optional Accessories 8 2 2 1 Vehicle accessories 8 2 9 FOURS ee a kapi de 9 2 4 Physical Overview 9 2 4 1 Front View Buttons and Display 9 2 4 2 Power and Data Interface 10 2 4 3 Antenna Connector 11 24 1 Battery oae tena eed EY ern 11 Installation 12 3 1 Using the Vehicle Support Bracket optional 12 3 1 1 Safety Precautions for Installation 12 3 1 2 Installing the Vehicle Support Bracket 13 4 Setup cos rn Ren enr 14 1 1 Sle te shana a ree a tres DP en ent a eem rm 14 4 2 MXZ SEUD eios one cree ke hh uluya ee ke wh heh de 14 5 adiu ese x gre d IRURE IRA IR Ue aa ae d 15 5 1 LOD information o E Dee eR eR Ra 15 5 2 Button TUNCIONS eR ERE REY er 15 5S Men Cnet eese CREER pati RA 16 5 4 Using the ITX2 as a portable transmitter 18 5 5 Charging the Datleny cct eee e n e a 21 5 6 Using the ITX2 for auton
5. Customer that new Effigis branded software and firmware will perform in substantial conformance to program specifications for a period of ninety 90 days from the date of original shipment Effigis warrants the media containing software against failure during the warranty period Effigis makes no warranty or representation that the operation of the software products will be uninterrupted or error free or that all defects in the software products will be corrected B 2 3 Exclusions This warranty excludes e Damage to the physical surface of the product including cracks or scratches to any part e Damage caused by misuse neglect improper installation or testing unauthorized attempts to open repair or modify the product or any other cause beyond the range of the intended use e Use of the product with any non recommended device or service if such device or service causes the problem 26 CPAT FLEX ITX2 effigis com e Installation or maintenance of Product by someone other than Effigis or persons certified by Effigis e Changes to the Customer environment in which Product was installed e Damage caused by accident fire power changes other hazards or acts of nature Consumable Product or parts thereof e g parts with an expected useful life of less than ninety 90 days such as certain batteries e Product not returned in accordance with Effigis RA procedure B 2 4 Refurbished Parts and Prior Testing Product m
6. find important safety information in this manual We strongly recommend that all users read this manual Use of this product other than for its intended application may com promise the unit s safety features 1 2 Explanation of Symbols Used The following symbols are used on the ITX2 label and in this Manual Symbol Explanation Caution Indicates that operations or procedures if carried out without caution may Cause personal injury or damage to the unit 2 Note Indicates additional information about the product 1 3 Certifications This section describes the certifications the ITX2 complies with IN PROCESS 1 3 1 Tests Specifications FCC 47 CFR Part 15 Subpart B Verification ICES 003 NMB 003 Issue 4 February 2004 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 Generic requirements 1 3 2 Compliance eee This Class A digital apparatus complies with Canadian ICES 003 NMB 003 This Class A digital apparatus also complies with European EN61326 1 2006 a en no aaaaau This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation Operation Manual 5 CRAT CONTINUOUS MONITORING SYSTEM NOTE Any modifications made to this device that are not approved by Effigis Geo Solutions Inc may void the authority granted to the user by the FCC to operate this equipment 1 4 Technical S
7. in the main interface 5 3 Menu content Tx Power The ITX2 can transmit at various levels to help you locate the source of ingress The transmission level can be set to Mute Low Medium or High The center section of the main interface of the ITX2 shows the current Tx level NOTE The transmit level can be modified directly from the main interface by using the up and down arrows on the keypad or can be muted with the Esc Tx button 16 CPAT FLEX ITX2 effigis com Antennas for 6 78 MHz ITX2 only The level of transmission is the same for all antennas associated with this product There fore the default antenna Portable dipole ant cannot be modified When connected to an ARDA the antenna selection will display Vehicle rooftop ant to remind the user to connect the ITX2 to the vehicle s monopole antenna Antennas for 27 12 MHz ITX2 only n order to provide similar results using different antennas the ITX2 adjusts the transmission evel depending on the gain factor associated with the active antenna model The associated gain can be specified from one of the following antenna types Monopole The antenna whip installed on vehicle s roof e Dipole The portable antenna used to locate ingress source e Rubber Duck Available with the 27 12 MHz version e Near field Used to locate ingress source at close range e None No antenna is used for testing purpose only NOTE Do not change the an
8. points and transmit them to the CPAT database integration process Operation Manual 24 CRAT CONTINUOUS MONITORING SYSTEM NOTE The ARD4 must have been configured previously to operate an ITX2 when one is detected That setup is performed remotely by the CPAT support team 2 NOTE The ITX2 operating parameters are by the ARD4 according to its active setup By default the ARD4 operates the ITX2 with Tx Level High and An tenna type Monopole Once the USB cable linking the ARD4 and the ITX2 is disconnected the ITX2 will keep the parameters programmed by the ARD4 NOTE The USB cable does not carry power from the ARD4 Therefore the ITX2 is powered by its battery unless the DC adaptor is plugged in and operational The battery charge cycle is the same whether the ITX2 is used with the ARD4 or not 5 7 Replacing the Battery Pack The rechargeable Lithium ion battery pack is located inside the ITX2 unit You do not need to access the battery pack unless it can no longer be recharged To change the battery pack 1 Remove the antenna and the rubber holster 2 Loosen the back compartment s screw using a Philips head screwdriver and re move the panel 3 Remove the 6 screws on the bottom part of the ITX2 s housing using a Philips head screwdriver and remove the bottom part of the case 4 Disconnect the 4 pin mating on the cable between the battery pack and the circuit board Replace the battery p
9. CPAT FLEX Operation Manual ITX2 CONTINUOUS MONITORING SYSTEM v 1 0 2014 04 28 2014 Effigis All rights reserved 006 000039 101 CRAT CONTINUOUS MONITORING SYSTEM This document provides information proprietary to Effigis and cannot be used or disclosed without Effigis written authorization Effigis reserves the right to make changes without notice Changes affecting the operation of any component in this manual will be reflected in a subsequent revision Effigis assumes no responsibility for any omissions or errors that may appear in this document or for any dam ages that may result from the use of information contained herein ITX2 User Manual irst edition v1 0 April 2014 Part No 9575 TI Published by Effigis 4101 Molson St Suite 400 Montreal Quebec CANADA H1Y 311 Telephone 1 514 495 0018 Toll free North America 1 888 495 6577 Fax 1 514 495 4191 Copyright 2014 Effigis All rights reserved 2 CPAT FLEX ITX2 effigis com Contents 1 General Information 5 1 1 About this Manual 5 1 2 Explanation of Symbols Used 5 1 3 Gertifieali fe PEE 5 1 3 1 Tests SD CITICATIQNS ane ice due du oe due ets 5 1 3 2 0ombliance s cel ER Ep TS TAS EE e 5 1 9 er Gans ua no ard 5 1 4 Technical Support 6 1 9 s a a
10. POSE AND NON INFRINGE MENT REGARDLESS OF THE LEGAL THEORY ON WHICH SUCH IMPLIED WARRANTY MAY BE BASED INCLUDING WITHOUT LIMITATION CONTRACT COURSE OF DEALING USAGE OR TRADE PRACTICE Operation Manual 27 Bl Roof Antenna 28 CONTINUOUS MONITORING SYSTEM CHAT FLEX Installation diagram Screws A gm Pp Tie wrap i Jil Vehicle DC CPAT FLEX ITX2 effigis com Holder lockplate Operation Manual 29 effigis GEO SOLUTIONS effigis com 1 888 495 6577
11. ack only with a battery pack from Effigis 5 Plug the 4 pin connector to the cable and replace the bottom part of the case Secure it with the 6 screws In order to avoid damaging the ITX2 s housing do not overtighten the screws 6 Replace the panel on the back compartment and secure it with the last screw 7 Reinstall the rubber holster and the antenna 22 CPAT FLEX ITX2 effigis com 5 8 Updating the ITX2 s Firmware From time to time firmware updates may be available for the ITX2 Effigis provides these up dates via its website Please visit the Downloads page to obtain the latest firmware release To check which version is currently installed in the ITX2 access the setup mode by pressing the left or right arrow and scroll to the Version menu Firmware updates can be automatically performed through the ARD4 To proceed manually using an ITX2 linked to a computer through the USB cable contact the CPAT support team 6 Maintenance 6 1 Cleaning Your ITX2 unit can be wiped clean with a damp cloth Do not immerse the unit in water Avoid solvents and commercial cleaners 6 2 Preventative Maintenance The technician shall do periodic visual inspections of the ITX2 to make sure that there is nothing loose or broken Both can affect the performance of the system In case that a re placement is required please contact Effigis for more information Appendix A Specifications A 1 Technical Transmitter type Digita
12. ay incorporate reconditioned or refurbished parts or subassemblies and may have been used in testing prior to sale B 2 5 Exclusive Remedies If any Product materially fails to conform to the limited warranty set forth in this Section Lim ited Warranty and actually fails during the applicable warranty period and under normal use Effigis shall at its sole discretion i repair or replace the non conforming Product to remedy the nonconformity identified by Customer in accordance with this Section Limited Product Warranty or ii issue a credit to Customer for the amounts paid for the Product in exchange for return of the non conforming Product in which case Customer s licenses to any Firmware shall be automatically revoked Customer hereby transfers to Effigis title and ownership of any parts that Effigis replaces ownership of any parts that Effigis replaces B 2 6 Disclaimer THE REMEDIES EXPRESSLY PROVIDED IN THIS SECTION WILL BE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AND SHALL BE IN LIEU OF ANY OTHER RIGHTS OR REMEDIES CUS TOMER MAY HAVE AGAINST EFFIGIS WITH RESPECT TO ANY NON CONFORMANCE OF PRODUCTS EXCEPT AS SPECIFIED IN THIS LIMITED PRODUCT WARRANTY EFFIGIS MAKES NO EXPRESS REPRESENTATIONS OR WARRANTIES WITH REGARD TO ANY PRODUCT EFFIGIS DISCLAIMS ALL IMPLIED WARRANTIES CONDITIONS AND REPRESENTATIONS IN CLUDING BUT NOT LIMITED TO ANY WARRANTIES OR CONDITIONS OF MERCHANTABILITY SATISFACTORY QUALITY FITNESS FOR A PARTICULAR PUR
13. cian s daily Work routine This section describes the ITX2 unit in detail including its accessories and helps you get started by explaining its features how to use its buttons and its powering and data inter faces NOTE The ITX2 must be used in conjunction with the IRX1 ingress monitoring system installed in the headend 2 1 Initial Verification Your ITX2 unit is 4096 charged calibrated and ready to use right out of the box Upon recep tion visually inspect each item for any damage that may have occurred during shipping If you see any signs of physical damage please contact Effigis e Callers from the U S and Canada can dial 1 888 495 6577 toll free number e International callers can dial 1 514 495 0018 If there are no apparent signs of physical damage turn on the unit by pressing the red On Off button and make sure the unit boots up properly Make sure no items are missing Your package should contain all the standard items as well as any accessories you may have ordered If you ordered the ITX2 portable ingress detection kit the following items are included 2 transmitter with rubber holster Portable dipole antenna e Belt strap e AC adapter e User manual Operation Manual 7 CFA CONTINUOUS MONITORING SYSTEM b Figure 1 Portable dipole antenna charger and ITX2 If any of the standard accessories are lost or damaged you can order a replacement for the 2 Please quote the
14. e systems may cause severe injuries To install the support bracket 1 Choose a location on the dash that does not interfere with any of the vehicle s safety features or other wiring See the 3 1 1 Safety Precautions for Installation on page 12 2 For easier installation remove the back plate from the ITX2 clip by loosening the large adjustment screw see Figure 2 Figure 2 Vehicle support bracket See the installation diagram on page 28 Operation Manual 13 CRAT CONTINUOUS MONITORING SYSTEM 3 Using the screw holes on the back plate as a template mark where you will need to pre drill holes for the screws 4 Pre drill the holes of an appropriate depth and diameter for your screws making sure that you do not damage any hidden wiring 5 Affix the back plate to the dash with the screws 6 Re attach the ITX2 clip to the support bracket s back plate using the large screw Do not overtighten 7 Place the ITX2 in the clip the vehicle rooftop antenna cable in the antenna holder and if desired attach the 12V charger s wire to the strain relief slots with a cable tie so it is readily accessible for charging 4 Setup Like the ITX1 that is permanently installed in vehicle the ITX2 needs to operate with an IRX1 in order to detect and measure ingress levels The transmitter and the receiver need to oper ate with the same parameters in order the measure and locate ingress 4 1 IRX1 setup The instal
15. following part numbers when placing an order Part No Accessory Description 3500 3430 6117 9540 9550 9575 AC adapter Replacement battery pack Portable dipole antenna Belt strap ITX2 rubber holster ITX2 user manual To place an order please call Effigis at 1 888 495 6577 or 1 514 495 0018 2 2 ITX2 Optional Accessories 2 2 1 Vehicle accessories The ITX2 comes with a portable dipole antenna for handheld ingress detection The ITX2 can also be operated by the ARD4 CPAT FLEX module installed in the service vehicle To do so the accessories listed below are required CPAT FLEX ITX2 effigis com Part No Accessories Description 9560 Vehicle support bracket 6110 Monopole 6 78 MHz Antenna Kit includes lip mount base whip antenna BNC terminated cable 6206 Vehicle magnetic mount base for RF antenna with BNC terminated cable 9860 ITX2 DC adapter 9260 ITX2 USB Cable NOTE Only antennas obtained from Effigis can be used effectively with the ITX2 Each Effigis antenna has been analyzed and the appropriate compensation has been designed into the ITX2 for optimal results Effigis cannot guarantee proper results with an antenna from any other source 2 3 Features The 2 is a find and fix transmitter for ingress detection that offers many features including User adjustable transmission level e User adjustable antenna gain e Based on Effigis CPAT FLEX ingress monitoring system technology
16. l receiver demodulator Frequency range 6 78 MHz or 27 12 MHz set at factory Bandwidth 30 kHz Radiated power Maximum 8 dBm at 6 78 MHz Maximum 12 dBm at 27 12 MHz Operation Manual 23 CONTINUOUS MONITORING SYSTEM A 2 Electrical and Environmental Inputs 12VDC 1 2A max 7 2VDC lithium ion battery pack of 2000mAh 0 AC battery charger Input 100 240V 50 60Hz 0 7 Output 12VDC 1 66A Transient overvoltage Il Rated pollution degree 2 Mains supply voltage fluctuations Up to 10 of the nominal voltage Operation time 6 hours nominal on battery power Operating temp 20 C 40 C 4 F 104 F Storage temp 20 C 45 C 4 F 113 F Recommended use Indoor use or outdoor use without exposing to direct sunshine or wet location Altitude Up to 2000 m 6560 ft Maximum relative humidity 80 for temperatures up to 31 C 88 F decreasing linearly to 50 rela tive humidity at 40 C 104 F A 3 Physical ITX2 with its rubber holster only no antenna Dimensions 7 7 x 3 4 x 1 8 Hx W xD 19 5 cm x 8 6 cm x 4 5 cm Weight 19 ounces 550 g Specifications subject to change without prior notice 24 CPAT FLEX ITX2 effigis com Appendix B Our Services Effigis offers a portfolio of services to deploy and support purchased equipment through its Customer Support organization Customer Support is standard with every product sale and consists
17. lation setup and system operation are detailed in the CPAT FLEX Operation Manu al IRX1 The IRX1 automatically monitors any ITX1 and ITX2 that match its parameters and are transmitting in the return path of the nodes linked to it NOTE The return path of the nodes in areas where you are measuring ingress must be connected to the inputs of an IRX1 There are a total of 32 inputs per IRX1 Depending on the operator s signal sensitivity needs it is possible to combine up to 8 nodes per input 4 2 ITX2 setup The ITX2 is ready to operate as a mobile unit to locate ingress right out of the box requiring only that you connect an antenna and power it on The operating parameters and keypad functions are described in the Operation section of this manual 14 CPAT FLEX ITX2 effigis com 5 Operation 5 1 LCD information At startup the LCD display shows a splash screen with the Effigis logo for about 3 seconds Then the main interface appears summarizing the unit s operating parameters Transmission Frequency 6 78 MHz Batt status ow Battery SiS TX HGH fp Portable Ant Dipole Antenna The LCD screen also allows you to browse through and edit the operating parameters see Menu content below 5 2 Button functions Power button Used to turn On Off the unit by pressing the button for about 1 second NOTE The ITX2 is automatically turned On Off by the ARD4 when they are linked via
18. of business hour technical assistance in warranty repair and calibration B 1 Customer Support Customer Support is accompanied with the sale of every Effigis product Customer Support services include Product and Service Literature Technical Assistance Business Hour Equipment Repair Under Warranty Repair and Calibration Services Equipment Return Authorizations Contact a Customer Support representative through your local distributor or by accessing http effigis com for information on calibration and warranty policies B 1 1 Equipment Return Instructions Please contact your local Customer Support location via telephone for Return Authorization to accompany your equipment For each piece of equipment returned for repair attach a tag that includes the following information Owner s name address and telephone number The serial number product type and model Warranty status If you are unsure of the warranty status of your instrument contact Effigis Customer Support detailed description of the problem or service requested The name and telephone number of the person to contact regarding questions about the repair The return authorization RA number If possible return the equipment using the original shipping container and material If the original container is not available the unit should be carefully packed so that it will not be damaged in transit when needed appropriate
19. omous detection 21 5 7 Replacing the Battery Pack 22 5 8 Updating the ITX2 s Firmware 23 Operation Manual 3 CRAT CONTINUOUS MONITORING SYSTEM 6 Maintenance 23 6 1 Cleaning RR sais ans God E RE EE 23 6 2 Preventative Maintenance 23 Appendix A Specifications 23 A1 TOCHIGI sain aa o ea aire ta wien ut rcc acm e aa 23 A 2 Electrical and Environmental 24 AS Physical nete qe ae lt a de 24 Appendix B Our 25 Bol Customer SUDDOIL rettet psp see entrer 25 B 1 1 Equipment Return Instructions 25 B 2 Limited Product 26 2 1 HardWate ecce Leere ede edat 26 B 2 2 SOWA E rer Rr RP ane near Rd 26 2 3 EXCIUSIONS e et eret e Rx ER E RE 26 B 2 4 Refurbished Parts and Prior Testing 26 B 2 5 Exclusive 27 2 6 DISCIalITIOI atre reir rer RR RE RERO RR 27 Installation diagram 28 4 CPAT FLEX ITX2 effigis com 1 General Information 1 1 About this Manual This manual describes the components installation and operation of the ITX2 You will
20. ow firmware updates can be performed 5 4 Using the ITX2 as a portable transmitter Once it is fully booted up the ITX2 starts to transmit using the active parameters If required adjust the power level and the antenna type to optimize ingress detection The ingress level can be accessed through a computer or a smart phone with a web browser pointing to the following link http www cpat solution com RIM Access to readings through the RIM is restricted to CPAT users Use the same username and password to log into the RIM The list of available ITX1 and ITX2 units is built using the regions or PSIDs granted to the group the username belongs to Once connected to a specific ITX the readings are updated every second If no ingress is measured at the headend from a particular ITX you will see the value In all other cases the ingress level measured at the headend will be displayed in dBmV 18 CPAT FLEX ITX2 effigis com NOTE When using a mobile device the audio feedback might not work depending on the device s operating system and browser version This is a known limitation for all web applications using audio feedback NOTE The RIM is also available as a mobile application for 05 and Android To download it connect to the Apple App store iTunes or the Android App store Google Play and download the CPAT app The first module within this app is an enhanced version of the RIM software on the web
21. packing materials can be obtained by con tacting Effigis Support Effigis is not liable for any damage that may occur during shipping The customer should clearly mark the Effigis issued RA or reference number on the outside of the package and ship it prepaid and insured to Effigis Operation Manual 25 CRAT CONTINUOUS MONITORING SYSTEM Equipment repaired or replaced under warranty will be returned at Effigis expense to Cus tomer Canada USA or Effigis representative all other countries All other non warranty repairs will be returned at Customer s expense to Customer Canada USA or Effigis representative all other countries B 2 Limited Product Warranty B 2 1 Hardware Effigis warrants to the original end user Customer that the new Effigis branded products will be free from defects in workmanship and materials under normal use for one 1 year from the date of original shipment Effigis warrants repaired products for ninety 90 days from date of shipment Any Product repaired or replaced under warranty is only warranted for the period of time remaining in the original warranty for the Product Any third party products including software included with Effigis products are not covered by this Effigis warranty and Effigis makes no representations or warranties on behalf of such third parties Any warranty on such products is from the supplier or licensor of the product B 2 2 Software Effigis warrants to the
22. re the speaker compart ment inside the unit has been intentionally left empty Operation Manual 11 CFA CONTINUOUS MONITORING SYSTEM 3 Installation 3 1 Using the Vehicle Support Bracket optional If you intend to use the ITX2 in conjunction with the it is recommended that you use the vehicle bracket to secure the device while the vehicle is moving 3 1 1 Safety Precautions for Installation 1 Never install this product in places where or in a manner that it could injure the driver or passengers if the vehicle stops suddenly 2 Never install this product in places where or in a manner that it may interfere with the driver s operation of the vehicle such as on the floor in front of the driver s seat or close to the steering wheel or shift lever 3 Make sure there is nothing behind the dashboard or paneling when drilling holes in them Be careful not to damage fuel lines brake lines electronic components communication wires or power cables When using screws do not allow them to come into contact with any electrical lead 4 To ensure proper installation use the supplied parts in the manner specified If any parts other than the ones supplied are used they may damage internal com ponents of this product or they may work loose and the product may become detached 5 It is extremely dangerous to allow the cables to become wound around the steer ing column or shift lever Be sure to install this p
23. roduct its cables and wiring in a way that does not obstruct or hinder driving 6 Make sure that leads cannot get caught in a door or the sliding mechanism of a seat resulting in a short circuit N Do not install this system where it may i obstruct the driver s vision ii impair the performance of any of the vehicle s operating systems or safety features including airbags hazard lamp buttons or iii impair the driver s ability to operate the vehicle safely Never install the system in front of or next to the place in the dash door or pil lar from which one of your vehicle s airbags would deploy Please refer to your vehicle s owner s manual for reference to the deployment area of the frontal airbags Do not install the system in a place where it will impair the performance of any of the vehicle s operating systems including airbags and headrests CPAT FLEX ITX2 effigis com 3 1 2 Installing the Vehicle Support Bracket The vehicle support bracket is designed to store the ITX2 for handy access It typically mounts on the vehicle s dash near the 12V power source so the ITX2 can remain in the sup port bracket while charging You will require 3 screws not provided to secure the bracket to the dash CAUTION Do not disconnect or modify the vehicle s safety systems such as airbags or seatbelts Safety system wires have yellow sleeves and yellow connectors Accidental triggering of thes
24. tenna type unless you are physically connecting a different antenna NOTE Effigis offers other types of antennas that can be used with the ITX2 Re gardless of the antenna you are using it is very important to make sure the ITX2 s settings match the actual antenna type connected to the unit in order to transmit at a similar level and be able to compare ingress readings Using an antenna that is not authorized by Effigis or setting up the ITX2 with the wrong antenna type will result in erroneous readings Frequency This menu displays the active test carrier signal transmission frequency Considering that it is hardware dependent and set at the factory it cannot be modified through the interface The transmission frequency can be 6 78 MHz or 27 12 MHz Operation Manual 17 CRAT CONTINUOUS MONITORING SYSTEM Backlight The ITX2 s display is backlit to facilitate reading content in various lighting condition How ever to maximize battery life it is programmed to automatically turn off after a specified period of keypad inactivity The backlight delay can be selected from one the following values always ON 10 sec de fault 30 sec 60 sec or OFF Contrast The contrast level can be adjusted in this menu by specifying a value from 1 lowest to 10 highest The default value is 6 Version This menu displays the active firmware version NOTE See section Updating the ITX2 s Firmware for information h
25. unit at room temperature Do not place the unit in a location where temperature extremes occur during charging The ITX2 is equipped with additional protection to prevent the battery from charging when its temperature is below 0 C 32 F or above 40 C 104 F 4 t is possible to charge the unit for a short period e g 15 minutes and return to using it on battery power when immediate use is required You should however fully recharge the unit at the earliest opportunity e g end of work shift IMPORTANT INFORMATION REGARDING CHARGE AND DISCHARGE The ITX2 is equipped with a protection against deeply discharged cells that allows you to charge them even if this situation occurs It is critical to note that a deep discharge reduces the lifetime of the battery pack and care must be taken to avoid this situation 5 6 Using the ITX2 for autonomous detection The ITX2 can be used for autonomous detection when used with an ARD4 the central control module of the CPAT FLEX platform To do so the ITX2 must be linked to the ARD4 using the USB cable Once connected the ARD4 will power On Off and configure the ITX2 The ITX2 will transmit as long as the ARD4 records and the GPS signal is valid The ITX2 transmission will only be used for reading via the RIM application if the vehicle s speed is below the threshold default is 5 km h If the vehicle moves faster than the threshold speed the IRX1 will also use ITX2 transmission to record ingress
26. upport Effigis Technical Support Service is available from Monday through Friday from 9 00 AM to 5 00 PM Eastern Time Toll free from U S and Canada 1 888 495 6577 International 1 514 495 0018 Fax questions anytime to 1 514 495 4191 cpat effigis com 1 5 Calibration Your ITX2 unit has been calibrated and tested in the factory and does not need further calibration before use However if the unit suffers damage and needs repair it is recommended that the unit be returned to an authorized Effigis service center where it will be properly recalibrated If your company requires regular calibration of all equipment or requires a calibration certifi cate for the ITX2 a calibration service is available through Effigis For more information on calibration services please contact your Effigis representative 1 6 Effigis Website Effigis website contains product specifications information press releases brochures downloads and Frequently Asked Questions FAQs Please visit our website at http effigis com 6 CPAT FLEX ITX2 effigis com 2 System Components The ITX2 is a portable radio transmitter that continuously transmits a low power test car rier signal in the cable upstream band to detect ingress faults It can be used as a portable find and fix tool or can be plugged into the ARD4 CPAT FLEX module to automatically locate ingress impairments while driving in the operator s territory as part of the techni