Home

Display - Service, Support

image

Contents

1. DLLROUTINE mobyErr_t DLLDECL moby diagnose MOBY API C Library 4 J31069 D0137 U001 A5 7618 char comStr int channel mobyHandle_t handle unsigned short sPort mobyHandle_t handle mobyHandle_t handle mobyType_t type BOOL eccOn mobyParameters_t param HANDLE sync mobyErr_t err mobyHandle_t handle mobyHandle_t handle mobyStatusU t stat HANDLE sync mobyErr_t err mobyHandle_t handle unsigned char mode mobyDiagnose_t diagnose HANDLE sync mobyErr_t err 115 Header Files 03 05 DLLROUTINE mobyErr_t DLLDECL moby _s_ read mobyHandle t handle uInt idData uInt mdsAddress unsigned char data uInt length HANDLE sync mobyErr_t err DLLROUTINE mobyErr_t DLLDECL moby _s_getID mobyHandle t handle mobyMtget_t getInfo int address uInt length HANDLE sync mobyErr t err DLLROUTINE mobyErr_t DLLDECL moby_s_ write mobyHandle t handle uInt idData uInt mdsAddress unsigned char data uInt length HANDLE sync mobyErr_t err DLLROUTINE mobyErr_t DLLDECL moby _s_ init mobyHandle t handle uInt idData unsigned char setVal uInt mdsLength HANDLE sync mobyErr _t err DLLROUTINE mobyErr_t DLLDECL moby _unexpect mobyHandle t handle moby UnexpCallback_t cbroutine DLLROUTINE mobyErr_t DLLDECL moby _anw mobyHandle_t handle moby AnwCallback_t cbroutine DLLROUTINE mobyErr_t DLLDECL moby version i
2. CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Status ERR_LED indicator ANW Data memory in field Busy Command being processed Res 00 Hex n reserve MOBY API C Library 132 4 J31069 D0137 U001 A5 7618 03 05 Description of Communication to the ASM 424 724 824 with 3964R Protocol A 6 7 NEXT Command Byte 0 1 2 3 Cen 02 o7 00 CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Acknowledgment Byte 0 1 2 3 CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Status MOBY status MOBY API C Library 4 J31069 D0137 U001 A5 7618 133 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05 A 7 MOBY F Special Features in Read Only Mode Only ASM 824 SLA 81 with MDS F1xx The RESET STATUS and READ commands are only permitted in a certain format for read only use As with READ WRITE operation only one command is possible at a time but RESET and STATUS can always be issued After a startup and RESET command all data memories are read and stored in the telegram buffer maximum of 50 telegrams if not already fetched with a READ command When the buffer is full all other data memories are ignored The last telegram contains an error message When a new data memory with different data is read the next telegram can be fetched from the ASM Command READ Command to trigger send of ASM 824 Byte 0 1 2 3 4 5 6 CHN 05 50 00 00 00 05 CHN 01
3. The screen Select Installation Folder appears with the standard setting C Program Files MOBY API This setting can be accepted with Next The setting can be changed in the Folder box or an existing directory can be selected with the Browse box see figure 2 17 The setting is accepted with Next and the screen Confirm Installation figure appears MOBY API C Library 4 J31069 D0137 U001 A5 7618 31 Installation 03 05 4 Selecting an existing directory i MOBY API with driver TCP IP Select Installation Folder The installer will install MOBY API with driver TCP IP in the following folder To install in this folder click Next To install to a different new or existing folder enter one below or click Browse Folder C Program Files MOBY APIS Browse xi Browse Ek MOBY API a al You can install the software Volume Folder C Program Files MOBY APIS Cancel Figure 2 17 Selection of an existing directory link to Ethernet An existing directory can be selected in the screen Browse for Folder and accepted and changed in the Folder box e Press the OK button to return to the Select Installation Folder screen with acceptance of the directory e Press the Cancel button to return and cancel your selection MOBY API C Library 32 4 J31069 D0137 U001 A5 7618 03 05 Installation 5 Executing the installation of the MOBY API software i MOBY API with d
4. YHDUMPWNHFOCO Vie AREA Cae RSE E CREE CUE ESS ee eS eee ES eS Bee eee ei Constants for specific moby types define MOBY CHANNEL PARAM RESET o o o OAT PITE PIETET EEE SE EN Be oh os es ed E ae working modes for channeled ASMs general define MOBY CHANNEL ALL RESETPARAM MODE IGNORE 0x0 all ASMs for MOBY F define MOBY CHANNEL F RESETPARAM MODE MDS F1xx OxA ASM 424 824 define MOBY CHANNEL F RESETPARAM MODE MDS F4xx OxB ASM 424 824 define MOBY CHANNEL F RESETPARAM MODE MDS F2xx OxC ASM 424 for MOBY I define MOBY CHANNEL I RESETPARAM MODE 0x1 ASM 424 define MOBY CHANNEL I RESETPARAM MODE MDS507 0x4 ASM 424 for MOBY V define MOBY CHANNEL V_RESETPARAM MODE 0x9 ASM 424 for MOBY E define MOBY CHANNEL E RESETPARAM MODE 0x1 ASM 724 for MOBY U define MOBY U_ DIAG LASTCALL 0x02 define MOBY U_ DIAG LASTERR 0x03 define MOBY U_ DIAG LASTMDS 0x04 define MOBY U DIAG LASTREPEAT 0x05 TY series G8 Oa 6 Bhs Rin WE IEG eh ay CEOS LOO EON EIEIO EAE ANW control for channeled ASMs define MOBY CHANNEL RESET PARAM ANW NO 0x0 define MOBY CHANNEL RESET PARAM ANW DETECT 0x1 define MOBY CHANNEL RESET PARAM ANW CONTROL 0x2 LALLA AALALA AAAA AAAS AALALA LU TATTLE TAT TATA LAAL AALALA Error and status numbers define MOBY DLL FEHLER 0x80000000 define SET MOBY ERROR block fehler MOBY DLL FEHLER block fehler
5. typedef union mobyDiagnose d mobyDiagnoseCall _t diagCall mobyDiagnoseErr t diagErr mobyDiagnoseMDS t diagMDS mobyDiagnoseRepeat_t diagRepeat mobyDiagnose t typedef struct mobyUreset_d unsigned char standby unsigned char param unsigned char option1 unsigned char dili unsigned short mtag unsigned char fcon unsigned char ftim mobyUreset t typedef union mobyParameters d mobyUreset_t mobyParameters t Ureset A earch a saat Moh oh Teoh te Mi Soe sek 5 o s Aa Ta TUR tos Satan So Stars on Stan ee structure for multitag GET define MOBY MTGET MAXMDS 12 define MOBY MTGET MAXDATA 250 typedef struct mobyMtget_data_d uInt mds unsigned char data MOBY MTGET_ MAXDATA mobyMtget data t typedef struct mobyMtget_d int numMds mobyMtget_data_t mobyMtget_data MOBY MTGET MAXMDS mobyMtget_t typedef void CALLBACK moby UnexpCallback_t typedef void CALLBACK moby AnwCallback_t unsigned char chi unsigned char ch2 unsigned char ch3 int laenge unsigned char anwstatus LLLLLTLTLLTLTALLT TTT ALT T LATTA TAT TTT ATT TATA TTT TTT ATT TAT TT Interface of the MOBY API if defined __ cplusplus extern C endif DLLROUTINE mobyErr_t DLLDECL moby open DLLROUTINE mobyErr_t DLLDECL moby close DLLROUTINE mobyErr_ t DLLDECL moby start o ROUTINE mobyErr_t DLLDECL moby_stop DLLROUTINE mobyErr_t DLLDECL moby _statusU
6. mobyStatus_t structure Table 3 2 Structure parameters of MOBY status structure Parameter Variable weaning d error Error identifier 1 Error errorCode gt 0 0 No error dummy Area in reserve bits busyASM MDS command on ASM active no MDS command on ASM active corresponds to bit 0 in ANW Busy byte 1 MDS command on ASM active 0 No MDS command on ASM active anwMDS The presence message corresponds to bit 1 in the ANW Busy byte It indicates whether an MDS is located in the field of the SLG SLA 0 No MDS in the field 1 MDS in the field MOBY API C Library 98 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library batMDS The battery voltage status corresponds to bit 7 of the status byte battery 1 It indicates the status of the dialog battery on the MDS 1 Battery on MDS has dropped below threshold value This bit is always set for MDS types with EEPROM memory diagBatMDS507 The dialog battery status on the MDS corresponds to bit 6 of the status byte battery 2 It only applies to MDS 507 407 E 1 Battery under threshold value With other MDSs the bit can be 0 or 1 eccDone The ECC offset status corresponds to bit 5 of the status byte It only applies when with ECC offset was specified for the moby_start system function 1 ECC offset was performed The data in the result telegram are okay errorCode The MOBY error code corresponds to bits 0 to 4 in the MOBY st
7. MOBY API C Library 14 4 J31069 D0137 U001 A5 7618 03 05 Installation 3 Select directory for the C library MOBY API Select Installation Folder C Programme Mobyware Figure 2 2 Selecting directory for installation serial link to PC The screen Select Installation Folder appears with the standard setting C Programme mobyware Press Next to accept this setting Use the Folder field to change the directory or the Browse field to select an existing one see figure 2 3 Next accepts the setting and the screen Confirm Installation appears see figure 2 4 MOBY API C Library 4 J31069 D0137 U001 A5 7618 15 Installation 03 05 4 Select an existing directory Select Installation Folder C Programme Mobyware C Programme Mobyware Figure 2 3 Selecting existing directory serial link to PC You can select an existing directory in the Browse for Folder screen An existing directory can be accepted or changed in the Folder field e OK returns you to the Select Installation Folder screen with the acceptance of the directory e Cancel also returns you Your selection is cancelled MOBY API C Library 16 4 J31069 D0137 U001 A5 7618 03 05 Installation 5 Execute installation of MOBY API software i Moby API with driver 3964R Confirm Installation The installer is ready to install Moby API with driver 3964R on your
8. Table A 2 List of the commands Command Description NEXT NEXT command The SLG has finished processing the command for the MDS in its field The next MDS entering the field is processed with command started after NEXT Prerequisite presence control is activated Notice ECC mode can only be used with MOBY with the ASM 424 General telegram layout Byte Telegram header 0 1 2 3 E eee n CHN AB Command Stat Command specific data t The command specific data are discussed on the next few pages Max data length is 237 bytes Status byte The status byte must always be 00 for command output Commands The implemented commands are shown on the next few pages Number of bytes Amount of user data in telegram no of characters without AB byte und CHN Minimum AB 2 Maximum AB 239 depends on length of specified data blocks in command Channel number CHN The channel i e the read write device SLG or the read write antenna SLA is coded on the ASM with byte 0 CHN in the telegram Channel number 0 Basic module of ASM Channel number 1 2 3 or 4 SLG 1 SLA 1 to SLG 4 SLA 4 MOBY API C Library 126 4 J31069 D0137 U001 A5 7618 03 05 Description of Communication to the ASM 424 724 824 with 3964R Protocol A 6 Telegram Layout of the Commands Acknowledgments to from the ASM The maximum length of the telegram is 241 bytes including the 7 byte telegram
9. ifndef MOBY API _T H MOBYAPIDEFINED define MOBY APTI aT _H MOBYAPIDEFINED eI LILLIE A AN LICE Includes include lt windows h gt include lt winsock h gt De esc gt MO A CIIAEES Im and Export definitions for prototypes ifdef DLLROUTINE undef DLLROUTINE endif ifdef DLLDECL undef DLLDECL endif ifdef MOBY DLL IMPL define DLLROUTINE _ declspec dllexport else define DLLROUTINE _ declspec dllimport endif define DLLDECL WINAPI TILTLLTTLTLLTTI TITTLE ATTA TTA TTA TTA TTA TAT ATT ATTA TAT ATT ATA TT Type definitions O REEE AREER REET PERE IEE EEPE PELE VEEE EEE OR ETE MELE PNET PEE SP AOE general definitions typedef unsigned int mobyHandle t typedef unsigned int uInt typedef int mobyType t Pf echo ne tied og EEEE ok RANE SNE A EAE A OS ORES PLES REA ORUS HES PETS CRESS error and status type typedef struct mobyStatus_d unsigned int errorCode 5 unsigned int eccDone 1 unsigned int diagBatMDS507 1 unsigned int batMDS 1 unsigned int anwMDS 1 unsigned int busyASM Peaks kes unsigned int dummy 21 unsigned int error 1 mobyStatus t typedef struct mobyStatusU_d mobyStatus_t status unsigned char s_info unsigned char hw_type unsigned short int hw_ver unsigned short int boot_ver unsigned char fw_type unsigned short int fw_ver MOBY API C Library 4 J31069 D0137 U001 A5 7618 113 Header Files 03 05 unsign
10. void main int err2 major minor mobyErr t err merr2 unsigned char buf 300 request the version err moby version amp major amp minor printf Moby DLL Version 1i i n major minor open COM interface printf Open n adapt the line below to open other interface and to use other channels err moby_ open COM2 MOBY_CHANNEL4 amp comdev1 Tf err moby_ open COM3 MOBY NOCHANNEL amp comdev1 do reset start printf done now doing start after open returned with x n err error err error MOBY_ reset comdev1 NULL printf done n MOBY API C Library 4 J31069 D0137 U001 A5 7618 119 Sample Application 03 05 ifdef else ifdef else endif endif 120 printf Opened devicel x with error x n comdevl err error register callback for reset telegramms moby _unexpect comdev1 unex_cb read printf Read Nr length i 4 USE_MDS Flxx err2 MOBY_ read comdev1 amp buf 0 5 NULL USE_MOBY_E err2 MOBY_ read comdev1 amp buf 0 4 NULL err2 MOBY_ read comdev1 amp buf 64 4 NULL printf Result x 02x 02x 02x 02x n err2 buf 0 buf 1 buf 2 buf 3 stop merr2 moby_ stop comdev1 printf Stop x n merr2 error close merr2 moby_ close comdev1 printf Close x n merr2 error MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Sample Application 5 2 Sample A
11. HANDLE Handle to synchronization with the response telegram Initialized Windows event which the application uses to wait for the response telegram mobyErr_t Pointer to a structure in which the status byte and any error code and interface errors are to be stored See chapte Return value gt 0 No error command executed lt 0 Interface error See chapter Notice The command with mode 0 may only be sent when a command is queued for execution e g moby_read 1 In preparation 60 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 3 8 Function moby_ status mobyErr_t moby_status mobyHandle_t handle mobyStatus_t status HANDLE sync mobyErr_t err This function is used to query the status of an SLG or SLA on an ASM or SIM handle mobyHandle_t Handle of the serial interface and the channel number status mobyStatus_t Pointer to the structure in which the read status information is to be stored sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes e errors is to be stored see 372 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice Only one waiting status telegram is permitted Status queries which are sent w
12. mobyChannelasm param t typedef struct mobyChannelasm_opt_f d unsigned char resi 1 unsigned char clear_led 1 unsigned char timeout 1 unsigned char tst_on 1 unsigned char res2 1 unsigned char res3 1 unsigned char res4 1 unsigned char res5 1 mobyChannelasm_opt_f t typedef union mobyChannelasm_opt_d unsigned char raw mobyChannelasm_opt_f t fields mobyChannelasm_opt_t typedef struct mobyChannelasm_d mobyChannelasm_abta_t abta mobyChannelasm_param_t param mobyChannelasm_opt_t opt mobyChannelasm t MOBY API C Library 4 J31069 D0137 U001 A5 7618 105 Header Files 03 05 typedef struct mobyUreset_d char char char char short char char unsigned unsigned unsigned unsigned unsigned unsigned unsigned mobyUreset t standby param option1 dili mtag fcon ftim typedef union mobyParameters_d mobyChannelasm_t channelasm mobyReset_t extended mobyInterval_t interval mobyUreset_t Ureset mobyParameters t VE Soe oi EEE CIEE Strat sce es each aca ek eset sch ek ace oe structure for multitag GET define MOBY MTGET MAXMDS 12 define MOBY MTGET MAXDATA 250 typedef struct mobyMtget_data_d uInt mds unsigned char data MOBY MTGET_ MAXDATA mobyMtget_ data t typedef struct mobyMtget_d int numMds mobyMtget_data_t mobyMtget_data MOBY MTGET MAXMDS mobyMtget_t AY areas akon as ig E a Be sa Oe teed ine as a Wen ee case A eae ea gh at art
13. DLLROUTINE comInt DLLDECL ComWrite comHandle_t com_handle void FAR write_data int write number long option DLLROUTINE comInt DLLDECL ComEnableEvent comHandle_t com_handle int com_event int user_id int msg DLLROUTINE comInt DLLDECL ComDisableEvent comHandle_t com_handle int com_event DLLROUTINE comInt DLLDECL ComGetNotify WPARAM wParam LPARAM 1Param int FAR user_id ptr int FAR event_ptr int FAR state_ ptr int FAR handle ptr MOBY API C Library 110 4 J31069 D0137 U001 A5 7618 03 05 Header Files DLLROUTINE comInt DLLDECL ComClose comHandle_t com_handle DLLROUTINE comInt DLLDECL ComGetVersion char FAR ver_ string DLLROUTINE comInt DLLDECL ComString char FAR errs comInt error comInt typ D iLROUTINE comInt DLLDECL ComGetReadState comHandle_t com_handle DLLROUTINE comInt DLLDECL ComGetWriteState comHandle _t com_handle New extension to the API beyond the old ECCOM interface ate gt configuration gt option to use callback based event handler instead of Windows messages DLLROUTINE comInt DLLDECL ComReadConfig LPCSTR devName devConfig _p conf DLLROUTINE comInt DLLDECL ComWriteConfig LPCSTR devName devConfig _p conf BOOL force DLLROUTINE comInt DLLDECL ComSetNotification comHandle_t com_handle comNotifCall p_ callback int userID if defined __ cplusplus endi
14. MOBY API C Library 4 J31069 D0137 U001 A5 7618 Diagnostic information Telegram length in bytes without AB byte Variable telegram length in bytes without AB byte depending on the variable length of the user data 163 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 3 2 1 B 3 2 1 1 B 3 2 1 2 B 3 2 1 3 B 3 2 1 4 164 Acknowledgments to MDS Functions INIT Acknowledgment See appendix B 2 2 1 1 WRITE Acknowledgment See appendix READ Acknowledgment See appendix MDS STATUS Acknowledgment Acknowledgment without error status 00 hex Byte 0 1 2 3 to 6 7 8 to 11 12 13 Parameter 12 OB Status MDS no MDS Sum of Sum of search type subframe mode accesses accesses 14 15 16 17 18 MCOD Remain batt ST Status Bit pattern 00 hex MDS no Binary value Value of 2 to 2 MDS type Binary value 84 Hex MDS with 2 Kbytes with ECC 86 Hex MDS with 32 Kbytes with ECC Sum of Binary value Sum of subframe accesses subframe 32 bits accesses Sum of Binary value Sum of search mode accesses search 16 bits Upper 16 bits of a 32 bit value indicating the mode number of search accesses before the sleep accesses time changed last MCOD Binary value Date of last time sleep time was changed 16 bits byte 14 Calendar week byte 15 Calendar year without century If the sleep time has not changed calendar week 01 an
15. The following table lists the address areas of the individual MDS models Table A 4 Address area of MDS Addressing Hexadecimal 16 Bits Fixed Point Number 16 Bits Normal With ECC Normal With ECC MOBY 62 byte data memory with RAM Start address 0000 0000 0 End address 003D 0029 61 41 MOBY 128 byte data memory with EEPROM Start address 0 End address MOBY 2 Kbyte data memory with RAM Start address End address MOBY 8 Kbyte data memory with EEPROM Start address 0000 0000 End address 1FFC 1BF1 MOBY 32 Kbyte data memory with RAM Start address 0000 0000 End address 7FEC 6FF1 32764 28657 MOBY E 752 byte data memory with EEPROM oO 8188 7153 oO oO Start address Length MOBY E 5 byte MDS F1xx Start address End address MOBY F 32 byte MDS F2xx Start address End address ID no can only be read as a whole Start address 0000 Length MOBY F 192 byte MDS F4xx EEPROM Start address End address ID no can only be read as a whole Data representation in DATDB 1st byte MSB 4th byte LSB 1 ECC mode cannot be used with MOBY E F The data memories are addressed as shown in the table MOBY API C Library 136 4 J31069 D0137 U001 A5 7618 03 05 Description of Communication to the ASM 424 724 824 with 3964R Protocol A 9 Status and Error Codes ASM 424 ASM 724 and ASM 824 Table A 5 Status and error codes of ASM 424 724 824 Error Code Flashing LED De
16. MDSno 1 addressi1 length MDS no 2 address2 MDS no 1 Binary value Value 2 to 2 1 MDS no of MDS 1 whichis to be copied Address1 Binary value 0 to maximum length of user data minus 1 Start address of the data to be copied from MDS 1 The address plus data length must be less than the end address Length Binary value Number of bytes to be copied 1 to maximum length of the data memory MDS no 2 Binary value Value 2 to 2 1 MDS no of MDS 2 to which data are to be copied Address2 Binary value 0 to maximum length of the user data minus 1 Start address on MDS 2 starting at which the data are to be written The address plus data length must be less than the end address The COPY command may only be used on the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If the two specified MDSs are not located in zone 1 the command is terminated with an error Notice The OTP memory cannot be copied with the COPY command MOBY API C Library 4 J31069 D0137 U001 A5 7618 177 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 1 1 6 MDS STATUS Function You can use this function to non specifically or specifically determine the status and diagnostic data of an MDS which is located in the antenna field of the SLG U92 e A read call is non specific when the call does not include the identification number of the MDS Only one
17. Opened devicel x with error x n comdevl err error register callback for reset telegramms moby _unexpect comdev1 unex_cb read printf Read Nr length i 4 err2 MOBY _read comdev1 amp buf 64 4 NULL printf Result x 02x 02x 02x 02x n err2 buf 0 buf 1 buf 2 buf 3 stop merr2 moby_stop comdev1 printf Stop x n merr2 error close MOBY API C Library 122 4 J31069 D0137 U001 A5 7618 03 05 Sample Application merr2 moby _close comdev1 printf Close x n merr2 error MOBY API C Library 4 J31069 D0137 U001 A5 7618 123 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05 A Description of Communication to the A 1 A 2 124 ASM 424 724 824 with 3964R Protocol This appendix is written for users who want to place their application directly on the operating system or driver level and do not want to use the MOBY API C library For more information on the 3964R driver level see also the user s manual on using the 3964R protocol under Windows NT 4 0 95 included as PDF file on the MOBY software CD General The ASM 424 724 824 interface modules use a Baud rate of 9 6 kBaud 19 2 kBaud or 38 4 kBaud The Baud rate is recognized automatically The data format consists of 1 start bit 8 data bits 1 parity bit parity supplements to give an odd total number of ones and 1 stop bit After the module is turned on st
18. Pointer to the structure in which the status and diagnostic information of the response telegram are to be stored mode unsigned char 00 hex Request status and diagnostic data of an MDS cweek unsigned char 01 to 35 hex Current calendar week 1 to 53 for determination of remaining battery life No determination of remaining battery life year unsigned char 01 to 63 hex The last two positions of the current year beginning with 01 for determination of remaining battery life No determination of remaining battery life sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram err mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 3 7 2 MOBY API C Library 4 J31069 D0137 U001 A5 7618 85 MOBY API C Library 03 05 86 Return value gt 0 No error command executed lt 0 Interface error See chapter 3 7 1 Notice The antenna must be on Otherwise an error message is generated Function sequence depends on the two fields cweek and year a If the value in both fields is within the value range the remaining battery life is output in the response b If one of the values is outside the specified value range the remaining battery life cannot be calculated and the function is terminated with an error
19. Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 2 1 2 2 B 2 1 2 3 146 SLG Status Function SLG Status Diagnosis This function is used to poll the status of the SLG U92 or to read the diagnostic data from the SLG U92 Byte 0 1 2 3 4 5 6 Parameter 06 04 00 Mode 00 00 00 Mode Binary value 01 hex SLG status 02 hex SLG diagnosis Request last n function calls 03 hex SLG diagnosis ll Request last n error messages 04 hex SLG diagnosis III Request last n identified MDSs The SLG STATUS command may always be sent to the SLG U92 and is executed immediately When a command such as READ WRITE or INIT is queued on the SLG U92 it is retained L UEB Function This function is used to monitor the connection to the SLG U92 at the logical level Byte 0 1 2 Parameter 02 FF 00 The L UEB command may always be sent to the SLG U92 and is answered immediately If no return message is received the connection to the SLG U92 is disconnected due to a malfunction When a command such as READ WRITE or INIT is queued on the SLG U92 it is retained MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 2 2 Acknowledgments Messages from the SLG U92 Telegram overview Telegram Header User Data Max of 251 Bytes 0
20. REPEAT L UEB Startup ANW MELD ABL Diagnostic information Telegram length in bytes without the AB byte Variable telegram length in bytes without the AB byte depending on the variable length of the user data MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 2 1 Acknowledgments to MDS Functions B 4 2 1 1 INIT Acknowledgment Acknowledgment without error status 00 hex Byte 0 1 2 3 to6 Parameter 06 03 status MDS no Status Bit pattern 00 hex MDS no Binary value Value 2 to 2 1 MDS no of the initialized MDS Acknowledgment with error status not equal 00 hex Byte 0 1 2 3 to6 Parameter 06 03 status MDS no Status Bit pattern For status see appendix B 6 MDS no Binary value Value 2 to 2 4 MDS no of the not initialized MDS specific initialization call with error 0 Non specific initialization call with error MOBY API C Library 4 J31069 D0137 U001 A5 7618 185 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 2 1 2 WRITE Acknowledgment Acknowledgment without error status 00 hex Byte 0 1 2 3 to6 Parameter 06 01 status MDS no Status Bit pattern 00 hex MDS no Binary value Value 2 to 2 4 MDS no of the written MDS Acknowledgment with error status n
21. The header file was developed with and for Visual C If you want to use another programming language or a C dialect from another company the header file may have to be adjusted The MOBY_API H header file requires the include file 3964R H from the 3964R driver Sample application In addition to the C library an executable sample application EXAMPLE EXE is supplied which makes it easy to get started with the implementation of a user application It is also available in source code EXAMPLE CPP It can be used as the basis of your own user application which can be fully linked in and executed 1 2 3 System Prerequisites for Serial Link to PC The following prerequisites must be met before the C library can be used under Windows e Personal computer PC AT compatible PC or PG e Operating system Windows 98 NT 4 0 2000 XP e Free serial interface s RS 232 RS 422 e Programming regulations The MOBY_API LIB interface library is written in C and is compatible with Microsoft Visual C compiler versions gt 6 0 Other programming languages e g Visual Basic with a wrapper MOBY API C Library 4 J31069 D0137 U001 A5 7618 9 Introduction 03 05 1 3 Link to Ethernet MOBY systems are linked to Ethernet with PC with Windows 98 NT 4 0 2000 XP via the ASM 480 interface module as shown in The MOBY system is connected serially to the ASM 480 The protocol between the ASM 480 and the MOBY system is always 3964R Th
22. and then WRITE command The END command may only be used on the SLG U92 after the READ WRITE or INIT command No command may be queued on the SLG U92 The antenna must be on Otherwise an error message is generated If there is a non specific call and there is more than one MDS in zone 1 or the last processed MDS has left zone 1 and mode 01 was selected the command is terminated with an error When the call is specific and the MDS with the specified MDS no is not located in zone 1 the command is terminated with an error REPEAT Function This function is used to automatically repeat an MDS command MDS function or a command chain MDS functions as soon as an MDS enters the antenna field e MDS command INIT WRITE READ and MDS STATUS The GET COPY and END commands cannot be automatically repeated e Command chain Chain of MDS commands INIT WRITE READ and MDS STATUS and the END command The END command may only be located at the end of the command chain This function repeats the MDS command last transferred or executed or the command chain last transferred or executed With the MDS command s to be executed the MDS no must be preassigned with zero No MDS no may be entered The REPEAT function is possible when e Bunch 1 is parameterized and an MDS is located in the antenna field or e Bunch gt 1 is parameterized and only one MDS is located in the antenna field MOBY API C Library 4 J31069 D0137 U001 A5 76
23. fcon Binary value ASCII Binary value Binary value ASCII format Binary value ASCII format Binary value Binary value Binary value Binary value Binary value Binary value 01 hex SLG status mode HW version HW version 00 hex to FF hex 00 hex to FF hex Bootstrap loader version 00 hex to FF hex 00 hex to FF hex FW version Version high byte Version low byte Version high byte Version low byte FW version 00 hex to FF hex 00 hex to FF hex Driver version T 3964R Driver version 00 hex to FF hex Version high byte Version low byte Version high byte 00 hex to FF hex Version low byte RS 232 RS 422 01 hex RS 422 02 hex RS 232 Baud rate 01 hex 19 2 Kbaud 02 hex 38 4 Kbaud 03 hex 57 6 Kbaud 05 hex 115 2 Kbaud Distance limit Normal sending capacity Reduced sending capacity 05 hex 0 5m 85 hex 0 5m OA hex 1 0m 8A hex 1 0m OF hex 1 5m 8F hex 1 5m 14 hex 2 0m 94 hex 2 0m 19 hex 2 5m 99 hex 2 5m 1E hex 3 0m 9E hex 3 0m 23 hex 3 5m A3 hex 3 5m Number of MDSs in the antenna field which can be processed multitag bunch 1 Proximity switch field ON control 00 hex Mode 1 Without proximity switches or SLG synchronization 01 hex Mode 2 1 or 2 prox switches The proximity switches are OR linked The field is on while the 1st and or 2nd proximity switch is on Otherwise off 02 hex Mode 3 1 or 2 pr
24. int comdev void CALLBACK status int HANDLE sync mobyErr t errl err2 mobyParameters t ResetParam unsigned int moby str This initialization should be done to avoid side effects sync CreateEvent NULL FALSE FALSE NULL Reset Param Ureset standby ResetParam Ureset param 0x00 0x26 MOBY API C Library 4 J31069 D0137 U001 A5 7618 121 Sample Application 03 05 Reset Param Ureset optionl 0x00 ResetParam Ureset dili 0x05 ResetParam Ureset mtag 0x0002 ResetParam Ureset fcon 0x00 ResetParam Ureset ftim 0x00 moby str MOBY Uc errl moby _start comdev moby str FALSE amp ResetParam sync amp err2 if errl error MOBY_OK WaitForSingleObject sync INFINITE errl error volatile int err2 error CloseHandle sync return errl error void main int err2 major minor mobyErr t err merr2 unsigned char buf 300 unsigned short port _nr 8000 define IP ADRESSE 157 163 170 2 request the version err moby _version amp major amp minor printf Moby DLL Version 1i i n major minor open COM interface printf Open n adapt the line beloew to open other interface and to use other channels err moby _open IP ADRESSE 0 amp comdev1l port_nr do reset start printf done now doing start after open returned with x n err error err error MOBY reset comdev1 NULL printf done n printf
25. 00 hex Operation without presence check 01 hex Operation with presence check see ANW MELD acknowledgment Acknowledgment with error status not equal 00 hex Byte Parameter Status 0 1 2 02 04 Status For status see appendix B 6 Bit pattern SLG STATUS Acknowledgment SLG Diagnosis l See appendix MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 3 2 2 4 SLG STATUS Acknowledgment SLG Diagnosis II See appendix B 3 2 2 5 SLG STATUS Acknowledgment SLG Diagnosis III See appendix B 3 2 2 6 SET ANT Acknowledgment Byte 0 1 2 Parameter 02 OA Status Status Bit pattern For status see appendix B 6 B 3 2 2 7 END Acknowledgment Byte 0 1 2 Parameter 02 08 Status Status Bit pattern For status see appendix B 6 B 3 2 2 8 REPEAT Acknowledgment Byte 0 1 2 Parameter 02 OD Status Status Bit pattern For status see appendix B 6 B 3 2 2 9 L UEB Acknowledgment See appendix MOBY API C Library 4 J31069 D0137 U001 A5 7618 169 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 3 2 3 Messages B 3 2 3 1 Startup Message See appendix B 3 2 3 2 ANW MELD Message See appendix MOBY API C Library Tg 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 MOBY U with Mu
26. 1 2 3 to max of 253 bytes Acknowledg User data ment message hex INIT WRITE READ Address RESET FW SLG STATUS S info Status information SLG status SLG STATUS Sinfo Diagnostic information Diagnosis l SLG STATUS Diagnostic information Diagnosis II SLG STATUS Diagnostic information Diagnosis III L UEB Startup ANW MELD Telegram length in bytes without the AB byte ABL Variable telegram length in bytes without the AB byte depends on the variable user data length B 2 2 1 Acknowledgments to MDS Functions B 2 2 1 1 INIT Acknowledgment Byte 0 1 2 Parameter 02 03 Status Status Bit pattern For status see appendix B 6 MOBY API C Library 4 J31069 D0137 U001 A5 7618 147 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 2 2 1 2 B 2 2 1 3 148 WRITE Acknowledgment Byte 0 1 2 Parameter 02 01 Status Status Bit pattern For status see appendix B 6 READ Acknowledgment Acknowledgment without error status 00 hex Byte 0 1 2 3 4 5 6 to max of 253 Parameter ABL 02 Status Address Length Data ABL Binary value 1 to 253 Telegram length in bytes without AB byte Status Bit pattern 00 hex Address Binary value 0 to value Memory length in bytes minus 1 16 FFFO hex after OTP memory is read Length Binary value 1 to 248 Length of user data read Data Binary info User data read by MDS Acknowledgment with er
27. 253 bytes Status User data hex Date 00 WRITE ABL 01 00 Address Length READ 05 02 00 Address Length MDS STATUS Mode Cweek RESET Standby Param SLG STATUS Mode 00 SET ANT Mode END Mode REPEAT Mode L UEB MOBY API C Library 4 J31069 D0137 U001 A5 7618 155 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 3 1 1 B 3 1 1 1 B 3 1 1 2 B 3 1 1 3 B 3 1 1 4 156 AB Telegram length in bytes without the AB byte ABL Variable telegram length in bytes without the AB byte depending on the length parameter gt 5 length Notice The data in the telegram overview and the following individual presentations are shown in hexadecimal hex format MDS Functions The MDS functions INIT WRITE and READ are used to read or write data from to the MDS The MDS function MDS STATUS is used to poll the status and diagnostic data of the MDS INIT Function See appendix B 2 1 1 1 WRITE Function See appendix B 2 1 1 2 READ Function See appendix B 2 1 1 3 MDS STATUS Function This function is used to obtain the status and diagnostic data of the MDS that is located in the antenna field of the SLG U92 It is an untargeted call since the MDS is not identified by the ID number Byte 0 1 2 3 4 5 Parameter 05 OB 00 Mo
28. 7 8 9 10 Parameter OA 00 00 Standby Param 00 dili 0001 fcon ftim U Bit 7 6 1514 13 2 10 Standby Binary value Standby time which the MDS is to wait after an executed MDS command This means that the MDS remains awake during this time so that it will be able to process the next command which must arrive within this standby time without delay The value does not specify the time directly Instead it gives a factor of 7 msec e g the value 10 is 10 x 7 msec 70 msec 0 No standby The MDS goes to sleep after each communication with the MDS 1 to 200 7msec to 1400 msec MOBY API C Library 4 J31069 D0137 U001 A5 7618 157 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 Parameter Bit 7 to6 Bit 5 Param Bit pattern Bit 4 Bit 3 to 0 dili Binary value 0 No presence check 1 Presence check see ANW MELD acknowledgment 0 In reserve 5 hex Mode MOBY U gt MOBY commands with expansions Distance limit zone 1 The read write range of the SLG U92 0 5 to 3 m can be limited in increments of 0 5 m With the maximum distance of 3 m 3 5 m must the parameterized as the limit Together with the range limitation the sending capacity can be reduced For reasons see the MOBY U manual for configuration installation and service Normal sending capacity 05 hex OA hex OF hex 14 hex 19 hex 1E hex 23 hex fcon Binar
29. 95 see PDF file on the Software MOBY CD 07 Notice For applications which are not based on the MOBY API C interface and are not directly based on the 3964R driver of the MOBY API C library an appropriate 3964R driver for the target hardware serial link must be used which meets the requirements of the SLG U92 For the behavior of the 3964R driver on the SLG U92 see MOBY U documentation 06 B 1 General Information on Communication of the SLG U92 MDS and system functions are available for communication with the mobile data memories MDS U313 MDS U315 MDS U524 MDS U525 and MDS U589 and for control of the system behavior of the SLG U92 Management of the data on the mobile data memories MDS U313 MDS U315 MDS U524 MDS U525 and MDS U589 uses byte addressing with absolute addresses normal addressing You can choose between three versions of the system control 1 MOBY call compatible Read write distance up to 1 5m 5 Range limited to 1 5 m fixed setting Bunch multitag 1 gt Bunch set to 1 fixed Without proximity switch operation The SLG U92 does not evaluate the digital inputs on the service interface Without SLG synchronization 2 MOBY call compatible with expanded commands Read write distance of 0 5 m up to maximum of 3 5 m can be set in increments of 0 5 m Bunch multitag 1 gt Bunch set to 1 fixed Proximity switch possible SLG synchronization pos
30. ATTA TTA ATTA TT TT Includes include lt 3964r h gt TILELLTLLLTLTTLTT ALT ATTA TTA TTA TATA TTA TTT ATTA TTT ATTA ATTA TTT Im and Export definitions for prototypes ifdef DLLROUTINE undef DLLROUTINE endif ifdef DLLDECL Hundef DLLDECL endif Hifdef MOBY DLL IMPL define DLLROUTINE _ declspec dllexport else define DLLROUTINE _ declspec dllimport endif define DLLDECL WINAPI LLTLLTLTLLTLTATLT TLL ALLL TALL ATT TAT TTT ATT TAT TAT TAT TTT ATT TTT Constants define MAXCHANNEL 4 LLTTLTLLLLLLTATLT TTT ATT LATTA TTT ATT TTT ATTA TTT TTT TTT Type definitions MOBY API C Library 102 4 J31069 D0137 U001 A5 7618 03 05 Header Files Det a he Aen lt tect ated ce hay a casas Ze general definitions typedef unsigned int mobyHandle t typedef unsigned int ulInt typedef int mobyType_t LL Rae RA EEE Bo NEE IIS EIB BLES LIE Si LET a IRL A A ES error and status type typedef struct mobyStatus_d unsigned int errorCode 5 unsigned int eccDone 1 unsigned int diagBatMDS507 Is unsigned int batMDS 1 unsigned int anwMDS 1 unsigned int busyASM 1 unsigned int dummy 21 unsigned int error 1 mobyStatus t typedef struct mobyStatusU_d mobyStatus_ t status unsigned char s_info unsigned char hw_type unsigned short int hw_ver unsigned short int boot_ver unsigned char fw_type unsigned short int fw_ver unsigned char drv_type unsigned short int dr
31. Byte 0 1 2 3 4 5 6 CHN 05 00 Status High Low Inres 1 or 0 1 2 3 CHN 02 00 Status CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Status MOBY status High Firmware status in ASCII Low Firmware status in ASCII Res 1 Reserved A 6 3 WRITE Command Byte 0 1 2 3 4 5 6 Starting with 7 CHN AB 51 00 ADRH ADRL Length Data With ECC Command 41 CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 AB Number of subsequent characters in the telegram ADRH Start address on MDS more significant portion of address ADRL Start address on MDS less significant portion of address Length Length of the data block max of 234 bytes Data Data to be written Acknowledgment Byte 0 1 2 3 CHN 02 51 Status With ECC Command 41 CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Status MOBY status MOBY API C Library 19 4 J31069 D0137 U001 A5 7618 03 05 Description of Communication to the ASM 424 724 824 with 3964R Protocol A 6 4 READ Command 4 1 2 3 4 5 COCEA Mit ECC Befehl 40 CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 ADR H Start address on MDS more significant portion of address ADRL Start address on MDS less significant portion of address Length Length of the data to be read max of 234 bytes Acknowledgment Byte 0 1 2 3 4 5 6 7 to CHN AB 50 Status ADRH ADRL Length
32. CPP in source code VC 6 0 as the basis for creating your own user application for an SLG U92 with ASM 480 It gives you an overview of the primary MOBY API functions For more information see also chapter 5 2 Both sample applications are included in the EXAMPLE ZIP file 1 3 3 System Prerequisites for Link to Ethernet Use of the C library under Windows requires the following prerequisites e Personal Computer PC AT compatible PC or PG e Operating system Windows 98 NT 4 0 2000 XP e LAN connection to PC e Programming rules The interface library MOBY_API_T LIB is written in C and is compatible with Microsoft Visual C compiler version gt 6 0 Other programming languages e g Visual Basic via a wrapper MOBY API C Library 12 4 J31069 D0137 U001 A5 7618 03 05 Installation 2 Installation 2 1 Files Supplied e mobyapi msi Windows Installer Package with C library for MOBY applications for serial linking to PC Use the Windows installation package mobyapi msi to install deinstall the C library for MOBY applications e mobyapi_t msi Windows Installer Package with C library for MOBY applications for linking to Ethernet You can use the Windows installation package mobyapi_t msi to install or de install the C library for MOBY applications e InstMsiW exe Windows Installer for Windows NT e InstMsiA exe Windows Installer for Windows 98 Notice If the Windows installation package mobyapi msi or mobya
33. If both values are specified as FF hex days the remaining battery life cannot be calculated and the battery life is indicated in the acknowledgment as FFFF hex If the MDS that is specifically called with its identification number is not located in zone 1 the command is terminated with an error If the call is non specific and no MDS is located in zone 1 an error message is generated If the call is non specific and more than one MDS is located in zone 1 the command is terminated with an error MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 14 Function moby_s_ readOTP mobyErr_tmoby_s readOTP mobyHandle_t handle ulnt idData unsigned char data HANDLE sync mobyErr_t err You can use this function to execute a one time specific or non specific read access to the OTP memory One Time Programmable with a length of 16 bytes 128 bits e A read call is specific when the call includes the identification number of the MDS More than one MDS may be located in the antenna field You can determine the identification number of the MDS with the GET function e A read call is non specific when the call does not include the identification number of the MDS Only one MDS may be located in the antenna field handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData ulnt Value from 20 to 232 1 Identification number of the MDS Wh
34. LAENGE ERR_MACRO MOBY _ERRB API 4 define MOBY ERR FULL ERR MACRO MOBY_ERRB API 5 define MOBY ERR MDSTYP ERR_ MACRO MOBY _ERRB API 6 define MOBY ERR NOHANDLE ERR_MACRO MOBY _ERRB API 7 define MOBY ERR SYSTEM ERR_ MACRO MOBY _ERRB API 8 define MOBY ERR ABORT ERR MACRO MOBY _ERRB API 9 define MOBY ERR NOID ERR_MACRO MOBY_ERRB_ API 10 define MOBY ERR _STILLOPEN ERR_MACRO MOBY ERRB API 11 define MOBY ERR _IMPLABORT ERR_MACRO MOBY _ERRB API 12 define MOBY ERR ALREADYOPEN ERR_MACRO MOBY _ERRB API 13 define MOBY ERR STARTED ERR_MACRO MOBY _ERRB API 14 define MOBY ERR _NOTSTARTED ERR_MACRO MOBY _ERRB API 15 define MOBY ERR _STATUSPENDING ERR_MACRO MOBY _ERRB API 16 define MOBY ERR _NOTSUPPORTED ERR MACRO MOBY _ERRB API 17 define MOBY ERR _WRONTIPADR ERR_MACRO MOBY _ERRB API 18 define MOBY ERR _INVALIDSOCK ERR_MACRO MOBY _ERRB API 19 define MOBY ERR CONNECT ERR_MACRO MOBY ERRB API 20 define MOBY ERR _KENNUNG ERR_MACRO MOBY _ERRB API 21 endif MOBYAPIDEFINED MOBY API C Library 4 J31069 D0137 U001 A5 7618 117 Sample Application 03 05 5 Sample Application To make it even easier to get started with the implementation of a user application we have also included a sample application in source code in addition to the C library for each type of link serial and Ethernet The sample applications can also be used as an executable program 5 1 Sample Application
35. MOBY systems Notice The non specific MDS functions can only be used via the serial interface not via the Ethernet interface The specific MDS functions are listed below moby_s read moby_s_getID moby_s write moby_s init moby_s copy moby_s_statusMDS moby_s readOTP moby_s_writeOTP MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library antenna field Multitagging is possible In addition the moby_s_copy function lets you copy data from one MDS source to another MDS destination without having to use the application The specific MDS functions i e multitag mode is possible can only be used with MOBY U With the moby_ start function the parameter type must be set to MOBY_Uc MOBY U with commands with single tag and multitag capability See table 3 1 and chapters 3 4 7 to 3 4 15 for which functions can be used with which parameterization with MOBY U Table 3 4 Assignment of the MDS functions to the interfaces Serial Interface Ethernet Interface moby_read X moby_getID moby _write moby_init moby_statusMDS moby_readOTP moby_writeOTP moby_s_read moby_s_getID moby_s_write moby_s_ init moby_s_copy moby_s_statusMDS moby_s_readOTP X XIXI XXXI X XXIX X X X X lt x X X KL X Xx Xx Xx moby_s_writeOTP MOBY API C Library 4 J31069 D0137 U001 A5 7618 67 MOBY API C Library 03 05 3 4 1 68 Function
36. No error command executed lt 0 Interface error See chapter Notice If the moby_anw function does not exist in the user program and operation with presence check is set in the RESET telegram each presence message is handled as an unexpected telegram See chapter 3 3 12 moby _unexpect function MOBY API C Library 4 J31069 D0137 U001 A5 7618 63 MOBY API C Library 03 05 3 3 11 64 Function moby_diagnose mobyErr_t moby_diagnose mobyHandle_t handle unsigned char mode mobyDiagnose_t diagnose HANDLE sync mobyErr_t err This sy is used to read the diagnostic data from the SLG Parameter mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface mode unsigned char Request last n function calls Request last n error messages Request last n identified MDSs diagnose mobyDiagnose_t Pointer to the structure in which the read diagnostic information is to be stored sync HANDLE Handle to synchronization with the response telegram Initialized Windows event which the application uses to wait for the response telegram err mobyErr_t Pointer to a structure in which the status byte and any error code and_interface errors are to be stored See chapte Return value gt 0 No error command executed lt 0 Interface error See chapter Notice Only one unanswered diagnostic telegram is permitted at a time Any diagnostic query which is sent when an unanswered diagnostic query
37. TCP IP Interface module Channel number Digital inputs Digital outputs Error Correction Code Identification Internet Protocol Mobile data memory Negative Acknowledge Personal Computer Serial Interface Module Read write antenna Read write device Software Transmission Control Protocol Internet Protocol D 2 List of Literature 01 02 03 04 05 06 07 MOBY API C Library ASM 420 Interface Module Technical Description 6GT2 097 3AF00 0DA2 SIM Serial Interface Module Technical Description 6GT2 097 3AD00 0DA2 MOBY F Manual on Configuration Installation and Service 6GT2 497 4BA00 0EA2 MOBY E Manual on Configuration Installation and Service 6GT2 397 4BA00 0EA2 MOBY Manual on Configuration Installation and Service 6GT2 097 4BA00 0EA2 MOBY U Manual on Configuration Installation and Service 6GT2 597 4BA00 0EA2 MOBY user s guide 3964R protocol under Windows NT 4 0 95 Included on the MOBY Software floppy disk 4 J31069 D0137 U001 A5 7618 199 Terms Abbreviations List of Literature 03 05 MOBY API C Library 209 4 J31069 D0137 U001 A5 7618
38. Uc 7 MOBY U with multitag support LLLLLTLTLLTLT ALLL TTT ALT TT ATLL ATT TATA TAT TATA TTTATT TA TT TA TT AT TA T TT Constants for specific moby types define MOBY CHANNEL PARAM RESET o o o 1h OO ER Eee OE PIER ERT SRN OES a ORE COIR ER ORR RE AS Cee SEE PORE Oe working modes for channeled ASMs general define MOBY CHANNEL ALL RESETPARAM MODE IGNORE 0x0 all ASMs MOBY API C Library 116 4 J31069 D0137 U001 A5 7618 03 05 Header Files for MOBY U define MOBY U_ DIAG LASTCALL 0x02 define MOBY U DIAG LASTERR 0x03 define MOBY _U_ DIAG LASTMDS 0x04 define MOBY U DIAG LASTREPEAT 0x05 VA BK Sb BoRaci oe boa Boa BBE Na BI BRIS la BT DR BI BFE LTR BIR Eo BIR Ro Ib RS ANW control for channeled ASMs a A AE WEN GEREN GE ACCC C SUC Ce TCG CECE CeCe ECE CC CEE Cee ce ce seat ce Error and status numbers define MOBY DLL FEHLER 0x80000000 define SET MOBY ERROR block fehler MOBY DLL FEHLER block fehler define MOBY OK 0x0000 define MOBY ERRB API 0x10000 define MOBY ERRB TREIBER 0x20000 define MOBY ERRB ASM 0x30000 define ERR_MACRO block nummer long MOBY_DLL FEHLER block nummer API error numbers define MOBY ERR_FATAL ERR_MACRO MOBY_ERRB API 0 define MOBY ERR HANDLE ERR_MACRO MOBY_ERRB API 1 define MOBY ERR PARAM ERR MACRO MOBY _ERRB API 2 define MOBY ERR RESPONSE ERR_ MACRO MOBY _ERRB API 3 define MOBY ERR
39. be read on the MDS The address plus data length must be less than the end address 16 FFFO hex Start address of the OTP memory Length Binary value 1 to x Length of the user data to be read x 242 4 bunch size bunch size 16 Length of the OTP memory The GET command can only be used on the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If there are more MDSs in zone 1 than are permitted by the bunch parameter in the RESET telegram the number of MDSs are reported without ID numbers in an error message The reported MDSs can then not be processed Notice The 128 bits of user information in the OTP memory are addressed with start address 16 FFFO hex The 128 bits of user information are written to the MDS with the WRITE command A GET call must include all 128 bits of user information MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 1 1 5 COPY Function You can use the COPY function to specifically copy the following data from one MDS to another e A data area or e The complete contents of a data carrier This function can be used to write i e copy data directly via the user program from one MDS as the source to another MDS as the destination Byte 0 1 2 3 bis 6 7 8 9 10 11bisi14 15 16 Parameter 10 OC 00
40. can also be chained together The commands of the command chain are identified by a bit in the upper 4 bits of the command byte 2nd byte byte 1 Bit 6 is set to 1 and bits 4 5 and 7 must be 0 In the last command in the command chain bit 6 must equal 0 This signals the end of the chain The lower 4 bits of the command byte contain the function ID This means that all the commands that are chained together must have the command type 4x hex The last command in a chain must have type 0x hex The command chain can already be sent to the SLG U92 before the MDS to be processed is located in the field of the SLG U92 As soon as the MDS enters the field and is detected by the SLG U92 the SLG begins executing the chained commands and returns the acknowledgments with data If the processing of the command chain can already be started while the command chain is being sent to the SLG U92 the first acknowledgments may arrive during the sending procedure Notice The maximum length of a command chain may not exceed 150 commands Possible chaining variations a nx WRITE b nx READ MDS commands in any order INIT WRITE READ and or MDS STATUS MDS commands in any order a b or c plus END command c d e f SET ANT EIN plus followed by versions a b c or d g Versions a b c d e or f plus SET ANT AUS RESET command followed by versions a b c or d MOBY API C Library 4 J31069 D0137 U001 A5
41. computer Click Next to start the installation Cancel Previous Figure 2 4 Executing installation serial link to PC Press Next to store the MOBY API software for the creation of applications under the following subdirectories within the selected directory example example cpp Sample application in source code example exe Sample application as executable program include 3964R H Include file of 3964R driver for MOBY_API H header file MOBY_API H Header file for user applications lib MOBY_API LIB C library for user applications The DLL of the 3964R driver and the DLL MOBY_API and the CPL3964R CPL configuration program are copied to the following directory based on the Windows system e Windows NT 4 0 C AWINNT SYSTEM32 e Windows 98 C WIN98 SYSTEM e Windows 2000 C AWIN2000 SYSTEM32 e Windows XP C AWINNT SYSTEM32 The 3964R driver must be configured before the sample application can be used or a user application can be tested see chapter Zo The driver DLL contains information on existing interfaces and their configuration using the Windows registry The entries in the registry for use of the 3964R driver are generated automatically during installation MOBY API C Library 4 J31069 D0137 U001 A5 7618 17 Installation 03 05 6 Installation of the existing MOBY API C library is complete i Moby API with driver 3964R Installation Complete ence EFEVIGUS Figure 2 5 Installation completed ser
42. data from to the MDS INIT Function The INIT function is used to initialize with a bit pattern the MDS which is located in the antenna field of the SLG U92 It is an untargeted initialization call since the MDS is not identified with the ID number Byte 0 1 2 3 4 5 6 Parameter 06 03 00 Date 00 Length Date Binary value Bit pattern 00 hex up to FF hex with which the data carrier is to be initialized written Length Binary value 32768 Length in bytes of the data memory MDS U524 MDS U525 and MDS U589 2048 Length in bytes of the MDS U313 and MDS U315 data memory The INIT command may only be used for the SLG U92 and only when no command is queued on the SLG U92 The antenna must be on Otherwise an error message is generated When more than one MDS is located in zone 1 the command is terminated with an error When no MDS is located in zone 1 the command waits until an MDS enters zone 1 or the RESET command arrives MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 2 1 1 2 WRITE Function The WRITE function is used to write data to the MDS which is located in the antenna field of the SLG U92 It is an untargeted write call since the MDS is not identified by the ID number Byte 0 1 2 3 4 5 6 Up to 253 Parameter ABL 01 00 Address Length Data ABL Binary value 1 to 253 Telegram length in bytes wi
43. define MOBY OK 0x0000 MOBY API C Library 108 4 J31069 D0137 U001 A5 7618 03 05 Header Files define MOBY ERRB API 0x10000 define MOBY ERRB TREIBER 0x20000 define MOBY ERRB ASM 0x30000 define ERR_MACRO block nummer long MOBY DLL FEHLER block nummer API error numbers define MOBY ERR FATAL ERR_MACRO MOBY_ERRB API 0 define MOBY ERR HANDLE ERR MACRO MOBY _ERRB API 1 define MOBY ERR PARAM ERR MACRO MOBY ERRB API 2 define MOBY ERR RESPONSE ERR_MACRO MOBY _ERRB API 3 define MOBY ERR LAENGE ERR MACRO MOBY ERRB API 4 define MOBY ERR FULL ERR MACRO MOBY _ERRB API 5 define MOBY_ERR_MDSTYP ERR_MACRO MOBY_ERRB_API 6 define MOBY _ERR_NOHANDLE ERR MACRO MOBY _ERRB API 7 define MOBY ERR SYSTEM ERR MACRO MOBY _ERRB API 8 define MOBY ERR ABORT ERR_MACRO MOBY_ERRB API 9 define MOBY ERR NOID ERR MACRO MOBY _ERRB_ AP 10 define MOBY _ERR_STILLOPEN ERR_MACRO MOBY_ERRB_API 11 define MOBY _ERR_IMPLABORT ERR_MACRO MOBY _ERRB API 12 define MOBY ERR ALREADYOPEN ERR_MACRO MOBY _ERRB API 13 define MOBY ERR STARTED ERR_MACRO MOBY ERRB API 14 define MOBY ERR _NOTSTARTED ERR_MACRO MOBY _ERRB API 15 define MOBY ERR _STATUSPENDING ERR_MACRO MOBY _ERRB API 16 define MOBY ERR _NOTSUPPORTED ERR MACRO MOBY _ERRB API 17 endif MOBYAPIDEFINED MOBY API C Library 4 J31069 D0137 U001 A5 7618 109 Header Files 03 05 4 2 Head
44. for serial link to PC e MOBY_API_T LIB for link to Ethernet C library functions are divided into the following four function groups e Interface functions e System functions e MDS functions e DI DO functions In addition the moby_version function is available to determine the version of the dynamic link library MOBY_API DLL or MOBY_API_T DLL The following table lists the functions and their use with SLG ASM SIM Table 3 1 Use of the library functions with SLG ASM SIM Function ASM 724 ASM 824 ASM 424 ASM 420 SLG ASM 480 with with U92 SLG SLG SLG SLG 7X 4x 7x 4x System functions semitons ooo o o mobystat x x tx o bk o bk bk kbp Jmoby stop x fx fx o bk x fx dkh h moyn x f k kb k k kb bh moye fe o moys e f fe ee mobysetaNT fe jmobyrepeat f tt mobyanw bh ee jmoby status x fx o bk b bk k kb b moby_stausu j o o b o bh bh ee moby_diagnose h b bh b b bbp 1 In preparation MOBY API C Library 4 J31069 D0137 U001 A5 7618 43 MOBY API C Library 03 05 Table 3 1 Use of the library functions with SLG ASM SIM Function SLG ASM 480 ee statusMDS mabye s_copy ee eal foe e ae el mose ed mosmor gt gt E e kx _ DI DO functions moe i moby weteoa e x x x Version scan The system MDS and DI DO functions generate telegrams to the SLG ASM or SIM and always expect a response telegram from the SLG ASM or SIM However they
45. in Source Code for Serial Link to PC The sample application is an executable program for the SLA 81 on the ASM 824 as READ system with MDS F4xx The ASM 824 must be run on the COM2 interface and the SLA 81 must use channel 4 of the ASM 824 In addition the source code of this sample application can be used as the READ system for SLA 81 on ASM 824 with MDS F1xx or SLA 71 on ASM 724 by adding the appropriate define instruction Example code for MOBY API Simple open start read stop close stop sequence include lt stdlib h gt include lt stdio h gt include lt windows h gt include lt moby_api h gt mobyHandle _t comdev1 typedef DWORD MDS address typedef unsigned char zeichen default test MOBY F and MDS F4xx enable the next line to test with MOBY E define USE MOBY E enable the next line to test with MOBY F and MDS F1xx define USE _MDS F1xx callback routine for unexpected telegrams we don t expect any gt i e error gt i e stop communication void __stdcall unex_cb unsigned char cl unsigned char c2 unsigned char c3 int len printf Got unexpected telegramm n moby _stop comdev1 start and synchronize read request int MOBY_read int comdev FAR void data MDS address MDS int length void CALLBACK status int HANDLE sync mobyErr t errl err2 sync CreateEvent NULL FALSE FALSE NULL errl moby_read comdev MDS zeichen data length sync
46. in the processing list and in the presence list HANDLE Handle for synchronization with the response telegram Initialized Window event which the application uses to wait for the response telegram mobyErr_t Pointer to the structure in which the status byte is to be stored with possible _error code and interface error See chapte 3 7 2 MOBY API C Library 4 J31069 D0137 U001 A5 7618 57 MOBY API C Library 03 05 58 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice The moby_s_end command may only be sent to the SLG after the command moby_s_ write moby_s read moby_s_ init or moby_s_statusMDS and no command may be queued yet on the SLG The antenna must be on If not an error message is generated If the MDS that is specifically called with the specified ID number is not in zone 1 the command is terminated with an error If the MDS has already left the field of the SLG and mode 0 was selected an error message is generated If however another MDS has entered the field of the SLG and mode 01 was selected an error message is also generated If more than one MDS is located in zone 1 and a non specific call occurs the command is terminated with an error MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 3 6 Function moby_setANT mobyErr_t moby_setANT mobyHandle_t handle unsigned char mode mobyErr_t err This function i
47. not equal 00 hex Byte 0 1 2 3 to6 Parameter 06 08 status MDS no Status Bit pattern For status see appendix B 6 MDS no Binary value Value 2 to 2 4 MDSno specific call with error 0 MDS no not processed non specific call with error B 4 2 2 8 REPEAT Acknowledgment See appendix MOBY API C Library 4 J31069 D0137 U001 A5 7618 191 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 2 2 9 L UEB Acknowledgment See appendix B 4 2 3 Messages B 4 2 3 1 Startup Message See appendix B 4 2 3 2 ANW MELD Message See appendix MOBY API C Library 192 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 5 Command Chaining Command chaining can be used to speed up processing of large and or different address areas on the MDS Normally the SLG U92 stores only one MDS command in its memory and executes this command This means that a maximum of 248 bytes without multitagging or 244 bytes with multitagging can be read or written with one command Another command cannot be issued until the previous command is acknowledged To speed up reading or writing more than 248 bytes without multitagging 244 bytes with multitagging and or different address areas several commands can be chained and sent to the SLG U92 and stored on the SLG U92 For processing large and or different data areas different functions
48. number of the MDS When there is only one MDS in the field and a non specific write call is to be made mdsAddress_ ulnt Start address on the MDS for the data to be written 20 0 to maximum length of the user data minus 1 The address plus data length must be less than the end address on the MDS unsigned char Pointer to the buffer in which the data to be written are to be stored ulnt Number of bytes to be written gt 0 1 to maximum of 244 bytes HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapte 3721 Return value gt 0 No error command executed lt 0 Interface error See chapter MOBY API C Library 4 J31069 D0137 U001 A5 7618 79 MOBY API C Library 03 05 80 Notice The MOBY_s_write command may only be sent to the SLG U92 when no command is queued yet on the SLG U92 The antenna must be on Otherwise an error message is generated The command is terminated with an error if the MDS with the specified identification number that is specifically called is not located in zone 1 If no MDS is located in zone 1 and a non specific call occurs the command waits until an MDS moves into zone 1 or the RESET command arrives If there is more than o
49. or the Ethernet interface cbroutine moby_UnexpCallback_t Callback routine for unexpected telegrams from SLG ASM or SIM Return value gt 0 No error command executed lt 0 Interface error See chapter Notice Unexpected telegrams which can clearly be interpreted as error messages e g occurrence of an invalid telegram are evaluated as errors and handled as described in chapter 3 1 4 MOBY API C Library 4 J31069 D0137 U001 A5 7618 65 MOBY API C Library 03 05 3 4 66 MDS Functions MOBY API offers MDS functions in two versions e Non specific MDS functions e Specific MDS functions The non specific MDS functions are listed below moby_read moby_getID moby_write moby_init moby_statusMDS moby_readOTP moby _writeOTP These functions can be used to read data from any MDS or write data to any MDS Since you cannot call a specific MDS only one MDS may be located in the field of the antenna at the time the function is called and executed Multitagging is not possible These functions are executed based on the eccON parameter with or without ECC offset specified in the moby_start function See chapter 3 3 1 See documentation 01 to 06 or also appendix A 8 for ASM 424 724 824 for which address areas on the MDS can be read and written by the individual MOBY systems See table 3 1 and chapters 3 4 1 to 3 4 6 for which functions can be used with which parameterizations with the
50. sync mobyErr t err MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Header Files DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE DLLROUTINE mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t mobyErr t DLL DLL DEC DEC DECL Li DEC DEC DEC DEC DECL DEC DLL DLL DLL DLL DLL DLL DECL DECI DEC DECI Li DECL DECL DECL DECL DECL Li Li DLLDECL DLL DLL DLL if defined __ cplusplus endif DEC DEC DEC Li Li Li DECL DECL moby_read moby_s_read moby_getID moby_s_getID moby write moby _s_ write moby init moby _s_ init moby _readDE moby _writeDA moby _unexpect moby_anw moby version moby _end moby_s_ end moby repeat moby _setANT moby _statusMDS mobyHandle_t handle uInt mdsAddress unsign
51. the MDS leaves the field of the SLG There is a pause in MDS processing and the parameterized standby time is to be deactivated The MDS has not yet departed the field of the SLG Communication with the MDS will take place at least one more time The SLG keeps the MDS in both the processing list and the presence list HANDLE Handle for synchronization with the response telegram Initialized Window event which the application uses to wait for the response telegram mobyErr_t Pointer to the structure in which the status byte is to be stored with possible error code and interface error See chapte 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter MOBY API C Library 4 J31069 D0137 U001 A5 7618 55 MOBY API C Library 03 05 Notice The END command may only be sent to the SLG after the command moby_write moby_read moby_init or moby_status and no command may be queued on the SLG The antenna must be on If not an error message occurs If the MDS has already left the field of the SLG and the mode is 01 an error message is generated If however another MDS has entered the field of the SLG and the mode is 01 an error message is also generated Notice The command can only be used with MOBY U type MOBY_Ua or MOBY_Ub see table 3 3 This is MOBY U without multitagging MOBY API C Library 56 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 3 5 Function m
52. the contents of the entire data carrier can be copied from one MDS to another This function permits data to be written i e copied directly via the user program from one MDS a to another MDS destination Parameter mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData1 ulnt Value from 20 to 232 1 Identification number of MDS 1 source which is to be copied addr1 int 0 to maximum length of user data minus 1 Start address of the data to be copied from MDS 1 Address plus data length must be less than the end address idData2 ulnt Value from 20 to 232 1 Identification number of MDS 2 destination to which the data are to be copied 0 to maximum length of user data minus 1 Start address of the data to be copied from MDS 2 Address plus data length must be less than the end address len ulnt Number of the bytes to be copied 1 to maximum length of the user data sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram err mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapte Ene Return value gt 0 No error command executed lt 0 Interface error See chapte MOBY API C Library 4 J31069 D0137 U001 A5 7618 83 MOBY API C Library 03 05 Notice The moby_s_cop
53. with any error codes and interface errors is to be stored see chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter MOBY API C Library 4 J31069 D0137 U001 A5 7618 89 MOBY API C Library 03 05 90 Notice The moby_s_writeOTP command may only be sent to the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If the MDS with the identification number specified by the specific call is not located in zone 1 the command is terminated with an error If there is a non specific call and no MDS is located in zone 1 the command waits until an MDS enters zone 1 or the RESET command arrives If there is a non specific call and more than one MDS is located in zone 1 the command is terminated with an error Notice The OTP memory can only be written once This write access must contain all 128 bits of information A second attempt to write access this memory is rejected with an error message MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 5 DI DO Functions The DI DO functions moby_readDE and moby_writeDA can be used to read scan digital inputs DI and write set digital outputs DO They can only be used with the SLG on the ASM 420 and SIM 41 3 5 1 Function moby_readDE mobyErr_t moby_readDE mobyHandle_t handle mobyDEDA_t deda HANDLE sync mobyErr_t err This f
54. with driver TCP IP ioj x Welcome to the MOBY API with driver f TCP IP Setup Wizard ew Sc P 5 The installer will guide you through the steps required to install MOBY API with driver TCP IP on your computer Click Next to continue WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel Figure 2 15 Activation of the installation of the C library link to Ethernet Next activates the installation The screen for selecting the directory for the MOBY API C library figure appears Cancel terminates the installation with previous confirmation MOBY API C Library 30 4 J31069 D0137 U001 A5 7618 03 05 Installation 3 Selecting the directory for the MOBY API C library i MOBY API with driver TCP IP Select Installation Folder The installer will install MOBY API with driver TCP IP in the following folder To install in this folder click Next To install to a different new or existing folder enter one below or click Browse Folder C Program Files MOBY APIS Browse You can install the software on the following drives 4001 576 wil Disk Cost Cancel Previous Figure 2 16 Selection of the directory for the installation link to Ethernet
55. 0 hex Byte 0 1 2 3 4 5 to 4 7 to4 7 n Parameter ABL 04 Status Sinfo n 1 FKT n 1 nth FKT n max ABL Binary value Telegram length in bytes without AB byte 4 7 n 0 lt n lt 33 4 to max of 236 Status Bit pattern 00 hex S info Binary value 02 hex SLG diagnosis mode n Binary value Number of functions called last 0 to 33 1st FKT Binary value 1 function Function data with length of 7 bytes nth FKT Binary value nth function Function data with length of 7 bytes Acknowledgment with error status not equal 00 hex Byte 0 1 2 Parameter 02 04 Status Status Bit pattern For status see appendix B 6 MOBY API C Library 4 J31069 D0137 U001 A5 7618 151 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 2 2 2 4 SLG STATUS Acknowledgment SLG Diagnosis II Acknowledgment without error status 00 hex Byte 0 1 2 3 4 4 1 Parameter ABL 04 Status S info n 1 FM n 1 4 n nth FM n max ABL Binary value Telegram length in bytes without AB byte 4 n 0 lt n lt 233 4 to max of 238 Status Bit pattern 00 hex S info Binary value 03 hex SLG diagnosis I mode n Binary value Number of error messages that occurred last 0 to 233 1 FM Binary value 1 error message number 1 byte nth FM Binary value nth error message number 1 byte Acknowledgment with error status not equal 0
56. 0 hex Byte 0 1 2 Parameter 02 04 Status Status Bit pattern For status see appendix B 6 MOBY API C Library 152 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 2 2 2 5 SLG STATUS Acknowledgment SLG Diagnosis III Acknowledgment without error status 00 hex Byte 0 1 2 3 4 5 to 4 4 Parameter ABL 04 Status Sinfo n 1 MDS no n 1 to4 4 n nth MDS no n max ABL Binary value Telegram length in bytes without AB byte 4 4 n O lt n lt 24 4 to max of 100 Status Bit pattern 00 hex S info Binary value 04 hex SLG diagnosis III mode n Binary value Number of MDSs identified last 0 to 24 1 MDS no Binary value 1 MDS number 4 bytes nth MDS no Binary value nth MDS number 4 bytes Acknowledgment with error status not equal 00 hex Byte 0 1 2 Parameter 02 04 Status Status Bit pattern For status see appendix B 6 B 2 2 2 6 L UEB Acknowledgment Byte 0 1 2 Parameter MOBY API C Library 4 J31069 D0137 U001 A5 7618 153 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 2 2 3 B 2 2 3 1 B 2 2 3 2 154 Messages Startup Message Byte 0 1 2 Parameter 02 00 OF The SLG U92 sends a startup telegram after the SLG U92 is powered up ANW MELD Message Byte Oo 1 2 3 4 Parameter 04 OF Stat
57. 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Acknowledgment Byte 0 1 2 3 4 5 6 7 8 9 10 11 CHN OA 50 Status HR ANW Counter 05 ID number HR ANW Bit 7 6 5 2 1 0 0 0 0 0 0 0 HR ANW MOBY API C Library 134 4 J31069 D0137 U001 A5 7618 03 05 Description of Communication to the ASM 424 724 824 with 3964R Protocol CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Status MOBY status HR Historical read There was just enough time to generate the data e g due to high speed data memory ANW 0 MDS not present 1 MDS present Counter Is incremented by 1 for each new telegram 00 to FF Hex ID number Identification number of MDS F1xx 5 bytes The next command is not a normal READ command as described in This command is used to control data flow The data were acquired automatically with the ASM and must be read in with this command This command can be used to fetch an existing read only telegram If no telegram exists the ASM sends one as soon as a new one arrives A 8 Mobile Data Memories Types of memories Mobile data memories with different memories are available to the user Table A 3 Types and sizes of memory Normal with ECC Net capacity in ECC mode 1 ECC mode cannot be used with MOBY E F MOBY API C Library 4 J31069 D0137 U001 A5 7618 135 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05
58. 18 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver Byte 0 1 2 3 Parameter 03 OD 00 mode Mode Binary value 00 hex Repeat until this command returns mode 1 01 hex Conclude repetition An already started command is processed until the end The MDS command to be executed or the command chain to be executed must contain correct parameters or have already been executed once without errors If the MDS command or the command chain is to be used on different types of MDSs 2 kbyte or 32 kbyte the area to be addressed must be adhered to since otherwise an OD hex error might occur Repeat mode is also retained even after an error occurs Notice When the REPEAT function is triggered after a RESET SLG STATUS SET ANT GET COPY or END command the function is rejected with an error status When automatic command repetition is activated and an SLG STATUS is called the SLG STATUS is executed asynchronously Automatic command repetition remains active When an additional MDS enters the antenna field while the command is being executed command execution is terminated with error 1D hex This means that with a command chain every telegram from this time on is acknowledged with an error status When only one MDS is still located in the field the command or the command chain is executed on this MDS When the MDS command or the command chain without the END command was executed on
59. 200 38400 57600 or 115200 baud e SLG U92 Slave with automatic baud rate recognition MOBY API C Library ie 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 2 MOBY Call Compatible Version 1 B 2 1 Telegrams to the SLG U92 MDS functions e INIT e WRITE e READ Initialize MDS Write data block Read data block System functions e RESET Reset SLG e SLG STATUS SLG status diagnosis e L UEB Cable monitoring The RESET command resets the SLG U92 to a defined state You determine how the SLG U92 system reacts by specifying the parameters of this command Telegram overview Telegrams Function Telegram Header User Data Max of 251 Bytes 0 1 2 3 to max of 253 bytes Status User data hex hex Date Address Address Standby Mode AB ABL Notice SLG STATUS L UEB Telegram length in bytes without the AB byte Variable telegram length in bytes without the AB byte depending on the length parameter gt 5 length The data are shown in the telegram overview and in the following individual telegram presentations in hexadecimal format hex MOBY API C Library 4 J31069 D0137 U001 A5 7618 141 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 2 1 1 B 2 1 1 1 142 MDS Functions The MDS functions INIT READ and WRITE read or write
60. 31069 D0137 U001 A5 7618 03 05 Introduction MOBY application 30 Figure 1 2 MOBY application 1 with MOBY_API_T LIB C library MOBY_API_T DLL dynamic link library Operating system Windows 98 NT 4 0 2000 or XP TCP IP protocol ASM 480 3964R protocol SLG U92 MOBY API structure with link to Ethernet The functions are available as DLL Dynamic Link Library in the MOBY_API_T DLL dynamic link library and the function calls in the MOBY_API_T LIB C library e Maximum of one application per SLG U92 e One link library for a maximum of 30 applications A header file with function declarations must be integrated in each MOBY application e Header file MOBY_API_T H The header file MOBY_API_T H must be integrated in the source code of the application with the preprocessor command include This declares all function calls and constants The header file was developed with and for Visual C If you want to use a different programming language or a C dialect of another company you may have to adjust the header file MOBY API C Library 4 J31069 D0137 U001 A5 7618 11 Introduction 03 05 Sample applications In addition to the C library two sample applications are included for an easy introduction to implementation of a user application e Executable application MOBY API EXE for control of up to four SLG U92 devices with ASM 480 which is also available in source code e Simple sample application TEST
61. 4R Driver 03 05 B 4 2 1 4 GET Acknowledgment Acknowledgment without error status 00 hex Depending on the function call and whether MDSs are located in the antenna field zone 1 the acknowledgment has the following structure GET function with mode 0 without MDS data and no MDS in the field Byte 0 1 2 3 Parameter 03 OC status Number of MDSs Status Bit pattern 00 hex Number of Binary value 0 No MDS in the field MDSs GET function with mode 0 without MDS data and at least 1 MDS in the antenna field zone 1 Byte 0 1 2 3 4 to 3 4 n Parameter ABL OC status Number of MDSs 1st MDS no nth MDS no ABL Binary value Telegram length in bytes without the AB byte 7to3 4 n 1 lt ns 12 n Number of MDSs in the antenna field zone 1 4 bytes for each MDS no Status Bit pattern 00 hex Number of Binary value Oto 12 Number of MDSs in the antenna field MDSs zone 1 n 1st MDS Binary value Value 2 to 2 1 MDS no of the 1st MDS no nth MDS Binary value Value 2 to 2 4 MDS no of the nth MDS no GET function with mode 1 with MDS data and no MDS in the field Byte 0 1 2 3 Parameter 03 OC status Number of MDSs Status Bit pattern 00 hex Number of Binary value 0 No MDS in the field MDSs MOBY API C Library 1 4 J31069 D0137 U001 A5 7618 Programming the SLG U92 Based on the Operating System or 3964R Drive
62. 7618 193 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 194 h Version a b c d or f plus SET ANT AUS with SLG STATUS in any i position RESET command plus followed by versions a b c or d with SLG STATUS in any position after the RESET Commands which are not permitted in the command chain or illegal chaining COPY GET and REPEAT are not permitted in the command chain COPY and GET only with multitagging RESET within or at the end of a command chain END at the beginning or within a command chain END without preceding MDS command SET ANT AUS at the beginning or before the last MDS command or before the END Example of chained MDS commands 3 READ commands chained 506 bytes in one data block AB Com Status Address Length mand 05 42 00 00 00 F8 AB Com Status Address Length mand 05 42 00 00 F8 F8 AB Com Status Address Length mand 05 02 00 01 FO 0A 1st command Read 248 bytes 2nd command Read 248 bytes 3rd command last command Read 10 bytes MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver e 3 READ commands chained 3 unrelated data blocks AB Com Status Address Length mand 05 42 00 00 00 14 AB Com Status Address Length mand o 42 oo ooro 1F AB Com Status Addre
63. 8 bits of information MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 15 Function moby_s_writeOTP mobyErr_tmoby_s writeOTP mobyHandle_t handle ulnt idData unsigned char data HANDLE sync mobyErr_t err You can use this function to execute a one time specific or non specific write access to the OTP memory One Time Programmable with a length of 16 bytes or 128 bits e A write call is specific when it includes the identification number of the MDS More than one MDS may be located in the antenna field You can determine the identification number of the MDS with the GET function e A write call is non specific when it does not include the identification number of the MDS Only one MDS may be located in the antenna field handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData ulnt Value from 20 to 232 1 Identification number of the MDS When only one MDS is located in the field and the write call is to be non specific data unsigned char Pointer to the buffer in which the data to be written to the OTP memory are stored The buffer must have a minimum length of 16 bytes sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram err mobyErr_t Pointer to the structure in which the status byte of the response telegram
64. After the RESET command has been executed the antenna of the SLG U92 is on B 3 1 2 2 SLG STATUS Function SLG Status Diagnosis See appendix MOBY API C Library 4 J31069 D0137 U001 A5 7618 159 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 3 1 2 3 B 3 1 2 4 160 SET ANT Function This function is used to turn the antenna of the read write device SLG U92 on or off Byte 0 1 2 3 Parameter 03 OA 00 Mode Mode Binary value 01 hex Turn on antenna 02 hex Turn off antenna The SET ANT command may only be sent to the SLG U92 when no command is queued on the SLG U92 yet At the time the antenna is turned on an MDS may already be present in the field of the SLG U92 If an MDS is in the field of the SLG U92 when the antenna is turned off this is reported as not present if the presence check is being used END Function This function is used to deactivate the standby time parameterized in RESET telegram of the MDS which was last processed and is still in the field of the SLG U92 This is done to reduce the current consumption of the MDS Byte 0 1 2 3 Parameter 03 08 00 Mode Mode Binary value 00 hex Processing with the MDS is concluded The MDS will leave the field of the SLG U92 zone 1 No further communication is to occur with this MDS The parameterized standby time becomes inactive The SLG U92 removes the MDS from the proce
65. DS memory 05 Unknown command wrong parameter function not permitted 06 Field interference on SLG gt The MDS left the field during communication gt Communication between SLG and MDS was terminated by external interference 077 08 09 OA 0B Memory of MDS cannot be read correctly OC Memory of MDS cannot be written OD Error in specified address address error gt The specified address does not exist on the MDS gt The command must be checked and corrected in telegram setup gt The MDS is not the right type 0E OF 10 NEXT command not permitted 196 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver MOBY API C Library 4 J31069 D0137 U001 A5 7618 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SLG doesn t have enough buffer to store the command Watchdog message from SLG U92 Wrong parameter in RESET function Only RESET command permitted Previous command still active Sending job on SLG repeated too often Data loss possible RESET command required Antenna is already off Antenna is already on Mode in SET ANT command is unknown Antenna is off and the MDS command cannot be executed Illegal number of MDSs in the field gt Greater than 1 For normal addressing MOBY call compatible versions 1 and 2 gt Greater than bunch specified in RESET command Wrong number of cha
66. DSs are located in the field of the SLG U92 when the antenna is turned off each individual MDS is reported as not present when presence mode is being used B 4 1 2 4 END Function You can use this function to reduce MDS power consumption by deactivating the standby time parameterized in the RESET telegram of an MDS located in the antenna field Byte 0 1 2 3 to6 7 Parameter 07 08 00 MDS no mode MDS no Binary value 0 When an MDS is located in the antenna field and a non specific call is to be performed Value 2 to 2 4 MDS no of the MDS for which the standby time is to be deactivated Mode Binary value 00 hex Processing with the MDS is finished The MDS will exit the field of the SLG U92 zone 1 No more communi cation is to take place with this MDS The parameterized standby time is deactivated The SLG U92 removes the MDS from the processing list but retains the MDS in the presence list until the MDS actually exits zone 1 MOBY API C Library 4 J31069 D0137 U001 A5 7618 181 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 1 2 5 182 01 hex Processing pause with the MDS The MDS doesn t exit the field of the SLG U92 zone 1 yet At least one other communication with the MDS is planned The parameterized standby time is deactivated The SLG U92 retains the MDS in the processing list and in the presence list Example READ command pause
67. Data With ECC Command 40 CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 AB Number of subsequent characters in the telegram Status MOBY status A ADRH Start address on MDS more significant portion of address ADRL Start address on MDS less significant portion of address Length Length of the data block data which were read Data Data which were read A 6 5 INIT Command Byte 0 1 2 3 4 5 6 7 CHN 06 18 00 INIT pattern 00 ADRH ADRL With ECC Command 1A MOBY API C Library 4 J31069 D0137 U001 A5 7618 131 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05 CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 INIT pattern During initialization the MDS is written with the value INIT pattern ADR H Amount of memory to be allocated more significant portion of the address ADRL Amount of memory to be allocated less significant portion of the address Acknowledgment Byte 0 1 2 3 CHN 02 18 Status With ECC Command 1A CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Status MOBY status A 6 6 STATUS Command Byte CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 Acknowledgment Byte 0 1 2 3 4 5 6 7 CHN 06 01 Status ANW Busy In In In res res res 7 6 5 4 3 2 1 0 0 0 0 0 0 0 ANW Busy
68. EN_ERROR 0xA012 define COM_READ_ERROR 0xA013 define COM_WRITE_ERROR 0xA014 define COM_SNR_ERROR 0xA015 define COM_CNF_ERROR 0xA016 define COM_WRITE_NAK 0xA017 define COM_WRITE_WRONG 0xA018 MOBY API C Library 4 J31069 D0137 U001 A5 7618 111 Header Files 03 05 define COM_DDFINI_ERROR OxA064 define COM_FRDPAR_ERROR OxA065 define COM_FOPPAR_ ERROR OxA066 define COM_FRDINI_ERROR OxA067 define COM_STRINI_ERROR OxA068 define COM_OPENSTR_ERROR OxA069 define COM_NO_CONFIG OxEOOL define COM_REGISTRY OxE002 define COM_NO_HANDLE 0OxE003 define COM_ERROR OxXFFFF LLLLLTLTLLTLT ATLL LLL T ATT T TTT ALT TTA TTT TTT ATTA TTT TAT TATA further constants define define define define define define define define define define define define define define define define 112 COM1 COM2 COM3 COM4 COM_NO_OPTION COM_OPEN STD BUF COM_GET_EVENT COM_READ EVENT COM_WRITE_ EVENT COM_S1 COM_S1 COM_S1 COoM_S1 CoM_S1 COM_S1 COoM_S1 TR R_OPEN R_RDWR R_ STATE R_EVENT R VERSION TR CLOSE COM1 COM2 COM3 COM4 OL 1 0x0000 0x0001 0x0002 NURWNERO MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Header Files 4 3 Header File MOBY_API_T H Headerfile for the MOBY API TCP Version 1 00 22 August 2003 Include this header file in any MOBY application Please make sure that the include path is set correctly
69. F hex Url V Binary value Bootstrap loader version 00 hex to FF hex 00 hex to FF hex FW ASCII format FW version FW V Binary value FW version 00 hex to FF hex 00 hex to FF hex Version high byte Version low byte Version high byte Version low byte Version high byte Version low byte MOBY API C Library 4 J31069 D0137 U001 A5 7618 149 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 TR TR V SS Baud dili mtag fcon ftim Sema 150 ASCII format Binary value Binary value Binary value Binary value Binary value Binary value Binary value Binary value Driver version T 3964R Driver version 00 hex to FF hex 00 hex to FF hex RS 232 RS 422 Version high byte Version low byte 01 hex RS 422 02 hex RS 232 Baud rate 01 hex 19 2 Kbaud 02 hex 38 4 Kbaud 03 hex 57 6 Kbaud 05 hex 115 2 Kbaud Distance limit 05 hex 0 5m OA hex 1 0m OF hex 1 5m 14 hex 2 0m 19 hex 2 5m 1E hex 3 0m 23 hex 3 5m Number of MDSs in the antenna field which can be processed multitag bunch 1 Proximity switch field ON control 00 hex Mode 1 No prox switches 01 hex Mode 2 1 or 2 prox switches The proximity switches are OR linked The field is on while the 1st and or 2nd proximity switch is on Otherwise off 02 hex Mode 3 1 or 2 prox switches The 1st proximity switch turns the field on an
70. G U92 models can be run on the ASM 480 with the RS 232 or RS 422 interface Depending on the SLG U92 model the serial interface type must be parameterized on the ASM 480 e Menu Parameter 3964R 1 Parameter RTS Control RS232 RTS off or RS422 RTS off The standard setting of the ASM 480 is the interface type RS 232 RS232 RTS OFF Notice The following parameters may not be changed on the ASM 480 e Menu Parameter TCP Parameter CRO Socket Type Server e Menu Parameter 3964R 1 Parameter Baudrate 38400 or 19200 e Menu Parameter 3964R 1 Parameter DataBits 8 e Menu Parameter 3964R 1 Parameter Stopbits 1 e Menu Parameter 3964R 1 Parameter Parity Odd Other parameters for the 3964R menu Parameter 3964R 1 include e Priority 3964R high e Idle time msec 0 e Receive mode Byte telegram e Send mode Word telegram MSB LSB e Error SCC Set clear e Send repetition 5 e Receipt delay 150 e Character delay 50 Notice The parameter CRO Port Number is parameterized with the default value 8000 and must be specified for the moby_open function under Parameter sPort see chapter e Menu Parameter TCP Parameter CRO Port Number 8000 MOBY API C Library 42 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 MOBY API C Library A variety of functions which can handle the entire communication are available in the C libraries for use with the SLG or SLA on the ASM and SIM e MOBY_API LIB
71. HANDLE sync mobyErr_t err If the last processed MDS is still in the field you can already activate processing of the next MDS after this function handle mobyHandle_t Handle of the serial interface and the channel number sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 8 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 3 4 Function moby_end mobyErr_tmoby_end mobyHandle_t handle unsigned char mode HANDLE sync mobyErr_t err This function is used to deactivate the standby time parameterized in RESET telegram of the MDS which was last processed and is still in the field of the SLG This is done to reduce the current consumption of the MDS handle mobyHandle_t Handle of the serial interface and the channel number mode unsigned char 00 hex Processing of the MDS is finished and the parameterized standby time is to be deactivated No more communication with this MDS is to take place The MDS will exit the field of the SLG The SLG removes the MDS from the processing list but retains the MDS in the presence list until
72. I with driver TCP IP Repair MOBY API with driver TCP IP C Remove MOBY API with driver TCP IP WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel Previous Figure 2 20 Overwriting an existing C library link to Ethernet If the existing MOBY API C library is to be overwritten select Repair MOBY API with driver TCP IP and then start the procedure with Finish see figure Notice Remember to accept the new header file MOBY_API_T H and the MOBY_API_T LIB C library in the development project MOBY API C Library 4 J31069 D0137 U001 A5 7618 35 Installation 03 05 8 Overwriting an existing MOBY API C library i MOBY API with driver TCP IP Installing MOBY API with driver TCP IP MOBY API with driver TCP IP is being installed Copying new files GRRGERERHRR EES Previous Figure 2 21 Screen during the overwrite installation procedure link to Ethernet The existing MOBY API C library is overwritten MOBY API C Library 36 4 J31069 D0137 U001 A5 7618 03 05 Installation 9 Overwriting an existing MOBY API C library is complete link to Ethernet ji MOBY API with driver TCP IP Installation Complete Figure 2 22 Overwrite procedure i
73. ID mobyHandle_t handle mobyMiget_t getInfo int address ulnt length HANDLE sync mobyErr_t err You can use this function to query which MDSs are located in the field At the same time you can read data from these MDSs handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface getinfo mobyMtget_t Pointer to the structure in which the number of polled MDSs the ID numbers of the MDSs and if necessary the read MDS data are to be stored address int Start address of the data on the MDS to be read 20 0 to maximum length of the user data minus 1 The address plus data length must be less than the end address on the MDS FFFO hex Start address of the OTP memory length ulnt Number of bytes to be read 20 0 to maximum length x x 242 4 bunch size bunch size 16 Length of the OTP memory sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram err mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapte 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter 3 7 1 Notice The moby_s_getID command may only be sent to the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is
74. MDS may be located in the antenna field e A read call is specific when the call includes the identification number of the MDS More than one MDS may be located in the antenna field You can determine the identification number of the MDS with the GET function Byte 0 1 2 3to6 7 8 9 Parameter 09 OB 00 MDSno mode cweek year MDS no Binary value 0 When an MDS is located in the antenna field and a non specific status query is to be performed Value 2 to 2 1 MDS no of the MDS which is to be queried Mode Binary value 00 hex Request status and diagnostic data of an MDS Current calendar week Cweek Binary value 1 to 53 Year Binary value 1 to 99 Current year beginning with 1 for 2001 The MDS STATUS command may only be issued to the SLG U92 when no command is queued on the SLG U92 The antenna must be on Otherwise an error message is generated When the call is non specific and there is no MDS in zone 1 an error message is generated When the call is non specific and there is more than one MDS in zone 1 the command is terminated with an error When the call is specific and the MDS with the specified MDS no is not located in zone 1 the command is terminated with an error The function sequence depends on the fields cweek and year a If the value in both fields is within the value range the remaining battery life is output in the response b If one of the value
75. MELD acknowledgment Bit 4 0 In reserve Bit3to0 6hex Operating mode MOBY U multitag processing bunch dili Binary value Range limitation zone 1 The read write range of the SLG U92 0 5 to 3 m can be limited in increments of 0 5 m 3 5 m must be parameterized for the maximum distance of 3 5 m Together with the range limitation the sending capacity can be reduced For reasons see the MOBY U manual for configuration installation and service Normal sending capacity Reduced sending capacity 05 hex 0 5m 85 hex 0 5m OA hex 1 0m 8A hex 1 0m OF hex 1 5m 8F hex 1 5m 14 hex 2 0m 94 hex 2 0m MOBY API C Library 4 J31069 D0137 U001 A5 7618 179 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 1 2 2 180 19 hex 1E hex 23 hex mtag Binary value 1 to 12 fcon Binary value 00 hex 01 hex 02 hex 03 hex ftim Binary value 0 1 to 255 Multitag bunch 2 5m 3 0m 3 5m 99 hex 9E hex A3 hex 2 5m 3 0m 3 5m Number of MDSs multitag bunch that can be processed in the antenna field zone 1 Proximity switch mode Mode 1 Without proximity switches or SLG synchronization Mode 2 One or two proximity switches The proximity switches are logically OR linked While the 1st and or 2nd proximity switch is are on the field is on Otherwise it is off Mode 3 One or two proximity switches The 1st proximity switch turns the field on The 2nd proximit
76. More than one MDS may be located in the antenna field You can determine the identification number of the MDS with the GET function Byte 0 1 2 3 to 6 7 8 9 10 tomax of 253 Parameter ABL 01 00 MDS no address length data ABL Binary value 1 to 253 Telegram length in bytes without the AB byte MDS no Binary value 0 When an MDS is located in the antenna field and a non specific write call is to be performed Value 2 to 2 4 MDS no of the MDS which is to be written Address Binary value 0 to maximum length of user data minus 1 Start address on the MDS of the data to be written The address plus data length must be less than the end address 16 FFFO hex Start address of the OTP memory Length Binary value 1 to 244 Length of the user data to be written 16 Length of the OTP memory Data Binary information User data to be written to the MDS The WRITE command may only be used on the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If the call is non specific and there is no MDS in zone 1 the command waits until an MDS moves into zone 1 or the RESET command arrives If the call is non specific and there is more than one MDS in zone 1 the command is terminated with an error If the call is specific and the MDS with the specified MDS no is not located in zone 1 the command is terminated with an error No
77. S is written with the specified byte from address 0 to address length 1 The rest of the memory is not changed MOBY API C Library 4 J31069 D0137 U001 A5 7618 71 MOBY API C Library 03 05 3 4 5 Function moby_statusMDS mobyErr_t moby_statusMDS mobyHandle_t handle mobyStatusMDS t statusMDS unsigned char mode unsigned char cweek unsigned char year HANDLE sync mobyErr_t err This function is used to request status and diagnostic data of an MDS handle mobyHandle_t Handle of the serial interface and the channel number statusMDS mobyStatusMDS_t Pointer to the structure in which the status and diagnostic information of the response telegram are to be stored mode unsigned char 00 hex Request status and diagnostic data of an MDS cweek unsigned char 01 to 35 hex Current calendar week 1 to 53 for determination of remaining battery life No determination of remaining battery life year unsigned char 01 to 63 hex The last two positions of the current year starting with 01 for determination of remaining battery life No determination of remaining battery life HANDLE Handle to synchronization with the response telegram Initialized Windows event which the application uses to wait for the response telegram mobyErr_t Pointer to a structure in which the status byte and any error code and_interface errors are to be stored See chapte Return value gt 0 No error command executed lt 0 In
78. SIEMENS MOBY MOBY API C Library Programming Instructions Published in March 2005 Introduction Installation MOBY API C Library Header Files Sample Application Description of Communication to ASM 424 724 824 with 3964R Protocol Programming the SLG U92 Based on Operating System or 3964R Driver 3964R Procedure Terms Abbreviations List of Literature elile le lelle e is Safety Guidelines gt amp amp This manual contains notices you have to observe in order to ensure your personal safety as well as to prevent damage to property The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring to property damage only have no safety alert symbol These notices shown below are graded according to the degree of danger Danger indicates that death or severe personal injury will result if proper precautions are not taken Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution with a safety alert symbol indicates that minor personal injury can result if proper precautions are not taken Caution without a safety alert symbol indicates that property damage can result if proper precautions are not taken Notice indicates that an unintended result or situation can occur if the corresponding information is not taken into account If more than one degree of danger is pres
79. SM SLG or SIM because a monitoring time is exceeded see chapter 2 23 error 0x000C can occur on the MOBY API C interface or error 0xA017 can occur directly on the 3964R driver An unexpected telegram may also occur which is not reported unless the callback routine is used See chapters 3 1 3 and 3 3 12 This unexpected telegram must be rejected e After error 0xX000C has occurred the moby_ start function must be called and the failed function must then be repeated The moby_stop function is not necessary If you call this function anyway error OxOOOF occurs e Following error OxA017 the command during which the error occurred can be repeated directly without moby_stop and moby_ start If an error occurs during moby_start close the COM interface with moby_close and then open it again MOBY API C Library 4 J31069 D0137 U001 A5 7618 97 MOBY API C Library 03 05 3 7 2 MOBY Status After a MOBY function is executed response telegram has arrived the MOBY status byte of the response telegram is stored under the mobyErr_t union addressed with the status pointer The status byte can be addressed as e Structure mobyStatus_t or e Long integer variable error See chapter 4 1 for header file MOBY_API H or chapter 4 3 for header file MOBY_API_T H The error and status information can be read from the individual structure parameters by bit or as a unit see also error numbers from the ASM or SIM with SLG or SLA in chapter 3 7 1
80. TATUS Acknowledgment SLG Diagnosis II SLG STATUS Acknowledgment SLG Diagnosis II MOBY API C Library 4 J31069 D0137 U001 A5 7618 3 Table of Contents 03 05 SLG STATUS Acknowledgment SLG Diagnosis SLG STATUS Acknowledgment SLG Diagnosis II MOBY API C Library 4 4 J31069 D0137 U001 A5 7618 03 05 Table of Contents SLG STATUS Acknowledgment SLG Diagnosis SLG STATUS Acknowledgment SLG Diagnosis II MOBY API C Library 4 J31069 D0137 U001 A5 7618 5 Introduction 03 05 1 Introduction 1 1 Product Overview The MOBY family of products includes a number of identification systems which are used throughout the world to control and optimize material flow in production manufacturing distribution and logistics The identification systems are made up of three components e Mobile data memories MDS e Read write devices SLG read write antennas SLA or serial interface modules SIM e Interface modules ASM These components are available in various models A uniform MOBY API C library is available for user specific MOBY applications for communication with the MOBY systems which are linked serially to PC with Windows 98 NT 4 0 2000 XP or to Ethernet with PC with Windows 98 NT 4 0 2000 XP It offers a simple and quick system link 1 2 Serial Link to PC The serial link of the MOBY systems to the PC with Windows 98 NT 4 0 2000 XP is provided by ASM SIM or SLG as shown in table 1 1 The MOBY compo
81. Y API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 8 Function moby_s read mobyErr_tmoby_s read mobyHandle_t handle ulnt idData ulnt mdsAddress unsigned char data ulnt length HANDLE sync mobyErr_t err You can use this function to specifically or non specifically read data from an MDS which is located in the antenna field of the SLG U92 e With a specific read call the call contains the identification number of the MDS More than one MDS may be located in the antenna field The identification number of the MDS can be determined with the GET function e With a non specific read call the call does not contain the identification os of the MDS Only one MDS may be located in the antenna field Parameter mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData ulnt Value of 20 to 232 1 ID number of MDS 0 Only one MDS is located in the field and a non specific read call is to be used mdsAddress_ ulnt Start address of the data on the MDS to be read 0 0 to maximum length of user data minus 1 The address plus data length must be less than the end address on the MDS data unsigned char Pointer to the buffer in which the read data are to be stored length ulnt Number of bytes to be read 1 to maximum of 244 bytes sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the applicat
82. a type for accessing DE DA when available typedef struct mobyDEDA d BOOL mobyDEDA t typedef void CAL typedef void CAL bitDAO bitDA1 bitDA2 bitDA3 bitDEO bitDE1 bitDE2 bitDE3 BACK moby_UnexpCallback_ t BACK moby_AnwCallback_t unsigned char chi unsigned char ch2 unsigned char ch3 int laenge unsigned char anwstatus LLTLLTLLLLTTTALLTTLTTT ALLL TATTLE TT ATA TTT TAT TTT Interface of the MOBY API if defined __ cplusplus extern C endif DLLROUTINE mobyErr_t DLLDECL moby open DLLROUT DLLROUT NE NE DLLDECL DLLDECL mobyErr t ne moby_close mobyErr t moby start NE s1ROUTI mobyErr t DLLDECL mobyErr_t DLLDECL moby stop moby next DLLROUTINE mobyErr_t DLLDECL moby status ROUTINE mobyErr_t DLLDECL moby _statusU LPCSTR com_name int channel mobyHandle_t handle mobyH mobyH andle_t handle andle_t handle mobyType_t type BOOL eccOn mobyParameters_t param HANDLE sync mobyErr_t err mobyH mobyH andle_t handle andle_t handle HANDLE sync mobyErr t err mobyH andle_t handle mobyStatus_t stat HANDLE sync mobyErr_t err mobyH andle_t handle mobyStatusU_t stat HANDLE sync mobyErr_t err 106 NE mobyErr t DEC moby diagnose mobyHandle_ t handle unsigned char mode mobyDiagnose_t diagnose HANDLE
83. alue after erroneous function execution The returned handle is used for all other functions as the input parameter for identification of the Ethernet interface sPort unsigned short Port number under which the ASM 480 is addressed see chapter 2 3 1 Return value gt 0 No error command executed lt 0 Windows is unable to open the Ethernet interface see chapter ora Function moby_close mobyErr_tmoby_close mobyHandle_t handle This function closes the specified MOBY device with the help of the driver The MOBY device can then no longer be accessed This routine is required for communication with the MOBY device with moby_start see chapter 3 3 1 However it is not used until after the user calls moby stop see chapter 3 3 2 Otherwise an error is returned handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface Return value gt 0 No error command executed lt 0 Windows is unable to close the serial interface or the Ethernet interface see chapter 3 7 1 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 3 3 3 1 System Functions The system functions are used to control communication with an SLG or SLA on an ASM or a SIM They provide the function framework for the MDS functions see chapter 3 4 but do not affect the MDS directly Table 3 2 Assignment of the system functions to the interfaces Function e S
84. amp err2 if errl error MOBY_OK WaitForSingleObject sync INFINITE errl error volatile int err2 error CloseHandle sync return errl error MOBY API C Library 118 4 J31069 D0137 U001 A5 7618 03 05 Sample Application start and synchronize reset start int MOBY reset int comdev void CALLBACK status int HANDLE sync mobyErr t errl err2 mobyParameters t param MOBY CHANNEL PARAM RESET This initialization should be done to avoid side effects sync CreateEvent NULL FALSE FALSE NULL As param has been initialized only necessary fields have to be set now ifdef USE MOBY E param channelasm param fields mode MOBY CHANNEL E RESETPARAM MODE else param channelasm param fields anw MOBY CHANNEL RESET PARAM ANW DETECT ifdef USE MDS Flxx param channelasm param fields mode MOBY CHANNEL F RESETPARAM MODE MDS F1xx else param channelasm param fields mode MOBY CHANNEL F RESETPARAM MODE MDS F4xx endif param channelasm opt fields clear_led 1 endif change the parameters in the following call to adapt to other MOBY types ifdef USE MOBY E errl moby_ start comdev MOBY _E FALSE amp param sync amp err2 else errl moby_ start comdev MOBY F FALSE amp param sync amp err2 endif if errl error MOBY_OK WaitForSingleObject sync INFINITE errl error volatile int err2 error CloseHandle sync return errl error
85. an MDS located in the antenna field and then another MDS enters the field the MDS command or command chain to be executed is terminated with error 1D hex This means that with a command chain each telegram is acknowledged with an error status Caution No check is made to determine whether OTP memory was addressed in a write command With automatic repetition each MDS would receive the same OTP memory content B 4 1 2 6 L UEB Function See appendix MOBY API C Library 4 J31069 D0137 U001 A5 7618 183 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 2 184 Acknowledgments Messages from the SLG U92 Telegram overview Telegram Header User Data Max of 251 Bytes 0 Acknowledg ment message hex 1 2 Status hex 3 to max of 253 MDS no User data hex MDS no ABL 02 00 MDS no address length data ABL 0c 00 Number of MDSs 1st MDS no nth MDS no address data MDS 1 length data MDS n COPY MDS no 1 MDS no 2 MDS STATUS 12 RESET 0B 00 MDS no MDS type x Subframe access Search mode access x MCOD SLG STATUS SLG status Status information SLG STATUS diagnosis Diagnostic information SLG STATUS diagnosis II Diagnostic information SLG STATUS diagnosis III SET ANT END
86. artup the ASM attempts to send a startup telegram during which the 3 different Baud rates are tested up to two times When the telegram is sent successfully that Baud rate is considered recognized If not the ASM waits for a telegram STX and then acknowledges with DLE during the second STX when the Baud rate is found The Baud rate cannot be changed during operation Notice When a telegram cannot be sent due to a transmission error all four channels are reset i e the commands are deleted Protocol Settings The ASM is permanently parameterized to master when an initialization conflict occurs The 3964R driver of the ASM uses the following settings e Attempts to establish the connection 3 e Attempts to make block transmission 6 e Acknowledgment delay time 2 sec e Character delay time 220 msec e Block wait time 10 sec e Wait time for subsequent telegrams to be sent 10 to 20 msec The type of interface can be set with the parameterization switch 8 Up RS 422 Down RS 232 The other parameters are transferred with the RESET command MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Description of Communication to the ASM 424 724 824 with 3964R Protocol A 3 LEDs on the 3964R Interface Side of the ASM Table A 1 LEDs on the ASM LED ON green Power on LED i ASM is powered ACT green This LED flashes once briefly to indicate that a command has been executed successfully not for status comma
87. ate You determine system behavior of the SLG U92 by specifying the necessary parameters Standard settings e Read write distance up to 1 5m e Bunch multitag 1 e Without proximity switches The SLG U92 does not evaluate the digital inputs on the service interface Byte 0 1 2 3 4 5 Parameter 05 00 00 Standby Param 00 U Bit 7 6 15141 3210 Standby Binary value Time in which the MDS is to remain in standby after an executed MDS command This means that during this time the MDS remains awake so that the next command which must arrive within this standby time can be processed without delay The value doesn t specify the time directly Instead it gives a 7 msec factor For example a value of 10 means 10 x 7 msec 70 msec 0 No standby time After each communication with the MDS the MDS goes to sleep again 1 to 200 7 msec to 1400 msec Param Bit pattern Parameter Bit7to6 0 Bit 5 0 Operation without presence check 1 Operation with presence check see ANW MELD acknowledgment telegram Bit 4 0 In reserve Bit3toO 5Shex Operation mode MOBY U gt MOBY I commands without expansions The RESET command may always be sent to the SLG U92 and is executed immediately If another command is waiting it is terminated After execution of the RESET command the antenna of the SLG U92 is turned on MOBY API C Library 4 J31069 D0137 U001 A5 7618 145
88. atus byte Table 3 3 MOBY error code Error Assignment to ASM SIM SLG No error Response x x x x x x telegram correct 01 ANW error MDS left field x x x x x x while command active ANW error MDS passed SLG without command A queued MDS command was terminated by the turn off antenna command 03 Error in connection to the SLG SIM SLA 04 Error in memory of MDS x x x x x x not initialized 05 Command from SLG ASM x x x x x x cannot be interpreted Field interference on e 07 Too many Too many sending errors errors MDS reports CRC errors very frequently om INIT CRC error INIT MDS cannot be initialized MOBY API C Library 4 J31069 D0137 U001 A5 7618 99 MOBY API C Library 03 05 Table 3 oe MOBY error code ES Assignment to ASM SIM SLG eo ee ASM 824 ASM 724 ASM 424 Asm 420 sim41 SLG u92 INIT Timeout during initialization MDS memory cannot be read correctly INIT Write error during initialization Repeated storing on ee ae Ca joD Addresserror error ECC mode Data on MDS are wrong RESET message after De of E A 10 NEXT command is NEXT command is illegal 11 Short circuit or overload on x T a outputs 142 Internal firmware error firmware error 13 Watchdog There is not enough buffer space on the SLG to store a ae command 14 Firmware error error Watchdog message from SLG U Parameter assignment error Unsuitable connection T
89. be read with one telegram With ASM 824 up to 192 bytes can be read with one telegram MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 2 Function moby_getID mobyErr_tmoby_getID mobyHandle_t handle unsigned char idData ulnt idLength HANDLE sync mobyErr_t err The moby_getID function is used to read the identification number serial number of the MDS This is only possible with the MDSs of MOBY E MOBY F and MOBY U handle mobyHandle_t Handle of the serial interface and the channel number idData unsigned char Pointer to the buffer in which the read ID number is to be stored idLength ulnt Length of the ID number of the MDS in bytes gt 0 Length of the ID number MOBY E ID length 4 bytes MOBY F MDS F1xx ID length 5 bytes MOBY F MDS F4xx ID length 4 bytes MOBY U ID length 4 bytes HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes rface errors is to be stored see 372 Return value 20 No error command executed lt 0 Interface error See chapter 374 Notice The start address of the ID on the MDS is handled internally e MOBY E Start address 1FFO Hex e MOBY F MDS F1xx Start address 0000 Hex e MOBY F MDS F4xx Start address 0000 Hex T
90. by the SLG ASM or SIM the appropriate event is set to signal the calling thread that the function has now been completely concluded Any error information in the response telegram is written to a memory word which was specified when the routine was called Matching Response Telegrams Arriving telegrams must be matched with previous command telegrams This is done by command numbers in the sequence of FIFO first in first out Unexpected Telegrams Unexpected telegrams may sometimes be received by the SLG ASM or SIM A few examples of unexpected telegrams e Startup message 02 00 OF hex e Telegrams after MOBY DLL was reset which come back from SLG ASM or SIM but whose entry was deleted from the match buffer The calling process handles these telegrams A callback routine can be specified which is to be called when an unexpected i e keete telegram arrives Unexpected telegrams can also be ignored see chapter 3 3 12 MOBY API C Library 4 J31069 D0137 U001 A5 7618 45 MOBY API C Library 03 05 46 Connection Monitoring With an Ethernet link the connection between the MOBY DLL and the individual SLG is monitored at the telegram level When more than 3 seconds pass after the last telegram from the SLG the MOBY DLL automatically sends a monitoring telegram to the SLG and expects the SLG s reply within 10 seconds When a telegram is still not received from the SLG within these 10 seconds the connection to the SLG
91. d calendar year 01 are output MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver Remain Binary value 16 bits Remaining battery life as percentage batt ST Binary value Sleep time Value set on MDS 0 20 msec 6 7 msec 1 40 msec 13 3 msec 2 80 msec 26 7 msec 3 160 msec 53 3 msec 4 320 msec 106 7 msec default 5 640 msec 213 3 msec 6 1280 msec 426 7 msec 7 2560 msec 853 3 msec Statistically tolerance range of each MDS is equally distributed Acknowledgment with error status not equal 00 hex Byte 0 1 2 Parameter 02 OB Status Status Bit pattern For status see appendix B 6 B 3 2 2 Acknowledgments to System Functions B 3 2 2 1 RESET Acknowledgment See appendix B 2 2 2 1 B 3 2 2 2 SLG STATUS Acknowledgment SLG Status Acknowledgment without error status 00 hex Byte 0 1 4 5 6 7 8 9 10 11 2 3 Parameter 1B 04 Status S info Hw HWw v unv FW FW v 12 1314 15 16 17 18 19 20 21 22 TR TR V ISS Baud 00 00 00 dili mtag fcon 23 24 25 26 27 ftim Sema ANT Standby ANW Status Bit pattern 00 hex MOBY API C Library 4 J31069 D0137 U001 A5 7618 165 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 166 S info HW HW V Url V FW FW V TR TR V SS Baud dili mtag
92. d the 2nd turns the field off When two proximity switches exist and one proximity switch is parameterized the field is automatically turned off when the 2 proximity switch does not switch within this proximity switch time If the 2 proximity switch does not exist one proximity switch time must be parameterized After this time the field is automatically turned off Proximity switch time field ON time 0 No proximity time see proximity switch mode 1 to 255 1 to 255 seconds Semaphore control synchronization with SLG 01 hex Yes 02 hex No MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 2 2 2 3 ANT Binary value Status of antenna 01 hex Antenna on 02 hex Antenna off Standby Binary value Time after an executed MDS command for standby of MDS 0 No standby After each time communication with the MDS occurs the MDS goes to sleep The MDS cannot be read or written until after the sleep time 1 to 200 7 msec to 1400 msec ANW Binary value Presence see RESET 00 hex Operation without presence check 01 hex Operation with presence check see ANW MELD acknowledgment Acknowledgment with error status not equal 00 hex Byte 0 1 2 Parameter 02 04 Status Status Bit pattern For status see appendix B 6 SLG STATUS Acknowledgment SLG Diagnosis l Acknowledgment without error status 0
93. de_ Cweek Year Mode Binary value 00 hex Request status and diagnostic data of an MDS Cweek Binary value 1 to 53 Current calendar week Year Binary value 1 to 99 Current year starting with 1 for 2001 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 3 1 2 B 3 1 2 1 The MDS STATUS command may only be sent to the SLG U92 when no command is queued on the SLG U92 The antenna must be on Otherwise an error message is generated If there is no MDS in zone 1 an error message is sent When more than one MDS is located in zone 1 the function is terminated with an error The function sequence depends on the fields cweek and year a If the values in both fields are within the value range the remaining battery life is output in the response oO a If one of the values is not within the specified value range remaining battery life cannot be calculated and the function is terminated with an error O S If both values contain FF hex days remaining battery life is not calculated and battery life is specified in the acknowledgment as FFFF hex System Functions RESET Function The RESET command is used to reset the SLG U92 to a defined state You determine the system reaction of the SLG U92 by specifying the appropriate parameters Standard setting e Bunch multitag 1 Byte 0 1 2 3 4 5 6
94. do not wait directly for the response telegram The functions are continued after the telegram was sent successfully without errors or terminated with errors The application must then wait for the response telegram using an initialized Windows event which must be included when the function is called As soon as the response telegram is received the event is set This signals the application that the function is finished This procedure ensures that all functions which affect SLG SIM or ASM do not block each other Notice e With ASM 424 ASM 420 with SLG 4x and SIM 41 MDS functions with ECC offset are possible e The Windows event must be generated with CreateEvent MOBY API C Library 44 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 1 1 General Information on Use of MOBY API C Library Synchronization Every routine which generates a response telegram from the SLG ASM or SIM MOBY device to the host after the command is concluded must be synchronized To do this each of these routines has a type HANDLE parameter This parameter must point to an initialized Windows event which was created with CreateEvent When one of these routines is called the calling thread is blocked until the appropriate action is started i e until a telegram is completely sent to the SLG ASM or SIM The calling routine then returns without waiting for a response telegram As soon as the response telegram is received
95. e 17 Protocol error error 18 Only RESET command x permitted Previous command is xX x x active Buffer overflow telegram buffer full 1A 3964R error connection interrupted 1B Sending job on SLG repeated too often Data loss possible RESET command required Turn antenna on off MOBY API C Library 100 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library Table 3 3 MOBY error code ES Assignment to ASM SIM SLG ES ASM 824 ASM 724 ASM 424 asm 420 sim41 SLG u92 Number of MDSs gt bunch of MDSs gt bunch Wrong number of characters in the telegram SLG ASM command deleted with RESET Long integer variable error 1D Not enough RAM on the nna When the error and status information is read as a long integer value the individual pieces of information must be evaluated by masking MOBY API C Library 4 J31069 D0137 U001 A5 7618 101 Header Files 03 05 4 Header Files The header file e MOBY_API H for serial link to PC or e MOBY_API_T H for link to Ethernet must be integrated with the include preprocessor command This declares all function calls and constants 4 1 Header File MOBY_API H Headerfile for the MOBY API Version 4 40 14 June 2002 Include this header file in any MOBY application Please make sure that the include path is set correctly ifndef MOBYAPIDEFINED define MOBYAPIDEFINED LILELITLLTTLTTL TTL TTL TTA TTA TTA TTA TTA TTA TTA
96. e 3964R protocol is a DLL Dynamic Link Library The telegrams are generated or received by library functions The library functions are based on the 3964R driver and provide the interface between MOBY applications and MOBY systems MOBY API C Library 4 J31069 D0137 U001 A5 7618 Introduction 03 05 MOBY application 4 MOBY application 1 with C library MOBY_API LIB Dynamic link library MOBY_API DLL 3964R driver Dynamic link library 3964R DLL Operating system Windows 98 NT 4 0 2000 or XP ASM 420 ASM 424 ASM 724 ASM 824 One One to four One to four One to four SLG 4x SLG 4x or SLA 71 SLA 81 SLG U92 or SLG 7x SLG 7x Figure 1 1 Structure of MOBY API for serial link to PC The functions are available as DLL in the dynamic link library MOBY_API DLL and the function calls in the C library MOBY_API LIB e Maximum of one application per ASM SIM or SLG U92 e One link library for up to four applications The driver functions must be configured as a CPL file under the system controller of Windows e Configuration program CPL3964R CPL A header file with function declarations must be linked to each of the MOBY applications e Header file MOBY_API H MOBY API C Library 8 4 J31069 D0137 U001 A5 7618 03 05 Introduction The MOBY_API H header file must be linked to the source code of the application with preprocessor command include This declares all function calls and constants
97. e ASM 480 is used as the protocol converter between the TCP IP protocol and the 3964R protocol 1 3 1 MOBY Systems Which Can Be Connected to Ethernet Table 1 2 Components which can be used with MOBY API with coupling to Ethernet MOBY Product Family Interface Related Documentation MOBY U ASM 480 with SLG U92 without filehandler 1 3 2 MOBY API C Library for Link to Ethernet The MOBY API C library product for user specific MOBY applications can be executed under Windows 98 NT 4 0 2000 XP It is used for the implementation and execution of MOBY applications with the following components e C library MOBY_API_T LIB e MOBY header file MOBY_API_T H e Dynamic link library MOBY_API_T DLL e Sample applications Executable MOBY API EXE stored under EXAMPLE ZIP subdirectory MOBY_API_T Source code of the executable sample application MOBY API EXE stored under EXAMPLE ZIP subdirectory MOBY_API_T Source code for a simple sample application stored under EXAMPLE ZIP subdirectory TEST Control of the read write devices SLGs is handled on Ethernet via transmission of structured telegrams which are transferred to the serial interface of the SLG with the 3964R protocol The telegrams are generated or received via library functions The library functions are based on the TCP IP driver dynamic link library and provide the interface between the MOBY applications and the MOBY systems MOBY API C Library 10 4 J
98. e for ASM 824 with MDS F1xx and ASM 724 MOBY API C Library ae 4 J31069 D0137 U001 A5 7618 03 05 Description of Communication to the ASM 424 724 824 with 3964R Protocol MOBY operating mode The following MOBY operating modes can be set on your ASM MOBY I ASM 424 1 MOBY I MOBY E SLG 7x 2 Reserved 4 MOBY I with MDS 507 8 Reserved for MOBY dialog 9 Reserved for MOBY V A MOBY F with MDS F1xx B MOBY F with MDS F4xx C MOBY F with MDS F2xx MOBY E ASM 724 0 All parameters in the RESET telegram are ignored default setting 1 MOBY E SLA 71 MOBY F ASM 824 0 All parameters in the RESET telegram are ignored default setting A MOBY F SLA 81 and MDS F 1xx read only B MOBY F SLA 81 and MDS F4xx read write Option 1 TST_ON 1 ASM responds with error if field interference on SLG only for ASM 424 Timeout 1 ASM responds with error if no MDS is in its field only for ASM 424 CLR_LED 1 ERROR_LED channel specific is cleared Notice The parameters in the RESET telegram are only used for the first telegram after power ON i e parameter changes do not take effect until the power is turned off and on again All channels must be parameterized with the same MDS Mixing is not possible MOBY API C Library 4 J31069 D0137 U001 A5 7618 129 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05 Acknowledgment
99. ed char data uInt length HANDLE sync mobyErr_t err mobyHandle_t handle uInt idData uInt mdsAddress unsigned char data uInt length HANDLE sync mobyErr_t err mobyHandle_ t handle unsigned char idData uInt idLength HANDLE sync mobyErr_t err mobyHandle_t handle mobyMtget_t getInfo int address uInt length HANDLE sync mobyErr t err mobyHandle _t handle uInt mdsAddress unsigned char data uInt length HANDLE sync mobyErr_t err mobyHandle_ t handle uInt idData uInt mdsAddress unsigned char data uInt length HANDLE sync mobyErr_t err mobyHandle_t handle unsigned char setVal uInt mdsLength HANDLE sync mobyErr _t err mobyHandle_ t handle uInt idData unsigned char setVal uInt mdsLength HANDLE sync mobyErr_t err mobyHandle _t handle mobyDEDA t deda HANDLE sync mobyErr_t err mobyHandle _t handle mobyDEDA t deda HANDLE sync mobyErr_t err mobyHandle _t handle moby UnexpCallback_t cbroutine mobyHandle _t handle moby AnwCallback_t cbroutine int major int minor mobyHandle _t handle unsigned char mode HANDLE sync mobyErr_t err mobyHandle_t handle uInt idData unsigned char mode HANDLE sync mobyErr _t err mobyHandle_t handle unsigned char mode HANDLE sync mobyErr_t err mobyHandle_t handle unsigned char mode HANDLE sync mobyErr_t err mobyHandle _t handle mobyStatusMDS t statusMDS unsi
100. ed char drv_type unsigned short int drv_ver unsigned char inter unsigned char baud unsigned char dili unsigned char mtag unsigned char fcon unsigned char ftim unsigned char sema unsigned char ant unsigned char standby unsigned char anw mobyStatusU t typedef struct mobyStatusMDS_d mobyStatus_t status unsigned long int mds_no unsigned char mds_type unsigned long int strz unsigned short int ssmz unsigned short int mcod unsigned short int rbld unsigned char sleep time mobyStatusMDS t typedef union mobyErr d long error mobyStatus_t status mobyErr t definitions for moby_diagnose for MOBY U only define MOBY U MAXFUNC 33 typedef struct funcDesc_d unsigned char data 7 funcDesc_t typedef struct mobyDiagnoseCall_d mobyStatus_t status unsigned int num funcDesc_t functions MOBY_U_MAXFUNC mobyDiagnoseCall t define MOBY U MAXERR 233 typedef unsigned char errDesc_t typedef struct mobyDiagnoseErr_d mobyStatus_ t status unsigned int num errDesc_t error MOBY_U_MAXERR mobyDiagnoseErr t define MOBY U MAXMDS 24 typedef struct mdsDesc d unsigned char data 4 mdsDesc_t typedef struct mobyDiagnoseMDS d mobyStatus_ t status unsigned int num mdsDesc_t mds MOBY_U_MAXMDS mobyDiagnoseMDS t typedef struct mobyDiagnoseRepeat_d unsigned int num mobyDiagnoseRepeat t 114 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Header Files
101. ee chapter Notice With ASM 724 ASM 424 only a maximum of 234 bytes can be written with one telegram With ASM 824 a maximum of 192 bytes can be written with one telegram MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 4 Function moby_init mobyErr_t moby_init mobyHandle_t handle unsigned char setVal ulnt mdsLength HANDLE sync mobyErr_t err The moby_init function is used to initialize write the entire MDS with one byte the MDS located in the antenna field of the SLG SLA or SIM It is an unspecific initialization call handle mobyHandle_t Handle of the serial interface and the channel number setVal unsigned char 1 byte in hex format with which the entire MDS is to be written 00 hex to FF hex mdsLength ulnt Number of bytes to be deleted on the MDS For the number of bytes to be deleted length of the user data see the technical description HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice When the number of bytes to be deleted is less than the length of the user data of the MDS the memory of the MD
102. en only one MDS is located in the field and the read call is to be non specific data unsigned char Pointer to the buffer in which the data read from the OTP memory are to be stored The buffer must have a minimum length of 16 bytes sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram err mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter 3 7 1 MOBY API C Library 4 J31069 D0137 U001 A5 7618 87 MOBY API C Library 03 05 88 Notice The moby_s_readOTP command may only be sent to the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If the MDS with the identification number specified by the specific call is not located in zone 1 the command is terminated with an error If there is a non specific call and no MDS is located in zone 1 the command waits until an MDS enters zone 1 or the RESET command arrives If there is a non specific call and more than one MDS is located in zone 1 the command is terminated with an error Notice The 128 bits of user information are written to the MDS with the WRITE command Read accesses must request all 12
103. ent the warning notice representing the highest degree of danger will be used A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage Qualified The device system may only be set up and used in conjunction with this personnel documentation Commissioning and operation of a device system may only be performed by qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Trademarks All names identified by are registered trademarks of the Siemens AG The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner Copyright Siemens AG 2001 2002 2003 2005 All rights reserved Disclaimer of liability Passing on this document to third parties reproduction utilization and Although we have checked the contents of this manual for agreement revelation of its contents is not permitted without express permission with the actual hardware and software full agreement cannot be Violators shall be liable for damages All rights are reserved in particular guaranteed The information in this manual is checked at regular rights created by a patent grant or registration of a utility model or intervals and neces
104. er File 3964R H header file for the 3964R Lauf driver Version 4 40 14 June 2002 This header file has to be included into any program source code that intends to use the driver API LLLLLELTLLLTTATLTT LTT ALLL TATA LTT TAT TTT TAT TATA TTT TTT definition of the export and import interface ifdef 3964R TREIBER_ IMPL define DLLROUTINE _ declspec dllexport else define DLLROUTINE _ declspec dllimport endif define DLLDECL _ cdecl ifdef _ cplusplus define DLLROUTINE extern C else define DLLROUTINE extern endif include windows h Te ge EEL ELT IEEE A A E TLE LTE TE type definitions typedef signed short int comInt typedef comInt comHandle t typedef struct _devConfig_t int baud databit paritaet stopbit int prot int sswh swh zt qt to uew int empf send BOOL drop int priority devConfig t typedef devConfig t devConfig p typedef void CALLBACK comNotifCall int event int status comHandle t handle int userID LITTLTITLTTTTLT TT TATTLE TTT TTT TTA TTT interface for the 3964R driver mostly adopted from the ECCOM interface available for Win 3 1 Hif defined __ cplusplus extern C endif DLLROUTINE comInt DLLDECL ComOpen LPCSTR com_name int read_number int write number HWND hwnd DLLROUTINE comInt DLLDECL ComRead comHandle_t com_handle void FAR read_data int read_number long option
105. erial Interface Ethernet Interface x x x X X x x x X X X X X moby_status moby_statusU moby_diagnose moby_unexpect X x x Xx Function moby_ start mobyErr_tmoby_start mobyHandle_t handle mobyTypeee_t type BOOL eccON mobyParameters_t param HANDLE sync mobyErr_t err This function parameterizes and initializes an already opened MOBY device Among others a RESET telegram with or without parameter transfer is also sent to the SLG ASM or SIM Not until this telegram is concluded successfully or not is the interface ready for other telegrams When this function is to be called again after successful execution the moby_stop function must be executed first The parameters for the RESET telegrams are transferred with a union data structure see chapter 4 1 for MOBY_API H header file or chapter 4 3 for MOBY_API_T H header file Evaluation of the union data structure is based on a constant with which the MOBY type system is specified MOBY API C Library 4 J31069 D0137 U001 A5 7618 51 MOBY API C Library 03 05 Table 3 3 Constants for the MOBY type Constant MOBY Type Interface Commentary See Type Serial Ethernet Parameter MOBY_E MOBY_F MOBY_ or MOBY_la MOBY_ Ib MOBY_Ua SLG 7x on ASM 420 or SLA 7x on ASM 724 SLA 8x on ASM 824 SIM 41 SLG 4x on ASM 420 or SLG 4x on ASM 424 SIM 41 SLG 4x on ASM 420 or SLG 4x on ASM 424 SLG U92 When the op
106. es that XX1X XXXX the driver has detected a 1 bit error and corrected it The read or write data are okay MOBY API C Library 4 J31069 D0137 U001 A5 7618 137 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05 Table A 5 Status and error codes of ASM 424 724 824 Error Code Flashing LED Description Hex per Channel 40 64 Not an error message binary This bit is usually always set It is reserved for indication of the status X1XX XXXX of a 2nd battery on the MDS 80 Not an error message binary Battery voltage of the MDS has dropped below the threshold value 1XXX XXXX We recommend replacing the MDS immediately With MDS types with EEPROM this status bit is always set With SINUMERIK the battery message does not have the ID F in IDENTIFICATION To detect a weak battery the fnr field can be evaluated at some point in the total system MOBY API C Library 196 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B Programming the SLG U92 Based on the Operating System or 3964R Driver For whom is this appendix written This appendix is written for users who place their applications directly on the operating system or the 3964R driver level and do not use the MOBY API C library Additional information on the 3964R driver level is available from the user s guide 3964R protocol under Windows NT 4 0
107. f comment This interface is adopted from the ECCOM driver package available for Windows 3 1 However the calling semantics have changed slightly for some calls This is necessarry to accomodate the modified driver specification oanoaer OO oneOE N eli PIL PLC PEE TOLER LL BELD Error and status codes according to ECCOM define COM _OK 0x0000 define COM ST FREE 0x0000 define COM ST BUSY 0x0001 define COM ST SUCCESS 0x0003 define COM _ST_ERROR 0x8000 define COM ST_2MANY 0x8001 define COM ST NO CON 0x8002 define COM _ST_NO TRA 0x8004 define COM ST_2SMALL 0x8008 define COM ST_BCCERR 0x8010 define COM ST_TIMCON 0x8020 define COM ST TIMTRA 0x8040 define COM ST_TIMQUI 0x8080 define COM ST SCC BR 0x8100 define COM ST_SCC_PY 0x8200 define COM ST scc_ FR 0x8400 define COM ST SCC OR 0x8800 define COM_ST_SNDRCV 0x9000 define COM_ST_SYSERR 0xC000 define COM DLL ERROR OxA000 define COM HANDLE FALSE OxA002 define COM NO_MEMORY OxA003 define COM 2MANY OxA004 define COM _2SMALL OxA005 define COM DOS ERROR OxA006 define COM ALREADY OPEN OxA007 define COM NOT OPEN OxA008 define COM NO TIMER 0xA009 define COM_ERROR_WRITE_OLD OxA00A define COM _COM BUSY OxA00B define COM _ERROR_POSTMESSAGE OxAOO0C define COM CLOSE ERROR OxA00D define COM FREE ERROR OxAO0E define COM _CLFR_ ERROR OxAOOF define COM _UNKNOWN_ID 0xA010 define COM_UNKNOWN_EVENT 0xA011 define COM_OP
108. face error See chapter Notice The OTP memory has a length of 16 bytes 128 bits and can only be read once as a whole This means that the moby_read OTP function always reads 16 bytes The buffer for the read data must have a minimum length of 16 bytes Otherwise the memory area is overwritten MOBY API C Library 4 J31069 D0137 U001 A5 7618 73 MOBY API C Library 03 05 3 4 7 74 Function moby_writeOTP mobyErr_t moby_writeOTP mobyHandle_t handle unsigned char data HANDLE sync mobyErr_t err This function is used to write the OTP One Time Programmable memory once with a block of 16 bytes 128 bits handle mobyHandle_t Handle of the serial interface and the channel number data unsigned char Pointer to the buffer in which the data to be written to the OTP memory are stored The buffer must have a length of at least 16 bytes sync HANDLE Handle to synchronization with the response telegram Initialized Windows event which the application uses to wait for the response telegram err mobyErr_t Pointer to a structure in which the status byte of the response telegram and any error code and interface_errors are to be stored See chapter 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice The OTP memory has a length of 16 bytes 128 bits and can only be written once as a whole This means that the moby_write OTP function always writes 16 bytes MOB
109. generated MOBY API C Library 4 J31069 D0137 U001 A5 7618 77 MOBY API C Library 03 05 78 Notice The 128 bits of user information in the OTP memory are addressed with the start address 16 FFFO hex The 128 bits of user information are written to the MDS with the WRITE command All 128 bits of information must be requested with the GET call Notice With the SLG U92 with ASM 480 TCP IP a maximum of only 226 bytes MDS ID numbers and user data can be read with one telegram This means parameter length x 226 4 bunch size bunch size MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 10 Function moby_s_ write mobyErr_t moby_swrite mobyHandle_t handle ulnt idData ulnt mdsAddress unsigned char data ulnt length HANDLE sync mobyErr_t err You can use this function to specifically or non specifically write data to an MDS which is located in the antenna field of the SLG U92 e A specific call to write contains the identification number of the MDS More than one MDS may be located in the antenna field You can determine the ID number of the MDS with the GET function e A non specific call to write does not contain the identification number of the MDS Only one MDS may be located in the antenna field handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData ulnt Value from 20 to 232 1 Identification
110. gned char mode unsigned char cweek unsigned char year HANDLE sync mobyErr _t err moby _s_statusMDS mobyHandle_t handle uInt idData moby writeOTP mobyStatusMDS t statusMDS unsigned char mode unsigned char cweek unsigned char year HANDLE sync mobyErr t err mobyHandle_t handle unsigned char data HANDLE sync mobyErr_t err moby _s_writeOTP mobyHandle t handle uInt idData moby _readOTP moby _s_ readOTP moby _s_ copy unsigned char data HANDLE sync mobyErr _t err mobyHandle_t handle unsigned char data HANDLE sync mobyErr_t err mobyHandle _t handle uInt idData unsigned char data HANDLE sync mobyErr t err mobyHandle_t handle uInt idDatal int addri uInt idData2 int addr2 uInt len HANDLE sync mobyErr_t err Pea a GLEE TI SEMEL a EG EG A Eel gE Mob define define define define y channe s MOBY _CHANNEL1 MOBY _ CHANNEL2 MOBY _CHANNEL3 MOBY _CHANNEL4 MOBY API C Library 4 J31069 D0137 U001 A5 7618 BWNHEH 107 Header Files 03 05 define MOBY NOCHANNEL 0 A Moby types define MOBY I define MOBY Ia define MOBY Ib define MOBY F define MOBY E define MOBY L define MOBY Ua define MOBY Ub define MOBY Uc MOBY I with intervall reset MOBY I with extended reset MOBY U with small set of parameters MOBY U with large set of parameters MOBY U with multitag support
111. gth Binary value 1 to 244 Length of the user data to be read 16 Length of the OTP memory The READ command may only be used on the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If the call is non specific and there is more than one MDS in zone 1 the command is terminated with an error If the call is non specific and there is no MDS in zone 1 the command waits until an MDS moves into zone 1 or the RESET command arrives If the call is specific and the MDS with the specified MDS no is not located in zone 1 the command is terminated with an error Notice The 128 bits of user information in the OTP memory are addressed with the start address 16 FFFO hex The 128 bits of user information are written to the MDS with the WRITE command The read call must request all 128 bits of information MOBY API C Library 4 J31069 D0137 U001 A5 7618 175 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 1 1 4 GET Function 176 You can use the GET function to determine which MDS is located in the field At the same time you can read these data from this MDS Byte 0 1 2 3 4 5 6 Parameter 06 OC 00 mode address length Mode Binary value 0 Don t read data from MDS 1 Read data from MDS Address Binary value 0 Ifnodataon MDS 0 to maximum length of user data minus 1 Start address of the data to
112. hain is executed on this MDS When the MDS command or the command chain without the END command was executed on an MDS located in the antenna field and then another MDS enters the field the MDS command or command chain to be executed is terminated with error 1D hex This means that with a command chain each telegram is acknowledged with an error status Caution No check is made to determine whether OTP memory was addressed in a write command With automatic repetition each MDS would receive the same OTP memory content L UEB Function See appendix B 2 1 2 3 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 3 2 Acknowledgments Messages from the SLG U92 Telegram overview Telegram Header User Data Max of 251 Bytes Acknowledg ment message INIT 0 1 2 Status hex WRITE 3 to max of 253 User data hex READ ABL 02 00 Address Length Data MDS STATUS 12 0B 00 MDS no MDS type Sum of subframe accesses RESET Sum of search mode accesses x MCOD Remain batt SLG STATUS SLG status Status information SLG STATUS diagnosis Diagnostic information SLG STATUS diagnosis ll Diagnostic information SLG STATUS diagnosis III SET ANT END 02 REPEAT L UEB Startup ANW MELD ABL
113. he read data are stored in the buffer specified by the parameters idData and idLength These data do not become valid until the synchronization handle signals that the response telegram has arrived with the read data MOBY API C Library 4 J31069 D0137 U001 A5 7618 69 MOBY API C Library 03 05 3 4 3 70 Function moby_write mobyErr_tmoby_write mobyHandle_t handle uint mdsAddress unsigned char data ulnt length HANDLE sync mobyErr_t err The moby_write function is used to write the data to the MDS located in the antenna field of the SLG SLA or SIM It is an unspecific write access handle mobyHandle_t Handle of the serial interface and the channel number mdsAddress ulnt Start address on the MDS for the data to be written 20 0 up to maximum length of the user data minus 1 Address plus data length must be less than the end address on the MDS data unsigned char Pointer to the buffer in which the data to be written are stored length ulnt Number of bytes to be written gt 0 1 to maximum of 248 bytes sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error S
114. he structure in which the status byte of the e pone telegram with any error codes 2 rrors is to be stored see Return value gt 0 No error command executed lt 0 Interface error See chapter Notice The buffer contains the signal states of the digital outputs to be set and the related conditions The number and type of representation vary depending on the particular MOBY system See documentation 01 or 02 of your MOBY MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 6 Function moby_version mobyErr_t moby_version int major int minor The moby_version function is used to scan the version of the dynamic link library MOBY_API DLL or MOBY_API_T DLL The version number is returned in two parts the main number xx and the subnumber yy It is combined as xx yy major int Memory word for the value xx of the version number minor int Memory word for the value yy of the version number Return value gt 0 No error command executed lt 0 Interface error See chapter Example Version 1 0 appears as xx 1 and yy 0 MOBY API C Library 4 J31069 D0137 U001 A5 7618 93 MOBY API C Library 03 05 3 7 3 7 1 94 Function Errors Interface Error as Return Value The interface errors supplied as return values by the described functions are listed below e Errors directly from the MOBY_API or MOBY_API_T DLL e Errors from the 3964R driver only serial link to PC e Er
115. header Data format When not otherwise noted all numbers are specified in hex format Channel number CHN A 6 1 Byte 0 CHN of the telegram contains the channel on the ASM The channel is actually the read write device SLG or the read write antenna SLA e Channel number 0 Basic module of the ASM e Channel number 1 2 3 or 4 SLG 1 SLA 1 to SLG 4 SLA 4 Startup Telegram Byte 0 1 2 3 Com oe Too oF CHN 00 Hex Basic module of the ASM The startup telegram arrives as an automatic acknowledgment after the hardware starts up The CHN is 0 since it is only sent once by the total device and not by each channel MOBY API C Library 4 J31069 D0137 U001 A5 7618 127 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05 A 6 2 RESET Command Byte 0 1 2 3 4 5 6 CEN os 00 00 aera PARAM opion 1 7 6 5 4 3 2 1 0 TST_ON Time CLR_LED Res out Bit 7 6 5 4 3 2 1 0 ANWSTEU MOBY oper mode CHN 01 02 03 or 04 Hex SLG 1 SLA 1 to SLG 4 SLA 4 ABTA Setting of the scanning time for MOBY I Long Range with ASM 424 PARAM ANWSTEU 000 Operation without ANW control without ANW monitoring 001 Operation without ANW control with ANW monitoring 1 010 Operation with ANW control and ANW monitoring via the firmware 1 Operating modes with MDS F1xx MOBY F read only must always be parameterized with ANW monitoring 2 ANW control only applies to ASM 424 Do not us
116. hen a status query is still waiting to be answered are rejected with an error message Status information varies depending on the particular MOBY The data do not become valid until the synchronization handle signals receipt of the response telegram For content and meaning see documentation 01 to 05 of your MOBY or also appendix A 6 6 for ASM 424 724 824 MOBY API C Library 4 J31069 D0137 U001 A5 7618 61 MOBY API C Library 03 05 3 3 9 62 Function moby_statusU mobyErr_t moby_statusU mobyHandle_t handle mobyStatusU_t status HANDLE sync mobyErr_t err This function is used to poll the status of an SLG U92 handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface status mobyStatusU_t Pointer to the structure in which the status and diagnostic information of the response telegram is to be stored sync HANDLE Handle to synchronization with the response telegram Initialized Windows event which the application uses to wait for the response telegram err mobyErr_t Pointer to a structure in which the status byte of the response telegram and any error code and interface errors are to be stored See chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice Only one queued status telegram is permitted at a time All status queries which are issued at a time when a status query is still unanswered will be rejec
117. ial link to PC Use Close to conclude the dialog MOBY API C Library 18 4 J31069 D0137 U001 A5 7618 03 05 Installation Overwriting an existing C library 7 Overwrite or deinstall an existing MOBY API C library i Moby API with driver 3964R Welcome to the Moby API with driver 3964R Setup Wizard Select whether you want to repair or remove Moby API with driver 3964R Repair Moby API with driver 3964R C Remove Moby API with driver 3964R WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Frevious Einish Figure 2 6 Overwriting existing C library serial link to PC To overwrite the existing MOBY API C library select Repair MOBY API with driver 3964R and then start the procedure with Finish see figure 2 7 Notice Be sure to add the new header files 3964R H and MOBY_API H and the C library MOBY_API LIB to the development package MOBY API C Library 4 J31069 D0137 U001 A5 7618 19 Installation 03 05 8 Existing MOBY API C library is overwritten iz Moby API with driver 3964R Installing Moby API with driver 3964R Figure 2 7 Screen shown during installation serial link to PC The existing MOBY API C library is overwritten MOBY API C L
118. ibrary 20 4 J31069 D0137 U001 A5 7618 03 05 Installation 9 Overwriting of the existing MOBY API C library is complete i Moby API with driver 3964R Installation Complete ence EFEVIGUS Figure 2 8 Overwriting completed serial link to PC Use Close to conclude the dialog MOBY API C Library 4 J31069 D0137 U001 A5 7618 21 Installation 03 05 Deinstallation To deinstall the existing MOBY API C library select Remove MOBY API with driver 3964R see figure 2 6 and then start the procedure with Finish see figure 2 9 10 Deinstall existing MOBY API C library i Moby API with driver 3964R Removing Moby API with driver 39 D EIEVIGUs Figure 2 9 Screen during deinstallation serial link to PC MOBY API C Library 22 4 J31069 D0137 U001 A5 7618 03 05 Installation 11 Deinstallation of existing MOBY API C library is complete iz Moby API with driver 3964R Installation Complete Figure 2 10 Deinstallation is completed serial link to PC Use Close to conclude the dialog MOBY API C Library 4 J31069 D0137 U001 A5 7618 23 Installation 03 05 2 2 1 Adjusting the Registry Oddity of Windows 2000 Windows NT and Windows XP If the driver was installed by the administrator generator owner and a user wants the rights to the 3964R driver the following steps must be performed by the administrator generator owner 1 Start the REGEDT32 EXE program 2 Set the
119. interface with moby_stop and then close it with moby_close This procedure is illustrated graphically in figure 3 1 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library Figure 3 1 3 1 7 Interface moby_close opened moby_start Interface moby_read write ready and initialized moby_stop Serious error Function sequence when MOBY API is used Figure 3 1 also shows what happens when a serious communication error or an error of line monitoring occurs The moby_stop command is automatically given which returns the interface to a defined but inactive state Notice When an application is terminated externally e g with CRTL ALT DEL and the application is used by the MOBY API C library and has at least one channel open it may sometimes happen under Windows 95 98 that system resources are not enabled correctly This may cause problems when MOBY API programs are executed later If this happens start the system again Use of Several Communication Channels The MOBY API C library permits the use of several communication channels on one physical interface This can be done by repeated use of the moby_open command Make sure that all communication channels of a physical interface are to be opened by the same process i e by the same application MOBY API C Library 4 J31069 D0137 U001 A5 7618 47 MOBY API C Library 03 05 3 1 8 ERRx TXT Log File s Whe
120. ion is waiting for the response telegram err mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapte 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter MOBY API C Library 4 J31069 D0137 U001 A5 7618 75 MOBY API C Library 03 05 76 Notice The MOBY_s_read command may only be sent to the SLG U92 when no command is queued yet on the SLG U92 The antenna must be on Otherwise an error message is generated The command is terminated with an error if the MDS with the specified identification number that is specifically called is not located in zone 1 If no MDS is located in zone 1 and a non specific call occurs the command waits until an MDS moves into zone 1 or the RESET command arrives If more than one MDS is located in zone 1 when a non specific call arrives the command is terminated with an error Notice The data that were read are stored in the buffer specified by the data and length parameters These data do not become valid until the synchronization handle signals that the response telegram has arrived with the read data Notice With SLG U92 with ASM 480 TCP IP a maximum of only 228 bytes can be read with one telegram MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 9 Function moby_s_getID mobyErr_t moby_sget
121. is considered interrupted The MOBY DLL closes the connection A queued telegram is terminated with an error When no telegrams are queued the error does not occur until the next telegram Before communication can be resumed the application must start the connection again with moby_open and moby_start Errors Telegrams from the SLG ASM or SIM may sometimes have errors or not be completely received Moby_stop is then called implicitly i e use of the interface is blocked and all waiting jobs are terminated with an error message Before the interface can be used again moby_start must be executed i e a RESET of the SLG ASM or SIM Notice All potentially affected interfaces are blocked when an error cannot be definitely related to an open interface e g hardware error on an ASM 824 724 424 channel Notice If Windows exceeds the monitoring time during the sending procedure an unexpected telegram may occur depending on where the telegram was interrupted The callback routine will report this telegram if you have called the moby_unexpect function Ignore the telegram Opening Using and Closing Interfaces Before an SLG ASM or SIM MOBY device can be addressed with MOBY API the appropriate interface must be opened and initialized This is done with the moby_open and moby_ start commands The interface can then be accessed with read and write commands Before the end of the program the programmer must deactivate the
122. ividual presentations are shown in hexadecimal hex format MDS Functions e You can use the MDS functions INIT READ and WRITE to read or write data to and from the MDS e You can use the GET function to find out which MDS is located in the field You can also read data from this MDS at the same time e You can use the COPY function to copy data You can copy one data area or the entire contents of a data carrier from one MDS to another e You can use the MDS STATUS function to query status and diagnostic data from an MDS MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 1 1 1 INIT Function You can use the INIT function to non specifically or specifically initialize with a bit pattern an MDS that is located in the antenna field of the SLG U92 e An initialization call is non specific when the call does not include the identification number of the MDS Only one MDS may be located in the antenna field e An initialization call is specific when the call includes the identification number of the MDS More than one MDS may be located in the antenna field You can determine the identification number of the MDS with the GET function Byte 0 1 2 3 to 6 7 8 9 10 Parameter OA 03 00 MDSno date 00 length MDS no Binary value 0 When an MDS is located in the antenna field and a non specific initial
123. ization call is to be executed Value 2 to 22 1 MDS no of the MDS that is to be initialized Date Binary value Bit pattern 00 hex to FF hex with which the data carrier is to be initialized written Length Binary value 32768 Length in bytes of the data memories MDS U524 MDS U525 and MDS U589 2048 Length in bytes of data memory MDS U313 and MDS U315 The INIT command may only be used on the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If the call is non specific and there is more than one MDS in zone 1 the command is terminated with an error If the call is non specific and there is no MDS in zone 1 the command waits until an MDS moves into zone 1 or the RESET command arrives If the call is specific and the MDS with the specified MDS no is not located in zone 1 the command is terminated with an error MOBY API C Library 4 J31069 D0137 U001 A5 7618 173 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 1 1 2 WRITE Function You can use the WRITE function to non specifically or specifically write data to an MDS that is located in the antenna field of the SLG U92 e A write call is non specific when the call does not include the identification number of the MDS Only one MDS may be located in the antenna field e A write call is specific when the call includes the identification number of the MDS
124. lave Character timeout ms C Lauf 220 Maximum number of repetitions due to a NAK negative Interface parameters send initiation repeats E acknowledge or parity error send repeats 3 Baud rate 3600 Baud 7 Uptions for the 23644 Slave prateco gt Maximum number of repetitions of an STX telegram start when Data bits communication partner doesn t 7Bits BBits answer Laur parameters Stop bits aS ee 2400 to 115200 Baud depending on o s Tingout val 200 ee ASM SLG or SIM see table 2 1 Parity _ r Default parameters for the driver C no parity res Maximum length is 255 bytes C Even pudii 255 7 see table 2 1 Odd Receive buffer 255 Discard conflict teleqranis Reset parameters to the values which were valid when the configuration program was called MV Apply configuration immediately reopen port if necessary Cancel Reset Default Reset parameters to the original data specified in the 3964R standard Figure 2 14 Dialog for configuration of the 3964R protocol MOBY API C Library 4 J31069 D0137 U001 A5 7618 27 Installation 03 05 Notice With MOBY U the standard parameterization of Acknowledgement timeout is 150 msec and Character timeout is 50 msec Notice If the checkbox Apply configuration immediately is checked all data changes are applied immediately in the configuration even when the port need
125. leted length of the user data see the technical description sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram err mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes rface errors is to be stored see 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapte MOBY API C Library 4 J31069 D0137 U001 A5 7618 81 MOBY API C Library 03 05 Notice The MOBY_s_init command may only be sent to the SLG U92 when no command is queued yet on the SLG U92 The antenna must be on Otherwise an error message is generated The command is terminated with an error if the MDS with the specified identification number that is specifically called is not located in zone 1 If no MDS is located in zone 1 and a non specific call occurs the command waits until an MDS moves into zone 1 or the RESET command arrives If there is more than one MDS in zone 1 and a non specific call occurs the command is terminated with an error MOBY API C Library 82 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 12 Function moby_s_ copy mobyErr_tmoby_s copy mobyHandle_t handle ulnt idData1 ulnt addr ulnt idData2 ulnt addr2 ulnt len HANDLE sync mobyErr_t err You can specifically copy data with this function One data area or
126. ltitag Processing Version 3 B 4 1 Telegrams to the SLG U92 MDS functions e INIT e WRITE e READ e GET e COPY e MDS STATUS System functions e RESET e SLG STATUS e SET ANT e END e REPEAT e L UEB Initialize MDS Write data block Read data block Get MDS Copy data from MDS 1 to MDS 2 MDS status diagnosis Reset SLG SLG status diagnosis Turn antenna on off End communication with MDS Repeat last command Line monitoring You can use the RESET command to reset the SLG U92 to a defined state By setting the parameters you can specify the system behavior of the SLG U92 MOBY API C Library 4 J31069 D0137 U001 A5 7618 171 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 Telegram Function Telegram overview Telegram Header 0 1 2 User Data Max of 251 Bytes 3 to max of 253 User data ABL 01 00 MDS no address length MDS no mode address address 10 07 00 MDSno 1 address1 length MDS no 2 address2 MDS no mode standby param 00 00 mode mode MDS no mode B 4 1 1 172 AB Telegram length in bytes without the AB byte ABL Variable telegram length in bytes without the AB byte depending on the length parameter 5 length Notice The data in the telegram overview and the following ind
127. minated and started again Depending on the CPU load and data memory accesses this may affect communication This means that the above times are exceeded To bypass or minimize this problem the thread priority for communication is set to 2 when the MOBY API C interface is installed Thread priority 2 means Maximum priority only during communication This setting is made for every COM interface used by the 3964R driver before the COM interface is opened If you reset the thread priority to its original value or you want to change it make the setting in the registry with the following key HKEY_LOCAL_MACHINE Software Siemens 74 1 3964r COMx ThreadPriority MOBY API C Library 4 J31069 D0137 U001 A5 7618 29 Installation 03 05 2 3 Installation of the MOBY API C Library for Link to Ethernet After the Windows installation package mobyapi_t msi starts you are guided through installation 1 Starting the mobyapi_t msi package The first time the C library is installed the screen for activating the C library installation figure appears Otherwise the screen for overwriting and de installing an existing MOBY API C library figure 2 20 appears Notice The MOBY API C library should never be manually installed or de installed either partially or completely This might cause problems during the installation or de installation with mobyapi_t msi New installation 2 Activating installation of the C library ji MOBY API
128. mobyDiagnoseRepeat t typedef union mobyDiagnose d mobyDiagnoseCall _t diagCall mobyDiagnoseErr t diagErr mobyDiagnoseMDS t diagMDS mobyDiagnoseRepeat_t diagRepeat mobyDiagnose t A foc tran sn sete Boe era Sela E a ete hth te he AAs tens eg BE n ieee hs ahah Ga Nie T parameters for MOBY I without multi channel support typedef struct mobyReset_d information to set read LEDs BOOL red green TxD RxD setLED information to set read driver BOOL dialogOn moreEC timeout eeprom anwControl setTreiber bit field for the DIL switches unsigned char dilSwitch mobyReset t Y typedef struct mobyInterval d short int timebase short int timeval BOOL dialogon BOOL mobyV_On 104 scanFlag mobyV_On MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Header Files mobyInterval_t Hl n Meera BS aE Ne Deletes ate MM ae ct cn Teenie by again aa a ses Sa on ee parameters for MOBY with multi channel support typedef struct mobyChannelasm_abta_f d unsigned char timeval 6 unsigned char timebase BD mobyChannelasm_abta f t typedef union moby channelasm_abta_d unsigned char raw mobyChannelasm_abta_f t fields mobyChannelasm_abta_t typedef struct mobyChannelasm_ param f d unsigned char mode 3 a4 unsigned char res 1 unsigned char anw 3 mobyChannelasm param f t typedef union mobyChannelasm_param_d unsigned char raw mobyChannelasm param f_t fields
129. moby_read mobyErr_tmoby_read mobyHandle_t handle ulnt mdsAddress unsigned char data ulnt length HANDLE sync mobyErr_t err The moby_read function is used to read data from the MDS located in the antenna field of the SLG SLA or SIM It is an unspecific read call since the MDS cannot be identified by an ID number handle mobyHandle_t Handle of the serial interface and the channel number mdsAddress_ ulnt Start address of the data to be read from the MDS 20 0 to maximum length of the user data minus 1 The address plus the data length must be less than the end address on the MDS data unsigned char Pointer to the buffer in which the read data are to be stored length ulnt Number of bytes to be read gt 0 1 to maximum of 248 bytes sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice The read data are stored in the buffer specified by the data and length parameters These data do not become valid until the synchronization handle signals that the response telegram has arrived with the read data With ASM 724 ASM 424 only a maximum of 234 bytes can
130. n the application with TCP IP is used the system generates an ERRx TXT log file with a maximum length of 7 kbytes for each connection i e communication channel x stands for the channel number The log file s is are stored under the path from which the application was called The log file contains internal system diagnostic data MOBY API C Library 48 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 2 Interface Functions The interface functions moby_open and moby_close open and close the communication channel for communication via e the serial interface or e the Ethernet interface At this time the Ethernet interface can only be used for MOBY U with the SLG U92 as MOBY type MOBY_Uc see chapter with MOBY U commands for single tag or multitag operation 3 2 1 Function moby_open for the Serial Interface mobyErr_tmoby_open char comStr int channel mobyHandle_t handle This function opens the specified MOBY device with the help of the driver If the command is concluded successfully the handle parameter is used to return a handle to the opened MOBY device This handle must be included with all subsequent calls which access this device Do not forget that an opened MOBY device must be parameterized and initialized beforehand with moby_start comStr char Character string with the name of the serial interface COM1 COM2 COM3 or COM4 channel int Channel number under which the SLG SIM or SLA is addres
131. nce the MDS is not identified by the ID number Byte 0 1 2 3 4 5 Parameter 05 02 00 Address Length address Binary value 0 to maximum length of user data minus 1 Start address of the data to be read from the MDS The address plus data length must be less than the end address 16 FFFO hex Start address of the OTP memory length Binary value 1 to 248 Length of the user data to be read Start address length must be less than the value of the memory length of the MDS in bytes minus 1 16 Length of the OTP memory The READ command may only be used for the SLG U92 and then only when no command is queued on the SLG U92 The antenna must be on Otherwise an error message is generated When more than one MDS is located in zone 1 the command is terminated with an error When no MDS is located in zone 1 the command waits until an MDS enters zone 1 or a RESET command arrives Notice The 128 bits of user information in the OTP memory are addressed with the start address 16 FFFO hex The 128 bits of user information are written to the MDS with the WRITE command With the READ command all 128 bits of information must be requested at one time MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 2 1 2 B 2 1 2 1 System Functions RESET Function The RESET command is used to reset the SLG U92 to a defined st
132. nds SF BF red Continuously on during startup Off when telegram is correctly received or sent Flashes once to twice per second when a send or receive error occurs telegram could not be transmitted in acc w 3964R protocol A 4 General Communication Procedure The ASM will not accept a command unless the previous command has been concluded The only exceptions are the RESET and status commands These two commands may occur simultaneously RESET and status commands are processed immediately Notice When two status commands are sent in succession but there is no acknowledgment response message from the first command only one acknowledgment for the last status command is output With the RESET command you should always wait for the acknowledgment before sending a new command A 5 Overview of Commands Table A 2 List of the commands RESET Resets both the active command and all other unprocessed commands in the buffer of the affected channel command termination Default setting of the ASM mode In detail e Operation with or without ANW or presence control e MOBY operating mode E F or I Read data from MDS 40 with ECC Write data to MDS 41 with ECC Initialize data memory 1A with ECC STATUS 0 Status query of ASM e Presence Command active e Status of ASM 50 51 18 1 MOBY API C Library 4 J31069 D0137 U001 A5 7618 125 Description of Communication to the ASM 424 724 824 with 3964R Protocol 03 05
133. ne MDS in zone 1 and a non specific call occurs the command is terminated with an error Notice With the SLG U92 with ASM 480 TCP IP a maximum of only 228 bytes can be written with one telegram MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 11 Function moby_s_ init mobyErr_t moby_sinit mobyHandle_t handle ulnt idData unsigned char setVal ulnt mdsLength HANDLE sync mobyErr_t err You can use this function to specifically or non specifically initialize an MDS with a bit pattern The MDS is located in the antenna field of the SLG U92 e An initialization call is specific when the call contains the identification number of the MDS Several MDSs may be located in the antenna field You can determine the identification number of the MDS with the GET function e An initialization call is non specific when the call does not contain the identification number of the MDS Only one MDS may be located in the antenna field handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData ulnt Value from 20 to 232 1 Identification number of the MDS When an MDS is located in the field and a non specific initialization call is to be performed setVal unsigned char 1 byte in hex format with which the entire MDS is to be written 00 hex to FF hex mdsLength ulnt Number of bytes on the MDS to be deleted For the number of bytes to be de
134. nents are usually equipped with physical interfaces RS 232 for short cables and RS 422 for long cables The protocol is always 3964R See appendix C 1 2 1 MOBY Systems for Serial Connection Table 1 1 Components which can be run with MOBY API with serial link to PC MOBY Product Family Interface Documentation MOBY E ASM 420 with SLG 7x ASM 424 with SLG 7x one to four SLG 7x on one ASM 424 ASM 724 with SLA 71 one to four SLA 71 on one ASM 724 MOBY F ASM 824 with SLA 81 one to four SLA 81 on one ASM 824 MOBY ASM 420 with SLG 4x without filehandler ASM 424 with SLG 4x one to four SLG 4x on one ASM 424 SIM 41 MOBY U without filehandler MOBY API C Library 6 4 J31069 D0137 U001 A5 7618 03 05 Introduction 1 2 2 C library MOBY API for Serial Link to PC The MOBY API C library for user specific MOBY applications runs under Windows 98 NT 4 0 2000 XP It implements and runs MOBY applications from the following components e C library MOBY_API LIB e MOBY header file MOBY_API H e Dynamic link library MOBY_API DLL e 3964R driver 3964R DLL e Configuration program for 3964R CPL3964R CPL e 3964R header file 3964R H e Sample application Executable EXAMPLE EXE Source code EXAMPLE CPP The read write devices SLG read write antennas SLA and the serial interface modules SIM are controlled via the serial interface by transmitting structured telegrams with the 3964R protocol Th
135. nsicht Sicherheit Optionen Fenster HKEY_LOCAL_MACHINE auf lokalem Computer Of HKEY_LOCAL_MACHINE HARDWARE SAM amp SECURITY SOFTWARE Registrierungsschlusselberechtigungen x Begistrierungsschllissel Siemens 741 Besitzer FILIEE eToys lms IV Berecht Namen anzeigen von GB DE_FTH_W3004 z Name A amp D SE MI Gruppe 4 A amp D SE MI Gruppe B A amp D SE MI Gruppe C A amp D SE MI Gruppe D A amp D SE MI Gruppe E A amp D SE MI Gruppe F A amp D SE MI Gruppe G A amp D SE MI Gruppe H e n Benutzer anzeigen HMitalieder Suchen Secure Siemens amp Siemens E Siemens Figure 2 13 Benutzer und Gruppen hinzuf gen screen MOBY API C Library 26 4 J31069 D0137 U001 A5 7618 03 05 Installation 2 2 2 Configuration of the 3964R Driver The 3964R driver is configured with the CPL3964R CPL configuration program see figure 2 14 It must be called under the system control of Windows The following parameters must be set as standard values with the configuration program e Data bits 8 e Stop bits 1 e Parity Odd e Send buffer 255 e Receive buffer 255 e Discard conflict telegrams V if 3964R driver is slave Configuration of the 3964R and the Lauf protocol parameters x Configuration of port COM1 Interface COM 1 to COM 4 Protocol 3964A parameters Master or slave depending on 22 1 3964R Master Sea N ms ASM SLG or SIM see table 2 1 C 3964R S
136. nt major int minor DLLROUTINE mobyErr_t DLLDECL moby _s_ end mobyHandle_ t handle uInt idData unsigned char mode HANDLE sync mobyErr _t err DLLROUTINE mobyErr_t DLLDECL moby _setANT mobyHandle t handle unsigned char mode HANDLE sync mobyErr _t err DLLROUTINE mobyErr_t DLLDECL moby _s_statusMDS mobyHandle t handle uInt idData mobyStatusMDS t statusMDS unsigned char mode unsigned char cweek unsigned char year HANDLE sync mobyErr t err DLLROUTINE mobyErr_t DLLDECL moby _s_writeOTP mobyHandle_t handle uInt idData unsigned char data HANDLE sync mobyErr t err DLLROUTINE mobyErr_t DLLDECL moby _s_readOTP mobyHandle_t handle uInt idData unsigned char data HANDLE sync mobyErr _t err ROUTINE mobyErr_t DLLDECL moby_s_copy mobyHandle t handle uInt idDatal int addr1l uInt idData2 int addr2 uInt len HANDLE sync mobyErr _t err iw if defined __ cplusplus endif Sy its epee On LILLIA LILLIE LILA LIAL ISR LIEU LILI SAIL lel de Moby channels define MOBY CHANNEL1 define MOBY CHANNEL2 define MOBY CHANNEL3 define MOBY CHANNEL4 PWN define MOBY NOCHANNEL 0 VUIA LININ AAL AANA CIANA LALALALA ANALIMA TATA NAAALALA AAAA LALA I AAA TT Moby types define MOBY Ua 5 MOBY U with small set of parameters define MOBY Ub 6 MOBY U with large set of parameters define MOBY
137. oby_s_ end mobyErr_t moby_s end mobyHandle_t handle ulnt idData unsigned char mode HANDLE sync mobyErr_t err This function is used to specifically or non specifically ignore the standby time parameterized in the RESET telegram of an MDS that is in the antenna field of the SLG U92 e A specific read call means that the call is sent with the ID number of the MDS More than one MDS may be located in the antenna field You can determine the ID number of the MDS with the GET function e A non specific read call means that the call is sent without the ID number of the MDS Only one MDS may be located in the antenna field handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData ulnt Value of 20 to 232 1 ID number of MDS Only one MDS is located in the field and a non specific read call is to be used unsigned char Processing of the MDS is finished and the parameterized standby time should be ignored No more communication is to take place with this MDS The MDS will exit the field of the SLG The SLG removes the MDS from the processing list but keeps the MDS in the presence list until the MDS has actually exited the field of the SLG There is an MDS processing pause and the parameterized standby time is to be ignored The MDS hasn t left the field of the SLG yet At least one further communication with the MDS is to take place The SLG continues to keep the MDS
138. ocol with which it is addressed on the network The IP address may only be present once in the network It must be parameterized on the ASM 480 In the user application on the PC the IP address is specified in the moby_open function as a character string during the establishment of the connection The IP address always consists of 32 bits and is presented in decimal format value range from 0 to 255 It is thus a character string with four number values in ASCII format each separated by a period The subnet mask is required to determine the network The subnet mask is similar to the IP address It consists of four numbers separated by a period value range from 0 to 255 Example IP address 157 163 170 12 subnet mask 255 255 0 0 Application Application PC client ASM 480 server Transmission Control Protocol Transmission Control Protocol TCP TCP Internet Protocol IP Internet Protocol IP IP address IP address 157 163 170 12 157 163 170 13 Ethernet TCP IP protocol Figure 2 25 TCP IP connection MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Installation When communication is network overlapping between different network addresses the IP address of the standard gateway must also be parameterized on the ASM 480 Without this information IP functionality remains limited to the local subnetwork TCP IP configuration Setting the IP address subnetwork mask and IP address of the standard ga
139. ot equal 00 hex Byte 0 1 2 3 to6 Parameter 06 01 status MDS no Status Bit pattern For status see appendix B 6 MDS no Binary value Value 2 to 2 1 MDS no ofthe not written MDS specific write call with error 0 Non specific write call with error MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 2 1 3 READ Acknowledgment Acknowledgment without error status 00 hex Byte 0 1 2 3 to6 7 8 9 10 to max of 253 Parameter ABL 02 status MDS no address length data ABL Binary value 1 to 253 Telegram length in bytes without the AB byte Status Bit pattern 00 hex MDS no Binary value Value 2 to 2 1 MDS no of the read MDS Address Binary value 0 to value Memory length in bytes minus 1 16 FFFO hex after reading the OTP memory Length Binary value 1 to 244 Length of the read user data Data Binary information User data read from the MDS Acknowledgment with error status not equal 00 hex Byte 0 1 2 3 to6 Parameter 06 01 status MDS no Status Bit pattern For status see appendix B 6 MDS no Binary value Value 2 to 2 4 MDS no of the not read MDS specific read call with error 0 Non specific read call with error MOBY API C Library 4 J31069 D0137 U001 A5 7618 187 Programming the SLG U92 Based on the Operating System or 396
140. ox switches The 1st proximity switch turns the field on and the 2nd turns the field off MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver ftim Binary value Sema Binary value MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 hex Mode 4 SLG synchronization see MOBY U manual for configuration installation and service When two proximity switches exist and one proximity switch is parameterized the field is automatically turned off when the oe proximity switch does not switch within this proximity switch time If the 2 proximity switch does not exist one proximity switch time must be parameterized After this time the field is automatically turned off Proximity switch time field ON time 0 No proximity time see proximity switch mode 1 to 255 1 to 255 seconds Semaphore control synchronization with SLG 01 hex Yes 02 hex No 167 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 3 2 2 3 168 ANT Standby Binary value ANW Binary value Binary value Status of antenna 01 hex Antenna on 02 hex Antenna off Time after an executed MDS command for standby of MDS 0 No standby After each time communication with the MDS occurs the MDS goes to sleep The MDS cannot be read or written until after the sleep time 1 to 200 7 msec to 1400 msec Presence see RESET
141. path Siemens 741 in the HKEY_LOCAL_ MACHINE screen see figu re 2 11 i Registrierungseditor Registrierung Bearbeiten Baum Ansicht Optionen Fenster HKEY_LOCAL_MACHINE auf lokalem Computer HKEY_LOCAL_MACHINE HARDWARE Gi SAM amp SECURITY GP SOFTWARE Hame a Figure 2 11 The HKEY_LOCAL_MACHINE screen MOBY API C Library 24 4 J31069 D0137 U001 A5 7618 03 05 Installation 3 Select Sicherheit in the menu bar see figure 2 11 The Registrierungsschlusselberechtigungen screen appears In this screen activate the option Berechtigungen and select the user for whom the rights are to be added see figure 2 12 Registrierungseditor Registrierung Bearbeiten Baum Ansicht Sicherheit Optionen Fenster HKEY_LOCAL MACHINE auf lokalem Computer of xi HKEY_LOCAL_MACHINE HARDWARE SAM a SECURITY SOFTWARE Registrierungsschlusselberechtigungen Redgistrierungsschlissel Siemens 741 Besitzer FU164731 WYollzugriff Vollzuariff Beschrankter Zugriff Vollzuaritf Zuariffsart Volzugritt ei Abbrechen Hinzuf gen Entfemen Hilfe Mi M inm Haseman 4 Figure 2 12 Registrierungsschlusselberechtigungen screen MOBY API C Library 4 J31069 D0137 U001 A5 7618 25 Installation 03 05 4 Click the Hinzuflgen button In the screen which appears change Zugriffsart to Vollzugriff see figure Then close all screens with OK Reaistrierung Bearbeiten Baum A
142. pi_t msi with Windows NT or Windows 98 is not indicated as type Windows Installer Package the Windows Installer must be activated The installation of the C library MOBY API is executed in its own installation sector depending on the link interface version e Installation for serial link to PC mobyapi msi e Installation for link to Ethernet mobyapi_t msi 2 2 Installation of the C Library MOBY API for Serial Link to PC After starting the Windows installation package mobyapi msi you will be guided through installation 1 Start the mobyapi msi package The first time the C library is installed the Welcome to the MOBY API screen appears see figure 2 1 Otherwise the Select whether you want to repair or remove MOBY API screen is opened see figure 2 6 Notice The MOBY API C library should never be partially or completely installed de installed manually This may cause problems during installation deinstallation with mobyapi msi MOBY API C Library 4 J31069 D0137 U001 A5 7618 13 Installation 03 05 New installation 2 Activate the installation of the C library i Moby API with driver 3964R Welcome to the Moby API with driver 3964R Setup Wizard Figure 2 1 Activating installation of the C library serial link to PC Click Next to activate installation The screen Select Installation Folder appears see figure 2 2 Cancel terminates installation with previous confirmation
143. pplication in Source Code for Link to Ethernet A sample application in source code TEST CPP VC 6 0 is available for a simple READ application for the SLG U92 on the ASM 480 Before the application is compiled the IP address 157 163 170 2 predefined in TEST CPP must be adjusted to the actual IP address Example code for MOBY API T Simple open start read stop close stop sequence include lt stdlib h gt include lt stdio h gt include lt windows h gt include moby _api_t h mobyHandle _t comdev1l typedef DWORD MDS address typedef unsigned char zeichen callback routine for unexpected telegramms we don t expect any gt i e error gt i e stop communication void _ stdcall unex_cb unsigned char cl unsigned char c2 unsigned char c3 printf Got unexpected telegramm n moby _stop comdev1 start and synchronize read request int MOBY_read int comdev FAR void data MDS address MDS int length void CALLBACK status int HANDLE sync mobyErr t errl err2 unsigned int mdsID 2 unsigned int adress 0 mdsID 0 0 sync CreateEvent NULL FALSE FALSE NULL int len errl moby _s_ read comdev amp mdsID 0 adress zeichen data length sync amp err2 if errl error MOBY_OK WaitForSingleObject sync INFINITE errl error volatile int err2 error CloseHandle sync return errl error start and synchronize reset start int MOBY reset
144. r GET function with mode 1 with MDS data and at least 1 MDS in the antenna field zone 1 Byte 0 1 2 3 4 to 3 4 n Parameter ABL OC status Number of 1st MDS no nth MDS no MDSs 4 4 nto5 4 n 6 4 n address length 7 4 n to 6 4 n length n data MDS 1 data MDS n ABL Binary value Telegram length in bytes without the AB byte 14to6 4 n 1 lt n lt 12 length n n Number of MDSs in the antenna field zone 1 4 bytes for each MDS no Status Bit pattern 00 hex Number of Binary value Oto 12 Number of MDSs in the antenna MDSs field zone 1 n 1st MDS no Binary value Value 2 to 2 1 MDS no of the 1st MDS nth MDS no Binary value Value 2 to 2 1 MDS no of the nth MDS Address Binary value See GET function appendix B 4 1 1 4 Length Binary value See GET function appendix B 4 1 1 4 Data MDS 1 Binary information User data read from 1st MDS Data MDS n Binary information User data read from nth MDS Acknowledgment with error status not equal 00 hex Byte 0 1 2 Parameter 02 OC status Status Bit pattern For status see appendix B 6 MOBY API C Library 4 J31069 D0137 U001 A5 7618 189 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 4 2 1 5 COPY Acknowledgment Acknowledgment without error status 00 hex Byte 0 1 2 3 to 6 7 to 10 Parameter OA 07 status MDS no 1 MDS no 2 Status Bit pa
145. racters in telegram Running command terminated by RESET command 197 3964R Procedure 03 05 C 3964R Procedure The 3964R procedure offers secure data transmission with a point to point connection Secure data transmission is ensured with block transmission using parity block check character BCC and receipt acknowledgment A data block may contain all characters from 00 hex to FF hex Character frame Transmission Asynchronous Baud rate 9600 19200 38400 57600 115200 Baud Data bits 8 Parity Odd Stop bit 1 Control character in the 3964R procedure Table C 1 Control characters in the 3964R procedure Character Code Hex Meaning STX 02 Initialization of a send job request to send DLE ETX 10 03 End of a transmission block DLE 10 Ready to receive or DLE doubling in data flow NAK 15 Negative response message for block check error or unrecognized start character DLE DLE 10 10 DLE doubling in data block Is used when the value 10 hex appears in the data flow Block transmission procedure Sender Sender ae tz Monitoring time on ASM 1st byte of user data 300 msec 2nd byte of user data tz Last byte of user data DLE ETX BCC gt DLE Data block ae MOBY API C Library 199 4 J31069 D0137 U001 A5 7618 03 05 Terms Abbreviations List of Literature D Terms Abbreviations List of Literature D 1 Terms Abbreviations ASM CHN DI
146. river TCP IP E ioj x Confirm Installation L Axl yx E7 The installer is ready to install MOBY API with driver TCP IP on your computer Click Next to start the installation Cancel Previous Figure 2 18 Execution of installation link to Ethernet With Next the MOBY API software is stored for the preparation of applications under the following subdirectories within the chosen directory example EXAMPLE ZIP Sample applications include MOBY_API_T H Header file for user applications lib MOBY_API_T LIB C library for user applications The DLL of the dynamic link library MOBY_API_T is copied to the following directory depending on which Windows system you are using Windows NT 4 0 C AWINNT SYSTEM32 Windows 98 C WIN98 SYSTEM Windows 2000 C AWIN2000 SYSTEM32 Windows XP CAWINNT SYSTEM32 MOBY API C Library 4 J31069 D0137 U001 A5 7618 33 Installation 03 05 34 6 Procedure for installing an existing MOBY API C library is concluded ji MOBY API with driver TCP IP Installation Complete Figure 2 19 Installation complete link to Ethernet Close concludes the dialog MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Installation Overwriting an existing C library 7 Overwriting or de installing an existing MOBY API C library ii MOBY API with driver TCP IP Welcome to the MOBY API with driver TCP IP Setup Wizard Select whether you want to repair or remove MOBY AP
147. ror status not equal 00 hex Byte 0 1 2 3 4 5 Parameter 05 02 Status Address Length Status Bit pattern For status see appendix B 6 Address Binary value Start address on the MDS as specified in the function call Length Binary value Length of the data to be read from the MDS as specified in the function call MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 2 2 2 B 2 2 2 1 B 2 2 2 2 Acknowledgments to System Functions RESET Acknowledgment Byte 0 1 2 3 4 5 Parameter 05 00 Status FW 00 status U Byte VersH VersL Status Bit pattern For status see appendix B 6 VersH Binary value 00 hex to FF hex Firmware status high VersL Binary value 00 hex to FF hex Firmware status low Example 01 high and OA low version 1 10 SLG STATUS Acknowledgment SLG Status Acknowledgment without error status 00 hex Byte 0 1 2 3 4 5 67 8 9 10 11 Parameter 1B 04 Status Sinfo HW HW V Ur V FW FW V 12 1314 15 16 17 18 19 20 21 22 TR TR V ISS Baud 00 0O 00 dili mtag fcon 23 24 25 26 27 ftim Sema ANT Standby ANW Status Bit pattern 00 hex S info Binary value 01 hex SLG status mode HW ASCII HW version HW V Binary value HW version 00 hex to FF hex 00 hex to F
148. rors from the SLG ASM with SLG or SLA or SIM The errors from the 3964R driver are divided into two classes e Status error messages These messages signal status errors which occur while telegrams are being transferred They are usually related to the interface or local system resources e System error messages These messages indicate that call functions malfunctioned They usually mean a fatal error in the system and or the configuration settings The return value is type long integer and is always negative Its layout is shown below Return value Error code OR error block OR error number The values of error code error block and error number are OR linked and may assume the following values Error code 0x80 00 00 00 Error block 0x1 00 00 Error directly from the MOBY_API DLL 0x2 00 00 Error from the 3964R driver 0x3 00 00 Error from the SLG ASM with SLG or SLA or SIM MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library Error numbers e MOBY_API or MOBY_API_T 0x00 00 0x00 01 0x00 02 0x00 03 0x00 04 0x00 05 0x00 06 0x00 07 0x00 08 0x00 09 0x00 0A 0x00 OB 0x00 0C 0x00 0D 0x00 OE 0x00 OF 0x00 10 0x00 11 0x00 12 0x00 13 0x00 14 0x00 15 Fatal error Wrong device handle Wrong parameter Wrong unsuitable response telegram Response telegram has wrong length Match buffer full Wrong MDS type No other handle available Windows system error Command terminated
149. s complete Close concludes the dialog MOBY API C Library 4 J31069 D0137 U001 A5 7618 37 Installation 03 05 De installation When the existing MOBY API C library is to be de installed select Remove MOBY API with driver TCP IP see figure 2 20 and then start the procedure with Finish see figure 2 23 10 De installation of an existing MOBY API C library fi MOBY API with driver TCP IP Removing MOBY API with driver T ee MOBY API with driver TCP IP is being removed Please wait AMANN Previous Figure 2 23 Screen during de installation link to Ethernet MOBY API C Library 38 4 J31069 D0137 U001 A5 7618 03 05 Installation 11 De installation of an existing MOBY API C library is complete ji MOBY API with driver TCP IP Installation Complete Previous Figure 2 24 De installation is complete link to Ethernet Close concludes the dialog MOBY API C Library 4 J31069 D0137 U001 A5 7618 39 Installation 03 05 2 3 1 40 Parameterizing ASM 480 The SLG is connected to Ethernet with the ASM 480 interface module Communication between the application on the PC client and the SLG server via the ASM 480 will only function with unique address assignment e The physical address MAC ID Media Access Control Identity is specified by the manufacturer for each ASM 480 e In addition each ASM 480 requires a logical address IP address Internet Prot
150. s function repeats the MDS command transferred or executed last or the command chain transferred or executed last Byte 0 1 2 3 Parameter 03 OD 00 Mode Mode Binary value 00 hex Repeat until this command arrives with mode 1 01 hex Stop repeating A started command will be processed until the end The MDS command to be executed or the command chain to be executed must contain correct parameters or have already been executed once without errors If the MDS command or the command chain is to be used on different types of MDSs 2 kbyte or 32 kbyte the area to be addressed must be adhered to since otherwise an OD hex error might occur MOBY API C Library 4 J31069 D0137 U001 A5 7618 161 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 3 1 2 6 162 Notice When the REPEAT function is triggered after a RESET SLG STATUS SET ANT or END command the function is rejected with an error status When automatic command repetition is activated and an SLG STATUS is called the SLG STATUS is executed asynchronously Automatic command repetition remains active When an additional MDS enters the antenna field while the command is being executed command execution is terminated with error 1D hex This means that with a command chain every telegram from this time on is acknowledged with an error status When only one MDS is still located in the field the command or the command c
151. s is outside the specified value range the remaining battery life cannot be calculated and the function is terminated with an error c If both values are FF hex days the remaining battery life cannot be calculated and FFFF hex is given in the acknowledgment as the battery life MOBY API C Library We 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 1 2 B 4 1 2 1 System Functions RESET Function You can use the RESET command to reset the SLG U92 to a defined state and specify the system behavior of the SLG U92 by setting the parameters appropriately Standard setting e Bunch multitag 1 Byte 0 1 2 3 4 5 6 7 8 9 10 Parameter OA 00 00 standby param 00 dili mtag fcon ftim U Bit 7 6 15141312110 standby Binary value Standby time during which MDS is to assume standby mode after an MDS command is executed This means that the MDS remains awake so that it can process the next command which must arrive during this standby time without delay The value specifies a factor of 7 msec and not the direct time For instance the value 10 corresponds to 10 x 7 msec 70 msec 0 No standby mode The MDS goes to sleep again after each communication with the MDS 1 to 200 7 msec to 1400 msec param Bit pattern Parameter Bit7to6 0 Bit 5 0 Operation without presence 1 Operation with presence see ANW
152. s to be closed and opened e g when the baud rate changes Otherwise only the data which do not affect interface parameters are accepted e g timeout values Table 2 1 SLG ASM or SIM dependent driver parameters ASM or SIM SLG ASM SIM Dependent Driver asm 824 ASM 724 ASM 424 ASM 420 SIM 41 SLG U92 Parameter Protocol 3964R 3964R 3964R 3964R 3964R 3964R slave slave slave slave master master or slave or slave Baud rate 9600 19200 or 38400 baud 2400 4800 2400 4800 19200 9600 19200 or 9600 baud 38400 or 57600 or 38400 baud 115200 baud aa buffer 200 bytes 242 bytes 242 bytes 255 bytes 255 bytes 255 bytes Receive buffer buffer The size of the send buffer and the receive buffer is determined by the telegram header and the command specific data Telegram header length e 4 bytes with ASM 824 ASM 724 and ASM 424 see appendi AS e 3 bytes with SLG U92 ASM 420 and SIM 41 Notice The MOBY user data may not exceed 248 bytes for the data transmission This means that the maximum length of the data to be read from the MDS or to be written to the MDS is 248 bytes see chapter j MOBY API C Library 28 4 J31069 D0137 U001 A5 7618 03 05 Installation 2 2 3 Priority Assignment for the 3964R Driver The Windows operating system may not exceed the times Acknowledgment timeout and Character timeout during communication between the PC and the SLG ASM or SIM Otherwise communication is ter
153. s used to turn the antenna of the read write device SLG on or off number or the Ethernet interface mode unsigned char 01 hex Turn on antenna 02 hex Turn off antenna sync HANDLE Handle to synchronization with the response telegram Initialized Windows event which the application uses to wait for the response telegram mobyErr_t Pointer to a structure in which the status byte and any error code and interface errors are to be stored See chapte Return value gt 0 No error command executed lt 0 Interface error See chapter 3 7 1 Notice The moby_setANT command may only be sent to the SLG when no command is still queued on the SLG An MDS may already be present in the field of the SLG at the time the antenna is turned on When an MDS is located in the field of the SLG when the antenna is turned off it is reported as not present if the presence check is being used MOBY API C Library 4 J31069 D0137 U001 A5 7618 59 MOBY API C Library 03 05 3 3 7 Function moby_repeat mobyErr_t moby_repeat mobyHandle_t handle unsigned char mode HANDLE sync mobyErr_t err This function is used to repeat the command which was executed last handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface mode unsigned char 00 hex Repeat last command until moby_repeat is finished with mode 01 Conclude repetition A started command will be executed until the end
154. sary corrections included in the next edition Your design comments and suggestions are welcome Siemens AG Automation and Drives Special Products Auromotive Industry Projects Training P O Box 4848 D 90327 Nuremberg Subject to change without prior notice Siemens Aktiengesellschaft Order no 4 J31069 D0137 U001 A5 7618 03 05 Table of Contents Table of Contents MOBY API C Library 4 J31069 D0137 U001 A5 7618 1 Table of Contents 03 05 Function moby_s_end Function moby setANT Function moby_repeat Function moby_ status Function moby statusU Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob Function mob DI DO Functions Function mob Header File MOBY_API H 00 0 ec eee eee eee eeee eee teee ee eeeeneeees Header File 3964R H oo eee eee seca eeeeeeee eee eeeeaeeeenees 110 MOBY API C Library 2 4 J31069 D0137 U001 A5 7618 03 05 Table of Contents Description of Communication to the ASM 424 724 824 with 3964R Protocol Telegram Layout of the Commands Acknowledgments to from the ASM MOBY F Special Features in Read Only Mode Only ASM 824 SLA 81 with MDS F1xx Programming the SLG U92 Based on the Operating System or 3964R Driver SLG STATUS Acknowledgment SLG Diagnosis SLG S
155. scription Hex per Channel 00 00 No error 01 Same as OF 01 02 Presence error Command only partially executed With ASM 824 MDS F1xx 2 data memories in field at once 02 02 Presence error Data memory wasn t processed Timeout for command execution MDS on field boundary 03 03 Error in connection to SLG SLA 04 04 MDS RAM error not initialized 05 05 Unknown command 06 06 Field interference on SLG MOBY F SLA 81 INIT error 07 07 Too many sending errors 08 08 CRC send error 09 09 CRC error during acknowledgment receipt only during initialization OA 10 MDS refuses initialization 0B 11 Timeout during initialization 0c 12 MDS memory cannot be written 0D 13 Address error on MDS MDS on boundary of field OE 14 ECC error OF 01 Startup message 10 16 NEXT command not possible or not permitted 12 18 Internal firmware error 13 19 Watchdog 14 20 Firmware error checksum error telegram stack overflow change in program code timeout for channel connections and so on 15 21 Parameterization error 16 22 Connection configuration unsuitable 17 23 Protocol error 18 Only RESET command permitted 19 25 Buffer overflow entire telegram buffer full Previous command s active 1A PROFIBUS or 3964 error bus link was interrupted 1E 30 Telegram structure is wrong 1F Command or commands were terminated with RESET 20 32 Not an error message binary Only occurs when enabled ECC driver is being used It indicat
156. sed 1 to 4 for SLA or SLG 4x on ASM 424 or 0 if SLG U92 SLG xx on ASM 420 or SIM 4x handle mobyHandle_t Pointer to the handle of the serial interface and the channel number response value after successful function The returned handle is used for all other functions as the input parameter to identify the serial interface and the channel number Return value gt 0 No error command executed lt 0 Windows is unable to open the serial interface see chapte 3 7 1 Notice The channel number is automatically added for each function which is related to this interface MOBY API C Library 4 J31069 D0137 U001 A5 7618 49 MOBY API C Library 03 05 3 2 2 3 2 3 50 Function moby_open for the Ethernet Interface mobyErr_tmoby_open char comStr int channel mobyHandle_t handle unsigned short sPort This function opens the specified MOBY device with the aid of the driver The handle parameter is used to return a handle to the opened MOBY device when a command is successfully concluded This handle must be transferred with all subsequent calls which access this device An open MOBY device must be parameterized before with moby_start and initialized however comStr char IP address of the ASM 480 as character string see chapte Example 157 163 170 12 int Channel number under which the SLG is addressed 0 for SLG U92 handle mobyHandle_t Pointer to the handle of the Ethernet interface return v
157. sible MOBY API C Library 4 J31069 D0137 U001 A5 7618 139 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 3 MOBY U whith multitag processing Read write range adjustable in 0 5 m increments from 0 5 m to maximum 3 5m Bunch multitag lt 12 Proximity switch possible SLG synchronization possible You can select which version by making the appropriate setting in the RESET system telegram see appendices B 3 1 2 1 and B4121 The functions are sent to the SLG U92 as telegrams with the 3964R protocol An acknowledgment with or without user data is returned by the SLG U92 for each telegram received In addition messages may arrive non cyclically from the SLG U92 The telegrams are always comprised of a telegram header and depending on the function no user data or up to 251 bytes of user data A telegram can have up to 254 bytes Telegram structure Telegram Header User Data Max of 251 Bytes Byte 0 1 2 3 to max of 253 bytes AB Com Status User data mand hex hex AB Telegram length in bytes without the AB byte Command Function ID Status Status field Status User data Parameters to write data to MDS read data from MDS diagnostic data status data The 3964R driver must be configured as shown below for communication with the SLG U92 e Data bits 8 e Stop bits 1 e Parity Odd e Send buffer 255 e Receive buffer 255 e Baud rate 19
158. ss Length mand 05 02 00 02 01 A5 1st command Read 20 bytes 2nd command Read 31 bytes 3rd command last command Read 165 bytes All types of MDS commands can be chained In addition the chain can be concluded with the END command This command may not be located within a chain e INIT WRITE and READ command chained AB Com mand Status Date Length jos 4s oo 00 00 8000 AB Com mand Status Address Length Data 05 41 00 00 FO 05 31 37 33 39 30 AB Com mand jo oa MOBY API C Library Status Address Length o o e 4 J31069 D0137 U001 A5 7618 1st command Initialize MDS 2nd command Write 5 bytes 3rd command last command Read 31 bytes 195 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 6 Status Byte The structure of the status byte in acknowledgments and messages from the SLG is described below Possible error codes which may occur in the acknowledgments and messages are also listed Status byte Bit 7 16 151413 2 1 0 Status Bit pattern Bit7to6 0 Bit 5 0 ECC is always on Bit4toO0 Status code 00 hex to 1F hex 00 Noerror Function executed correctly Message without errors 01 Presence error MDS out of field while command still active 02 A queued MDS command was terminated by the turn off antenna command 03 04 Error in M
159. ssing list but continues to keep the MDS in the presence list until the MDS leaves zone 1 01 hex Pause in processing with the MDS The MDS doesn t leave the field of the SLG U92 zone 1 yet At least one further communication with the MDS is planned The parameterized standby time becomes inactive The SLG U92 continues to keep the MDS in both the processing list and the presence list e g READ command pause and then WRITE command MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 3 1 2 5 The END command may only be sent to the SLG U92 after a READ WRITE or INIT command No command may be waiting on the SLG U92 The antenna must be on Otherwise an error message is generated This command refers to the last processed MDS If the MDS has already left zone 1 and mode 01 was selected an error message is sent Similarly if another MDS enters zone 1 and mode 01 was selected an error message is also created REPEAT Function This function is used to automatically repeat an MDS command MDS function or a command chain MDS functions as soon as an MDS enters the antenna field e MDS command INIT WRITE READ and MDS STATUS The END command cannot be automatically repeated e Command chain Chain of MDS commands INIT WRITE READ and MDS STATUS and the END command The END command may only be located at the end of the command chain Thi
160. stem error messages OxA0 00 OxA0 02 OxA0 03 OxA0 04 OxA0 05 OxA0 06 OxA0 07 OxA0 08 OxA0 09 OxA0 0A OxA0 0B OxA0 OC OxA0 0D OxAO 0E OxAO OF OxA0 10 OxAO 11 OxAO 12 OxA0 13 OxAO 14 OxAO 15 OxAO 16 OxAO 17 OxA0 18 OxA0 64 OxA0 65 OxA0 66 OxA0 67 OxA0 68 OxA0 69 OxEO 01 OxE0 02 OxE0 03 No error Transferred handle invalid Not enough memory available No room in the sending buffer Buffer overflow Error during operation on a global event OS error Interface already open Interface not open Not used at this time Not used at this time Not used at this time Not used at this time Not used at this time Not used at this time Not used at this time Not used at this time Message parameter invalid Not used at this time Faulty receive job Faulty send job Not used at this time Not used at this time NAK while sending a telegram Character received while sending a telegram not NAK Interface initialization error Problems with thread or with opening closing the COM interface Not used at this time Not used at this time Not used at this time Not used at this time Addressed port not configured Error while accessing the Windows registry No more ports to open MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library e SLG ASM or SIM For possible error numbers see chapter under MOBY error codes Notice When Windows interrupts communication between PC_and the A
161. still exists is rejected with an appropriate error The moby_diagnose command may be sent to the SLG at any time It is executed immediately When an MDS command such as moby_write moby_read or moby_init is queued on the SLG it is retained The diagnostic information is MOBY U specific The data do not become valid until the synchronization handle signals the receipt of the response telegram For content and meaning see appendices B 2 2 2 3 to B 2 2 2 5 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 3 12 Function moby_unexpect mobyErr_t moby_unexpect mobyHandle_t handle moby_UnexpCallback_t cbroutine This function is used to specify how unexpected messages are to be handled If the parameter cbroutine is NULL all unexpected messages are ignored after this routine is called If not NULL this parameter must be the address of a valid callback routine This routine is jumped to when unexpected messages arrive so that the user program can react to this event When the callback routine is triggered the first 3 bytes of the unexpected telegram and the actual telegram length are transferred These transfer values are defined in the MOBY_API H or MOBY_API_T H header file as typdef void CALLBACK moby_UnexpCALLback_t unsigned char ch1 unsigned char ch2 unsigned char ch3 int laenge see chapter 4 1 or chapter 4 3 handle mobyHandle_t Handle of the serial interface and the channel number
162. t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice For RESET parameters see the documentation of your MOBY e SLG U92 See appendices B 3 1 2 1 and e SLG U92 on ASM 480 See appendix B 4 1 2 1 e SLG on ASM 420 See 01 e SIM 41 See 02 e SLA 8x on ASM 824 See appendix A 6 2 e SLA 7x on ASM 724 See appendix A 6 2 e SLG 4x on ASM 424 See appendix A 6 2 With MOBY E and I the moby_start function corresponds to the RESET telegram with or without parameter transfer MOBY API C Library 4 J31069 D0137 U001 A5 7618 53 MOBY API C Library 03 05 3 3 2 3 3 3 54 Function moby_stop mobyErr_tmoby_stop mobyHandle_t handle This function resets communication with an SLG or SLA on an ASM or SIM and the MOBY DLL After its execution no further commands can be sent to the device until another moby_start Still queued commands are terminated and the waiting threads are informed accordingly handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface Return value gt 0 No error command executed lt 0 Interface error See chapter Notice This routine does not send telegrams to the SLG ASM or the SIM Function moby_next mobyErr_tmoby_next mobyHandle_t handle
163. ted as an error The status information is specific to MOBY The data are not valid until the synchronization handle signals the receipt of the response telegram For content and meaning see appendix B 2 2 2 2 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 3 10 Function moby_anw mobyErr_tmoby_anw mobyHandle_t handle moby_AnwCallback_t cbroutine This function is used to report the presence of the MDS in the field of the SLG The presence message is sent asynchronously by the SLG and is called as a callback routine When operation with presence check was set in the RESET telegram the SLG sends a telegram with the number of MDSs in the field after each change in presence in the SLG s field If one MDS leaves the field and another MDS enters the field at the same time two telegrams are sent If several MDSs enter the field simultaneously each MDS creates a presence message The same applies when MDSs leave the field The transfer value and the number of MDSs in the field are defined with typedef void CALLBACK moby_AnwCallback_t unsigned char anwstatus in the header file MOBY_API H or MOBY_API_T H See also chapter 4 1 or chapter handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface cbroutine Moby_AnwCallback_t Callback routine for the presence message from the SLG MDS has arrived or MDS has departed Return value gt 0
164. terface error See chapter MOBY API C Library 72 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 6 Notice The function sequence is dependent on the fields cweek and year a If the value in the two fields is within the value range the remaining battery life is output in the response telegram b If the two fields contain FF hex the remaining battery life cannot be calculated It is specified as FFFF hex days The status data of the MDS are output anyway After the call the buffer contains the status and diagnostic data of the MDS For the format see the MOBY U documentation 06 Function moby_readOTP mobyErr_t moby_readOTP mobyHandle_t handle unsigned char data HANDLE sync mobyErr_t err This function can be used to read the OTP One Time Programmable memory with a block of 16 bytes 128 bits handle mobyHandle_t Handle of the serial interface and the channel number unsigned char Pointer to the buffer in which the data read from the OTP memory are to be stored The buffer must have a length of at least 16 bytes sync HANDLE Handle to synchronization with the response telegram Initialized Windows event which the application uses to wait for the response telegram err mobyErr_t Pointer to a structure in which the status byte of the response telegram and any error code and interface errors are to be stored See 3 7 2 Return value gt 0 No error command executed lt 0 Inter
165. teway on the ASM 480 The TCP IP configuration is set directly on the ASM 480 with the aid of the following e The four arrow keys Up down right left e The two menu keys ESC OK e The LC display The ASM 480 must be supplied with 24 V for the configuration 1 Setting the IP address a Press OK key Indication Menu Trace b Press down arrow key once Indication Menu Parameter c Press OK key Indication Parameter 3964R 1 d Press down arrow key twice Indication Parameter IP_SETUP e Press OK key Indication IP Addr Byte0 xxx f Press OK key Use the up down arrow keys to enter the number and the right left keys to enter the decimal position of the particular part of the address Confirm your entry with the OK key 2 Setting the subnet mask After the IP address is set the 4 bytes of the subnet mask Net Mask are entered as described under f for setting of the IP address 3 Setting the standard gateway address After the subnet mask is set the 4 byte gateway address Gateway is entered as described under f for setting the IP address After all entries have been made return to the main menu with the ESC key Press the ESC key again to exit input mode The changes are stored when you press the OK key in answer to the query Save Parameter and Restart MOBY API C Library 4 J31069 D0137 U001 A5 7618 41 Installation 03 05 Setting the serial interface on the ASM 480 SL
166. thout the AB byte Address Binary value 0 to maximum length of the user data minus 1 Start address on the MDS for the data to be written The address plus data length must be less than the end address 16 FFFO hex Start address of the OTP memory Length Binary value 1 to 248 Length of the user data to be written Start address length must be less than value of the memory length of the MDS in bytes minus 1 16 Length of the OTP memory Data Binary info User data to be written to the MDS The WRITE command may only be used for the SLG U92 and then only when no command is queued on the SLG U92 The antenna must be on Otherwise an error message is generated When more than one MDS is located in zone 1 the command is terminated with an error When no MDS is located in zone 1 the command waits until an MDS enters zone 1 or a RESET command arrives Notice The 128 bits of user information in the OTP memory are addressed with the start address 16 FFFO hex The OTP memory can only be written once The write command must transfer all 128 bits of information at one time A second write attempt is rejected with an error message MOBY API C Library 4 J31069 D0137 U001 A5 7618 143 Programming the SLG U92 Based on the Operating System or 3964R Driver 03 05 B 2 1 1 3 READ Function 144 The READ function is used to read data from the MDS which is located in the antenna field of the SLG U92 It is an untargeted command si
167. tice The 128 bits of user information in the OTP memory are addressed with the start address 16 FFFO hex The OTP memory can only be written once The write call must contain all 128 bits of information A second attempt to write is rejected with an error message MOBY API C Library 174 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 1 1 3 READ Function You can use the READ function to non specifically or specifically read data from an MDS that is located in the antenna field of the SLG U92 e A read call is non specific when the call does not include the identification number of the MDS Only one MDS may be located in the antenna field e A read call is specific when the call includes the identification number of the MDS More than one MDS may be located in the antenna field You can determine the identification number of the MDS with the GET function Byte 0 1 2 3 bis 6 7 8 9 Parameter 09 02 00 MDS no address length MDS no Binary value 0 When an MDS is located in the antenna field and a non specific read call is to be performed Value 2 to 2 1 MDS no of the MDS which is to be read Address Binary value 0 to maximum length of user data minus 1 Start address on the MDS of the data to be read The address plus data length must be less than the end address 16 FFFO hex Start address of the OTP memory Len
168. tion with parameter is used the RESET telegram is always used to set the interval parameters When MOBY Ib is specified the second parameter version use of extra parameters e g LED Settings is used Short RESET telegram MOBY call compatible no multitagging MOBY_Ub SLG U92 Long RESET telegram MOBY call compatible no multitagging MOBY Uc SLG U92 SLG U92 on ASM 480 Long RESET telegram MOBY U commands for single tagging or multitagging operation e Value in param 1 single tagging e Value in param gt 1 multitagging 52 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library handle mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface type mobyTypeee_t Character string with the name of the MOBY system MOBY_E MOBY_F MOBY_ MOBY_la MOBY _ b MOBY_Ua MOBY_Ub MOBY_Uc eccON Boolean value for MDS functions with or without ECC offset FALSE No ECC offset TRUE ECC offset param mobyParameters _t Pointer for parameter transfer NULL No parameter transfer standard RESET or pointer to the buffer in which the parameters to be transferred are located RESET parameters sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram err mobyErr_
169. ttern 00 hex MDS no 1 Binary value Value 2 to 2 4 MDS no of the read MDS source MDS no 2 Binary value Value View 4 MDS no of the written MDS destination Acknowledgment with error status not equal 00 hex Byte 0 1 2 3 to6 7 to 10 Parameter OA 07 status MDS no 1 MDS no 2 Status Bit pattern For status see appendix B 6 MDS no 1 Binary value Value 2 to2 1 MDS no of the not read MDS source 0 MDS no 1 not processed MDS no 2 Binary value Value 2 to2 1 MDS no of the not written MDS destination 0 MDS no 2 not processed B 4 2 1 6 MDS STATUS Acknowledgment See appendix B 4 2 2 Acknowledgments to System Functions B 4 2 2 1 RESET Acknowledgment See appendix B 4 2 2 2 SLG STATUS Acknowledgment SLG Status See appendix MOBY API C Library 199 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 2 2 3 SLG STATUS Acknowledgment SLG Diagnosis l See appendix B 4 2 2 4 SLG STATUS Acknowledgment SLG Diagnosis II See appendix B 4 2 2 5 SLG STATUS Acknowledgment SLG Diagnosis III See appendix B 4 2 2 6 SET ANT Acknowledgment See appendix B 4 2 2 7 END Acknowledgment Acknowledgment without error status 00 hex Byte 0 1 2 3 to6 Parameter 06 08 status MDS no Status Bit pattern 00 hex MDS no Binary value Value 2 to 2 1 MDSno Acknowledgment with error status
170. unction reads digital inputs Dl handle mobyHandle_t Handle of the serial interface and the channel number deda mobyDEDA t Pointer to the structure in which the read signal states are stored sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response telegram mobyErr_t Pointer to the structure in which the status byte of the response telegram with any error codes and interface errors is to be stored see chapter 3 7 2 Return value gt 0 No error command executed lt 0 Interface error See chapter Notice After the call the signal states of the digital inputs are available in the buffer The number and type of representation vary depending on the particular MOBY system See documentation 01 or 02 of your MOBY MOBY API C Library 4 J31069 D0137 U001 A5 7618 91 MOBY API C Library 03 05 3 5 2 92 Function moby_writeDA mobyErr_t moby_writeDA mobyHandle_t handle mobyDEDA_t deda HANDLE sync mobyErr_t err This function sets writes the digital outputs DO handle mobyHandle_t Handle of the serial interface and the channel number deda mobyDEDA_t Pointer to the buffer in which the signal states to be written are stored sync HANDLE Handle for synchronization with the response telegram Initialized Windows event due to which the application is waiting for the response mobyErr_t Pointer to t
171. us 00 ANW S Status Bit pattern For status see appendix ANW S Binary value Presence status Number of MDSs in the field zone 1 0 to 12 When the presence check bit is set in the RESET telegram the SLG U92 sends a telegram with the number of MDSs in the field each time presence changes in the field zone 1 When one MDS leaves the field at the same time as another MDS is entering the field 2 ANW MELD messages are sent If several MDSs enter the field simultaneously each MDS generates an ANW MELD message The same applies when the field is exited The presence message is sent asynchronously by the SLG U92 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver MOBY Call Compatible Version 2 Initialize MDS Write data block B 3 B 3 1 Telegrams to the SLG U92 MDS functions e INIT e WRITE e READ e MDS STATUS System functions e RESET e SLG STATUS e SET ANT e END e REPEAT e L UEB Read data block MDS status diagnosis Reset SLG SLG status diagnosis Turn antenna on off Conclude communication with MDS Repeat last command Line monitoring The RESET command is used to reset the SLG U92 to a defined state You determine the reaction of the SLG U92 by setting the applicable parameters Telegram overview Telegram Header User Data Max of 251 Bytes 0 Telegram Function INIT 1 2 3 to max of
172. v_ver unsigned char inter unsigned char baud unsigned char dili unsigned char mtag unsigned char fcon unsigned char ftim unsigned char sema unsigned char ant unsigned char standby unsigned char anw mobyStatusU t typedef struct mobyStatusMDS_d mobyStatus_t status unsigned long int mds_no unsigned char mds_type unsigned long int strz unsigned short int ssmz unsigned short int mcod unsigned short int rbld unsigned char sleep time mobyStatusMDS t typedef union mobyErr d long error mobyStatus_ t status mobyErr t MOBY API C Library 4 J31069 D0137 U001 A5 7618 103 Header Files 03 05 EESTE E EES VENDEE EE OTENE EINE Nee Sal le St in ee Cal a ee definitions for moby_diagnose for MOBY U only define MOBY U MAXFUNC 33 typedef struct funcDesc_d unsigned char data 7 funcDesc_t typedef struct mobyDiagnoseCall d mobyStatus_t status unsigned int num funcDesc_t functions MOBY _U_MAXFUNC mobyDiagnoseCall t define MOBY U MAXERR 233 typedef unsigned char errDesc_t typedef struct mobyDiagnoseErr_ d mobyStatus_ t status unsigned int num errDesc_t error MOBY_U_MAXERR mobyDiagnoseErr t define MOBY U MAXMDS 24 typedef struct mdsDesc d unsigned char data 4 mdsDesc_t typedef struct mobyDiagnoseMDS d mobyStatus_ t status unsigned int num mdsDesc_t mds MOBY_U_MAXMDS mobyDiagnoseMDS t typedef struct mobyDiagnoseRepeat_d unsigned int num
173. with moby_stop No ID numbers with MOBY Handle still open Command terminated by error implicit moby_stop Channel already open Channel already started Channel not yet started Last status query not yet concluded This number MOBY_ERR_NOTSUPPORTED stands for functions not covered by the selected interface e g moby_s_getID when there is no MOBY U SLG Wrong IP address assigned Error in socket handle Error in TCP IP connection establishment Invalid device ID When one of the error numbers 0x00 00 0x00 01 0x00 02 0x00 05 0x00 07 0x00 12 0x00 13 0x00 14 or 0x00 15 is reported the applicable interface must be closed with moby_close if the interface is open and then reopened with moby_open MOBY API C Library 4 J31069 D0137 U001 A5 7618 95 MOBY API C Library 03 05 96 e 3964R driver Status error messages 0x80 01 0x80 02 0x80 04 0x80 08 0x80 10 0x80 20 0x80 40 0x80 80 0x81 00 0x82 00 0x84 00 0x88 00 0x90 00 0xCO 00 Too many jobs sending queue full Attempt to establish connection failed send Telegram transfer failed send Receiving buffer too small for receipt Block check error while receiving Timeout during connection establishment send Timeout during a telegram receive Timeout during connection disconnection send COM message break COM message parity error COM message framing error COM message Overrun Duplex conflict send Unknown system error Sy
174. y command may only be sent to the SLG U92 when no command is yet queued on the SLG U92 The antenna must be on Otherwise an error message is generated If the two specified MDSs are not located in zone 1 the command is terminated with an error Notice The OTP memory cannot be copied with the moby_s_ copy command MOBY API C Library 84 4 J31069 D0137 U001 A5 7618 03 05 MOBY API C Library 3 4 13 Function moby_s_statusMDS mobyErr_t moby_s_ statusMDS mobyHandle_t handle ulnt idData mobyStatusMDS t statusMDS unsigned char mode unsigned char cweek unsigned char year HANDLE sync mobyErr_t err You can use this function to specifically or non specifically query status and diagnostic data from an MDS which is located in the antenna field of the SLG U92 e A read call is specific when the call includes the identification number of the MDS More than one MDS may be located in the antenna field You can determine the identification number of the MDS with the GET function e A read call is non specific when the call does not include the identification rameter of the MDS Only one MDS may be located in the antenna field Parameter mobyHandle_t Handle of the serial interface and the channel number or the Ethernet interface idData ulnt Value from 20 to 232 1 Identification number of the MDS When only one MDS is located in the field and a non specific status query is to be made statusMDS mobyStatusMDS_t
175. y switch turns the field off When there are two proximity switches and a proximity switch time is parameterized the field is automatically turned off when the 2nd proximity switch does not switch within this proximity switch time When there is no proximity switch a proximity switch time must be parameterized After this time the field is automatically turned off Mode 4 SLG synchronization see MOBY U manual for configuration installation and service Proximity switch time 0 when proximity switch mode 0 Proximity switch time 1 to 255 seconds The RESET command may be used on the SLG U92 at all times It is executed immediately If another command is queued it is terminated After the RESET command is executed the antenna of the SLG U92 is on SLG STATUS Function SLG Status Diagnosis See appendix B 3 1 2 2 MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver B 4 1 2 3 SET ANT Function You can use this function to turn the antenna of the read write device SLG U92 on or off Byte 0 1 2 3 Parameter 03 OA 00 mode ode Binary value 01 hex Turn on antenna 02 hex Turn off antenna The SET ANT command may only be used on the SLG U92 when no command is yet queued on the SLG U92 At the time the antenna is turned on one or more MDSs may already be located in the field of the SLG U92 If one or more M
176. y value 00 hex 01 hex 02 hex 03 hex ftim Binary value 0 1 to 255 158 Reduced sending capacity 0 5 m 85 hex 0 5m 1 0 m 8A hex 1 0m 1 5m 8F hex 1 5m 2 0m 94 hex 2 0m 2 5m 99 hex 2 5m 3 0 m 9E hex 3 0m 3 5 m A3 hex 3 5m Proximity switch mode Mode 1 Without proximity switches or SLG synchronization Mode 2 One or two prox switches The proximity switches are logically OR linked While the 1st and or the 2nd proximity switch is on the field is on Otherwise it is off Mode 3 One of two prox switches The 1st proximity switch turns the field on and the 2nd proximity switch turns the field off If there are two proximity switches and a proximity switch time is parameterized the field is automatically turned off if the 2nd proximity switch does not activate within this proximity switch time If the 2nd proximity switch is not present a proximity switch time must be parameterized The field is automatically turned off after this time expires Mode 4 SLG synchronization see MOBY U manual for configuration installation and service Proximity switch time 0 when proximity switch mode 0 Proximity switch time 1 to 255 seconds MOBY API C Library 4 J31069 D0137 U001 A5 7618 03 05 Programming the SLG U92 Based on the Operating System or 3964R Driver The RESET command may be sent to the SLG U92 at all times It is executed immediately Any other queued command is terminated