USER`S MANUAL Multimeter Auto ranging Pocket

image

Contents

1. CAPACITANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batteries and unplug the line cords 1 Set the function switch to the Q gt position Press the MODE button to indicate nF on the display Touch the test leads to the capacitor to be tested s o N Read the capacitance value on the display FREQUENCY DUTY CYCLE MEASUREMENTS 1 Set the function switch to the V Hz position Press the Hz button to display Hz on the display Touch the test probe tips to the circuit under test Read the frequency on the display Press the Hz button again to display on the display Touch the test probe tips to the circuit under test nN QoQ a FF H Read the duty cycle on the display NON CONTACT AC VOLTAGE MEASUREMENT WARNING Risk of electrocution Before use always test the Voltage Detector on a known live circuit to verify proper operation The Voltage Detector works with the function switch in any position including OFF 1 Bring the probe tip next to the hot conductor or insert into the hot side of the electrical outlet 2 If AC voltage is present the detector light will illuminate NOTE The conductors in electrical cord sets are often twisted For best results rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conducto
2. 2 If OL appears in the display during a measurement the value exceeds the range you have selected Change to a higher range NOTE On some low AC and DC voltage ranges with the test leads not connected to a device the display may show a random changing reading This is normal and is caused by the high input sensitivity The reading will stabilize and give a proper measurement when connected to a circuit AC DC VOLTAGE MEASUREMENTS CAUTION Do not measure AC DC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set the function switch to the V position 2 Press the MODE button to indicate DC or AC on the display 3 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit 4 Read the voltage in the display AC DC CURRENT MEASUREMENTS 1 For current measurements up to 4000A C DC set the function switch to the yA position 2 For current measurements up to 200mA AC DC set the function switch to the mA position 3 Press the MODE button to indicate AC or DC on the display 4 Remove power from the circuit under test then open up the circuit at the point where you wish to measure current 5 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit 6 Apply power to
3. 2 0 rdg 5digits 3 3 4 digit 4000 count LCD display Built in non contact AC voltage detector Flashlight Double Molded housing CATIV 600V 200mA 500V Resettable Fused current inputs and Overload protection on all ranges Autoranging with auto power off Input Limits Function Maximum Input V DC or VAC 600V DC AC LAAC DC 200mA 500V fast acting resettable fuse Resistance Diode amp 600V DC AC Continuity Test 2 USE EXTREME CAUTION when working with voltages greater than 25VAC rms or 35VDC These voltages are considered a shock hazard 3 DO NOT measure voltage if the voltage on the COM input jack exceeds 600V above earth ground 4 ALWAYS discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests 5 NEVER connect the meter leads across a voltage source when the function switch is in the current resistance or diode mode 6 ALWAYS turn off the meter and disconnect the test leads from the circuit before opening the cover to replace battery 7 ONLY operate the meter with the battery cover fastened securely Meter Description 1 Non contact AC voltage detector probe tip 2 Non contact AC voltage indicator light 3 3 3 4 Digit 4000 count 1 m 8 4 MODE button 22 5 Function switch 6 Flashlight i 7 Flashlight button il li 8 Hz Duty Cycle button i 9 Battery Cover gt gt 10 Test leads Note Accuracy specifica
4. USER S MANUAL Multimeter Auto ranging Pocket DMM DMR 602 CIRCUIT TEST ELECTRONICS www circuittest com Features Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present E Double insulation Safety Precautions This meter has been designed for safe use but must be operated with caution The rules listed below must be carefully followed for safe operation 1 Do not exceed the maximum rated input limits Specifications Function Range amp Resolution Accuracy DC Voltage 400mV 4 000V 40 00V 0 8 rdg 2digits 400 0V 600V 1 0 rdg 2digits AC Voltage 4 000V 40 00V 1 0 rdg 5digits 50 60Hz 400 0V 600V 1 5 rdg Sdigits 400 0uA 4000A ee DC Current 40 00mA 200 0mA 2 0 rdg 2digits 400 0uA 40004A E a ae rar Ser 2 5 rdg 5digits 400 00 0 8 rdg 5digits 4 000kQ 1 2 rdg Sdigits Resistance 40 00kQ 400 0kQ 0 8 rdg 2digits 4 000MQ 0 3 rdg 5digits 40 00MQ 5 0 rdg Sdigits 4 000nF 5 0 rdg 0 6nF Geta 40 00nF 3 5 rdg 30digits 400 0nF 4 000uF 3 0 rdg 20digits 40 00uF 200 0uF 5 0 rdg 30digits Frequency ae 999 9Hz 1 0 rdg 2digits Duty Cycle 0 5 99
5. m the warranty Except as stated above Circuit Test Electronics makes no promises or warranties either expressed or implied including warranties of merchantability or the fitness for any particular purpose M DMR 602 07R13
6. r NOTE The detector is designed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor This is normal operation FLASHLIGHT Press and hold the w button to turn the flashlight on Release the button to turn the flashlight off AUTO POWER OFF The auto off feature will turn the meter off after 15 minutes Maintenance REPLACING THE BATTERY WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing the battery door il will appear in the display when the battery drops below the operating voltage and requires replacing Turn off the meter Remove the screw securing the battery cover at the bottom of the meter Replace the batteries observing the correct polarity a FF oO N Replace the cover and secure the screw WARNING To avoid electric shock do not operate your meter until the battery cover is in place and fastened securely RESETTABLE FUSE The resettable fuse 200mA 500V will open if the current limits of the meter are exceeded and the fuse will automatically reset itself when the suspected current is removed from the meter s input LIMITED WARRANTY Circuit Test Electronics warrants to the original purchaser that this product be free of defect in material or workmanship for a period of 2 years from the date of purchase Any product which has been subjected to misuse or accidental damage is excluded fro
7. the circuit and read the current in the display RESISTANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Remove the batteries and unplug the line cords 1 Set the function switch to the Q t gt position 2 Press the MODE button to indicate Q on the display 3 Touch the test probe tips across the circuit or part under test It is best to dis connect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 4 Read the resistance in the display CONTINUITY CHECK WARNING To avoid electric shock never measure continuity on circuits or wires that have voltage on them 1 Set the function switch to the Q t gt position 2 Press the MODE button to indicate on the display 3 Touch the test probe tips to the circuit or wire you wish to check 4 Ifthe resistance is less than approximately 1000 the audible signal will sound If the circuit is open the display will indicate OL DIODE TEST 1 Set the function switch to the Q gt position Press the MODE button to indicate gt t on the display Touch the test probes to the diode under test Forward voltage will typically indicate 0 400 to 0 700V Reverse voltage will indicate OL Shorted devices will indicate near OV and an open device will indicate OL in both polarities g
8. tions consist of two elements reading This is the accuracy of the measurement circuit digits This is the accuracy of the analog to digital converter Accuracy is stated at 65 F to 83 F 18 C to 28 C lt 75 RH Non Contact Voltage 100 to 600VAC 50 60Hz Diode Test Continuity Check Audible signal if the resistance is lt 100Q Display 4000 count 3 3 4 digit LCD Over range indication OL is displayed Test current 1mA open circuit voltage of 1 5V DC typical Polarity Automatic sign for negative polarity Low Battery Indication symbol indicates low battery condition Input Impedance gt 7 5MQ VDC amp VAC AC Response Average responding ACV Bandwidth 50Hz to 60Hz Auto Power Off 15 minutes approximately Fuse mA pA ranges 0 2A 500V fast acting resettable fuse Batteries Two 1 5V AAA Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 14 F to 122 F 10 C to 50 C Weight 0 319 Ib 145g Size 104x55x32 5mm 4 09 x2 1 x1 2 Safety Approvals This meter is UL and CUL approved and conforms to IEC61010 1 for Overvoltage Category CAT IV 600V Operating Instructions WARNING Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care 1 ALWAYS turn the function switch to the OFF position when the meter is not in use This meter automatically shuts OFF after 15 minutes of inactivity

Download Pdf Manuals

image

Related Search

Related Contents

Betriebsanleitung FMD 300  Manual - Folder Trade Kft.  Jonny Octave [12/2004]  Advancer Technologies Muscle Sensor v3  Instituto Politécnico de V iseu - Repositório Científico do Instituto  154 - 3 INT Int. TRAYMATIC  取扱説明書 - Clarion  Mode d`emploi  Antenne Wi-Fi 8 dBi, à suspendre ou à poser  Harbor Freight Tools 1624 User's Manual  