8501022A VPX4812 User`s Manual

image

Contents

1. P2 Wafer A B C D E F G 1 J16 SIO11 P J16 SIO11 N GND J16 SIO10 P J16 SIO10 N GND Unused 2 GND J16 SIO9 P J16 SIO9 N GND J16 SIO8 P J16 SIO8 N GND S J16 SIO7 P J16 SIO7 N GND J16 SIO6 P J16 SIO6 N GND Unused 4 GND J16 SIO5 P J16 SIO5 N GND J16 SIO4 P J16 SIO4 N GND 5 J16 SIO3 P J16 SIO3 N GND J16 SIO2 P J16 SIO2 N GND Unused 6 GND J16 SIO1 P J16 SIO1 N GND J16 SIOO P J16 SIOO N GND 7 J16 DPO1 N J16 DPO1 P GND J16 DPOO N J16 DPOO P GND Unused 8 GND J16 DPO3 N J16 DPO3 P GND J16 DPO2 N J16 DPO2 P GND 9 J16 DP11 N J16 DP11 P GND J16 DP10 N J16 DP10 P GND Unused 10 GND J16 DP13 N J16 DP13 P GND J16 DP12 N J16 DP12 P GND 11 J16 DPO5 N J16 DPOS P GND J16 DPO4 N J16 DPO4 P GND Unused 12 GND J16 DPO7 N J16 DPO7 P GND J16 DPO6 N J16 DPO6 P GND 13 J16 DPO9 N J16 DPO9 P GND J16_DPO8_N J16_DPO8_P GND Unused 14 GND J16_DP15_N J16_DP15_P GND J16_DP14_N J16_DP14_P GND 15 J16_DP17_N J16_DP17_P GND J16_DP16_N J16_DP16_P GND Unused 16 GND J16_DP19_N J16_DP19_P GND J16_DP18_N J16_DP18_P GND J15 Connector A B c D E F il PCIE_XMC_PO_RXP PCIE_XMC_PO_RXN 3 3V PCIE XMC P1 RXP PCIE XMC P1 RXN VPWR 2 GND GND NC GND GND XMC_RSTI 3 PCIE_XMC_P2_RXP PCIE_XMC_P2_RXN 3 3V PCIE XMC P3 RXP PCIE XMC P3 RXN VPWR 4 GND GND JTAG TCK GND GND XMC_RSTO 5 PCIE_XMC_P4_RXP PCIE_XMC_P4_RXN 3 3V PCIE XMC P5 RXP PCIE XMC P5 RXN VPWR 6 GND GND JTAG TMS GND GND 12V 7 PCIE_XMC_P6_RXP PCIE_XMC_P6_RXN 3 3V PCIE_X
2. be used 1 2 default JTAG VREF 3 3V IWE 2 3 JTAG_VREF 2 5V JTAG VREF SELECT 4 5 Unused 5 6 Unused SW5 SW3 Acromag Inc Tel 248 295 0310 16 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Front Panel Layout VPX4812 Front Panel On the front panel of air cooled VPX4812 assemblies there are 5 port status LED s The first four LED s indicate the PCle link status for each of the four Fat Pipe connections to other slots on the VPX backplane The fifth LED on the front panel indicates the PCle link status of an XMC module connected to the VPX4812 The table below describes what the LED On Off patterns indicate about the corresponding port states Port Status LED On Off Patterns by State State LED Pattern Link is down Off Link is up Gen 2 0 speed all Lanes are up On Link is up Gen 2 0 speed reduced Lanes are up Blinking 0 5 seconds On 0 5 seconds Off Link is up Gen 1 0 speed all Lanes are up Blinking 1 5 seconds On 0 5 seconds Off Link is up Gen 1 0 speed reduced Lanes are up Blinking 0 5 seconds On 1 5 seconds Off Acromag Inc Tel 248 295 0310 17 WWW acromag com VPX4812 User s Manual 8 0 Handling Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Modules should be handled in ESD safe work areas in order to prevent damage to sensitive components from electrostatic discharges These areas
3. X24s X8d X12d XMC I O PEX 8624 5 PORT PCIE GEN2 SWITCH XMC GEN2 n EXPANSION SITE Acromag Inc Tel 248 295 0310 10 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 5 0 Board Layout XMC XMC ps PO J16 J15 VPX P1 VPX P2 Port DGood Port B Good JTAG LED LED Header Port X Good Port C Good Port A Good LED LED LED wx 2 a E 3 lt a En z 34 x amp gt Acromag Inc Tel 248 295 0310 11 WWW acromag com VPX4812 User s Manual 6 0 Connectors PO Connector Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module PO Wafer A B c D E F G 1 3 3 V 3 3 V 3 3 V Unused 12 V 12 V 12 V 2 3 3 V 3 3 V 3 3 V Unused 12 V 12 V 12 V 3 5 V 5 V 5 V Unused 5 V 5 V 5 V 4 NVRAM_LOCK PLT_RST GND 12V_AUX GND Unused Unused 5 SMB_DATA SMB_CLK GND 3 3V AUX GND Unused Unused 6 GAO GA1 GND 12V_AUX GND GA2 GA3 7 Unused Unused GND Unused Unused GND Unused 8 GND Unused Unused GND A jA GND Low true signal P1 Connector pales A B c D E F G 1 PCIE VPX PO RXP PCIE VPX PO RXN GND PCIE VPX PO TXP PCIE VPX PO TXN GND nused 2 GND PCIE VPX P1 RXP PCIE VPX P1 RXN GND PCIE VPX P1 TXP PCIE VPX P1 TXN GND 3 PCIE VPX P2 RXP PCIE VPX P2 RXN GND PCIE VPX P2 TXP PCIE VPX
4. x4 VPX Fat Pipe B x4 STATION 0 PORT CONFIG OFF VPX Fat Pipe A x8 VPX Fat Pipe B Disabled Sw3 2 ON VPX Fat Pipe C x8 VPX Fat Pipe D Disabled STATION 1 PORT CONFIG OFF default VPX Fat Pipe C x4 VPX Fat Pipe D x4 SW3 3 ON Force Gen 1 0 Speed Only PCIE LINK SPEED OFF default Allow Gen 1 0 amp Gen 2 0 Speeds SW3 4 ON VPWR 12V XMC VPWR VOLT SELECT OFF default VPWR 5V Acromag Inc Tel 248 295 0310 15 www acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module SW4 1 3 Upstream NT Port Selection itch Positi IM rosin Selected NT Upstream Port ON ON ON VPX Fat Pipe A ON OFF ON VPX Fat Pipe B OFF OFF OFF NT Mode Disabled default Note In addition to the switch configuration there are settings for the PEX8624 that must be programmed to the on board EEPROM device to enable Non Transparent Mode Common Uses the 100MHz reference clock pins on the VPX ON bus generated by the CPU board for PCle timing Pins E8 amp MON F8 on the VPX PO connector SELECT Non Common Uses the 100MHz reference clock generated OFF default on board for PCle timing Note Best system stability may be achieved with the use of a 100MHz common clock connection from the SBC especially at Gen 2 0 link speeds If the system does not provide a common clock then non common clock mode must
5. The VPX4812 has been specifically design for use with 3U VPX backplanes and my not be compatible with some 6U backplanes Plugging the board into an unsupported 6U VPX backplane may cause permanent damage Consult the enclosure documentation to ensure that the VPX4812 s power requirements are compatible with those supplied by the backplane Board Keying The 3U VPX backplane specification requires all backplane slots to have two guide pins one above the JO connector and one below the J2 connector As well as providing correct alignment these pins are keyed to prevent cards from being inserted into incorrect backplane slot s to avoid electrical incompatibility The VPX4812 has receptacles for these guide pins see the Connectors section By default these are not keyed Please contact the factory to discuss keying requirements Installation Notes 1 Keying may dictate the backplane slot s into which the VPX4812 can be inserted 2 Air cooled versions have an ejector handle to ensure that the backplane connectors mate properly with the backplane The captive screws at the top and bottom of the front panel allow the VPX4812 to be tightly secured in position which provides continuity with system chassis ground 3 Conduction cooled and REDI versions have screw driven wedge locks at the top and bottom of the board to provide the necessary mechanical thermal interface Correct adjustment requires a calibrated torque wrench set to bet
6. 3 J16 DPO4 N 4 J16 DP14 N 5 J16 DPO5 P 6 J16 DP15 P 7 J16_DPO5_N 8 J16_DP15_N 9 J16_DP06_P 10 J16_DP16_P 11 J16 DPO6 N 12 J16 DP16 N 13 J16 DPO7 P 14 J16 DP17 P 15 J16 DPO7 N 16 J16 DP17 N 17 J16 DP18 P 18 J16 DP19 P 19 J16 DP18 N 20 J16 DP19 N 21 J16 SIO10 P 22 J16 SIO11 P 23 J16 SIO10 N 24 J16 SIO11 N 25 NC 26 NC 27 NC 28 NC 29 NC 30 NC 31 NC 32 NC 33 NC 34 NC 35 NC 36 NC 37 NC 38 NC 39 NC 40 NC Acromag Inc Tel 248 295 0310 27 www acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Certificate of Volatility Certificate of Volatility Acromag Model VPX4812 XXX L LF TRANS V112 L LF Manufacturer Acromag Inc 30765 Wixom Rd Wixom MI 48393 Volatile Memory Does this product contain Volatile memory i e Memory of whose contents are lost when power is removed Yes m No Type SRAM SDRAM etc Size User Modifiable Function Process to Sanitize Yes No Type SRAM SDRAM etc Size User Modifiable Function Process to Sanitize Yes No Non Volatile Memory Does this product contain Non Volatile memory i e Memory of whose contents is retained when power is removed m Yes No Type EEPROM Flash etc Size User Modifiable Function Process to Sanitize EEP
7. application engineers can also be contacted directly for technical assistance via telephone or FAX through the numbers listed below When needed complete repair services are also available Phone 248 295 0310 Fax 248 624 9234 Email solutions acromag com 23 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Appendix A Accessory Modules TRANS V112 The TRANS V112 is the rear transition module for the VPX4812 and is used in backplanes that bring out the rear I O signals from the VPX4812 If you are using a custom backplane you will not need the RTM The TRANS V112 brings out the P16 rear I O signals from the XMC slot on the VPX4812 The signals are brought out by two high speed Samtec differential pair connectors PN QTH 020 01 F D DP A K Acromag Inc Tel 248 295 0310 24 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Switch Settings 1 2 default Orb ground is connected to digital ground SW1 2 3 Orb ground is isolated from digital ground ORBGND 4 5 Unused 5 6 Unused Connectors RP1 Connector RP1 Wafer A B C D E F G l Unused Unused GND Unused J16 SIO10 N GND Unused 2 GND Unused Unused GND J16 SIO8 P J16 SIO8 N GND 3 Unused Unused G
8. must be designed and maintained to prevent ESD damage ESD Safe Work Area Guidelines Acromag Inc Tel 248 295 0310 Module should be handled at properly designated work areas only Designated ESD safe work areas must be checked periodically to ensure their continued safety from ESD The areas should be monitored for the following a Proper grounding methods b Static dissipation of work surfaces C Static dissipation of floor surfaces d Operation of ion blowers and ion air guns Designated work areas must be kept free of static generating materials such as Styrofoam vinyl plastic fabrics or any other static generating materials Work areas must be kept clean and neat in order to prevent contamination of the work area Modules should be handled by the edges Avoid touching component leads NOTE When not installed in a system modules must be enclosed in shielded bags or boxes There are three types of ESD protective enclosure materials this module was shipped in an approved ESD bag Whenever handling the module the operator must be properly grounded by one of the following a Wearing a wrist strap connected to earth ground b Wearing heel grounders and have both feet on a static dissipative floor surface Stacking of modules should be avoided to prevent physical damage 18 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 9 0 Installation IMPORTANT
9. Acromag 4 THE LEADER IN INDUSTRIAL I O VPX4812 Single Slot 3U VPX Bus XMC Carrier Card with P16 Support VPX Switch Card USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom MI 48393 7037 U S A Tel 248 295 0310 Fax 248 624 9234 Copyright 2014 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8501 022A VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module The information contained in this manual is subject to change without notice Acromag Inc makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Further Acromag Inc assumes no responsibility for any errors that may appear in this manual and makes no commitment to update or keep current the information contained in this manual No part of this manual may be copied or reproduced in any form without the prior written consent of Acromag Inc IMPORTANT SAFETY CONSIDERATIONS It is very important for the user to consider the possible adverse effects of power wiring component sensor or software failures in designing any type of control or monitoring system This is especially important where economic property loss or human life is involved It is important that the user employ satisfactory overall system design It is agreed between the Buyer and Acromag that
10. D Unused 14 Unused Unused Unused Unused J16 DP14 N J16 DP14 P GND 15 Unused Unused Unused Unused J16 DP16 P GND Unused 16 Unused Unused Unused Unused J16 DP18 N J16 DP18 P GND Acromag Inc Tel 248 295 0310 25 www acromag com VPX4812 User s Manual P1 Connector Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Pin Number Description 1 J16 DPOO P 2 J16 DPO10 P 3 J16 DPOO N 4 J16 DPO10 N 5 J16 DPO1 P 6 J16 DPO11 P 7 J16 DPO1 N 8 J16 DPO11 N 9 J16 DPO2 P 10 J16 DPO12 P 11 J16_DPO2_N 12 J16 DPO12 N 13 J16 DPO3 P 14 J16 DPO13 P 15 J16 DPO3 N 16 J16 DPO13 N 17 J16_DPO8_P 18 J16_DPO9_P 19 J16_DPO8_N 20 J16_DPO9_N 21 J16 SIOO P 22 J16 SIO1 P 23 J16 SIOO N 24 J16 SIO1 N 25 J16 SIO2 P 26 J16 SIO3 P 27 J16 SIO2 N 28 J16 SIO3 N 29 J16 SIO4 P 30 J16 SIO5 P 31 J16 SIO4 N 32 J16 SIO5 N 33 J16 SIOG P 34 J16 SIO7 P 35 J16 SIO6 N 36 J16 SIO7 N 37 J16 SIO8 P 38 J16 SIO9 P 39 J16 SIO8 N 40 J16 SIO9 N Acromag Inc Tel 248 295 0310 26 www acromag com VPX4812 User s Manual P2 Connector Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Pin Number Description 1 J16_DP04_P 2 J16_DP14_P
11. HUMIDITY 20 80 RH non condensing SHOCK 30 g peak acceleration 11msec 50 g peak acceleration 11msec duration duration VIBRATION 015 38mm peak to peak 030 76mm peak to peak 20 2000 Hz displacement displacement 2 5 g max acceleration 5 0 g max acceleration w 200 lfm airflow must operate in a fully installed conduction cooled rack must operate in a fully installed conduction cooled REDI rack EMI EMC Regulatory Compliance Caution This module generates uses and can radiate electromagnetic energy It may cause or be susceptible to EMI if not installed and used in a cabinet with adequate EMI protection The VPX4812 is designed using good EMC practices and when used in a suitably EMC compliant chassis should maintain the compliance of the total system The VPX4812 also complies with EN60950 product safety which is essentially the requirement for the Low Voltage Directive 73 23 EEC Air cooled build levels of the VPX4812 are designed for use in systems meeting VDE class B EN and FCC regulations for EMC emissions and susceptibility Conduction cooled and REDI build levels of the VPX4812 are intended for integration into EMC hardened cabinets boxes Acromag Inc Tel 248 295 0310 22 WWW acromag com VPX4812 User s Manual 11 0 Service and Repair Service and Repair Assistance Preliminary Service Procedure Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Surface Mount
12. MC_P7_RXP PCIE_XMC_P7_RXN VPWR 8 GND GND JTAG_TDI GND GND 12V AUX 9 NC NC NC NC NC VPWR 10 GND GND JTAG_TDO GND GND GAO 11 PCIE XMC PO TXP PCIE XMC PO TXN NC PCIE XMC P1 TXP PCIE XMC P1 TXN VPWR 12 GND GND GA1 GND GND NC 13 PCIE_XMC_P2_TXP PCIE_XMC_P2_TXN 3 3V_AUX PCIE_XMC_P3_TXP PCIE_XMC_P3_TXN VPWR 14 GND GND GA2 GND GND SMB_DATA 15 PCIE_XMC_P4_TXP PCIE_XMC_P4_TXN NC PCIE_XMC_P5_TXP PCIE XMC P5 TXN VPWR 16 GND GND NVRAM LOCK GND GND SMB CLK d PCIE XMC P6 TXP PCIE XMC P6 TXN NC PCIE XMC P7 TXP PCIE XMC P7 TXN NC 18 GND GND NC GND GND NC 19 PCIE VPX REF CLK P PCIE VPX REF CLK N NC NC ROOTO NC Low true signal Acromag Inc Tel 248 295 0310 13 www acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module J16 Connector A B c D E F 1 J16 DPOO P J16 DPOO N NC 116 DPO1 P 16 DPO1 N NC 2 GND GND NC GND GND NC 3 116 DPO2 P J16 DPO2 N NC J16 DPO3 P 16 DPO3 N NC 4 GND GND NC GND GND NC 5 116 DPO4 P 116 DPO4 N NC 116 DPOS P 16 DPO5 N NC 6 GND GND NC GND GND NC 7 116 DPO6 P 116 DPO6 N NC J16 DPO7 P 16 DPO7 N NC 8 GND GND 116 SIO10 N GND GND J16_SIO11_N 9 116 DPO8 P 116 DPO8 N 116 SIO10 P J16 DPO9 P 16 DPO9 N 16 SIO11 P 10 GND GND 116 SIO8 N GND GND 116 SIO9 N 11 116 DP10 P J16 DP10 N 116 SIO8 P 116 DP11 P 16 DP11 N 116 SIO9 P 12 GND GND 116 SIO6 N GND GND 116 SIO7 N 13 116 D
13. ND Unused J16 SIO6 N GND Unused 4 GND Unused Unused GND J16 SIO4 P J16 SIO4 N GND 5 Unused Unused GND Unused J16_SIO2_N GND Unused 6 GND Unused Unused GND J16 SIOO P J16_SIOO_N GND 7 Unused Unused GND Unused J16 DPOO P GND Unused 8 GND Unused Unused GND J16 DPO2 N J16 DPO2 P GND 9 J16 SIO11 P J16 SIO11 N GND J16 SIO10 P Unused GND Unused 10 GND J16 SIO9 P J16 SIO9 N GND Unused Unused GND 11 J16 SIO7 P J16 SIO7 N GND J16 SIO6 P Unused GND Unused 12 GND J16 SIO5 P J16 SIO5 N GND Unused Unused GND 13 J16 SIO3 P J16 SIO3 N GND J16 SIO2 P Unused GND Unused 14 GND J16 SIO1 P J16 SIO1 N GND Unused Unused GND 15 J16 DPO1 N J16 DPO1 P GND J16 DPOO N Unused GND Unused 16 GND J16 DPO3 N J16 DPO3 P GND Unused Unused GND RP2 Connector RP2 Wafer A B C D E F G 1 J16 DP11 N J16 DP11 P GND J16 DP10 N Unused Unused Unused 2 GND 16 DP13 N J16 DP13 P GND Unused Unused Unused 3 J16 DPO5 N J16 DPO5 P GND J16 DPO4 N Unused Unused Unused 4 GND 16 DPO7 N J16 DPO7 P GND Unused Unused Unused 5 J16 DPO9 N J16 DPO9 P GND J16 DPO8 N Unused Unused Unused 6 GND 16 DP15 N J16 DP15 P GND Unused Unused Unused 7 J16 DP17 N J16 DP17 P GND J16 DP16 N Unused Unused Unused 8 GND 16 DP19 N J16 DP19 P GND Unused Unused Unused 9 Unused Unused Unused Unused J16 DP10 P GND Unused 10 Unused Unused Unused Unused J16 DP12 N J16 DP12 P GND 11 Unused Unused Unused Unused J16 DPO4 P GND Unused 12 Unused Unused Unused Unused J16 DPO6 N J16 DPO6 P GND 13 Unused Unused Unused Unused J16 DPOB8 P GN
14. P SENSOR Power Up Reset Sequence From the application of 3 3V and 5V power to all components being out of reset typically takes 250ms Since the ramp up times of the 3 3 V and 5 V system power source and the onboard power source will vary with load the time taken for the VPX4812 to come out of reset will vary from system to system It is the software s responsibility to account for this Bus Compliance Vita 46 0 46 4 46 9 48 and 65 MIL Spec 217 F MTBF TBD Form Factor 3U VPXbus 3 94 100mm x 6 3 160mm Flammability The circuit board is made by an UL recognized manufacturer and has a flammability rating of UL94V 1 Acromag Inc Tel 248 295 0310 21 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Environmental Caution The VPX4812 requires air flow of at least 200 linear feet minute for the air cooled version plus what is required for an XMC device installed on this module If the conduction cooled version is operating on an extender card it requires air flow of at least 300 linear feet minute across it Versions using the REDI covers must not be operated outside of a fully configured and fully installed conduction cooled REDI system ENVIRONMENTAL SPECIFICATION OPERATING NON OPERATING THERMAL Air cooled 0 to 70 C 40 to 85 C Conduction cooled 40 to 85 C 40 to 105 C REDI Cover Conduction cooled 40 to 85 C 40 to 105 C
15. P12 P J16 DP12 N 116 SIO6 P 116 DP13 P 16 DP13 N J16 SIO7 P 14 GND GND 116 SIO4 N GND GND 116 SIO5 N 15 116 DP14 P 116 DP14 N 116 SIO4 P 116 DP15 P 16 DP15 N 116 SIOS P 16 GND GND 116 SIO2 N GND GND 116 SIO3 N 17 116 DP16 P J16 DP16 N J16 SIO2 P J16 DP17 P 16 DP17 N J16 SIO3 P 18 GND GND J16_SIOO_N GND GND J16_SIO1_N 19 J16 DP18 P J16 DP18 N 116 SIOO P J16 DP19 P 16 DP19 N J16 SIO1 P J5 Connector JTAG Header Pin Number Description 1 JTAG TDI JTAG TDO GND JTAG TCK JTAG TMS DUBU M JTAG VREF Acromag Inc Tel 248 295 0310 14 www acromag com VPX4812 User s Manual 7 0 Switch Settings Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module The following describes the VPX4812 switches with their default positions and their functions SW1 Upstream Port Selection Switch Position I P 1 2 3 4 Selected Upstream Port ON ON ON ON VPX Fat Pipe A default OFF ON ON ON VPX Fat Pipe B OFF ON OFF ON VPX Fat Pipe C ON OFF OFF ON VPX Fat Pipe D ON ON ON OFF XMC 1 2 default FRU uses 3 3V sw2 2 3 FRU uses 3 3V_AUX PRUSEL A 4 5 defaul Orb di d to digital d ORBGND 5 default rb ground is connected to digital ground 5 6 Orb ground is isolated from digital ground Orb ground is the front panel and the VPX key guides SW3 1 ON default VPX Fat Pipe A
16. P2 TXN GND nused 4 GND PCIE VPX P3 RXP PCIE VPX P3 RXN GND PCIE VPX P3 TXP PCIE VPX P3 TXN GND 5 PCIE VPX P4 RXP PCIE VPX P4 RXN GND PCIE VPX P4 TXP PCIE VPX P4 TXN GND nused 6 GND PCIE VPX P5 RXP PCIE VPX P5 RXN GND PCIE VPX P5 TXP PCIE VPX P5 TXN GND 7 PCIE VPX P6 RXP PCIE VPX P6 RXN GND PCIE VPX P6 TXP PCIE VPX P6 TXN GND nused 8 GND PCIE VPX P7 RXP PCIE VPX P7 RXN GND PCIE VPX P7 TXP PCIE VPX P7 TXN GND 9 PCIE VPX P8 RXP PCIE VPX P8 RXN GND PCIE VPX P8 TXP PCIE VPX P8 TXN GND nused 10 GND PCIE VPX P9 RXP PCIE VPX P9 RXN GND PCIE VPX P9 TXP PCIE VPX P9 TXN GND 11 PCIE VPX P10 RXP PCIE VPX P10 RXN GND PCIE VPX P10 TXP PCIE VPX P10 TXN GND nused 12 GND PCIE_VPX_P11_RXP PCIE_VPX_P11_RXN GND PCIE_VPX_P11_TXP PCIE_VPX_P11_TXN GND 13 PCIE VPX P12 RXP PCIE VPX P12 RXN GND PCIE VPX P12 TXP PCIE VPX P12 TXN GND nused 14 GND PCIE VPX P13 RXP PCIE VPX P13 RXN GND PCIE VPX P13 TXP PCIE VPX P13 TXN GND 15 PCIE VPX P14 RXP PCIE VPX P14 RXN GND PCIE VPX P14 TXP PCIE VPX P14 TXN GND nused 16 GND PCIE VPX P15 RXP PCIE VPX P15 RXN GND PCIE VPX P15 TXP PCIE VPX P15 TXN GND RX is defined as a signal that is an input to the VPX4812 TX is defined as a signal that is an output from the VPX4812 Acromag Inc Tel 248 295 0310 12 www acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module P2 Connector
17. ROM AT25640B 64 KB m Yes Store settings for Device can be accessed via SPI No PEX8624 PCle switch through the PEX8624 Device can be sanitized by writing O s to all bits Type EEPROM Flash etc Size User Modifiable Function Process to Sanitize EEPROM PCA9500BS 2 kbit m Yes Misc storage Device can be accessed via No SMBus on host CPU Device can be sanitized by writing O s to all bits Type EEPROM Flash etc Size User Modifiable Function Process to Sanitize Yes No Other capabilities Does device contain media storage capabilities Yes m No If yes explain Is this device capable of wireless transmission Yes m No If yes explain Acromag Representative Name Joseph Primeau Title Email Office Phone Office Fax Dir of Sales and Marketing solutions acromag com 248 624 1541 248 624 9234 Acromag Inc Tel 248 295 0310 28 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Revision History The following table shows the revision history for this document EGR DOC Description of Revision 4 25 2014 Initial Acromag release Acromag Inc Tel 248 295 0310 29 WWW acromag com
18. al sei skoda EG E E ua 22 EMI EMC Regulatory Compliance cesses enne nennen neter 22 Acromag Inc Tel 248 295 0310 3 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 11 0 Service and Repair erred A de gen aeu egy reve eee AAA 23 Service and Repair Assistance sennae eei ani nnn ns 23 Preliminary Service Proced re ooo aa tte a e ERR UR ENSE rv edv tido 23 Where to Get Help ERE de te O 23 Appendix A Accessory Modules eee eau ee aaa aaa aaa aaa nennen nnn aaa aaa aaa en nes en ness enses s assa saa a saa ansa 24 TRANS VI gt davky ao 24 Certificate of Volatility totu te eee ee A AWA ON ETE EA 28 Revision HIS OVY a a 29 Acromag Inc Tel 248 295 0310 4 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 1 0 General Information The VPX4812 is an XMC Carrier Card Module in the 3U VPX form factor targeted for processing communications and display applications in the commercial military and aerospace markets The VPX4812 provides support for Rear I O connections from the XMC P16 connector The TRANS V112 is the Rear Transition Module for the VPX4812 used to bring out Rear I O connections through the backplane The VPX4812 supports up to four VPX Fat Pipe x4 connections to other cards in the system at Gen 2 0 speeds The VPX4812 can be used as a switch card allowing an upstr
19. eam Fat Pipe or Double Fan Pipe connection typically to a CPU to communicate with up to three downstream Fat Pipe connections or a single Double Fat Pipe connection The VPX4812 also provides support for a VPX Double Fat Pipe x8 connection to an XMC card at Gen 2 0 speeds Key Features e 24 Channel 5 Port PCI Express Gen 2 0 Switch e The XMC site is PCle 8 Lanes Gen 2 0 e Module conforms to VPX Spec VITA 46 0 46 4 and 46 9 e The XMC site supports X24s X8d X12d I O mapping VITA 46 9 e 16 Lanes PCI Express to backplane VITA 46 0 and 46 4 e Supports Non Transparent Bridging Applications e 3U VPX form factor supporting OpenVPX VITA 65 e Air and conduction cooled variants available e REDI covers supporting VITA 48 available Acromag Inc Tel 248 295 0310 5 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Introduction The VPX4812 has two primary functions that can be utilized in a VPX system simultaneously 1 XMC Carrier Card The VPX4812 supports a Double Fat Pipe x8 connection from an XMC module to the on board PCle switch The voltage used to power the XMC module can be toggled between 5V or 12V using a DIP switch located on the VPX4812 2 VPXSwitch Card The VPX4812 contains a 24 lane 5 port PCle switch capable of Gen 2 0 speeds When utilizing the VPX4812 as a switch card a CPU module configured to be an upstream port can communicate with up to th
20. ed Technology SMT boards are generally difficult to repair It is highly recommended that a non functioning board be returned to Acromag for repair The board can be damaged unless special SMT repair and service tools are used Further Acromag has automated test equipment that thoroughly checks the performance of each board Please refer to Acromag s Service Policy Bulletin or contact Acromag for complete details on how to obtain parts and repair Before beginning repair be sure that all of the procedures in section Error Reference source not found Preparation for Use have been followed Also refer to the documentation of your carrier board to verify that it is correctly configured Verify that there are no blown fuses Replacement of the carrier and or IP with one that is known to work correctly is a good technique to isolate a faulty board CAUTION POWER MUST BE TURNED OFF BEFORE REMOVING OR INSERTING BOARDS Where to Get Help Acromag Inc Tel 248 295 0310 If you continue to have problems your next step should be to visit the Acromag worldwide web site at http www acromag com Our web site contains the most up to date product and software information Go to the Support tab to access e Application Notes e Frequently Asked Questions FAQ s Product Knowledge Base e Tutorials e Software Updates Drivers An email question can also be submitted from within the Knowledge Base or directly from the Contact Us tab Acromag s
21. on is opened If the carrier s agent is absent when the carton is opened and the contents of the carton are damaged keep the carton and packing material for the agent s inspection For repairs to a product damaged in shipment refer to the Acromag Service Policy to obtain return instructions It is suggested that salvageable shipping cartons and packing material be saved for future use in the event the product must be shipped This board is physically protected with packing material and electrically protected with an anti static bag during shipment It is recommended that the board be visually inspected for evidence of mishandling prior to applying power The board utilizes static sensitive components and should only be handled at a static safe workstation IMPORTANT Adequate air circulation must be provided to prevent a temperature rise above the maximum operating temperature Adequate air circulation must be provided to prevent a temperature rise above the maximum operating temperature and to prolong the life of the electronics If the installation is in an industrial environment and the board is exposed to environmental air careful consideration should be given to air filtering Acromag Inc Tel 248 295 0310 9 www acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 4 0 Operational Block Diagram VPX PO P1 and P2 CONNECTORS bX d bX old bX 319d bX d FRU EEPROM
22. red at all stages of development The three build levels have three basic mechanical configurations both in accordance with the VITA 46 0 VPX standard and the VITA 48 REDI standard 1 Air convection cooled modules are intended for use in standard industrial chassis 2 Conduction cooled modules are intended for use in sealed Air Transportable Racking ATR and other conduction cooled environments 3 REDI cover Conduction cooled modules are intended for use in sealed Air Transportable Racking ATR and other conduction cooled environments Acromag Inc Tel 248 295 0310 7 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 2 0 Ordering Information VPX4812 Available Models VPX4812 XX Air cooled Model VPX4812 CC XX Conduction cooled Model VPX4812 REDI XX REDI XX Solder L Lead solder LF Lead free solder Acromag Inc Tel 248 295 0310 8 WWW acromag com VPX4812 User s Manual 3 0 Preparation For Use Unpacking and Inspection W CAUTION SENSITIVE ELECTRON DEVICES vo se On STORE REAR ETR WG ELECTROSTATIC ELECTROMAGNETIC MAGNETIC OR AADIDACTIVE FIELDS Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Upon receipt of this product inspect the shipping carton for evidence of mishandling during transit If the shipping carton is badly damaged or water stained request that the carrier s agent be present when the cart
23. ree downstream VPX cards in the system as well as an XMC module on the 4812 The VPX4812 supports the use of non transparent bridging using the on board PCle switch By utilizing non transparent bridging NTB the VPX4812 can be used to implement multi hosted topologies including intelligent adapter cards dual host systems with redundancy and even blade server systems Module and Backplane Profiles The VPX4812 conforms to module profile MOD3 SWH 4F 16 4 5 2 of the VITA 65 specification The VPX4812 conforms to switch slot profile SLT3 SWH 4F 14 4 4 of the VITA 65 specification The VPX 4812 is intended for use in backplane profiles BKP3 CENO6 15 2 12 n of the VITA 65 specification Use of this module in an incompatible backplane profile could result in damage to this module or others in the chassis Slot numbers are logical physical slot numbers may be different Data Plane FP Management Plane IPMB Utility Plane including Power VPX4812 Suggested Backplane Topology Acromag Inc Tel 248 295 0310 6 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Build Levels The VPX4812 is available in three electrically compatible build levels each of which is carefully tailored to a particular set of requirements and environments All three levels fully support the power and versatility of VPX so no matter how large or diversified your project absolute compatibility is assu
24. this is the Buyer s responsibility Acromag Inc Tel 248 295 0310 2 www acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 1 0 er scie mp A ted 5 Key Features 5a ase co dotad RE da 5 InEFOdUCEIO p A ORKA 6 Module and Backplane Profiles esee 6 Build Levels aic A te e e b eee d C Id 7 2 0 Ordering n olt I Lom raka O iaaii PAPA AEC Owa 8 3 0 Preparation For Use te AC ORA AAA OO A Se 9 Unpacking and IRSPECLIO aan n l W OO A A a 9 4 0 Operational Block Diagram EAE aaa aaa aaa a aaa a en ne neni 10 5 0 Board Layout ooi tet trado beendet 1 11 6 0 Solaa eno e m E PT A 12 PU Connectof c O l O A AA 12 ARE olala EA E T E 12 Gees 13 A ee m 13 MA AN 14 J5 Connector JTAG Header 5 sl di 14 7 0 Switch Settihgs cer t ei c eeu n e a rei eet te ee ve e IE 15 Front Panel Lydia na 17 8 0 Handling ta O R DON Rada dd ee t a Aa 18 ESD Safe Work Area GuidelinesS oocccnoocccnnnnoncnnnnnonenancnnnnnnnncnnnnnnnnnnnn nn 18 9 0 Install ii A a A as dl 19 A retenti ee Sees 19 Installation NOTES ios 19 100r i Speciticati OASE o 20 PhYsIEal cette ori a 20 Power Requirements AL 20 Power Consumption siese lav 20 Auxiliary Supplys NA AA 21 Power Up Reset Seguence ooornnoonnon nn ooo tn o ren r rn 21 Bus Compliance otto A tee e E eese t det E s eas 21 EORmiFactOr iii 21 HOM reet dis te re NO ee iS AA 21 Environment
25. ween 0 6 and 0 8 Nm Acromag Inc Tel 248 295 0310 19 WWW acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module 10 0 Specifications Physical Height 100 00 mm 3 937 in Width 160 00 mm 6 299 in Board Thickness 1 575 mm 0 062 in Unit Weight air cooled 5 10 Oz 0 14 Kg Unit Weight conduction cooled 8 34 Oz 0 24 Kg Unit Weight REDI 12 37 Oz 0 35 Kg Power Requirements The VPX4812 requires 3 3V and 5V from the VPX backplane The 12V supplies are used only if required by the XMC module Power Consumption No XMC Card Installed 3 3V lt 1W 5V 2 62W typ 5 43W max 12V OW XMC Card Installed 3 3V lt 1W 5V 80 43W max VPWR 5V 5 43W max VPWR 12V 12V OW max VPWR 5V 60W max VPWR 12V Note The power supplied to the XMC card can be toggled between 5V or 12V depending on the card s requirements and or the power supply s available capacities Caution If VPWR is set to 12V you must ensure that the XMC card is capable of handling a 12V supply voltage If the XMC card is not capable of handling a 12V supply voltage ensure that the VPWR switch is set to supply 5V Acromag Inc Tel 248 295 0310 20 www acromag com VPX4812 User s Manual Single Slot 3U VPX Bus XMC Carrier Card Switch Card Module Auxiliary Supply The following functions may be powered from the 3 3V Auxiliary supply VPX 3 3V_AUX line FRU EEPROM TEM

Download Pdf Manuals

image

Related Search

Related Contents

MANUEL D`UTILISATION DE L`AILE F R A N C A IS  Intermatic T1471BR Instructions / Assembly  10 - Novation  CALL NOW 800-985-6929 http://www.automatedpt.com CALL NOW  Network Camera    descrizione – pulizia – caratteristiche tecniche  GlowShift Instructions  Visualizza il manuale di utilizzo del software  Electrolux EI15TC65HS Wiring diagram  