Home
User manual - Autoplugin
Contents
1. When all three digits entered the module checks the code for validity and confirms it with the direction indicators flashing The both direction indicators flash twice simultaneously in the case of valid code and flash twice alternately in the case of invalid code If entered digit is not correct press and release OK button until the module indicates an error Enter the code once more in that case Several codes can be entered without exit of setup mode Turn the ignition off to exit setup mode New settings are saved in the nonvolatile memory of the module and stored there regardless of whether the module is connected or not Attention If you start the engine without exit Setup mode new settings will not be saved in memory To reset the module to the factory settings enter the code 8 1 1 Both direction indicators in the CIP should flash three times confirming command execution Then the module exits Setup mode and restarts Direction indicators can flash in the Setup mode only for cars with analogue instrument panel For cars with digital instrument panel some cars since MY 2013 use LED s indication of the RCP for settings change Settings Table 3 Settings Settings Possible Values Group Item 1 1 1 Limitation of 1 1 1 Not adjusted Heater s heater s total 1 1 2 40 minutes operation operational time in 1 1 3 50 minutes time pre heat mode 1 1 4 60 minutes 1 1 5 70 minutes 1 1 6 80 minutes 1 1 7 90 minute
2. Wiring for permanent connection Plug n play cable Technical Description brochure Installation Manual brochure A BWN eR Basic Functions 1 A special combination of buttons presses is used to start the heater with the remote control key Firstly press Lamp button on the key to switch on the car s perimeter lighting Then press Lock button twice within 30 seconds while lighting is on Every Lock button s pressing is confirmed with direction indicators flashing 2 To stop the heater with the remote control key switch on and then switch off car s perimeter lighting twice Intervals between Lamp button presses should not exceed 20 seconds 3 It is possible remotely disable startups of the heater programmed in the CIP Use remote control key to send stop command when the heater is idle Starting the heater any way or turning the ignition to on position enables CIP timers again 4 Additionally installed button can be connected to the module The button is used for immediate start and stop of the heater Button pressing changes heater s condition to another one switches off operated heater or switches on idle heater 5 If additional remote control is connected to the RCP the remote control s functions depend on connection schemes module s settings and the remote control s possibilities of See remote control s documentation for details Additional Functions By default RCP is adj
3. stored in the RCP s readjust the module memory incorrectly 11 Heater no The heater is unplugged Make diagnostics of the heater connection or out of order Glossary CAN Control Area Network digital network for data transfer in vehicles RCP Remote Control Plug in electronic module for the heater remote control CIP Combined Instrument Panel Autoplugin ES www autoplugin ru
4. the heater operation Time of signal appearing is defined by the setting 5 1 When the heater operates programmed time the impulse of negative polarity with 1 second duration appears on the output 10 X2 6 Indication The output can be used for connection of outer stand alone or button built in indicator X2 7 Sensor_In Not used X2 8 Sensor_Out Not used X2 9 CAN L Low level CAN bus line has to be connected to the violet orange wire of LOSPEED CAN bus X2 10 CAN H High level CAN bus line has to be connected to the grey orange wire of LOSPEED CAN bus _ See installation manual for connection details Connection RCP Can has a possibility of quick plug n play connection to the OBD II service connector using supplied PnP cable The connection of additional remote control is recommended for professional installation It needs at least some experience in car electronics installation See installation manual for detailed connection schemes for various remotes RCP needs that 2 timers and direct start stop function for the heater control are present in CIP Therefore it may be necessary to load the special software to the CIP at first by the means of Volvo dealer s equipment Troubleshooting If a run time error occurs during the heater s operation RCP informs about the error code with LED flashing The number of flashes corresponds to the error code See table 2 for the error s description and possible solutio
5. 4 7 Error occurred 7 4 8 Disable the output 7 5 Signal feed to the 7 5 1 Heater operates potential output Status Minus 7 5 2 Heater operates autonomously from battery engine is off potential 7 5 3 Heater operates autonomously double impulses with the frequency adjusted by 6 7 applying settings 6 3 6 5 7 5 4 Engine runs potential 7 5 5 Engine runs RPM impulses 7 5 6 Disable the output 7 6 Signal feed to 7 6 1 Heater operates potential the output 7 6 2 Heater operates autonomously from Status Plus battery engine is off potential 7 6 3 Engine runs potential 7 6 4 Ignition is on potential 7 6 5 Disable the output 7 6 6 Feedback for Defa Vehicle Unit 8 8 1 Default Settings 8 1 1 Apply factory settings Service menu Factory setting Recommended settings marked in italics _RCP will turn off the heater if the battery voltage becomes lower than preset T Signals appears only at the heater autonomous operation gt _ Signal is used for indication by all the hazard flashers It uses 1 wire connection to the hazard alarm button see installation manual for details Indication by the turn signals via CAN bus is switched off Signals The module has two connectors 9 pin connector X1 table 1 for input signals and power connection 10 pin connector X2 table 2 for output signals special signals and CAN bus connection The connector s first pin is marked by the key X1 1 H
6. RCP Can V2 Version 7 5 Technical Description User Manual Rev B Table of Contents IDESCHID ION iiss nsen ea S AE a EAE ARA AT sere 2 Module S POSSIDINIUICS ai25 ord encecataannlusis rGlanseiaeda tan tuWanimhaus tte 2 Package Content ernn rae aE ace ah oa Ses ekca al dre acid ein beta ise eto 2 Basie Functions esee vette tetae a atte ape a E a 3 Additional Functions eeneeeesssess sess oreorronssesrsssrsserrrrrersere 3 DIMAS EEEN AE E E S tee animaaeets 7 Connec hons araen a a a a a a aaa 10 TEOUBICS HO OUMG oth sai cena bare Witt ee a E e a A ERE 10 GA Osc i Sere ee MEM e e eee ere eT eT tiene Te Are an a 12 Description The RCP Can V2 is electronic module designed for remote control connection to the fuel fired heater parking heater fuel operated heater pre heater factory installed in Volvo S60 2010 V60 2010 V70 2007 XC70 2007 or XC60 2010 The device controls the heater via CAN bus Module Possibilities Set of inputs for outer heater s remote control using various impulses Set of outputs with programmable heater s status signals Embedded heater s remote control using the car s remote control key Indication of heater s autonomous operation with the direction indicators flashing in the rearview mirrors e Additional protection of the main battery from discharging inspecting voltage level and time of autonomous operation of the heater Package Content RCP Can V2 module 0106 1110
7. eater_off The input can be used to switch off the heater operated in pre heat mode with the impulse of positive polarity the input Heater_off in that case has to be connected to the Ground The heater is stopped by the leading edge of the impulse When the heater is idle positive impulse given to the input cancels the timer start of the heater programmed in the CIP Table 1 X1 pin Signal Name Polarity Wire colour number Heater_off White Heater_off Grey Heater_ont Green Heater_on Blue Button Brown Ventilation Orange RC_in Yellow Ground Black Battery Power Red 1 2 3 4 5 6 7 8 9 The signals to be necessarily connected are marked in the table in Italics Table 2 X2 pin Signal Name Polarity Wire colour Maximum number Electric Load mA Status Plus Blue white Status Minus Yellow Alert 1 Grey Alert 2 Orange Timer out Blue Indication Red white Sensor In Green yellow Sensor Out Green CAN L Brown white VOII NIN Qn BR GQ Nh Re CAN H Brown The connection of outputs 2 5 directly to the Power without a load prohibited The connection of outputs 1 and 6 directly to the Ground without a load prohibited The signals to be necessarily connected are marked in the table in Italics X1 2 Heater_off The input can be used to switch off the heater operated in pre heat mode by the impulse of negative polarity the input Heater_
8. er the heater startup line control time of the heater s autonomous operation 4 1 3 4 1 4 4 1 5 In 15 minutes after the heater startup In 20 minutes after the heater startup In 25 minutes after the heater startup 4 1 6 In30 minutes after the heater startup 4 1 7 In 40 minutes after the heater startup 4 1 8 In 50 minutes after the heater startup 4 1 9 In 60 minutes after the heater startup 4 3 Activate the 4 3 1 Off Timer Out line by the 4 3 2 On second start command 6 Indication with 6 2 Indication of 6 2 1 Off direction command reception 6 2 2 Three flashes indicators in from a remote control 6 the rearview 6 3 Indication ofthe 6 3 1 Off mirrors heater s operation 6 3 2 On when starting source is the remote control 6 4 Indication of the 6 4 1 Off heater s operation 6 4 2 On when starting source is the CIP direct or timer start 6 7 Flashing 6 7 1 One flash within 3 sec frequency for 6 3 6 4 6 7 2 One flash within 5 sec Setup items 6 7 3 One flash within 10 sec 6 7 4 One flash within 15 sec 7 7 3 Notification 7 3 1 Heater started Output signals on the output 7 3 2 Heater stopped signals Alert 1 7 3 5 Heater started to burn adjustment 7 3 7 Error occurred 7 3 8 Disable the output 7 4 Notification 7 4 1 Heater started signals on the output 7 4 2 Heater stopped Alert_2 7 4 5 Heater started to burn 7
9. hannel also may be connected to the input X1 8 Ground X1 9 Power 12V X2 1 Status Plus The assignment of this output is defined by the setting 7 6 By default special signal for Defa Smart Start settings 7 6 3 is used to inform the remote control unit that the heater has been switched off When the heater is switched off the impulse of positive polarity with 0 5 second duration appears on the output When the engine is running the output is permanently pulled up to the Power X2 2 Status_ Minus The assignment of this output is defined by the setting 7 5 By default the signal Heater operates autonomously is given on the output X2 3 Alert_1 The signal is used to receive a notification to remote control if remote is compatible to alerts receiving The assignment of this output is defined by the setting 7 3 When programmed event is occurred the impulse of negative polarity with 1 second duration appears on the output By default the signal Heater started is given on the output X2 4 Alert_2 The signal is used to receive a notification to remote control if remote is compatible to alerts receiving The assignment of this output is defined by the setting 7 4 When programmed event is occurred the impulse of negative polarity with 1 second duration appears on the output By default the signal Heater stopped is given on the output X2 5 Timer_out The output can be used to control an external device by time of
10. ns Table 4 Error Error Possible Reasons of Solutions Code Description Error Appearance 2 No answer Outer temperature is The heater operates only at from the higher than 15 Celsius temperatures below 15 C It heater degrees is the heater manufacturer s followed the restriction start Fuel level in the fuel Refuel the vehicle command tank is close to empty Fuel Low warning indicator is illuminated in the CIP The heater is blocked Try to start the heater in the after 3 unsuccessful CIP menu If it doesn t start starts up make diagnostics of the heater 3 Battery low The module has Charge vehicle s battery with determined that the special charger or start engine battery s voltage is to charge or cancel 3 1 3 2 below the specified by module s settings settings items 3 1 or 3 2 4 Time limits Time limit for Run the engine or cancel 1 1 exceeded autonomous operation of module s settings the heater is achieved with active setting 1 1 5 Unsuccessful The heater was switched Make diagnostics of the heater start off spontaneously at if the error appears again starting 6 Operation The heater was switched Make diagnostics of the heater cycle too off spontaneously if the error appears again short 8 CAN bus There is a problem with Check for the module s error module s connection to connection the CAN bus 9 Settings error Settings have been Reset the settings 8 1 1
11. off in that case has to be connected to the Power The heater is stopped by the leading edge of the impulse If the heater is idle negative impulse on this input cancels the timer start of the heater programmed by CIP This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 3 Heater_on The input can be used to switch the heater on by the impulse of positive polarity the input Heater_on in that case has to be connected to the Ground The heater is started by the leading edge of the impulse X1 4 Heater_on The input can be used to switch the heater on by the impulse of negative polarity the input Heater_on in that case has to be connected to the Power The heater is started by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for connection of outer button The button may be used for the direct start and stop of the heater X1 6 Ventilation The input is not used in current version X1 7 RC_in The input can be used to switch the heater on off by an impulse of positive polarity The heater is turned on by the leading edge of an impulse and is turned off by the trailing edge of the impulse The specialized remotes such as Smart Start Easy Start and Telestart can be connected to this input GSM modules with a potential signal on the control c
12. s 1 1 8 100 minutes 1 1 9 120 minutes 1 2 Limitation of heater s 1 cycle operational time in pre heat mode 1 2 1 10 minutes 1 2 2 15 minutes 1 2 3 20 minutes 1 2 4 25 minutes 1 2 5 30 minutes 1 2 6 40 minutes 1 2 7 50 minutes 1 2 8 60 minutes 1 2 9 70 minutes 2 1 Lock and Lamp buttons functions for the heater control 2 1 1 Lock button for the heater start Lamp button for the heater stop 2 1 2 Lamp button for the heater start Lock button for the heater stop 2 2 Number of 2 2 1 Combination is disabled sequential Lamp 2 2 2 Four presses button presses for the 2 2 3 Six presses heater control 2 2 4 Eight presses 2 3 Number of 2 3 1 Combination is disabled sequential Lock 2 3 2 Two presses button presses for the 2 3 3 Three presses heater control with 2 3 4 Four presses the car s lighting turned on 3 3 1 3 1 1 Not adjusted Battery Minimal battery 3 1 2 11 8V Monitoring voltage that lets the 3 1 3 11 8V module start the 3 1 4 11 9V heater in pre heat 3 1 5 12 0V mode 3 1 6 12 1V 3 1 7 12 2V 3 1 8 12 3V 3 1 9 12 4V 3 2 3 2 1 Not adjusted Minimal battery 3 2 2 11 4V voltage that lets the 3 2 3 11 5V module keep 3 2 4 11 6V operating the heater in 3 2 5 1 7V pre heat mode 3 2 6 11 8V 3 2 7 11 9V 3 2 8 12 0V 4 4 1 Activate the 4 1 1 Don t activate Timer Out Timer Out line by 4 1 2 In 10 minutes aft
13. usted to perform only the basic functions such as start and stop of the heater using the remote control key To turn on the additional functions such as battery monitoring flashing with direction indicators in the rearview mirrors etc enter the module into Setup mode and activate the corresponding setup item see settings table 3 The buttons of the left hand stalk switch and the brakes pedal are used to enter Setup mode and to the settings change It is necessary to stop the engine and the heater before Turn the ignition on press and hold the brakes pedal Rotate the thumbwheel some steps to turn off the display in the CIP Then press and hold for at least 5 seconds OK button while module s LED flashes once a second Both direction indicators in the CIP confirm entering to the setup mode with 2 flashes Release the brakes pedal and OK button finally Each setup item in the settings table is a 3 digit code To enter a digit ofa code shortly press RESET button so much times as corresponds to a digit The LED and the direction indicators symbols in the CIP confirm each button press the LED briefly goes off the left direction indicator flashes one time when the first or the third digit of code is entered the right direction indicator when the second digit of code is entered To complete a digit entering press and release OK 4 button The CIP confirms it with one flash of both direction indicators simultaneously
Download Pdf Manuals
Related Search
Related Contents
UF-130DX - Visono Media Documento - Colombia Manuale di istruzioni CP330PLUS_Hard - Support vaporella forever clean PDF形式 576.3KB Manual - Nevir 取扱説明書 - 三菱電機 MAX S202_IT_v1.2.indd LG 52SX4D-UB User's Manual Copyright © All rights reserved.
Failed to retrieve file