Home

User Manual - TPC Advanced Technology

image

Contents

1. TPC User Manual jiu LED 6 ON Cordless LED Curing Light e LED60N must be installed and operated by a qualified dental professional e All instructions in this USERS MANUAL must be completely read before installation or operation e The user should wear colored protective glasses to avoid eye injury by the LED light REV 1 1 13 Table Of Contents 1 INTRODUCTION 1 1 TECHNICAL INFORMATION 2 FEATURES 3 ACCESSORIES 4 INSTALLATION 5 OPERATION 6 MAINTENANCE 7 WARRANTY 8 IROUBLESHOOTING 3 4 4 5 I INTRODUCTION Thank you for purchasing the LED 60N curing light The LED 60N is a dental curing light which uses the latest LED technology to polymerize composite resin Caution A Attention Important information is being presented Refer to the Operators Manual for more informa tion A High intensitv Light Protect vour eves from the light generated bv this product a Shock Hazard Beware of electrical shock or injury Type B Applied Part IO Class II Medical Equipment X Electronics Waste Properly dispose of when use is discontinued 1 1 Technical Information Range of Light in nm 430 490 nm Light Intensity at the Tip mW cm2 1400 mW Battery Life 200 cycles at STANDARD mode 10 seconds per cycle 135 cycles at STANDARD mode 20 seconds per cycle Charging Time to Complete 5 Hours Battery Type Lithium Ion Cradle Battery Rechargeable Operating Temperature 15 30 C 60 86 F Uni
2. ading from the radiometer is a reference for the user to adjust to appropriate curing time The radiometer is designed to test LED output only 6 MAINTENANCE 1 Be sure there is no resin or material sticking to the surface of the light guide 2 If materials are sticking on the light guide immediately clean it with soft cloth Keep light guide clean for better light intensity and curing performance 3 The light guide should be sterilized after each use It can be safely autoclaved at 121 C For no more then 15 minutes Let cool before handling 4 The other accessories such as curing light hadpiece and eye protector should be scrubbed with pure water and sheathed in accordance with standard disinfection procedures 5 Keep curing light handpiece in charging station while not in use 6 Dispose Lithium battery according to the federal and state laws 7 The User should wear colored protection glasses to avoid eyes injury due to LED light a af _ a _ Warranty Information All of our products sold are guaranteed to be free from defects in workmanship and materials for a 1 year from date of purchase unless otherwise stated TPC will repair or replace any defective part at no charge During the warranty period TPC will not be responsible for labor charges or shipping charges to from the TPC facility This guarantee does not cover normal wear or stains on surface finish The guarantee does not cover damage resulting
3. e battery Return to TPC for service Light guide does not fit properly in O ring is damaged Repalce O ring the end of the curing light Address City CCC tate Zip Phone Number FAX Email Address Model LED 60N Handpiece SN Base SN Please complete this card and return it to TPC Include a copy of your invoice or packing slip Return to TPC Advanced Technology 851 S Lawson St City Of Industry CA 91748 Or Email a scaned copy to service tpcdental com
4. from improper installation or misuse All claims against the freight carrier must be initiated at the time the damaged items are received The claim is the responsibility of the customer We are improving our products on a continuous basis We reserve the right to make modifications without the need for prior notification and are not obligated to modify previously manufactured items Light guides and batteries are not covered under any type of warranty 7 Trouble Shooting Display is not functioning on the J Battery drained curing light Connect to power supply the mode does not change pops back out When i use the light it over heats Send to TPC for service Battery drains very quickly Battery is near end of life The light does not functon after charging but it will function when the power supply is attached to the bottom of the light There is no light emitting from the Damaged LED Send to TPC for service light but the display functions Battery is exhausted When i place the curing light on the charging base the battery does not charge Light not seated in base correctly Dirty Contacts Battery is exhausted Light intensity is reading low light guide is dirty or damaged Battery is low LED is burning out Charge battery Verify charging cycle is complete Replace battery Temporarly use with power supply Replace battery Reseat light in charging base Clean Contacts Repalce battery Clean repalce light guide Charg
5. imultaneously charging the battery 10 Build in LCD Radiometer User can monitor LED output by reading the radiometer which is located on the charging base 3 Accessories 1 Curing Light Handpiece 2 Charging Base 3 Oval Protector 4 Light guide 5 Switching Power Adapter 6 Funchion Switch 7 Curing Switch 4 Installation Step 1 Remove the battery cover located on the side of the handpiece Connect the battery terminals and install the side cover Step 3 Directly insert the Light Guide into the curing light handpiece Verify it has been completely inserted into handpiece Light guide may be rotated to achieve best angle on tooth structure 4 Installation Step 4 Install the eye Protector Step 5 Charge Lithium battery For the best performance Charge curing light handpiece continuously for 4 hours charge battery at least 8 hours prior to inital use The battery symbol on the LCD panel will show the sign of full power when battery is completely charged A flashing battery symbol indicates the battery should be recharged or user can directly connect it to the power supply for uninterupted use LED 60N will detect the charging automatically There will be one short beep tone generated when it has been properly put on to the Charging Base 5 Operation A Set Curing Program Press and hold the function switch for two seconds and you will see the modes change every second To stop on the des
6. ired mode simply let go of the depressed button for the selected mode 1 FAST FI 2 PULSE NN e on LCD Panel 3 RAMP 71 Onn my i DI 1 Curing Time 2 Battery Sign 3 Curing Program B Set Timer Press function switch to select curing time between 5 10 20 30 and 40 seconds e When choosing PULSE or RAMP the curing time will start at 10 seconds automatically JUL A C Start to Operate Press curing switch to begin curing program To interrupt a program just press curing switch again When the curing program is complete the curing light handpiece will beep and then turn off the light immediatelv D Wake Up from Sleeping Mode The curing light will turn into sleeping mode automatically when it is no longer in using for 3 minutes Press function switch or curing switch once to activate curing light E Low Batterv Sign When the is blinking the curing light handpiece should be recharged immediately or directly connected to the power sypply for continued use F Turn off the Power The curing light handpiece will achieve sleeping mode automatically This will shut down all the curing function to save the power User may de activate curing light by disconnecting the battery terminals from the battery G Radiometer Place the light guide against the detective spot on the radiometer The meter will measure the intensity of LED curing light and display the intensity on the LCD display e The output re
7. t turns off automatically when the temperature at the wand tip reaches 48 C Power Input Curing Light 5 VDC 2 4 A Power Input Power Supply 100 240 VAC 50 60 Hz Pulse Rate 10 Hz Pulse Duty Cycle 50 Storage and Transport Conditions 0 40 C 32 104 F 0 100 RH 1000 to 9000 meters elevation 2 FEATURES 1 Latest LED technology 2 Low heat output 3 Easy operating with LCD Display 4 Three preset programs 1 FAST Full power output JUL PULSE 0 5 intermittent output 1 RAMP Soft Start F FAST P PULSE S STEP Light Intensity mW cm Light Intensity mW cm Light Intensity mW em Time sec 2 0 Time sec 0 5 Time sec 0 25 e Follow the manufacturer s instruction to adjust the curing time for better curing performance 5 Timer Five preset curing time from 5 10 20 30 and 40 seconds 6 Low Battery Signal When i is blinking on the LCD Display or a triple beep tone alarmed every 20 seconds the battery needs to be charged for at least 4 hours 7 Sleeping Mode If the LED 60N is unused for a period of 3 minuts the curing light will convert to Sleep Mode to conserve the battery 8 Auto Memory LED 60N will remain in previoussettings including the curing time and the curing program 9 Cord Cordless Interchangeable The LED 60N may be operated directly using AC power supply conncted to the base of the handpiece This will allow users to operate the curing light while s

Download Pdf Manuals

image

Related Search

Related Contents

Fujitsu LIFEBOOK T902  Sanyo MCD-XP630 CD Player User Manual  Les déchetteries et écopoints - Mairie de Sainte Luce sur Loire  Yamaha Electric Accoustic Guitar Owner's Manual  GE EAMD Installation Guide  Philips 191V2SB  Lightolier EG2-8 User's Manual  SMART-24R® (Part A - Main Manual)  Installer manual  