Home
US-BENCHTOP-PRO - User Manual
Contents
1. US BENCHTOP PRO User Manual Capacity 2000g x 0 1g Weighing modes g 0z gn dwt ozt N Thank you for purchasing US BENCHTOP PRO digital scale Please read all operation instructions carefully before use Scales are precision instruments and should always be handled with proper care To ensure years of reliable service keep these simple tips in mind e Do not exceed the scales maximum capacity Overloading your scale can permanently damage it e Avoid exposure to extreme heat or cold Scales perform best at normal room temperature If temperatures have changed dramatically recalibration may be necessary e Allow your scale to acclimate to the room temperature for at least one hour before use e Store your scale in a clean dry location Dust dirt and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction e Avoid using you scale in close proximity to strong radio wave emitting devices such as computers cash registers and cordless phones e Always weigh on a flat level surface free from vibrations and drafts The corner of a room is usually the most stable e Gently apply all items to be weighed Do not drop items onto the weighing platform e Avoid dropping your scale The warranty does not cover damage due to rough treatment or overload l Display Messages e LO Low battery please change the batteries in the scale e Quer The load cell of the scale is being overloa
2. be a quantity of 10 25 or 50pcs previously counted out by hand After the display shows the weight of the items then press the COUNT amp CAL Contar Cal button the display will automatically show 10 use the COUNT amp CAL Contar Cal button to change your quantity selection Until it is the same as the quantity on the scale The PARTS function will be set up automatically once you have chosen the quantity and wait for several seconds Remove the items and the display will show 0 you may now count out items as long as their total weight does not exceed 2000g Once you are finished with the PARTS COUNTING FUNCTION press the COUNT amp CAL Contar Cal again to cancel the PARTS function V OPERATING ENVIRONMENT The optimum operating temperature for the scale is 50 86 F 10 30 C Rough handling of the scale will damage the internal sensor so you must avoid actions such as shaking or dropping the scale This is a sensitive electronic equipment and will be effected by things such as moisture extreme temperature changes magnetic fields careless handling and misuse V AUTOMATIC SHUT OFF The scale will automatically shut off after 60 seconds of inactivity this is to help conserve the battery power We recommend good quality AAA batteries Tested to comply with FCC standards
3. on the platform The scale can be read when the lock sign is shown in the display IIl TARE FUNCTION 1 Turn on scale as described above 2 Place the Tare item on the platform 3 Press Zero button to zero out the display and wait until 0 0 is displayed 4 Place items you want to weigh on the scale Once you finished weighing remove all objects from the scale press the zero again to cancel the TARE FUNCTION III RETURN TO ZERO After weighing an item if the display does not read 0 0 press the TARE button to return to 0 0 and you are ready to weigh again lIl CHANGE WEIGHING MODES Press the MODE button to change weighing modes on your scale This scale has 6 weighing modes g 0z gn dwt ozt N IIl CALIBRATION 1 Place the scale on a flat surface then press Cy key to turn on the scale and wait until 0 0 is displayed 2 Press and hold the COUNT amp CAL button until the display read CAL and then 400 0 will flash on the LCD display 3 Place a total of 400g weight on the center of the platform 4 The LCD display reads PASS and then 400 0 CALIBRATION COMPLETE 5 Remove the weight and press t to turn off the scale Finish Repeat this process if something was going wrong Please check the availability of weights at the store you bought your scale from V PARTS COUNTING FUNCTION Place a small quantity of the item you want to count on the platform please note this should
4. ded You need to remove the excessive weight from the scale immediately e UnSt The scale is placed on an unstable surface please move the scale to a more stable surface e rCAL the scale cannot return to zero please recalibrate the scale CAL This is the prompt for beginning the calibration process of your scale You will see this message when you press and hold the Cal button on your scale Once this message appears you must release the button and follow the remaining steps for calibrating your scale e PASS you have successfully calibrated your scale you are now able to use the scale e FAIL Calibration has failed please make sure you have the scale ona stable surface and that you are using the correct weight lo calibrate the scale Try to calibrate the scale following the calibration instructions exactly l SPECIFICATION 2000g 17 640z 30864gn 1286 5dwt 64 300zt 19 61N 0 1 0 003502 1 54gn 0 064dwt 0 00320zt 0 0009N g oz dwt ozt gn N Tare full capacity 60 seconds 50 86F 2 x AAA Batteries Included 6 4x4 5x1 2 Capacity Readability Tare range Operation temperature US Balance Scale Instructions l ON OFF FUNCTION Place your scale on a flat and stable surface away from any electronic equipment that may interfere with the scale Press and release the O button wait until the A display shows 0 0 and the zero stable signi you may now place the object you A want to weigh
Download Pdf Manuals
Related Search
Related Contents
Ideal Independent C User Manual Manuale installazione cavo Alpha Pegasus-35P™ - Castle Creations Version PDF - Solidaires Finances publiques Boîtier de contrôle GTC ID-Card “LISS/Coombs” Deutsch . . . . . . . . . . . . . . . . . . . . . . Seite 3 KIEN1005S Industrial Ethernet Switch Hardware Installation Manual 取扱説明書 基本ガイド Phonix SA300BCB mobile phone case M1 line c - Ascon S.p.A. Copyright © All rights reserved.
Failed to retrieve file