Home
Users Manual
Contents
1. 416D Laser Distance Meter Users Manual July 2008 O 2008 Fluke Corporation All rights reserved Specifications subject to change without notice All product names are trademarks of their respective companies LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service The warranty period is two years and begins on the date of shipment Parts product repairs and services are warranted for 90 days This warranty extends only to the original buyer or end user customer of a Fluke authorized reseller and does not apply to fuses disposable batteries or to any product which in Fluke s opinion has been misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling Fluke warrants that software will operate sub stantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non defective media Fluke does not warrant that software will be error free or operate without interruption Fluke authorized resellers shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of Fluke Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price Fluke reserves the right to i
2. 1x long a beep is emitted A continuous measurement is started 1x briefly the continuous measurement is stopped The last measured value is displayed in the primary display Minimum Maximum Measuring This function enables determining the minimum or maximum distance from a specific measuring point e g the determination of room diagonals maximum value or horizontal distance minimum value Switching on continuous measurement see above The corresponding maximum and minimum values are displayed Measuring Functions Addition Subtraction Distance Measurement 1x briefly the next measurement is added to HI the previous one 2x briefly the next measurement is subtracted from the previous one Repeat this procedure for as many times as required The result is displayed in the primary display the previously measured value is displayed in secondary display line 2 the value to be added in secondary display line 1 Ea 1x briefly the last step is canceled Area function mw 1X briefly the 4 y symbol is displayed measure 1X briefly takes first distance measurement e g length measure 1X briefly takes second distance measurement e g width The result of the area measurement is displayed in the primary display the individually measured values are displayed in secondary display lines 1 and 2 Adding and subtracting areas Calling up the area function and measuring areas Press on
3. BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE OR THEORY Since some countries or states do not allow limitation of the term of an implied warranty or exclusion or limitation of incidental or consequential damages the limitations and exclusions of this warranty may not apply to every buyer If any provision of this Warranty is held invalid or unenforceable by a court or other decision maker of competent jurisdiction such holding will not affect the validity or enforceability of any other provision Fluke Corporation Fluke Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands 11 99 To register your product online visit http register fluke com Users Manual A The safety instructions and the users manual should be read through carefully before you use the product for the first time The person responsible for the product should ensure that all users understand these directions and follow them Symbols used in this manual The symbols used have the following meaning WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not a
4. is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equipment WARNING The Fluke 416D conforms to the most stringent requirements of the relevant standards and regula tions The possibility of the product causing interference in other equipment cannot be fully excluded Fluke 416D ME Appendix FCC statement applic in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit
5. Cause Correction Error Hardware error Should this message remain active after switching the instru ment off and on several times please contact the dealership Appendix 2 Fluke 416D Technical Specifications Range 0 05 m to 60 m 0 2 ft to 200 ft Measuring accuracy 2 0 typically 1 5 mm 0 06 in Smallest unit displayed 1 mm 1 16 in Laser class 2 Laser type 635 nm lt 1 mW Protection against splashes and dust IP 54 dust proof splash proof Autom power off Laser after 60 s Instrument after 180 s Illumination v Fold out endpiece v Battery life up to Type 2 x AAA 5 000 measurements Dimension 111 x 43 x 23 mm 5 32 x 1 81 x 1 22 in Weight 110 g 3 88 ounces Temperature range Storage 25 C to 70 C 13 F to 158 F Operation 0 C to 40 C 32 F to 104 F Relative humidity 35 C max 85 Altitude 0 to 3500 m Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties in favorable conditions good target surface properties room temperature up to 10 m 33 ft In unfavorable condi tions such as intense sunshine poorly reflecting target surface or high temperature variations the deviation over distances above 10 m 33 ft can change by 0 25 mm m 0 003 in ft Electromagnetic Compatibility EMC The term electromagnetic compatibility
6. different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help WARNING Changes or modifications not expressly approved by Fluke for compliance could void the user s authority to operate the equipment Laser classification The Fluke 416D produces a visible laser beam which emerges from the front of the instrument See drawing K The product is a Class 2 Laser Product in accordance with e 1EC60825 1 2007 Radiation safety of laser products Class 2 Laser Products Do not stare into the beam or direct it unnecessarily at other persons Eye protection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the laser beam with optical aids e g binoculars telescopes can be hazardous Precautions Do not look directly into the beam with optical aids CAUTION Looking into the laser beam may be hazardous to the eyes Precautions Do not stare into beam Do not look into the laser beam Make sure the laser is aimed above or below eye level particularly with fixed installations in machines etc Appendix Elen Fluke 416D Laser Radiation Do not stare into the beam Laser class 2 acc IEC 60825 1 2007 Maximum radiant power lt 1mW Emitted wavelength 620 690nm Beam divergence 0 16 x 0 6 mrad Impulse duration 1x10s Care Wipe off dirt with a damp soft cloth Do not immerse the instrumen
7. for measurements that must be at right angles to the target the maximum distance is used for all other measurements Note Make sure that the first measurement and the distance to be measured are at right angles Use the minimum maximum function Indirect measurement determining a distance using 2 auxilliary measurements See drawing G 1x briefly the N symbol is displayed The distance to be measured flashes in the symbol 1x briefly takes a measurement of the distance The second distance to be measured flashes in the symbol 14 briefly takes a measurement of the hori zontal distance The result of the function is displayed in the primary display If the button is pressed for a long time while measuring a distance maximum or minimum contin UOUS measuring is activated Indirect measurement determining a distance using 3 auxilliary measurements See drawing H fea 2X briefly the gt symbol is displayed The distance to be measured flashes in the symbol measure 1X briefly takes a distance measurement The second distance to be measured flashes in the symbol measure 1X briefly takes a horizontal measurement The third distance to be measured flashes in the symbol measure 1X Driefly takes a measurement of the distance The result of the function is displayed in the primary display If the button is pressed for a long time while measuring a distance maximum or minimum contin uous mea
8. ation units 1x briefly the display illumination is switched on p or off Reference Point Default reference point is from the rear of the instru ment The instrument can be set for the following measure ments e To measure from an edge see drawing DJ fold out the stop bracket until it snaps in for the first time See drawing E e To measure out of a corner see drawing DJ fold out the stop bracket until it snaps in push Fluke 416D the stop bracket with a little force to the right side the stop bracket can now be completely unfolded See drawing E CAUTION Make sure that when measuring from the unfolded endpiece the measuring reference point is set to End piece 1x briefly the next measurement is taken from the front edge 2x briefly the measurement is taken from the unfolded end piece After one measurement the reference point returns automatically to the default setting rear reference point 1x long the measurements are taken with the front as reference until a new measuring refer ence point is set 3 2x long the measurements are taken from the unfolded end piece until a new measuring refer ence point is set See drawing F Fluke 416D Single Distance Measurement 1x briefly the laser is activated 1x briefly a distance measurement is taken The result is displayed immediately Continuous measurement Distances can be measured with this function
9. autions Carry out periodic test measurements Particularly after the instrument has been subject to Start up abnormal use and before during and after important measurements Make sure the Fluke 416D optic is kept clean and that there is no mechanical damage to the bumpers CAUTION In using the instrument for distance measure ments or for positioning moving objects e g cranes building equipment platforms etc unforeseen events may cause erroneous measurements Precautions Only use this product as a measuring sensor not as a control device Your system must be configured and operated in such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur Switching on off 1x briefly the instrument and the laser are switched on The display shows the battery symbol il until the next button is pressed Pressing this button for longer switches the OFF instrument off The instrument switches off automatically after three minutes of inactivity Operation Setting the instrument units Press long until the desired unit is displayed pa Possible units Distance Area Volume 0 000 m 0 000 m 2 0 0 1 16 0 00 ft 0 0 ft 3 0 in 1 16 0 00 ft 0 0 ft 4 0 00 ft 0 00 ft 0 0 ft CLEAR Clear 1x briefly the last action is cancelled OFF Illumin
10. ce twice 1x briefly takes first distance measurement e g length Pa 1x briefly takes second distance measurement e g width The result of the second area measurement flashes 1x briefly confirms the addition the added area results are displayed in the primary display Volume function 2x briefly the g symbol is displayed 1x briefly takes first distance measurement e g length Demu 14 briefly takes second distance measurement e g width The result of the area measurement from the values already measured is displayed in the primary display 1x briefly takes the third distance measure ment e g height The value is displayed in secondary display line 1 The result of the area measurement is displayed in the primary display the two previously measured Functions Sa Fluke 416D values in secondary display lines 1 and 2 Indirect Measurement The instrument can measure distances with the Pythagorean method This procedure facilitates in measuring distances that are difficult to access Note Adhere to the prescribed sequence of meas urements e All target points must be vertical or horizontal on the surface of the wall e The best results are achieved when the instru ment is rotated around a fixed point e g the stop bracket is fully extended and the instrument is placed against a wall e To take the measurement the minimum maximum function can be called up The minimum value is used
11. ig inal equipment Fluke Corporation P O Box 9090 Everett WA Fluke Fluke is responsible for supplying the product including the Users Manual and original accessories ina completely safe condition Responsibilities of the manufacturer of non Fluke accessories The manufacturers of non Fluke accessories for the Fluke 416D are responsible for developing imple menting and communicating safety concepts for their products They are also responsible for the effective ness of these safety concepts in combination with the Fluke equipment Responsibilities of the person in charge of the instrument A WARNING The person responsible for the instrument must ensure that the equipment is used in accord ance with the instructions This person is also accountable for the deployment of personnel and for their training and for the safety of the equipment when in use The person in charge of the product has the following duties e To understand the safety instructions on the product and the instructions in the users manual e To be familiar with local safety regulations relating to accident prevention Overview e To inform Fluke immediately if the equipment becomes unsafe Keypad See drawing A MEASURE Min Max button PLUS MINUS button HEIGHT button UNITS ILLUMINATION button REFERENCE button CLEAR OFF button MEMORY button VOLUME button AREA button OOMONAOUHRKRWNE Fluke 416D D
12. isplay See drawing B Laser ON Reference point front rear end piece Indirect measurement Memory Area volume Battery status Units with exponents 2 3 Secondary display line 2 Secondary display line 1 10 Primary display 11 Min max display 12 Info symbol Start up Inserting Replacing Batteries 1 Remove battery compartment lid See drawing C 2 Insert batteries observing correct polarity 3 Close the battery compartment e Replace the batteries when the symbol il flashes permanently in the display Note Only use alkaline batteries OOMONAOURKRWNE Note If the instrument will not be used for a long time remove the batteries as a protection against corrosion Fluke 416D Measuring Conditions Range Range is limited to 60 m 200 ft At night or dusk and if the target is in shadow the measuring range without the target plate is increased Use a target plate to increase the meas urement range during daylight or if the target has poor reflection properties Target Surfaces CAUTION Measuring errors can occur when measuring toward colorless liquids e g water or dust free glass Styrofoam or similar semi permeable surfaces Aiming at high gloss surfaces may deflect the laser beam and lead to measurement errors Hazards of Use A CAUTION Watch out for erroneous distance measure ments if the instrument is defective or if it has been dropped or has been misused or modified Prec
13. nvoice Buyer for importation costs of repair replacement parts when product purchased in one country is submitted for repair in another country Fluke s warranty obligation is limited at Fluke s option to refund of the purchase price free of charge repair or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period To obtain warranty service contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect mis use contamination alteration accident or abnormal condition of operation or handling including overvoltage failures caused by use outside the product s specified rating or normal wear and tear of mechanical components Fluke will provide an estimate of repair costs and obtain authorization before com mencing the work Following repair the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges FOB Shipping Point THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING
14. suring is activated Fluke 416D SSS Functions Memory 1x briefly the 42 symbol and the last measured value are displayed Use the or LI buttons to navigate through the last 10 values The values can also be used in func tions Using stored values in functions Using added distances in area functions e g wall surfaces Adding distances see additions subtractions FI up area function to e g measure the height of a room memory 1x briefly calls up memory and to search for the correct value memory 1x long the value is entered into the function 4 and the result of the function e g area is displayed Switching off the beep Press and hold simultaneously for 5 seconds The beep is switched off To reactivate it press and hold for 5 seconds Display Notices All display notices are either displayed with or Error The following errors can be corrected Cause Correction 204 Calculation error Repeat procedure 252 Temperature too Let device cool down high 253 Temperature too Warm device up low 255 Received signal too Use a target plate weak time for a measurement too long 256 Received signal too Use target plate gray strong side 257 Faulty measure Use target plate brown ment too much side background light 258 Outside of the Select measurement measurement range distance within the range of measurement Error
15. t in water Do not use harsh cleaning agents or solutions Disposal Do not dispose of this product as unsorted municipal waste Go to Fluke s website for m recycling information All rights reserved for changes drawings descrip tions and technical specifications Fluke 416D Sa Appendix 1 Measure Min Max Area ye Height Volume iL 7 Units a Fig Clear OFF ik iA li II 7 6 l p gt A 4 AA alala juta E 3 12 20 u LA ftim i Co LEE j9 Mafufu pa pay g WIE tim 10 ACAUTIONA LASER RADIATION DO NOT STARE INTO BEAM CLASS II 2 LASER PRODUCT OUTPUT lt 1mW WAVELENGTH 630 670 nm COMPLIES WITH FDA 21CFR 1040 10 11 AND EN60825 1 07 md 2 AAA S NEDA 24A IEC LRO3 FLUKE CORP N0140 EVERETT WA St www fluke com
16. voided may result in minor injury and or in appreciable material finan cial and environmental damage Note Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Intended Use Permitted uses e Measuring distances e Computing functions e g areas and volumes Fluke 416D Adverse uses e Using the instrument without instructions e Using outside the stated limits e Deactivation of safety systems and removal of explanatory and hazard labels e Opening of the equipment by using tools screw drivers etc e Carrying out modification or conversion of the product e Use of accessories from other manufacturers without the express approval of Fluke e Deliberate or irresponsible behaviour on scaf folding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected e Aiming directly into the sun e Deliberate dazzling of third parties even in the dark e Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Limits of use Note Also see section Technical data The Fluke 416D is designed for use in areas perma nently habitable by humans do not use the product in explosion hazardous areas or in harsh environ ments Symbols used in this manual Responsibilities Responsibilities of the manufacturer of the or
Download Pdf Manuals
Related Search
Related Contents
TR138取扱説明書を見る Manual de instalação Manual de instruções VEGAPULS 67 PVRS User Manual V2 H26年度緑の募金事業報告集【pdf:11MB】 Implement a simulator, in Java, for evaluating AntNet routing protocol FP 1000 - Bartscher GmbH Copyright © All rights reserved.
Failed to retrieve file