Home
BF-630 Series User`s Manual
Contents
1. Misc 4 1 Add User 2 Delet User 3 Active User 4 Deactive User 5 Present card Or input id REE Press user ID No EX 666666 5 1 Reg already Modify user YES NO 6 Reg finger YES NO Go to 6 Go to 4 7 Present finger Scanning Place finger on the sensor Processing wait FP 73 9 1 Processing Reg Failed Reg Failed Back 4 10 Reg other finger YES NO If no use go tol4 11 Present finger Scanning Place anther finger on the sensor 12 Processing 13 FP 85 13 1 Processing Reg Failed 14 Reg password YES NO Reg Failed Back 4 16 Write Mifare YES NO 17 Write Mifare YES NO Reg Success Setting Success IBF 630 User Manual www chiyu t com tw 4 1 1 2 Password verify user LCD status Key Setting Description 1 FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 2 Present Manager 111111 Enter 6 digit password default value is 111111 3 1 User 1 2 Setting 3 Reset 4 Misc 4 1 Add User 1 2 Delet User 3 Active User 4 Deactive User 5 Present card etch HE Press user ID No Or input id 5 1 Reg already Go to 6 Modify user Go to 4 YES NO 6 Reg finger 7 YES NO 7 Reg password YES NO 8 User password TERE fE Press user password no Enter 6 digit password 9
2. O Electronic Lock Control Lock open when lock is power off X EXIT BUTTON A VIN VIN 485 485 INO IN1 GND ODO 0D1 NO COM NC rm POWER POWER LOCK DC 12V Lock open when lock is power on X EXIT BUTTON 2 A BER VIN VIN 485 485 INO IN1 GND ODO OD1 NO COM NC F POWER LOCK DC 12V POWER 33 www chiyu t com tw IBF 630 User Manual O Fire Alarm amp Exit Bu Exit Button VIN VIN 485 485 INO 34
3. 01 5 55 4 ssi Sv k r a k aaa l dlde d ul Keda na a a akun 19 4 3 oz yeee 20 4 3 1 Reset User Delete all USET S irpini si it eses ese E aS sau daunn 20 4 3 2 Reset Logs Delete all lo ui 21 4 3 3 IP Config Reset IPren a 21 4 3 4 Reset Group Del Gro Peerna e E cn Bde ek a R ions asi 22 4 4 Misco dida id 22 4 4 1 User Lori a E 22 4 4 2 BEF20 485 Read inicio pto Ais Rae Avian aie as vi 23 4 4 3 Set TM Caducada 24 User s Men tecno ii 25 5 1 For fingerprint verify USET sarsii nen e l sade keka iaeei i ratia ca b e dr eke s i ei 25 5 2 For password verify user 1 1 Verify kereke kek eyek k k ke kk kk r 26 IBF 630 User Manual www chiyu t com tw 5 3 For card verify user 1 N VerifY ocooncnocncconnnoncnncnnnononononacnnonnonacnn corona Va VE a a s Ve RN KO VER Va eke dada bla 27 5 4 For fingerprint password Verify USOT Eu eee keke keke keke kek keke kk kk k ke KE KARAR 28 5 5 Fingerprint or Password verify US r a aaaasaaaainiasasaasasasansasasanansananansananansasnnsasanansnsanaasanananana 29 6 Spectheationss ueno peta sa 29 6 1 Module Features iii 29 6 2 POWer SUppl s roec neseni pabo EEEO Ep EEEE E EE Otak Vas Baa va bp Ka ba aa HHR 29 6 2 1 MONA fer a a r 29 6 2 2 A O UN 29 6 3 Environment A A A 29 6 3 1 Temperature and Humidity v lkk kul a na kan Aa zl dadad Sa Wa n Wala danin 29 6 3 2 Immunity to ele
4. Del GP TZ HD Are You Sure YES NO 6 Del GP TZ HD Are You Sure YES NO Del Success 4 4 Misc 4 4 1 User amp Log LCD status 1 FRI Jan 25 08 10 10 GMT 00 2 Present Manager 3 1 User 2 Setting 3 Reset 4 Misc Key Setting Fl Fl Enter password 111111 4 Description Operation window Enter 6 digit password default value is 111111 4 1 User amp Log 2 BF20 485 Reade 3 Set TM Card 5 User 00000 LOG 00000 22 IBF 630 User Manual www chiyu t com tw 4 4 2 BF20 485 Reade LCD status Key Setting Description 1 FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 2 Present Manager Enter password Enter 6 digit password default 111111 value is 111111 3 1 User 4 2 Setting 3 Reset 4 Misc 4 1 User amp Log 2 2 BF20 485 Reade 3 Set TM Card 5 Entyr XXXXXXXX U represent connect normal Exit XXXXXXXX X represent no connect BF20 xxxxxXxxxX 23 IBF 630 User Manual www chiyu t com tw 4 4 3 Set TM Card 4 4 3 1 Init TM Card LCD status FRI Jan 25 08 10 10 GMT 00 Key Setting Fl Fl Description Operation window Present Manager Enter password 111111 Enter 6 digit password default value is 111111 User Setting Reset 4 User amp Log BF20 485 Reade Set TM Card 1 Init TM Card 2 Write
5. FRI Jan 25 08 09 OOsoo _ 1 1 Verify 1 N Verify 1 1 Verify Place card directly Press E Enter User ID FRI Jan 25 08 Registered ID 09 P 00 GMT 00 kkk Kk kK LegalCad___y Illegal Card Success rar Unregistered w FRI Jan 25 08 09 00200 User password i FRI Jan 25 08 ing GMT jey 09 0 User Denied Success Fail Name Erit User password ekok KKK ID 1164752000 Password Error User Denied 08 30 User Denied Operation description Method A Method B Method C 1 1 verify gt 1 N verify gt 1 1 verify gt max 5000 users less than 100 users max 5000 users 1 Place sensor card on the coil 1 Press Enter User ID No directly 2 Place finger for verify Place finger for verify 2 Place finger for verify 3 Enter User password Enter User password 3 Enter User password 6 10 digit 6 10 digit 6 10 digit Note 1 If you use function key please press function Key first 2 If you want to show name on LCD then you must register Name to BF 660X BF 670X by software 28 IBF 630 User Manual www chiyu t com tw 5 5 Fingerprint or Password verify user Operation is same as 5 1 5 2 and the priority is Password gt Fingerprint for sensor card 1 1 verify Enter ID F will run fingerprint verify 6 Specifications 6 1 Module Features gt Main board gt Key amp LCD board
6. FRI Jan 25 08 10 10 GMT 00 Key Setting Fl Fl Description Operation window 2 Present Manager Enter password 111111 Enter 6 digit password default value is 111111 User Setting Reset 3 Reset User Reset Logs IP Config 1 2 3 4 Misc 1 2 3 4 Reset Group 5 Del All Log Are You Sure YES NO 6 Del All Log Are You Sure YES NO Deleting 7 Del All Log Are You Sure YES NO Del Success 4 3 3 IP Config Reset IP LCD status Key Setting Description 1 FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window 2 Present Manager Enter password 111111 Enter 6 digit password default value is 111111 User Setting Reset 3 Reset User Reset Logs IP Config 1 2 3 4 Misc 1 2 3 4 Reset Group 5 Reset IP Config Are You Sure YES NO 6 Please Wait 7 FW version 0 01 00 Nov 22 2007 21 IBF 630 User Manual www chiyu t com tw 4 3 4 Reset Group Del Group LCD status 1 FRI Jan 25 08 10 10 GMT 00 Key Setting Fl Fl Description Operation window 2 Present Manager Enter password 111111 Enter 6 digit password default value is 111111 User Setting Reset 3 Reset User Reset Logs IP Config 1 2 3 4 Misc 1 2 3 4 Reset Group 5
7. LCD status Key Setting Description FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window Present Manager Enter password 111111 Enter 6 digit password default value is 111111 1 User 2 Setting 3 Reset 4 Misc 2 Note 1 Data amp Time 2 Security Level 3 Administrator 4 IP Config 1P 192168000072 SM 255255235000 GW 192168000001 IP The format of IP subnet mask and gateway are as follow If you want to set IP as 192 168 0 12 then enter 192168000012 If you want to set subnet mask as 255 255 255 0 then enter 255255255000 If you want to set gateway as 192 168 0 1 then enter 192168000001 Enter IP gt Subnet mask Gateway 19 IBF 630 User Manual www chiyu t com tw 4 3 Reset 4 3 1 Reset User Delete all users LCD status Key Setting Description 1 FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 2 Present Manager Enter password 111111 Enter 6 digit password default value is 111111 3 1 User 2 Setting 3 Reset 4 Misc 3 4 1 Reset User 2 Reset Logs 3 IP Config 4 Reset Group 5 Del All User Are You Sure YES NO 6 Del All User Are You Sure YES NO Deleting 7 Del All User Are You Sure YES NO Del Success 20 IBF 630 User Manual www chiyu t com tw 4 3 2 Reset Logs Delete all logs LCD status 1
8. TM Card 1 2 3 4 Misc 1 2 3 Present Card Push Init Card Init Success Init Other Card YES NO 4 4 3 2 Write TM Card LCD status Key Setting Description FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window Present Manager Enter password 111111 Enter 6 digit password default value is 111111 User Setting Reset 3 User amp Log BF20 485 Reade Set TM Card 1 Init TM Card 2 Write TM Card 1 2 3 4 Misc 1 2 3 Input Card IP Input Card IP Hk kk kokk K Place TM Card After Input ID Press Write Success Write Other Card YES NO 24 IBF 630 User Manual www chiyu t com tw 5 User s Menu 5 1 For fingerprint verify user FRI Jan 25 08 GMT 09 00 00 1 1 Verify 1 N Verify 1 1 Verify Place card directly Press E Enter UserID Legal Card _______ s FRI Jan 25 08 GMT 09 00 00 Illegal Card dote Success Fail Unregistered ID FRI Jan 25 08 Name Eric GMT 09 00 00 FRI Jan 25 08 GMT 09 00 00 User Denied User Denied Operation description Method less than 1000 users Place finger for verify Note 1 If you use function key please press function Key first 2 If you want to show name on LCD then you must register Name to BF 660X BF 670X by software 25 IBF 630 User Man
9. user ID terminal ID department function key and time zone gt Query daily first in last out for separate user gt Export the IN OUT log TXT or XLS directly on line gt You can use software program to download the log instantly 2 2 5 Authentication gt gt BF 660X BF 670X supply 5 authentication ways 1 fingerprint 2 RFID 3 Password 4 Fingerprint password 5 fingerprint or password Door access setup finger pin time zone card pin time zone 2 2 6 Real time event gt gt Display user 1 D Name on LCD at authentication time Display fingerprint status grade on LCD at authentication time and supply to fingerprint file 2 2 7 Auxiliary function gt gt Exit button Relay out lock driver IBF 630 User Manual www chiyu t com tw 3 Operation window LCD status Setting Description FRI Jan 25 08 Operation window 10 10 GMT 00 Present Manager F1 Fl Manager login Present finger 1 N Verification Scanning FRI Jan 25 08 ID Input unregistered ID 10 10 GMT 00 User Denied Present finger ID 1 1 Verification fingerprint Scanning User Password ID 1 1 Verification password Solo okk ok Name Eric Place Card Directly Verify success ID 1164752000 08 30 User Denied Ilegal card O Function key description E E Number key Confirm Cancel Page up Enter Administrator Mode No use Delete B
10. 4 2 3 2 1 Add Manager LCD status Key Setting Description 1 FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 2 Del Manager 7 Present card 2 Present Manager Enter password Enter 6 digit password default 111111 value is 111111 3 1 User 2 2 Setting 3 Reset 4 Misc 4 1 Data amp Time 3 2 Security Level 3 Administrator 4 IP Config 5 1 Login P W 2 2 Set Manager 6 1 Add Manager 1 Enter User ID No Or input id 8 Present card Reg Success Or input id AR Reg Success 8 1 Present card Or input id Hk kk kok UnReged User UnReged User 17 IBF 630 User Manual www chiyu t com tw 4 2 3 2 2 Del Manager LCD status Key Setting Description 1 FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 Present Manager Enter password 111111 Enter 6 digit password default value is 111111 1 User Setting Reset A W N Misc 2 1 Data amp Time Security Level Administrator IP Config Login P W R W N Rh 2 Set Manager 1 Add Manager 2 Del Manager Present card Or input id Enter User ID No Present card Or input id EEES Del Success 7 1 Present card Or input id oi ole kk kok UnReged User UnReged User 18 IBF 630 User Manual www chiyu t com tw 4 2 4 IP Config Set IP data of BF 630
11. BF 630 Series User s Manual 2008 01 28 CHIYU TECHNOLOGY CO LTD http www chiyu t com tw TEL 886 5 2325465 IBF 630 User Manual www chiyu t com tw 1 2 Table of Contents About BE 630 SERTE Sousa cnica iin 3 Features ini a 3 2 1 Character E EEE a 3 2 2 Support functions inci A ia b y e dank KANA Kewek h k n 4 2 2 1 User management iln slsb sss xa ri y Li ki s kan ka se ka d k En k on da k l dak een DAR vak b ER N H Sek a b 4 252 2 System MAA 4 2 2 3 Door mod sienien aiei ierindas nesie ida ia desaladora 5 2 2 4 j oy E E Dio EE lara r a 5 2 2 5 Authentication saeta 5 2 2 6 Realtime cretino a ia 5 221 Auxiliary Function pci is 5 Operation WINdOWs sisareni a e de ies atte 6 Administrator Men N ooeoeeOAOAOoA e nw wm edo aai 7 4 1 L Sis E E S r E E 8 4 1 1 Add Usei ganon aaah n yara bala ld ies inte dd 8 4 1 2 Delet User Delet One User vent tata 13 4 1 3 Active User Set user s verify typen 44d sis na deste lan M der Ea ML Kani a Bata k bak al alia 14 4 1 4 Deactive User Closed user s verify type kereke keke keke 14 4 2 SAna Pls D slog bolsa e as saba ALA a aa 15 4 2 1 Data amp Time Set time date and week of BIF O30 ee eee 15 4 2 2 Security Level Set system security level LL eee keke kek 15 4 2 3 AIM TOA ek E VAR ee Ru VE SA YER DES KN E SE WAR A RES A 16 4 2 4 IP Config Set IP data of BF
12. User password Setting Success AR Reg Success IBF 630 User Manual www chiyu t com tw 4 1 1 3 Card verify user LCD status Key Setting Description FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window Present Manager Enter password 111111 Enter 6 digit password default value is 111111 1 User 2 Setting 3 Reset 4 Misc 1 5 1 1 Add User 2 Delet User 3 Active User 4 Deactive User Present card Or input id Reg already Modify user YES NO Present card Or input id 0001968461 Place card directly Go to 6 Go to 4 Reg finger YES NO Reg password YES NO Only Reg User YES NO 10 Only Reg User YES NO Reg Success Setting Success 10 IBF 630 User Manual www chiyu t com tw 4 1 1 4 Fingerprint Password verify user LCD status Key Setting Description 1 FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 2 Present Manager Enter password Enter 6 digit password default 111111 value is 111111 3 1 User 1 2 Setting 3 Reset 4 Misc 4 1 Add User 1 2 Delet User 3 Active User 4 Deactive User 5 Present card SIRES Press user ID No Or input id 5 1 Reg already Go to 6 Modify user x Go to 4 YES NO 6 Reg finger YES NO 7 Prese
13. ackspace No use u BEBEBRI bell IBF 630 User Manual www chiyu t com tw 4 Administrator Menu Administrator menu allows new user registration and deletion and system configuration Press F1 twice to enter O Enter Administrator Mode LCD status Key Setting amp Description FRI Jan 25 08 10 10 GMT 00 Operation window FI Fl Present Manager Enter password 111111 1 User Correct 2 Setting 3 Reset 4 Misc Present Manager KK kok KK Password Error Error password O Function List 1 User 1 Add User 2 Delet User Del One User 3 Active User 4 Deactive User 2 Setting 1 Data amp Time 2 Security Level 3 Administrator 1 Login P W 2 Set Manager 1 Add Manager 2 Del Manager 4 IP Config 3 Reset 4 Misc 1 Reset User Del All User 1 User amp Log 2 Reset Logs 3 IP Config Reset IP Congig 4 Reset Group Del GP TZ HD 2 BF20 485 Reade 3 Set TM Card 1 Init TM Card 2 Write TM Card IBF 630 User Manual www chiyu t com tw 4 1 User 4 1 1 Add User 4 1 1 1 Fingerprint verify user 1 or 2 templates LCD status Key Setting Description 1 FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window 2 Present Manager 111111 Enter 6 digit password default value is 111111 3 1 User 2 Setting 3 Reset 4
14. ard Or input id H KKAR ft Press user ID No Or Place card directly Status Active Present card Or input id UnReged User UnReged User 4 1 4 Deactive User Closed user s verify type LCD status Key Setting Description 1 FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window 2 Present Manager 3 1 User 2 Setting 3 Reset 4 Misc Enter password 111111 1 Enter 6 digit password default value is 111111 4 1 Add User 2 Delet User 3 Active User 4 Deactive User 5 Present card Or input id AAA 2 Press user ID No Or Place card directly Status Deactive 7 Present card Or input id UnReged User 14 UnReged User IBF 630 User Manual www chiyu t com tw 4 2 Setting 4 2 1 Data amp Time Set time date and week of BF 630 LCD status Key Setting Description FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 Present Manager Enter password Enter 6 digit password default 111111 value is 111111 1 User 2 2 Setting 3 Reset 4 Misc 1 Data amp Time 1 2 Security Level 3 Administrator 4 IP Config Input Time 24h HHMMSS Enter time HHMMSS Input Date YYMMDD Enter date YYMMDD Input Day 2 Enter week 1 7 4 2 2 Security Level Set system security level High security level will decrease FAR false acceptanc
15. ctro static discharge keke keke ek erkeke kk keke 29 6 4 Communication nissan 29 6 5 DIVISA aS BIS As es ia 30 6 6 CAP ed 30 6 7 LOS SOY MEMOLY Ca A 30 6 8 DIMENSIONS dd io 30 6 9 DH DD dara r ra 30 6 10 Authentication Macia adds bolos bio dada 30 6 11 False Rejection Remite di 30 6 12 False Acceptance Rat is sunssannu nsubsbkahomma dbaslinusdamaniub kaubl 30 6 13 Fingerprint data siZe cinc nt 30 6 14 BEN AEE E E E A AEE E E E E E EA EE 30 6 15 IBIES I ENEAN EE E E E E E as 30 7 POStSCEIpt ERATA TA A RT 31 7 1 Note ia 31 7 2 External cOnne Cloris y As ardilla B ka H RAE u kire k Baal de ds 31 1 3 Connection expli ii aia 32 IBF 630 User Manual www chiyu t com tw 1 About BF 630 SERIES BF 630 Series is developed to manage entrance security work place time and attendance over work time verification and other situation requiring the presence of the authorized personnel Our fingerprint ID technology bypasses problems of existing security solutions such as security cards and keypad locks BF 630 Series supports various I O protocols Within 1 Card Reader 128 X 64 pixel LCD screen 10 push buttons 6 function keys 1 bell key and 1 buzzer These equipments make BF 630 SERIES user friendly 2 Features 2 1 Characteristics O Fingerprint identification enhances security Existing security measures such as security cards system and keypad locks are prone to breach by una
16. e rate while increasing FRR false rejection rate Oppositely lower security level will increase FAR while decreasing FRR 1 2 3 4 5 LOW lt gt HIGH LCD status Key Setting Description FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 Present Manager Enter password 111111 Enter 6 digit password default value is 111111 User Setting Reset 2 1 2 3 4 Misc 1 Data amp Time 2 Security Level 3 Administrator 4 IP Config Security level 1 5 Current Level 2 Set Success 3 Setring level 15 IBF 630 User Manual www chiyu t com tw 4 2 3 Administrator 4 2 3 1 Login P W Change system password LCD status Key Setting Description FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window Present Manager Enter password 111111 Enter 6 digit password default value is 111111 1 User Setting Reset R W N Misc 2 1 Data amp Time Security Level Administrator IP Config R W N 1 Login P W 2 Set Manager Input New P W Input New P W Again HARIAN ft EEKE E Press New P W Enter Again Input New P W Again Hk kk kok P W Set Success Match Input New P W Again kk kk kok Input P W Error Mismatch 16 IBF 630 User Manual www chiyu t com tw 4 2 3 2 Set Manager
17. gt Finger sensor module gt Build In Card Reader 6 2 Power Supply 6 2 1 Voltage gt 9Vto 30V DC 6 2 2 Current gt Current power consumption 300Ma 12V gt Maximum power consumption 500Ma 12V 6 3 Environment 6 3 1 Temperature and humidity Operating temperature 0 C to 55 C Storage temperature 20 C to 85 C Operating humidity 0 to 95 V V V Y Storage humidity 0 to 95 6 3 2 Immunity to electro static discharge gt Serial port 15kv ESD gt Ethernet port 1 5kv 6 4 Communication gt 1 RJ 45 port 10 100M gt 1RS 232 port gt 1RS 485 port gt Meet RS232C RS485 specifications 29 IBF 630 User Manual www chiyu t com tw 6 5 Drivers gt 2 Relay Out COM NO NC 6 6 Capacity gt 950 Persons 1900 Templates 2 Templates per User 6 7 Log entry memory gt 32768 Transactions 6 8 Dimensions gt 145 w X 125 H X 33 D mm 6 9 Weight gt 330g 6 10 Authentication time gt Average shorter than 2 second 6 11 False Rejection Rate gt Less than 0 01 6 12 False Acceptance Rate gt Less than 0 001 6 13 Fingerprint data size gt 352 Byte 6 14 Input gt 10 number keys 6 function keys 1 bell 6 15 Display gt 1 Buzzer gt 1LCD 128 X 64 pixels 2LED 30 IBF 630 User Manual www chiyu t com tw 7 Postscript 7 1 Note The first thing when you install BF 630 gt Please change the system
18. ing has two security level includes account and password to avoid the setting status revised by a bad intention gt Set terminal ID title on LCD description fingerprint security level maintenance time card ID display format master slave gt Check the slave data in slave list gt Set communication status on the internet such as IP Address Gateway DNS Port Number Host Name gt System clock setup you can setup clock immediately by your hand or connect to the time server to revise everyday IBF 630 User Manual www chiyu t com tw V V V WV Support 40 IN OUT trigger setup Support 16 ring setup Backup and restore the user s data directly Import all user s list directly on the internet 2 2 3 Door mode gt 255 time set 255 time zone setup 200 group list 100 holiday setup gt Expand 16 reader to process 8 doors security time and attendance at most gt You can aimed at some entrance exit setup location relay trigger lock release time zone exit button time zone anti pass back level lock release time and door open delay time by connect to door lock controller or elevator controller gt You can define some entrance exit floor parking area and attendance control by system gt Door status on line gt Configure and read door mode normal forced open forced close by real situation 2 2 4 Log gt Access log user or employee can query their access log by any computer gt Query by
19. le configurations Utilizing Weigand RS232 RS485 protocol to contain with an ACU Also direct connection to a PC is possible via TCP IP or RS232 RS485 protocol when software library bundled Because BF 660X BF 670X content RTC and log management capabilities up to 65 000 records entrance security and other event management are possible without an ACU Besides BF 660X BF 670X involves clock on time and record ability 65000 logs at most so it can be used to entrance security or other stand alone modules O Expandable and Convenience BF 660X BF 670X has Chinese Http Server inside and that makes you revise the setting on line download data manage employees and maintain the system conveniently It also reserved sixteen I O expand points for integrated with other system 2 2 Support functions 2 2 1 User management gt Register a user provide 4 type of register 1 Fingerprint 2 Password 3 RFID 4 Fingerprint Password Support 128 designations and departments for set Manager can depend on the real supply situation for the limit period of employee one by one Manage the entrance security and time by group The status of employee can activate or deactivate V V V V WV Supply employees data you can check every employee s number name status and the way of identification gt Delete a user or all users 2 2 2 System management gt Chinese Http server inside can use IE to revise the data and manage user on line gt System sett
20. nger Place anther finger on the sensor Scanning 13 Processing 14 FP 85 14 1 Processing Reg Failed Reg Failed Back 4 15 Reg password YES NO 16 User password EE Te Press user password no Enter 6 digit password 17 Write Mifare If No use YES NO i 18 Write Mifare Setting Success YES NO Reg Success 12 IBF 630 User Manual www chiyu t com tw 4 1 2 Delet User Delet One User LCD status Key Setting Description FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window Present Manager Enter password 111111 Enter 6 digit password default value is 111111 1 User 2 Setting 3 Reset 4 Misc 1 1 Add User 2 Delet User 3 Active User 4 Deactive User Present card Or input id Present card Or input id KKK KKK Del Success Present card Or input id UnReged User o Press user ID No Or Place card directly UnReged User 13 IBF 630 User Manual www chiyu t com tw 4 1 3 Active User Set user s verify type LCD status Key Setting Description 1 FRI Jan 25 08 10 10 GMT 00 F1 Fl Operation window 2 Present Manager Enter password 111111 Enter 6 digit password default value is 111111 3 1 User 2 Setting 3 Reset 4 Misc 1 4 1 Add User 2 Delet User 3 Active User 4 Deactive User 5 Present c
21. nt finger Place finger on the sensor Scanning Processing wait 9 FP 73 9 1 Processing Reg Failed Reg Failed Back 4 10 Reg other finger If no use go tol4 YES NO Setting Password verify user 11 Present finger Place anther finger on the sensor Scanning 12 Processing 13 FP 85 13 1 Processing Reg Failed Reg Failed Back 4 14 Reg password YES NO 15 User password REDE H Press user password no Enter 6 digit password 16 Write Mifare i YES NO 17 Write Mifare Setting Success YES NO Reg Success 11 IBF 630 User Manual www chiyu t com tw 4 1 1 5 Card Fingerprint Password verify user LCD status Key Setting Description 1 FRI Jan 25 08 F1 Fl Operation window 10 10 GMT 00 2 Present Manager Enter password Enter 6 digit password default 111111 value is 111111 3 1 User 1 2 Setting 3 Reset 4 Misc 4 1 Add User 1 2 Delet User 3 Active User 4 Deactive User 5 Present card Place card directly Or input id 5 1 Reg already Go to 6 Modify user Go to 4 YES NO 6 Present card Or input id 0001968461 7 Reg finger YES NO 8 Present finger Place finger on the sensor Scanning 9 Processing wait 10 FP 73 10 1 Processing Reg Failed Reg Failed Back 4 11 Reg other finger If no use YES NO go tol4 Setting Password verify user 12 Present fi
22. password first BF 630 s password is fixed at 111111 initially It makes a security problem Please do these when you have the problem for verification gt Cleaning your finger first then do it again gt Don t move your finger when you put your finger on the BF 630 s sensor Please do these when BF 660X BF 670X has out of function gt Power off and power on again so initialize BF 630 After initializing BF 630 if it has same status still please calls on Chiyu s service center 7 2 External connector BF 630 830 V IN HDC 9 30V 485 n 485 1 485 205 NO Exit Button IN 1 Fire Alarm GND abi Wiegand Output Relay Output 31 IBF 630 User Manual www chiyu t com tw 7 3 Connection example BF 660X or BF 670X Li rusa vu 7 lt 1 mus j in out RJ 45 HUB N Door 2 44444 RJ 45 Q lt a Door 8 O To Be a FP Reader 485 TCP IP RS 485 Q BF 20 RS 485 BF 20 BF e BF 660CS BF 670E Q 20 32 IBF 630 User Manual www chiyu t com tw O To Bea Standalone Unit When needs external WG Reader for OUT then BF20 is needed DOOR SENSOR EXIT BUTTON EM LOCK BF 603EW When using Exit Button for OUT and no need door sensor EXIT BUTTON a EM LOCK
23. ual www chiyu t com tw 5 2 For password verify user 1 1 verify FRI Jan 25 08 09 OOs 1 1 Verify 1 1 Verify Place card directly Enter UserID Legal Card ________ User Password FRI Jan 25 08 09 OOsoo _ Illegal Card see Success FRI Jan 25 08 Eri ser Password FRI Jan 25 08 09 00 00 p E 09 000 _ User Denied a User Denied Operation description 1 1 verify gt max 5000 users Method A Method B 1 Enter User ID Place sensor card on the coil directly 2 Place finger for verify Enter password 6 10 digit 3 Enter Password No Press Note 1 If you use function key please press function Key first 2 If you want to show name on LCD then you must register Name to BF 660X BF 670X by software 26 BF 630 User Manual www chiyu t com tw 5 3 For card verify user 1 N verify FRI Jan 25 08 09 OOs 1 N verify Place sensor card on the coil directly FRI Jan 25 08 Legal Card 09 OOsoo _ User Denied Illegal Card Operation description 1 N verify gt max 5000 users Method Place sensor card on the coil directly Note 1 If you use function key please press function Key first 2 If you want to show name on LCD then you must register Name to BF 660X BF 670X by software 27 BF 630 User Manual www chiyu t com tw 5 4 For fingerprint password verify user
24. uthorized persons through card duplication or disclosure of set security code Fingerprint ID system can truly restrict security access only to those authorized persons O Reliable fingerprint ID algorithm Our in company developed fingerprint ID algorithm has minimized False Rejection Rate and False Acceptance Rate O Entrance security time and attendance over time management and other applications Fingerprint ID system allows for entrance security work place time and attendance over time work Also situations that require the presence of the authorized persons at a secured point can take advantage of our fingerprint ID system O Special function keys may be configured to time and attendance and entrance access management 4 programmable function keys can be used to manage time and attendance One BF 660X BF 670X can be adapted to manage many different kinds of work involving site security control and time and attendance O Low cost of system maintenance Existing IC cards require new issuance of cards with addition of new users and lost of cards This becomes unnecessary with fingerprint ID system System maintenance can be lowered to negligible levels when compared to other solutions IBF 630 User Manual www chiyu t com tw O Use of stand alone modules and working in conjunction with an ACU BF 660X BF 670X entrance control system may be used as stand alone units to control entrance traffic or in multiple modu