Home

T-862++ Illustrated explaining

image

Contents

1. Focus holder and others IR Lamp Cooling Fan Cell guide Focus holder control knob Focus holder Fasten nut for focus holder Fasten nut for steady ring steady ring Http www tech168 cn IRDA Workstation T862 User Manual Infrared Work Station Unpacking and Assembly 1 Unpack and remove the T 862 two 2 major assemblies and minor components from the styrofoam packaging material and set aside Note The Infrared Head Body Mounting and Focus Assembly will be installed in the T 862 chassis later 2 Inventory all Items confirm no parts are missing If parts are missing call 0086 538 6138575 3 Install the cell guide Loosen the fasten nut of the focus holder first then install the cell guide The method to install the cell guide as follows N 4 Install the steady ring Loosen the fasten nut for steady ring first installed the steady ring as The cell guide follows then fasten the nut Steady ring The direction to fasten the steady ring 5 Assemble wholly O Relax the fasten nut of focus holder Install the cell guide on the relevant nut screw the cell guide on the nut as follows O H Rotation the fasten nut of focus holder to fix the focus holder O Rip off the protective film of the filter r 22 Direction of Rotation Http www tech168 cn 7 IRDA Workstation T862 User Manual 6 Connect the IR Lamp
2. Check if the connection wire of the lamp body and the 936 Iron is ok 2 Locate and attach the power cable to the rear of the re work station 3 Confirm all front panel rocker switches are off 4 Place the rear AC Power Switch in the ON Position 5 Allow the T 862 Power On Self Test POST to complete 6 Temperature set points will display last value used 7 Place the target PC Board on the slip rack and orient to close proximity of estimated position of focused Infrared light Http www tech168 cn 9 IRDA Workstation T862 User Manual 8 Adjust the T 862 Infrared light system height allow 20 30mm from lens end to PC board target component 9 Turn on the two switches They control warm up plate and light system 3 PC Board Component Removal and Replacement 1 Put the PCB board onto the holder 2 Turn on the switch of the pre heat dish and set up the temperature 3 Turn on the switch of the IR Lamp Regulate the temperature the temperature must be warm enough to allow the solder to be liquefied focus the Infrared light on the chip to be removed 4 Soldering a chip 1 Clean the target pad with the brush 2 Then put the solder ball and a flat of solder flux on the target pad 3 Turn on the switch of the pre heat dish and set up the temperature 4 Turn on the switch of the IR Lamp Regulate the temperature the temperature must be warm enough to allow the solder to be liquefied focus the In
3. Features Unlike Air Re Work systems The T 862 uses an Infrared source and optics to target heat to individual components without dislodging other SMT parts by way of eddies air currents Infrared soldering technology with independent exploration capabilities via three 3 focus lenses which are included with the package Technician focused infrared heat is easy to target most component removal replacement and re work The Workstation has a 120 X120mm a 650W controlled Pre heating System Infrared heat source bulbs are long lived in expensive and easily replaced Processor controlled set point regulated temperatures with thermocouple feed back Integrated and adjustable Infrared IR eye protection Can suitable for the entire component especially Micro BGA component The T 862 system also contains a temperature controlled touch up iron and stand Extra soldering tools are not necessary to solder unsolder and re work Surface Mount Technology SMT components 15 35cm in size Training is illustrated in factory provided video Http www tech168 cn 2 IRDA Workstation T862 User Manual Technical parameter AC220V 50Hz Working Voltage AC110V 60Hz Output power 800W Infra red lamp body temperature adjustable 100 C 350 C Preheating dish temperature adjustable 60 C 200 C Components Sant aaa T T 862 Chassis T 862 Chassis PCB Board holder a eas searingitonvack oo SCS L
4. body and the 936 Iron with the chassis Insert the pin into the relevant jack Rotate rightward to fix it 7 Attach IR Eye protective filter with the supplied screw and nut Http www tech168 cn IRDA Workstation T862 User Manual T 862 Operation PC Board Support T 862 chassis 1 Locate choose and attach the appropriate lens The usable of the lenses diameter are 28mm 38mm 48mm 1 When the area of the chips is below 15mm 15mm please choose the IR lamp temperature about 160 240 C and choose the lens which D 28mm to avoid destroying other places usually it will take you about 20 40seconds 2 When the area of the chips is between 15mm 15mm and 30mm 30mm please choose the IR lamp temperature about 240 320 C and choose the lens which D 38mm to avoid destroying other places usually it will take you about 30 60seconds 3 When the area of the chips is above 30mm 30mm please choose the IR lamp temperature 350 C Attention you should turn on the pre heat dish first and set up the temperature about 150 200 C wait 3 5minutes to allow the temperature steady on the set up temperature and choose the lens which D 48mmto avoid destroying other places and keep the lamp body direct light You should control the time carefully to avoid burning the chips Warning The light system will shoot straightly Please pay more attention to yourself control time to avoid burning out 2 Open the machine 1
5. IRDA WELDER User Manual Model T862 Talan Puhui technology CO LTD www contactelectric ro 1 2 Technical Parameter and ComponenisS aa 3 T 862 Illustrated ExplainatioOn aaa 4 Infrared Work Station Unpacking and Assembly 5 T 862 Operation method aaa 6 Maintenance and Warning akan IRDA Workstation T862 User Manual CATALOGUE Aa AN a AAA PA A AAA eraa NE BAN 1 The Whole Machine ea kaka 2 Front panel and Rear panel 3 IR Lamp Body Focus Holder and Others 1 Unpack the packaging ccccccee cee cee cesses see seeeaeeaeeees 2 GMECK MIS EMIS inuna a ana sa Ana 3 Install the sCe lig We esate ces a thea Sen BNN 4 Install the steady RIng aaa 5 Assemble Wholly 0 002 ccc cee cence cee cee asas 6 Connect the Tie Wire of the Lamp and the Iron 7 Attach the IR Filter ad do oat ag ie ued ad DCnoose The lens peresen e mai 2 Open the machine andalan ee mens endah aka aa 3 Remove the Chip ma Baal Sana 4 Soldering the ChIP bang covscesansencsdaxteieessmags 5 The use of the 936 searing irOn kn Http www tech168 cn 10 10 11 12 IRDA Workstation T862 User Manual
6. amp Body and Lens D 28mm 1 Lens D 38mm Tenda TI o Berangan IT CS cage o oo o o Focust a S Focus holder control knob a Fasten nutforfocusholder 1 Seym o Fasten nut for steady ring 1 Power Cable 110VAC or m SmmFuse 10R250vA0 Spar 1 O On Be NN Ti rot 6 j D 28mm D 38mm D 48mm Shipped On Lamp Body Http www tech168 cn 3 IRDA Workstation T862 User Manual T 862 Illustrated explaining 1 The whole machine The end covering Fan Protector Protection Cover Cell guide Focus holder Eye Protection IR Filter Preheat dish 936 searing iron Lens for infrared lamp Holder for PCB board 936searing iron rack Chassis working bench Front panel Http www tech168 cn 4 IRDA Workstation T862 User Manual 2 Front Panel The screen displayed the The screen displayed the peak temperature temperature of the 936 iron of the IR lamp The screen displayed the temperature of the preheat dish Infrared Lamp Switch Touch UP Iron Switch Preheat Switch T 862 IRDA GOLDING TAG SYWDABGA Rework Sialian Temperature Set Point Entry Buttons Rear Panel Jack for universal power line Jack for 936Iron Jack for Lamp body AC 220V IRDA LIGHT GUN Main Power Switch Http www tech168 cn 5 IRDA Workstation T862 User Manual 3 Infrared Lamp
7. e to fire or electrical overload Disconnect the AC Power Plug when not in use When using it is of high temperature Do NOT allow children or the un trained to touch the T 862 12
8. frared light on the chip to be solder Http www tech168 cn 10 IRDA Workstation T862 User Manual 5 Wait to allow the Infrared lamp to heat the solder flux to work as the solder balls on the target chip pad reaches liquid temperature Use tweezers or a vacuum device to place the chip target position Once the solder liquefies the chip will be sold automatically After cooling the chip pick up the PCB board check if itis ok If not re operate 5 The use of the 936 searing iron It can be used separately But be sure it must be connect with the chassis If the component is too small you needn t use the IR lamp the 936 searing iron is enough Open the switch of the 936 searing iron set up the temperature then use it as you want Http www tech168 cn 11 IRDA Workstation T862 User Manual Maintenance V Atalltimes Insure the light body cooling fan is unobstructed and clean y Use a little machine oil Lubricate the focus holder and cell guide to inhibit rusting keep them ease to operate Warning The T 862 System creates temperatures in excess of high degrees via Infrared Light Wear appropriate eye protection or any device within the T 862 when using it After use Do not cut the power immediately confirm the light body is cool to touch Turn off the power switch then place the system in airiness amp safety storage Do NOT use this system or any associated device in an environment conduciv