Home
CustomAir by RAMVAC Compressor User Manual
Contents
1. Provides a 24VAC low voltage signal to the remote panel Accepts the remote switch input Controls the dryer purge function Communicates with the RAMVAC OWL Runs the heat exchanger fan while the compressor motor s are on Flashes the maintenance light on the remote switch or OWL controller when filter maintenance is due Keeps track of run time hours with the hour meter Motors are protected with a 20 amp slow blow fuse on each leg Motor 1 Motor 2 Hour Meter Heat Exchanger Fan _ amp Purge Valves T c la N Line Voltage Fuse 20 amp slow blow 2 i dn iL L Zl Pole in Wier Geet eli From Tank O O SOF_7 5 1 07 04 Effective date 02 Jul 08 CustomAir ramvac OPERATION User Guide Low Voltage Remote Switching Use to turn system on and off from a remote location Your CustomAir sa ac compressor is manufactured to continuously cycle as required throughout the workday Power off at end of the day Illuminated Remote Panel RAMVAC OWL Non llluminated remote Switches e Switch light is steady on when system is running normally e LEDs beside corresponding switch Non illuminated switches Switch light flashes for maintenance or one of the heads illuminated when running provide no indication for has been disabled by the disable button on the C1 Control OWL gives complete breakdown of system status data on selected equipment Recommended Switching R
2. date of installation Please note the following additional terms of our warranty and return policy e Warranties cover manufacturing defects only and do not cover defects resulting from abuse improper handling cleaning care or maintenance normal wear and tear or non observance of operating maintenance or installation instructions Failure to use authorized parts or an authorized repair facility voids this warranty e Liability is limited to repair or replacement of the defective product at our sole discretion All other liabilities in particular liability for damages including without limitation consequential or incidental damages are excluded e This warranty is in lieu of all other warranties expressed or implied including ANY IMPLIED warranties of merchantability or fitness for a particular purpose no employee representative or dealer is authorized to change this warranty in any way or to grant any other warranty WARRANTY REPAIRS Parts repaired or replaced on a product that is in warranty will be warranteed for the duration of that product s original warranty NON WARRANTY REPAIRS The warranty on parts either repaired or replaced on an out of warranty product will cover the repaired part only and will be for the timeframe of a new parts warranty period PRODUCT RETURN Opened products or product returns more than a year old cannot be returned for credit There will be a 15 25 00 minimum restocking charge on all items auth
3. 20 x205 x265 9 x 26 5 PKA X 22 x PKA DIMENSIONS wxdxh 25 xX 20 5 x 30 30 x 27 x 30 30 x 27 x 30 30 x 27 x 30 WEIGHT 136 Ibs 166 Ibs 174 lbs 182 Ibs 238 Ibs TANK SIZE 10 gallon 10 gallon 10 gallon 10 gallon 10 a TE TT SCFM 100 Ibs vous Note All motors used are 1 phase 60Hz motors Ensure compliance with all National and Local codes Compressor Model Numbering System XXXX X compressor series of motors per unit t D Dual compressor voltage Tri pr 115V g T Triple 2 230V of users SOF_7 5 1 07 04 Page 11 Effective date 02 Jul 08 User Guide SOUND COVER INSTALLATION CustomAir ramvac Sound Cover Installation on Single Head Compressor 4 Remove the 4 bolts holding the mounting bracket to the Sound Cover and set bolts aside to reuse Bolts 2 on each side Mounting Bracket Intake Filter Fresh Air Piping 2 Remove Fresh Air Intake piping if present 3 Secure Mounting Bracket with 4 bolts to the compressor base 4 Thread Fresh Air Intake piping through hole in the Mounting Bracket and attach to intake filter Bolts 2 on each side 5 Align the Sound Cover over the compressor and attach to the mounting bracket using the 4 bolts previously set aside Page 12 SOF_7 5 1 07 04 Effective date 02 Jul 08 User Guide CustomA ir ramvac Notes SOF_7 5 1 07 04 Page 13 Effective date 02 Jul 08 CustomAir
4. 7 Nina p li ll MTT is illite i j miliy gt gt Q CustomAir Dental Compressed Air System USER GUIDE Installation and Maintenance Manual For 1000 Series with C1 Control User Guide CustomA ir ramvac Thank you for selecting a CustomAir sac Dental Compressed Air System to serve your dental facility CustomAi rauc Compressors use proven oil less technology to set new standards in compressed air system performance durability and economy Invest a few minutes of your time and 1 Read the Maintenance section in this guide Use these simple preventive procedures that will allow your compressor to reach its service life potential 2 Read the Operation section in this guide Find out how to best control your compressor and put its safety features to work for you 3 Initiate the warranty Check inside the back cover to review our warranty commitment to you and what you need to do to receive warranty coverage To initiate the warranty you must 1 Complete and return the Installation Checklist to RAMVAC or 2 Visit our website at www ramvac com and complete the warranty initiation form All of us at RAMVAC appreciate your business and take a personal interest in your satisfaction Please let us know how the system is working for you Just give us a Call or stop by one of our dental show exhibits Please accept my personal invitation to visit our manufacturing facility in
5. AMVAC Remote 1 Panel or 2 C1 Control equivelent with J Terminals illuminated 24VAC Switch C1 Control OWL Connection Terminals G RAMVAC Panel or Alternative Switch gt gt Connection Alternative Switching Toggle Switch h aaa H ot a d F C1 Control non l umina e gt H Terminals switch option Note Maximum wire length for low voltage 18 gauge wire 500 feet Vac Switch F 24 VAC Note High Voltage switching is an G 24 VAC option but not recommended Contact Common C1 Controller Illuminated Remote Switch Terminals SOF_7 5 1 07 04 Page 7 Effective date 02 Jul 08 User Guide MAINTENANCE CustomAir ramvac Maintenance Overview CustomAir sawv c compressor preventive maintenance is simple clean and inexpensive It can help ensure your system provides years of predictable performance Key points for trouble free operation e Check the Coalescing and Particulate filter indicator every month e Keep compressor clean and free of dirt e Keep area surrounding compressor free of debris e Maintain a controlled ambient temperature between recommended levels High temperatures will shorten the life of the air compressor Follow the recommended preventative maintenance schedule Preventive Maintenance Schedule This is a recommended schedule for a compressor in a clean dry environment Any site other than specified will decrease the maintenance time exponentially
6. ana rd lt Zrrrardrd E Page 9 Mpe ing DIYOT rr rbrbrbr ard ll A OE E merr Page 10 Testing Salety VAIVES JK EEE EREE E EARE E aR Page 10 Testing Compressor 1Ol LOAKS 22 cacoscenrsescacinsssssnwnesnadsassacaetameasanscanawiusweuetcuweseseovensegenseieselsdaaes otandgmmaneee Page 10 wz Kal ONS irren E E A E N Page 11 Sound Cover Installation Sound Cover Installation on Single Head CompreSsol cscecececcccecscscsccccccccecscscsceccccccecscscecececcccececsces Page 12 Sound Cover Installation on Dual Head Compressol cscscsesscscscscscscsecscscscscscsecscscscecscsesscscscscscssseasesens Page 14 TOUDI MOO ONIN aser enese EE E E acevawambeynnersianuccesusesece aver E EE E E E Page 16 WAN e oirinn E A O Inside Back Cover System Schematic Remote Panel Breaker Box Fresh air intake Low Voltage pa 2 fr r 2 ES a ni s l e Ae iva Recepticle Mi r r fg kr RU TT kj PE J amp kr Facility Plumbing i he Ps Ra es a i C1 Control SOF_7 5 1 07 04 Effective date 02 Jul 08 User Guide Page 1 User Guide UNPACKING CustomA ir ramvac Unpacking Instructions for the Custom Air c Compressor 1 Carefully remove the shipping carton from the pallet containing the compressor 2 Visually inspect the entire compressor for shipping damage a Visually inspect the motor isolator mounts for tearing b If shipping damage is found immediately contact the freight carri
7. at 866 DTE INFO lf we cannot resolve the issue by telephone we will arrange for a representative to contact you or suggest that the product be returned to our fac tory for inspection lf product return or repair is required we will provide you with a Return Authorization number and shipping instructions to return the product to the proper facility If the product is under warranty we will ask you to provide proof of purchase such as a copy of your invoice Please be sure to include the Return Authorization number on the package you are returning Products returned without a return authorization number cannot be repaired Freight costs for product returns are the responsibility of the customer Products under warranty will be repaired or replaced at our sole discretion and returned at our expense Products outside the warranty limits will be repaired and returned with costs invoiced to the customer We are not responsible for shipping damages We will however help you file a claim with the freight carrier Written repair estimates are available DentalEZ warrants all equipment and parts to be free of defects in material and workmanship under normal usage under the following terms RAMVAC Products Warranty Period RAMVAC Dental Vacuum System 2 Years from date of installation RAMVAC Vacuum Pumps only 10 Years from date of installation RAMVAC OWL 2 Years from date of installation CustomAir y ramvac 6 Years 4200 hours from
8. er and supplier 3 Remove lag screws holding the compressor to shipping pallet 4 Verify additional parts shipped with the compressor a Additional parts shipped with all compressor models Supply Hose 1 4 mpt x 3 8 mpt 6 in length e Drain tubing 3 8 plastic 4 in length Bushing 1 2 mpt x 3 8 fpt b Additional parts shipped with 1022 model only Air Intake tubing 1 2 OD plastic 10 in length A Sound Reduction Cover is available for most models when installed in a sound sensitive area Remember to fill out and mail in the Installation Checklist to intiate the warranty Page 2 SOF_7 5 1 07 04 Effective date 02 Jul 08 CustomAir ramvac INSTALLATION DATA User Guide Placement Indoor use only in a dust free climate controlled room DO NOT install in an enclosed area where ambient temperature could exceed temperature specifications of below 0 C 35 F or above 40 C 104 F while the compressor is running Maintain minimum 6 clearance on sides back and top of all compressors Maintain 12 clearance in front of compressor On the 1029T compressor maintain a 12 clearance on left side for electrical service Compressors are equipped with 4 adjustable rubber feet to ensure unit stands firmly on the floor WARNING DO NOT install on surfaces with more than a 5 incline WARNING To prevent tipping during transport securely fasten unit to shipping pallet CAUTION Dang
9. er of fire or explosion when using flamable substances CAUTION Never leave children unattended when compressor is in use Electrical Follow NEC NFPA 99C and all local codes Compressors are shipped with the appropriate electrical cord with plug Qualified personnel must install a dedicated electrical circuit Motors and C1 Control protection is provided by a 20 amp time delay fuse on each power leg in the C1 1029T compressor motor electrical protection is provided by a 30 amp time delay fuse on each power leg in the Motor Control Box See Specifications for more electrical information WARNING Electrical shock could occur as a result of improper grounding This product must be grounded according to NEC regulations and local codes WARNING Always turn off compressor and remove power plug from outlet when servicing CAUTION Use of an extension cord is not advisable An undersized extension cord will cause a drop in line voltage and loss of power Overheating will result Plumbing Connections Attach drain tubing to fitting on bottom of coalescing filter and direct it into floor drain for disposal of water Connect compressor air outlet to facility plumbing with provided supply hose 1 4 npt x 3 8 npt 6 in length and if necessary a bushing 1 2 mpt x 3 8 fpt Note Pressure regulator is customer supplied Connect Fresh Air Intake uses 1 hose barb to external air source per NFPA 99C recommenda
10. l 08 CustomAir ramvac CustomAir sawvac 1000 series compressor is a Level 3 dental compressed air system The system is run by a state of the art electronic control that provides for continuous operation in a controlled environment Our compressors are built to serve the needs of the dental industry by providing clean dry air and years of reliable service Table of Contents Safety and Regulatory Information cscscsccscscscscscsccscscecscscsescscecscsesescscesececessesenseseeeees Inside Front Cover J Dl OFC ONGC IGS s 5553385355 s ri sa SO E eyd MER wN Ib n Ke KA DE el G sed Pev n eW RO NE pe e Ae divane da Se b EN e Page 1 oud rere REKKKEpNpMNMRRMM RBRBRBRRa aRERRUuRoR DRDRDEEee eee Page 1 NUCH TY YAN DD E E Page 2 he a 5 20 icwsosnassnasensucdiaorsiusctatewenweoetonda sete EEEE EE EEEE N EEE TE EET Page 3 ean altan N TP MM E E E E E E Page 4 Operation Nisa dl bol rh r err vw gt w owrarasRsRg r _i__ Page 5 SING ya ag gt _ eomreo i idt Bae _errmrmrmrmrmmrmm ec mmc Page 5 CP Control F Q U S iryy nans ca e k e PE e Sed E RAN Gene Ml a nuka s n h kan i h W k r d e awae nk ga k e d d Page 6 saow z cc rmn Page Maintenance DDDzoz z roo e w_ r e EEE SEERA Page 8 Preventative Malntenace Sen dU i sil kek elan ekan nen kanek sant NEEE EE Page 8 ar
11. n compressor fittings Leaks in facility air lines Dirty intake filters Dryer malfunction Valves sticking Ambient temperature exceeds 40 C 104 F Compressor not shutting off Leaks in compressor fittings Leaks in facility air lines 1 Condensate in tank 2 Leaks in compressor fittings 3 Leaks in facility air lines Restore line voltage Check the power cord to make sure it is plugged in Check the fuse or breaker panel Check fuse s in the C1 Control or motor control box See Test Compressor for Leaks Test facility air lines for leaks Replace intake filters Contact RAMVAC Contact RAMVAC Lower ambient temperature See symptom Compressor runs but pressure does not increase See Test Compressor for Leaks Test facility air lines for leaks Contact RAMVAC See Test Compressor for Leaks Test facility air lines for leaks SOF_7 5 1 07 04 Effective date 02 Jul 08 CustomA ir ramvac WARRANTY User Guide RAMVAC Product Support Services The DentalEZ Group and its employees are proud of the products we provide to the dental community We stand behind these products with a warranty against defects in material and workmanship as provided below In the event that you experience difficulty with the application or operation of any of our products please contact our customer service department at our expense
12. orized for return When installed operated and maintained in accordance with written instructions RAMVAC Bison Bulldog FLOWCHECK Ramclean and VACHECK are registered trademarks and InfiniTank OWL and SlugBuster are trademark of RAMVAC Dental Products Inc SOF_7 5 1 07 04 Inside Back Cover Effective date 02 Jul 08 SOF_7 5 1 07 04 Effective date 02 Jul 08 3100 First Avenue 800 5 RAMVAC Spearfish SD 57783 FAX 605 642 3776 WWW ramvac com 2008 RAMVAC Dental Products All rights reserved No part of this publication may be copied or distributed transmitted or transcribed in any form or by any means without the expressed written permission of RAMVAC Dental Products Spearfish SD 57783 EXCLUSIVELY FROM Sess FESS d ISO 9001 2000 certified facility ISO 13485 2003 certified facility 3100 FIRST AVENUE SPEARFISH SD 57783 TOLL FREE 800 5 RAMVAC 800 572 6822 PHONE 605 642 4614 FAX 605 642 3776 e mail ramvac ramvac com website www ramvac com A Brand of the ak gt The Integrated Supplier PHONE 866 DTE INFO www dentalez com
13. raining feature that allows the draining of the excess moisture The cool air enters the desiccant style dryer assembly to complete the moisture removal by removing 99 7 of the water vapor from the air Air is directed into the dryer cartridges from one to the other by electronically controlled solenoid valves The timing for the solenoid valves is varied between models and provided by the C1 Control While the air is moving through one cartridge the desiccant in the other cartridge is being dried by air directed through an orifice in the outlet shuttle valve This valve cycle will be noticeable by a short burst of air from the purge valves When the air has left the dryer assembly it goes through a particulate filter to remove any remaining particulates from the air It is then collected in the tank where a pressure gauge displays the tank air pressure The tank pressure is monitored by a pressure transducer in the C1 Control which runs the motors on demand Pressure is factory set to start the compressor at 80 psi and shut off at 100 psi Pressure settings are not adjustable Getting Started CustomA ify rauac 1000 series compressor is easy to operate and maintain Note If Sound Cover was ordered with the compressor see WARNING DO NOT direct air flow toward the body Installing Sound Cover section WARNING Always turn off compressor and remove 1 Verify the compressor is plugged into a dedicated circuit with an power plug from outlet when
14. ramvac SOUND COVER INSTALLATION User Guide Sound Cover Installation on Dual Head Compressor Mounting Bracket 4 Remove the 4 bolts holding the mounting bracket to the Sound Cover and set bolts aside to reuse Fresh Air Intake Bolts 2 on each side Bolts 2 2 Remove Fresh Air Intake piping if present 3 Loosen bolts on fresh air intake Fresh Air Intake 4 Tilt the mounting bracket slightly downward and slide onto the base of the compressor under the fresh air intake 5 Line up the fresh air intake to the hole in the mounting bracket 6 Secure mounting bracket with 4 bolts to the compressor base 7 Tighten bolts on fresh air intake 8 Attach Fresh Air Intake piping Bolts 2 on each side 8 Align the Sound Cover over the compressor and attach to the mounting bracket using the 4 bolts previously set aside Bolts 2 on each side Page 14 SOF_7 5 1 07 04 Effective date 02 Jul 08 CustomA ir ramvac User Guide Notes SOF_7 5 1 07 04 Page 15 Effective date 02 Jul 08 User Guide TROUBLESHOOTING CustomAir ramvac Compressor does not start No power light on C1 Control Compressor runs but pressure does not increase Compressor gets too hot Compressor runs when pressure is not being used Compressor starts and shuts off more fre quently than normal Page 16 1 No line voltage Blown fuse s in the C1 Control or motor box on 1029T Leaks i
15. servicing appropriate electrical outlet 2 Verify the compressor is properly connected to the CAUTION DO NOT attempt to operate the compressor at facility plumbing and fresh air source ambient temperature below 0 C 35 F or 3 Verify the outlet valve is closed above 40 C 104 F 4 Vent pressure gauge a Turn yellow tab on top of gauge from closed to open to vent 5 Push and hold the power button on the C1 Control for approximately 5 seconds to start Note The power light will go off when the button is held 6 Test for leaks See Testing Compressor for Leaks 7 Turn the shut off valve to open 8 The compressor installation is complete Turn yellow tab from CLOSED to OPEN to vent gauge Turn from left to right SOF_7 5 1 07 04 Page 5 Effective date 02 Jul 08 User Guide OPERATION CustomAir ramvac Status lights Jt T0 E ees ira Page 6 C1 Control Features Status Lights Power Status Green light is on when line voltage is present Green light flashes when one motor has been disabled by motor disable button Motor 1 Status Green light is on when motor is running Amber light is on when motor is disabled Motor 2 Status Green light is on when motor is running Amber light is on when motor is disabled Monitors the pressure transducer to start and stop the motors depending on demand 1 Turns motors off at 100 psi 2 Turns motors on at 80 psi 2nd motor will start with a 1 second delay
16. t Safety Valves 1 Run compressor until 45 psi shows on the gauge Pressure Gauge 2 While the compressor is still running pull ring on safety valve TENA PE S Note A loud burst of escaping air will be heard when air is released from the safety valve 3 lf no air comes out of safety valve the valve is defective and valve must be replaced immediately Caution Bleed air from system before servicing 4 Repeat procedure for each safety valve one for each head plus one at tank inlet 5 Return compressor to service Test Compressor for Leaks ERN Close valve to facility plumbing Run compressor until it shuts off at 100 psi Turn compressor off with the power button on the C1 Control Let compressor set for 5 minutes lf the pressure drop is more than 5 psi in a 5 minute time period leaks must be repaired Repair if needed 7 Open valve to facility plumbing 8 Return compressor to service aS SS LS o gt Page 10 SOF_7 5 1 07 04 Effective date 02 Jul 08 CustomAir eamvac SPECIFICATIONS User Guide Specifications MODEL met 1013D 1023D 1027D 1029T MOTOR RE JB aa 230V 115V 230V 230V 230V 230V 208 253 208 253 208 253 208 253 208 253 Recommended 12 0 amps AAT PONER 5 1 amps j 8 4 amps 9 5 amps 15 4 amps CONSUMPTION 5 9 amps UNIT koa Sire e Ml 24 205 28 X 24 205 28 o x 28 24 x 20 5 x 26 5 24 x 20 5 x 26 5 20 x205 x265 X
17. the beautiful Black Hills of South Dakota Matt Olson General Manager RAMVAC Dental Products Inc 800 5 RAMVAC 800 572 6822 Safety and Regulatory Information CustomAits ramvac Compressors meet the most current and highest safety standards CustomAin sa wac Compressors are UL 60601 classified comply with NFPA 99C Level 3 gas system requirements and are manufactured in a FDA Registered ISO 9001 2000 and ISO 13485 2003 certified facility Here s what you need to do to ensure the safety potential of this equipment is achieved Make sure your equipment is installed according to our written instructions and the Installation Checklist is completed If you have purchased your CustomAir compressor from an authorized dealer the dealer is responsible for presenting you with the completed checklist Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Type of protection against electrical shock Class 1 Degree of protection against elecrical shock Type B The C1 Control is designated IPX0 and must be protected from ingress of water The C1 Control label includes safety symbols with special meanings This means there is more This stands for a Type B Applied Part information available in this which means the equipment is approved for User Guide patient contact Inside Front Cover SOF_7 5 1 07 04 Effective date 02 Ju
18. tions WARNING Property damage and or personal injury may result if directions are not followed or OEM parts are not used CAUTION Connect only equipment suitable for listed maximum pressure of the compressor SOF_7 5 1 07 04 lf vital equipment is used an alternative air source should be available in case of equipment failure Page 3 Effective date 02 Jul 08 User Guide IMPORTANT FEATURES CustomAlr eanvac Custom Air aac Important Features Intake filter Compressor Heads a SIN Er IL _ Particulate Filter a oe x r 7 Ir r z a a Safety valve ek 2 i aa in j E Isolator Mounts 4 per motor Tank Moisture me Indicator Lift Handle Loops Heat Exchanger and Fan Shut off Valve to facility plumbing C1 Control Ie E es PERRE E kr Filter Indicator ot NN n Filter Drain Fittin Jm 9 Coalescing Filter Model 1025D is pictured Other models have identical features with the exception of model 1029T which has a motor control box on the left end Page 4 SOF_7 5 1 07 04 Effective date 02 Jul 08 CustomAir ramvac OPERATION User Guide Theory of Operation When power is applied fresh air is taken in through air filters and compressed by the pump pistons The compressed air is very warm and is cooled for use by the heat exchanger and fan Air is then delivered to coalescing filter to remove most of the moisture The coalesc ing filter is equipped with a automatic d
19. to place Plug power cord into outlet Return compressor to service Replacing Particulate Filter Note All models use the same particulate filter 1 w N e 0 AT Oy n Turn compressor off with the power button on the C1 Control Unplug compressor from outlet Bleed air from system Push up slightly and turn particulate filter bowl slightly and remove Remove filter by turning completely out Install new 01 micron filter Position filter bowl push up slightly and turn into place Plug power cord into outlet Return compressor to service SOF_7 5 1 07 04 Effective date 02 Jul 08 MAINTENANCE Intake Filter Cap Turn to remove Intake Filter 1 on each head Coalescing Filter Element User Guide Intake Filter Element Fresh air Intake Filter Indicator Coalescing Filter Bowl Filter Drain Page 9 User Guide MAINTENANCE CustomAir s ramvac Inspect Dryer 1 Operate the compressor until the pressure of the tank reaches at least 45 psi 2 Turn the compressor off with the Power button on the C1 Control 3 Carefully open the tank petcock 4 If no water drains from the tank when the valve is opened the dryer is working and go to step 6 5 If water drains from the tank when the valve is opened the dryer is not working See Dryer Service Procedure on web at www ramvac com or contact RAMVAC at 1 800 572 6822 6 Return compressor to service C1 Control Tes
20. we TIN for Air Leaks 1st Week and E rm cc cc gg Replace Intake Filters Intake Filters aly Replace annually or when filter indicator moves Replace Coalescing Filter to completely red when unit is running Replace annually or when filter indicator moves to completely red when unit is running Inspect Dryer Annually Test Safety Valves Annually Replace Dessicant Cartridges Every 5 years Replace Particulate Filter To reset maintenance light press and hold Motor 1 Disable and Motor 2 Disable buttons at the same time until amber lights blink once Page 8 SOF_7 5 1 07 04 Effective date 02 Jul 08 CustomAir ramvac Replacing Intake Filter Note All models use the same intake filter 1 for each head NE et ad pa a Turn compressor off with the power button on the C1 Control Unplug compressor from outlet Remove intake filter cap by pressing down and rotating Remove intake filter and discard Install replacement filter and filter cap Plug power cord into outlet Return compressor to service Replacing Coalescing Filter Note All models use the same coalescing filter if Pe ON oO co 7 O gt En Turn compressor off with the power button on the C1 Control Unplug compressor from outlet Bleed air from system Push up slightly and turn coalescing filter bowl slightly and remove Remove filter by turning completely out Install new 5 micron filter Position filter bowl push up slightly and turn in
Download Pdf Manuals
Related Search
Related Contents
行える Emerson Fisher easy-e EZ Data Sheet Escape™ Series Instruction Sheet Hoja de instrucciones VSP 526 User Manual V1.0 Attwood 69212T User's Manual Copyright © All rights reserved.
Failed to retrieve file