Clean Air Box Series Calibration Kit User Manual www.bullard.com
Contents
1. aSullard Clean Air Box Series Calibration Kit User Manual Kit includes Kit CO Cylinder Zero Air Hardware CABCK17L 17L 10 ppm 17L Regulator CABCG1017L CABCG017L tubing fitting CABCK 34L 10 ppm 34L Regulator CABCG10 CABCGO tubing fitting carrying case CABCK103L 103L 10 ppm 103L Regulator CABCG10103L CABCG0103L tubing fitting carrying case A WARNING Bullard recommends using impurity free test gas to perform Zero adjustment Bullard Zero air CABCGO Failure to observe this recommendation may cause premature failure of the sensor A WARNING Use only 10 ppm CO gas for calibration Using a higher concentration may produce an inaccurate calibration and may damage the sensor Bullard CO gas CABCG10 Zero Point Adjustment 1 Connect compressed air source to CAB or COHP 2 Allow air to pressurize system for 5 10 minutes 3 Perform zero point adjustment and calibration NOTE Tf the unit is experiencing a temperature change of more than 20 degrees wait 15 30 minutes before beginning calibration sequence Zero calibration should be performed before calibrating the monitor with CO gas Use impurity free test gas Zero Adjustment Procedure 1 Remove the front cover of the CO Monitor 2 Push the ON button The unit will beep and begin a 60 second countdown 3 Rotate the knob located on the front of the CO Monitor to the CAL position 4 AC will appear on the display 5 Pre
2. under warranty with all transportation charges pre paid Bullard cannot accept returned goods ona freight collect basis 5 Returned products will be inspected upon return to the Bullard facility Bullard Customer Service will telephone you with a quote for required repair work which is not covered by warranty If the cost of repairs exceeds stated quote by more than 20 your coordinator will call you for authorization to complete repairs After repairs are completed and the goods have been returned to you Bullard will invoice you for actual work performed ISO 9001 certified 2008 Bullard All rights reserved 6081257980A 0808
3. 42 999980 Fax 49 2642 9999829 www bullardextrem com Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5 www bullard com Return Authorization The following steps must be completed before Bullard will accept any returned goods Please read carefully Follow the steps outlined below to return goods to Bullard for repair or replacement under warranty or for paid repairs 1 Contact Bullard Customer Service by telephone or in writing at Bullard 1898 Safety Way Cynthiana KY 41031 9303 Toll Free 877 BULLARD 285 5273 Phone 859 234 6611 In your correspondence or conversation with Customer Service describe the problem as completely as possible For your convenience the representative will try to help you correct the problem over the phone 2 Verify with your representative that the product should be returned to Bullard Customer Service will provide you with written permission and a return authorization number as well as the labels you will need to return the product 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or regulations prohibit the shipment of hazardous or contaminated materials Products suspected to be contaminated will be professionally discarded at the customer s expense 4 Ship returned products including those
4. e calibration gas cylinder 10 ppm CO required Insert the calibration connector fitting into the center of the knob Open the cylinder valve fully The flow rate is preset and there is no need to adjust it The Red LED on the front of the monitor will continue to blink for approximately 90 seconds during which the calibration process will take place aSullard Watch for the green LED to blink This indicates a successful calibration Verify by turning knob to TEST LCD display should alternate between CO and 10 1 If this does not occur wait 5 minutes and repeat calibration Close the regulator on CO gas cylinder completely and remove the calibration connector fitting from the center of the knob Rotate the knob to the RUN position NOTE Knob must be in RUN position for active monitoring of CO in the air supply The monitor is now calibrated and should be recalibrated monthly or ona schedule with local requirements NOTE Typical calibration takes approximately 90 seconds If unit will not calibrate within 3 minutes repeat the calibration steps with compressed air turned off If the problem persists contact the Bullard Customer Service Department at 1 877 BULLARD Americas E D Bullard Company 1898 Safety Way Cynthiana KY 41031 9303 Toll free 877 BULLARD 285 5273 Tel 859 234 6616 Fax 859 234 8987 www bullard com Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 26
5. ss and hold the On Off button until it beeps 6 AO will now appear on the display 7 Attach the regulator to the zero gas cylinder 8 Insert the calibration connector fitting into the center of the knob on the front of the monitor 9 Open the cylinder valve fully The flow rate is preset so there is no need to adjust it 10 The red LED will continue to blink for approximately 90 seconds during which the zero adjustment process will take place 11 Watch for the green LED to begin blinking This indicates a successful zero 12 Verify by turning knob to TEST LCD display should alternate between CO and O or 1 If this does not occur wait 5 minutes and re zero 13 Close the regulator on zero gas cylinder completely Remove the calibration connector fitting from the center of the knob NOTE Knob must be in RUN position for active monitoring of CO in the air supply 14 With the incoming air flowing turn the knob to RUN Calibration Instructions Monitor calibration should be performed monthly or whenever the reading may be questionable A calibration schedule should be maintained for future reference To obtain an accurate calibration we recommend the use of Bullard calibration kits Calibration Procedure Calibration is recommended only after a zero so the unit will already be on Rotate the knob located on the front of the monitor to the CAL position AC will appear on the display Attach the regulator to th