Home

UC-350E+ Encoder User`s Manual

image

Contents

1. 3 2 1 1 8 Maximum and Minimum Bit Rate Setting These sub menus will allow users to configure the variable encoding video bitrate range These menus will only have an effect on the Encoder output bitrate if unit is configured for VBR Variable Bitrate encoding e UC 350E Encoder User s Manual 1 1 1 8 MaxBitrate 019 000Mbps 1 1 1 C MinBitrate 000 500Mbps 3 2 1 2 Audio Setting This sub menu will allow users to configure the audio encoding parameters 1 1 2 1 Input 1 1 2 2 Sampling 1 1 2 3 Audio 1 1 1 2 4 Audio 2 3 2 1 2 1 Audio Input Setting This sub menu will allow the user to choose which input will be used as an audio source The options are RCA XLR amp SD SDI Embedded audio 1 1 2 1 Input RCA XLR SD SDI 3 2 1 2 2 Sample Frequency Setting This sub menu will allow the user to choose their audio sampling frequency The available choices are 48KHz 44 1Khz 32Khz 1 1 2 2 Sampling 48 K Hz 44 1K Hz 3 2 1 2 3 Audio 1 Setting This sub menu will allow the user to configure the individual parameters for Audio 1 Channel encoding Available configurations are Audio Bitrate Audio Delay amp Audio Coding Type These changes will only affect Audio1 encoding e UC 350E Encoder User s Manual 1 1 2 2 1 Bitrate 1 1 2 2 2 Coding Type 1 1 2 2 3 Delay 3 2 1 2 3 1 Audio Bit rate Setting This sub me 1 1 2 3 1 Bit rate 01 03 64 K bps 96 K bps 112 K bps 128 K bps 1
2. CH2 Program Count Y Program 1 DTV2 Select Program gt Cancel Program Modify Program Refresh Input Refresh Output J Equipment Name IPAddress fall Equipment Type TEE Errornfomations nen RA PER a en ne RES em CANA User can choose any program of the output channels and then click _Mediy Progam HE button to pop up the program modify interface After modification user can click to confirm System will automatically refresh new output programming a Edit Program Info Prograrn DVI Program Num 101 PMT PID x 100 PCR PID x 101 ECM1 PID Ox ECM2 PID 0x type x1B AudioPid Cancel 39 x NH NE EEUU Amp Am ER e WU HU UL EVA Technologies Inc 4 3 7 7 Real time Monitoring of Output Stream The current total output stream and the number of output programs will be displayed on this table for live monitoring Remote Load Remote Save BA Factory Setting IN Restan GJ LocalSave Local Load freq UCISE Encoder Program Control Realtime Monitor PID Filter Table PID Pass NIT Parameters Realtime Monitor 1 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 m Name M Info Errorlin cemationss C SystemTime CyEqupmert Type UC 350E Encoder TIP Address 192 168 000 136 CC3NMS Version NMS 584 CjHardWare Version 1 0 CIS ae Version 0 07 VersionDate 20120425 User Name adein User s Authority Ad
3. Authority Main Aste Register ne To begin add a Frequency Point This can be done by clicking Add Freq Point within the Edit drop down menu AddFregPoint FregPointN ame Fregi Ok X Cancel Alternatively users can right click on an empty section of the left hand side column to pop up a short cut menu and selecting Add Main Freq Point 25 Y Network Management System file Edit Operate Setting Help d lt Freq Port Em lt E Add Equipment DR Modify Property m Delete 4 2 4 Adding Equipment under a given Frequency Point When a Freq Point is selected users can add equipment by right clicking then selecting Add Equipment within the Edit drop down menu Tile Qperate Setting Help TE AddfregPoant Corbet 4 duis YH LocalLosd f lt Fesa Port Dh Edit Equipment Cirle X Delete Pauigpeseet Curl G 8121 Cur 4H Gu Name Into Equipment Name 5 Padjen Bel Equpmert Tye O Enotr cmaions Sytenlme CE gupmernt Type CMP Adde Veron Card we Vernon C Saffw we Vernon lt gt Veer ane ekhia Tier s Aatherity Akin hate Register no 26 as e Jun WU LEVE Technologies Inc UC 350E Encoder User s Manual 4 2 5 Edit Equipment Interface Edit Equipment IP Address 192 168 000 136 Port 2007 Equipment Name LC 350E Encoder Equipment Type UJ C 350E Encoder El Jf OK X Cancel Users shoul
4. 1 2 3 1 Bitrate 02 03 160 K bps 192 K bps 224 K bps 256 K bps 1 1 2 3 1 Bitrate 320 K bps 384 K bps 3 2 1 2 3 2 Coding Type Setting This sub menu will allow the user to select Audio1 s encoding format 1 1 2 3 2 Coding Type 01 03 MPEG 1 L ayer II DD CE AC3 CE 1 1 2 3 2 Coding Type DD PE AC3 PE 1 1 2 3 2 Coding Type HE AAC 3 2 1 2 3 3 Delay Setting This sub menu will allow the user to add a delay to the Encoder s audio output This feature is intended to facilitate proper Video Audio sync Adjusting the delay value is not 16 mm m NEU amp n ER e DNS UL EVA Technologies Inc necessary if the incoming video and audio being fed into the Encoder is already in proper sync 1 1 2 4 Delay 0000ms 3 2 1 2 4 Audio 2 Setting Audio2 configuration is identical to Audio1 configuration Please refer to the previous sections regarding Audio 3 2 1 3 System Setting This sub menu will allow the user to set system parameters 1 1 3 1 Prog Number 1 1 3 2 Video PID 1 1 3 3 Audio 1 PID 1 1 3 4 Audio 2 PID 1 1 3 5 PMT PID 1 1 3 6 PCR PID 1 1 3 7 IP Enable 1 1 3 8 Out addres 1 1 3 9 Out Port 3 2 1 3 1 Program Number Setting This sub menu will allow the user to set the program number 1 1 3 1 Prog Number 0X 0301 3 2 1 3 2 Video Audio PMT PCR PID Setting This sub menu will allow the user to set relevant PIDs The maximum value cannot exceed Ox fff e UC 350E Encoder Use
5. 60Hz or AC 240V 10 50 60Hz Requirements Power 17 6W Consumption O wu e Uo NE T NH Nm EEUU Amp Am ER e Jun 4G UL EVA Technologies Inc e UC 350E Encoder User s Manual 1 4 Inner Architecture CVBS or SD SDI One Video ASI Output XLR RCA SDI Two Stereo Audio ASI IP Output and Encoder IP Output Or ASI with Encoder IP Output ASI 1 5 Appearance and Description Front Panel Illustration 2 90 LCD Window I2 Left Right Up Down Button Enter key 2 3 Menu Key 5 MemuKey S 5 bockKey EE 6 LED indicators 1 3 3 3 3 3 3 3 3 3 3 LED Indicators Rear Panel Illustration ASUIN AC 100V 240V 50 60Hz 2A ASI out2 Oi Q oL J Reset mm m cvas RCA Il RCA2 OOO I Crd 2 XLR input SD SDI input 1 3 1 CVBS input UC 350E Encoder User s Manual e easio o 8 NMS Network Management port IP Output port ASI Input interface Power Switch and Power socket Grounding Pole Chapter 2 Installation Guide 2 1 Packaging Check When users first open the device packaging it is advised to check items according to the packing list It normally includes the following items UC 350E Encoder XLR interface input cable Analog Audio Video Composite Input Cable ASI Cable Power Cord If any item is missing from the list please contact your local dealer 2 2 Installatio
6. NIT Network Information Table 4 3 7 10 1 NIT Parameters User can set the network ID and network name in the field Network ID This describes the output TS Network ID Network Name This parameter describes the output TS s network name Private Descriptor This checkbox will allow user to insert the private descriptor into the output TS The private descriptor includes two parts one is a descriptor tag and the other is the descriptor information Descriptor tag The descriptor tag is an 8 bit field which identifies each descriptor 4 3 7 10 2 Editing NIT table After checking the checkbox the NIT editing menu is active The will also insert the EIT table into the output TS 43 UC 350E Encoder User s Manual 4 3 7 10 3 Read and Save These two buttons will trigger a window to load save the current NIT table file from to a file on local computer hard disk 4 3 7 10 4 Add There are 2 Add buttons on the editing toolbar The upper one is for DVB C network By pressing the Add button user will trigger an editing window from which they can set the corresponding parameters in the trigged checkbox NIT Operation The next Add button is for DVB S networks It will also trigger an editing window after clicking NIT Operation OPSK linear horizontal Y X Cancel 44 mm m NEU amp n ER e DNS UL EVA Technologies Inc e UC 350E Encoder User s Manual 4 3 7 10 5 Modify The modify butto
7. is not to be confused with sub menu 3 2 1 3 3 that would only broadcast the encoded video e UC 350E Encoder User s Manual 3 1 Ip Out Enable YES 3 2 3 2 IP out Address Setting When IP output mode has been set to ENCODER user can enter IP output interface address If the output mode has been set to MPTS then configuration in this field will have no effect 3 2 p Out Address 224 002 002 002 3 2 3 3 IP output Port Number Setting This sub menu will allow the user to select the TSIP output port Unit output must be set to Encoder sub menu 3 2 3 6 rather than MPTS for this function to work 3 3 p Out Port 02001 3 2 3 4 Trans Stream ID Setting This sub menu will allow the user to select the Trans Stream ID 3 4 Trans Stream ID 00000 3 2 3 5 Output Stream This sub menu will allow the user to set the total aggregate Output Stream Bitrate This value should be big enough to contain Video Audio and Overhead data 3 5 Output Stream 040 000M bps 20 mm m NEU amp n ER e DNS UL EVA Technologies Inc e UC 350E Encoder User s Manual 3 2 3 6 Output Mode Setting This sub menu will allow the user to select between MPTS and Encoder output modes Selecting Encoder SPTS means the outgoing stream will only have one program 3 6 Output Mode 01 01 MPTS Encoder 3 2 3 7 ASI Output Setting This sub menu will allow the user to select the ASI Output
8. 4 3 1 Encoding Part Setting 29 mH m NEU amp n ER e Jn U UJE Technologies Inc e Remote Load Remote Save EA Factory Setting fL Restat LocalSave fi Local Losd lt heal lt UC 350E Encoder UC 350 Encoder Encoder Part Multiplex Part Encode Channel General Parameters Video Parameters Audo Parameters Audo Parameters2 System Parameters Advanced Parameters Video Standard Bitrate Mode ENC Standard awe x ea coa CHE cua A Ratio PESA Y MacVideo Birate 3X0 ppp Min Video Birate 500 kbps Videob rate 000 kbs Brightness 0 isi gt 255 128 Contrast 0 El 255 128 Saturation Ol4 ml 55 128 Hue 0 mi gt 255 127 IP Address fal Equipment Type TT Enodntomations UINMS Version NMS 584 C3Hardware Version 1 0 Cy Sotware Version 0 07 User Name admin User s Authority Admin Auto Register Tes VersionlDate 20120425 4 3 1 1 Video Standard Setting In this interface users can set the video standard There are two options NTSC and PAL Users can select different video formats through the pull down list 4 3 1 2 Bit Rate Mode This interface will allow the user to select between CBR and VBR encoding Users can refer to chapter 3 for additional information 4 3 1 3 Encoding Standard Setting There are three encoding formats from which users can select according to their needs MPEG 2 MPEG 4 and H 264 4 3 1 4 Display Width 30 n
9. 90 Short term 86 105KPa Install rubber strips for sealing door gaps and dual pane glasses for windows Please ensure wallpapers or paint do not release particles into the datacenter airflow Fire alarm system and extinguishers Ensure device power source air conditioning power source and lighting power sources are independent circuits Device power supply requires AC power at 240V 50Hz Please check carefully for power line problems before powering on the equipment ne e Jun WU LEVE Technologies Inc UC 350E Encoder User s Manual 2 2 3 Grounding Requirement Good grounding practices will ensure the proper function and long term reliability of the device This will provide protection from power surges and interference It is imperative the unit is used only when properly grounded Coaxial cable s outer conductor and isolation layers should keep proper electric conduction with the device s metal housing Grounding wires must contain copper conductors in order to reduce high frequency impedance The grounding wire must also be as thick and as short as possible Users should make sure the two terminations of their grounding cables are properly secured Current pass through should be tested Anti rust should be applied on all relevant connections Do not include any other devices in this unit s grounding circuit The minimum contact patch area between the grounding wire and the device s frame should be no less than 25m
10. Auto Register No P 4 2 7 Save Configuration Once satisfied with configured settings users can commit the changes to memory by EJ Remote Save clicking the button on the toolbar Previous settings can be reloaded from memory by clicking the button Users can also save and load setting configurations to their computer s hard drive e Local Save Clicking the button will pop up a Save File dialog box which will allow users to choose their configuration file destination 28 UC 350E Encoder User s Manual SaveFile ED 7 eme 95620 cS fee2 f6ch91T2chd89b4 al c2c 5 back O cor el dr aw9 me Files of type bin z Cancel B Local Load oimilarly users can click the button to popup the Read File dialog box User can then choose which configuration file to load unto the device LY My Documents er My Comp e M Net Fie pame Open Files of type txt X Cancel 4 3 UC 350E Encoder Operation Selecting the UC 350E will display the device s configuration in the right hand side operations panel The interface is mainly composed of encoding video parameters audio parameters and the encoding system parameters etc Confirm Activates changes to configured parameters Note If the Remote Save button is not clicked the device will lose current parameters after rebooting the device Get Reads the device current settings and displays them in the operations panel
11. GP un Epa T S ed Technologies Inc NMS Version 5 0 20 SW 0 07F HW 1 0 UC 350E Encoder User s Manual Date 2014 04 23 Version 1 4 DIRECTORY CHAPTER 1 PRODUCT OUTLINE u een 1 LICOUTLINE a 1 12 FEATURES a 1 L3 SPECIBICATIONS Gr 1 LA INNER PRINCIPLE sie 3 1 5 APPEARANCE AND DESCRIPTION u a en eee nie nes et 3 CHAPTER 2 INSTALLATION GUIDE nu 4 ZI ACOUISITION CHECK ce 4 2 2 INSTALLATION PREPARATION cn en 4 2 9 WIRE CONNECTIONS nk 6 Z4 SIGNAL CABLE CONNECTION ek 7 CHAPTER S OPERATION u nee 10 3 LINITIALTZING a 10 32 GENERAL SE T TING ae 11 CHAPTER 4A NMS SETTING airis sii 23 41 INSTALLA TION is 23 4 2 SOFTWARE OPERATION Ss en 23 4 3 UC 350E MPEG 2 H 264 SD ENCODER OPERATION mme 29 CHAPTER 5 TROUBLESHOOTING zz ee en 45 CHAP TER OS PACKING LIST aus 46 e UC 350E Encoder User s Manual Chapter 1 Product Outline 1 1 Outline The UC 350E Encoder is Upcom Technology s newest professional SD Video amp Audio encoding and multiplexing device with full functionality lt has one video along with two simultaneous audio encoders which support MPEG 2 and H 264 encoding types Furthermore it can support MPEG 1 Audio layer Il LC ACC HE AAC V2 and can support ultra low video bit rate 0 25 15Mbps for H 264 encoding and 0 5 15Mbps for MPEG 2 encoding Moreover it has one ASI input interface and can multiplex the encoder channels while giving ASI IP output simultaneously 1 2 Features Suppor
12. M A 00 139M A 00 183M 3 2 General Settings After pressing the Lock key to unlock device and enter the main menu the LCD will display the following options 1 Encoder Setting 2 ASI Setting 3 Output S etting 4 Network S etting 5 Saving Config 6 Loading Config 7 Version The gt icon represents the current selection Users can press the ENTER key to navigate into the specified submenu in order to modify the device s parameters 3 2 1 Encoder Settings This menu contains the general settings pertaining to Video and Audio encoding Select Encoder 1 to configure it s parameters 1 1 Encoder 1 3 2 1 1 Video Settings The Video Settings menu has the following sub menus e UC 350E Encoder User s Manual 1 1 1 Video 1 1 2 Audio 1 1 3 System 1 1 4 PG Muxer 3 2 1 1 1 Video Input Setting This sub menu will allow the user to choose the encoded video format The top right of the LCD screen will show the current and total number of pages Input Format PAL B G H D Input Format PAL M Input Format NTSC J Input Format NTSC 4 43 3 2 1 1 2 Video Brightness Contrast Saturation Hue Setting User can adjust video Brightness Contrast Saturation and Hue settings in this sub menu The adjustable range is 0 255 The value found outside the parenthesis is a decimal while the inside value is hexadecimal 1 1 1 2 Brightness 128 0x80 1 1 1 3 Contrast 128 0x80 1 1 1 4 Saturati
13. ain Auto Register Yes 4 3 7 7 1 Current Program Number This field indicates the number of the programs in the output TS 4 3 7 7 2 Current Bit rate This field indicates the output TS s real time effective bit rate 4 3 7 7 3 Maximum Bit rate This field indicates the maximum bit rate that the output TS s real time effective bit rate ever reached 40 4 3 7 8 PID Filter Table z Encoder Part Multiplex Part Program Control Realtime Monitor PID Filter Table PID Pass NIT Parameters PID Filter T able PMT 0x0300 Setting Unselect all Refresh Gets the PID filter table from the device Setting Submits the PID filter table to the device Unselect All Clears all selections 4 3 7 9 PID Pass Encoder Part Multiplex Part Program Control Realtime Monitor PID Filter Table PID Pass NIT Parameters Ch Number Input PID Ox Output PID Ox FER Q T i Transparent The PID pass function will allow users to pass unmodified desired PIDs which may not 41 mm m NEU amp m ER e Jn AU UL EVA Technologies Inc e UC 350E Encoder User s Manual belong to any programs This can include but is not limited to NIT tables and EPG PIDs 4 3 7 9 1 Channel Number Users can check the corresponding PID channel number in this field 4 3 7 9 2 Input PID and Output PID The Old Input PID is the PID number in the TS from given Port The corresponding New output PID can be altered if r
14. allows users to set their Network ID The possible values range from O to OxFFFF 4 3 6 4 Output Address and Port Number Users can set the encoder IP output address and port number in this filed 4 3 6 5 Device Mode Users can set the Encoder IP output Mode in this field by selecting between MPTS and Encoder through the pull down list MPTS means that the output stream from the DATA port is MPTS while Encoder means that the output stream from the DATA port is SPTS 4 3 6 6 ASI Output Channel Users can set the Encoder ASI output Mode in this field by selecting between MPTS and Encoder through the pull down list MPTS means that the output stream from the DATA port is MPTS Multi Program while Encoder means that the output stream from the ASI port is SPTS Single Program 4 3 6 7 SDT Insertion y DI Insetion Enables the SDT insertion function 4 3 6 8 IP Output Enable Users can decide whether to enable the IP output function by selecting the checkbox 4 3 6 9 NIT Insertion NIT Insertion fe Enable Disable Users can decide whether to enable the NIT insertion function in this filed 4 3 6 10 PSI SI Editor This button will trigger the PSI SI Editor for some advanced users usage 36 m m mm me n ee e Jun mm WU EVE Technologies Inc e e UC 350E Encoder User s Manual 4 3 7 ASI Input Multiplexing Setting File Edit Operate Setting Help gt Remote Load Remote Save Factory Setting N Restart a Local Sav
15. bps 64Kbps C SEK bos Y O SpitemTime User Name admin User s Authority Admin Auto Register Yes VerzionDate 20120425 4 3 2 1 Audio Format Setting This field will allow users to select the encoded audio format 4 3 2 2 Sampling Rate Setting This field will allow users to select the sampling frequency Available choices are 48000Hz 44100Hz and 32000Hz 4 3 2 3 Audio Bit rate Users can set the Audio Bitrate in this field 4 3 2 4 Audio Delay This field will allow users to enter Audio delay timing This is not necessary if the video and audio being fed into the device is already in proper sync 4 3 3 Audio 2 Parameter Setting The operation of Audio parameters 2 is the same as Audio 1 32 Encoder Part Multiplex Part Encode Channel General Parameters Video Parameters Audio Parameters Audio Format e MPEG 1 Layer PE AC3 C CE AC3 C LCO AAC Sampling Rate e 48000Hz C 44100Hz 32000Hz UC 350E Encoder User s Manual Audio Parameters2 System Parameters Advanced Parameters C HE AAC Audio Bitrate C 32Kbps C 48Kbps C 64Kbps C 96Kbps C 112Kbps e 128Kbps C 160Kbps C 192Kbps C 224Kbps 256Kbps C 320Kbps C 384Kbps Audio delay ms Confirm 2 Equipment Name IP Address fed Equipment Type Errorlnformations QJ SystemTime 4 3 4 System Parameters In this field users can set the corresponding channel parameters such as the ou
16. ce cable is included in the device s packaging One end is connected to the signal source equipment while the other end is connected to the Encoder s XLR input interface The Encoder s XLR interface input port and its connected cable is illustrated below 2 4 2 SD SDI input cable connection Users can find the SDI interface input connector on the device s rear panel If in doubt refer to the rear panel illustration included in this manual chapter 1 5 The required SDI BNC interface cable is included in the device s packaging One end is connected to the signal source equipment while the other end is connected to the Encoder s SDI BNC input interface The Encoder s SDI interface input port and its connected BNC cable is illustrated below 2 4 3 Unbalanced Audio and CVBS Video Input Connection Users can find the CVBS and RCA interface input connectors on the device s rear panel If in doubt refer to the rear panel illustration included in this manual chapter 1 5 The required CVBS and RCA interface cable is included in the device s packaging One end is connected to the signal source equipment while the other end is connected to the Encoders CVBS and RCA input interfaces The Encoders CVBS and RCA interface input ports and its connected cables are illustrated below 2 4 4 ASI Output Interface Connection Users can find the ASI interface output connector on the device s rear panel If in doubt refer to the rear panel i
17. content 3 7 ASI Output 01 02 MPTS Encoder 3 2 4 Network Settings This sub menu will allow the user to configure the Encoder s network parameters 4 1 IP Address 192 168 000 136 4 2 Subnet Mask 255 255 255 000 4 3 Gateway 192 168 002 001 4 4 Console Address 192 168 002 211 3 2 4 1 MAC Address Setting This sub menu will allow the user to check the units Network Interface Card MAC address This value is read only and cannot be changed here 21 e UC 350E Encoder User s Manual 4 5 Console Address LL E 3 2 5 Saving Configuration This sub menu will allow the user to save the current configuration to memory 5 Saving Config YES NO 3 2 6 Loading Configuration This sub menu will allow the user to load previously saved configurations 6 1 Load Saved 6 2 Load Default 3 2 7 Version This sub menu will allow the user to check the Encoder s current Software SW and Hardware HW versions UPCOM UC 350 Encoder SW 0 07F HW 1 0 22 e UC 350E Encoder User s Manual Chapter 4 NMS Control Network Management System Profile A Network Management System centralizes digital TV equipment through a computer network A Network Management System NMS can support a variety of devices Most modern broadcasting systems are NMS capable Users will be able to remotely monitor and control the UC 350E through a NMS 4 1 Installation The NMS software can be copied onto a users hard
18. d follow the steps as below Enter the device IP Address Enter the device Port Number Default 2007 Enter the desired Equipment Name Choose the correct equipment type in the drop down list of Equipment Type by clicking the Y or click symbol to automatically determine the equipment type 4 2 6 Deleting Equipment Users can remove equipment from device chains by right clicking the intended target and selecting Delete in the pop up menu 27 8 Network Hanagement Software File Edit Operate Setting Help amp Remote Load Remote Save ES Factory Setting N Restart g Local Save g Local Load freg lt UC 350E Encoder o UC 350E Encoder Encoder Part Multiplex Part Video Parameters Audio Parameters Audio Parameters System Parameters Advanced Parameters Video Standard Bitrate Mode ENC Standard le MPEG2 C H 264 PAL BGHID e CBR VBR MPEGS Display Width Aspect Ratio ie Max Video Bitrate Kbps 720 576 501 v 43 Y Min Video Bitrate Kbps Video bitrate Kbps Brightness 04 gt 2550 Contrast olaj 1255 0 Saturation 0 1255 0 Hue D gt 255 0 Get Confirm Info El Equipment Name IP Address H Equipment Type Errorlnformations CD SystemTime CE Equipment Type UC 350E Encoder ESF Address 192 168 000 136 EINMS Version NMS 5 8 4 E HardWare Version E Software Version User Hame admin User s Authority Admin
19. drive A full installation is not required The software will create two files in its directory when running e Network management software X XXY log Log File e Info bin User configuration data 4 2 Software Operation 4 2 1 Login Interface A login interface will appear when trying to run the NMS software User Sign In ao mj UserName admin Password EE Auto Register Users can login using default credentials Username amp Password admin 23 4 2 2 Main Interface 8 Network Hanagement Software File Edit Operate Setting Help S mj N 3 LocalSave Efi Local Load gt lt Freq Point IP Address fal Equipment Type Enorinformations E3 Hardware Version E3 Software Version i v User Name admin User s Authority Admin Auto Register no P This software will allow the user to edit various parameters in the device tree for management and classification 24 HH EE ADU Am ER e GJ LU LJ EVA Technologies Inc e UC 350E Encoder User s Manual 4 2 3 Adding Frequency Point ti MB mt 17242 Local Seve g Local Lod fh aut Pin parat Ctrlt3 hz Frog Port tu E gu parent 1 X les Equgeent 143 deters ui Cure Um Name IER ve Gm _Equement Name of IP Atos fel Equpment Type E Emcstntomatiors O Syrie me CSE quement Type CYP Adder Veron CCS Haedw ae Vernon OSA we Vernon User Duna admin Vier
20. e e Jun WU LEVE This low bit rate encoder can support a various kinds of resolution and users can select the corresponding bit rate through the pull down list This interface will allow users to select encoding resolution and BitRate 4 3 1 5 Aspect Ratio This interface will allow users to select between 4 3 and 16 9 widescreen aspect ratios 4 3 1 6 Max Min Video Bit rate When the device is set to VBR encoding users should specify the allowable Bitrate range 4 3 1 7 Video Bit rate Setting In this field users can set the video Bitrate 4 3 1 8 Video Brightness Contrast Saturation and Hue Setting These sub menus will allow users to adjust video parameters The allowable range is 0 255 The values outside the parentheses is decimal while the inside value is hexadecimal 4 3 2 Audio 1 Parameter Setting In this field users can set the corresponding input audio parameters such as the format sampling rate Bitrate and delay time 31 x mm m EEUU amp n ER e Jn U UJE Technologies Inc Remote Loader Remote Save PR Factory Setting N Restat GJ LocalSave f Local Load heq LC 350E Encoder UC 350 Encoder Encoder Pat Mukipien Pas Encode Channel General Parameters Video Parameters Audio Parameters Audio Parameters2 System Parameters Advanced Parameters Audo Format Audo delay C MPEG Layer PEACI C HE AAC 0 E C CE AC3 le LC AAC Sampling Rate Audio Bitrate eC 32K bos G 4 2 42K
21. e g Local Load freq UC 350E Encoder UC 350 Encoder Encoder Part Multiplex Past Program Control Realtime Monitor PID Fiter Table PID Pass NIT Parameters imm Input Program Information im Output gt Encode Timeout sec gt Encode gt ASI 60 gt ASI Select Program gt Cancel Program Modify Program Retresh Input Refresh Output I Name Into m Equipment Name IP Address el Equipment Type T Errodnformations CQ SystemTime CJEqupment Type UC 350E Encoder CIP Address 192 168 000 136 CINMS Version NMS 5 8 4 3Softw are Version 0 07 The programs in the left column represent all input programs while the programs in the right column represent the output programs The Encode program section represents the 1 encoded channel The ASI program section contains the ASI input programming User can parse the programs from both sources and multiplex those programs for combined output Moreover user can modify the output programs Program Name PMT PCR video and audio PIDs 4 3 7 1 Select Program Users can select an incoming program from the ASI input port and click the Select Program button to include it in the multiplexed ASI IP output 4 3 7 2 Cancel Program User can delete the selected program from the output TS 4 3 7 3 Modify Program User can trigger a window to modify the program s properties and attributes such a
22. efault settings or customize the configuration to suit their individual needs This chapter will cover unit configuration and operation Keyboard Function Description MENU Canceling presently entered value resuming previous setting Return to previous menu ENTER Activating the parameters that need modification or confirming the change after modification LEFT RIGHT Menu navigation UP DOWN Menu navigation LOCK Lock the screen cancel the lock state After pressing lock key the system will question the user whether to save present settings to memory If not the LCD will display the current configuration state At the Resume Factory Settings submenu users can press ENTER key to confirm a return to factory settings This will erase all current settings 3 1 Initializing Once the unit is powered on it will first test whether it has an input signal source If a correct signal source is detected the device will begin encoding immediately The LCD will display the following message e UC 350E Encoder User s Manual Once the unit has finished booting the LCD will display the configured unit name and the real time bit rate in the first row The second row will show real time bit rate and stream details PAL encoding will be labeled P while NTSC encoding will be labeled N Video bitrate will be labeled V while audio bitrate s will be labeled A XXX MPEG2 H 264 Encoder 01 476 Mbps P 01 197M V 01 112
23. equired 4 3 7 9 3 Add Users can add the transparent pass PID into the PID Pass by clicking this button 4 3 7 9 4 Delete X Delete User can click the selected PID and then click delete button to delete a transparent pass PID from the PID Pass list 4 3 7 9 5 Modify Modify User can click the selected PID and then click modify button to modify a transparent pass PID s information in the PID Pass list 4 3 7 9 6 Clear Clear Users can empty the PID Pass list 4 3 7 9 7 Get Ol Get Users can read the PID Pass list from device 4 3 7 9 9 Transparent Transparent Users can turn the corresponding PID information transparent in the output TS stream 4 3 7 10 NIT Table 42 Remote Load Remote Save EA Factory Setting SL Resat GJ LocalSave fi LocalLosd LC 3S0E Encoder UC 350E Encoder Encoder Part Multiplex Part Program Control Realtime Monitor PID Fiter Table PID Pass NIT Parameters NIT Parameters Network ID 1 Network Name DTV Insert Private Description Descriptor T ag 0x Descriptor Data 0x QAM TS1D Original Network 1D 0x Frequency MHz Symbol Rate Constellation m Name MM Info Equipment Type UC 350E Encoder TIP Address 192 168 000 136 CONMS Version NMS 584 Hardware Version 10 C3SoffWare Version 0 07 User Name admin User s Authority Admin Auto Register Yes e VersionDate 20120425
24. ing output IP address and the associated port 4 3 4 9 IP Output Enable v IP Output Enable Checking the box will enable IP output 4 3 5 Advanced Parameters Setting Users can set the Mctf Length Pre Deblocking Length Acbac Enable in this interface 34 e BEE m m m n eee STechnotogis ne 9 UC 350E Encoder User s Manual Encoder Part Multiplex Part Encode Channel General Parameters Video Parameters Audio Parameters Audio Parameters System Parameters Advanced Parameters Mctf Length o e Pre Deblocking Lenath 3 el Acbac Enable e OFF C ON Get Confirm Equipment Name IPAddress fi Equipment Type Errorinfomations SystemTime 4 3 6 General Parameters Setting Encoder Part Multiplex Part Encode Channel General Parameters Output Bitrate HO Mbps Out Address 224 2 2 2 Pot 2001 Device Mode MPTS bn ox 2000 ASI Out Channel ups Original Network ID 0000 MPTS M SDT Insertion WM IP Output Enable NIT Insertion C Enable Disable PSI SI Editor Get Confirm Sl Equipment Name IP Address El Equipment Type Errorlnformations 4 3 6 1 Output Bit rate Users can set the encoder output bit rate in this filed by entering the desired value in the relevant field 4 3 6 2 TS ID This field will allow users to set their TS ID The potential value ranges from O to OxFFFF 35 ne e Jun WU LEVE 4 3 6 3 Original Network ID This field
25. llustration included in this manual chapter 1 5 The required ASI interface cable is included in the device s packaging One end is connected to the 8 Encoder while the other end is connected to the intended receiving device The Encoder s ASI interface output port and its connected cable are illustrated below 2 4 5 IP Output Interface connection User can find the Data interface network connector on the device s rear panel If in doubt refer to the rear panel illustration included in this manual chapter 1 5 A standard CAT5 or CAT6 cable is required One end is connected to the Encoder s Data port while the other end is connected to the relevant networking device The encoder s Data interface output port and its connected cable is illustrated below 2 4 6 NMS Connection User can find the NMS interface network connector on the device s rear panel If in doubt refer to the rear panel illustration included in this manual chapter 1 5 A standard CAT5 or CAT6 cable is required One end is connected to the Encoder s NMS port while the other end is connected to the relevant networking device The encoder s NMS network port and its connected cable is illustrated below e UC 350E Encoder User s Manual ASI out2 Chapter 3 Operation The UC 350E can be controlled locally through a front panel LCD screen and associated button controls or remotely through Upcom s NMS software Users can operate the equipment using factory d
26. m 2 2 4 Frame Grounding All the machine frames should be connected with protective copper strip The grounding wire should be as short as possible and avoid circling The minimum contact patch area between the grounding wire and the device s frame should be no less than 25mm 2 2 2 5 Device Grounding Connect the device s grounding point to the rack s grounding pole with copper wire 2 3 Wire s Connection The grounding wire conductive screw is located on the device s rear panel adjacent to the AC Plug connector Connecting Power Cord User should insert one end into power supply socket and the other end into device s AC power source Connecting Grounding Wire e UC 350E Encoder User s Manual If possible connect the device s grounding wire in an unshared circuit If the grounding circuit is to be shared with other devices the grounding resistance should be equal to or less than 10 Caution Before connecting a power cord to UC 350E Encoder user should first ensure the device power switch is set to OFF 2 4 Signal Cable Connections The signal cable connections consist of input and output signal cables Descriptions of the possible connection types follow below 2 4 1 XLR Interface Input Cable Connection Users can find the XLR interface input connector on the device s rear panel If in doubt refer to the rear panel illustration included in this manual chapter 1 5 The required XLR interfa
27. n Preparation When installing the device please make sure to follow all the steps listed below The installation details will be expanded throughout this chapter Users should also refer to the rear panel chart during installation The main contents of this chapter include Ensuring device was not damaged during transportation Preparing a proper environment for installation Installation of the Encoder mH m NEU amp Am e DNS UL EVA Technologies Inc e UC 350E Encoder User s Manual e Connecting the Encoder s signal cables e Connecting the communication ports if necessary 2 2 1 Device s Installation Flow Chart Illustrated as following Acquisition Fixing Check Device Connecting G rouding Wire and Power C ord Connecting S etting Running S ignal Wire Parameter Device 2 2 2 Environmental Requirements Required Dimensions Temperature Door amp Window Fire Protection Power Requirement When installing the device on an equipment rack the distance between 2 rows of equipment should be 1 2 1 5m while the distance from walls should be no less than 0 8m Electrically Isolated amp Dust Free environment required Resistivity of ground anti static material 1X10 1X10 9 Grounding current limiting resistance 1M Floor bearing should be greater than 450Kg m 5 40 Sustainable 0 45 Short term Installing an air conditioning system is strongly recommended 20 80 Sustainable 10
28. n will trigger a pop up window and allow user to modify the selected items in the NIT table 4 3 7 10 6 Delete The Delete button will remove the selected items in the NIT table 4 3 7 10 7 Clear The Clear button will remove all the items in the NIT table 4 3 7 10 8 Set the NIT table effect Users can click the Set button to take the NIT table setting into effect Chapter 5 Troubleshooting Our ISO9001 quality assurance program has been approved by the CQC All Upcom products pass testing and inspection before shipment Please follow all instructions in this manual for proper device operation Immediately Unplug the device if Power cord or socket damage occurs Any liquid flowed into the device Any dust causes a short circuit Device is present in a damp environment Device suffers from physical damage Long term idle periods are planned Maintenance is needed 45 mm m NEU amp n ER e DNS UL EVA Technologies Inc e UC 350E Encoder User s Manual Chapter 6 Packing list e UC 350E Encoder 1pcs e Audio and Video Cables 4pcs O ASI cable 1pcs e XLR interface cable 1pcs O Power cord 1pcs 46
29. on 128 0x80 e UC 350E Encoder User s Manual 1 1 1 5 Hue 127 0x7f 3 2 1 1 3 Aspect Ratio Setting This sub menu will allow the user to choose between 4 3 and 16 9 widescreen aspect ratios 1 1 1 6 AspectR atio 4 3 16 9 3 2 1 1 4 CodingType This sub menu will allow the user to choose between the supported encoding formats 1 1 1 7 CodingT ype MPEG2 MPEG4 3 2 1 1 5 Resolution Setting In this sub menu users can set the encoding resolution depending on their needs 1 1 1 8 Resolution 01 07 720 576 501 720 480 59 94l 1 1 1 8 Resolution 02 07 352 288 50 352 288 59 94 1 1 1 8 Resolution 03 07 320 240 501 320 240 59 94l 1 1 1 8 Resolution 04 07 320 180 501 320 180 59 94l e UC 350E Encoder User s Manual 1 1 1 8 Resolution 05 07 176 144 501 176 144 59 94 1 1 1 8 Resolution 06 07 160 120 501 160 120 59 94 1 1 1 8 Resolution 07 07 160 90 501 160 90 59 94 3 2 1 1 6 Video Rate Mode Setting This sub menu will allow users to choose their Video rate mode Unit can be configured for Constant Bitrate CBR or Variable Bitrate VBR The encoder will maintain a specific bitrate when set to CBR Video bitrate will vary within user set range depending on video activity if set to VBR 1 1 1 9 RateMode CBR 3 2 1 1 7 Bit rate Setting This sub menu will allow users to set their video bit rate The allowable range is 0 19Mbps 1 1 1 A Bit rate 019 000Mbps
30. r s Manual 1 1 3 2 Audio PID 0x0301 1 1 3 3 Audio1 PID 0x0302 1 1 3 4 Audio2 PID 0x0303 1 1 3 5 PMT PID 0x0300 1 1 3 6 PCR PID 0x0301 3 2 1 3 3 IP Enable This sub menu will allow the user to enable or disable the unit s IP output 1 1 3 7 IP Enable YES 3 2 1 3 4 Outgoing Address Setting This sub menu will allow the user to set the destination IP for the unit s TSIP broadcast 1 1 3 8 Out Address 224 002 002 002 3 2 1 3 5 Output Port Number Setting This sub menu will allow the user to configure the outgoing TSIP port 1 1 3 8 Out Port 1004 mm m NEU amp n ER e DNS UL EVA Technologies Inc e UC 350E Encoder User s Manual 3 2 1 4 Program Mux Setting This sub menu will allow the user to enable or disable the multiplexer 1 1 4 1 Channel Mux Y ES 3 2 2 ASI Setting This sub menu will allow the user to check the number of incoming ASI programs 2 1 Parse ASI Prog The number of available programs and how many are outgoing will then be displayed 2 1 Parse ASI Prog Prog 000 Out 000 3 2 3 Output Setting This sub menu will allow the user to configure additional Encoder output settings 3 1 Ip Out Enable 3 2 Ip Out Address 3 3 P Out Port 3 4 TransStream ID 3 5 Output Stream 3 6 Output Mode 3 7 ASI output 3 2 3 1 IP output Enable Setting This sub menu will allow the user to enable or disable Muxed Encoded program and ASI TSIP output This sub menu
31. s the 37 program name and program PID 4 3 7 4 Refresh Input Clicking this button will refresh the list of incoming ASI programming 4 3 7 5 Refresh Output Clicking this button will refresh the list of outgoing ASI programming 4 3 7 6 Multiplexing Operation Encoded programming will be multiplexed by default The V symbol means the ASI program has been multiplexed to the Output TS Encoder Part Multiplex Part Program Control Realtime Monitor PID Filter Table PID Pass NIT Parameters sm Input Program Information im Output CH1 Program Count Timeout sec gt CH1 Program Count M Program 1 DTW1 60 d Program 1 DTY1 CH2 Program Count im Prg Num 040101 MN Program 1 DTY2 am Pro Name DTV1 aa PmtPid 0x0100 am Por Pid 00101 _ Select Program im H 264 Video 0x101 dm type Ox0F 0x102 _ Cancel Program is MPEG2 Audio 0x103 gt CH2 Program Count Modify Program imm Program 1 DTV2 Refresh Input Refresh Output By default no ASI programs will be multiplexed User can select which programs to multiplex by clicking the relevant program names and then the _ Select Program gt button The selections will then be added to the output TS 38 UC 350E Encoder User s Manual Encoder Part Multiplex Part Program Control Realtime Monitor PID Filter Table PID Pass NIT Parameters gt CH1 Program Count Timeout sec w Program 1 DTY1 60
32. t H 264 MPEG2 Encoding MPEG1 Audio Layer II LC AAC HE AAC V2 Support 4 Mono Encoding Support VBR CBR Video Encoding Support Ultra Low Bit Rate Encoding Support 1xSPTS UDP IP Output Real time Output Bit Rate monitoring LCD Keyboard and NMS operation 1 3 Specifications 2 XLR input 1 SD SDI input Input 1 CVBS input 2 RCA inputs 1 ASI input BNC interface PAL 720 576 352 288 320 240 320 180 176 144 Video Resolution 160 120 160 90 50Hz mH m NEU amp Am e DNS UL EVA Technologies Inc e e UC 350E Encoder User s Manual NTSC 720 480 352 288 320 240 320 180 176 144 160 120 160 90 59 94Hz Encoding MPEG 2 H 264 0 25 15Mbps for H 264 Encoding Bit rate 0 5 15Mbps for MPEG 2 Encoding Rate Control ConstantBitRate VariableBitRate GOP Structure IBBP Advanced De interlacing noise reduction sharpening Pretreatment Encoding MPEG1 Audio Layer ll LC AAC HE AAC V2 Sampling rate 48KHz Bit rate 64Kb s 384Kb s each channel 1 ASI input multiplexed with local 1 channel TS 2 ASI outputs BNC interface Stream output SPTS over UDP 10 100Base T Ethernet interface UDP unicast multicast Audio fi m Multiplexing LCD keyboard operation NMS support Ethernet software System function upgrade English control interface 482mmx455mmx44 5mm WxDxH Approx Weight 4Kg Temperature FE 0 45 C operation 20 80 C storage Range General Power AC 100V 10 50
33. tput IP address output IP port number This sub menu will allow users to input additional channel PID information IP output address and Video Audio input interfaces Encoder Part Multiplex Part Encode Channel General Parameters Video Parameters Audio Parameters Video PID 0x Audio Parameters2 System Parameters Advanced Parameters Audiol PID Ox Audio2 PID Ox PCR PID 0 Out IP Address a PMT PID 0x 300 0302 Program Number 769 0308 Video Input Interface SD SDI y m Audio Input Interface RCA EE 224 2 2 2 Pat 1004 IP Output Enable Confirm Equipment Name 2 IPAddress fal Equipment Type EE Errorinformations 4 3 4 1 Video PID This field sets Video PID The value ranges from 0 to O x1FFF 33 mm m NEU amp n ER e DNS UL EVA Technologies Inc e UC 350E Encoder User s Manual 4 3 4 2 PMT PID This field sets PMT PID The value ranges from 0 to Ox1FFF 4 3 4 3 Audio1 amp Audio2 PID This field sets Audio PID The value ranges from 0 to O x1FFF 4 3 4 4 PCR PID This field sets PCR PID The value ranges from 0 to O x1FFF 4 3 4 5 Program Number This field sets the number of programs 4 3 4 6 Video Input Interface User can select the video input interface from the pull down list 4 3 4 7 Audio Input Interface User can select the audio input interface from the pull down list 4 3 4 8 Out IP Address Port Setting In this interface users can set the stream

Download Pdf Manuals

image

Related Search

Related Contents

事 務 連 絡 ー平成26年ー0月 3ー日    BEDIENUNGSANLEITUNG / USER MANUAL  取扱説明書 - M    Star Trac Pro Recumbent Bike User's Manual  USER MANUAL  Clique aqui  YF-TAE-0043 TIG200S&TIG200A_A0  

Copyright © All rights reserved.
Failed to retrieve file