1. ERPLAB 2 of 55 User s Manual Table of Contents 1 OVERVIEW OF TUTORIAL 5 2 GETTING STARTED 5 3 A BRIEF DESCRIPTION OF THE EXAMPLE EXPERIMENT 7 4 ADDING CHANNEL LOCATIONS YOUR DATASET 8 5 BACKGROUND CONCEPTS DATASETS ERPSETS AND BINS 11 6 CREATING AN EVENTLIST 12 7T CREATING BIN BASED EEG EPOCHS 18 8 ARTIFACT DETECTION 19 9 CREATING AVERAGED ERPS 25 10 PLOTTING AVERAGED ERP WAVEFORMS 27 11 FILTERING EEG AND ERPS 33 12 COMBINING ERP WAVEFORMS WITH BIN OPERATIONS 37 12 1 MODIFYING AN EXISTING ERPSET RECURSIVE UPDATING 37 12 2 CREATING A NEW ERPSET INDEPENDENT TRANSFORMATIONS 39 13 CREATING AND MODIFYING CHANNELS WITH CHANNEL OPERATIONS 40 13 1 CREATING A BIPOLAR VEOG CHANNEL BY UPDATING THE CURRENT DATASET 41 13 2 INSERTING A BIPOLAR VEOG CHANNEL BY CREATING A NEW DATASET 42 13 3 RE REFERENCING TO THE AVERAGE OF THE LEFT AND RIGHT EARLOBES 44 ERPLAB 3 of 55 Tutorial 13 4 RE REFERENCING TO THE AVERAGE OF ALL SCALP SITES 45 14 ASSIGNING EVENTS TO BINS WITH BINLISTER 46 15 EXPORTING AND IMPORTING EVENTLISTS TO COMBINE ARTIFACT REJECTION AND ARTIFACT CORRECTION 50 ERPLAB 4 of 55 Tutorial 1 Overview of Tutorial This tutorial takes you step by step through the analysis of a set of ERP data from an actual published experiment Luck et al 2009 Psychophysiology 46 776 786 It focuses on giving you experience with the specific steps involved in analyzing a simple prototypical ERP
2. ERPLAB TOOLBOX TUTORIAL Version Betal 1 9 1 July 2010 Tutorial written by Steve Luck Stan Huang and Javier Lopez Calderon ERPLAB Toolbox core designed by Javier Lopez Calderon and Steve Luck Important note Because this is a first release bugs are inevitable In some cases errors will occur leading to a message that instructs you to report the error to the EEGLAB developers If this happens please report the error to us at erplab erpinfo org and not to the EEGLAB developers ERPLAB has primarily been tested using EEG collected with a Biosemi ActiveTwo System along with a smaller amount of testing using EEG collected with Neuroscan and EGI systems Consequently you should be particularly careful when using this version of ERPLAB with data collected with systems other than the Biosemi ActiveTwo ERPLAB Toolbox is in a period of rapid development This version is designed to provide most basic ERP processing functions enhanced versions of these functions and additional functions will be forthcoming over the next several years Feel free to make your own modifications and additions to the toolbox and send them to us if you think they would be of value to other users Some features are present in this version that have not yet been documented and some features may have changed since this document was released In addition some of the screen shots shown in this document may reflect previous versions and may not conform with the text The
3. Figure Display Settings Help e A HE c g tn ie ci Bi Frequent Digit Bi Frequent Digit Bi Rrequent Digit E Pare Letter 4 250 500 250 500 250 500 250 500 250 500 Value caNcEL Eventiypes 58 136862 37021 ST HE The window for saving the newly created dataset is also brought up at this point The idea is that you will scan through the dataset and either save it if everything looks OK or click on CANCEL if you want to change the parameters and try again Once you have finished looking at the data click ERPLAB 21 of 55 Tutorial Ok in the window for saving the dataset if you are satisfied with the artifacts that were detected it will be named S1 EEG elist be ar Note that the scrolling EEG display window ordinarily allows you to click on an epoch that has not been marked to manually mark it or to click on an epoch that has already been marked to unmark it However this ability is disabled when you are looking at the initial results of an artifact detection procedure because the goal at this moment is to determine whether the automated procedure worked correctly Once you are satisfied and have saved the dataset you can open it again in the scrolling EEG display window and then you can manually reject and unreject epochs If at some later time you want to see how many trials have been marked for rejectio
4. VEOG ch15 ch15 label A2 15 A2 ch16 ch16 label HEOG 16 HEOG Equation List Equation Editor Mode File Users stanzsax Desktop ERP sample chanops avg earlol Clear equations Modify existing dataset recursive updating V Y I _ Create new dataset independent transformations Load list Savelist Save listas Clearfile Equation examples gt Send file rather than individual equations rp creates compact history CANCEL RUN Warn if channels will be overwritten Note that you can apply Channel Operations on either the EEG data in a dataset using ERPLAB EEG Channel Operations or the ERP data in an ERPset using ERPLAB ERP Channel Operations n most cases you will perform linear transformations of the data with these operations i e new channels are created by adding together a set of scaled old channels The order of operations does not matter for linear operations Averaging is also a linear operation Consequently performing channel operations on the EEG and then averaging will give you the same results as averaging the EEG and then performing channel operations However artifact detection rejection is a nonlinear process so it will matter whether you perform channel ERPLAB 44 of 55 Tutorial operations before or after artifact detection Whether you do it before or after will depend on what you are trying to achieve For example creating a bipolar VEOG c
5. 39 49 eoo BEI A m 2460317 0317 8 mm CO 4 lt 3 1 3948 ome Mister CANCEL APPLY As an example set up the filter as shown in the screenshot above with no high pass filter a low pass cutoff at 30 Hz a roll of of 12 dB octave a Butterworth filter type and all 16 channels being filtered Click APPLY After the filtered data have been created the standard window for saving new ERPsets will appear and you should name the new ERPset S1 30HZ you can save the ERPset to disk if desired but this is not necessary This will now be the active ERPset If you plot it with ERPLAB Plot ERP Waveforms the result will look like the following screenshots you should also plot the unfiltered data for comparison ERPLAB 34 of 55 Tutorial Figure 2 lt lt S1_ERPs_filt gt gt Measuring Click figure for larger image File Edit View Insert Tools Desktop Window Help ARTDEA BOE aD 200 200 400 600 5 5 200 200 400 600 200 200 400 600 200 200 400 600 200 200 400 600 BIN1 Frequent Category Digit BIN2 Rare Category Letter ERPLAB 35 of 55 Tutorial Now let s try filtering continuous EEG data Make S1_Chan the active Dataset loading it with File gt Load existing dataset if necessary Select ERPLAB gt Filter amp Frequency Tools gt For EEG data Set the parameters as shown i
6. 18 3 EN NEN Once the window looks like the screenshot above click RUN You can also see in the EEGLAB menu that the Channels per frame have now been updated to 17 To see the result select Plot Channel ERPLAB 41 of 55 Tutorial data scroll It should look like the screenshot below you may need to increase the plotting scale Chan Time Value biVEO 3 7871 1 2493 128 9 CANCEL Eventtypes lt lt 0 gt gt gt REJECT IUs a bit difficult to see the new channel because it is at the bottom of the window It would be nice to insert this new channel prior to the original VEOG channel rather than at the end but it is difficult to do this in recursive mode The next example shows how to do this by creating a new dataset independent transformations mode 13 2 Inserting a bipolar VEOG channel by creating a new dataset In this example we will use the independent transformations mode to create the bipolar VEOG channel and place it in the middle of the set of channels rather than at the end To get started re open the S1 Chan dataset the existing S1 Chan dataset was modified in the previous example and we want the original version Now select ERPLAB EEG Channel Operations and set it up as shown in the screenshot below Because we are creating a new dataset we need to copy any of the original channels listed as ch1 ch2 ch3 that we want to keep to the new channels listed as nch1 nch2 nch3 In this
7. 2557 Sampling rate Hz 500 EC Epoch start sec 0 000 EC Epoch end sec 2139 038 E Average reference No Channel locations Yes ICA weights No Dataset size Mb 72 3 If you now select Plot Channel data scroll and scroll ahead to the period starting at 10 seconds hit the gt gt button twice you will now see that the event code numbers that you saw before have been replaced by the event labels Scroll channel activities eegplot Figure Display Settings Help ther Corr Fesp are Lette Corr Resp Far Frequent Di Wer 7 E PES diis Merit sd Pil et T i i 12 13 Chan Time Value CANCEL Event types lt lt amp gt gt HEOC 127856 19921 69 REJECT ERPLAB 16 of 55 Tutorial The standard EEGLAB routine only provide room for about 4 characters but we have provided a slightly modified version that shows 12 characters for the event labels see the installation instructions in the ERPLAB User s Manual for instructions on installing this modified plotting function This still isn t quite enough so some ofthe labels are truncated You can modify the number of characters shown in the modified plotting function by selecting Settings Events Number of characters for event labels from within the plotting window not from the main EEGLAB window If you enter a width of 20 characters the plot will look like this Scroll channel activ
8. 400 ms This means that we are looking for a period of one voltage for gt 200 ms immediately followed by a period of a different voltage for gt 200 ms This width was chosen because fixation periods almost always last for at least 200 ms GOO _ Step Function ERPLAB 24 of 55 Tutorial After you click Accept you will see in the command window that this routine found artifacts on 12 8 of trials If you look at the scrolling data window that pops up you will see that some of the epochs with these artifacts also had blink artifacts that were detected with the peak to peak amplitude routine that was previously run with these data e g epoch 44 indicates a rejection of the HEOG channel by drawing this channel in red and the data from several other channels are also drawn in red from the peak to peak artifact detection However other epochs were rejected solely because of the step function in the HEOG channel e g epochs 208 and 209 Information about the artifacts can also be found in the EventList To see this save the EventList from the current dataset in a text file by selecting ERPLAB EventList Export EEG EventList to Text File Now open the text file in a text editor You will see something like the following item 157 158 159 160 161 162 163 164 165 166 167 bepoch ecode 79 0 80 0 81 0 82 0 83 0 84 22 9 22 9 12 9 22 9 22 9 12 label Frequent Digit Corr Resp Fre
9. and average this corrected EEG file To start you will need to load the file S1 Chan set which was created earlier Because running ICA will take a fair amount of time more or less so depending on the specifics of your computer be prepared to let it work while you go to lunch or to sleep To begin the procedure select Tools gt Run ICA Most of the default settings can be left untouched but itis important to only include channels that have the same reference electrode To do this click on channels and select all except HEOG which is a bipolar channel created between the left and right eye channels ADO Run ICA decomposition pop runica ICA algorithm to use click to select mnia J binica C iader Commandline options See help messages extended 1 Channel type s or channel indices types channels Cancel Help Ok When ICA is complete Done will be displayed in the Matlab Command Window Make sure to save this dataset by selecting File Save current dataset as and entering the filename S1 Chan ica set You will notice in the main EEGLAB window that there is now a Yes next to ICA weights Next you should plot the continuous EEG data and the ICA component time courses This can be done by selecting Plot gt Channel Data scroll and Plot gt Component Activations scroll Align the two windows to make for easy visual comparison You may wish to change the scaling of these plots i
10. be able to figure out how it works Perhaps the most useful tool is the measurement tool the icon with the small plus mark which allows you to click on the waveform and see the X and Y values time and voltage at that point on the waveform In addition this mode allows you to click on one of the panels e g the panel for the Cz electrode site which will pop up a new window showing an expanded version of that panel as shown in the screenshot below ERPLAB 29 of 55 Tutorial Figure 3 File Edit View Insert Tools Desktop Window Help DEHA hb X 9 x D EJ m I 10 8 6 2 aW M JW dV 100 2 8 200 100 0 00 300 400 500 600 700 If Include toolbar is not checked then these features are not present In this mode however the X axis is plotted at zero microvolts rather than at the bottom of each panel which is the appropriate way to plot the waveforms for publications and formal presentations Try plotting the data again with Include toolbar unchecked the result should look like the screenshot below ERPLAB 30 of 55 Tutorial ANA Figure 2 lt lt test gt gt Printing Purpose Non interactive 10 f 10 10 5 10 F 5 5 5 5 208 200800600 206 20800600 208 20090500 20 amp 20800500 10 P 10 F4 TEE FF1 5 5 5 5 208 20800500 206 2040600 208 20090600 206 20800600 10 FP 10 10 fE 10 F 5 5 5 208 2080000 206 2000600 208 2600600 20 amp 20800500 19 Pz 4p Y
11. changes you can import it back into the EEG structure We will show an example of this later in the tutorial To use ERPLAB you must create an EventList for the EEG stored in your dataset The simplest way to do this is to choose ERPLAB EventList Create EEG EventList Basic This is pretty self explanatory so we will show you how to use ERPLAB gt EventList gt Create EEG EventList Advanced The advanced version allows you to define a text label for each numeric event code or vice versa which helps to avoid the errors that often occur in experiments with many different event codes It also allows you to define the bins that you will use to sort your EEG epochs for averaging In most cases you will define your bins in a later step using something called BINLISTER but it can be done at this step if your bins are very simple You will use the advanced method for creating events if you want to create event labels from numeric event codes or if you want to assign the events to bins and you will use the basic method if you don t want event labels and you will be using BINLISTER to assign events to bins At this point EEGLAB and ERPLAB should be running and S1 EEG should be the currently active dataset you can check this in the Datasets menu You should have added the electrode coordinates to the dataset in a prior step so make sure that S1 Chan is the currently selected dataset To create the EventList for this dataset select ERPL
12. example we first copy channels 1 13 from the current dataset to the new dataset then add the bipolar VEOG as channel 14 and then copy channels 14 16 from the current dataset to channels 15 17 in the new dataset Note that the left side of each equation must indicate that we are creating channels within a new dataset e g nch1 rather than adding or modifying channels within an existing dataset e g ch1 ERPLAB 42 of 55 Tutorial 6 0 0 ERPLABBETA 1 1 814 Channel Operation GUI for EEG nch9 ch9 nch10 ch10 nch11 ch11 nch12 ch12 ONNA wr VI II NANE I m O nch13 ch13 nch14 ch14 ch8 ch9 2 label biVEOG nch15 ch14 label VEOG E nch16 ch15 label A2 nch17 ch16 label HEOG io lt mo OOo C This is a pretty long list of equations and you wouldn t want to retype it every time you want to perform this transformation To avoid retyping you can save the list of channel equations to a text file Save list and reload it later Load list You can also use a regular text editor such as the Matlab text editor to create and modify these lists of equations which can be convenient for complex transformations that contain many lines bivEOG YEOG A2 HEOG Chan Time Value Eventtypes 0 HEOG 44547 32948 1888 REJECT Once you have the window set up as shown in the screen shot above click the RUN butto
13. experiment For details of the functions used here see the ERPLAB Toolbox User s Manual 2 Getting Started We assume that you have already installed EEGLAB and ERPLAB as described in the ERPLAB Toolbox User s Manual To begin this tutorial we recommend that you start afresh with EEGLAB and ERPLAB To do this close the main EEGLAB window and type clear all and then eeglab in the Matlab command window each Matlab command should be followed with the return or enter key It is a good idea to follow this procedure when you encounter bugs or unexplained problems with EEGLAB and or ERPLAB Next you need to put the various tutorial files on your hard drive preferably in a folder named Tutorial The data from the first subject we will be processing is in a subfolder named S1 and you should make this folder the current directory in the Matlab command window At the top of the Matlab command window there is a drop down menu displaying the current directory see screenshot below Click on the browse button labeled with to the right of the current directly and choose the S1 folder The top of the window will then look something like this although the details depend on what operating system you are using MATLAB 7 4 0 R200 ra File Edit Debug Desktop Window Help 1 me di m EJ P uck Documents Software Development ERPLAB Toolbox Documentation Tutorial 51 M Next you will need to load the raw EEG data from the first subjec
14. is repeated until the end of the Test period and the largest of these peak to peak amplitudes is compared with the Voltage threshold This is an excellent way to find artifacts in which the voltage changes rapidly within a relatively short period of time e g blinks which usually peak and then subside within 200 300 ms and not be fooled by relatively slow voltage changes By default artifacts will be detected in all channels However you can specify a subset of channels to be tested in the Channel s field Hint Most windows that ask you to specify a range of values allow you to use the standard Matlab rules for numeric lists You can simply type the values separated by spaces e g 1 2 3 or you can use a colon to specify a range e g 1 3 or some combination e g 1 3 5 7 to indicate 1 3 and 5 7 ERPLAB 20 of 55 Tutorial To specify a regular set of values you can specify the first value the step size and the last value e g 1 3 Z to start with 1 and go by steps of 3 to a final value of 7 1 4 7 Finally you can specify a set of flags in the Flag field that will be set in the EventList whenever an epoch has been marked for rejection This allows you to do things like perform behavioral analyses on the information in the EventList while excluding events that contain artifacts Flag 1 is always set for events with artifacts and you can keep track of which events had which types of artifacts by setting addition
15. mode of operation the current ERPset will be directly modified After you ve updated the ERPset you can save it to a file with ERPLAB gt Save Current ERPset Once you ve created the new bin you can plot it with ERPLAB gt Plot ERP Waveforms If you select only bin 3 the result should look like the screenshot below Figure 2 lt lt S1 ERPs 30Hz diff gt gt Measuring Purpose Click on figure for larger image File Edit View Insert Tools Desktop Window Help Di hb x H EJ F4 C3 4 5 4 MA iu ww Mey i gt gt gt a PW ch 200 0 200 alas 200 0 200400600 200 0 00500 cj PLAN E Mw f Ps 0 0 Im f u sees gt u 1 200 n 200400 600 200 n 200400 600 200 n 200400600 200 n 200400600 FP2 F8 EX 5 E pwr UR DN PA AA rows AA a V 0 0 V V 5 5 5 200 L 1920400 000 200 211400600 200 n 200400600 200 n 200400 600 YEOG 42 H 5 AN P prt a yia 0 B spot E 5 sL 200400800 200 200400600 200 0 200400600 200 200400600 BINS RARE MINUS FREQUENT DIFFERENCE WAVE In this example we ve simply added a new bin to the current ERPset Note however that you can also update the existing bins in this mode In addition any changes you make in one equation can influence the results of the
16. next equation For example after creating the difference wave in bin 3 you could have an equation that uses this difference wave to create a new bin 4 12 2 Creating a new ERPset independent transformations In this example we will use ERPLAB gt ERP Bin Operations to re order the bins in the output from the previous step We will also create an additional bin that shows how to implement a somewhat more complicated transformation If you select ERPLAB gt ERP Bin Operations after performing the previous step you will see that the newly created bin bin 3 is now listed in the right panel as an existing bin see screenshot below We are going to create a new ERPset in this example so select Create new ERPset independent transformations The equations in the left panel of the window will create a new ERPset in which the first 3 bins are re ordered versions of the bins in the current ERPset and the 4 bin is the vector distance between the first two bins ERPLAB 39 of 55 Tutorial nb1 b3 This means that new bin 1 nb1 in the new ERPset will be equal to the original bin 3 b3 in the current ERPset nb2 b1 This means that new bin 2 nb1 in the new ERPset will be equal to the original bin 1 b1 in the current ERPset nb3 b2 This means that new bin 1 nb1 in the new ERPset will be equal to the original bin 2 b2 in the current ERPset nb4 sqrt b1 b1 b2 b2 This means that new bin 4 nb4 is the Pyth
17. of 55 Tutorial the ERPset menu It s usually a good idea to operate on a duplicate of an ERPset so first select ERPLAB gt Duplicate or rename current ERPset and then make a duplicate of it called S1 ERPs 30Hz as shown in the screenshot below 000 ERPLAB BETA 1 1 726 Save Erpset GUI Now select ERPLAB ERP Bin Operations The window shown below will appear AAA ERPLAB BETA 1 1 721 Bin Operation GUI b3 b2 b1 label Rare minus Frequent difference wave Equation examples The right panel lists the existing bins in your ERPset and the left panel shows a set of equations that you write to create new bins from the existing bins In the example shown here an equation is written to create a new bin 3 within the current ERPset that is equal to the existing bin 2 minus the existing bin 1 the rare minus frequent difference wave A label is also provided for the new bin You can create as many new bins as you d like in one step defining one bin on each line of the left panel You can save your bin equations in a text file by clicking Save list as and you can read in a previously saved set by clicking Load list Hint You can click on the Examples button to see examples of how to define bins ERPLAB 38 of 55 Tutorial Once you have defined the new bin as shown in the screenshot above make sure that Modify existing ERPset recursive updating is selected and then click RUN to create the new bin In this
18. through all of the events in the EventList and create a new EventList with the new bin assignments A new dataset will be created with the updated EventList If you open test txt with a text editor you will see how it assigned the stimulus events to Bin 1 or Bin 2 For example the first event code is a frequent stimulus and was therefore assigned to Bin 1 The second event code is a response and it was not assigned to any bins The third event code is a rare stimulus that was assigned to Bin 2 Note that event 73 was a frequent stimulus but it was followed by an event code 8 an incorrect response so it was not assigned to any bins If you wish you can now epoch the data perform artifact detection and create averaged ERPs for these two bins Now let s try a slightly more complicated example This time we will eliminate trials preceded by a rare stimulus whether the response to this stimulus was correct or incorrect while still requiring the current stimulus to be followed by a correct response That 15 we want to see the following sequence for a frequent stimulus frequent stimulus correct or incorrect response frequent stimulus correct response and we are time locking to the second frequent stimulus in this sequence Similarly we want to see the following sequence for a rare stimulus frequent stimulus correct or incorrect response rare stimulus correct response and this time we are time locking to the rare stimulus To implem
19. 1000 gt 9 The tilde character means not Thus in this example we are looking for a stimulus that is not followed by an 8 between 200 and 1000 ms and is followed by a 9 between 200 and 1000 ms If you would like to save the reaction times RTs associated with each trial of each type you can do this by adding rt variable name following the event codes associated with responses For example you can add this to our current example in the following manner bin 1 ERPLAB 49 of 55 Tutorial Frequent followed by correct response without incorrect response 115122 22 111 t lt 200 1000 gt 8 t lt 200 1000 gt 9 rt lt Frequent RT gt bin 2 Rare followed by correct response without incorrect response 21 112 12 121 t lt 200 1000 gt 8 t lt 200 1000 gt 9 rt lt Rare In bin 1 this will cause the amount of time between the time locking event and event code 9 to be stored to a variable named Frequent RT In bin 2 this will cause the amount of time between the time locking event and event code 9 to be stored to a variable named Rare RT These variables are stored within the bdf field of the EVENTLIST variable Three fields are used EVENTLIST bdf rtindex stores the number of variables e g 2 in this example EVENTLIST bdf rtname stores the names of the variables EVENTLIST bdf rt stores the individual RT values for each variable 15 Exporting and Importing EventLists to Combine Artifact Rejection and
20. 200 Chan Time Value CANCEL Eventypes pee P on 9199 HEOC 149 238 70088 59 m The current data file has quite a bit of high frequency noise that makes it difficult to see this small artifact which was at epoch 208 Thus the data shown in the screenshot above were first filtered with a 30 Hz low pass filter see the section on filtering for more details To get a close up view of the artifact the time window to display was set to 1 epoch and the number of channels to display was set to 3 within the Settings menu within the plotting window Without the filter the plot will look like the following screenshot ERPLAB 23 of 55 Tutorial Figure Display Settings Help E Fare Let YEOG 2 150 100 50 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 200 Chan Time Value pum pem 208 HEOG 743 8916 502088 50 maneo 2 The Step like artifacts function is well suited to detecting this type of artifact see the User s Manual for more details about this function To use it make sure that the dataset you created with the first artifact test is selected and then select ERPLAB Artifact Detection Step like artifacts Enter the parameters as shown in the screenshot below making sure that Flag 3 is selected you should have selected Flag 4 when you did the peak to peak detection and that you are detecting artifacts only in Channel 16 Note that the full width of the step function is set to
21. 7946 CLOSE lt lt lt 0 gt gt gt You can see that the large blinks in some channels of the original EEG blue traces are eliminated in the corrected EEG red traces If you are satisfied with the components you have selected click on Accept and save this new file as S1 EEG Chan icapruned set We now have the corrected dataset that we will use for the final analysis Now that the artifactual voltages produced by the blinks have been eliminated we need to mark the trials in which blinks occur during stimulus presentation so that these trials can be rejected Blinks will no longer be apparent in the corrected i e pruned file so we will use a previous version of the EEG file to determine which trials contained blinks at the time of the stimulus and export an EventList that marks those trials To do this select File Load existing dataset and open the file S1 EEG elist be which you created earlier in the epoching example Recall that in this version of the data EventList information is already stored in the EEG event structure the bins have been defined and the dataset has been epoched we need the epoched version of the dataset because ERPLAB s artifact detection routines require epoched data We will locate epochs with blinks occurring near the stimulus by selecting ERPLAB Artifact Detection Blink rejection alpha version You should enter the parameters shown in the screenshot below Because we are only concerned w
22. 9 Corr Resp 100 2040 594 00 0 0 00000000 00000000 1 133 67 22 Frequent Digit 100 9160 712 00 0 0 00000000 00000000 1 134 0 9 Corr Resp 101 7040 788 00 0 0 00000000 00000000 1 135 68 22 Frequent Digit 102 3420 638 00 0 0 00000000 10000001 1 136 0 9 Corr Resp 103 2960 953 99 0 0 00000000 00000000 1 The final step is to import this EventList into the ICA corrected dataset so that we can be sure to exclude the trials in which blinks occurred during the stimulus when we create ERPs from this dataset To do this select File Load existing dataset and open the file S1 EEG icapruned or simply select It from the Datasets menu if itis still there Next select ERPLAB gt EventList gt Import EEG EventList from text file Choose the EventList that we just exported EventList blinkdetection txt A warning window will appear asking you to confirm that you would like to replace the EEG EVENTLIST field with this file Select Yes Finally we will need to select ERPLAB Extract Bin based Epochs as we did previously epoch from 200 to 800 ms with a pre trial baseline You could then average the data using ERPLAB Compute Averaged ERPs However some other artifacts may remain in the data e g movement artifacts Thus before averaging we will rerun the same artifact detection procedures done in the section on artifact detection Please look back to remind your self of these parameters and run both the Moving Window Peak to Peak Threshold and
23. AB gt EventList gt Create EEG EventList Advanced which will bring up the window shown here e O ERPLAB BETA 1 1 707 EVENTLIST GUI Currently edited eventcodes Event Info ee ae Current Events Event Label string max 16 char XE Delete Line Bin Info optional Bin number m Update Line Bin description Boundary events Convert boundary code boundary into numeric code 99 Export EvenList Text File For plotting and others EEGLAB functions Transfer EVENTLIST info to EEG event open list save list CLOSE APPLY ERPLAB 12 of 55 Tutorial This window allows you to create a table shown in the left portion of the window that defines a set of numeric event codes text based event labels bin numbers and bin labels for each type of event in your experiment The current version of ERPLAB requires that each event have a numeric event code If your data acquisition system uses text based labels instead of numeric codes you must define a numeric event code for each text based event label If your data acquisition system uses numeric codes you are not required to create text based labels for each code but it s a good idea You can also define a bin for all or some of your event codes along with a label for that bin We will do that in this example but it is not necessary if you will be using BINLISTER in a later step to define your bins
24. Artifact Correction In this section we will show how EEGLAB s artifact correction using Independent Component Analysis ICA can be combined with ERPLAB s artifact detection and rejection abilities This is a somewhat complicated example but it illustrates two important aspects of the EEGLAB ERPLAB combination First it shows how and why to take an EventList text file that was created in one dataset export it and then import back into another dataset Second it shows how you can use artifact correction to avoid throwing out a lot of data while still eliminating trials on which the eyes were closed when the stimulus was presented Note that before attempting this exercise you should become familiar with how to perform ICA based artifact correction in EEGLAB see the EEGLAB documentation Here we will only cover the aspects of artifact correction necessary for illustrating how to combine it with artifact rejection If you take a look at the first example of artifact detection in this tutorial you will see that 29 796 of the epochs for subject S1 were detected as containing artifacts using the Moving Window Peak to Peak function By scrolling through the data it is obvious that many of these were detected due to blinks occurring during the epoch Because the activity generated during a blink is stereotyped a single component can usually be identified and removed to eliminate the influence of the artifact However the removal of a blink co
25. But make sure you start with the original version of S1 Chan not the version that has already been updated ERPLAB 1 1 814 Channel Operation GUI for EEG ch1 ch1 avgchan 1 13 15 ch2 ch2 avgchan 1 13 15 ch3 ch3 avgchan 1 13 15 ch4 ch4 avgchan 1 13 15 ch5 ch5 avgchan 1 13 15 ch6 ch6 avgchan 1 13 15 ch7 ch7 avgchan 1 13 15 ch8 ch8 avgchan 1 13 15 ch9 ch9 avgchan 1 13 15 ch10 ch10 avgchan 1 13 15 ch11 ch11 avgchan 1 13 15 ch12 ch12 avgchan 1 13 15 ch13 ch13 ch15 ch15 avgchan 1 13 15 Users stanzsax Desktop ERP sample chanops avg refere Clear equations After you click RUN each channel that is being recomputed is displayed in the MATLAB command window You can then plot the data using Plot Channel data scroll which should look like the following screenshot ERPLAB 45 of 55 Tutorial e Scroll channel activities eegplot Figure Display Settings Help A Ase w meat ws Patou be M aen rye A h tte P SAP am na an V pore Aha t d y neo a tA aie aid Ie e YU nafta F4 remm rm A aa A eA ne p onore ur mm rema pk dm I a yet wu oath hindi ie rum re rr a coll tene C 3 im T ete UP Tom e y Pm HIT rm Menag M i r Wy A rm u AWA a p aad y k _ T C4 inr nei poen eT RE RR A wr ii Aa p 3 AAA ll re at y
26. EOG ane HEOG 5 5 5 208 20800600 205 2 0 208 20 BIN1 Frequent Category Digit BIN2 Rare Category Letter There are many things you can do with the Plotting Waveform GUI For example you could plot a single column with multiple channels For example set Channels to plot to 1 4 set Row s to 4 and set Column s to 1 You will see something like this ERPLAB 31 of 55 Tutorial O Figure 2 lt lt test gt gt Measuring Purpose Click on figure for larger image File Edit View Insert Tools Desktop Window Help gt Deas AAS DEJ BOA Oo 10 F3 5 p A 0 haope Pu ABD noes 200 100 100 200 300 400 500 500 700 10 Lu Rice PT DT rel TS 0 RESORTS a 200 100 f 100 200 300 400 200 600 700 10 C3 gt a ORT ae AS 0 mr 200 100 0 100 200 300 400 500 600 700 10 C4 Bou Ss Dee 200 100 100 200 300 400 200 600 700 BIN1 Frequent Category Digit BIN2 Rare Category Letter Also try checking the Topographic checkbox to create something like the following screenshot There are w width and h height parameters that you can used to adjust the width and height of each waveform within the figure ERPLAB 32 of 55 Tutorial ANA Figure 2 lt lt test gt gt Printing Purpose Non interactive P3 A P4 11 8 6 6 200 798 11 Filtering ERPs ERPLAB contains set of filters t
27. International 10 20 System and EEGLAB can automatically determine standard coordinates on the basis of these labels These coordinates are not guaranteed to be exact but they are a reasonable approximation for simple procedures such as plotting scalp maps If you want exact electrode locations you will need to use a 3 D digitizer and measure the locations for each subject To add coordinates based on the electrode labels select Edit gt Channel locations which will bring up the window shown here Only channel labels are present currently but some of these labels have known positions Do you want to look up coordinates for these channels using the electrode file below If you have a channel location file for this dataset press cancel then use button Read location in the following qui If you do not know just press OK use BESA file for 4 shell dipfit spherical model 5 4 w Users luck Documents Software Development eeglab2008OctoberO1 _beta plug Cancel Help Ok Click Ok and you will see the window shown here Edit channel info 90p_chanedit Channel information field_name Channel label label F3 Opt head center Polar angle theta 39 947 Rotate axis Polar radius radius 0 34459 Transform axes Cartesian X X 57 5511 Cartesian Y Y 48 2004 Xyz polar amp sph Cartesian Z Z 39 BB97 Sph gt polar amp xyz Spherical horiz angle sph_theta 39 947 Po
28. Step like artifact detection procedures When the Moving Window procedure was applied to the unrejected data in the original example of artifact detection it detected artifacts in 29 796 of epochs Now only 1096 are marked because the blinks have been eliminated by the artifact correction process Those epochs in which a blink occurred near to the target stimulus will also be marked as artifacts thanks to the fact that we imported the EventList already containing these as flagged From here one can proceed as before and compute average ERPs for those trials without artifacts ERPLAB 55 of 55 Tutorial
29. To keep our example simple we will start by defining this information for only one of the trial blocks in the example experiment In this block letters were rare event code 12 and numbers were frequent event code 22 You can use the Event Info area of the window to define the event codes event labels bin numbers and bin descriptions for each event For the digits for example you can enter 22 in the Event Code number field Frequent Digit in the Event Label field 1 in the Bin number field and Frequent Category Digit in the Bin description field see screenshot below If you then click Update Line this definition will appear in the table at the left of the window You can do the same thing to define the letters event code 12 event label Rare Letter bin number 2 bin description Rare Category letters We will be computing stimulus locked averages rather than response locked averages in this example so we do not need to define bins for the response event codes However it will still be useful to define labels for the response codes so that we will not have to remember that code 9 denotes a correct response and code 8 denotes an incorrect response The table at the left of the window in the screenshot below shows how to define these events Don t forget to click Update Line after entering the information for each type of event or the information will not be added to the table Also your bin numbers must start at 1 and be con
30. aches the EVENTLIST structure that you just created to the current dataset this produces a new dataset Any operation that creates a new dataset will put up the window shown in the next screenshot which gives you some options for saving the new dataset First you need to specify a name for the new dataset This name will be stored inside the dataset and it will be shown in the Datasets menu It is not necessarily the same as the name of the file in which the dataset is stored on disk but we recommend that you use the same name for the file if you save it as a file on disk ERPLAB will automatically suggest a name for the dataset appending a string onto the end of the name of the dataset from which the new dataset was created When an EventList is generated it suggests adding elist onto the dataset name going from S1 EEG to S1 EEG elist This is not required but it is recommended otherwise you will have a hard time remembering what is in a given dataset If you check the Save it as file button and use the Browse button to select a filename the dataset will be saved to disk You can also choose to either keep the previous dataset in the Datasets menu this is the default or overwrite the previous dataset in this menu Dataset info pop newset What do you want to do with the new dataset Name it S1 EEG elist Edit description r4 Save itas file What do you want to do with the old dataset not modifi
31. agorean distance between the original bins 1 and 2 rare and frequent e n ERPLAB 1 1 814 Bin Operation GUI nb1 b3 label Rare minus Frequent difference wave Existina Bins nb2 b1 label Rare IBIN1 Frequent Category Digit nb3 b2 label Frequent BIN2 Rare Category Letter nb4 sart b1 b1 b2 b2 label Vector length Equation List Equation Editor Mode File Clear equations I Modify existing ERPset recursive updating N Create new ERPset independent transformations Loadlist Savelistas Clear file Equation examples e Send file rather than individual equations UND creates compact history CANCEL RUN Warn if bins will be overwritten After you complete your equation list you can choose to save it by clicking Save list as You will prompted to save your ERPset You can save this name as S1 ERP bo txt and just click OK Note that you can also recombine bins with different subsets of channels e g to make contra minus ipsi difference waves to isolate the lateralized readiness potential or the N2pc wave See the section on Bin Operations in the ERPLAB User s Manual for details This can be done only in the independent transformations mode Hint There is no reason to first make a duplicate of the ERPset in this mode because it always creates a new ERPset In the recursive updating mode however creating a duplicate is useful although
32. al flags for each artifact rejection test you perform For details see the ERPLAB User s Manual Once you have set all of the fields as shown in the screenshot above click Accept After scanning the active dataset for artifacts which may take some time the total percentage of trials with artifacts detected will be shown in the Matlab command window this is the total percentage marked for rejection including epochs that had been marked previously You should see that 29 796 of epochs have been marked for rejection At this point the ERPLAB artifact rejection routines automatically bring up the scrolling EEG data viewer window as shown in the screenshot below You should scroll through the data to make sure that the parameters you entered have actually caused epochs containing artifacts to be detected without accidentally marking a large number of epochs without true artifacts For example you may need to increase the threshold if epochs without real artifacts are being marked for rejection and you may need to decrease the threshold if epochs with clear artifacts are not being marked Each epoch that has been marked is shown with a yellow background and the channels within the epoch that exceeded the rejection threshold are drawn in red see screenshot below At present artifact rejection is all or none the entire epoch is discarded if an artifact is detected in one or more channels in that epoch et Scroll channel activities eegplot
33. ample when the event descriptor is 411 122 22 11118 9 121 112 12 12199 the following sequences of event codes would be successfully assigned to this bin 11 gt 8 gt 21 gt 9 22 gt 9 gt 12 gt 9 122 gt 9 gt 12 gt 9 However if the subject accidentally pressed the response button twice yielding the sequence 11 gt 8 gt 8 gt 21 gt 9 this would not match the event descriptor and this sequence would not be assigned to the bin However when a time conditioned event list other event codes can be present without disrupting the assignment of an event to a bin With the event descriptor 11 122 22 111 t lt 200 1000 gt 9 the sequence of event codes 11 21 29 would match as long as the 9 occurred 200 1000 ms after the 11 Imagine that subjects in an experiment occasionally made the incorrect response and then followed this with the correct response For example you might see the sequence 11 gt 8 gt 9 frequent stimulus followed by incorrect response followed by correct response This would still match the bin descriptor 11 122 22 111 t lt 200 1000 gt 9 as long as the 9 occurred 200 1000 ms after the stimulus To avoid this situation you can use the following bin descriptors bin 1 Frequent followed by correct response without incorrect response 113122 22 111 t lt 200 1000 gt 8 t lt 200 1000 gt 9 bin 2 Rare followed by correct response without incorrect response 2151123125121 t lt 200 1000 gt 8 t lt 200
34. change the filter settings However low pass filtering can sometimes improve artifact detection in which case you can apply the low pass filter to either the continuous or epoched EEG prior to artifact detection 12 Combining ERP Waveforms with Bin Operations The ERPLAB gt ERP Bin Operations routine allows you to create new bins by combining existing bins from the current ERPset This is most often used to create difference waves or to average across bins Bin Operations has two modes of operation see the Mode region at the bottom right in the screenshot below In one mode you use a set of equations to modify existing bins and add new bins within the current ERPset In this mode you can modify one bin and then use this modified bin to create or modify another bin this is called recursive updating In another mode the current ERPset serves as the input to a set of equations that create a new set of bins in a new ERPset this is called performing a set of independent transformations We will begin with modifying an existing ERPset which is the simplest way to simply add a few bins 12 1 Modifying an existing ERPset recursive updating As our first example we will ERPLAB ERP Bin Operations to make a difference wave in which the ERP from the frequent stimuli is subtracted from the ERP from the rare stimuli We will operate on the data in the ERPset you created earlier called S1 ERPs 30HZ so make sure it is selected in ERPLAB 37
35. contain only the data from subject S1 All subject identity information has been stripped from the data files In this experiment a letter or digit was presented every 1300 1700 ms Subjects were instructed to press a button with one hand for digits and with the other hand for letters For a given trial block either the letters or the digits were rare 2096 and the other category was frequent 80 Thus the stimulus category and the probability were counterbalanced The probability manipulation was designed to isolate the probability sensitive P3b component Different event codes were used for the digits when they were rare the digits when they were frequent the letters when they were rare and the letters when they were frequent The experiment also included a condition in which the two categories were equiprobable but that condition is not included in this tutorial The experiment was also designed to isolate the LRP by counterbalancing the stimulus category and probability with the left and right hand responses That is subjects responded to letters with the left hand and digits with the right hand for half of the experiment and they responded to digits with the left hand and letters with the right hand for the other half This is also indicated by the ERPLAB 7 of 55 Tutorial event codes for each stimulus i e the event code for the stimulus also indicates the appropriate response for that stimulus ERPLAB Toolbox makes no dis
36. d events to bins when creating the EventList structure This is fine for very simple experiments but it is insufficient for almost all real studies We will now consider how event are assigned to bins for typical studies using the BINLISTER routine see the ERPLAB User s Manual for more details To begin this example select the S1_Chan dataset The first step is to create an EventList When we did this before we used the advanced method which allows you to provide a label for each event code and to assign each code to a bin This time we will use the simple method which just creates the EventList with whatever event codes or event labels are in the dataset To do this select ERPLAB gt EventList gt Create EEG EventList Basic It will put up a small window giving youa few basic options but you should just click Create You can then accept the default name for the new dataset S1 Chan elist You can verify that the EventList was created by typing EEG EVENTLIST in the Matlab command window Now we are ready to start using BINLISTER The general approach used by BINLISTER is as follows Using a text editor such as the Matlab editor you will create a text file that provides an abstract description of the kinds of event sequences that should be assigned to each bin e g event code 20 preceded by event code 51 or 52 and followed 200 1500 ms later by event code 101 The abstract description for a given bin is called a bin descriptor and
37. documentation like the software is a work in progress Note This tutorial was written for a beta release that preceded the official public version 1 0 0 release and a few small changes were made for version 1 0 0 We will provide an updated tutorial soon The goal of this tutorial is to provide step by step instructions for the processing of a typical data set For an overview of ERPLAB Toolbox and detailed information about each specific function see the ERPLAB User s Manual A Frequently Asked Questions document is also available We have set up three web based discussion groups One is designed for people to ask questions and give and receive advice about how to use ERPLAB Toolbox Another is designed for reporting bugs and describing work arounds The third is designed to give users the opportunity to make suggestions about modifications and new features They can be accessed at http erpinfo org erplab erplab discussion erplab discussion forum you will need to join the erpinfo org web site to access these discussion groups There is also an email list erplab erpinfo org that you can use to communicate with the developers and with other users If you would like to join this list you should go to http mail01 cmb ucdavis edu mailman listinfo erplab Please keep in mind that this is FREE software and we do not have the resources to provide the level of support that commercial software vendors can provide ERPLAB 1 of 55 User s Manual
38. dow e n epochbinGul Bin based epoch time range ms 200 800 V Baseline correction Baseline Correction 2 None 1 Post _ Custom ms start stop Pre J Whole CANCEL RUN This window allows you to select the time period for the epoch relative to the event code Baseline correction will be enabled by default and you will almost always want to do this The prestimulus period Pre is usually the period used for baseline correction That is the average voltage during the prestimulus period for a given trial is subtracted from every point in the epoch separately for each channel Alternatively you can use the poststimulus interval Post the entire interval Whole or some time range of your choice Custom For this example you should leave it as Pre Click RUN and it will create a new dataset with the epoched data it will take a few seconds The standard window for saving a new dataset will appear you can just click Ok and it will name the new dataset S1 EEG elist be be stands for bin epoched However you should save the dataset to a file on your hard drive because it will be needed for completing the section on combining artifact rejection and artifact correction You can always do this later by selecting the appropriate dataset in the Datasets menu and then selecting File Save current dataset s or File Save current dataset as Make sure that this new dataset is the active dataset by looking in
39. e window shown in the screenshot below ERPLAB 19 of 55 Tutorial Moving Window Peak to Peak 200 0 798 0 1 16 2 M This routine finds the maximum peak to peak voltage within a moving window that slides across the epoch see the ERPLAB User s Manual for details You select the Test period which is by default the entire epoch note that the time values you selected in the epoching process have been rounded to actual sample times However sometimes you will want to search for artifacts only during a portion of the epoch You cannot of course look for artifacts outside of the epoch period because only the data from within the epoch period are present after the data have been epoched You must also choose a Voltage threshold An epoch will be rejected if the peak to peak voltage the difference between the largest and smallest values exceeds this value The appropriate value will depend on the nature of the artifact you are trying to reject and how large it is in a given subject see Chapter 4 in An Introduction to the Event Related Potential Technique for an overview of artifact detection You will then choose the length of the Moving window and the Window step This routine finds the peak to peak voltage within a window of the length specified in the Moving window field It then shifts the window by the amount specified in the Window step field and finds the peak to peak voltage within this new window This
40. ed you can take a look at the text version of the EventList that you created Simply open this file with your favorite text editor such as the Matlab editor For details on the contents and format of this file see the ERPLAB User s Manual Later on we will show how you can edit this file and import it back into your EEG data ERPLAB 17 of 55 Tutorial 7 Creating Bin Based EEG Epochs The next step after creating the EventList is usually to sort the events into different bins in preparation for averaging However we already did this by assigning bins for the rare and frequent stimuli when we created the EventList Once the events have been assigned to bins the next step is to divide the continuous EEG into a set of fixed length epochs also known as segments each of which is time locked to an event that has been assigned to a bin In the present example we will extract the EEG during a period that begins 200 ms prior to the onset of a stimulus and ends at 800 ms This will be done for each event code that has been assigned to a bin which is in the present example the frequent letters and rare digits not the responses Note that EEGLAB has an epoching function Tools Extract epochs you should not use this function if you are using the ERPLAB functions for processing the epochs e g averaging plotting etc Instead you should use ERPLAB gt Extract Bin based Epochs If you select this function you will see the following win
41. ed since last saved m Overwrite itin memory setzyes unset create new dataset Cancel Help Ok We find that it is usually a good idea to save the dataset to disk after you ve gone through several steps otherwise all your work will be lost if the program crashes And you should obviously save to disk if you are going to quit the program and you don t want to lose what you ve created However it usually isn t necessary to save every dataset you create this ends up leading to a lot of big files on your hard drive Also we don t usually overwrite the previous dataset because then we can t easily back up to the previous step However there are no hard and fast rules here you will eventually develop a set of habits that make sense for your own needs ERPLAB 15 of 55 Tutorial For this example you should save the new dataset to a file named S1_EEG_elist set but don t overwrite the old dataset Click Ok and the new dataset will be created this may take a few seconds Once the new dataset has been created you will see Done printed in the Matlab command window you will be able to see it in the Datasets menu as shown in the next screenshot oo EEGLAB v6 03b L File Edit Tools Plot Study ERPLAB Erpsets BBELEETAC L Dataset 1 51 EEG t 2 S1 EEG elist v Dataset 2 51 EEG elist J Filename none Select multiple datasets Channels per frame 16 Frames epoch 1069520 B Epochs 1 Events
42. ee T Mme Afros m UB mere A m vira Pl w AA v P4 d ce ac ete tel ST rae AV a P m pi AAA Pam s i ow thier F tte me Pl e we Mer www ipt neo eia Pulido rk PPP TP wa yn pem F A J e f pH Wieje ABA i Ar e Fp1 pp ae repe M ter bs Inte vo Rel hw pw rar a w k u MA fe nro yapapash re aA k JL Mn f ver Fp 2 Tayi awka aa M Ky J PPP mete 7 M LN e u ent AE NTE VL egg a L pui x a ee U M S ias Any Ihn rere a A eh pP awe NT ae ees nny MIR ve ra hue ys VAT naa pen W A F 8 r s i vw Ai wA J Ti Fz Nt J eS E E Yan Ss B nda a ng i e vio weed Mun wp w Cz u AA I re A ee M A o nm Pann paar het y go nan V aes a w um Nm om UA A UMEN T MEE Pz bre v E ums a h u rera ag ud us e qe fn m RET MR Ld frm M t 2 dis MEN OR M a vEOG Qm N W juin Scale n 2 rt nA 2 um Mc me T S E Mi Lu em RI VETT dece maw nni PE Pr 10 HEOG fo a lee hj eu alu T Chan Time Value CANCEL Eventiypes lt lt lt 0 gt gt HEOC 12648 10 0367 100 REJECT 14 Assigning Events to Bins with BINLISTER Up to this point we have assigne
43. ent this create a new text file called binlister demo 2 txt and put the following event descriptors in it bin 1 Frequent preceded by frequent and followed by correct response 11 122 22 111 8 9 11 122 22 111YX9 bin 2 Rare preceded by frequent and followed by correct response 11 122 22 111 8 9 21 112 12 1219 ERPLAB 48 of 55 Tutorial Run BINLISTER using this new bin descriptor file If the active dataset is the one you created by running BINLISTER in the previous example you will get a warning message asking you if you wish to overwrite the previous bin assignments you can say yes If you look at the EventList in test txt you will see that stimuli preceded by a rare stimulus and the response to the rare stimulus are no longer assigned to any bins It is often desirable to specify the time period of a response relative to a stimulus You can do this in the bin descriptor file by using the t lt start stop gt syntax We could change our first example to look for a stimulus followed by a response with 200 1000 ms as follows bin 1 Frequent followed by correct response 115122 22 111 t lt 200 1000 gt 9 bin 2 Rare followed by correct response 21 112 12 121 t lt 200 1000 gt 9 When you specify a time period for an event list this is called a time conditioned event list Ordinarily the events in the EventList structure must be in exactly the order specified by an event descriptor to be considered a match For ex
44. er the settings from the last time you used it but you can revert to the default settings by clicking the RESET VALUES button e g when you want to plot a new ERPset that has a different epoch length set of channels etc Hint Do not try to select a new ERPset while the plotting window is open The plotting window only knows about the ERPset that was active when the window was first opened We will eventually change this window so that you can select among ERPsets from the plotting GUI ERPLAB BETA 1 1 911 ERP Plotting GUI Bins to plot Channels to plot BINT Freq 1 14 1 V Include number of bin in legends show number of channel instead of label Time range to plot ms Mean Global Field Power 200 8 Show MGFP from channels Y scale Baseline Correction only for plotting purpose 2 None J Post Custom ms 5 91 11 17 Auto n Pre 2 Whole 200 0 Set frame s Line width Set fonts Legend pos Row s Column s Channel s Legend s Call Scalp Plot 4 2 1 10 2 40 bottom 4 Extras PDF V include toolbar on figure To raphic arrangement a idi 9 CANCEL PLOT RESET VALUES Maximize figure Click the PLOT button with the default values and you should see a window pop up like the one shown below At present ERPLAB will create a separate panel for each scalp site and overlay the selected channels In a future version we will make this more flexible so that you can plot multiple ERPs
45. et 3 51 EEG elist be v Dataset 4 51 EEG elist be Select multiple datasets DT Now select ERPLAB Compute Averaged ERP This will bring up the very simple window shown below You will normally average the data in the currently dataset which is listed by default in the Dataset s field If you want you can specify multiple datasets and average across them as if all the epochs were stored in a single dataset Here we will just average the epochs from one dataset so click RUN to start the averaging process ERPLAB BETA 1 1 0 30 WEIGHTED AVERAGER GUI Dataset s l 4 CANCEL RUN Exclude epochs marked during artifact detection highly recommended Include ONLY epochs marked with artifact rejection Be cautious Include confidence interval Std Hint If you have a lot of channels or a high sampling rate or both you may find that the datasets are so large that Matlab becomes very slow this is because only so much data can be stored in RAM and Matlab may start storing some of the data in cache on your hard drive which is very slow In this case you may wish to keep each trial block in a separate dataset and combine them into a single ERPset during averaging Normally you will want to exclude epochs marked as containing artifacts marked with artifact flag 1 in the EventList but you can include all trials by unchecking the Exclude epochs marked during artifact rejection box It is also possib
46. ets and choose which waveforms are overlaid and which waveforms are shown in different panels For now you can save the waveforms in a PDF file by clicking the PDF button import them into a graphics program such as Adobe Illustrator and then edit them We recommend that you maximize the figure window before clicking the PDF button Alternatively you can export the waveforms as text files using the ERPLAB Export ERP to Text routines and then read them into a program such as Excel or Deltagraph for plotting ERPLAB 28 of 55 Tutorial Figure 4 lt lt S1_ERPs gt gt Measuring Purpose Click on figure for larger imaqe File Edit View Insert Tools Desktop Window Help Gs b 49 sS a lt BOA E jette L A 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 03 04 27 5 5 5 0 n 0 D 0 yh 5 s 5 5 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 Ep2 FZ CZ 5 5 5 LA 5 5 5 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 DZ vEOG A2 HEOG i TAN i 5 5 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 200 0 200 400 600 BIN1 Frequent Category Digit BIN2 Rare Category Letter Note that when Include Toolbar is checked in the plotting GUI ERPLAB uses a standard Matlab plotting routine that provides a set of menus and a toolbar in the plotting window Play around with it and you should
47. hannels as in the first example of channel operations can make it easier to find and reject blinks so this is usually done prior to artifact detection In contrast re referencing to the average of the two earlobes won t usually change the results of artifact detection so you can do it either before or after artifact detection or even after averaging 13 4 Re referencing to the average of all scalp sites Using the average of all electrode sites as the reference called the average reference derivation is quite popular but it has some significant shortcomings that you should understand before using it see Chapter 3 in An Introduction to the Event Related Potential Technique The general approach used to re reference to the average of the two earlobes in the previous example could be used to create the average reference derivation but it would lead to very long equations e g ch1 ch1 ch1 ch2 ch3 16 To make this simpler ERPLAB provides the avgchan function which computes the average of a set of channels For example you might want to use the average of all channels except the VEOG and HEOG channels to re reference To do this you need the average of channels 1 13 and 15 excluding channels 14 and 16 which are the VEOG and HEOG channels which you can obtain by specifying avgchan 1 13 15 The following screenshot shows how this would be implemented you can load the equations from the file chanops avg reference txt
48. hat can be applied to continuous EEG to segmented EEG and to averaged ERPs Separate routines are used for filtering EEG ERPLAB Filter amp Frequency Tools gt Filters for EEG data and for filtering ERPs ERPLAB gt Filter amp Frequency Tools gt Filters for ERP data The routines are nearly identical except for a few options We will start by discussing the filtering of averaged ERPs Make sure that 51 ERPs is selected in the ERPsets menu and then select ERPLAB Filter amp Frequency Tools for ERP data You will see a window similar to the screenshot below This window allows you to set various properties of the filter First you can determine whether to apply a low pass filter filtering out high frequencies and or a high pass filter filtering out low frequencies For each of these you can select the 50 amplitude cutoff point by typing a number in the corresponding text field or by adjusting the sliders You can also adjust the slope of the filter s roll off in the Roll off amp filter order panel in units of decibels per octave dB oct or in units decibels per decade dB dec or in terms of the filter s order if you change one the others will automatically change You can see the frequency response function of the resulting filter the extent to which each frequency is passed by the filter in the graph at the top of the window assuming that the Plot panel is set to Frequency response Try playing around with the variou
49. ht have one bin for the infrequent targets and another bin for the frequent standards However a sophisticated experiment might have dozens of different bins with a given bin being something like Digits preceded by letters followed by a correct response between 200 and 1000 ms in a condition in which digits are rare and letters are frequent In many ERP analysis systems a bin would be equivalent to a single averaged ERP file However this can lead to a huge number of different files for each subject making it difficult to keep track of everything In ERPLAB an ERPset can contain an unlimited number of bins and each data processing operation is typically applied to all of the bins in the currently active ERPset This saves time and reduces errors ERPLAB 11 of 55 Tutorial 6 Creating an EventList We are now ready to get into the ERPLAB functions We will begin with some housekeeping then do artifact rejection and finally averaging The event codes are embedded in a dataset within EEGLAB s EEG structure which is pretty complicated To make it easier to see and manipulate the event codes ERPLAB creates an EventList which is a list of all of the event codes and associated information Internally ERPLAB stores this as an EVENTLIST structure which is appended onto the EEG structure as EEG EVENTLIST But the EventList can also be saved in a text file where you can easily see and manipulate the event information If you make any
50. ith marking those trials in which a blink occurred during the stimulus presentation we will limit the test period to the time range immediately surrounding the stimulus event code 200 to 200 ms optimal parameters will depend on the duration of the blink you can try varying this window to see whether it reliably detects blinks at the time of the stimulus and not blinks at other times We will use only the VEOG channel 14 to detect blinks Finally be sure to select a flag so that we can uniquely label epochs in which blinks occurred Here we have chosen Flag 8 ERPLAB 53 of 55 Tutorial AOC Blink Detection Test period start end ms 200 0 200 0 Blink Width ms 400 Normalized Cross Covarianze Threshold 0 7 Channel s Mark Flag flag 1 is reserved OOOO Reset Values Cancel Accept After clicking on Accept you can see in the command window output that 1 6 of trials are detected as having blinks in this time period Scroll through the EEG data viewer window that has appeared and see which epochs have been marked as we did in the earlier examples of artifact detection Note that most of the blinks have not been detected because they did not occur at the time of the stimulus However blinks at the time of the stimulus were rejected In particular note epoch numbers 68 121 166 221 262 Epoch 68 is shown below and it is clear that this blink occurred at the time of stimulus presentation as i
51. ities eegplot fay E ay 1 ir 8 8 Figure Display Settings Help Chan Time Value CANCEL Event types lt lt 2 gt 15 3524 18 5497 SS REJECT Scroll through the data for a while and play with the plotting routine if you haven t used it before You might want to change Settings Time range to display to 30 seconds within the plotting window Eventually around 120 seconds you will see a period with no event codes and lots of artifacts This is a short rest break about 1 4 of the way through the trial block You ll see another period like this at 255 seconds and 390 seconds The trial block ended at approximately 525 seconds and the file ended at 535 seconds You will see a boundary event label at this point which is where the second trial block was appended after the first trial block If you keep going past the boundary event you will start to see some numeric event codes In this simplified example of creating an EventList we assigned labels only to the event codes for the stimuli that were used in the first block of trials along with the responses for the entire session You don t need to assign labels for all of your event codes or even any of them However having the labels makes it much easier to link the signals that you see in the EEG to specific types of events especially in experiments with dozens of different event codes If you re interest
52. ked dataset or select ERPLAB Artifact Detection Clear Artifact Detection Marks on EEG which then displays the following figure BSO ERPLAB BETA 1 1 814 Reset Artifact Rejection GUI To reset the artifact detection marks make sure Reset Artifact Rejection Marks Reset Flags and All flags are selected then click OK After you click OK a window pops up prompting you to name the new dataset ERPLAB 22 of 55 Tutorial To see how this works let s take the dataset that you ve already marked with rejections using the Moving window peak to peak threshold test and apply another test the Step like artifacts test In this example we will attempt to detect horizontal eye movements in the HEOG channel channel 16 Saccadic eye movements have a distinctive shape because the eyes are steady at one location for a period of time then jump to another location stay steady for a period of time and then jump to yet another location so the HEOG signal is relatively flat suddenly jumps to a new level stays flat for a period of time and then jumps to a new level In many cases the eyes are on the fixation point jump away for a few hundred milliseconds and then jump back to fixation When this happens the HEOG signal has a boxcar shape as in the screenshot shown below Scroll channel activities eegplot Figure Display Settings Help be Rare Let 208 150 100 50 20 100 150 200 250 300 350 400 450 500 350 600 650 700
53. lar gt sph amp xyz Spherical azimuth angle sph_phi 27 973 Spherical radius sph radius 85 Set head radius Channel type Set channel types Index in backup urchanlocs structure 1 Delete chan Channel number of 16 Insert chan lt lt lt 1 gt gt gt Append chan Plot 2 D Plot radius 0 2 1 auto _ Nosealong X Plot 3 D xyz Read locations Read locs help Look up locs Save as ced Save other types Cancel Help Ok For simple data files such as the one used in this tutorial you can accept all of the default values and simply click Ok This will add the coordinates to the current dataset EEGLAB and ERPLAB require electrode coordinates for plotting topographic maps you will get an error message if you try to plot a topographic map before you ve added the coordinates You can ERPLAB 9 of 55 Tutorial verify that the coordinates have been added by running a routine that plots topographic maps For example if you select Plot gt Channel spectra and maps and select the default parameters in the window that appears as shown in the screenshot below Channel spectra and maps pop spectopo Epoch time range to analyze min ms max ms 0 2139038 Percent data to sample 1 to 100 15 Frequencies to plot as scalp maps Hz 6 10 22 Plotting frequency range lo Hz hi Hz 225 Spectral and scalp map options see topoplot electrodes off Cancel Help Ok Click OK and you will see the foll
54. le to include only the epochs that contain artifacts excluding epochs without artifacts by checking the Include ONLY epochs marked during artifact detection box The averaging routine will print some useful information in the Matlab command window as shown in the screenshot below Specifically it will show the percentage of trials that were excluded because of artifacts and because of invalid trials e g epochs with boundary events within them invalid trials should be rare This information is provided both collapsed across bins and separately for each bin ERPLAB 26 of 55 Tutorial Averaqinq dataset 4 averaqer m START The dataset 51 EEG elist be ar has a 27 8 of rejected trials The dataset 51 EEG elist be ar has a 0 0 of invalid trials TOTAL The dataset S1 EEG elist be ar has a 27 8 of discarded trials Summary per bin Bin 1 was created with Bin 1 was created with 29 3 of rejected trials 0 0 of invalid trials Bin 2 was created with 21 9 of rejected trials Bin 2 was created with 0 0 of invalid trials averager m END Done When the averaging routine is finished it will display the window shown below that allows you to name and save the ERPset that was created This window is shown every time an ERPLAB function modifies or creates an ERPset If one or more ERPsets were already loaded you would have the option of overwriting the previously active ERPset or creating a new ERPset you will usually wan
55. locations No labels only ICA weights Dataset size Mb dress Book You can now look at the data with Plot gt Channel data scroll as shown in the following screenshot see the EEGLAB documentation for information about how to use this function FU 08 Scroll channel activities eegplot Figure Display Settings Help cs wenn LL Made Chan Time Value CANCEL Eventtypes rs mi HEOC 3 8984 36 9471 59 oe If you scroll 10 seconds by clicking the gt gt button twice you will see vertical lines and numbers which show the event codes aka stimulus markers trigger codes as shown here ERPLAB 6 of 55 Tutorial Figure Display Settings Help Chan Time Value cANcEL Event types lt lt 59 116877 15 9787 59 REJECT 3 A Brief Description of the Example Experiment The initial examples come from a published experiment In this section we will provide a basic overview of the experiment along with a few of the details you will need to know to analyze it For a complete description of the experimental paradigm see the publication Luck et al 2009 Psychophysiology 46 776 786 This study examines the P3 wave and the lateralized readiness component LRP in a group of schizophrenia patients and a group of matched control subjects This tutorial focuses on the data from 6 of the control subjects in the folders named S1 S6 but note that some releases
56. me way in the independent transformations mode except that the left part of each equation would start with nch1 nch2 etc rather than ch1 ch2 etc The set of equations is fairly long so you may want to load it from the file chanops avg earlobes txt You can see that each channel is updated to equal its original value minus half of channel 15 A2 with the exception of channels 15 and 16 These channels are simply equal to themselves It isn t actually necessary to define these channels as being equal to themselves when updating an existing dataset because the channels are already there but it can be useful to include this as a reminder that these channels are present When everything is ready click RUN This should update the current dataset If you plot the data before and after re referencing you should be able to see small differences e 0 ERPLAB BETA 1 1 814 Channel Operation GUI for EEG ch1 ch 0 5 ch15 label Existina Channels ch2 ch2 0 5 ch15 label F4 ch3 ch3 0 5 ch15 label C3 2 F4 ch4 ch4 0 5 ch15 label C4 on ch5 ch5 0 5 ch15 label P3 5 P3 ch6 ch6 0 5 ch15 label P4 6 P4 ch7 ch7 0 5 ch15 label F7 7 ch8 ch8 0 5 ch15 label Fp1 8 FP1 ch9 ch9 0 5 ch15 label Fp2 Q FP2 ch10 ch10 0 5 ch15 label 10 F8 ch11 ch11 0 5 ch15 label Fz 11 2FZ ch12 ch12 0 5 ch15 label Cz 12 2 CZ Ch13 ch13 0 5 ch15 label Pz 13 2 ch14 ch14 0 5 ch15 label VEOG 14
57. mn shows the bin epoch bepoch number which is the item number after epoching These numbers will be different when some event codes are not used as time locking events when the data are epoched e g the response event codes in the current example If you are trying to find an event in the continuous data with Plot Channel data scroll you should use the item number first column If you are trying to find an event in the epoched data you should use the bepoch number second column Note for programmers The flags are shown in a binary format in the text file to make it easier to see the individual flag values However they are stored in a single variable and Matlab ordinarily uses decimal numbers to enter and print the value of a variable For example If you set flags 1 and 5 in an artifact detection tool and you print out the value of the flag variable you will see a value of 17 9 Creating Averaged ERPs We are now finally ready to create a set of averaged ERP waveforms First make sure that the correct dataset is active S1 EEG elist be which has been epoched and scanned for artifacts with the Moving Window peak to peak threshold artifact detection function Your Datasets menu should look something like the screenshot below ERPLAB 25 of 55 Tutorial o H D m m m m m m m m m 1 1 2 1 1 2 Erpsets Datasets Help Dataset 1 51 EEG Dataset 2 51 EEG elist Datas
58. mponent does not mean that we should necessarily include all corrected trials in our analysis For example if the participant blinks during the presentation of a stimulus this trial that should not be included because a participant can t see a stimulus if his or her eyes are closed due to a blink It is important to keep in mind that artifact correction can correct the artifactual voltage associated with an ocular artifact but it cannot correct the change in sensory input caused by an eye blink or eye movement The tricky part of combining artifact rejection and artifact correction is that once the artifact correction has been performed it is impossible to detect which trials contained a blink at the time ofthe stimulus Thus we need to perform artifact detection on uncorrected data and merge this information with the corrected EEG This is made even more complicated by the fact that we detect artifacts after epoching the EEG but artifact correction is usually best performed on the continuous EEG Accomplishing this involves the following set of steps e Use ICA to create a continuous EEG file in which the blinks have been corrected ERPLAB 50 of 55 Tutorial e Using the uncorrected epoched EEG file find trials with a blink at the time of the stimulus e Save the EventList from this file which marks which events contained the artifacts mportthe EventList that marks the artifactual trials into the corrected continuous EEG file Epoch
59. n You will then be asked how to save the new dataset Name it S1 Chan biVEOG you can also save it to the disk if you d like If you plot it using Plot Channel data scroll you will see something like the following screenshot you may need to increase the plotting scale to make it look like this Note that the blinks look somewhat larger in the new biVEOG channel than in the original VEOG channel ERPLAB 43 of 55 Tutorial 13 3 Re referencing to the average of the left and right earlobes or mastoids You can also use Channel Operations to re reference your data to a common derived reference such as the average of the left and right mastoids the average of the left and right earlobes or the average of all scalp sites In this example we will re reference to the average of the left and right earlobes the next example will show how to re reference to the average of all electrodes To begin re load the S1 Chan dataset Each channel in this dataset with the exception of HEOG was originally referenced to the left earlobe A1 To re reference to the average of the left and right earlobes we need to subtract 5096 of the right earlobe A2 signal from all of the sites see pp 107 108 in Luck 2005 But we don t want to re reference the A2 site or the HEOG site This would be done using the equations shown in the screenshot below In this example we are updating the existing dataset recursive mode but it would work exactly the sa
60. n in a given dataset you can select ERPLAB gt Artifact Detection gt EEG Artifact Detection Summary Table This will print a table of the number of trials marked for rejection in each bin along with the number of occurrences of each flag which ordinarily corresponds to different types of artifacts You can also select ERPLAB Artifact Detection EEG Artifact Detection Summary Plot which will show the distribution of artifacts across channels You can also get this information after averaging with ERPLAB Artifact Detection ERP Artifact Detection Summary Table Imagine that you want to do artifact rejection twice once on the VEOG channel with a relatively low threshold e g 75 uV and short moving window length e g 200 ms to detect blinks and once on all the other channels with a relatively high threshold e g 200 uV and long moving window length e g 1000 ms to detect other kinds of artifacts e g EMG bursts skin potentials etc You can simply run the artifact detection routine once with one set of parameters save the dataset and then run the artifact detection routine on this new dataset with a new set of parameters Any artifacts marked in the dataset prior to artifact detection will remain marked when artifact rejection is performed on that dataset and any additional artifacts will be marked in the new dataset If you wish to unmark everything and start over you can either clear the datasets and go back to an unmar
61. n order to better view the data You will see something very similar to the figure below although likely not identical since ICA does not always return precisely the same solution It is clear that the activations of component 1 line up in time with the occurrence of blinks in the data ERPLAB 51 of 55 Tutorial 000 Scroll channel activities eegplot Figure Display Settings Help Chan Time Value 07 gt 8 eoc 24073 1 517 TO 800 component activities eegplot l on Chan Time Value Eventtypes z amp 9 1 15616 Coo Next we want to remove this component from the data do this select Tools gt Remove Components and enter 1 in the uppermost box assuming it was component 1 that resembled blinks in your ICA results as well After selecting Ok a window will appear asking you to confirm this decision Confirmation Please confirm Are you sure you want to remove these components Cancel 11 PlotERPs Plotsingle trials Accept ERPLAB 52 of 55 Tutorial Ifyou click on the button Plot single trials you can view the original EEG superimposed with the corrected EEG that results from removing the component s that you have selected It will look something like this screenshot Black channel before rejection red after rejection eegplot Figure Display Settings Help Chan Time Value 15 3 8019 10473
62. n the screenshot below selecting a high pass filter with a cutoff at 0 1 Hz and a low pass filter with a cutoff at 30 Hz You should check the boxes for applying the filter to segments defined by boundary events which you should always check unless you really know what you re doing and for removing the mean value which you should always do with DC recordings and which won t hurt for non DC recordings The ERPLAB User s Manual provides more details Band pass 246 0317 Once you ve set the parameters click APPLY The filtering will take a little while Once it prints Done in the Matlab command window use Plot Channel data scroll to see the filtered data which should look like the screenshot below ERPLAB 36 of 55 Tutorial Scroll channel activities eegplot Figure Display Settings Help Chan Time Value CANCEL Eventtypes lt lt 2 gt gt 40764 2 5364 DOr REJECT Hint In most cases high pass filters should be applied to the continuous EEG not the epoched EEG or averaged ERPs The reason is that with typical cutoff values a long period of continuous data is needed for these filters to work properly Low pass filters can be applied at any time because they do not need a very long time period with typical settings In most cases however it is best to apply low pass filtering after averaging Otherwise you will need to back up to the EEG and repeat several steps if you later decide to
63. ndicated by the fact that it surrounds the stimulus event code Note that the bin marker has replaced the stimulus event code Blink rejection alpha version view Figure Help Bi Frequent HB nmm I TT E ii PIPPHifirisii bd E ws id VA W we pl ya h E E Chan Time Value _ MES jEventypes 68 HEOC7794911 07936 804 ERPLAB 54 of 55 Tutorial Now that we ve detected the trials that we want to exclude in the uncorrected EEG data we need to save the current EventList to a text file so that we can import it back into our ICA corrected dataset To do this select ERPLAB gt EventList gt Export EEG EventList to text file Enter EventList blinkdetection txt as the filename and click Save If you open this text file in your favorite text editor you can scroll down to the event numbered 135 this was event 135 prior to epoching but it was event 68 after epoching because the response events were not assigned to bins and did not generate epochs As you can see this was one of the events we detected Both the 1st and 8t flags are present Remember the 1 is always flagged when an artifact is detected for that bin We chose also to label the artifacts detected by this step with the 8 flag item bepoch ecode label onset diff dura b flags a flags enable bin sec sec msec binary binary 132 0
64. not necessary so that you can easily step backward and try again if you make a mistake or change your mind 13 Creating and Modifying Channels with Channel Operations We will now discuss how you can create and modify channels The most common use for this is to re reference all or most channels to a different reference electrode or combination of electrodes A second use is to create a bipolar channel that better isolates an artifact signal This can be done either on the EEG in a dataset ERPLAB EEG Channel Operations or on the ERPs in an ERPset ERPLAB ERP Channel Operations ERPLAB 40 of 55 Tutorial Like Bin Operations Channel Operations has two modes of operation see the Mode region at the bottom rightin the screenshot below In one mode you use a set of equations to modify existing channels and add new channels within the current dataset or ERPset In this mode you can modify one channel and then use this modified channel to create or modify another channel this is called recursive updating In another mode the current dataset or ERPset serves as the input to a set of equations that create a new set of channels in a new ERPset this is called creating a set of independent transformations Either mode can be used for most situations but only the independent transformations mode can be used to re order the channels and the recursive updating mode can be more efficient for certain complicated transformations We will sh
65. ot both By checking this box you will have the opportunity to transfer your newly created labels into EEG event so that they will be available for use by EEGLAB functions such as the function for plotting the EEG data Once you have entered all of the necessary information into the window as shown in the screenshot above click the APPLY button to create the EventList and add it to the current dataset The information about event mapping must be stored in a file Therefore if you have made any changes in this information the following window will appear eoo Save List of changes Save and Continue SeveAs If you select Save and Continue it creates the EventList and will put up the window shown in the next screenshot assuming that you checked the Transfer EVENTLIST info to EEG event box This window allows you to choose whether to store the event codes the event labels or the bin numbers in the EEG event structure The default is Code Labels and selecting this will allow you to see the labels for each event code when you look at the EEG using EEGLAB s Plot gt Channel data scroll routine Keep this default setting and click the APPLY button ERPLAB 14 of 55 Tutorial ERPLAB 1 1 814 Warning The EEG event info will be overwritten by the EVENTLIST eventinfo s Events to use as TYPE _ Numeric Codes Code Labels _ Bin Labels CANCEL APPLY att
66. ow examples of both modes here 13 1 Creating a bipolar VEOG channel by updating the current dataset In our first example we will take the VEOG signal which was recorded as the potential between an electrode under the left eye and a left mastoid reference electrode and create a bipolar derivation representing the difference between the potential under the eye and the average of the Fp1 and Fp2 electrodes To get started make sure that the S1 Chan dataset is loaded and selected in the Datasets menu and then select ERPLAB EEG Channel Operations This will bring up the window shown below The right panel shows the channels in the current dataset and the left panel shows a set of equations that will be used to define the bins in the newly created dataset In this example we will create a new channel channel 17 that is the difference between the original unipolar VEOG channel channel 14 and the average of Fp1 and Fp2 channels 8 and 9 giving the new channel the label biVEOG Put the equation for this new channel into the panel on the left side of the window as shown in the screenshot below And because we are updating the current dataset make sure that Modify existing dataset recursive updating is selected ERPLAB BETA 1 1 721 Channel Operation GUI for EEG Ch17 ch14 ch8 ch9 2 label biVEOG 74 O0 Qn wr 3323997 II NANG il m G 10 11 12 13 14 15 28
67. owing plot Figure 2 spectopoO File Edit View Insert Tools Desktop Window Help Dg hb oa 9 D E 5 9 9 8 22 0 Hz Power 10 lo u V Hz Later parts of this tutorial will make use of this dataset so you should save itto disk First however you should change the name of the dataset to S1_Chan so that you can differentiate between this version and the original version To do this select Edit gt Dataset info This will bring up the window shown below and you should enter S1_Chan in the Dataset name field Click Ok and then look in the Datasets menu You should now see that it is named S1 Chan ERPLAB 10 of 55 Tutorial Edit dataset information pop editset Dataset name S1 Chan Data sampling rate Hz 500 Subject code Time points per epoch 0 continuous 1069520 Taskocondition Start time sec only for data epochs 0 Session number Number of channels 0 gt set from data Subject group Ref channel indices or mode see help About this dataset Enter comments Channel location file or info From other dataset Browse Note The file format may be auto detected from its file extension See menu Edit gt Channel locations for other options ICA weights array or text binary file if any From other dataset Browse ICA sphere array or text binary file if any From other dataset Browse ICA channel indices by default all From other dataset Cancel Help Ok You can now save
68. p after epoching is usually artifact detection ERPLAB makes a distinction between artifact detection and artifact rejection Artifact detection is the process of marking epochs that contain artifacts Artifact rejection is the process of excluding trials containing artifacts The ERPLAB artifact detection routines do not throw out any data epochs with artifacts are merely marked Artifact rejection occurs during averaging marked epochs are simply excluded from the averaging process EEGLAB contains routines for artifact detection Tools Reject data epochs and also allows you to manually delete sections of data with artifacts from within the Plot Channel data scroll window The manual deletion is permanent although you can always go back to a previous version of the data in which the data have not been deleted Manual deletion also causes the insertion of a boundary event Manual deletion is performed on continuous data whereas artifact detection is performed on epoched data You can in principle combine EEGLAB s artifact detection routines with ERPLAB s artifact detection routines but this has not yet been thoroughly tested ERPLAB s artifact detection tools are mostly still in development However two of these tools are ready for use peak to peak and step function Make sure that your epoched dataset is active 51 EEG elist be and select ERPLAB gt Artifact Detection gt Moving Window Peak to Peak Threshold You will see th
69. quent Digit Corr Resp Rare Letter Corr Resp Frequent Digit Corr Resp Frequent Digit Corr Resp Rare Letter onset sec 117 118 118 119 151 151 152 152 153 153 154 5840 2980 7840 7060 0400 4560 2140 6720 4380 8940 8120 O COP P ORP OOO O diff sec 3800 7140 4860 9220 3340 4160 7580 4580 7660 4560 9180 dura msec 0 COP CONAM PO O O OO 0 O O OCO O O OO O b flags binary 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 a flags binary 00001001 00000000 00000101 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00001101 enable If you look at the column of artifact rejection flags a flags you will see that every rejected trial has flag 1 set the rightmost flag Some of the events have flag 4 set from the peak to peak routine e g item 157 Other events have flag 3 set from the step function routine e g item 159 and other events have both flags 3 and 4 set e g item 167 indicating that both types of artifacts were detected This information can be useful if you want to perform behavioral analyses excluding trials with specific types of artifacts Note that the left column in this text file shows the original item number of the event from the original continuous dataset The second colu
70. rs left hand response and 20 digits right hand response 2 2096 letters left hand response and 80 digits right hand response 3 8096 letters right hand response and 20 digits left hand response 4 20 letters right hand response and 80 digits left hand response Each block was originally recorded in a separate file These files were imported into EEGLAB using File Import data From Neuroscant CNT File and then merged together with File Append datasets The procedure you follow will depend on your data acquisition system Note that EEGLAB places a boundary event code at the boundary between the original files to mark the fact that a temporal discontinuity was present at those times This is important because some functions e g filters either implicitly or explicitly assume that consecutive data points in the EEG reflect temporally consecutive moments in time see the section on boundary events in the ERPLAB User s Manual The end result was saved in a file named S1 EEG set or S2 S3 etc to indicate each individual subject 4 Adding Channel Locations to your Dataset Before we start using ERPLAB s functions we ll use one of EEGLAB s functions that will prove useful at a later stage Specifically we will add location coordinates for each electrode site see the EEGLAB documentation for more information Our original data file contained electrode labels ERPLAB 8 of 55 Tutorial conforming to the
71. s filter parameters to see how it changes the frequency response function ERPLAB 33 of 55 Tutorial Three general classes of filters have been implemented First IIR Butterworth is a digital implementation of the classic Butterworth filter The output of this filter feeds back into its input making it an infinite impulse response filter It filters the data in both directions avoiding any phase shift Second FIR is a finite impulse response filter that uses a sinc impulse response function This kind of filter can be very efficient but can produce artificial oscillations in the filtered data under some conditions We will eventually implement Gaussian impulse response functions but have not done so yet However the sinc filter approximates a Gaussian when a relatively low filter order is used The third option is Parks McClellan Notch which provides a notch filter which attenuates one narrow range of frequencies and passes everything else Filters can dramatically distort your data creating artificial peaks and oscillations see Chapter 5 in An Introduction to the Event Related Potential Technique To avoid these distortions we recommend that you choose a high pass cutoff of 0 1 Hz or lower and a low pass cutoff of 20 Hz or higher unless you really know what you re doing We also recommend a roll off slope of 12 dB octave For an example of how severe filtering can lead to incorrect conclusions see Yeung et al 2007 Psychophysiology 44
72. secutive with no breaks but event codes need not be consecutive and they can be any integer number that Matlab can represent Because you will need to do this step for every subject you can save the table of event information in a text file by clicking save list and then load it in again for the next subject by clicking open list If you want you can load the file event mapping 1 txt which contains the table of events for this example You can edit this file with a text editor such as the Matlab editor which is more convenient than using the ERPLAB GUI for large tables of event information The format is pretty obvious you can open the event mapping 1 txt file with a text editor to see the format ERPLAB 13 of 55 Tutorial 22 Frequent_Digit 1 Frequent Category Digit 12 Rare_Letter 2 Rare Category Letter Corr_Resp me Err Resp In this example we will save the EventList in a text file to lookatitlater To do this check the box labeled EventList Text File and click the Browse button to save the file as elist txt The txt extension is not required but it s a good idea The check box labeled Transfer EVENTLIST info to EEG event should be checked EEGLAB keeps track of event information in the EEG event structure and EEGLAB doesn t know anything about ERPLAB s EventList Moreover the EEG event structure can store either a numeric event code or a text based event label for a given event but n
73. t to create a new one ERPsets are usually much smaller than datasets and you will not usually run out of RAM because of ERPsets In this case however no other ERPsets are present so you will be creating a new ERPset You should name the ERPset S1 ERPs This is the name that will be shown in the ERPsets menu You will usually want to save the results of averaging in a file on disk so select the Save ERP as button and give the file the same name as the ERPset name You can do this easily by clicking the same as erpname button The file will be saved in Matlab s current directory unless you either specify an alternative path or use the Browse button You can click the OK button once you have set up the window as shown in the screenshot below ERPLAB BETA 1 1 814 Save Erpset GUI S1 EHPs erp same as erpname Browse You can now see the newly created ERPset in the ERPsets menu as shown in the screenshot below dps Datasets Help w Erpset 1 51 ERPs 10 Plotting Averaged ERP Waveforms Now that you have created an ERPset you can look at its contents by selecting ERPLAB gt Plot ERP Waveforms which brings up the window shown in the next screenshot The top half of the ERPLAB 27 of 55 Tutorial window allows you to specify what information to plot bins channels etc and the bottom half allows you to control the details of the plotting vertical scale line width font size etc The window will rememb
74. t follow the time locking event In Bin 1 for example we are looking for any frequent stimulus event codes 11 122 22 or 111 followed by a correct response event code 9 Because the event list immediately after the dot contains the list of stimulus event codes the stimulus event code will be the time locking point In this example response locked averages could be specified by place the dot after the stimulus event list and before the response event list e g 11 122 22 111 9 Bins must be specified in order beginning with Bin 1 The line after the bin number is the bin description and it is used to help you keep track of what is in each bin To try assigning events to bins type the two bin descriptors shown above into a text file and save it as binlister demo 1 txt Then select ERPLAB gt Assign Bins BINLISTER S1 Chan elist should be the active dataset The window shown in the screenshot below will appear Load the bin descriptor file that you just created and type test txt into the name of the text file for writing the results Ordinarily you will not need to save the results to a text file but this will help you see exactly how BINLISTER is working Now make sure that everything else is set as shown in the screenshot and then click RUN ERPLAB 47 of 55 Tutorial 000 ERPLAB 1 1 721 BINLISTER GUI AUsers luck Documents Software Development ERPLAB Toolb BINLISTER will take some time to go
75. t into EEGLAB do this select File gt Load existing dataset from the EEGLAB GUI and open the file S1 EEG set This file is what EEGLAB calls a dataset and it stores EEG and related information The file is fairly large and EEGLAB will probably take several seconds to load it EEGLAB prints some information in the command window while it is processing the file finishing with Done when the file has finished loading Both EEGLAB and ERPLAB print useful information such as this in the command window and you should get in the habit of keeping an eye on this window Hint Using EEGLAB and ERPLAB requires a little bit of patience If you try to start the next procedure before the current procedure is done you will cause problems that will ultimately slow you down This is especially true of procedures that create or load datasets So just take a sip of coffee and wait until you see Done in the command window before you take the next step When the dataset has finished loading it will be visible in the Datasets menu as shown in the following screenshot ERPLAB 5 of 55 Tutorial eoo ____ EEGLAB v6 03b File Plot Study ERPLAB rpsets atasets 1 S1_EEG v Dataset 1 51 EEG Select multiple datasets Filename tion Tutorial S1 S1 EEG set l Channels per frame 16 Frames per epoch 1069520 Epochs 1 Events 2557 Sampling rate Hz 500 Epoch start sec 0 000 Epoch end sec 2139 038 Average reference No Channel
76. the Datasets menu and then select Plot Channel data scroll The following screen shows what it should look like It looks like you still have continuous EEG data but if you look more closely you will see a vertical dashed line 800 ms after and 200 ms before each event This dashed line marks the end of one epoch and the beginning of the next If you find this disconcerting you can simply change Settings Time range to display to a period of 1 second in the plotting window Hint EEGLAB routines typically ask you to enter time information in seconds whereas ERPLAB routines typically ask for milliseconds ERPLAB 18 of 55 Tutorial ANA Scroll channel activities eegplot Figure Display Settings Help Bi Frequent Bi Frequent Be Rare Let Bi Frequent Bi Frequent F3 F4 C3 C4 P4 F7 FP FP2 F bia F8 hl wi T hi FZ Man ME cZ Ww Pz vEOG A2 HEOG Chan Time Value is 1 gt gt gt HEOG 2867822 0 49612 31 Because the epoch length in this experiment is shorter than the interval between consecutive stimuli the epoched data will now be missing a period of time between the end of one epoch and the beginning of the next epoch If however we used a 2000 ms epoch length the last part of one epoch would contain the same EEG data as the beginning part of the next epoch 8 Artifact Detection The next ste
77. the file containing the bin descriptors is called a bin descriptor file BINLISTER reads this file and then scans the EVENTLIST structure ERPLAB 46 of 55 Tutorial Each event is compared with each of the bin descriptors If itmatches one or more of the bin descriptors the list of bins for that event is updated The first and hardest step is to create the bin descriptor file As a reminder here is a table showing the stimulus event codes The event codes for responses in this experiment indicated whether the response was correct event code 9 or incorrect event code 8 rather than directly indicating whether a left hand or right hand response was made Category Letter Digit Letter Digit Letter Digit Letter Digit We will start with an example in which we collapse all the rare stimuli together into one bin Bin 1 and all of the frequent stimuli together in a different bin Bin 2 And we ll include only trials in which the stimulus was followed by a correct response Here are the bin descriptors for these two bins bin 1 Frequent followed by correct response 11 122 22 111X9 bin 2 Rare followed by correct response 21 112 12 121X9 Each pair of curly brackets defines an event list which specifies or more events that must occur at a given sequential position The event list following the dot specifies the identity of the time locking event and the following event lists define the events that mus
78. the modified dataset by selecting File Save current dataset as We recommend that you give the file the same name as the dataset but with a set extension S1 Chan set 5 Background Concepts Datasets ERPsets and bins There are a few key concepts you need to understand before we go any further EEGLAB stores a set of EEG data in something called a dataset A dataset typically stores the data from a single subject either a single block of trials or an entire session A dataset is maintained in memory inside EEGLAB and it can also be saved on disk Whenever you run a routine that changes the data in a dataset a new dataset is created You can see the currently available datasets in the Datasets menu One dataset is currently active and any routines that you run will typically be applied to the current dataset When a new dataset is created it becomes the current dataset but you can make a different dataset active by selecting it in the Datasets menu This provides a very convenient workflow ERPLAB defines an analogous structure called an ERPset which stores a set of ERP waveforms They can be active inside ERPLAB and or saved to disk The ERPsets menu can be used to see which ERPsets are currently loaded into ERPLAB and to change which ERPset is active A bin is a set of averaged ERP waveforms one for each electrode site which were created by averaging together a specific set of EEG epochs A simple oddball experiment for example mig
79. tinction between stimulus event codes and response event codes This gives the user more power but it also gives the user responsibility for using the event codes in a sensible way The event codes for responses in this example experiment indicated whether the response was correct event code 9 or incorrect event code 8 rather than directly indicating whether a left hand or right hand response was made However the combination of the stimulus event code and the response event code makes it possible to determine whether the subject pressed the left button or the right button Here is a table showing the stimulus event codes Category Letter Digit Letter Digit Letter Digit Letter Digit The data in this experiment were recorded from a 16 bit Neuroscan Synamps system with a bandpass of 0 05 100 Hz and a sampling rate of 500 Hz Each scalp site was recorded relative to a right earlobe reference Recordings were also obtained from a vertical electrooculogram VEOG electrode located beneath the left eye and from an electrode on the left earlobe both referenced to the right earlobe A horizontal electrooculogram HEOG signal was recorded as the potential between electrodes located just lateral to each eye Letters and digits were presented in an unpredictable order within each trial block but separate blocks were used for each combination of probability response assignment That is there were separate trial blocks for 1 8096 lette