Home

User Manual - DMS International

image

Contents

1. counts is 2 000 0 1 999 2 For Index 0 999 the lower right dot 1k Indicator will not light on 3 For Index 1 000 1 999 the lower right dot 1k Indicator will light on Index 888 Index 1 888 we 1K Indicator Lights on P2 ee Cable Connection 1 connect the Motor to the terminals printed M1 amp M2 and connect the Reed Switch Sensor to the terminals printed SENSOR via Motor Cable p s The wrong connection between Motor amp Sensor might damage the Reed Switch Sensor on the Actuator 2 Connect one coaxial cable RG 6 U is recommended from the receiver to the rear Panel of the positioner printed To Receiver Connect another coaxial cable from the Positioner to the LNB 3 Plug the AC Power Cord into the AC outlet 1 dots of the LED display will light on Now is the stand by mode The power of the Positioner will be turned on off automatically while the LNB power of receiver is turned on off TV Caaxial Cable Coaxial Cable Recciver Remote Control of Receiver Optional Remote Control Actuator or H H Meunl P3 gt K For any Receiver optional Remote Control is necessary Set the Software High Low Limits Setting the software High Low limits are recommended for better protection even if there are Hardware Limit Switches on the actuator or H H mount However the Positioner can be Operated without setting the software H
2. DISEqC 1 2 Positioner USER MANUAL DiSEqC 1 0 1 2 Receivers Compatible Work with any Receiver via Optional Remote Control Compatible with any Actuator or H H Mount 99 Programmable Memories Easy Operation and Quick Installation Fine tune Function for Better Reception Anti Noise Circuit to avoid miscounting Short Circuit and Overload Protection Software Limits Protection Auto Turn off Function Re Calculate Adjust Shift Function Lock Key Protection nisc pista Content Page 1 Optional Remote Control v s Receiver P1 2 Basic Operation P2 3 Cable Connection P3 4 For any Receiver P4 Optional Remote Control is necessary 5 For DiSEqC 1 2 Receiver P7 6 For DiSEqC 1 0 Receiver P9 7 Trouble Shooting P10 8 Quick Table P11 9 Display Description P12 10 Specification P12 The picture and the description maybe different from the practicality please do on the basis of the practicality This subject may change without further notice Safety Precautions 1 The ventilation should not be impeded by covering the ventilation openings With items such as newspapers table cloths curtains etc 2 No open flame sources such as lighted candles should be placed on the apparatus 3 The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus 4 Notice Don t Reboot in 15 seconds after AC power down Or you will need to Reset the box ce T
3. al Remote Control C Key on Remote Control C Button on Positioner Power ON OFF orl amp Manual East West 4E _ or or 4 or gt Set Software Limit or wb _ to intended Lo Hi position Cancel Software Limit Store Satellite Positions 4e Jor to the Position you want press then Input Sat No 1 69 Recall a stored position 1 SAT A Jor SAT to better position 2 Press Sat No key 69 Shift Function Recall a stored position 1 99 snit_ for 3 seconds then LED shows sh F or we lto better position Enter then LED shows P01 P99 Reset keep pressing for 10 seconds The actuator will retract fully and the software limits will be canceled Interruption Press to STOP the Motor Lock key protection press Lock Enter to lock the positioner and again to unlock it P11 Display Description Standby mode Eo l D l mmi Pulse 000 Error message no feedback from sensor or reach to hardware limits Satellite position 01 99 Enter Limit Setting mode L o a Cancel software limits Pulse 1000 dot means 1k L _ Reach to software low limit Satellite position in M Reach to software high limit storing process aL Re Calculation adjust shift function LI TI Lock key protection l l 1 Setting software high limit E E Flashy display after successful l Specification resetting the positioner Setting
4. he DiSEqC is a trademark of EUTELSAT 2 Optional Remote Control v s Receiver Do you need the optional remote control It is upon your receiver and how many Positions you want Please check the following table Receiver Type Remote Control Positions Note DiSEqC 1 2 Not Necessary 99 Fully controlled by receiver Yes Optional 99 Controlled by receiver or Optional remote control DiSEqC 1 0 No 4 Controlled by receiver Yes Optional 99 Controlled by receiver or Optional remote control No DiSEqC Yes Necessary 99 Just like stand alone Positioner Remote Control Optional for Receiver power On Off RESET Without DisEqC vata n Sat No keys Lock unlock the positioner 0 9 Cancel the inter Key Previous command For South Hemisphere The East West buttons should be exchanged Store a Satellite Position Set software east west limits Manually adjust direction to East West Shift Adjust all the Stored satellite positions P1 ee Basic Operation Front View Manual Buttons lt CESS LED East West 3 Digit LED Display 1K Indicator Back View Connect to Receiver and LNB Connect to Motor Via Coaxial Cable Pulse 36V DC Output Connect to Reed Switch Sensor Manual Buttons For South Hemisphere 2 The East West buttons East West Power Should be exchanged West East Store 3 Digits LED Display 1 The total antenna position Index pulse
5. igh Low Limits 1 Drive the Actuator by Pressing East West button to the intended lowest highest Position P s For North Hemisphere the Low limit means East Limit For South Hemisphere the Low Limit means West Limit 2 Prod Limit button on the remote control The Display will show L_ _ YO hy cel Hl Ht Coa 3 Press East or West button within 5 seconds The Display will show L L or H L Press Enter button within 5 seconds Cancel the Software High Low Limits Prod the Limit button on the remote control twice the display will show L_ _ first then Flashing LoF press the Enter button within 5 seconds to cancel the limits I Store the Satellits Positions 1 Drive the Actuator or H H mount East West until the picture on the TV screen is Clear Press Store button on the remote control The Display will show C_ _ Press no buttons 1 99 the display will show C01 C99 press Enter button the display will show PO1 P99 Repeat Step 1 to 4 to set up all the satellites you prefer ak WN H E Heo P Ca LI LII P4 Recall a Satellite Position 1 Simply press Sat A or satv button to browse OR 2 Input specific position number 1 99 on the remote control and press Enter butto
6. in and again please replace the Reed Sensor to check if the Sensor is stable 3 Restore Factory Default Reset The symbols mean Electrical Limits which have been Set If you want to cancel this setting use the Limit Off Function from the receiver And set the software limit again Make sure there is no short circuit of the wire connection Check if the Antenna is blocked by anything Make sure the Motor works well Some times a Malfunction Motor can cause higher current Maybe the Antenna is too heavy Please try to use our high power version Er2 Message No Pulses Er3 Er4 Message Internal Error Only the LED lights on and the Positioner doesn t work No response Turn Off Automatically Cant t be Turned off by Optional Remote Control or Manual Power button e Re check the wire connection Make sure the actuator is not stopped by Mechanical Limit Check if the Reed Switch Sensor is broken Check if the Motor is broken Reset the positioner Unplug the AC Power Cord from the AC outlet Wait for more than 10 seconds then re plug This problem might be caused by the unstable AC power In order to protect the stored data the Positioner will lock itself under this situation A voltage regulator might help The Display will be turned off while LNB power is off If the LNB power of receiver is switched on the positioner Can t be turned off lt Quick Table for Option
7. n Within 10 seconds the positioner will drive the actuator to the intended position p s If the position has not been stored yet the positioner will ignore this command Re calculate Adjust Shift Function If only one satellite position is not correct drive the dish to right position and store this position again If all the satellite positions are not correct then use the this function to correct 1 Recall one Satellite stored in the positioner The Display will show PXX for example P03 for 1 second and then the motor will start moving 2 After arrived keep pressing the shift button for 3 seconds the display will show Sh F and flash 3 Drive the actuator East West until the picture on the TV is clear The display will show the sensor count for example 99 9 and flash Press the Enter button during the display is flashing the display will show PXX again for example P03 All positions are shofted to right angle again The following is an example Sat dag 0 10E 20F 30E Sat Angle 0 10E 20E 30E t to l n SatelliteNo POL P02 P03 Satellite No P01 Po2 P03 P5 ock Key Protection LOCK mode is a feature that avoids any trigger on the remote control without purpose or in error 1 To enter LOCK MODE press Lock key on remote control and then press Enter button in 2 3 seconds to lock the positioner The display will sho
8. nly P01 P04 can be used C Recall a Satellite Position Change the DiSEqC 1 0 setting of the channels The positioner will drive the dish to the right Satellites while you change the channel The Display will show P01 P04 Restore Factory Default Reset This function will clear all date in the Positioner includes High Low Limits Satellite Positions etc Unplug from the AC outlet Press the Power button on the top of the positioner and re plug to the AC outlet Keep pressing the power button for 3 seconds The Display will show 10 9 1 then reset the system To stop the Reset process unplug from the AC outlet before counting to 1 P9 Troubleshooting Symptoms Check points Can t work with DiSEqC 1 0 Receiver Make sure position no 1 to 4 are stored 2 After receive DiSEqC 1 2 commands the DiSEqC 1 0 Commands will be ignored Please operate the Positioner by DiSEqC 1 2 receiver which is much better for motorization system Can t move to count less Than 0 or more than 999 The Stored Positions are not Correct The LED shows l or l and can t move more Er1 Message Over Current Or System shut dow The total position index of this Positioner is 2000 0 1999 which is enough for most of the application Use Goto Position 0 Function to solve 1 Try to use the Re calculate Adjust Shift function To correct the position first 2 If it happens aga
9. o 4 positions Position 1 2 3 4 LNB 1 2 3 4 ins A e f b The table is for your reference only The operation might be different for different receivers For example some receivers call position 1 4 as LNB1 2 3 4 or DiSEqC A B C D Please refer to the manual of your receivers 2 In order to avoid confusion the positioner will ignore the DiSEqC 1 0 commands after receive the DiSEqC 1 2 commands It can recognize the DiSEqC 1 0 commands again after unplug from AC for more than 5 seconds 3 The optional Remote Control is not necessary for DiSEqC 1 0 receivers However the optional Remote Control is strongly recommended for the following reasons 1 Easier Operation 2 More positions from 4 to 99 The following is the operation without remote control If you have the optional remote Control please refer to chapter For any Receiver Store the Satellite Positions Operate via the 3 Manual buttons 1 Drive the Actuator East West via the manual Manual Buttons East West until the picture on the TV screen Dist cf Is clear 2 Press the Power Store button for 5 seconds O O The LED will show C01 lt gt 3 Press Up Down buttons to choose the sat No you want to store C01 C99 4 Press Store button for confirmation within 3 yee West East UP Had seconds the LED will show P01 P99 Repeat Step 1 to 3 to set up all the satellites you prefer However for DiSEqC 1 0 Receivers o
10. r example P03 The position PXX is shift to a new position Sat Angle 0 10E 20F 30E Sat Angle 0 10E 20E 30E I l I l l I I l t t t t i t SatelliteNo POL P02 P03 Satellite No PO1 P02 P03 Go to the mechanical Position 0 Operate by Receiver only 1 Before using this function please make sure the mechanical limit switches of The actuator or H H mount are well adjusted in order to avoid any damage or injury 2 Send reset or Goto 0 command from the receiver The positioner will drive the motor toward East If the motor goes to the wrong direction just reverse the 2 wires Connecting currently to M1 amp M2 on the positioner The position index on the LED Display will be decreased until the motor stops due to the mechanical limit switch Then the Display will show Er2 first then 000 which indicates the mechanical 0 Position of the Actuator Restore Factory Default Reset This function will clear all data in the Positioner includes High Low Limits Satellite Positions etc Unplug from the AC outlet Press the Power button on the top of the positioner and re plug to the AC outlet Keep pressing the Power button for 3 seconds The Display will show 10 9 1 then reset the system To stop the Reset process Unplug from the AC outlet before counting to 1 P8 For DiSEqC 1 0 Receiver 1 For DiSEqC 1 0 Receivers they can control up t
11. software low limit Input Voltage Output Voltage Maximum Current Power Consumption Position Memories Protocol Remote Control Operating Temperature Storage Temperature Dimensions WxHxD Weight 220 240VAC 50Hz 110VAC 60Hz Available 13 18 VDC F Type via Coaxial Cable 13 18 VDC F Type According to the Input 36VDC via Motor Cable 5VDC Optional for Optical Sensor 2 2A 3 5A High Power Version Standby 5W Max 7OW 100W High Power Version 99 4 DiSEqC 1 2 1 0 IR Optional 5 Cto 40 C 41 F to 104 F 20 Cto 60 C 4 F to 140 F 230x70x158 mm3 Net 270x76x190 mm3 Gross 1 2Kg Net 1 3Kg Gross 0 3Kg for High Power version All Specification might be changed without prior notice PN9211 1 P12
12. sphere West Limit East Limit Cancel the Software High Low Limits After sending the command from the DiSEqC 1 2 receiver the Display of the positioner will show LoF Stor the Satellite Positions 1 Drive the Actuator East West until the picture on the TV screen is clear Choose a sat no 1 99 and then send Store command from the receiver 3 The Display will show C01 C99 then show P01 P99 Repeat Step 1 to 3 to set up all the satellites you prefer Recall a Satellite Position Change the satellite no from the receiver the positioner will drive the actuator to the intended positon However if the position has not been stored yet the positioner will ignore the command Note If the Channels and Satellites are well preset on the receiver it will drive the actuator to the right position while user changes the Channels After arriving the right position the Display will show the Satellite no as P01 P99 P7 Re calculate Adjust Shift Function 1 Recall one Satellite position stored in the positioner The Display will show PXX for example P03 for 1 second and then the motor will start moving 2 After the motor moves drive the actuator East West until the picture on the TV for this Satellite is clear for P03 3 Send Shift command or re calculate from the DiSEqC 1 2 receiver 4 After setting successfully the Display will show PXX again fo
13. w Loc after blinking and all the other functions cannot be Triggered except power on off and DiSEqC commands form receiver 2 To unlock press Lock key with following Enter button again to unlock the Positioner Restore Factory Default Reset This function will clear all data in the Positioner includes High Low Limits Satellite Positions etc 1 Unplug from the AC outlet Press the Power button on the top of the Positioner and re plug to the AC outlet Keep pressing the Power button For 3 seconds The Display will show 10 9 1 then reset the system To stop the Reset process unplug from the AC outlet before counting to 1 OR 2 Keep pressing the Reset button on the remote control until the positioner finishes counting down from 10 to 1 To stop the Reset process simply stop pressing the Reset button before the positioner counts down to 1 If reset has been successfully completed it will show on the LED After 2 seconds it shows 000 count number 1000 P6 For DiSEqC 1 2 Receiver The denomination of some commands might be different but similar Please refer to the manual of the Receiver Set the Software High Low Limits After sending the commands from the DiSEqC 1 2 receiver the Display of the positioner will show as below L Low Limit L High Limit Low Limit High Limit North Hemisphere East Limit West Limit South Hemi