Home
BC-2000 Digital Keypad
Contents
1. Press factory default setting Resetting To Factory Default Setting To revert all settings to the factory default values then the Non Volatile Memory Eeprom must be reset 12 Reset Non Volatile Memory by switching of the power and placing the jumper connector onto the pins 1 amp 2 as per figure 2 After switching power on remove jumper the BC 2000 will give a beep and is now reset to factory default values Changing User Password Code The factory default setting for each user password code 1234 this can be modified so that each user has a unique individual 4 digit code Press read user card user passoword new password it re enter new password Using Password Code to release the door Press user passoword 13 Technical Specification DC Supply Voltage Current Consumption Door Relay Alarm output load Tamper Protection Codes Keypad Card Types Induction Distance Wiring Connections Memory Operating Temperature Keypad Housing Dimensions Weight Low voltage input 12 10 Vdc unregulated 100mA quiescent maximum 5Amp 12Vdc 150mA pull current Negative loop normally closed 1 Master 1000 cards and 1000 codes 12 keys 3 LED status indicators EM or EM compatible 5 80cm Electric lock Remote door control Door open detection External door bell External Alarm Non volatile eeprom memory 0 C to 60 C 32 F to 140 F M
2. BC 2000 Digital Keypad CONTENTS Page MMOOOCIOM ccasatowaaeevesxsveescsce anna A AE 3 Product Specifications uaaaaaa aaa ee eeeees 4 Intramural Interface Circuit cc cece eee 5 Mounting amp PCB Diagram s 2112211 6 Wiring Diagram anasiasnoti tiki ALE GE r Engineer Programming Information and Notes 9 Changing Master amp User Codes 9 Adding User Codes amp CardS 10 Delete User Card or CardS 10 User Operation Mode a 111111 10 setting Door Relay Strike 11 Setting Alarm Signal Output Time 11 setting Door Open Detection 11 setting Security Arrangement 12 Resetting Non Volatile Memory 12 Changing User Password Code 13 Using Password Code to release the door 13 Technical Specifications cc eeeeee eee ee eee 14 Package Listing cccceeeeeeeeeeeeeeeeeeeeeeeeees 15 introduction The BC 2000 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary timed or latching dry contact closure All programming is done through the keypad Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure The BC 2000 can store 1000 prox cards and user 4 digit codes Each 4 di
3. etal 128mm x 82mm x 28mm 900g 14 Package Listing Name Model no Quantity Remark l Used for front Screws saa Pastern Stopper P 6mmx27 mm 4 Used for fixing ZEN P 3 5mmx27 mm 4 Used for fixing Screws 15
4. git code has 10 000 possible combinations The unit has one relay with 5 Amp contacts 1 Programmable Functions Relay latching or momentary Relay activate independently or together Change Codes 1 master 1000 users amp prox cards Door open detection Programmable Timers Door relay time 00 99 seconds Door open detection 00 99 seconds Alarm time 00 99 minutes Wiring Connections Electric lock External bell External Push Switch Magnetic Contacts Alarm Keypad 12 keys Programming memory Non volatile Eeprom memory IMPORTANT INFORAMTION There are no user serviceable parts contained within the BC 2000 access control keypad If holes are to be drilled before mounting onto a wall check for hidden cables and or pipes before drilling Use safety goggles when drilling or hammering in cable clips Every effort has been made to provide accurate information however slight variations can occur We also reserve the right to make changes for product improvement at any time NOTE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THE BC 2000 Intramural Interface Circuit 1 Alarm output interface See Figure 1 2 Electric lock interface See Figure 2 NC gt ALARM gt NO gt Q EDA z RELAY L COM gt GND Figure 1 Figure 2 1 Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head
5. is common to all users 10 Press 3 valid card only Press 3 valid card and password Press 3 valid card or password Setting Door Relay Strike Time The door relay output can be operated as either normally opened or normally closed a maximum current of 10 ampere can pass through the relay If used as normally opened or 5 ampere if normally closed The door relay time can be set from O seconds to a maximum of 99 seconds The factory default setting is 6 seconds and can be changed through the keypad Press 4 new time from 00 99 seconds Setting Alarm Signal Output Time Press 5 new time from 00 99 minutes Door Open Detection Press 6 00 to disable this function factory setting Press 6 01 to enable this function In order for this feature to work door contacts must be connected There are 2 programming functions that work together in this mode 11 a If door not closed after opening keypad buzzer sounds b If door forced open keypad buzzer sounds and sends alarm signal Arrangement There are two levels of keypad security available for the BC 2000 Press to read 10 invalid cards or valid cards then enter 4 wrong passwords in succession the keypad is locked for 10 minutes Press I to read 10 invalid cards or valid cards then enter 4 wrong passwords in succession the keypad activates and alarm signal To disable this feature
6. screws 2 When wiring has been completed attach the front cover to the rear plate 123 NVM Reset Pin J3 Wiring Cable Hamess Figure 3 Figure 4 The front cover can be permanently secured by using the short screw supplied BC 2000 Printed Circuit Board 1 Unplug the cable harness and connect the necessary cables See Figure 5 2 Tape any wires that are unused 3 Plug the cable harness See Figure 5 4 Attach the front cover See Figure 3 Terminal Wire Connector 1 Function 10 Beli White Bell Push Button 9 Bell2 White Bell Push Button 8 12V Red 12Vdc Positive Regulated Power Input 7 GND Black Negative Regulated Power Input 6 COM Orange Door Strike Relay Com 5 NO Blue Door Strike Relay N O 4 NC Green Door Strike Relay N C 3 D IN Brown To Door Contact Then To Door In 2 OPEN Yellow To Door Remote Control Button Then Negative ALARM Grey Alarm DO NOT PLUG ADAPTOR OUR TRANSFORMER INTO MAINS UNTIL ALL WIRING HAS BEEN COMPLETED AND THE FRONT COVER SECURED Wiring Diagram Electronic Door Release Holder Hookup NN 12VDC POWER SUPPLY WHITE j N RED w BLACK 6 ORANGE OBE 4 GREEN AA 3 BROW o o 2 YELLOW o 1 GREY Figure 5 1 After all wiring is complete and the unit face plate is attached to the back plate apply 12Vdc power to the unit Accept LED the yellow LED flashing Engineer Progqramminc To en
7. ter programming mode Press within 5 seconds Ready the green LED and Accept LED illuminated Open LED flashing Note Press to save changes and exit engineer programming when all programming has been completed otherwise changes will not be saved Changing Master amp User Codes In engineer programming mode To change Master code Press 0 i E Upon acceptance Open LED illuminates and stops flashing Press after changing the master code otherwise unit will disregard the new code and revert back to the factory default code Note the master code must be 4 8 digit number 9 Adding User Codes amp Cards To Add User cards amp codes Press 1 read card E Note the user identification must be 3 digit number if adding more than 1 card read the next card alter inputting the 3 digit code for the previous card when you have finished adding all cards press the 4 key 1 card must be 000 up to 999 Then the BC 2000 control station added a user card it was auto added a user code with 1234 Delete User Card or Cards There are 3 options to delete a user card or cards in engineering mode a Press 2 0000 to delete all user cards b Press 2 Read card to delete individual user card c Press 22 to delete individual user card User Operation Mode There are 3 different options for user operation mode card only card and password valid code The optioned used
Download Pdf Manuals
Related Search
Related Contents
MANUALE DI ISTRUZIONI 取扱い説明/注意事項 bedienungsanleitung dream™ hörsystem-familie ESA 31 USER MANUAL - Electro Systems Associates SERVICE MANUAL StarTech.com 15 ft IEEE-1394 Firewire Cable 6-6 M/M Allegato - Comune di Cellino San Marco Timex Ironman Race Trainer Pro HRM User Guide Page 1 SOFTWARE ELITE V2 User manual Version 06/10 Copyright © All rights reserved.