Home

NY-P6000

image

Contents

1. COOLPIX P6000_ Microscope Adapter User s Manual Microscopic documentation with the Nikon CoolPixP6000 and a microscope adapter NY P6000 Please refer to this manual for installation and camera settings nversion C mount Main Unit Conversio Built in l Ring adapter NY P6000 60111 i Connect A Relay lens Fits with eyepiecep30mm C mount Installing adapter First remove lens ring as shown at right Rotate counterclockwise Screw camera into adapter to install Installation to microscope on next page E 30mm conversion ring Insert adapter all the way down the ring It should fit just right bottom will be lined E C mount adapter First screw C mount adapter into microscope s C mount Second insert main unit with p30mm conversion ring into C mount adapter and secure with screw on the side no gap admitted Installing to Microscope Installing to Eyepiece Insert adapter to eyepiece tube remove eyepiece first If tube s inside diameter is 930mm first install conversion ring to main unit then slide it into eyepiece If tube s inside diameter is 23 2mm insert main unit directly Adapter would start rotate when diopter adjusting ring is attached to eyepiece In such case please insert the adapter after turning diopter adjusting ring to either end CC Nikon F phototube Insert only main unit to Nikon F phototube Recent Nikon t
2. U2 Once registered you can shoot with the same setting by just switching to this mode Press MENU BUTTON Use the multi selector to choose SAVE USER SETTING and press OK Other setting Please refer to User s Manual of P6000 e White Balance e e Manually adjust white balance according to light source Set it manually when you cannot reproduce color of subject precisely because of the light source User s Manual P136 e Picture Control e e Monochrome Vivid etc This is setting for image color User s Manual P129 Image Size You can choose the size pixel count for the picture recorded Small image sizes are suitable for pictures that will be distributed by E mail or used in web pages Picture shot at large sizes requires more memory and are suitable for printing but the number of shots that can be taken will be fewer User s Manual P126 e Auto off e If no operations are performed for the selected length of time the monitor will turn off and the camera will enter standby mode When AC adapter is connected 30miniute is selected automatically User s Manual P126 e Date Imprint e Date and time of recording can be imprinted on pictures User s Manual P165 E Other thing you can do with Coolpix P6000 Connect to TV monitor MH Using accessory video cable P6000 can be connected to TV monitor and MIMIN output real time images It is easier to focus with large display Also observation with ma
3. ing command dial to the left rotate command dail to left while pressing MF buttons e Rotate Zoom control to T right Zoom up until there will be no vignette e Rotate COMMAND DIAL while pressing FUNCTION BUTTON to set ISO sensitivity ISO sensitivity equals to camera s basic sensitivity Higher the value more you will be able to capture images even in darkness However when ISO is set higher than 800 noise starts to appear therefore please set low level as long as there is no shortage of light e Press EXPOSURE COMPENSATION and select F number aperture for setting e When F number aperture is set at its lowest level press EXPOSURE COMPENSATION once again and select SHUTTER SPEED for setting e Take a picture for test If image is too bright on the preview try shortening the shutter speed if it is too dark try lengthening the shutter speed Brightness of image depends on following 3 criteria Please refer when using manual setting High ISO e e e Low Bright EEE i Aperture F ss igh Shutter speed e e e Short e When you have wireless remote control ML L3 press SELF TIMER and select REMOTE CONTROL and press OK self timer e Using wireless remote or shutter release start taking picture once setting is done i gt Press the Play button The last picture shot will be displayed in full frame playback mode e Register the setting in mode dial U1 or
4. ny people can be possible Auto Bracketing It enables you to capture image with varied exposure in a single shot Use in situation in which it is difficult to guess the correct exposure co gt H as apap I M HH Hi j i 7 j O w Base Pic Active D lighting It reduces over exposure and under exposure Installing ocular micrometer sold separately Ocular micrometer of size 21mm can be installed into NY P6000 Turn the tip of adapter counter clockwise to remove bracket for micrometer Put micrometer on the bracket with printed surface facing down then reinstall to adapter body Printed surface facing down Ocular micrometer Micrometer designed for digital camera adapter S11 CF 10mm 100split pitch 0 4mm This special micrometer for digital camera adapter omitted the numbers entirely and moved scale to the periphery for clearer view
5. rinocular microscopes are usually equipped with V T phototube or F phototube In old model Optiphot Biophot SMZ 2T trinocular are applicable If microscope is equipped with 35mm camera or Polaroid system it is usually same as old model XSMZ 10 require optional sleeve X Adapter would start to rotate when diopter adjusting ring is attached to eyepiece In such case please insert the adapter after turning diopter adjusting ring to either end C mount C mount is usually for installing CCD camera which has become trendy nowadays C mount has male screw of outer diameter 25 4mm First install C mount adapter into microscope s C mount Second insert main unit with 30mm conversion ring into C mount adapter and secure with screw on the side only direct 1 0x C mount is compatible C mount with lens inside should not be used Olympus PT phototube PT phototube has outer diameter of p38mm with curving thread at the top U SPT SZ PT phototubes are these standards When 35mm camera or Polaroid system are already installed it NY BH is usually PT phototube It requires fixation sleeve NY BH option to secure adapter to microscope JIS phototube JIS standard of outer diameter 025mm and inner diameter 23 2mm Old models of Olympus microscope usually employed this standard It requires fixation sleeve NY JIS option to secure adapter to microscope Able to connect without NY JIS however the image may come o
6. ut blurry Camera Setting e e Camera setting for capturing quality image WE Main features Wireless Remote Manual focus botton exposure compensation i i button 3 up down lett right X Please refer to camera s user s manual for initial setting and basic operation O Easy settings This is easy semi auto mode e Rotate the MODE DIAL to SCENE e Holding down the FUNCTION BUTTON and rotate command dial to LANDSCAPE Select and press OK e Rotate Zoom control to T right Zoom up until there will be no vignette e Try focus using focus handle of microscope while watching camera s LCD viewer There is difference in focus level between the image captured by microscope eyepiece and the image captured by a digital camera Please make sure to focus using focus handle of microscope while watching camera s LCD viewer e Press shutter release or remote shutter to capture the image gt Press the Play button The last picture shot will be displayed in full frame playback mode e Press d xPosuRe COMPENSATION to alter exposure Press the multi select A or vV to adjust exposure O Manual Setting If you are unsatisfied with quality of image captured by easy setting please try manual setting e Rotate the MODE DIAL to M manual e Press FOCUS MODE to display focus menu Use the multi selector to choose MF and press OK e Focus to INFINITE while pressing MF BUTTON and rotat

Download Pdf Manuals

image

Related Search

NY P6000 nie p6000

Related Contents

MANUAL DEL USUARIO  ALCー2 シリ ヂズ~ ~~~~~ ~~~ 取扱説明書  InSet and 1.5 - Amazon Web Services  Makita XT406 Use and Care Manual  Samsung SPP-R200 Printer User Manual  L2EVSE30 - by Legrand    Microwave Oven  Fiche 1 - Deroche  ppS® Flow+ ppS® Flow+ ppS® Flow+ ppS® Flow+  

Copyright © All rights reserved.
Failed to retrieve file