User Manual - H and R Healthcare
Contents
1. E E 8 Emergency CPR 2 5 0 9 Cleaning cameimnmanadtageees 9 Routine Matte AN CS ey iss 9 10 Returns for 11 11 Product Specifications 12 DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS lt i otk c UL us 1 0 Indications Attention Please read enclosed document thoroughly Medical equipment with respect to electric shock fire and mechanical hazards only in accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 Declaration of Conformity to Medical Device Directive International Electronics Approval Do not immerse power unit in liquid or spray liquids directly on power unit Protective Ground Wire Type BF Equipment Indications This alternating pressure system with low air loss is designed to treat and prevent wounds by facilitating blood circulation and decreasing pressure of each tissue s contact area Always consult a physician or health professional before using this mattr
2. 3 IMPORTANT TUCKING THE SHEET IN TOO TIGHTLY REDUCES THE EFFECTIVENESS OF THE SYSTEM 8 0 Patient Transfer and Transport Transfer It is recommended to have the mattress system in firm mode during transfer Make sure the bed is secured before proceeding Transport In the event of a patient transport two options are available 1 Detach the mattress air hose couplers from the power unit s quick release couplers and connect the two air hose couplers together to retain air in the mattress The mattress will stay inflated for approximately 2 hours depending on the patient s weight 2 Unplug the power unit s power cord from the wall outlet and the mattress should stay inflated for approximately 40 50 minutes This mattress system also has a safety foam base underneath the air cells to support the patient for a short period of time in case of deflation To resume normal operation please follow 7 0 Program Settings DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 9 0 Emergency CPR Deflation In case of emergency pull hard to remove the mattress CPR latch for emergency deflation and turn off the power unit by pressing the power mute button on the control panel at the same time The mattress will deflate from the weight of the patient To resume normal operation simply reinsert the CPR latch securely press the power mute button again and reset the patient weight 10 0 Cleaning
3. in serious patient injury 2 DO disassemble the power unit if you are not a qualified technician Please contact H amp R Healthcare for all service 3 This product is NOT AP APG protected 4 t is recommended that the patient be repositioned periodically while using this mattress 5 Incorrect battery replacement may result in risk of explosion Replace only with same or equivalent battery type recommended by the manufacturer 6 If the equipment needs maintenance contact H amp R Healthcare as soon as possible For equipment that is no longer functional make sure to follow national and or state requirements for disposal of the unit CAUTION ENSURE THAT THERE ARE NO PROTRUDING ECTS SHARP POINTS OR BED SPRINGS UNDER THE MATTRESS AS THESE COULD PUNCTURE THE AIR CELLS 4 0 System Package Power Unit Package Power Unit x 1 Power Cord x 1 e Operational Manual x 1 Mattress Package e Mattress replacement unit with coverlet x 1 The air mattress operates at a max of 100 F DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 5 0 Features Control Panel Features Power LED The green power LED will light when the main power rocker switch on the right side panel is turned on Pressure monitoring LED Power unit features an integrated pressure sensor which monitors the mattress internal pressure to ensure maximum pressure relief LED indicates
4. the bed frame with the logo at foot end Secure the mattress at each side using anchor straps Ensure that the anchor straps do not interfere with any moving parts of the bed frame before proceeding to the next step 3 Secure the power unit onto the foot board using hanging hooks 4 Firmly connect the air hose couplers to the couplers on the power unit DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 272 5 Plug the power unit into an electrical outlet and turn on the main power rocker switch on the right side of the power unit 6 Press and turn the lockable patient weight knob on the power unit s control panel to maximum setting to shorten the initial inflation time if needed 7 Wait approximately 15 minutes for the mattress to inflate fully 7 0 Program Settings 1 Place the patient in the center of the mattress Adjust the mattress internal pressure according to the patient weight by using the lockable patient weight knob on the control panel of the power unit If the mattress is too soft or too firm increase or decrease the mattress internal pressure one increment at a time and wait for the system to stabilize before making another change Continue this process until comfort is achieved 2 Caregivers should always perform a hand check by placing their hands underneath patient s pelvis area to check if there is sufficient air support to ensure the patient is not bottoming out
5. DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS Operation Manual H amp R Healthcare 1750 Oak Street Lakewood NJ 08701 Phone 800 801 5533 Fax 732 367 623 1 www handrhealthcare com Congratulations and thank you for purchasing this Dyno Relief Alternating Pressure System with Low Air Loss PLEASE READ THIS OPERATION MANUAL CAREFULLY BEFORE SETTING UP AND USING THE DEVICE Pay special attention to the warnings and other safety information Use of genuine manufacturer components is essential for optimal performance If you do not fully understand all the instructions safety precautions and warnings do not use this device If you have any questions or concerns please contact H amp R Healthcare at 800 801 5533 DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 2 Section Table of Description Page TIC AGLONS 4 Safety cnctsavtecadaustncn de cececcusen 4 9 5 6 Mattress Power Unit 0 40 lt 0 0 7 8 8 Patient Transfer and 0
6. Instruction Air mattress and power unit must be cleaned thoroughly between patients to avoid cross contamination The following is a suggested guideline Be sure to follow local infection control policies Regular cleaning can be performed at bedside with disinfectant followed by drying with a clean dry cloth Use only mild detergents to clean the coverlet and the mattress Any appropriate NON PHENOLIC cleaning agent may be used for heavy soiling from urine blood or other bodily fluids Please ensure that air mattress and coverlet are completely dry before letting the patient lie on the surface again Do not use electric or tumble dryers Do not iron WARNING Always unplug the power unit before cleaning Routine cleaning of power unit can be done by wiping down with damp cloth using disinfectant or mild detergent Never spray liquids directly on the unit itself 11 0 Routine Maintenance Remove air filter from the rear panel of the power unit by opening up the filter cap Inspect the filter for dirt or dust and clean it with mild soap and water Reinsert the dried air filter after cleaning and ensure that the cap is secure If replacement is needed contact H amp R Healthcare Only disinfected and dry systems should be stored Disconnect the air hoses from the power unit Roll up the mattress starting from the head end and working down toward the foot end Use the straps to secure it DYNO RELIEF ALTERNATI
7. NG PRESSURE SYSTEM WITH LOW AIR LOSS 12 0 Troubleshooting Problem Inspection Procedure Possible Solutions 1 Power unit is not working Check if power cord is firmly plugged into both the control unit and the electrical outlet Secure power cord into control unit and or electrical outlet Check if the power switch is in the ON position Turn power switch to ON position Check if power surge has shut down the power unit A power surge may overload the circuitry temporarily Turn the unit off and check the fuse for damage Turn the unit on again with normal procedure Make sure there is no power failure Power unit does not respond to possible solutions Please contact amp R Healthcare for assistance 2 Low Pressure alert does not turn off after 30 seconds after the system is turned on Possible control failure Please contact amp R Healthcare for assistance 3 Power unit is working but mattress replacement is not inflating and or Bottoming out is occurring and or Patient leaves a deep indentation at the contact area which does not return back to its original shape Verify that CPR latch is properly inserted Insert CPR latch securely Check if mattress air hose couplers are properly connected to power unit s quick release couplers Secure air hose couplers firmly into place Verify that patient weight sett
8. been attempted by any person or agency not authorized by H amp R Healthcare or if in the sole option of H amp R Healthcare the system shows evidence of tampering abnormal or unreasonable abuse negligence accident or operation without cover routine maintenance such as cleaning adjustment lubrications and updating of equipment or parts If in the sole opinion of H amp R Healthcare the damage is not covered under this warranty the purchaser will be responsible for labor and parts costs The warranty stated above is the only warranty made and is in lieu of all other warranties whether expressed or implied H amp R Healthcare nor any of its agents shall be held liable for consequential or incidental damages of any kind 15 0 Product Specifications Mattress Dimension MSR204 80 84 x 37 10 5 Number of Air Cells 20 Air Cells Power Control Unit Dimension SR362 11 5 x 8 5 x 4 5 DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 11 Integrated Foam 2 Material Power Unit ABS fire retardant UL Mattress Cell 100 nylon with TPU lamination Coverlet 100 nylon with PU backing Power Input AC100 120V 60Hz AC220 240 V 50Hz Power Consumption Normal Operation Max 1 0A Power Control Unit Weight 5 5 Ibs Fuse Rating T1A 250V Electrical Classification Class 1 Type BF do not immerse power unit in any liquid or spray any liq
9. ess system Contraindications This device is not indicated for treatment of certain patient conditions such as fracture of unstable vertebrae and illness of unstable vertebrae Always consult a physician or health professional before using this device 2 0 Safety Precautions 1 To ensure proper operation please inspect and verify that all parts are set up properly and are anchored securely Do not place anything on top of the power unit Make sure power cord is underneath bed frame and does not pose a hazard 2 It is recommended to limit bed linens to a single layer in order to allow moisture to escape efficiently through the coverlet Breathable incontinent pads are recommended for use with this mattress system 3 Avoid using this device near open flames lighters or cigarettes Flammability hazard exists This device draws air from the surrounding environment Thus cigarette smoking may damage internal components 4 This system should be disinfected thoroughly between patients to avoid cross contamination 5 Verify that patient weight does not exceed the weight capacity DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS of the bed frame bed rails or this mattress system 3 0 Warnings 1 Use this mattress with proper side rails to ensure that the gap between the side rail and the top of the mattress is not large enough to pose risk of head or neck entrapment Failure to do so could result
10. ing is correct Increase or decrease weight setting until appropriate pressure is reached Inspect air filter for dust Clean or replace air filter Lift mattress coverlet up to check if air cells are connected correctly Make sure all air cells are properly linked to air supply DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS 10 Lift mattress coverlet up Check and adjust air to check if air tubes are tubes positions kinked or obstructed or cracked Check if air cells are cut Please contact H amp R Healthcare for assistance 4 Patient s wounds are not responding to Contact your physician and or nursing service pressure relief reddening immediately of skin 13 0 Returns for regard for the restrictions specified i in the instructions which accompany Service the system This warranty does not Service and repair must be performed by an H amp R Healthcare authorized technician or representative Please contact H amp R Healthcare at 800 801 5533 14 0 Warranty H amp R Healthcare warrants this product against manufacturer defects for one year from the date of placement Please inspect this product upon purchase notify H amp R Healthcare if there is any damage or missing parts Warranty coverage will not be extended to any product on which the production lot number has been removed or defaced on which repair has
11. that the system is monitoring the mattress internal pressure while the compressor is inflating Lockable Patient Weight Knob Patient Weight Knob is used to adjust the pressure of the mattress according to patient weight Simply press and turn the knob to adj ust the pressure setting if the mattress is too soft or firm to suit each patient s needs Caregivers should always perform a hand check by placing their hands underneath the patient s pelvis area to check if there is sufficient air support to ensure that the patient is not bottoming out DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS Right Side Panel Features Rocker Switch 1 Power unit s main power switch Couplers 2 Quick release female couplers are used to secure mattress air hoses to power unit Power Receptacle 3 Insert power cord firmly into receptacle Rear Panel Features 4 Convenient Handle 1 The handle provides additional gripping surface for user to carry the power unit Hanging Hooks 2 Hanging hooks are designed to hang the power unit on almost any foot board Fuse 3 Fuse Holder Air Filter and Cap 4 H amp R Healthcare recommends that the filter be kept clean to ensure optimal performance of the power unit 6 0 Mattress and Power Unit Installations 1 Remove existing mattress from bed frame 2 Place H amp R Healthcare mattress replacement on
12. uids directly on the power unit This system is not AP APG Protected Continuous operation Agency Approval EN60601 1 EN60601 1 2 EN61000 3 2 EN61000 3 3 UL 60601 1 Complies with Cal Tech Bulletin 117 Electromagnetic Compatibility EN60601 1 2 1993 Maximum Weight Capacity 325 Ibs H amp R Healthcare reserves the right to change prices or design parameters and specifications without incurring any liability in connection with such modifications DYNO RELIEF ALTERNATING PRESSURE SYSTEM WITH LOW AIR LOSS
Download Pdf Manuals
Related Search
Related Contents
DeLonghi EC5 Espresso Maker User Manual SRO-250 Consulter le rapport Mitsubishi Trium Eclipse Operating Instructions Installation Manual Garage Door Sentry Coopérer et décider dans les nouveaux territoires Nextbook Premium 7 Google Play Operating Instructions 取扱説明書 品番 CF Copyright © All rights reserved.