DL-100TM485 Series User Manual
Contents
1. eae fine DL 100TM485 User Manual V1 00 9 23 DL 100TM485 Series User Manual V1 02 Mar 2015 10 23 DL 100TM485 Input Registers Number Address Function Access Data Name Comments IE IS 30001 0 03 04 Word Humidity value The response value is the result of the original elo ee meno 30002 1 03 04 Word Temperature value in degrees Celsius The response value is the result of the original Ta ee me 30003 2 03 04 Word Temperature value in degrees The response value is the result of the original Pa PM oo 365521 65520 03 04 Word Firmware version The response value is a hex value The high FFFO byte denotes major version the low byte denotes minor version 365522 65521 03 04 Long HI Module Name The response value is a hex value The high Pre IE E 365523 65522 03 04 Long LO Module Name The response value is a hex value The high ER kr byte denotes 0 the low byte denotes 50 365524 65523 03 04 Word The number of log records Pee Tees Mee moment DL 100TM485 User Manual V1 00 10 23 DL 100TM485 Series User Manual V1 02 Mar 2015 11 23 DL 100TM485 o toseconds 3 iminute 6 thour J9 Ghours 1 20 seconds 4 5minutes 7 2hours ox0A 12hours 2 30seconds 5 10 minutes 8 Ghours ox0B 1day gt Table 1 Holding Registers 365525 65524 03 04 R W Byte The high byte Module address 17248 Bit The low byte The logging mode 0 The module will stop l
2. DC 0 15 W Input Range Power Consumption Mechanical Dimensions W x Lx H 82 mm x 126 mm x55 mm Waterproof Level Installation DIN Rail Wall mount DL 100TM485 Series User Manual V1 02 Mar 2015 5 23 Operating Temperature 20 60 C 30 80 C 5 95 RH Non condensing Standard Version ARH RH FP Version 0 10 20 30 40 50 60 70 amp 90 100 Relative Humidity RH Figure 1 Maximal RHolerance at 25 C per sensor type Standard Version 40 20 0 20 40 60 80 100 Temperature C Figure 2 Maximal I tolerance per sensor type DL 100TM485 Series User Manual V1 02 Mar 2015 6 23 1 2 Function Block DL 100T485 LCM Display Humidity amp EEPROM Tempertaure Sensor 8 Bit MCU Data RS 485 Data Interface kid Power GND Regulator 1 3 Pin Assignments Bottom DL 100TM485 Series User Manual V1 02 Mar 2015 7 23 1 4 Wire Connections DL 100TM485 Series User Manual V1 02 Mar 2015 8 23 2 Modbus RTU Protocol The Modbus protocol was originally developed for Modicon controllers by Modicon Inc Detailed information can be found at http www modicon com techpubs toc7 html Visit htto www modbus org to find more valuable information The DL 1001M485 module supports the Modbus RTU protocol The communication Baud Rate is 9600bps and the parity data bits and stop bits are fixed as no parity 8 data bits and 1 stop bit The following Modbus functions are supp
3. DL 100TM485 Series User Manual DL 100TM485 DL 100TM485 W DL 100TM485P DL 100TM485P W DL 100TM485 Series User Manual V1 02 Mar 2015 1 23 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser Warning ICP DAS assumes no liability for any damage resulting from the use of this product ICP DAS reserves the right to change this manual at any time without notification The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents or other rights of third parties resulting from Its use Copyright CopyrightO 2014 ICP DAS All rights reserved Trademarks Names are used for identification purposes only and may be registered trademarks of their respective companies DL 100TM485 Series User Manual V1 02 Mar 2015 2 23 Table of Contents l FAME NOT HS AS SR a bb aa 5 11 SPECT 5 12 FINN BIOCK dd 7 Ted PIRFASSIGAMEOM IS iii 7 ME NNN 8 MP RV PONG 9 21 MODUS MAPPING TENDENS 10 gt VSOP 14 3 1 Before you use the Utility Software 14 32 DETOOTM48 9 ONE re ere ee eee ae 15 35 dis 16 4 Dowmnoda DANS Se rae ae eter aaetect a 20 d PADIS INGUIN RR 22 21 DINO NON 22 DL 100TM485 Series User Manual V1 02 Mar 2015 3 23 Introduction The DL 100TM485 DL 100TM485P D
4. L 100TM485 W DL 100TM485P W is a one channel temperature and humidity data logger module It contains a built in RS 485 communication interface and an LCD indicator to display the module ID temperature and humidity data and allows you to define the log time interval depending on your application The DL 1001M485 supports the Modbus RTU protocol Refer to Section 2 for more details We also provide software utility that can be used to retrieve log data and display it in a chart on your desktop and also allow you save the log data into an Excel format file DL 100TM485 Series User Manual V1 02 Mar 2015 4 23 1 Hardware Information 1 1 Specifications DL 100TM485 DL 100TM485P Range 20 60 C 31 176 F Precision 0 1 C Accuracy Typical 0 3 C See Figure 2 Humidity Measurement Range O 100 RH Resolution 0 1 RH Precision 0 1 RH Accuracy Typical 3 RH 207 80 RH Typical 1 8 RH 10 90 RH See Figure 1 See Figure 1 LCD Display Displayed Information Temperature Measurement Temperature C and F Humidity RH Module ID Data Logger Max Records 4088 temperature and humidity records Time Interval 10 seconds to 1 day Mode Overwrite Limitation Overwrite or stop logging when storage space is full 1 000 000 cycles Communication RS 485 non isolated 1200 115200 bps N 8 1 32 Interface Baudrate Data Format Max Modules on same bus Power 10 30 V
5. Manual V1 02 Mar 2015 14 23 3 2 DL 100TM485 Utility After launching the Utility the program interface will be displayed as shown below DL 50 100 Utility 1 0 5 File Connection Functions O Connection 15 not established Pe lt 2 e Clicking File orthe 4 icon opens a previous DL 100TM485 logging data file stored on your PC e Clicking Connection gt Connect gt RS 232 RS 485 or the icon creates a connection from the serial port g e Clicking Connection gt Disconnect or the icon disconnects the connection between the PC and the DL 100TM485 icon retrieves the logging data which is stored in the EEPROM of the DL 100TM485 module e Clicking Functions gt Get Records or the e Clicking Functions gt Configuration or the gt icon enables you to configure the DL 100TM485 module e Clicking Exit or the Q icon closes the Utility software This function is only valid when a connection has been successfully established between the PC and the DL 100TM485 module DL 100TM485 Series User Manual V1 02 Mar 2015 15 23 3 3 Configuration 1 Launch the DLUtility exe DL 50 100 Utility 1 0 9 File Connection Functions Connection is not established Connection status 2 Link with the DL 1001M485 P DL 50 100 Utility 1 0 9 File Connection Functions O Connection Is fot established ES Z2FURS 465 Connection Select the COM port nu
6. e next time power is turned on DL 100TM485 Series User Manual V1 02 Mar 2015 17 23 Data Log Tab Basic Data Log Others SOSA RX pg aa ST SJ A e lt a Cd wA 9 Y Log Functions f Advanced Log Functions Do nat A 2 3 Get the number of log records Clear Disable Set Camnmzzunmunzanunznunznanzanznannnnnnnnzet LLI II INTANT e 0 e o Von Asa PORO A Log Time Intervals e e e On this tab vou can 1 Enable Disable data logging Select the Enable Disable radio button and then click on the Set button Note The data logging will be disabled whenever the module is connected through the DLUtility Please enable the logging function before leaving the DLUtility 2 Set the Log Mode select the Mode 0 Mode 1 radio button and click on the Set button Mode 0 stops data logger when the storage space is full Mode 1 continues data logger and overwrites the old data with the new data when the storage space is full 3 Set the time interval for data logging move the slide to select the time interval and click on the Set button The available time interval can be set is 10 seconds 20 seconds 30 seconds 1 minute 5 minutes 10 minutes 30 minutes 1 Hour 2 Hours 6 Hours 12 Hours and 24 Hours 4 Read the number of data records or clear the data in the DL 100 logger DL 100TM485 Series User Manual V1 02 Mar 2015 18 23 Basic Tab Details Basic Data Log Other
7. ile EM Load Log Data E E A RATHOD CD 4100 data C Show chart L4 y manual ERA IE dataZ0150319 tet Temperature Humidity 4 FT 267 54 1267 537 1267 538 ME 26 539 1267 538 126 7 267 267 1287 1266 i TE BEN nen FED DL 100TM485 Series User Manual V1 02 Mar 2015 21 23 4 Appendix 4 1 LCD Information The LCD display information can be set from the Others tab on the Configuration dialog window as below Basic Data Log Others Temperature Offset PO s System Date Time TEN S MT WI FS a 1 3 4 5 6 fF 15 16 EN 18 19 20 21 22 23 24 25 26 21 28 29 30 31 of Today 2015 3117 p TCD Display Items 0 Module ID System Time Relative Humidity 2 C Baud Rate Degrees Fahrenheit F Degrees Celsius C Set ooo ea net DO EE DL 100TM485 Series User Manual V1 02 Mar 2015 22 23 e Module Address Indicates that the currently displayed information Is the module address 00 FF Indicates the current module address 01 in this example e Temperature Value DL 100TM485 Series User Manual V1 02 Mar 2015 23 23 D ea Indicates that the currently ICON displayed information is the temperature 2 DDD D DD D Indicates the current temperature value Indicates the temperature units e Humidity Value Indicates that the currently ud ml displayed information is the humid
8. itv e pe ela value DL 100TM485 Series User Manual V1 02 Mar 2015 24 23
9. mber Com Port Model Name and Module Address 2 digit hexadecimal number and Model Name DL 1007485 y then click the OK button Module Address 00 FFj Baud Rate 600 i bps Data Format Checksum Disable Enable DL 100TM485 Series User Manual V1 02 Mar 2015 16 23 3 Configure the DL 1001M485 P Click on the icon to enter the configuration dialog window DL 50 100 Utility 1 0 9 File Connection Functions 4 Connection is established Connection status Others Tab Basic Data Log Others LEE ET NG e e e a e stem Date amp Time LA roa WA 4 4 11 5 MT WT FO 5 1 2 3 4 5 6 7 7 8 9 10 11 12 13 14 79 15 16 Bg 18 19 20 21 22 23 24 25 26 27 28 8 LCD Display Items DE 29 30 31 Ea 7 5 a E Today 2015 3117 PE b TR Module ID System Time JE ka f Relative Humidity 2 2 ii 2015 3117 17 17 07 El Degrees Fahrenheit F Degrees Celsius C Set o a A nnnnnnnnnnunee On this tab you can 1 Set the temperature offset value move the slide to select the temperature offset value and then click on the Set button 2 Set the LCD display information check the checkboxes for those items to display on the DL 100 logger and click on the Set button 3 Read the time on the PC and set it into the DL 100 logger Click on the Set button to set the time on the PC to the DL 100 Note The time setting will be cleared th
10. ogging if the EEPROM memory is full 1 The earliest stored data record will be overwritten if the EEPROM memory is full 365526 65525 03 04 The high byte LCD display items 00 3F 06 16 OxFFF5 The low byte The logging time The allowed range is from 0 to OxOB Refer to 365527 65526 03 04 Sign The Ta byte Module baud rate 06707 The low ee The temperature offset The unit is 0 1 a in Celsius the range is ee from 12 8C 12 7C 365528 65527 03 04 Word The starting address of the logging The response value will be filled with 0x7777 OxFFF7 06 16 data record you want to read when this value is higher than the last address DL 100TM485 Series User Manual V1 02 MaPlzq 99 TM485 User Manual V1 00 42 23 11 23 DL 100TM485 365529 65528 03 04 R W Byte The numbers of logging data records The response value will be filled with 0x7777 Pm Terra oro rain 65529 03 04 R W Word The base vear and month values The response value is a hex value The high bvte 365530 OxFFF9 06 16 denotes the vear the low bvte denotes the month 365531 65530 03 04 R W Word The base day and hour values The response value is a hex value The high byte OxFFFA 06 16 denotes the day the low byte denotes the hour 365532 65531 03 04 R W Word The base minutes and seconds values The response value is a hex value The high byte OxFFFB 06 16 denotes the minutes the low byte denotes the second
11. orted Read coils status OXXXX Read discrete inputs 1XXXX Read multiple input registers 3xxxx Write single coils Write multiple coils OXXXX If the function specified in the message is not supported then the module responds as follows Error Response 00 Address 1Byte 1 247 1 Byte Function code 0x80 Exception code 1 Byte 01 lf a CRC mismatch occurs the module will not respond DL 100TM485 Series User Manual V1 02 Mar 2015 9 23 DL 100TM485 2 1 Modbus Mapping Table DL 1001M485 Modbus RTU Tables Coils Number Address Function Access Data Name Comments RES ES 00257 256 01 02 R W Bit Enables or disables the logging 0 Disabled en ons ae ee 00258 257 O1 02 R W Bit Resets the value of the log records Set this bit to on to clear the log data counter 0x101 05 15 counter to 0 value This bit will be set to 0 when cleared successfully 00259 258 01 02 R W Bit Set the page of the first log data which There are two pages of log space available in 0x102 05 15 you want to read the DL 50M and each page contains 32760 humidity and temperature data records 10260 259 01 02 Bit Reset Bit This bit only returns a value of 1 when you read 0x103 it for the first time In all other cases it alwavs returns a value of 0 10261 260 01 02 Bit The page number where the first log data O First page ed sense 10262 261 01 02 Bit The page number where the last log data 0 First page PP Teas
12. s SECC ee e 5 Firmware Version Baud Rate a 9600 l Checksum ATT DO ir it A CC CC CAC CC A CC QC CR CB A e e On this tab vou can 1 Set the module address and communication parameters Move the slide to select the module address Baud Rate Data Format and click the Set button 2 Read the real time data Check the Polling Data checkbox Except the LCD Display Items on Others tab all the configuration functions will be disabled after the Polling Data checkbox is checked 3 Read the firmware version for the DL 100 module DL 1001M485 Series User Manual V1 02 Mar 2015 19 23 3 4 Download Data DL 50 100 Utilitv 1 0 9 File Connection Functions i f pt iu y r P ka y ls a Connection 15 established Connection status 1 Click on the Get button and click on the Yes button on the pop up dialog boxes EF Load Log Data The Date Time of the fi Show chart Ms succesfulbr downloaded from the DL 100TM485 b Data receiving MAD DL 1001M485 Series User Manual V1 02 Mar 2015 20 23 2 Check the Show chart checkbox to display a line chart of download data EM Load Log Data The Date Time of the first log data Chart Line v Foint Labels None vi Display chart as 3D Show X Axis Margin L e Temperature Humidity 3 Click on the Save as file button to save the download data in a text file of extension filename csv or filename txt f
13. s 365533 65522 03 04 R W Word The current year and month values The response value is a hex value The high byte OxFFFC 06 16 denotes the current year the low byte denotes the the month 365534 65533 03 04 R W Word The current day and hour values The response value is a hex value The high byte OxFFFD 06 16 denotes the current day the low byte denotes the current hour 365535 65534 03 04 R W Word The current minute and second The response value is a hex value The high byte OxFFFE 06 16 values denotes the current minute the low byte denotes the current second DL 100TM DL 100TM485 User Manual V1 00 12 23 3 Utility Software 3 1 Before you use the Utility Software Before you use this Utility please make sure you have installed Microsoft NET Framework 4 If you haven t installed NET Framework yet please refer to section 2 for more information or refer to section 3 for more information about the installation of this Utility To download NET Framework refer http www microsoft com downloads en details aspx FamilylD 9cfb2d51 5ff4 4491 b0 1 e5 b386f32c0992 amp displaylang en You also can find the Microsoft NET Framework 4 web installer package in the following location on the enclosed CD Napdos Net_FrameWork dotNet x40 Full setup exe The Utility software is located in the following location in product CD NapdosiDL 100WUtility DL 100TM485 Series User
Download Pdf Manuals
Related Search
Related Contents
PPE MODE D`EMPLOI 2012 - Chambres d`Agriculture de Bretagne Bedienungsanleitung Nemesis-TCS 'Traction Control System Installation manual A型看板「Pita-A(ピタ・エース)」 9 消耗部品の交換方法 "取扱説明書" Reizen Analog Radio-Controlled Talking Watch SERVICE MANUAL DE EN FR IT BEDIENUNGSANLEITUNG USER MANUAL MANUEL Copyright © All rights reserved.