1. 38 10099 San Mauro T se Torino Italy 495 Rue Antoine Pinay 69740 Genas Lyon France c Vapor 18 Pol Ind El Regas tel 390112235410 fax 390112735590 tel 33478406525 fax 33478406746 08850 Gava Barcelona Espana tecnoalarmetecnoalarm com tecnoalarm france tecnoalarm com tel 34936622417 www tecnoalarm com www tecnoalarm com tecnoalarmetecnoalarm es Agence de Paris www tecnoalarm com 125 Rue Louis Roche 92230 Gennevilliers
2. Blinking quickly Arming phase of the program 10 seconds Blinking slowly Program partset On Program armed Pogram alarm LED The alarm is only signaled if the program is armed Off No alarm program Blinking Active program alarm On Stored alarm The signal of stored alarm continues until the following arming TP8 28 TP8 28 GSM Hi Tech Security Systems Tecn alarm Use of the transponder Since the LCDPROX1 console is equipped with a transponder reader it also permits arming and disarming the programs using a transponder instead of the access code The procedure is explaining below Managed programs The console permits arming disarming of the programs defined by the installer Tue 10JAN 12 ABBE Work 13 46 ABG y Q o T W w Reading of the transponder The transponder is read as soon as it is approached to the RFID field of the console When the transponder is recognized as valid the transponder LED blinks once TecnYalarm Warning The transponder is only read very close to the RFID field MENU e Arming Arming is made in three phases Arming of the program with transponder Approach the transponder to the RFID field A Verify that the blue LED blinks once a Tue 10JAN 12 A Reading of the transponder kn Na e me OO Toei B Selection of the programs to be armed oe ACCESS C Confirmation Select the program s to be arme
3. TP8 28 TP8 28 GSM Expandable serial alarm systems TUE 29 Jan 13 BEE Work 13 46 5 6 7 e mta ME TAW W a User quick guide Release 1 0 FW version 0 2 00 Control panel versions TP8 28 TP8 28 GSM Programming SW version ATA POG Update 12 2013 Language English Tecn alarm Hi Tech Security Systems Tecn alarm Hi Tech Security Systems CONFORMITY The present equipment is in compliance with the essential requirements and other relevant provisions of the R amp TTE 1999 05 EC directive The equipment is also in compliance with the standard EN 50131 1 The declaration of conformity is available on the website www tecnoalarm com The product features can be subject to change without notice Unauthorized reproduction or distribution of this manual or any portion of it on any device and in any form is prohibited The contents of this manual may be subject to change without notice TP8 28 TP8 28 GSM Hi Tech Security Systems Tecn alarm INDEX 1 1 LCD300 S 5 1 2 LCDPROX1 7 2 1 Arming 11 2 2 Disarming 11 2 3 Direct arming 12 2 4 Direct disarming 12 2 5 Arming with exclusion of the open zones 13 2 6 Hold up alarm activation 13 2 7 Panic alarm activation 14 2 8 Consultation of the stored alarms 14 2 9 Consultation of the event log 14 D TP8 28 TP8 28 GSM 3 Tecn alarm Hi Tech Security Systems 4 TP8 28 TP8 28 GSM A H
4. arming session The stored alarms are viewed until the next arming of a program As soon as any of the programs is armed the memory is automatically reset to memorize the events of the new functioning session Consultation of the stored alarms Ue Mc ee da To consult the memory press MEM If the memory is empty on the display is viewed None lf the memory contains alarms they are displayed in Viewing sequence one at a time Control panel ALARM MEM None 2 9 Consultation of the event log The control panel stores all the events regarding functioning management and alarms in its event buffer lis storage capacity is 1 500 events Once the memory is full for every new event the oldest one is overwritten Consultation of the event log Enter the access code Press MEM Press the arrow key anan ACCESS Master Viewing Events Use the arrow keys to consult the events For each event the date and hour of occurrence are stored The second line of the display shows the description of the event Press EXIT to quit the event log Tue 21 FEB 12 lWork 12 15 14 TP8 28 TP8 28 GSM Hi Tech Security Systems Tecn alarm GD TP8 28 TP8 28 GSM 15 Tecn alarm HI TECHNOLOGY amp DESIGN C Copyright 2013 Tecnoalarm s r l All rights reserved Document edited by the Technical Documentation Department Last update 12 2013 Tecn alarm Tecn alarm Tecn alarm Via Ciri
5. d Ja Mar 10 JAN 12 B Press YES to confirm and quit Cores Henig vay i Disarming of the program with transponder Disarming Approach the transponder to the RFID field Disarming is made in three phases O Verify that the blue LED blinks once Pe Mar 10JAN 12 f A Reading of the transponder transponder recognized l Work 22 00 e Remove the transponder B Selection of the programs to be disarmed ACCESS C Confirmation O Select the program s to be disarmed Key 1 l Tue 10 JAN 12 Press YES to confirm and quit Work 22 00 N B The recognition of a valid transponder automatically switches off the program alarms without entering the corresponding program number Warning The Disarming confirmation functions only if activated by the installer Confirmation of disarming blocking of hold up alarm Disarming confirmation Approach the transponder to the RFID field a The disarming confirmation is Verify that the blue LED blinks once a Mar 10 JAN 12 f transponder recognized n Work 22 00 8 made in four phases Remove the transponder A Reading of the transponder B Selection of the programs to be Select the program s to be disarmed pe disarmed ey l C Confirmation D Confirmation of disarming with Press YES to confirm and quit ra ee access code e n ee ya Tue 10JAN 12 valid user code see note Work 22 00 B If the user code is not entered during the programmed Di
6. g the code on the display is viewed Complete Complete password Password ACCESS Select the programs Master to be disarmed Disarming Confirm disarming Program 1 of the programs Tue 21 FEB 12 The programs 1 and 3 Work 12 15 are disarmed D TP8 28 TP8 28 GSM 11 Enter the access code Once the code has been entered on the display is viewed ACCESS On the display is viewed Disarming followed by the programs Tecn alarm Hi Tech Security Systems 2 3 Direct arming It is possible to simultaneously arm all the programs associated to the code Arming is made in two phases A Entering of the code B Confirmation Tue 21 FEB 12 Work 12 15 In case of error abort the process by pressing rep within 5 seconds then restart Complete Password ACCESS Master Arming Control panel OK Tue 21 FEB 12 Work 12 15 Enter the access code While entering the code on the display is viewed Complete password Once the code has been entered on the display is viewed ACCESS Arm all the programs associated to the code On the display is viewed the confirmation of arming All the programs associated to the code are armed 2 4 Direct disarming It is possible to simultaneously disarm all the programs associated to the code Disarming is made in two phases A Entering of the code B Confirmatio
7. i Tech Security Systems TecnZYalarm 1 CONSOLES 1 1 LCD300 S The LCD300 S console permits arming and disarming of the system s programs activation and deactivation of the remote controls and gives access to the programming menus of the system The console is equipped with two groups of LED the first one below the display is composed of 6 LED that provides general trouble and status signaling The second group below the keys is composed of 15 pairs of LED and views the program states and alarms Battery status yellow LED Battery OK Low battery Battery fault Power failure alarm yellow LED No alarm Active alarm Stored alarm O Trouble A yellow LED Off Notouble Active trouble Active GSM trouble Stored trouble CM Command mode 3 fa CM green LED gn an an Ga Console not in use Console in use On Tamper alarm e Mains voltage red LED ans T green LED No alarm cis i sis Off Mains voltage absent Active alarm 9 at J CE ziS e On Mains voltage present Stored alarm es ad as I i EL a Li Program status Program alarm yellow LED red LED Off Program disarmed Off No alarm Blinking quickly Arming phase Blinking Alarm active Blinking slowly Program partset On Stored alarm On Program armed Signaling LED Trouble LED The system constantly controls its funct
8. ioning Any trouble is immediately signaled In case of active trouble the LED A is blinking at the end of the alarm it is switched on permanently to signal that the alarm has been stored The stored alarm signal continues until it is cancelled with the appropriated procedure The troubles are also stored into the event buffer of the system Blinking quickly Trouble of the system s GSM module Blinking slowly General trouble of the system CM LED e The CM LED command mode is lit as soon as the user starts typing on the keys It is lit during the entire access CM time and during 10 seconds after the last keystroke When the LED is switched off the user must enter the access code again to have access to the console D TP8 28 TP8 28 GSM 5 Tecn alarm Hi Tech Security Systems wy Yellow LED Red LED Tamper alarm LED The LED signals the tamper alarms of the system The system s anti tamper protection is always active and is independent from the program status Off No tamper alarm Blinking Active tamper alarm On Stored alarm The stored alarm signal continues until it is cancelled with the appropriated procedure Battery status LED The LED signals the status of the system s battery Off Battery OK Blinking Low battery On Battery fault i e the battery is no longer able to support the system Power failure alarm LED The LED signals the failure of mains power 230V AC Off No a
9. larm mains power OK Blinking Active power failure alarm On Stored alarm The stored alarm signal continues until it is cancelled with the appropriated procedure Mains voltage LED The LED signals the presence of mains voltage 230V AC Off Mains voltage absent On Mains voltage present Program status LED The LED signal the following states of each program disarmed arming phase armed and partset During the 10 seconds arming phase of the program the corresponding LED is blinking quickly and it is possible to arm disarm other programs and exclude the open zones from the alarm detection Off Program disarmed Blinking quickly Arming phase of the program 10 seconds Blinking slowly Program partset On Program armed Program alarm LED The alarm is only signaled if the program is armed Off No alarm program Blinking Active program alarm On Stored alarm The signal of stored alarm continues until the following arming TP8 28 TP8 28 GSM Hi Tech Security Systems TecnZalarm 1 2 LCDPROX The LCDPROX1 console permits arming and disarming of the system s programs activation and deactivation of the remote controls and gives access to the programming menus of the system The console is equipped with two groups of LED the first one situated on the right of the display is composed of 7 LED which provide general trouble and status signaling The second group on the left of the keys is composed of 8 pairs
10. n Tue 21 FEB 12 Work 12 15 In case of error abort the process by pressing rep within 5 seconds then restart While entering the code on the display is viewed Complete password Enter the access code Complete Password ACCESS Master Tue 21 FEB 12 All the programs associated Work 12 15 to the code are disarmed Once the code has been entered on the display is viewed ACCESS Disarm all the programs associated to the code 12 TP8 28 TP8 28 GSM Hi Tech Security Systems Tecn alarm 2 5 Arming with exclusion of the open zones Only the enabled codes can arm a program excluding possible open zones The procedure is described considering the conventional arming which permits the selection of the programs to be armed Tue 21 FEB 12 Work 12 15 Enter the access code In case of error abort the process by pressing CED within 5 seconds then restart Complete Password ACCESS Master Arming Program 1 Open zones Window kitchen Arming Control panel OK Tue 21 FEB 12 Work 12 15 While entering the code on the display is viewed Complete password Once the code has been entered on the display is viewed ACCESS Select the programs to be armed Confirm the arming of the programs To stop signaling of the open zones and arm The programs 1 and 3 are armed and the open zones are excluded On the display is viewed Arming follo
11. of LED and views the program status Trouble Battery status yellow LED yellow LED Off Off No trouble Battery OK Blinking quickly Active trouble Blinking Low battery Blinking slowly Active GSM trouble On Battery fault On Stored trouble Power failure alarm CM Command mode Mi yellow LED green LED Console not in use Blinking Active alarm Console in use Stored alarm Mains voltage green LED On Off Mains voltage absent On Off Tamper alarm red LED No alarm Blinking slowly Active alarm Mains voltage present On Stored alarm Transponder blue LED No transponder read and recognized Blinks once Transponder read and recognized 4 Program status Program alarm yellow LED red LED Program disarmed No alarm Blinking quickly Arming phase Alarm active Blinking slowly Program partset Stored alarm On Program armed Signaling LED and icons Program status signaling The LCDPROX1 console signals the system status through Mi a a a A eon e LED and specific icons which are viewed on the right hand The icon is only viewed if the corresponding program side of the display There are two groups of icons which are is armed displayed alternately according to the operating mode The first group of icons represents the programs and Trouble and tamper icons fo
12. r each of them indicates the following states armed disarmed partset and arming phase i Low battery The second group signals trouble general alarm and tamper Tamper pa Power failure The icons are only displayed if a trouble occurs Pe FE m Warning In case of simultaneous signaling the program A Rage en es Pees status icons always have priority over the trouble icons The display views the name of the provider and quality of the available signal Both information are alternately viewed N B This function is only available for control panels with GSM interface TP8 28 TP8 28 GSM 7 Tecn alarm Hi Tech Security Systems Bases SEB SE oz Trouble LED The system constantly controls its functioning The occurrence of a trouble is immediately signaled In case of active trouble the LED is blinking at the end of the alarm it is switched on permanently to signal that the alarm has been stored The stored alarm signal continues until it is cancelled with the appropriated procedure The troubles are also stored into the event buffer of the system Blinking slowly General trouble of the system Blinking quickly Trouble of the system s GSM module CM LED The CM LED command mode is lit as soon as the user starts typing on the keys It is lit during the entire access time and during 10 seconds after the last keystroke When the LED is switched off the user must enter the access code again to have access to
13. sarming confirmation delay a hold up alarm is released The Confirmation of disarming only functions if the transponder has been programmed with this attribute AD TP8 28 TP8 28 GSM 9 Tecn alarm Hi Tech Security Systems 10 TP8 28 TP8 28 GSM Hi Tech Security Systems Tecn alarm 2 ARMING WITH CODE 2 1 Arming It is possible to select which programs to arm Arming is made in three phases A Entering of the code B Selection of the programs to be armed C Confirmation Tue 21 FEB 12 Work 12 15 In case of error abort the process by pressing rep within 5 seconds then restart Complete Password entered on the display is ACCESS viewed ACCESS Master On the display is viewed Aki rming Confirm arming YE ie MAN ou Arming The programs 1 and 3 Control panel OK are armed Enter the access code While entering the code on the display is viewed Complete password Once the code has been Select the programs to be armed T On the display is viewed the confirmation of arming Tue 21 FEB 12 Work 12 15 nA 2 2 Disarming It is possible to select which programs to disarm Disarming is made in three phases A Entering of the code B Selection of the programs to be disarmed C Confirmation Tue 21 FEB 12 Work 12 15 In case of error abort the process by pressing CEP within 5 seconds then restart While enterin
14. the console Tamper alarm LED The LED signals the tamper alarms of the system The system s anti tamper protection is always active and is independent from the program status Off No tamper alarm Blinking Active tamper alarm On Stored alarm The stored alarm signal continues until it is cancelled with the appropriated procedure Battery status LED The LED indicates the status of the system s battery Off Battery OK Blinking Low battery On Battery fault i e the battery is no longer able to support the system Power failure alarm LED The LED signals the failure of mains power 230V AC Off No alarm mains power OK Blinking Active power failure alarm On Stored alarm The stored alarm signal continues until it is cancelled with the appropriated procedure Mains voltage LED The LED signals the presence of mains voltage 230V AC Off Mains voltage absent On Mains voltage present Transponder LED The LED signals that a transponder has been read and recognized by the integrated reader Off No transponder read or recognized Blinking once Transponder read and recognized Program status LED The LED signal the following states of each program disarmed arming phase armed and partset During the 10 seconds arming phase of the program the corresponding LED is blinking quickly and it is possible to arm disarm other programs and exclude the open zones from the alarm detection Off Program disarmed
15. wed by the programs The open zones are viewed the display and announced by the speaker of the console On the display is viewed the confirmation of arming of the control panel and exclusion of the open zones 2 6 Hold up alarm activation Arming is made in four phases A Entering of the code B Selection of the programs to be armed C Confirmation D The console signals the open zones acoustically and visually Press the YES key again to stop all the signaling The selected programs are armed and the open zones are excluded Only the enabled codes can active a hold up alarm Under duress it is possible to disarm the system apparently and activate the programmed hold up signaling by reducing by one unit the last digit of the code G TP3 28 TP8 28 GSM For example if the access code is 12345 to release the hold up alarm enter 12344 Tecn alarm Hi Tech Security Systems 2 Panic alarm activation At any time whether the system is armed or disarmed the program status is not relevant it is possible to release a panic alarm and activate the programmed signaling To release a panic alarm press the arrow up and down keys simultaneously The activation mode is valid for the Tue 10 JAN 12 j LCD300 S and the LCDPROX1 consoles Work 13 46 _ Tax 2 8 Consultation of the stored alarms The console views all the alarms which have occurred during the last

Download Pdf Manuals

image

Related Search

Related Contents

USER MANUAL  Hotpoint HM315I User's Manual  Integral 8GB DDR3  Rotel RA311 User's Manual  MS-Tech MC-1200SI computer case  "Le guide de la lecture numérique" [9e édition-Avril 2015]  Descargar manual  Dell PowerEdge R715 Information Update  Jester TLXtra User Manual  Scotts 50225 Installation Guide  