1. Manual SKIDSENS Fouling Sensor by Neosens Quick User Manual Installation Guide Advantage Controls P O Box 1472 Muskogee OK 74402 Phone 800 743 7431 Fax 888 686 6212 www advantagecontrols com 4 2011 email support advantagecontrols com Specifications Electrical Input 36 VDC 60mA e Output 4 20mA 500 Q Environment Ambient temperature 0 to 180 F without PVC adapter Relative humidity 0 to 100 Pressure 80 PSI Max Fouling Monitoring 0 1 mm 0 to 0 039 in Accuracy 1 of Full scale Material PVC body amp 316L SS sensor tip Connection e Sensors are supplied with a 1 2 54 cm slip and a 1 MNPT PVC quick oo The PVC adaptor has a maximum temperature rating Peak sensor body has 1 2 straight BMPT Shipping Weight 4 lbs 1 814 kg Sensor Length 9 375 23 8 cm Insertion Depth Approx 3 375 8 57 cm Installation Notes Install the sensor into flowing water for 30 minutes to allow the sensor to reach a temperature equilibrium Sensor must have a minimum of 3 5 gpm flow across it The analog output is active and referenced to 36Vdc If connected to a monitor with other 4 20mA inputs they must be isolated from each other or this input Contact Advantage Controls if a loop isolator is required After the sensor has been installed and powered for 2 hours confirm that the output is a 4mA signal Testing Sensor If the sensor is giving a 3mA output aft
2. eqoJgd SN3SdIMS BLACK HOT WHITE NEU S GREEN GND LE Part SS MAI 2 36 p100 J MOd J MOd INO eqoJqd vuoc v Input 2 Input 2 uonooeuuo SS UO ebay 104 Wesbeig Bui Megatron SS 4 20mA Input Input 3 Input 3 MegaTron Menus Customize Setup Step 1 First push the SET UP RUN button to get this screen From here push the CUSTOMIZE Button 4 to go to the next screen gt HOME SETUP lt SETPOINTS DATE TIME CALIBRATION CONFIGURE TIMERS HISTORY CUSTOMIZE WATER METER ALARMS RELAYS Step 2 This is the Customize Screen From here push the mA IN Button 9 to go to the next screen gt CUSTOMIZE UNIT NAME RELAY NAME NOTEPAD SYS NAME INPUT NAME mA IN RUN SCREEN Step 3 This is the mA IN screen From here push INPUT 1 OR 2 Button 1 or 2 then go to the next screen gt CUSTOMIZE mA INPUTS lt INPUT 1 INPUT 2 Step 4 This is the Customize mA Input 1 Screen From here push the NAME Button 1 to go to the next screen gt CUSTOMIZE mA INPUT 1 lt NAME FOULING UNITS mm NUMBER X XXX Step 5 Thisisthe Customize mAName screen Fromhere enter the name of the mA Input i e FOULING by using the Arrow buttons Then press ENTER to confirm and return to the previous screen gt CUSTOMIZE mA INPUT 1 NAME FOULING UN mA INPUT 1 NAME N F
3. Chemical Metering Pumps gt Corrosion Coupon Racks gt Chemical Solution Tanks gt Solid Feed Systems gt Feed Timers gt Filter Eguipment gt Glycol Feed Systems gt Pre Fabricated Systems Get the Advantage Advantage gt Controls
4. OULING USE ARROW KEYS TO CHANGE PRESS ENTER TO ACCEPT OR BACK TO ERASE Step 6 From here push the UNITS Button 2 to go to the next screen gt CUSTOMIZE mA INPUT 1 lt NAME FOULING UNITS mm NUMBER X XXX Step 7 This is the Customize mA Units screen From here select the type of units i e mm by using the Arrow buttons Then press ENTER to confirm and return to the previous Screen gt CUSTOMIZE mA INPUT 1 lt NAME FOULING UN TYPE OF UNITS NUM mm USE UP DOWN KEYS TO CHANGE PRESS ENTER TO ACCEPT Step 8 From here push the NUMBER Button 3 to go to the next Screen gt CUSTOMIZE mA INPUT 1 lt FOULING mm X XXX Step 9 This is the Customize mA Number Format screen From here select the number format i e x xxx by using the Arrow buttons Then press ENTER to confirm and HOME to return to the Home screen gt CUSTOMIZE mA INPUT 1 lt N EB FOULING UNI NUMBER FORMAT NUM X XXX USE UP DOWN KEYS TO CHANGE PRESS ENTER TO ACCEPT MegaTron Menus Calibration Setup Step 1 First push the SET UP RUN button to get this Screen From here push the CALIBRATION Button 2 to go to the next screen gt HOME SETUP lt SETPOINTS DATE TIME CALIBRATION CONFIGURE TIMERS HISTORY CUSTOMIZE WATER METER ALARMS RELAYS Step 2 This is the Calibration Screen Fr
5. er being installed for at least 2 hours in the minimum flow rate of 3 5 gpm the following steps can be followed to test and reset the sensor s operation 1 2 Power OFF the Skidsens Assuming the Skidsens was maintained in water with the required flow rate gt 3 5gpm power ON the Skidsens and check the analog output reading during the first 20 seconds as the probe will be in test mode a For the first 10 seconds the probe should display a 4mA signal b For the next 10 seconds the probe should display a 20mA signal After those initial 20 seconds the probe will go to operational mode and should return to a 4mA signal or slightly above assuming the sensor has no fouling Wiring Diagram for MegaTron Connection Sensor Input 4 20mA e Prona Dui 4 20mA Input Card GND S Q qn 2 8 4 20mA Input 5 4 20mA Input 54 o 4 20mA Input 8 Q Lo 4 20mA Input 8 Signal IRA 4 20mA In put 7 Or Power 1 4 20mA Input 7 36 Q 1 4 20mA Input 6 VDC Q o O 1 4 20mA Input 6 o o WHITE NEU NI GREEN GND a m S J1 8 Z uu 2 e Z E IRA 4 20mA Input 4 3 OJI x T ha o o 4 20mA Input 44 Lu z lt gt 1 m 4 20mA Input 3 1 4 20mA Input 3 12 4 20mA Input 2 1 4 20mA Input 2 o 4 20mA Input 1 o 4 20mA Input 1 J1 1 SKIDSENS Power Cord Probe Note The number of channels or 4 20mA LED q inputs depends on on the number ordered jnduj J0sueg YELLOW BROWN NN WHITE
6. om here push the mA IN Button 7 to go to the next screen gt CALIBRATION lt SENSORS Step 3 This is the Curren Loop Calibration screen From here push INPUT 1 OR 2 Button 1 or 2 then go to the next screen gt CURRENT LOOP CALIBRATION lt INPUT 1 INPUT 2 Step 4 This is the mA Input Calibration Screen From here choose the MAX or MIN Button 3 and 4 to go to the next screen gt mA INPUT CALIBRATION lt 20 mA 19649 4 mA 3913 MAX 1 000 mm MIN 0 000 mm OFFSET Enabled Step 5 This is the mA Input MAX screen From here adjust the MAX reading by using the number keys MAX should be set to 1 000 mm and MIN should be set to 0 000 mm Then press ENTER to confirm and return to the previous screen Note All other mA Input Calibration settings can be adjusted in the same fashion beginning at Step 4 gt mA INPUT CALIBRATION lt 20 mA 19649 4 mA 3913 MAX 1 NNN mm MINI mA INPUT 1 MAX 1 000 mm OFF s mm USE NUMBER KEYS TO CHANGE PRESS ENTER TO ACCEPT OR BACK TO ERASE Get the Advantage in Water Treatment Equipment Advantage Controls can give you the Advantage in products knowledge and support on all of your water treatment equipment needs Cooling Tower Controllers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Advantage Controls gt gt Water Meters gt