IFS MC352-1P/1S User Manual - Utcfssecurityproductspages.eu
Contents
1. Australia E techsupport interlogix au IFS MC352 1P 1S User Manual 25
2. 30 Watts power output e 10 100 1000Mbps duplex mode support on the1000Base T port e 1000Mbps support on the fiber optic port The MC352 1P 1S is a Single Port End Span Industrial IEEE 802 3at High Power over Ethernet Gigabit Media converter with maximum power output of up to 30 Watts over Ethernet cables It is designed specifically to meet the power requirements of network equipment such as PTZ Pan Tilt amp Zoom network cameras PTZ Speed Dome cameras color touch screen Video and Voice over IP VoIP telephones multi channel 11a b g n wireless LAN access points and other Network devices that need higher power to function normally The MC352 1P 1S Industrial High Power over Ethernet Gigabit Media converter is an ideal solution to deliver data and power to network devices directly via the RJ 45 Port interface without the need of installing extra power outlets and electrical cabling IFS MC352 1P 1S User Manual 3 Hardware Overview Figure 1 All Panel Views oo L i4ln HE T 2 onun 60020 o0020 DIN Rail Kit 4 IFS MC352 1P 1S User Manual Front Panel The Front Panel of the Industrial 802 3at PoE Media Converter consists of one 1000Base SX 1000Base LX mini GBIC SFP port and one Auto Sensing 10 100 1000Mbps Ethernet RJ 45 Port IFS MC352 1P 1S User Manual 5 Top Panel The top panel of the MC352 1P 1S Media Converter consists of one terminal block connec
3. 7 mem Re ceive 02 cote Los T meten mem Not used Ls meme T RJ45 Cable Drawing The following figure shows the pin allocation and color of a straight cable and connection of a crossover cable IFS MC352 1P 1S User Manual 23 Cross Over Cable a 12345 6 123465 SIDE 1 SIDE 2 SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 z White Blue 6 Green 7 White Brown 8 Brown SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 SIDE 2 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network 24 IFS MC352 1P 1S User Manual Contacting Technical Support Contact technical support if you encounter any difficulties during this installation Please make sure you have the requested diagnostic or log files ready before you contact us by phone or go to www interlogix com customer support Technical Support Europe Middle East and Africa W Select Contact Us at www utcfssecurityproducts eu North America T 1 855 286 8889 E techsupport interlogix com
4. Operating Wavelength Wavelength Distance dBm dBm Budget Temperature Fiber b Connector T oEiazsa FX 2 hauti rriei LC T310nm 1310nm Yem 202 44 32 12 S S25 2MLC 2 100B8aso FX 2 mock LC 1370nm 1310nm 2km 20 id de 12 40 75G 1310r 1310m Z km 15 34 13 S r 1310nm 13100m 40 75 C SD ILOADO t nBase EOL 520 181 8 20 1008359 BX20 0 1 Gigabit 1000MDbps RS TX RX Max Power RX San Power Operating PHY Type Fibers ibar Type Connector Wavsiangth Wavelangth Distance dBm dam Budget Temperature S30 RJ SFP 1000T Copper RU 45 100m 0 SC EXL2MLC 1000Base 5x 2 Mufl mezd Lc B n 220m 550m 8 5 4 17 75 EFC SX2MLC 1000Daee SX 2 Mulk mode Lc as5onm z n 220m 5590m 85 4 17 TS 40 TC faO0 MLC 2 TOOOERSO EXP 2 Miui nod Lc 1310nm 1310nm 2km S f 14 10 Sc LG LG Lo Lc Lc a mock Lc S30 15LC A 10 TODE ase DcTO UI 1 Sing mode Lc 1310nmi Tasar m T km J 20 11 30 C S3ASLC B 10 0110 1 Singe media Lc 1490nm iaon T km LE 20 11 50 C 530 1SLOA 20 TO00Basa BX 1 m da Lc 1310nm 1490nm zokm Su 23 5 0 50 C 550 151 20 0008560 BX20 D 1 moda Le T490nm 1310r 20km S 23 15 D uc SS 1SLOA 80 1000 PhO LI 1 Single mode LG 1310mm LEE eam 45 24 24 SG EXLISLC B 80 1OODBase BX amp O D 1 finge mode Lc 1420nm 1340nrim G km O 45 24 2
5. shuts down when its receiver fails to detect a valid connection LLR should only be enabled on one end of the link and is typically enabled on either the unmanaged or remote device The diagram below shows a typical network configuration with a good link status using MC352 1P 1S for remote connectivity Note that LLR and LLCF are enabled as indicated in the diagram Management Switch Hub Media Media Switch Hub Management Station w SNMP Converter Converter w SNMP Station 6 e Fiber Cable LED lit established link O LED unlit 2 no link If one of the optical conductors is bad as shown in the diagram box below the converter with LLR function will return IFS MC352 1P 1S User Manual 13 a no link condition to its link partner With LLCF function also enabled the no link condition is carried forward to the switch hub where a trap is generated to the management station Management Switch Hub Media Media Switch Hub Management Station w SNMP Converter Converter 5 Station Obs ero Link Loss Carried forward Link Loss Carried forward Port 2 Fiber iL Port 1 Link Loss Returned LED lit established link LED unlit no link Note The factory default setting for the LFP function is off This feature can also be turned on via the side DIP switch If the installer is familiar with the network installation and diagnostics i e checking which end is broken
6. 4 EFC uu BED chance k Based on 506125 ON fiber Requires laur op mized 50 125 OMEN ber to achieve ztkm distance Fiber sould bez tected andi verted To srandand 802 3at 802 3af Installation Before your installation it is recommended to check your network environment The MC352 1P 1S requires 48VDC or 24VDC input and it injects the DC power into the pin of the twisted pair cable Pin 1 2 3 and 6 16 IFS MC352 1P 1S User Manual I 550m 70km 100 meters 2405 lt A8V Output Industrial DIN Rail Power Supply Fiber Switch PoE Fiber cable Category 5e or better Speed Dome 1000Base SX LX Fiber optic 10008ase T UTP with PoE Power Line AC Power Line DC LED indicators System Function Lit indicates that power 1 is on Green Lit indicates that power 2 is on FAULT ee Lit indicates that either power 1 or power 2 has no power Gigabit Fiber Interface Function Fiber Lit indicates that the Fiber Optical Port is successfully LNK ACT connecting to the network at 100Mbps 1000Mbps Blinks indicates that the Fiber Optical Port is receiving or sending data Gigabit TP Interface IFS MC352 1P 1S User Manual 17 Lit indicates that the Gigabit Ethernet Port is successfully TP connecting to the network at 10 100 1000Mbps LNK ACT Blinks indicates that t
7. 5 50 400 500 0050 80 580 000 1000Base MM 62 5 5 550 LX 50 4 80 MR SM 9 N A 5000 Note The single mode port 1000Base LX port of the MC352 1P 1S is compliant with LX 5 kilometers and provides additional margin allowing for a 10 30 70 kilometer Gigabit Ethernet links on single mode fiber 20 IFS MC352 1P 1S User Manual Specifications Model MC352 1P 1S Hardware Specification 10 100 1000Base T 1 Port RJ 45 interface auto negotiation and Port auto MDI MDI X 1000Base X Fiber Vary on SFP Module Fiber Cable Cable Distance Optical Frequency Vary on SFP Module Receive Sensitivity Maximum Input power IEEE 802 3at 802 3af PoE Port 1 End Span 1 2 3 6 System Power 1 Power 2 and Fault LED Green Fiber port LNK ACT Green 10 100 1000Base T port LNK ACT PoE In use Green Orange LFP DIP Switch ON OFF Back pressure for half duplex IEEE 802 3x Pause Frame Flow Control for full duplex Maximum Frame Size 9216 bytes Power 24 and 48V DC redundant power with polarity reverse Requirement protect function IP 30 Aluminum metal case Enclosure Dimension 9 135x87 x 32mm Weight 5109 DIN rail kit and wall mount ear 6KV DC 6KV DC Mam Provides one relay output for power fail Alarm Relay current carry ability 1A DC 24V Speed Twisted pair 10 20Mbps for Half Full Duplex 100 200Mbps for Half Full Duplex 1000 2000Mbps for Full Duplex IFS MC352 1P 1S User Ma
8. IEEE 802 3u 100Base TX IEEE 802 3ab 1000Base T and IEEE 802 3z 1000Base SX LX standards The Gigabit media conversion is quick and easy by simple plug and play installation The MC352 1P 1S series Industrial 802 3at High Power over Ethernet Gigabit Media converter also supports flow control and back pressure in half duplex operation to eliminate packet loss Package Contents Check the contents of your package for the following parts e MC352 1P 18 x1 Users Manual x1 DIN Rail Kit x 1 e Wall Mount Kit x 1 If any of these items are missing or damaged please contact your distributor or IFS sales rep immediately If possible retain the original carton and packaging material in case you need to return the product for repair replacement IFS MC352 1P 1S User Manual 1 Product Description The MC352 1P 1S extends communication distance with high Gigabit performance via fiber optical wire in which the extension distance can be up to 70km The 52 1 15 is specifically designed with durable components and an P 30 rated enclosure to operate reliably in electrically and demanding environments The industrial Gigabit media converter provides a high level of immunity to electromagnetic interference and heavy electrical surges which are usually found on plant floors or traffic control cabinets along highways Being able to operate under the temperature range from 40 to 75 Degree C allows the MC352 1P 1S to be used in almost any
9. below this Manual uses the IFS GE DSGH 8 as an example However the steps for any IFS Industrial Switch amp Industrial Media Converter are similar Mounting to a DIN Rail The DIN Rail kit comes assembled on the MC352 1P 15 out of the box Please refer to following figures to mount the MC352 1P 1S on a DIN Rail 8 IFS MC352 1P 1S User Manual 1 Lightly press down and push the bottom of the DIN Rail connector mount into the track 2 Check that the DIN Rail connector mount is tightly mounted on the track 3 Please refer to following procedures to remove the MC352 1P 1S from the track IFS MC352 1P 1S User Manual 4 Lightly press down and pull the bottom of the DIN Rail connector mount to remove it from the track Mounting to a Wall To install the MC352 1P 1S on the wall please follow the instructions described below 1 Loosen the screws to remove the DIN Rail from the Media Converter 10 IFS MC352 1P 1S User Manual 2 Place the wall mount plate on the rear panel of the MC352 1P 1S 3 Assemble the wall mount plate on the MC352 1P 1S 4 Use the hook holes at the corners of the wall mount plate to mount the 2 1 15 on the wall IFS MC352 1P 1S User Manual 11 Link Fault Pass through LFP The LFP refers to the Link Fault Pass Through function LLCF LLR and the DIP Switch settings LLCF LLR can immediately notify administrators about a problem with the link media The DIP Swi
10. demanding environment The maximum distance between the PoE PSE to PD is 100 meters To extend the network device deployment range the MC352 1P 1S is designed with a fiber interface The MC352 1P 1S is used to convert an optical Ethernet signal to an electrical Ethernet signal that allows two type segments to connect easily efficiently and inexpensively It can convert 10 100 1000Base T signal to 1000Base SX LX and provides the diverse options of fiber connecting types to meet different network applications With the long Fiber distance support it still sustains the transmission performance as high as 1000Mbps It works in a high performance Store and Forward mechanism and also can prevent packet loss with IEEE 802 3x Flow Control Full Duplex and the LFP Link Fault Pass Through function LLCF LLR with a DIP Switch setting Furthermore it can immediately notify the network administrator the issue with an alarm from the link media which provides an efficient solution to monitor the network power usage To fill the growing demand of Industrial PoE PD devices that need higher Power Input and long distance transmission the 2 IFS MC352 1P 1S User Manual MC352 1P 1S Industrial Media converter that complies with IEEE 802 3at High Power over Ethernet technology The MC352 1P 15 provides the following key features e EEE 802 3at Power over Ethernet standard compliance e IEEE 802 3af Power over Ethernet standard compliance e Maximum
11. he Gigabit Ethernet Port is receiving or sending data Lit indicates that the Gigabit Ethernet Port is successfully connecting to the network at 1000Mbps OFF indicates that the Gigabit Ethernet Port is successfully connecting to the network at 10 100Mbps TP 1000 Function Lit Indicates that the port is providing DC 52V to remote powered device Off Indicates that the port is not providing DC 52V to remote powered device Function Lit Indicates that the device is powered 18 IFS MC352 1P 1S User Manual 10 100 1000Base TX Port LED O70 fo g Function Lit Indicates the link through that port is successfully established areen Blinking Indicate that the port is actively sending or receiving data Lit Indicates a 1000Mbps Full duplex connection TP 1000 Green Off Indicates a 10 100 Mbps Full duplex connection 1000Base SX LX SFP Slot Function Lit Indicates a successful link through the fiber port Blinking Indicates the data activity through the fiber port IFS MC352 1P 1S User Manual 19 Cable Connection The recommended cable types are listed below Cables Standard Fiber Type Cable Specification 1000Base SX Multi mode 50 125um or 62 5 125um 850nm 1000Base LX Multi mode 0 125umor62 S 125um 1 1300nm Single Mode 9 125um Fiber Distances Standard Fiber Diameter Modal Bandwidth Max Distance micron MHz km meters 1000Base MM 62 5 100 220 SX 62 5 200 27
12. in a connection you can turn the switch to the on position and reset the converter for changes to take effect Otherwise it s recommended to keep the DIP switch in its default position 14 IFS MC352 1P 1S User Manual Stand alone Installation Please follow these steps to install the 52 1 15 The SFP transceivers are hot swappable you can insert or remove the transceiver from an SFP port without having to power down the Industrial 802 3at PoE Media Converter To install the MC352 1P 1S with 100Base FX 1000Base SX LX SFP simply complete the following steps Step 1 Insert in the 100Base FX or 1000Base SX LX SFP Make sure the same type of SFP modules are used on both side i e 100Base FX 2km to 100Base FX 2km 1000Base SX 220m amp 550m to 1000Base SX 220m amp 550m etc Step 2 Connect the fiber cable Attach the duplex LC connector on the network cable into the SFP transceiver DC 24V 48V m HHN p p n Fiber Switch SFP Module SFP Module M 13 amp UE 4 b z PoE IP Camera ia yay Note It is recommended to use 1000Base SX LX SFP modules available in the IFS Transmission product line A SFP transceiver module that is not supported will not be recognized by MC352 1P 1S media converter The following list provides the available SFP modules for the MC352 1P 18 IFS MC352 1P 1S User Manual 15 SFP Table Fast 100MDbps TX RX Max Power RX S n Power
13. m El interlogix A UTC Fire amp Security Company s MC352 1P 1S User Manual ENIM P N 1072579 REV R00 03 ISS 10SEP12 Copyright Trademarks and patents Manufacturer Version Certification FCC compliance ACMA compliance European Union directives O 2012 UTC Fire amp Security Company All rights reserved Interlogix IFS 52 1 15 the IFS Brand and logo are trademarks of UTC Fire amp Security Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products UTC Fire amp Security Americas Corporation Inc 2955 Red Hill Avenue Costa Mesa CA 92626 5923 USA This document applies to IFS 52 1 15 version 1 0 C Qu Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice This is a Class A p
14. nual 21 LED Indication Fiber optic 200Mbps 2000Mbps for Full Duplex 10 100 1000Base T 2 Pair UTP Cat 3 4 5 5e 6 100 meters max EIA TIA 568 100 ohm STP 100 meters max 100Base FX 1000Base SX LX Multi mode 50 125um or 62 5 125um optic fiber Single mode 9 125um optic fiber 24V 4 3 Watts 14BTU 48V 4 8 Watts 16BTU Without Power PoE Consumption 24V 33 Watts 112BTU 48V 31 Watts 105BTU With PoE Network Cables Power over Ethernet PoE Standard IEEE 802 3af 802 3at High Power over Ethernet PSE PoE Power Supply Ehdispan Type 52V DC 15 4 VVatts PoE Power Output gt V DC 30 Watts Power Pin PoE Budget 30 Watts Standards Conformance IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX Fast Ethernet IEEE 802 3ab 1000Base T Gigabit Ethernet IEEE 802 3z 1000Base SX LX Gigabit Ethernet IEEE 802 3x Full Duplex Flow Control IEEE 802 3af Power over Ethernet IEEE 802 3at High Power over Ethernet IEC60068 2 32 Free fall Stability Testing IEC60068 2 27 Shock IEC60068 2 6 Vibration Standards Compliance When connecting to other Ethernet equipment such as a Router Bridge Switch or Hub please refer to that device s Technical Manual 22 IFS MC352 1P 1S User Manual RJ45 Pin Assignments 1000Mbps 1000BaseT Contact MD MDX BI BI_DC 10 100Mbps 10 100Base TX MDI MDI X Contact Media Dependant Media Dependant Interface Interface Cross
15. roduct In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 2004 108 EC EMC directive Hereby UTC Fire amp Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC Contact information Customer support 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info www utcfireandsecurity com or www interlogix com www interlogix com customer support Contents Overview 1 Package Contents 1 Product Description 2 Hardware Overview 4 Front Panel 5 Top Panel 6 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 7 Mounting Installation 8 Link Fault Pass through LFP 12 Link Loss Carry Forward LLCF 12 Link Loss Return LLR 13 Stand alone Installation 15 802 3at 802 3af Installation 16 LED indicators 17 Cable Connection 20 Specifications 21 RJ45 Pin Assignments 23 Contacting Technical Support 25 IFS MC352 1P 1S User Manual Overview The MC352 1P 15 Industrial 802 3at High Power over Ethernet Gigabit Media converter fully complies with IEEE 802 3 10Base T
16. tch enables or disables the LFP function LLCF Link Loss Carry Forward detects the connection loss on the TP line and LLR Link Loss Return detects the connection loss on the fiber line Link Loss Carry Forward LLCF MC352 1P 1S incorporates an LLCF function for troubleshooting a remote connection When the LFP function is enabled the FL TP ports do not transmit a link signal until they receive a link signal from the opposite port The diagram below shows a typical network configuration with a good link status using MC352 1P 1S for remote connectivity Management Switch Hub Media Media Switch Hub Management Station w SNMP Converter Converter 5 Station es 6 Fiber LED lit established link O LED unlit 2 no link In case of a connectivity issue the MC352 1P 1S media converter LLCF sends the notification to the switch hub that generates a trap to the management station 12 IFS MC352 1P 1S User Manual Management Switch Hub Media Media Switch Hub Management Station w SNMP Converter Converter 5 Station e 6 ore Broken O e o e e 6 LED lit established link LED unlit no link The factory default setting for the LFP function is off Link Loss Return LLR The fiber ports of the MC352 1P 1S have been designed with an LLR function for troubleshooting a remote connection LLR works in conjunction with LLCF When the LFP function is enabled the port s transmitter
17. tor within two DC power inputs oo T oo O10 OC O O o G O Vi Vie V2 V2 Input L DC24V 48V PVVR1 Fault PVVR2 Wiring the Power Inputs The 6 contact terminal block connector on the top panel of the MC352 1P 1S is used for two DC redundant power inputs Please follow the steps below to insert the power wires 1 Insert positive negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 qe uw m ou Vi V14 V2 V2 Input DC 24V 48V PVVR1 Fault PVVR2 V1 V1 V2 V2 2 Tighten the wire clamp screws to prevent the wires from disconnecting 6 IFS MC352 1P 1S User Manual Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the MC352 1P 1S will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts IFS MC352 1P 1S User Manual T Note The wire gauge for the terminal block should be in the range between 12 24 AWG The alarm relay circuit accepts up to 30V max 3A currents Mounting Installation This section describes how to mount the MC352 1P 1S and make connections to it Please read the following sections and perform the procedures in the order presented Note In the installation steps