TOSLINE-S20/S20LP S20 Loader (for Windows) User`s Manual

image

Contents

1. CS Specification 9 pin D Sub connector both ends PC side male Station side female Length 5 meters 3 2 Activating the Loader Use the RS 232C to connect your PC with a station before activating your S LS Loader The loader recognizes the station type bus topology or loop topology when activated An error message will appear when the loader is not connected with the station e Activating the Loader on Windows 95 The S LS will be activated generally in the following sequence when the installation has been completed successfully Start y Program y S LS loader system for Windows 95 y S LS loader system for Windows 95 The above operation allows the loader program to get activated to the following communication environment contirmation window appears TOSLINE S20 Loader System for Windows 6F3B0357 e Window Image pa E re 3 Communication Environment Setting Port No conn 1 BaudRate ano F m Stop Bit a arity Even Y ee gus 5 Data Bit Confirm Communication Environment Ata ES If no change the settings Select Continue If change the settings Select Change S LS tries to connect The Station by now settings The communication environment confirmation window is designed for changing connection conditions with stations in future Therefore the window is wrrently unavailable Press the Continue button This oper
2. Read the information again From the menu select File Read The Scan Address display is updated 3 Display the Scan Transmission Information Setting window Doubleclick the No Kind display area in the Scan Address List The Scan Transmission Information Setting window of the corresponding station appears asie TOSLINE S20 Loader System for Windows 6F3B0357 4 2 Setting Information Displaying and setting the parameters of individual stations are available However these operations are available only when the station selected is in standby mode The following information can be set 1 Scan Transmission Information 2 Station Control Information 3 SIF Setting Information TOSLINE S20 Loader System for Windows 4 2 1 Scan Transmission Information e The Function The scan transmission information of the station being selected can be set or displayed e Window Image q Setting Information Menu M File Operation EJ fos x B Station Number 1 64 lt Setting tem2 Station Type Fa Send Starting Address 1 1032 8 Number of Send Words 1 foos2 gt Send Starting Address 2 foooo Number of Send Words 2 foooo OK Renew Cancel e Station Type 0d 2 3 4 5 6 7 8 9 10 an 12 13 14 15 Bus topology Loop topology T4 T4 station 1 G200H G200H station T3 T3 station 2 MC
3. The following Confirm window appears Test Request 2 Execute No Click on the OK button A hardware test is executed 39 TOSLINE S20 Loader System for Windows 6F3B0357 2 Station loop back test e Test Request lt Test Type gt m C Hardware Test Ry Station Loop back Test Station Number 1 64 Stn No 03 y Stn No 04 i Stn No 05 Tarnet Station 02E 18 Test Count 100 Times Select a request type for station loop back test Select a station you want to test Enter the number of the test times Click on the Execute button A Confirm window will appear Click on the OK button A station return test is executed Test Executing Test Executing Test Count 6 Click on the Break button when suspension is necessary A station return test is breaked ete TOSLINE S20 Loader System for Windows 6F3B0357 4 7 Communication Environment e The Function Sets up the communication environment for the TOSLINE S20 Loader System Except for setting up the communication port in the following 1 special key operation is required While pressing the Ctrl key click on the icon at the upper left in the Communication Environment Setup window for unlocking e Window Image environment setup Z Communication Environment Setting Port No cona 1 BaudRate 9600 M Stop Bit t 1 Parity Even Ej Cas Data Bit ls
4. ee TOSLINE S20 Loader System for Windows 6F3B0357 4 2 4 Saving All Station s Information e The Function Currently all of the setting information of the individual stations being connected with the system can be saved 1 Scan transmission information 2 Station control information 3 SIF unit setup information e Window Image Menu M Add Di L Display Station Down Information D Save Files All Station s Information A Exit 09 Relf Station Statinn No Mi e How to Operate From the menu select File Save Files All Stations s Information in the Station Connection Diagram A dialog box appears for specifying a saving directory Set a saving directory name in the dialog box The Setting information file of the individual stations is output onto the directory specified TOSLINE S20 Loader System for Windows 6F3B0357 4 3 Data Access Reading and writing are available for the scan memory of the stations being connected Specify a station number and the top address to access the scan area The data display format in decimal or hexadecimal notation can be selected The data at the same address can be read out periodically 2 second cycle for display by checking Cyclic Data Read Scan data can be read and written to from a file e Window Image 25 TOSLINE S20 Loader System for Windows 6F3B0357 4 3 1 Access to Scan Area e The
5. O Terminate the S20 Loader program TOSLINE S20 Loader System for Windows 6F3B0357 2 5 Difference Between the TL S20 bus topology and the TL S20LP loop topology The following table lists the differences found between the TL S20 bus topology and the TL S20LP loop topology in terms of functions O Function Yes X Function No 1 Station Connection Connection Diagram Diagram display A rangement O Scan Transmission Address List 2 Setup Information Scan Transmission Information 3 Data Access Access to Scan Area O Oe i Or i ee A Memory Area ko ca E Area n ae AECA Memory Area mas iomaton kon o o OO o i fee O l a A Ou AO PT sins O l oo sia oun eat OO o i someoen O O En omera 0 o O o yi ea JO dT 6 Test Request Hardware Test O ski AE 7 Communication Communication Environment Setup Environment Setup TOSLINE S20 Loader System for Windows 6F3B0357 3 Starting Up the Loader 3 1 Connecting with a Station The S20 Loader on a PC connects with a S20 transmission station via an RS 232C cable This allows the loader to set up and monitor the transmission station and the other remote stations being connected via transmission cable Use the following type of transmission cable to connect the 9 pin connector male on the PC with the 9 pin connector female on the S20 transmission station for LOADER for the T series connection O Transmission cable Product code TCJ905
6. right corner of the window A dialog box appears for specifying a file name to be read In the dialog box set up the path of the file name to be read From the path specified the setup information of the corresponding station is read and displayed TOSLINE S20 Loader System for Windows 6F3B0357 4 2 3 SIF Setting Information e The Function The SIF setting information of the station selected can be set and displayed This function is available for the TL S20 bus topology only e Window Image q Setting Information Menu M File Operation E Station Number 1 64 for 5 B B Port Select Port 1 C Port 2 BaudRate 9600 ac fanii Even Parity Stop Bit Length Data Bit Length Flow Control Picea C768 Yes t No M Transmission T ransmission ype Multi Cont issi Address Message Transmission 0 9 F No F vi gt Virtual Circuit Target Port None y ka pe e 0 l HK Renew Cancel e Possible Setup Items Set the information by ports port 1 port 2 1 Baud rate 300 600 1200 2400 4800 9600 19200 BPS 2 Data length 7 8 bits 3 Stop bits 1 2 bit 4 Parity bit none odd parity even parity 5 Yes No of flow control 6 Transmission type message transmission free run broadcast 7 Virtual Circuit target station none 1 to 64 8 Virtual Circuit target port none 1 2 9 Multicast address none 0 to 9 TOSLINE S20 Loader System for Wind
7. space 20 MB or more TOSLINE S20 Loader System for Windows 6F3B0357 2 2 TL S20 bus topology Connection and TL S20LP loop topology Connection lt Bus topology connection gt Loader TL S20 TL S20 lt Loop topology connection gt Loader TL S20LP TL S20LP TL S20LP TOSLINE S20 Loader System for Windows 6F3B0357 2 3 Installing Your S LS The S LS for Windows is provided with the following media For Windows 95 two 2HD floppy disks e Setup disk 1 2 e Setup disk 2 2 Install your S LS by executing SETUP EXE in setup disk 1 2 in the following way Insert setup disk 1 2 for Windows 95 into the floppy disk drive Start Specify file name to execute A SETUP EXE OK After executing SETUP EXE follow the instruction appearing in the window TOSLINE S20 Loader System for Windows 6F3B0357 2 4 Operating Procedure This manual allows you to execute the S20 Loader in the following sequence W Connecting with a Station O Connect your S20 Loader on a PC with an S20 S20LP transmission station via an RS 232C cable 2 ho Activating the Loader program O Activate the Loader program O Select specific functions from the station connection diagram O Select a station Station Connection Diagram Selecting a station 4 2 Executing Commands O Setup parameters by commands to execute Termination
8. station you want to rearrange while pressing the Shift key The moving icon appears While pressing the Shift key move the dragging station to a position where you want to display and then drop the icon The station you dragged appears at the display position you dropped it 2 Register the rearranged display position information From the menu select Option Station Display Position Registration The current station display position information is registered Since this time the Station Connection Diagram window displays the stations in the order of the display positions registered 3 Return the station display positions to the standard display positions From the menu select Option Station Display Position Normal The stations appear in the ascending order of smaller display position numbers j5 TOSLINE S20 Loader System for Windows 6F3B0357 4 1 5 Scan Address List e The Function Displays the scan address list of the stations being connected with the system When an overlapped scan address is found in multiple stations the address appear colored This address appears only for the onlined or standby station e Window Image Address 909 39 0000 0000 1124 1223 0000 0000 D000 0000 1032 1063 0000 0000 e How to Operate 1 Display the Scan Address List window From the menu select Menu Display Scan Address List The Scan Address List window appears 2
9. CS Ton ee e Setup Items 1 Communication port COMM 1 to COMM 16 2 Baud rate 1200 2400 4800 9600 19200 BPS 3 Parity none odd parity even parity 4 Data length 7 8 bits 5 Stop bit 1 1 5 2 bits The underline data indicates the default setting TOSLINE S20 Loader System for Windows 6F3B0357 e Window Image how to communicate Z Communication Environment Setting Receive Buffer Size 1024 Byte Length of Read String 0 Byte Transmit Buffer Size 512 Byte Substituted Character at Parity Error fa NULL Transmit Enable False e en e Setup Items 1 Receive buffer size 1024 2 Character string size to be read 256 3 Transmit buffer size 512 4 Replacement Character on parity error 2 5 Whether Null is transferred to the receive buffer True False The underlined data indicates the default setting 4 TOSLINE S20 Loader System for Windows 6F3B0357 e Window Image detailed setup Z Communication Environment Setting Environment Method Detail Setting DTR Line Enable False RTS Line Enable True Handshake Setting MON AHOFF RX OnGomm Event Interval 0 Each Character TX OnGomm Event Interval D Each Character Tan a e Setup Items 1 2 3 4 5 Whether DTR line is set to active or not True False Whether RTS line is set to active or not True False Setting handsh
10. Function The scan area of the stations being selected can be set and displayed e Window Image A Data Display Format Decimal Scan Data Access w Execute Station Number 1 64 ot MC Starting Address 0 406 pooo B Number of Read Data Words 1 16 16 MC Cyclic Data Read Data Write Return e How to Operate 1 Displaying values Set the station number top address number of words to be read in the data access menu Click on the Execute button The data of the station selected appears 2 Continuous data read Check the check box for Cyclic Data Read in the window and click on the Execute button The data at the same address is read periodically 2 seconds cycle for display 3 Changing the data display format Click on the Decimal or Hexadecimal button in the window The data display format is changed over to the one specified display on the button is in current format SE TOSLINE S20 Loader System for Windows 6F3B0357 4 Setting values during Cyclic Data Read no setup operation is available Click on the data you want to set Change the data you want to set Click on the Data Write button The data changed is sent to the corresponding station 5 Saving data in a file While the data is being displayed in the window select File Operation Save As menu or click on the Save As button in the window A dialog box appears for sp
11. R25 MCR station T2 T2 station 3 PTLS9 PCS station HTI Handy terminal interface 4 SBL22 Signal transmission device station PLC 5 PLC 5 5 T3H T3H station PC AT PC AT bus 6 TS25 Modem interface SIF Serial interface MDMOS MDMOS PC98 PC9801 SG MCR22 PCS PCS4000 6000 7000 VME VME bus CYCLO TOSCYCLO u H850 U S TOSVERT u S250 VF TOSVERT VF For the station undefined the station type code is displayed 18 6F3B0357 TOSLINE S20 Loader System for Windows 6F3B0357 e Possible Setup Items 1 Transmission top address 1 TL S20 0 1023 TL S20LP 0 4095 2 Number of transmission words 1 0 1024 3 Transmission top address 2 TL S20 0 1023 TL S20LP 0 4095 4 Number of transmission words 2 0 1024 e How to Operate 1 Setting values Enter the values of transmission top address 1 number of transmission words 1 transmission top address 2 and number of transmission words 2 Enter values directly or select from the combo box or using the spin button Click on the OK or Update button The data you set is transmitted to the corresponding station 2 Canceling the values after setup Click on the Cancel button The data you set becomes invalid and the Setting Information window disappears 3 Selecting a station Select a station number from the combo box or using the spin button The window is changed over to the selected station information 4 Saving
12. TOSHIBA 6F3B0357 TOSLINE S20 S20LP S20 Loader for Windows User s Manual Main Menu Contents May 1998 Toshiba Corporation UM TLS20 E006 TOSLINE S20 Loader System for Windows 6F3B0357 Contents Ti INTO rra 3 2 Before Op6ralAG sisecicssccsccarsnccancnaesnasasscancsananennnctanccatondicnascadcenasanaacearetneseacs 4 2 1 What is S20 Loader 2 2 TL S20 bus topology Connection and TL S20LP loop topology Connection 2 3 Installing Your S LS 2 4 Operating Procedure 2 5 Difference Between the TL S20 bus topology and the TL S20LP loop topology 3 Starting Up the LOGS second 9 3 1 Connecting with a Station 3 2 Activating the Loader SA A 11 4 1 Station Connection Diagram csecsecseseenseeesseneseesssessseessensnssensseeseseneeseeeeeeeees 11 4 1 1 Standard Size Window 4 1 2 Small Size Window 4 1 3 Transmission Error 4 1 4 Rearrangement 4 1 5 Scan Address List AD Setting Information 17 4 2 1 Scan Transmission Information 4 2 2 Station Control Information 4 2 3 SIF Setting Information 4 2 4 Saving All Setting Information da DAA ca 25 4 3 1 Access the Scan Area A4 RAS IOMA Mais 29 4 4 1 Online Map 4 4 2 Scan Healthy Map 4 4 3 Loop Map 4 4 4 Station Status 4 4 5 Station Down Information 4 4 6 RAS Counter Information TOSLINE S20 Loader System for Windows 6F3B0357 AS Oniline Standby Request iii 37 4 6 TEST ROQUES ii 39 4 7 Communication EnvirOohMeNt occccccccn
13. aking XON XOFF CTS RTS Occurrence interval of reception OnCom event 1 to 256 per character Occurrence interval of transmission OnCom event 1 to 256 per character The underlined data indicates the default setting as E TOSLINE S20 Loader System for Windows 6F3B0357 5 Termination Terminate the S20 Loader from the menu or the toolbar e Menu a A a a Station Connections Loop Type File F Menu M Option O Window WW Help H File 1 se seesseeanes sten sveanostonanoosososoen Exits the application e Toolbar Exit button button at left end Exits the application 891005393 Toshiba Corporation
14. ation allows the system configration diagram base window to appear 10 TOSLINE S20 Loader System for Windows 6F3B0357 4 Operation 4 1 Station Connection Diagram 4 1 1 Standard Size Window e The Function Displays at a glance the types and statuses of the stations being connected The window can transmit into any of the individual TOSLINE S20 Loader System windows by selecting a station e Window Image a Station Connections Loop Type File Menu W Option Q Window W Help H BASAH p Station Connections gt lt Connection status gt Common with bus topology and loop topology Station ico Station ico Station ico Online Standby Offline or not connected lt Transmission status gt For loop topology only Normal Transmission Transmission loop 2 abnormal loop 1 abnormal Ala eee TOSLINE S20 Loader System for Windows 6F3B0357 e The Menu CIA yn A a a Station Connections Loop Type File F Menu M Option 0 Window CW Help H Individual TOSLINE S20 Loader System windows can be displayed from the menu or the toolbar Below are the details of the menu Select an intended station in the Station Connection Diagram window for display and specify the window in the menu or the toolbar File Display Scan Address List 0 0 0 Displays the Scan Address List window Display Station Down Information Displays Down Informati
15. ation menu The Scan Healthy Map window appears oh co TOSLINE S20 Loader System for Windows 6F3B0357 4 4 3 Loop Map e The Function The loop statuses of individual stations are displayed This function is not found in the TL S20 bus topology e Window Image Terminal Cut off Terminal Through Terminal End 1 Terminal End 2 General Through General End 1 General End 2 No Mark Offline or No Station e Status Types Display mark EME ECTS IT TN CN EIC z Endl Loop 1 side transmission disabled Loop 2 side reception disabled End2 Loop 2 side transmission disabled Loop 1 side reception disabled e How to Operate Select Loop Map from the RAS information menu The Loop Map window appears 3 TOSLINE S20 Loader System for Windows 6F3B0357 4 44 Station Status e The Function Reads and displays the station status of the station specified e Window Image 5 Station Status Sit sen ba MON ON ot 1B Status Display lleno ff Details No Execution ternal Eouioment 2 Error No Connect Note External Equipment 2 is valid only for SIF Station e Display Items 1 Online status online offline standby 2 Master station Slave station mode 3 Scan transmission inhibit allow inhibit allow 4 Test execute not execute 5 External device 1 normal abnormal not connected 6 External device 2 normal abn
16. ecifying a file name to be saved Specifying a file name in the dialog The data being displayed is output onto the file name specified 6 Reading the data in a file from the Select File Operation Read from File from the menu Or click on the Read File button in the window A dialog box appears for specifying a file name to be read Specifying a file name to read in the dialog Data is read from the file specified for display TOSLINE S20 Loader System for Windows 6F3B0357 e Window Image Data display status T a m Data Access an e Window Image Dialog for specifying a file name File Open 21x el cl ez Jexe1113 WJ Exe1114 Scan Data Inf Save File DT1 y LI 28 TOSLINE S20 Loader System for Windows 6F3B0357 4 4 RAS Information The RAS information generated in station is read When the RAS information on the toolbar in the Station Connection Diagram window is clicked on the RAS Information menu appears By selecting a window you want to display from the RAS Information menu the window appears The RAS Information has the following six types of windows 1 Online Map Displays the connection status of individual stations 2 Scan Healthy Map not found in the TL S20LP loop topology Displays execution status of scan transmission by the word in the scan area 3 Loop Map not found in the TL S20 bus topology Display
17. eh ooninicionininicnnnnnnincncncnonos Displays the Retrieve window in Help Version Information oooocnoncioninnnncnninonons Displays the information of the application version e The Toolbar Function The toolbar has buttons for the functions frequently used The following buttons are found from left to right Exit button cece Exits the application Setting Information button 0 Displays the Setup Information window Data Access button 0 0 0 ceeseeeeeeseeseeeeeeees Displays the Data Access window RAS Information button Displays the RAS Information Menu window Online Standby Request button Displays the Online Standby Request window Test Request button u rrrereeroereroosoonee Displays the Test Request window TOSLINE S20 Loader System for Windows 6F3B0357 4 1 2 Small Size Window The small size window can display up to 64 stations in the 800 x 600 dots resolution This window has the equivalent functions as the standard size window e Window Image E Station Connections File E Menu D O ption O Window W Help H Self Station Station Na NM Nnline m Station Connections gt CAR PEPA ee a Ze MO a a gi m a ga 2 gi E y os wua w wob i W ui is a i w hi gi W hi gi W kl gi m a a hi sw e a gi hi EEEE Different types of stati
18. in the file one corresponding station Select Save As from the menu or click on the Save As button in the upper right corner of the window A dialog box appears for specifying a file name to be saved Set up the path of the file name to be saved in the dialog box The setup information file of the corresponding station is output to the path specified 5 Reading from the file one corresponding station Select Read File from the menu or click on the Read File button in the upper right corner of the window A dialog box appears for specifying a file name to be read Set up the path of the file name to be red in the dialog box From the path specified the setup information of the corresponding station is read and displayed ae PA TOSLINE S20 Loader System for Windows 4 2 2 Station Control Information e The Function The station control information of the station being selected can be set and displayed e Window Image q Setting Information Menu M File Operation E Station Number 1 64 fot 13 Scan Transmission Enable C Disable Message Transmission Enable C Disable fiw C24 Sean Access O gt e Possible Setup Items 1 Inhibits allows scan transmission 2 Number of scan access words 1W 2W 3 Inhibits allows message transmission 4 Target cycle time Psi ea CO ECO CA 5 Standby startup yes no 29 Target Scan Ti
19. ion clear allowed Station information clear inhibited Entering In The Network Station type Getting Out The Network ROM Rev Network Error Date of creation Block check code BCC_L BCC_H 35 TOSLINE S20 Loader System for Windows 6F3B0357 e How to Operate 1 Displaying the RAS Counter Information window Select RAS Counter Information from the RAS Information menu The RAS Counter Information window appears 2 Cyclic reading information Check Cyclic Reading in the check box in the window RAS Counter Information is read cyclically 2 seconds for display 3 Clearing information in the RAS counter Select Operate Clear Counter from the menu A message box appears to confirm the execution of clearing the information Click on OK in the Confirm message box RAS Information Counter is cleared TOSLINE S20 Loader System for Windows 6F3B0357 4 5 Online Standby Request 4 5 1 Online Standby Request e The Function An Online Request or Standby Request is issued for the station selected This request is always available for the local station where the S20 loader is connected For the other stations this function is available when the local station is onlined or in standby e Window Image Ta Online Standby Request Menu M Option O Request Station Number 1 64 38 neers lt Request Type gt Standby Request Return e Operation 1 On
20. line Standby request to a station selected Select the station number Select the request type Click on Execute button The request selected is issued for the station selected 37 TOSLINE S20 Loader System for Windows 6F3B0357 2 Online Standby request for multiple stations Select Option Operate Multiple Stations from the menu A window for operating multiple stations appears Select the stations you want to request The stations selected appear reversed Standby Request Stn No 01 Select a request type Click on the Execute button The request selected is issued for the multiple stations selected TOSLINE S20 Loader System for Windows 6F3B0357 4 6 Test Request e The Function Hardware test Checks the ROM area setup switch and the station for the appropriateness for the local station only Hardware test is available in standby mode only Note Separate the station from the other stations Otherwise some of them may get mal functioned Station loop back test Transmits data between the local station and the station specified e Window Image e Test Request lt Test Type gt Hardware Test Sie Station Loop back Test Station Number 1 64 Target Station Y 18 Test Count Times e Operation 1 Hardware test Select the station you want to test Select a request type for hardware test Click on the Execute button
21. m 61 47 sec Start with Standby mode Cancel 6F3B0357 TOSLINE S20 Loader System for Windows 6F3B0357 e How to Operate 1 2 3 4 5 Setting inhibit allow scan transmission number of scan access words inhibit allow message transmission and standby startup check box Select either of the values in the window Click on the OK or Update button The data you set is transmitted to the corresponding station Setting a target cycle time From the combo box select the target cycle time you want to set Click on the OK or Update button The data you set is transmitted to the corresponding station Canceling the values after setup Click on the Cancel button The data you set becomes invalid and the setup information window disappears Selecting a station Select a station number from the combo box or by using the spin button The widow is changed over to the selected station information Saving in a file one corresponding station Select Save As from the menu or click on the Save As button in the upper right corner of the window A dialog box appears for specifying a file name to be saved Set up the path of the saving file name in the dialog box The setup information file of the corresponding station is output to the path specified 6 Reading from the file one corresponding station Select Read File from the menu or click on the Read File in the upper
22. nnnonnnononononononononoanananananannnnnnnnnnnnonnnnanananananan 41 5 A a kk kak an a a e a a e l a ei kk e a A ke a kk an a A ape n ik anatase 44 TOSLINE S20 Loader System for Windows 6F3B0357 1 Introduction This User s Manual describes Toshiba s loader system for the data transmission equipment TOSLINE S20 S20LP S LS for Windows Toshiba has developed different S LS versions for Windows 95 based on the S LS for DOS The two S LS versions meet the TOSLINE S20 for transmission in bus topology hereafter called the TL S20 and the TOSLINE S20LP for transmission in loop topology hereafter called the TL S20LP TOSLINE S20 Loader System for Windows 6F3B0357 2 Before Operation 2 1 What is the S20 Loader The S20 Loader on a personal computer PC monitors station conditions reads writes control data and sets up parameters As shown in the following figure the S20 Loader on a PC connects with TL S20 stations and TL S20LP stations via an RS 232C cable The loader sets up and monitors the station with which the loader is connected local station and other stations being connected via transmission cable remote stations The loader can manage up to 64 stations Transmission cable AETA ae See kaka Be gt Request to local station Request to other stations RS 232C PC IBM PC AT compatible OS Windows 95 lt Recommended environment gt e CPU Pentium or higher O Main memory 24 MB or more O Hard disk
23. on icons appear in the window depending on the station types Setting Information Scan Transmission Information window will appear by double clicking on a station icon ee TOSLINE S20 Loader System for Windows 6F3B0357 4 1 3 Transmission Error One of the following messages boxes will be displayed when an error occurs during the transmission between the TOSLINE S20 Loader System and the TOSLINE S20 Transmit Time Out Receive Time Out Start Code Error End Code Error BCC Error Connection Error Receive Data Length Error RX Text not matched TX Text Transmission is performed in 2 second cycle between the TOSLINE S20 Loader System and the TOSLINE S20 Clicking on the OK button resumes the 2 second cycle transmission when an error occurs TOSLINE S20 Loader System for Windows 6F3B0357 4 1 4 Rearrangement e The Function The display positions order of stations in the Station Connection Diagram window can be changed However this function is limited to the loop topology e Window Image File an Menu M En Window WO Help H ala fin ait Station Station Na DT m Station Connections gt CDE e e e ie je on Em in iu l ie le a ie a ia ia ia ia em e e e ia e oi e De a a la minin ie SE BE BE E e ae le le ea Be le ie la le lie e How to Operate 1 Rearrange the station display positions by inserting the station selected into a desired display position Drag the
24. on when the local station is downed Save Files All Station s Information Saves the setup information of all stations in the file Etnias Terminates the application Menu Setting Information 00 0 0 Displays the Setting Information window Data Access usina Displays the Data Access window RAS Information Online Map ricos Displays the Online Map window Scan Healthy Map cooocnionnncninnnicnincnons Displays the Scan Healthy Map window Loop Map iria in Displays the Loop Map window Station Status 0 eens Displays the Station Status window Station Down Information Displays the Station Down Information RAS Counter Information Displays the RAS Counter Information Online Standby Request Displays the Online Standby Request window Mest Reg est ceinen aa Displays the Test Request window Option Station Display Position Registration ecos Registers the display positions of the stations rearranged Display anata Reflects the display positions of the registered stations in the window Normal iii Displays the stations rearranged in the ascending order of smaller display position numbers Communication Environment Setting Displays the Communication Environment Setting window Window Display Small Size ee Displays the Station Connection Diagram in small size Help Contents conca Displays the Help window Key Word Sear
25. ormal not connected The loop topology version has the following additional items 5 RCVI TX2 status allow inhibit 6 RCV2 TX1 status allow inhibit 7 Loop status Cut off Through End1 2 33 TOSLINE S20 Loader System for Windows 6F3B0357 4 4 5 Station Down Information The Function Reads and displays the down cause of the station being downed This function is used by directly connecting the 20 loader with the station being downed Another station in the network cannot read the status information of the station being downed e Window Image ABI Station Down Information lt Station Down Information gt mo Station Number 1 64 Joo 1 owm Information 60H Hardware Error e Down Messages 1 10H Watch Dog Timer Error 2 20H Memory Bus Error 3 30H SIF malfunction 4 40H Jabber Timeout 5 60H Hardware Error 6 67H SIF Initializing Error 7 77H Receive Buffer Overflow 8 For the unknown code error codes and Undefined Down Code The following message box appears when the station specified is normal Station Down Information a Online Mode Confirm Click OK Button 344 TOSLINE S20 Loader System for Windows 6F3B0357 4 4 6 RAS Counter Information The Function Displays the RAS Counter Information of the corresponding station e Window Image Fi RAS Counter Display e Display Items Network Informat
26. ows 6F3B0357 e How to Operate 1 2 3 4 5 6 Selecting a port to be set up Select a port port 1 port 2 you want to set up on the window The setup information for the port selected appears Setting up individual items information Change individual items information on the window Click on the OK or Update button The data you set is transmitted to the corresponding station Canceling the values after setup Click on the Cancel button The data you set becomes invalid and the Setting Information window disappears Selecting a station Select a station number from the combo box or using the spin button The information of the station selected appears Save in a file one corresponding station Select Save As from the menu or click on the Save As button in upper right corner of the window A dialog box appears for specifying a file name to be saved Set up the path of the file name to be saved in the dialog box The setup information file of the corresponding station is output to the path specified Reading from the file one corresponding station Select Reading File from the menu or click on the Read File button in upper right corner of the window A dialog box appears for specifying a file name to be read Setup the path of the file name to be read in the dialog box The setup information of the corresponding station is read from the file specified for display tr
27. s the loop status of individual stations 4 Station Status Displays the station status of any arbitrary stations 5 Station Down Information Reads the cause of the down from the station downed for display 6 RAS Counter Information Displays the RAS counter information of any arbitrary stations E TOSLINE S20 Loader System for Windows 6F3B0357 4 4 1 Online Map e The Function Displays the connection status of a station which is read in 3 second interval from the station e Window Image line Map r lt Online Map gt O Online Mode O Standby Mode No Mark Offline or No Station O Blue Online mode Dl Red Standby mode e How to Operate Select Online Map from the RAS Information menu The Online Map window appears TOSLINE S20 Loader System for Windows 6F3B0357 4 4 2 Scan Healthy Map e The Function Displays the execution status of scan transmission by the word in the scan area The status is read in 3 seconds cycle for display from the station This function is not found in the TL S20LP loop topology e Window Image an Healthy File F Menu M r lt Scan Healthy Map gt Starting Address pooo Page Up Page Down 0 Scan Data Normal Updating 0 Scan Data Updating Stopped Return gt O Blue Scan data is normally updated Ol Red Scan data is not updated e How to Operate Select Scan Healthy Map from the RAS Inform