Hydropool 2006 Hot Tub Manual.indd
Contents
1. 44 Angle ZOO INN 44 Component Connections Goto Clear 44 Component Configuration Diagram Se aed 37 Repeat gt E AA NAME IE DUE 44 PBC Random Program 44 AM FM CD Player Overview of Controls o ococociccononocicnononocnonononcoronononrorononrorononnorononos 38 LCD TV Remote Control Key 38 Overview of Controls amp Remote Control RR A E 45 General On Screen Menu Language eene 45 Power ONO Postal 39 System Setup Meana 46 Opening amp Closing Front panel sss 39 Input Source 3 39 Programming TV Channels Clock Setting amp Viewing n 39 Auto Program Mode 47 Manual Program 48 Audio Control Adjusting nd rH o GEHE 39 Picture Control ORDER 39 Manual Picture 49 5 39 Auto Picture A 49 Treble Level 39 PSM Picture Status Memo livraison 49 Balance Adjustment ariadna 39 VS TRISTI NR 40 Sound Control Equalizer Balance AVL 5 50 Radio Function
2. 23 Zoom 24 PBC 25 Random 26 Program 27 Repeat 28 A B 42 5 le le 5 5 E E HYDROPOOL self cleaning hot tubs DVD PLAYER CONTROLS SYSTEM SETUP MENU ON SCREEN MENUS AND DISPLAYS OVERVIEW Press the 1 STOP button before proceeding only if a DVD is playing 2 SETUP button to display the main system setup menu 3 CURSOR buttons to navigate the sub menus 4 ENTER button to make selection GENERAL MENU MAIN PAGE GENERAL SETUP SPEAKER SETUP AUDIO SETUP PREFERENCES TV DISPLAY PIC MODE ANGLE MARK OSD LANG GENERAL PAGE NORMAL PS NORMAL LB WIDE TV DISPLAY PIC MODE ANGLE MARK OSD LANG GENERAL PAGE AUTO HI RES N FLICKER CAPTIONS EXIT SETUP SCR SAVER MAIN PAGE GENERAL SETUP GENERAL SETUP SPEAKER SETUP PAGE DOWNMIX LT RT STEREO MAIN PAGE POWER DISPLAY EJECT MUTE ZOOM P N SOURCE OOO SHUFFLE RESUME SUB T ANGLE LOUD SPEAKERS SETUP AUDIO SETUP AUDIO OUT ANALOG A B DYNAMIC MAIN PAGE PROGRAM AUDIO RELATED AUDIO SETUP AUDIO OUT Fut Lale MAIN PAGE DYNAMIC RANGE COMPRESSION 43 CAPTIONS SCR SAVER MAIN PAGE GENERAL SETUP GENERAL PAGE TV DISPLAY PIC MODE ANGLE MARK OSD LANG CAPTIONS SCR SAVER MAIN PAGE ANGLE MARK ON OFF GENERAL PAGE TV DISPLAY PIC MODE ANGLE MARK OSD LANG CAPTIONS SCR SAVE
3. Currently the world is divided into three Standards that are not compatible NISC PAL and SECAM Why are there three Standards or systems Basically television was invented at different times in various parts of the world U S U K and France Politics dictated which system would be employed as the national Standard in these countries At the time these TV Broadcast Systems were established there was no consideration given to the rise of the Global Communications Age in which we live today where information is exchanged electronically as easily as having a conversation with a friend 4 HYDROPOOL self cleaning hot tubs LCD TV CONTROLS MANUAL PROGRAM MODE The Manual program mode allows you to manually tune and arrange the channels in whatever order you choose You can also assign each channel a name with up to 5 characters Press the TV AV button and select TV Press the MENU button Select the Setup menu Select the Manual program menu Press the CH button to select System Press the VOL lt d gt button to select the national broadcast system Europe only BG Germany Austria Sweden Switzerland I UK Hong Kong South Africa DK China Eastern Europe L France 7 Press the CH A F button to select Channel 8 Press the VOL button to select V UHF or Cable as required If possible select the Channel number directly with the NUMBER buttons 9 Press the CH A F button to select
4. Less bright VOL 4 0 100 gt VOL More bright Less colour intensity 0 100 VOL More colour intensity Soft picture VOL 0 100 gt VOL Sharp picture AUTO PICTURE CONTROL The factory presets Dynamic Standard Mild and Game are programmed by the manufacturer and cannot be changed Access these settings through the PSM button PSM Picture Status Memory 1 Press the PSM button repeatedly to cycle through the various presets as follows Dynamic gt Standard gt Mild gt Game User Dynamic vivid picture colour e Standard normal picture colour e Mild softer more muted picture colour e Game external video game picture set up e User manual picture setup 49 HYDROPOOL self cleaning hot tubs LCD TV CONTROLS SOUND CONTROL Sound control allows you to select from several factory preset sound settings Flat Music Movie or Speech The sound settings can also be manually adjusted based on user preference Sound 1 Press the MENU button Equalizer 2 Select the Sound menu 11 3 Press the CH A V button to choose the sound parameter Equalizer Balance AVL or Surround 4 For Balance AVL or Surround press the VOL lt gt button to adjust 5 For Equalizer press the VOL lt button to select AY 4b MENU TV AV and use the CH A F button to select setting Flat Music Movie Speech or User 6 Io manually adjust the Equalizer in the User settings mode i Press the CH A V button t
5. Sound COG oct pecie mite 50 Selecting Band amp Storing 40 SSM Sound Status Memory M 50 Setting Station Presets Automatically 40 Seek amp Manual 40 Other Functions Bal 40 MOTE 51 Preset Station a eene 40 Auto Sleep 51 Local Distance FUNCTION cocccccccccccccccccccccccecccccccccccceccccccccccecscececccccece 40 A 51 ARC Automatic Ratio Control 51 CD Player Function Sleep A 51 Insert Play ont dan 41 _ Changing CD Tracks amp Music 4 Optional Waterproof Remotes Intro Scan Random amp 41 Hydropool Universal Waterproof Remote Overview 52 AM FM CD Ple 53 DVD Player PP 54 Overview of Controls sss 42 A 55 Remote Control Key i elei tci d tad veis 42 System Setup 43 General lover ON OPE eo 44 Screen SAVET A IO O O 44 ij A 44 Input Source elec Nardi 44 e 44 Video Format PAW NI SG coordinarse 44 35 HYDROPOOL self cleaning hot tubs HYDROPOOL SURROUND SOU
6. PROGRAMMING MODE FUNCTION Press then the current mode setting will flash on the display Press then STANDARD MODE The system automatically starts the pump low speed every 30 minutes to measure water temperature and maintain the set temperature The display will show SEd North American Systems 5E European Systems briefly then the last measured water temperature Ihe current water temperature is displayed only after the pump has been operating for at least 2 minutes repeatedly to select mode ECONOMY MODE The system will heat to the set temperature only during the filter cycles The display will show North American Systems Ec European Systems when the temperature is non current When the temperature is current the display will alternate between and the water temperature HYDROPOOL self cleaning hot tubs STANDARD IN ECONOMY MODE FOR NORTH AMERICAN SYSTEMS ONLY While the is in Economy Mode pressing the 2 pad or the pad will cause the system to activate Standard Mode for 1 hour after which the system will revert back to Economy Mode The while in this mode Pressing the display will show 5 then pads during this time will put the system back into Economy Mode immediately SLEEP MODE The system will heat to within 10 C 20 F of the set temperature only during filter cycles The display will show LP North American Systems 5L European Systems until
7. HYDROPOOL self cleaning hot tubs PROGRAMMING FILTER CYCLES To change the factory default filter cycle settings Press then then then within three seconds You will already have advanced to this point if you pressed after completing the SETTING THE SYSTEM CLOCK TIME sequence At this point PROGRAM the display TIME will appear on To set the hour Press or each press changes the time by 1 hour Press to enter and to continue to set minutes To set minutes Press or each press changes the time by 5 minutes Press to enter and to proceed PROGRAM FILTER At this point the display and END TIME will appear To set the hour Press or each press changes the time by 1 hour Press to enter and to continue to set minutes To set minutes Press or each press changes the time by 5 minutes Press to enter and to proceed PROGRAM FILTER At this point on the display START TIME will appear Adjust time as above Press to enter and to proceed pon PRL At this point the display OGRAM FILTER and END TIME will appear Adjust time as above Press the pad again to enter the filter cycle times into the system and exit programming mode The F1 light on the left side of the topside control panel will illuminate to indicate that the system is in Filter 1 cycle The F2 light on the left side of the topside control panel will illuminate to indicate that the system i
8. lights within 1 5m 5ft of the unit must protected Consult your electrician or local electrical authority for further details 6 A green colored terminal or a terminal marked G Ground or Grounding is located inside the supply terminal box or compartment reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment 7 At least two lugs marked BONDING LUGS are provided on the external surface or on the inside of the supply terminal box or compartment To reduce the risk of electric shock connect the local common bonding grid in the area of the hot tub to these terminals with an insulated or bare copper conductor not smaller than No 6 AWG Canada Europe No 8 AWG USA 8 All field installed metal components such as rails ladders drains or other similar hardware within 3 m 10 ft of the hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than No 6 AWG WIRE SIZE NORTH AMERICA e The minimum wire size for systems that require a 40A GFCI is 8 3 c w ground also refered to as 8 gauge 4 conductor The minimum wire size for systems that require a 50A or 60 is 6 3 c w ground also refered to as 6 gauge 4 conductor EUROPE The minimum wire size for European system
9. wet end referred to as an air lock is released allowing the pump to move water efficiently through the plumbing system and to the jets 20 PUMP PRIMING MODE As soon as PRIMING MODE 15 indicated on the topside panel push the left zz to start Pump 1 in low speed then again to switch to high speed Push the 2 pad and right 2 pad to start Flashing Pump 2 and Pump 3 respectively Titanium Series only These are both single speed high only All of the pumps will now be operating in high speed to facilitate priming See FILLING CHECKING AND STARTING YOUR HOT TUB p 15 for complete instructions on pump priming M f PRIMI TAKES v5 MIN STANDARD Pump Icon s Once pump priming has been successfully completed press the 2 pads to turn off the pumps Next manually exit PRIMING MODE by pressing either the 45 pad or the Y pad If you do not manually exit Priming Mode it will automatically terminate after 4 to 5 minutes Be sure that the pumps have been primed before exiting this mode TEMPERATURE CONTROL FUNCTIONALITY AND ADJUSTMENT After you manually exit or the system automatically exits PRIMING MODE your hot tub will automatically heat to the factory preset default temperature of 38 C 100 F The topside panel will briefly show the default temperature and then the display will appear as follows Note that the water temperature is no
10. 104 F in 1 increments SPECIAL NOTE FOR EUROPEAN SYSTEMS Heater works only on pump 1 low speed and turns off whenever another pump is activated exception 3 Phase installations PUMPS JETS FUNCTION 2 left to right on topside control P1 P2 P3 Titanium series only 1 1 151 press turns on low speed the P1 icon spins slowly the P1 icon 5 spins faster no icon displayed when P1 is off press turns on high speed 3rd press turns off pump When low is already operating the 1 press of the P1 2 pad puts the pump directly into high speed low speed P1 starts automatically every 30 minutes to measure water temperature in STANDARD Mode only see MODE FUNCTION when a filter cycle is activated or when a freeze condition is detected When P2 P3 or the blower is manually activated P1 low speed is automatically activated and operates until the pump s or blower time out If P2 or the blower is turned on even briefly and then turned back off P1 low will operate for a minimum of 2 minutes jc d 2 P2 1St press turns on high speed the P2 icon ne Spins fast no icon displayed when P2 is off i el 3 TITANIUM SERIES ONLY press turns on high speed the icon 52 spins fast no icon displayed when P3 is off press turns off pump 210 press turns off pump 21 PUMPS AUTOMATIC TIME OUT P1 high speed P
11. 5 C DO NOT ENTER WATER Remove cover and allow water to cool At 107 spa should automatically reset If spa does not reset shut off power and call your dealer POSSIBLE CAUSES OF OVERHEATING e filter cycle too long or overlapping pump running for extended periods of time e isolation gate valves partially closed e extremely hot weather high ambient temperatures e defective sensor wire FREEZE CONI Potential freeze condition detected Pumps and blower will automatically activate when temperature drops to 40 F 4 C regardless of spa mode 5 5n3 Sn1 The high limit temperature sensor is non functional open circuit Spa control system is deactivated Sn3 Ihe water temperature sensor is non functional open circuit Spa control system is deactivated Prr Indicates high limit or water temperature sensor is non functional LH SAA SENSOR A SERVICE ROI Spa has shut down sensor plugged into Sensor A port not working 31 SENSOR 3 SERVICE Spa has shut down sensor plugged into Sensor B port not working 545 SENSOR SYNE are out of balance If topside display alternates between temperature and 5 75 then occurrence may be temporary and will correct itself The spa shuts down completely when the 5 75 message is flashing on the display HEL FLOW LOW A substantial difference in temperature between the sensors has been detected this could indicate
12. Programme edit Language COMPONENT VIDEO S VIDEO PC Language English Deutsch Francais Italiano Espanol AV MENU TV AV HYDROPOOL self cleaning hot tubs LCD TV CONTROLS PROGRAMMING TV CHANNELS Once you have pre programmed available channel broadcast signals into the TV you will be able to use the CH to scan through the various channels or the NUMBER buttons to directly access a particular channel Channel programming can be done using either Auto Program or Manual Program mode AUTO PROGRAM MODE All broadcast signals that are clear enough to be received are stored using this method It is recommended that you use the Auto Program mode for initial set up Press the TV AV button and select TV Press the MENU button Select the Setup menu Select the Auto program menu Press the CH button to select System Press the VOL lt gt button to select the national broadcast system Europe only BG Germany Austria Sweden Switzerland I UK Hong Kong South Africa DK China Eastern Europe L France 7 Press the CH A button to select Start Press the VOL lt button to start Auto program 9 Once Auto program has completed the screen will automatically return to normal TV mode Auto programme System BG Storage from 1 Start CC MEMORY SLEEP ARC COMPONENT VIDEO S VIDEO PC Aw 4 MENU About National Television Broadcast Standards
13. automatically turn off the blower after 15 minutes IMPORTANT NOTE For systems connected to a 16A electrical supply service pump 2 and blower cannot operate simultaneously OZONATOR OPTIONAL The ozonator operates during FILTER CYCLES and CLEAN UP CYCLES only The display will show the 03 icon while the ozonator is operating FREEZE PROTECTION If the temperature sensor detects a drop to 7 C 44 F within the heater chamber the system automatically activates all pumps to provide freeze protection The pumps will operate until the temperature reaches 7 2 C 45 F and then will continue to operate for an additional 4 minutes before returning to normal system mode 30 HYDROPOOL self cleaning hot tubs TOPSIDE PANEL DISPLAY MESSAGES 117171 HTR TEMP solid Overheat Spa has shut down One of the sensors has detected 119 F 48 C at the heater DO NOT ENTER WATER Remove cover and allow water to cool Reset system by pressing any topside control panel pad If spa does not reset shut off power and call your dealer POSSIBLE CAUSES OF OVERHEATING e filter cycle too long or overlapping pump running for extended periods of time e isolation gate valves partially closed e extremely hot weather high ambient temperatures e defective sensor wire Li 5 SPA TEMP ashing ica Spa has shut down One of the sensors has detected that the spa water is 112 F 44
14. be avoided e Turn the main power on at your electrical panel Follow the control instructions for your particular model hot tub to put the pump into low speed see section HYDROPOOL CONTROL SYSTEMS p 17 PUMP PRIMING RELEASING AN AIR LOCK some systems a Pr message will appear on the display indicating that the system is in PUMP PRIMING MODE This mode will last for 4 to 5 minutes before automatically entering the normal operation mode See complete details for your spa in section HYDROPOOL CONTROL SYSTEMS p 17 e f the hot tub pump is located below water level the water should start circulating immediately If the motor works but you do not notice water circulation within the first 15 seconds the pump may require priming due to trapped air referred to as air lock To prime open the hose bib to allow trapped air to escape Close as soon as the water flow from the jets becomes regular If the pumps have not primed after 2 minutes and water is not flowing from the jets DO NOT allow the pumps to continue to run Turn power off at the main house panel or GFCI and try releasing the air again by loosening the union on the discharge side of the pump s while the motor is not running Turn the power back on If the pumps do not prime after 15 seconds sometimes momentarily turning the pump s off and on will help the system to prime note do not do this more than 5 times Important Under NO circumstances should th
15. button is pressed 5 To select only the strongest station signals press the LOCAL button 6 All 18 FM and 12 AM presets can be stored sequentially by pressing the BAND button to enter the next band set i e If you started with FM1 preset buttons pressing the BAND button will step to FM2 and continuing auto programming 2 4 40 SEEK AND MANUAL TUNE 1 Press the TUNE SEEK UP or TUNE SEEK DOWN button once to automatically tune to the next strongest higher or lower station signal auto seek 2 manually tune to a station signal press and hold either TUNE SEEK button for 2 seconds Holding the button down will either increase or decrease through the station frequencies manually 3 When the desired frequency is reached release the TUNE SEEK button The system remains in manual tune for 3 seconds after the last button is released so that you can still fine tune with additional button presses 4 After 3 seconds the system will return to auto seek mode SCAN FUNCTION 1 Select any FM or AM band set and press SCAN to listen to a few seconds of each radio station The display will flash and the system will automatically advance to the next available station signal play that radio station for a few seconds then advance to the next available station etc etc To stop scanning and continue listening to the current station press the SCAN button again 2 he radio remains in scan mode until the SCAN button is pressed a second time o
16. every 30 minutes to measure water temperature in STANDARD Mode only see MODE FUNCTION when a filter cycle is activated or when a freeze condition is detected When P2 P3 or the blower is manually activated P1 low speed is automatically activated and operates until the pump s or blower time out If P2 P3 or the blower is turned on even briefly and then turned back off P1 low will operate for a minimum of 2 minutes PUMP 2 P2 1St press turns high speed the P2 icon ne Spins fast no icon displayed when P2 is off press turns off pump IMPORTANT NOTE For systems connected to a 16A electrical supply service pump 2 and blower cannot operate simultaneously 28 PUMP 3 P3 TITANIUM SERIES ONLY 1St press turns on high speed the icon 2 spins fast 219 press turns off pump no icon displayed when P3 is off PUMPS AUTOMATIC TIME OUT P1 high speed P2 amp P3 15 minutes P1 low speed 4 hours CLEAN UP CYCLES The Clean up Cycle begins 30 minutes after the pump s or blower have been turned off or have automatically timed out P1 low speed and the ozonator optional will operate for one hour SEITING THE SYSTEM CLOCK TIME flashes on the topside control display upon initial start up This reminder will disappear once the clock time Is programmed then to enter programming mode To set the hour Press Or each press changes the time by 1 hour Press to en
17. far more popular choice Some of the reasons include e Limited indoor space e Delivery complications due to door openings stairwells etc e Limited budget indoor installations usually also involve interior home renovations Desire for an outdoor entertainment center e Hot tub is being installed adjacent to an existing or planned swimming pool e Concerns over splashing water inside the home These split and lower profile versions are designed to accommodate narrow doors or shallow stairwells Since the dimension from the seat to the top of the lip is identical to the regular profile units water submersion for even the tallest user is the same Your Hydropool dealer can even arrange for your hot tub to be shipped without a cabinet or with the cabinet packaged separately for on site installation In many cases the smaller dimensions of a hot tub wit out a cabinet is all that is needed to ensure the hot tub can be delivered without wall or door alterations Where the hot tub is being submerged or a custom deck or tile is being installed the cost savings of being able to order a hot tub without a cabinet is another benefit of choosing Hydropool If you should choose an indoor location you will find further information as outlined in the section SPECIAL CONSIDERATIONS FOR INDOOR INSTALLATIONS For those who choose an outdoor location hot tub operating temperatures can be adjusted to match the season In colder mo
18. hydrotherapy needs Hydropool hot tubs are not only healthful and relaxing they can even add value to your home Please take the time to carefully read and understand all the safety installation and operating instructions in this manual before adding water or electrically connecting your hot tub The following pages contain valuable information and pointers that will save you both time and money as well as help you to simplify upkeep and maintenance Since we manufactured our first hot tub in 1985 the Hydropool team has been dedicated to producing a quality product catering to maximum hydrotherapy comfort energy efficiency and ease of operation We are confident that as you become more familiar with the various safety and maintenance features of your new hot tub you will be satisfied that you made the right decision in purchasing a Hydropool hot tub Happy hot tubbing Dale Papke C E O HYDRO POOL self cleaning hot tubs SAVE THESE INSTRUCTIONS IMPORTANT USER SAFETY INSTRUCTIONS Your physiological response to hot water is very subjective and depends on your age health and medical history If you don t know your tolerance to hot water or if you get a headache or become dizzy or nauseous when using your hot tub get out and cool off immediately WARNINGS 1 Children should NOT use a hot tub without alert adult supervision 2 Children should not enter a hot tub where water temperature exceeds body
19. if possible allow to dry before re installing Hydropool recommends purchasing a second filter so that while the first is cleaning the other is clean and ready to install QUARTERLY 1 Drain hot tub at least once per quarter and clean the acrylic shell surface with a non abrasive cleaner designed specifically for acrylic surfaces see sections CHANGING THE HOT TUB WATER and DRAINING YOUR HOT TUB p 61 CHEMICAL SAFETY HINTS e Never pre mix chemicals with each other prior to adding to hot tub water e Add only one chemical to the water at a time e Always add chemicals to water and not vice versa e Chemicals may be corrosive so handle with care and store in a cool dark place e Never smoke near chemicals as most are flammable e Ensure any spilled chemicals are carefully cleaned up immediately e Always have the POISON CONTROL telephone number handy in the event of an emergency e Keep chemicals out of children s reach e Wear safety glasses and gloves when handling chemicals CLEANING THE SKIMMER BASKET 1 Activate the STANDBY DRAIN ASSIST mode 2 Remove the skimmer basket by pulling the weir door forward and pulling the basket up and towards the front 3 Remove debris from basket Note Avoid hitting the basket against objects to knock debris loose as this may damage the unit 4 Reinsert basket 5 Take the system out of STANDBY DRAIN ASSIST mode and as the pump begins to operate monitor water flow over the weir do
20. misa 14 Safety Hardcover 0 14 Hydropool Exclusive Quick Drain amp Fill diagram 62 Cover Remover 14 Wood Products Filling Checking and Starting your Hot Tub 15 A 63 Pump priming releasing an air lock 15 Protecting your Cabinet Wood Finish 63 Cabinet Wing Locks 2 63 Hydropool Control Systems North American Winterizing your Hydropool Hot 64 Silver amp Gold ica 17 Platinum amp Titanium 20 General 6 65 European What to do in the event of Silver amp Gold 24 Power fluctuations ia 66 Platinum amp Titanium 5 2 4042 2 222 27 Cold weather power failure 66 Topside Control Panel Display Messages 31 HYDROPOOL self cleaning hot tubs On behalf of everyone at the company we thank you for your decision to purchase a Hydropool hot tub Recognized for quality worldwide we are confident that your new hot tub will provide you your family and friends with years of enjoyment and fulfill all your
21. mode Press any topside control pad except for P1 to return to normal operation mode Li 57 IE d ANTARI System is operating in STANDARDO mode See operating instructions for complete details Een ECONOMY System is operating in ECONGFY instructions for complete details mode See operating LE System is operating in O IN ECGNG operating instructions for complete details T TOND STANDARD m3 mode See 51 SLEEP System 15 operating in SLEEP mode See operating instructions for complete details L LI LIL If spa water temperature is more than 20 F 7 C cooler than the set temperature the system will automatically activate the heater to provide freeze protection This is a normal function no corrective action is necessary HYDROPOOL self cleaning hot tubs JET AND FEATURE OPERATION gt Air Injector Adjustable Neck Jet Mini Storm Twin Roto Poly Storm Twin Roto indicates a non adjustable jet JET WATER FLOW ADJUSTMENT Your Hydropool hot tub features adjustable water flow on specific hydrotherapy jets To reduce the flow grasp the outer flange of the jet and turn clockwise approximately a 1 4 turn When it hits the stop the jet is considered closed and flow will be restricted To increase the flow from the closed position turn the jet counter clockwise approximately 1 4 turn When it hits the stop the jet is open and there is maxi
22. of oxidant biocidal agent and is introduced into the hot tub water via a brominator Recommended bromine residual level is 3 0 to 5 0 ppm 4 TWO PART BROMINE composed of a liquid or powder component introduced manually into the water on a weekly basis and a granular component that is added daily or as the hot tub 15 used 5 BROMAMINES are formed when bromine destroys nitrogen bearing organic matter Unlike chloramines bromamines don t cause eye irritation however when allowed to go unchecked will cause an objectionable odour 6 SHOCK the practice of adding an oxidizing agent to hot tub water to destroy ammonia nitrogenous and organic contaminants chloramines and bromamines 7 pH a logarithmic value expressing the relative acidity or basicity of a substance such as hot tub water as indicated by the hydrogen ion concentration pH is expressed as a number a scale of 0 to 14 where 0 is most acidic 1 to 7 being acidic 7 considered neutral 7 to 14 being basic and 14 being most basic The ideal range for hot tub water is 7 4 to 7 6 ppm 8 pH INCREASER raises the pH level of the water 9 pH DECREASER lowers the pH level of the water 10 TOTAL ALKALINITY TA the amount of carbonate bicarbonate and hydroxide compounds present in the water that determines the ability or capacity of the water to resist change in pH Also known as the buffering capacity 11 ALKALINITY BOOSTER raises the alkalinity 12 CALCIUM HARDNESS th
23. ppm IDEAL MAX Chlorine 1 0 3 0 5 0 10 0 Bromine 2 0 3 0 5 0 10 0 CHEMICAL PH 7 4 7 6 7 8 Total Alkalinity TA 80 120 180 Total Dissolved Solids TDS 1000 2000 3000 Calcium Hardness 200 400 500 1000 National Spa amp Pool Institute recommended levels for residential spas hot tubs Organic 105 57 HYDROPOOL self cleaning hot tubs SIGNS OF IMPROPER WATER BALANCE CLOUDY WATER Cloudy water can be caused by high total dissolved solids TDS thereby requiring full or partial water drainage a low disinfectant level incorrect pH requiring balancing suspended particles necessitating a filter cleaning insufficient filtration time FOAMING Foaming 15 caused by the agitation of total dissolved solids TDS This can be caused by the buildup of too much chemical by products in the spa water people not showering before using the hot tub body lotions etc correct add a small amount of foam eliminator and turn on jets to circulate the water At best this is a temporary remedy as excessive foam Is merely a symptom of improper water balance In extreme cases the water will require draining and the filter will require cleaning SKIN IRRITATION Most skin irritation is caused by too high or too low pH Test and adjust Where irritation continues consult your physician CORONA DISCHARGE OZONE TECHNOLOGY All Hydropool hot tubs are factory prepared to accommodate ozonators The Hydrop
24. receiver Preset buttons 1 6 Front panel release Display Clock set 10 Local 11 Sean 12 Band 13 Tune seek up 14 Tune seek down 15 Disc 16 Auto 17 Disc 18 CD repeat 19 CD random 21 Po 9 8 he 15 4 13 20 Audio 21 CD intro gt A MW IR REMOTE CONTROL KEY Basic functions can be controlled via the AM FM CD player or the IR remote control Power ON OFF Volume Zone 1 4 7 12 Volume Zone 2 not applicable Mute Source Band Tune seek up Tune seek down Auto 10 CD repeat 11 Audio 12 Intro 13 Random 14 Disc not applicable 15 Disc not applicable OOO CU POWER MUTE TUNE INTRO e 02 gt SOURCE AUTO id ee Ed e 9 38 IS El HYDRO POOL self cleaning hot tubs AM FM CD PLAYER CONTROLS GENERAL POWER ON OFF 1 Press the POWER button on system or IR remote once to turn system ON and once to turn system OFF 2 NOTE The radio power must be turned on in order to turn on power to the DVD player and the LCD OPENING AND CLOSING THE FRONT PANEL 1 OPEN Place thumb on the front panel release button and forefinger below the front panel overhang Firmly depress the release button while gently pulling the front panel CLO
25. receiver fitting in the hot tub already installed at the factory Insert the waterfall blade through the front of the special waterfall pillow The front flange of the waterfall blade will be recessed into the front of the pillow If it is not recessed the blade needs to be removed and re inserted through the opposite side of the pillow Push the pillow into the semi circular recess ensuring that the portion of the blade protruding out of the back of the pillow inserts firmly into the waterfall receiver fitting HYDROPOOL self cleaning hot tubs FILTER ICE BUCKET LIDS The filter and ice bucket covers provide that finishing touch to your Hydropool hot tub As the covers are Identical to each other simply place over either opening for a finished appearance MOOD LIGHTING STANDARD MOOD LIGHTING Press the light pad on the topside control to turn the light on and off LED MOOD LIGHTING OPTIONAL FACTORY INSTALLED Press the light pad on the topside control to start the following LED lighting modes Pressing the light pad on off within 3 seconds cycles through the various light shows When the LED lighting is turned off for more than 5 seconds then turned back on the system will resume the last light show Description of Light Shows e Mode 1 Synchronous colour change e Mode 2 Freeze mode freezes on selected colour blend from above mode gives unlimited colour blend selection e Mode 3 solid colour blu
26. temperature HYDROPOOL self cleaning hot tubs STANDARD IN ECONOMY MODE FOR NORTH AMERICAN SYSTEMS ONLY While the system is in Economy Mode pressing the 2 pad or the pad will cause the system to activate Standard Mode for 1 hour after which the system will revert back to Economy Mode The display will show 5E while in this mode Pressing the then pads during this time will put the system back into Economy Mode immediately SLEEP MODE The system will heat to within 10 C 20 F of the set temperature only during filter cycles The display will show SLFP North American Systems 5L European Systems until the mode is changed STANDBY DRAIN ASSIST The standby drain assist feature stops the system from operating automatically allowing for convenient filter cartridge removal and for safe draining of the hot tub The following pads must be pressed within 3 seconds of each other Press then the pad the display will flash 564 functions will turn off but the pump low speed can be activated by pressing the 2 pad to facilitate draining the hot tub the display will show ORN North American Systems B European Systems Press any pad other than the 3 to normal operation See DRAINING YOUR HOT TUB p 61 for detailed instructions MOOD LIGHTING pad to return the system STANDARD MOOD LIGHTING Press the pad on the topside control to turn the light on and off LED
27. temperature 37 C 98 6 F 3 As prolonged immersion in water temperatures in excess of 38 100 F may be injurious to your health we recommend measuring the water temperature with an accurate thermometer before entering the tub We also recommend establishing lower temperatures and shorter use periods for young children and or those users potentially affected by hot temperatures 4 Do not allow children to submerge their under water 5 Do not use a hot tub unless all suction guards are installed to prevent body and hair entrapment Do not sit in front of or on top of the suction fittings or skimmer as this will obstruct proper circulation and may result in personal injury 6 Never operate the hot tub pump at high speed without having all suction and return lines open 7 Always keep the hardcover installed and locked when the hot tub is not in use 8 People using medications and or having any adverse medical history should consult a physician before using a hot tub 9 People with infectious diseases should not use a hot tub 10 Exercise caution when entering or exiting a hot tub Where practical install a safety grab bar or handrail Turn off the jets before entering the hot tub to improve visibility of the steps or flat entry area 11 avoid unconsciousness and possible drowning do not use drugs or alcohol before or during the use of a hot tub 12 Pregnant woman should consult a physician before using a hot tub 13
28. the TUNE SEEK UP or TUNE SEEK DOWN button Random press the RANDOM button to play the CD tracks in a random order and RDM will appear to the left on the display To exit Random Mode press the RANDOM button a second time Repeat press the REPEAT button to repeat playback of the current track and RPT will appear to the left on the display To exit Repeat Mode press the REPEAT button a second time 41 HYDROPOOL self cleaning hot tubs HYDROPOOL SURROUND SOUND DVD PLAYER OVERVIEW OF CONTROLS Power Eject Menu IR receiver 6 15 16 17 2 Source Disc Slot Next Stop Previous 10 Play Pause 11 Video Audio input oe E Gur 12 Reset 13 Cursor buttons 14 Enter 15 Indicator light for DISC 16 Indicator light for AV1 12 9 7 17 Indicator light for AV2 IR REMOTE CONTROL KEY MAP Basic functions can be controlled via the DVD player or IR remote control All advanced functions can only be accessed via the IR remote control 1 Power 2 Eject 3 Mute 6 9 4 Subtitle 5 Angle 6 Display e PLAY JECT 7 Source 8 Setup m 9 PAL NTSC 10 El zA 11 Title 24 SHUFFLE RESUME SUB T ANGLE 12 25 13 Cursor buttons m REPERTA 14 Enter 27 4 15 Slow Fwd Back 28 16 Play 17 Fast Fwd Back 25 52 110 18 Next 19 Stop IE 20 Pause 16 21 0 9 22
29. the mode is changed STANDBY DRAIN ASSIST The standby drain assist feature stops the system from operating automatically allowing for convenient filter cartridge removal and for safe draining of the hot tub The following pads must be pressed within 3 seconds of each other Press then the pad the display will flash 554 All functions will turn off but the pump low speed can be activated by pressing the 2 pad to facilitate draining the hot tub the display will show RN North American Systems B European Systems Press any pad other than the 22 to normal operation See DRAINING YOUR HOT TUB p 61 for detailed Instructions MOOD LIGHTING pad to return the system STANDARD MOOD LIGHTING Press the pad on the topside control to turn the light on and off LED MOOD LIGHTING OPTIONAL FACTORY INSTALLED Press the 0 pad on the topside control to start the selection of LED lighting modes Pressing the pad on off within 3 seconds cycles through the various light shows When the LED lighting is turned off for more than 5 seconds then turned back on the system will resume the last light show For complete description of light shows see MOOD LIGHTING p 14 The system will automatically turn off the mood lighting after 4 hours 26 BLOWER OPTIONAL FACTORY INSTALLED Press this pad to turn the blower on and off The system will automatically turn off the blower aft
30. tubs CHOOSING THE RIGHT LOCATION Your Hydropool hot tub can be installed indoors or out on the ground in the ground or half and half The following information will assist you in choosing the right location for your individual needs When making your decision always remember that hot tubs can be enjoyed year round indoors or out regardless of the climate Many Hydropool owners report that their favourite time to use a hot tub is in the cooler fall and winter months while others praise the enjoyment of using their hot tub in the warmer spring and summer months INDOOR LOCATIONS If members of your family are not cold winter enthusiasts or if your backyard or patio area is not suitable for a hot tub installation then an indoor location for your hot tub may be your best or only choice You may wish to create an exercise spa area in your home or install your hot tub in a glass solarium or four season room adjoining your home Indoor installations not only add a unique look and appeal to your home they provide the privacy and controlled climate to ensure that use and enjoyment of your hot tub Is maximized If you are considering an indoor location Hydropool manufactures certain lower profile models in two pieces referred to as split models that can be easily moved into most tight or difficult access locations and then assembled on site by your authorized Hydropool dealer For a variety of reasons outdoor locations are a
31. your hot tub in the initial year Damage as a result of freezing is not covered by the warranty H HYDRO POOL self cleaning hot tubs GENERAL TROUBLESHOOTING ELECTRICAL MECHANICAL SYMPTOM No Power G F C l Trip No Circulation Jet Surge No Heat Erratic Heat Noisy Motor Digital Top Side No Longer Displays Digital Temperature Display is Erratic or Flashing POSSIBLE REASON S CORRECTIVE ACTION Breaker off at main panel or fuse out Improper wiring Fuse blown in control G F C l tripped Short or ground in system Faulty G F C I Pump is not primed Air in waterline Impeller clogged Valves are closed Water level in spa is too low Skimmer obstructed or closed Water level too low Blockage in lines Suction valve partly closed pressure switch not closing Hi Limit switch tripped Cartridge filter dirty Low water Faulty pressure switch Low Water Faulty sensor Damaged or worn bearings Low voltage Low water level Frozen pump Clogged Impeller Improper connection Electrical brown out Check panel Consult electrician Replace Reset G F C I connected improperly As above call Electrician or Hydropool Dealer Open drain bib Release air Access and clean Open valves Top up water Remove Open Add water Check valves and or strainer Pull valve handle up all the way see TOPSIDE PANEL DISPLAY MESSAGES see TOPSIDE PANEL DISPLAY MESSAGES
32. 2 amp P3 15 minutes P1 low speed 4 hours CLEAN UP CYCLES The Clean up Cycle begins 30 minutes after the pump s or blower have been turned off or have automatically timed out P1 low speed and the ozonator optional will operate for one hour SEINS THE SYSTEM CLOCK TIME 2 flashes on the topside control display upon initial start This reminder will disappear once the clock time Is programmed then to enter programming mode To set the hour Press Or each press changes the time by 1 hour Press to enter and to continue to set minutes To set minutes Press Or each press changes the time by 1 minute Press the pad again to continue to the filter cycle programming mode see below OR Press the 22 pad to exit programming mode During normal operation pressing the the current time for 3 seconds FILTER CYCLES Once the system clock time has been programmed the system will automatically activate P1 low speed to filter the water for 2 hours twice each day During the filter cycle the display will show FILTER 1 or FILTER pad will display FACTORY PRESET DEFAULT FILTER 1 the system automatically activates P1 low to operate from 8 AM to 10 AM The filter 1 LED indicator will light during filter cycle 1 operation FILTER 2 the system automatically activates P1 low to operate from 8 PM to 10 PM The filter 2 LED indicator will light during filter cycle 2 operation
33. 2 minutes After 2 minutes the spa water temperature is determined At this point if the water temperature is lower than the set temperature P1 will continue to run and the Heat indicator light on the Topside Panel will illuminate The heater will operate until the water temperature reaches the set temperature point after which both the heater and Pump 1 low will automatically turn off TO CHECK CHANGE THE SET TEMPERATURE The last measured temperature is constantly 4 Jespaye on the topside panel When this pad is pressed once any time during normal operation the display will show the set temperature for 3 seconds Press this pad a second time to increase or decrease the set temperature To change the direction of the temperature settings ie lower vs raise the temperature allow the display to revert back to the current water temperature then press the 3 3 pad again The temperature can be adjusted from 27 C 80 F to 40 C 104 F in 1 increments HYDROPOOL self cleaning hot tubs PUMP JETS FUNCTION Press this pad to activate the pump 1st press turns on low speed 2nd press turns on high speed 3rd press turns off pump When low speed is already operating the 1st press of the 2 pad puts the pump directly into high speed Low speed starts automatically every 30 minutes to measure water temperature in STANDARD Mode only see MODE FUNCTION when a filter cycle is activated or when a free
34. CE GENERAL OVERVIEW NOTABLE POINTS The reliability and longevity of your hot tub support equipment are directly related to how well water quality is maintained ALWAYS observe and follow the instructions on the chemical container The small volume of water in your hot tub is easily affected by external factors such as oils lotions perspiration and chemicals It is imperative that you give your hot tub regular attention to maintain clean safe and balanced water to prevent premature damage and or failure corrosion calcification to the electrical support equipment Maintaining your hot tub water balance chemistry while simple is extremely important Neglected hot water will allow bacteria to quickly spread The mineral content of hot tub water increases from water evaporation sanitizers and other chemicals If the mineral concentration particularly calcium becomes too high the minerals will literally drop or precipitate out of the water and deposit on the hot tub walls plumbing Jets in the filter and on the heater element It is very important that pH be checked frequently and maintained the recommended range as indicated in the chart WATER BALANCE SUMMARY FOR YOUR HOT TUB p 57 Built in bottom floor cleaner eliminates small debris from settling on the hot tub floor and allows pump assisted quick draining 5 529 e t is also very important that Total Alkalinity the ability of the water to res
35. Clean amp reinstall Top Up Adjust or replace Thermostat probe improperly installed Top Up Incorrectly adjusted pressure switch Adjust Call your Electrician or Hydropool dealer Check supply Up Thaw out Water temperature has exceeded set point 65 Access and clean Unplug cable and re connect Reboot control system Decrease filter cycle HYDRO POOL self cleaning hot tubs GENERAL TROUBLESHOOTING CONTINUED WHAT TO DO IN THE EVENT OF POWER FLUCTUATIONS The power supply into your home 15 for the most part fairly consistent However when local power demand 15 high there is a tendency for the voltage entering your home to drop sometimes significantly or fluctuate This condition is referred to as a brown out Although safeguards have been built into the system to protect against this condition supply voltage may drop low enough if even for a second to cause the system to display a ghost message Should this occur or if the display shows partial messages try resetting the system by turning power to the hot tub off waiting a few minutes then turning power on again If thisdoes not reset the system contact your local dealer or service organization POWER FAILURE OR SYSTEM FAULT DURING COLD WEATHER CONDITIONS If your control system will not reset ie GFCI trips or if your pump will not circulate for any other reason place a low wattage space heate
36. D Player Press the SOURCE button to cycle through available program sources Select AU 1 Note the IV can only be operated using the factory IR remote or the Hydropool Universal IR Remote 36 AM FM CD PLAYER 4 5 6 7 8 9 21 20 1918 171615 14 13 CD PLAYER 6 12 9 7 LCD TV VIDEO 5 LED power indicator OPTIONAL 1 HYDR Vf POOL self cleaning hot tubs HYDROPOOL AUDIO VIDEO COMPONENT CONFIGURATION Video Audio Antenna DVD PLAYER Hydropool Series only lt lt 22 ow a 12VDC to A V components Terminal block POWER SUPPLY 230VA gt O INPUT 37 i X Standard Hydropool Series only 7 Subwoofer Nee Purple Green Antenna receptacle E 1 Base System Y q Hydropool and Serenity Series Left Front Right Front Fi 4 white gray 3 X white blk gray blk P N HYDROPOOL self cleaning hot tubs HYDROPOOL SURROUND SOUND AM FM CD PLAYER OVERVIEW OF CONTROLS Volume control Mute Power ON OFF Source 6 9 IR
37. Do not use a hot tub immediately following strenuous exercise 14 Do not permit or use electric appliances such as light telephone radio or television within 1 5 m 5 ft of this hot tub unless such appliances are rated at 12VDC or less 15 Test the GFCI Ground Fault Circuit Interrupter monthly 16 Post emergency phone numbers for Police Fire Dept and Ambulance at the nearest phone head HYPERTHERMIA Since your hot tub can be set to reach temperatures of 40 C 104 F users should be aware that extended submersion in water that exceeds normal body temperature can lead to hyperthermia The causes symptoms and effects of hyperthermia may be described as follows Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 37 C 98 6 F The symptoms of hyperthermia include drowsiness lethargy and an increase in the internal temperature of the body The effects of hyperthermia include Unawareness of impending hazard e Failure to perceive heat Failure to recognize the need to exit the hot tub Physical inability to exit the hot tub Fetal damage in pregnant woman Unconsciousness resulting in the danger of drowning If you sense any of the symptoms of hyperthermia safely exit the hot tub immediately WARNING THE USE OF ALCOHOL DRUGS OR MEDICATION CAN SIGNIFICANTLY INCREASE THE RISK OF FATAL HYPERTHERMIA HYDROPOOL self cleaning hot
38. HYDROPOOL self cleaning hot tubs 2006 owners manual HYDR f POOL self cleaning hot tubs TABLE OF CONTENTS Letter 3 Jet and Feature Operation Jet Identification CN ainia 33 Important User Safety Instructions FOW AdUSIMEN 2 2 20 2 33 A 4 Removal and 34 AINT 4 Me O 34 Waterfall control 1 34 Choosing the Right location Indoor E 5 Hydropool Surround Sound Audio and Outdoor MON Seoane 5 Audio Video Systems Section optional 35 55 Special Considerations for Hot Tub Water Balance ore EE S 6 General VOIVIBW scsi toe prix etri vpn 56 Outdoor asseruit ie Rev ares tab 6 Glossary of Common Water Maintenance Terms 57 Water Balance Summary for your Hot Tub chart 57 Site Preparation for Signs of Improper Water 58 Above Ground 6 Aum 58 Full or Partial In ground installations 7 Overall 5 7 Suggested Routine Water Maintenance Equipment Accessibility
39. I UU 59 In ground Installations 8 Daily Weekly Monthly Quarterly 59 Remote Equipment 8 Chemical safety 59 Unloading Handling your Hot Tub 8 Cleaning the Skimmer 59 Leveling your Hydropool Hot Tub 9 Cartridge Filter Removal Cleaning Re installation 60 General Installation Instructions 9 Cleaning the Acrylic Surface 60 Important Electrical Safety Instructions 10 G F C 1 R C D Application Guideline amp Wire Size 10 Safety Hard 60 North America G F C I installation diagrams 11 Europe R C D installation diagram 12 Changing your Hot Tub water 61 Installing Accessories Water Softeners 61 PON 13 Filter ice bucket lids 14 Draining your Hot Tub water 61 Mood i TT vat fe
40. ILTER CYCLES To change the factory default filter cycle settings Press then 22 be displayed the current filter cycle duration will Press to configure the filter cycle frequency The display will show both day and night cycles day cycle only m night cycle only Press 3 to select the number of filter cycles For continuous filtration select F12 and din Press z amp MODE FUNCTION A combination of keypads is used to change hot tub operation to either STANDARD or SLEEP mode to exit programming mode and save changes PROGRAMMING MODE FUNCTION Press then the current mode setting will flash on the display Press to cycle though to the desired mode Press to select and confirm the selection STANDARD MODE The system automatically starts the pump low speed every 30 minutes to measure water temperature and maintain the set temperature The display will show 5 amp North American Systems 5E European Systems briefly then the last measured water temperature Ihe current water temperature is displayed only after the pump has been operating for at least 2 minutes ECONOMY MODE The system will heat to the set temperature only during the filter cycles The display will show Ezn North American Systems Ec European Systems when the temperature is non current When the temperature is current the display will alternate between and the water
41. LLING CHECKING AND SIARTING YOUR HOT TUB p 15 for complete instructions on pump priming Once pump priming has been successfully completed press the pad to turn off the pump Next manually exit PRIMING MODE by pressing the pad If you do not manually exit PRIMING MODE it will automatically terminate after 4 to 5 minutes Be sure that the pump is primed before exiting this mode 24 TEMPERATURE CONTROL FUNCTIONALITY AND ADJUSTMENT After you manually exit or the system automatically exits PRIMING MODE your hot tub will automatically heat to the factory preset default temperature of 38 C 100 The topside panel will briefly show the default temperature and then the display will appear as follows yet displayed as the system requires Ed approximately 2 minutes of water flow through the heater to determine temperature This is referred to as polling and is indicated on the display by the icon After 2 minutes the display will show the current measured water temperature ims temperature to the desired setting The Heat indicator light on the Topside Panel will shimmer for 90 seconds indicating that the system 15 not yet heating then will illuminate solidly to indicate that the heater circuit has been energized and the spa water Is being heated Note that the water temperature is not Press the pad to increase the The system automatically activates Pump 1 low speed every 30 minutes for at least
42. MOOD LIGHTING OPTIONAL FACTORY INSTALLED Press the pad on the topside control to start the selection of LED lighting modes Pressing the 0 pad on off within 3 seconds cycles through the various light shows When the LED lighting is turned off for more than 5 seconds then turned back on the system will resume the last light show For complete description of light shows see MOOD LIGHTING p 14 The system will automatically turn off the mood lighting after 4 hours BLOWER OPTIONAL FACTORY INSTALLED Press this pad to turn the blower on and off The system will automatically turn off the blower after 15 minutes PURGE CYCLES BLOWER ONLY The system automatically activates the blower for 30 seconds at the beginning of each filter cycle to introduce fresh sanitized water into these plumbing circuits OZONATOR OPTIONAL The ozonator operates during FILTER CYCLES and CLEAN UP CYCLES only FREEZE PROTECTION If the temperature sensor detects a drop to 7 C 44 F within the heater chamber the system automatically activates the pump to provide freeze protection The pump will operate until the temperature reaches 7 2 C 45 F and then will continue to operate for an additional 4 minutes before returning to normal system mode HYDROPOOL self cleaning hot tubs HYDROPOOL SELF CLEAN SERIES CONTROL SYSTEMS NORTH AMERICA HYDROPOOL SELF CLEAN PLATINUM amp TITANIUM SERIES 3447 se
43. N AIR LOCK p 15 15 16 17 18 19 20 21 t may be necessary to put system into STANDBY DRAIN ASSIST mode in order to remove plug WATER SOFTENERS Never fill a hot tub with water from a water softener as it could adversely effect the water chemistry making it difficult to maintain proper water balance If you live in an area with hard or soft water give careful attention to your Calcium Hardness level Topping up with soft water Is acceptable HOSE BIB P1 GATE VALVE FIGURE 2 HYDROPOOL self cleaning hot tubs HYDROPOOL EXCLUSIVE QUICK DRAIN amp FILL 10 SKIMMER PLUG FILL HOSE DRAIN HOSE GATE VALVE HOSE BIB SKIMMER PRE FILTER CLOSING PUMP 1 RETURN GATE VALVE HYDROPOOL self cleaning hot tubs GAZEBOS If you are mounting or planning to mount a gazebo over the top of your hot tub it is critical to ensure that Hydropool is aware of this as extra supports may be necessary Otherwise it will be necessary for your installer to add the extra supports where required PROTECTING YOUR CABINET WOOD FINISH HYDROPOOL hot tub cabinets are made from Western cedar and are factory stained Once stained cedar weathers well and with proper care will maintain its beauty for many years For a protective translucent finish and to enhance the wood grain beauty Sikkens Cetol 01 077 stain and Sikkens Cetol 23 078 or an equivalent polyurethane or marin
44. ND AUDIO VIDEO SYSTEM QUICK START GUIDE FOR ALL HYDROPOOL HOT TUBS WITH OPTIONAL HYDROPOOL SURROUND SOUND SYSTEMS The following info is a guide to the basic system functions of the HYDROPOOL SURROUND SOUND audio video system package TURNING AM FM CD PLAYER ON OFF Press the POWER button 3 to turn on and off power to the AM FM CD player LISTENING TO THE RADIO e Press the SOURCE button 4 to cycle through available program sources TUNER gt CD gt AU 1 If there is no CD inserted then the CD source will not appear When TUNER 15 selected station frequency will be indicated on the display Use the TUNE SEEK UP button 13 and the TUNE SEEK DOWN button 14 to select station LISTENING TO A CD Open the front panel by pressing down the FRONT PANEL RELEASE button e Insert a CD into the disc slot with the label facing up and close the front panel e The CD plays automatically after loading WATCHING A DVD On the LCD TV e Press the POWER button on the TV remote e Press the TV AV button on the TV remote until VIDEO appears on the screen On the DVD player e Press the POWER button 1 on the front of the DVD player or on the DVD remote e nsert a DVD into the disc slot with the label facing up e DVD playback will begin automatically after the disc is inserted With some DVD discs you will need to press the PLAY button 10 on the DVD player or the remote to begin playback On the AM FM C
45. OD OR CONCRETE DECK O 72777772 ORIGINAL COMPACTED CLEAN EARTH SAND FACTORY INSTALLED BACKFILL PLUMBING lt POURED 4 SLAB SR 960092 660092 9900097 692092 9900709 05709 95708 999070 6 GRAVEL SONO TUBES HYDRO POOL self cleaning hot tubs SITE PREPARATION FOR FULL OR PARTIAL IN GROUND INSTALLATIONS For units being installed fully or partially in the ground the type of support will again vary based on whether or not the tub is being installed in an area with freeze thaw conditions Non freezing climates it is sufficient to ensure that the base of the hole or cavity created for the tub simply has a stable compacted base The side walls do not need to be supported however where the climate permits should you choose to backfill directly against the hot tub a clear sand backfill is suggested Climates where freeze thaw occurs it is necessary that a proper poured concrete base complete with sono tubes be installed as outlined in the section ABOVE GROUND INSTALLATIONS p 6 Areas with a high ground water table the concrete base as well as a concrete or wood retaining wall to hold back the earth is suggested This forms a box or bunker in which the hot tub is placed ALWAYS ensure that there is good drainage via a properly designed French gravel drain system and or a sump pump to prevent ground water flooding damage to the support equipmen
46. R MAIN PAGE SET OSD LANGUAGE GENERAL PAGE TV DISPLAY PIC MODE ANGLE MARK OSD LANG CAPTIONS SCR SAVER MAIN PAGE CLOSED CAPTION GENERAL PAGE TV DISPLAY PIC MODE ANGLE MARK OSD LANG CAPTIONS SCR SAVER MAIN PAGE SCREEN SAVER HYDRO POOL self cleaning hot tubs DVD PLAYER CONTROLS GENERAL POWER ON OFF 1 Press the POWER button on system or IR remote once to turn system ON and once to turn system OFF If there is already a disc in the drive playback will start automatically NOTE Power to the AM FM CD player be ON in order to turn ON the DVD player must SCREEN SAVER 1 If there is no button input detected for 5 minutes the screen saver begins automatically 2 The screen saver can be turned ON OFF in the SETUP menu under Screen Saver INSERT AND EJECT A DVD 1 To insert a DVD insert a DVD into the slot with the label facing up The DVD will be drawn inside the unit DISC LOADING will show on the TV display indicating that a DVD is in the drive Note DVD playback will begin automatically 2 remove a DVD press the EJECT button on the front panel Remove DVD from the drive CAUTION always ensure the component panel door has been securely closed to prevent water intrusion that could cause damage to the system INPUT SOURCE SELECTION 1 Press the SOURCE button to cycle through available input sources Sequence is DISC gt AV1 gt AV2 MUTE 1 Pres
47. SE flip up front panel and press firmly until you hear an audible click Except when changing the CD keep the front panel closed at all times to prevent water intrusion that could cause damage to the system INPUT SOURCE SELECTION 1 Press the SOURCE button to cycle through available input sources Sequence is TUNER gt CD gt AU 1 2 If a CD is not inserted into the CD player that input source will not appear on the display Sequence is TUNER AU 1 CLOCK VIEWING THE CLOCK 1 Press the SET button to toggle the display between clock and radio mode Unit will automatically display clock time whenever radio controls are not being used SEITING THE CLOCK 1 Press and hold the SET button for 2 seconds until the first digit of the time starts flashing 2 Use the TUNE SEEK UP or TUNE SEEK DOWN buttons to adjust the hour Note the AM PM indicator at the left when setting the hour 3 Press SET again to select the minutes Adjust as above 4 Press the SET button one final time to save the input and complete setting time 5 he system will automatically return to clock mode and the time will appear after 3 seconds 39 AUDIO CONTROL ADJUSTING THE VOLUME 1 Controls volume for the AM FM radio CD player and also for the TV and DVD player 2 Rotate VOLUME knob to increase or decrease volume 0 31 3 Current volume setting is momentarily indicated on the display 4 When watching TV or viewing a DVD set the volume level to 15 and
48. Search and press the VOL lt button to commence searching When a channel is found the search will stop 10 Press the CH A F button to select Name then press the VOL lt gt button You can use a blank the numbers 0 9 and the alphabet A 2 11 Press the CH A button to select Storage Select and assign the desired channel number using the VOL 4 button or NUMBER buttons 12 Press the OK button to store your selection Stored will appear on the display to confirm input selection 13 Press the TV AV button to return to normal TV mode OORUN To store another channel repeat steps 7 through 12 CC MEMORY SLEEP ARC COMPONENT VIDEO S VIDEO PC Manual programme System BG Channel V UHF 5 Fine gt gt gt Search 444 Storage 1 4 gt OK MENU IV AV 48 365 HYDROPOOL self cleaning hot tubs LCD TV CONTROLS PICTURE CONTROL Picture control enables you to adjust Contrast Brightness Colour and Sharpness based on user preference MANUAL PICTURE CONTROL 1 Press the MENU button Picture 2 Select the Picture menu Contrast 3 Press the CH button to select parameter Brightness 4 Press the VOL lt button to adjust After adjusting wait Colour a few seconds and the input will be stored automatically Sharpness 5 Press the TV AV button to return to normal TV mode Selected Setting Change More darkness VOL 0 100 gt VOL More Light AV 4 MENU
49. UROPE HYDROPOOL self cleaning hot tubs EUROPE R C D INSTALLATION TYPICAL House Breaker Box GREEN YELLOW Ground BROWN Hot BLUE Neutral Spa System Box BROWN Load BLUE Neutral GREEN YELLOW Ground GREEN YELLOW Ground Ground NOT APPLICABLE IN NORTH AMERICA HYDROPOOL self cleaning hot tubs INSTALLING ACCESSORIES When unpacking your new Hydropool hot tub you will find an accessories bag inside containing pillows e filter and ice bucket covers coloured light lenses not required for units ordered with optional L E D lighting tool for opening the wall fitting to access the light bulb 10 expansion plug hose bib adapter Europe only PILLOWS TUBULAR CORNER WRAP The tubular pillows are a friction fit Simply compress the The corner wrap pillows are pre installed at the factory ends slightly and slide into the semi circular recess above are attached via pin and socket To remove grasp ends the seat or lounger with the Hydropool logo facing out of pillow and pull away from hot tub seat To re install lineup pins on back of pillow to mounting sockets and press firmly Although the pillows are designed to remain in place in the hot tub to extend the life of the pillows remove after each use WATERFALL If you received the optional waterfall package remove the blade from the waterfall
50. WINTER DRAIN PLUGS HYDROPOOL self cleaning hot tubs HYDROPOOL SELF CLEAN SERIES CONTROL SYSTEMS NORTH AMERICA HYDROPOOL SELF CLEAN SILVER amp GOLD SERIES HYDROPOOL Mot tubs INITIAL START UP Before applying voltage to power up your hot tub it is very important that you understand the sequence of events that occur when the system 15 activated in order that the pump can be primed efficiently and damage to the system can be avoided and the system will show 4 sets of numbers succession 100 then 103 then 15 then 240 These numbers represent the current software revision and the system input voltage shown this display will appear This display is Indicating that the system is in PUMP PRIMING MODE This mode will last for 4 to 5 minutes before automatically exiting and entering the normal operation mode You can also manually exit PUMP PRIMING MODE after the pump is primed At initial power up this display will appear After the initial software indicators are While in this mode the heater circuit is disabled to allow the priming process to be completed without the possibility of energizing the heater element during low flow or no flow conditions The system will not automatically activate any of the functions however by pushing the xx pad on the topside control the pump can be manually activated Definition Priming a pump is a term used to desc
51. a flow problem Check water level in spa and add if necessary If water level is okay make sure that pumps are primed and all gate valves are fully opened FLO FLB FL Indicates that system is detecting pressure at the pressure switch when the pump is not operating switch is staying closed POSSIBLE CAUSES static pressure weight of water in plumbing keeping pressure switch closed usually associated with remote equipment location e diaphragm in pressure switch coated with minerals due to improper spa water maintenance FLO FLB FL sting indicates that the system is not detecting pressure at the pressure switch while the pump is operating switch is staying open POSSIBLE CAUSES e water level in hot tub may be too low e isolation gate valves partially closed air lock in pump reducing flow LE LOW FLOW Persistent low flow problem displays on the fifth occurrence of an HfL message within a 24 hour period Heater circuit is deactivated but other spa functions continue to operate normally Check water level in spa and add if necessary If water level is okay make sure that pumps are primed and all gate valves are fully opened Press any topside panel pad to reset HYDROPOOL self cleaning hot tubs TOPSIDE PANEL DISPLAY MESSAGES CONTINUED dr oe MAY HE IRY WILL RETEST SHORTLY Inadequate water detected in heater chamber Check water level in spa and add if necessary If water level is okay mak
52. anges the time by 5 minutes Press to enter and to proceed PROGRAM FILTEI ER and END At this point the display E will appear on To set the hour Press or each press changes the time by 1 hour Press to enter and to continue to set minutes To set minutes Press or each press changes the time by 5 minutes Press to enter and to proceed At this point PROGRAM FILTER on the display 2 will appear Adjust time as above Press to enter and to proceed At this point PROGRAM FILTER 2 and END the display TIME will appear on Adjust time as above Press the pad again to enter the filter cycle times into the system and exit programming mode The F1 light on the left side of the topside control panel will illuminate to indicate that the system is in Filter 1 cycle The F2 light on the left side of the topside control panel will illuminate to indicate that the system is in Filter 2 cycle PURGE CYCLES The system automatically activates P2 amp P3 for 5 minutes and the blower for 30 seconds at the beginning of each filter cycle to introduce fresh sanitized water into these plumbing circuits MODE FUNCTION X J This pad is used to change hot tub operation to either Sud or SLEEP mode Press X to enter mode programming and press to select ds desired mode The LCD will flash until 4 is pressed again to confirm the selection STANDARD MODE The sys
53. atistical disc information during playback chapter time remaining counter etc 2 litle press the TITLE button on the IR remote to display the DVD disc title not available on all DVD discs 3 Subtitle press the SUBTITLE button on the IR remote to turn on off subtitle and or to select subtitle language on DVD discs with multilingual subtitle options ANGLE ZOOM 1 Press the ANGLE button on the IR remote to change the view angle only available on DVDs that have the multi angle feature 2 Press the ZOOM button on the IR remote to increase the size of the picture Note that in ZOOM mode only the enlarged part of the picture will be viewable the entire picture will not be visible GOTO CLEAR 1 Press the GOTO button to select DVD playback chapter using the 0 9 number buttons 2 Press the CLEAR button to clear a number that was entered in error REPEAT A B 1 Press the REPEAT button on the IR remote to select either repeat chapter in current view or repeat title On screen sequence is CHAPTER REPEAT ON gt TITLE REPEAT ON gt REPEAT OFF 2 Press the A button on the IR remote to select and repeat a particular scene or passage On screen sequence is ATO B SET A gt A TO B SET B gt A TO B CANCELLED PBC RANDOM PROGRAM VIDEO CD only 1 Video CDs with PBC playback control can be played with or without a menu On the IR remote press the PBC button to select 2 Press the RANDOM button on the IR remote to p
54. cket TO RE INSTALL Push the jet into the socket until it snaps into place ensuring the square pin on the back of the jet lines up with the groove in the socket flange DIVERTER VALVE When your HYDROPOOL hot tub is equipped with a diverter valve it allows you to direct the flow of the water so that it increases the power of the jets on the CAPTAINS CHAIR or on the LOUNGER or a combination of the two Simply turn the valve left or right Always return the valve handle to the middle position before exiting the hot tub to ensure that there is air and water flow to the ozone jet and ice bucket filter niche drains for proper performance WATERFALL CONTROL OPTIONAL If your hot tub was ordered with the optional waterfall feature then you will have a waterfall flow control valve The waterfall feature was designed to provide a gentle cascade of water over the neck and shoulder area Simply turn the top of the control clockwise for more water flow and counterclockwise for less water flow F gne loud 2 CHOEGE ee amm s a E 34 A HYDROPOOL self cleaning hot tubs HYDROPOOL SURROUND SOUND AUDIO amp AUDIO VIDEO SYSTEMS Quick Start Guide DVD Player Function Listening to the cad O eee ee ee 36 Play WORT 44 dnb CO Me 36 Fast Fwd Back Next PreviouS assistant 44 ate HIG aD VD asiatico 36 Display
55. e e Mode 4 solid colour green e Mode 5 solid colour red e Mode 6 solid white simulated For systems with optional Galaxy light package Mode 7 Galaxy lights OFF interior lights ON e Mode 8 Galaxy lights ON interior lights OFF CHANGING BULBS amp LENSES The coloured light lenses supplied with your hot tub not required for units with optional LED lighting simply push over the existing clear light lens SAFETY HARDCOVER LOCKS The safety hard cover is designed to open away from the control area however if the hot tub is symmetrical in dimension the cover can be oriented to open in either direction Simply place the cover on the hot tub pull the straps down so that they are fully extended then release slightly so that there is approximately 6 mm 1 4 in of slack Mark the position on the cabinet and fasten the receiver clip with the screws provided Always ensure the safety hard cover is in place and locked whenever the hot tub is not being used OPTIONAL COVER REMOVER Hydropool offers several different devices to assist in the removal of the safety hard cover Please refer to the instructions supplied with your particular cover remover for installation For further information contact your local Hydropool dealer 14 HYDROPOOL self cleaning hot tubs FILLING CHECKING AND STARTING YOUR HOT TUB Although your hot tub was thoroughly water tested in the factory some loosening of fittings can occur du
56. e varathane with UV inhibitors is highly recommended These protective finishes stabilize the wood grain and build a durable breathable water repellent barrier between the wood surface and the elements These products are available from your local building supply center CABINET WING LOCKS The high quality wing locks provided on your Hydropool Hot Tub cabinet not only firmly secure the equipment access panel they also serve as convenient handles for removal and replacement In order to maintain optimum performance and extended life Hydropool recommends lubricating twice annually with a silicone based lubricant RECOMMENDED PRODUCT Super Lube silicone based lubricant or equivalent Available at major retailers CAUTION Do not use a petroleum based lubricant as this will cause premature deterioration of the lock seal 63 LUBRICATION POINT HYDROPOOL self cleaning hot tubs WINTERIZING YOUR HYDROPOOL HOT TUB In the event that you do not wish to use your hot tub year round it is very important that you properly winterize to protect against damage from freezing Your HYDROPOOL dealer can perform such a service for a nominal fee If you choose to winterize your hot tub yourself please follow the directions outlined below Drain the hot tub entirely see section DRAINING YOUR HOT TUB p 54 Remove and clean the cartridge filter element see section CARTRIDGE FILTER p 53 Using a wet dry utility vacuum remove
57. e calcium portion of the total alkalinity which represents 70 to 75 of total hardness Calcium concentrations determine whether water 15 soft too little calcium or hard too much calcium 13 CALCIUM BOOSTER increases the calcium level 14 TOTAL DISSOLVED SOLIDS TDS a measure of the total amount of dissolved matter in the water calcium carbonates bicarbonates magnesium metallic compounds etc 15 SEQUESTERANTS STAIN AND SCALE CONTROLLERS keeps dissolved metals and minerals in the water from attacking the hot tub shell and support equipment components 16 DEFOAMER removes foam build up from the water surface At best this is a temporary remedy as excessive foam is merely a symptom of improper water balance typically high organic residue and or high pH 17 CARTRIDGE FILTER CLEANER degreases and cleans cartridge filters 18 OZONATOR generates Ozone a gaseous molecule composed of 3 atoms of oxygen and is injected into the hot tub water for the oxidation of water contaminants 19 TEST used to monitor specific chemical residual or demands in the water May in the form of litmus strips or liquid drops 20 PPM abbreviation for parts per million the unit of measurement used in chemical testing which indicates the parts by weight in relation to one million parts by weight of water Essentially identical to the term mg L milligrams per liter WATER BALANCE SUMMARY FOR YOUR HOT TUB SANITIZER
58. e pump s be allowed to operate without priming beyond 5 minutes as this may not only cause unwarrantable damage to the pump it may also cause the control system to go into an overheat condition 0 RING GASKET AT UNION CONNECTIONS RELEASING AN AIR LOCK 5 mm THE MP HOSE BIB WINTER DRAIN PLUGS _ THROUGH THE HYDROP self cleaning h pr th OOL ot tubs If your hot tub is equipped with the optional Remote Above Grade Equipment Package you should close the gate valves on either side of the pump loosen off the lids on the priming pots fill with water re seal turn on the pumps and quickly re open valves Turn the pump onto high speed and re check for leaks The control system will automatically return the pump to low speed after 15 minutes Adjust the hot tub heat control at the topside panel to the desired water temperature Adjust water balance pH TA calcium hardness to recommended levels and add sanitizor The hot tub will require 8 10 hours to reach the desired temperature Keep insulated safety hard cover on the hot tub and the air controls closed during the entire heat up process Definition Priming a pump is a term used to describe the ocess which air trapped in the plumbing and pump wet end referred to as an air lock is released allowing e pump to move water efficiently through the plumbing system and to the Jets
59. e sure that pumps are primed and all gate valves are fully opened Press any topside panel pad to reset dry dry HEATER DRY SERVICE ROD Inadequate water detected in heater chamber displays on third occurrence of a GR message within a 24 hour period The spa shuts down completely when the GRY message 15 flashing on the display Check water level in spa and add if necessary If water level is okay make sure that pumps are primed and all gate valves are fully opened Press any topside panel pad to reset Pr PRIMING TAKES M MIN Priming mode occurs when spa 15 first powered up or when power has been restored after a power interruption Allows for safe priming of the pumps See M7 operating instructions for complete details Temperature unknown after the pump has been operating for 2 minutes the current water temperature will be displayed Temperature not current while in Economy or Sleep mode n either of these modes the pump may be off for hours in between filter cycles To view the current spa water temperature either switch to Standard mode or turn on the pump for at least 2 minutes 5b4 STANDBY MODE Stops the control system from operating automatically to allow filter cartridge removal Press any topside control pad except for P1 to return to normal operation mode 32 drn RAINING Allows for convenient draining of the spa using the P1 low speed Can only be accessed while in Standby
60. en hose each time you fill or drain the hot tub e Always provide adequate ventilation for the support equipment e Consult your local dealer for further information OUTDOOR INSTALLATIONS e Contact your local building code department to determine if a building permit is necessary and for information on applicable bylaws distance from property lines buildings fencing requirements etc If you are doing any excavating contact your local gas hydro and cable company to ensure that there are no underground lines Locate the hot tub where practical within close distance of a door to the house to maximize potential winter use Ensure that your pump s controls drain valve and thermal probe are easily accessible and protected If possible locate the hot tub where you will enjoy some privacy out of the site of neighbours If this is not possible a partial privacy or wind partition or proper placement of the optional Hydropool cover lifter should provide adequate privacy Hot tub equipment is generally designed for indoor out of the direct elements use When your HYDROPOOL hot tub Is equipped with a factory installed cabinet and installed as per the guidelines of this manual the equipment is adequately protected If the hot tub is shipped without a cabinet your custom cabinet or other structure must be designed to supply protection for the hot tub support equipment from rain snow splash water etc but still designed in a mann
61. enu 3 Press the CH button to select Auto sleep 4 Press the VOL lt button to select ON 5 Press the MENU button to go back to the Main Menu or press the TV AV button to exit and return to normal TV mode BLUE BACK Channels without a programmed broadcast signal appear in blue ARC AUTOMATIC RATIO CONTROL Selects screen ratio mode 4 3 16 9 or ZOOM SLEEP TIMER he sleep timer function automatically switches the set OFF to standby mode after the user selected preset time has elapsed 1 Press the SLEEP button to select the number of minutes 0 10 20 30 60 90 120 180 and 240 The timer will automatically begin countdown from the number of minutes selected To view the remaining sleep time press the SLEEP button once d 120 To cancel the sleep time repeatedly press the SLEEP button until the display disappears 51 HYDROPOOL self cleaning hot tubs HYDROPOOL OPTIONAL WATERPROOF REMOTE OVERVIEW HYDROPOOL self cleaning hot tub LED red light blinks to indicate that the remote control is sending a signal POWER turns on off the selected SETUP use for all factor home entertainment component programming sequences Press TV VCR DVD or CD once to select a component to control GUIDE displays program guide EXIT to exit an on screen menu guide CURSOR ARROWS for navigating menu guide SELECT to choose option INFO displays current channel and program information MENU displays an o
62. er 15 minutes PURGE CYCLES BLOWER ONLY The system automatically activates the blower for 30 seconds at the beginning of each filter cycle to introduce fresh sanitized water into these plumbing circuits OZONATOR OPTIONAL The ozonator operates during FILTER CYCLES and CLEAN UP CYCLES only FREEZE PROTECTION If the temperature sensor detects a drop to 7 C 44 F within the heater chamber the system automatically activates the pump to provide freeze protection The pump will operate until the temperature reaches 7 2 C 45 F and then will continue to operate for an additional 4 minutes before returning to normal system mode HYDROPOOL self cleaning hot tubs HYDROPOOL SELF CLEAN SERIES CONTROL SYSTEMS EUROPE HYDROPOOL SELF CLEAN PLATINUM amp TITANIUM SERIES 44 FY DRO POOE self cleaning hot tubs Titanium 24D 0140 0 5 self dearfing hot tubs Platinum INITIAL START UP Before applying voltage to power up your hot tub it is very important that you understand the sequence of events that occur when the system is activated in order that the pumps can be primed efficiently and damage to the pumps can be avoided At initial power up this display will appear and the system will show 4 sets of numbers in succession ie 100 then 113 then 15 then 240 These numbers represent the current software revision and the system input voltage STANDARD After the initial software indica
63. er to ensure adequate ventilation SITE PREPARATION FOR ABOVE GROUND INSTALLATIONS Where the hot tub is a stand a lone above ground installation to be installed in regions where freeze thaw conditions occur a patio stone or pre formed paver type pad may be sufficient if there is no abutting deck s to be damaged during potential seasonal movement of the ground The drawback to this type of base is that splash water could eventually de stabilize the ground under the pad with the resulting support base shift causing damage to the structure For best results we suggest the installation of a level concrete pad 22777777777727777 WOOD OR CONCRETE DECK FACTORY FOAM INSULATION CONCRETE OR WOOD FACTORY INSTALLED RETAINING PLUMBING OPEN CAVITY POURED 4 SLAB RAL DRAIN 6 GRAVEL Dig out and level the ground 20 30 cm 8 12 in below your desired base level Install 10 15 cm 4 6 in of crushed stone Next install 10 15 cm 4 6 in of poured concrete e Level the concrete and apply a broom type finish We recommend that the pad be made 15 cm 6 in larger than the hot tub on three sides and 1 m 3 ft larger on the side where the access steps and or planters will be installed In regions where freeze thaw occurs or where there will be custom decking abutting the hot tub we recommend the installation of sono tubes beneath the pad to prevent future shifting 2777774 WO
64. feature prevents unauthorized temperature adjustment of the hot tub water When the temperature lock 15 activated all automatic functions will continue to operate normally The following pads must be pressed within 3 seconds of each other to activate the lock then 2 then TEMPERATURE UNLOCK The following pads must be pressed within 3 seconds of each other to deactivate the lock then e then When locked the TL light on the left side of the topside control panel will illuminate Only the topside control panel temperature pads will be deactivated 2 then P1 then P1 TOPSIDE PANEL FULL LOCK The topside panel lock feature prevents unauthorized use of the hot tub controls When the topside control panel lock is activated all automatic functions will continue to operate normally The following pads must be pressed within 3 seconds of each other to activate the lock 22 th TA TOPSIDE PANEL UNLOCK The following pads must be pressed within 3 seconds of each other to deactivate the lock then When locked the PL light on the left side of the topside control panel will illuminate All of the topside control panel pads will be deactivated except for the zz STANDBY DRAIN ASSIST The standby drain assist feature stops the system from operating automatically allowing for convenient filter cartridge removal and for safe draining of the hot tub The following pads must be pressed w
65. ggested This forms a box or bunker in which the hot tub is placed Where the climate permits should you choose to backfill directly against the hot tub clear sand backfill is suggested Install protective waterproof conduit to house any light sensor or topside control cables that could be buried ALWAYS ensure that there is adequate drainage via a properly designed gravel drain system and or a sump pump to prevent ground water flooding damage to the support equipment e Access for future service must be considered at the time of design and installation Difficult access can result in Supplemental service labour charges or damage to your decking CLEAN SAND BACKFILL 6 GRAVEL NATURAL DRAIN STANDARD EQUIPMENT Rainproof vented enclosure required ALLOW APROX 4 FT for SERVICE ACCESS REMOTE EQUIPMENT PLACEMENT Where the support equipment is being located in a remote location the following should be considered e The distance from the hot tub should never exceed 5 m 15 ft of pipe length Piping diameter must be 5 08 cm 2 in with minimal use of elbows All piping should be insulated to minimize heat loss and reduce the risk of freezing Np N N N N S NN NNNNNNNNNNNN WOOD OR CONCRETE DECK 4 94747444441 ORIGINAL COMPACTED CLEAN EARTH FACTORY INSTALLED PLUMBING SAND BACKFILL POURED 4 SLAB SONO TUBES e Equipment s
66. hould be installed at or below water level If it is necessary to install the equipment above grade the purchase of the optional Remote Above Grade Option Package will be required e All control cables should be run through a protective pipe to avoid problems associated with ground settling frost etc e All support equipment MUST be weather protected yet still have adequate ventilation UNLOADING HANDLING YOUR HOT TUB All Hydropool hot tubs are shipped with a protective combination layer of bubble wrap cardboard and plastic film Each hot tub is factory strapped onto a wood skid If your hot tub is to be delivered by your local dealer it will generally arrive on a flat bed truck or low profile trailer Most dealers are equipped with the necessary equipment to maneuver the hot tub from the truck to the dolly or cart that will be used to move your hot tub to the installation location Should your hot tub arrive in a common closed box trailer it may be necessary to arrange with a local towing company for a tilt and load tow truck with a pulley winch system to pull the skid from the larger trailer to the lower profile tow truck flat bed The hot tub can be gently slid off the low profile trailer and positioned on its side on a cart or dolly Most Hydropool models require a clearance width of at least 100 cm 39 in to allow movement of the unit on its side through alley ways fence openings etc Where this is not possible the u
67. hwasher or washing machine RE INSTALLATION 11 Place the cartridge filter back into the filter housing 12 Replace the filter housing lid pushing it down to seat ensuring that the lid o ring does not become twisted 13 Hydropool recomends that the lid o ring be lubricated with a non petroleum based lubricant ie Silicone gel when it becomes dry This will help to prevent twisting and pinching as the lid is installed and significantly increase longevity of the o ring 14 Install the filter lock ring turning clockwise until the lock tab snaps into place 15 Close the air vent bleeder valve 16 Take the system out of STANDBY DRAIN ASSIST mode 17 When the pump starts circulating on low speed it will be necessary to release trapped air in the filter Carefully loosen the vent valve counter clockwise until there is the hissing sound of air escaping Once there is a steady stream of water close the vent valve ensuring that the o ring does not become pinched 60 CLEANING THE ACRYLIC SURFACE The acrylic surface can be cleaned and polished using a soft cloth and acrylic cleaner available at your Hydropool dealer CAUTION Never use an abrasive cleaner SAFETY HARD COVERS When a hot tub is uncovered over 90 of heat is lost from the water surface This evaporation also affects the chemical balance and could create humidity problems indoors HYDROPOOL Safety Hard Covers are engineered for maximum thermal efficiency and appea
68. ically The display will show the current track number and the play time of that track An animated 3 D rotating disc will also show on the display to indicate that a disc is playing To remove a CD open the front panel and press the CD eject button on the inside left of the front panel Remove CD from the drive and close the panel CAUTION listen for an audible click to indicate that the front panel has been securely closed to prevent water intrusion that could cause damage to the system CHANGING CD TRACKS AND MUSIC SEEK 1 NO To advance to the next track press the TUNE SEEK UP button once and the track counter will advance one track When the final track on the CD is reached the next press of the button will return to the first track To fast forward or rewind through tracks press and hold the TUNE SEEK UP or TUNE SEEK DOWN button Releasing the button will stop the process and playback will start from that point in the track To return to the beginning of the current track press the TUNE SEEK DOWN button once at any time during track playback Pressing the TUNE SEEK DOWN button a second time within 1 second will skip back to the previous track INTRO SCAN RANDOM AND REPEAT 1 2 3 Intro Scan press the INTRO button to select Intro Scan Mode and SCN will appear to the left on the display The first 10 seconds of each track on the CD will play To exit Intro Scan Mode press the INTRO button a second time or
69. is 2 5 mm copper wire IMPORTANT NOTES e his guide is for standard installations where the wire run is 15 m 50 ft or less For longer wire runs consult a qualified electrician e his is the rated maximum amperage draw Actual amperage draw will vary based on line voltage and optional features AND READ THIS MANUAL THOROUGHLY BEFORE PROCEEDING G F C I R C D APPLICATION GUIDE FOR HYDROPOOL SELF CLEAN amp SERENITY SERIES 2006 MODELS NORTH AMERICA HYDROPOOL SELF CLEAN SERIES Silver Series Gold Series With blower system and or Audio system option Platinum Series With blower system and or Audio or Audio Video system option Titanium Series Titanium Plus Series With blower system and or Audio or Audio Video system option Limited Edition With blower system and or Audio or Audio Video system option HYDROPOOL SERENITY SERIES Silver Series Gold Series With blower system and or Audio system option Platinum Series With blower system and or Audio system option Special Edition With blower system and or Audio system option EUROPE HYDROPOOL SELF CLEAN amp SERENITY SERIES All models 20A With blower system and or Audio or Audio Video system option 20A HYDROPOOL self cleaning hot tubs NORTH AMERICA GFCI INSTALLATION SIEMENS TYPICAL NOTE THIS The white Neutral wire from the back of the GFCI MUST be connected to an incoming Line Neutral The internal mechanism o the GFCI requires
70. ist a change in pH be maintained in the recommended range as indicated in the chart on the following page e Heater and other component failure due to improperly maintained pH or Total Alkalinity levels will not be covered under warranty e Although there may be two identical hot tub models right next door to each other the maintenance requirements will be different dependant on such factors as bather load frequency of use quantity of bathers different body chemistry sun vs shade temperature For these reasons it is very important to develop proper hot tub water maintenance habits and follow your dealers recommended water maintenance procedures Your Hydropool dealer will advise you as to what method they recommend Surface Cleaning 10096 Filtered Water to Jets in R i 100 of the Hot Tub water is filtered in a 15 MINUTE CYCLE A HYDROPOOL self cleaning hot tubs GLOSSARY OF COMMON WATER MAINTENANCE TERMS 1 CHLORINE in granular liquid or puck tablet form is an oxidant and biocidal agent It is very effective and fast acting Recommended chlorine residual level is 3 0 to 5 0 ppm 2 CHLORAMINES a compound formed when chlorine combines with nitrogen or ammonia present in the water When allowed to go unchecked it causes eye and skin irritation and is indicated by a strong chlorine odour 3 ONE PART BROMINE also available in puck tablet form is another type
71. ithin 3 seconds of each other ess Y then the P2 2 pad and the display will flash Platinum series Titanium series then P1 then P1 y 940 sp Li TRNHOBS All functions will turn off but P1 low speed can be activated by pressing the P1 2 pad to facilitate draining the hot tub and the display will show Platinum series Titanium series m LI DRRINING Pressany padotherthantheP1 2 Jpad toreturnthesystemto normal operation See section DRAINING YOUR HOT TUB p 61 for detailed instructions MOOD LIGHTING STANDARD MOOD LIGHTING Press the 0 pad on the topside control to turn the light on and off LED MOOD LIGHTING OPTIONAL FACTORY INSTALLED Press the 0 pad on the topside control to start the selection of LED lighting modes Pressing the on off within 3 seconds cycles through the various light shows When the LED lighting is turned off for more than 5 seconds then turned back on the system will resume the last light show For complete description of light shows see MOOD LIGHTING p 14 The system will automatically turn off the mood lighting after 4 hours BLOWER OPTIONAL FACTORY INSTALLED o o o o o o 151 press turns on high speed the 52 icon 15 displayed 2nd press turns on low speed the E icon Is displayed 3rd press turns off blower no icon displayed when blower is off The system will
72. lay tracks in random order 3 Press the PROGRAM button to select and program the order in which to play tracks HYDROPOOL self cleaning hot tubs HYDROPOOL SURROUND SOUND LCD TV OVERVIEW OF CONTROLS AND IR REMOTE KEY MAP All functions are accessed with the IR remote control 1 DO FW ON SCREEN MENU LANGUAGE SELECTION The onscreen display language 15 selected as follows i All of the on screen displays will appear in the selected language POWER Turns the from Standby mode and OFF to Standby mode Power is only completely OFF when power to the spa is turned OFF MUTE Turns the sound ON OFF NUMBER buttons Selects TV channels PSM Picture Status Memory Recalls your preferred picture setting SSM Sound Status Memory Recalls your preferred sound setting MENU Displays Main menu through which sub menus are accessed ST SAP Selects Audio mode Stereo SAP and Mono VIEW Returns to previously viewed program TV AV Selects input TV Component Video S Video and PC Note only TV and VIDEO are applicable VOLUME Adjusts sound level Menu navigation cursor CHANNEL Selects TV channels Menu navigation cursor OK Accepts selection CC Closed Captioning MEMORY not applicable SLEEP Sets the sleep timer ARC Automatic screen Ratio Control 4 3 16 9 or ZOOM COMPONENT Selects Component mode not applicable VIDEO Selects Video mode for viewing DVD S VIDEO Selects S Video mode not applicab
73. le PC Selects PC mode not applicable ES 5 le A El El is e 5 8 Language Press the MENU button English Select the Setup menu Deutsch Select the Language menu Frangais Press the CH A F button to select desired language Italiano Press the TV AV button Espa ol AV MENU TV AV 45 HYDROPOOL self cleaning hot tubs LCD TV CONTROLS SYSTEM SETUP MENU ON SCREEN MENUS AND DISPLAYS OVERVIEW Press the MENU button to display the main system setup menu A V button to select sub menus Picture Sound Special Setup A V button again to scroll through list of options in each sub menu lt gt to select and adjust an option MENU button to return to previous menu screen IV AV button to exit all menus DURAN m 2 E 0 N Picture Contrast Brightness Colour Sharpness Main menu Picture Sound Special e e e eo 2 Setup AV 4 MENU AV MENU TV AV Auto programme System BG Storage from 1 Start Sound Equalizer Balance AVL Surround Manual programme System BG Channel V UHF 5 Fine gt gt gt Search gt gt gt Special Storage 1 Input Auto Sleep Blue back avew ARC TV AV 1 00000 2 CC MEMORY SLEEP ARC Setup Auto programme Manual programme
74. lf cleaning hot tubs THY DROPOOE self cleaning hot tubs Platinum INITIAL START UP Before applying voltage to power up your hot tub it is very important that you understand the sequence of events that occur when the system 15 activated in order that the pumps can be primed efficiently and damage to the pumps can be avoided At initial power up this display will appear and the system will show 4 sets of numbers in succession ie 100 then 113 then 15 then 240 These numbers represent the current software revision and the system input voltage STANDARD After the initial software indicators are shown this display will appear This display Is indicating that the system is in PUMP PRIMING MODE This mode will last for 4 to 5 minutes before automatically exiting and entering the normal operation mode You can also manually exit the PUMP PRIMING MODE after the pumps are primed PRIMI TAKES ING MIN SET TIME STANDARD Flashing While this mode the heater circuit is disabled to allow the priming process to be completed without the possibility of energizing the heater element during low flow or no flow conditions The system will not automatically activate any of the functions however by pushing the 4 pads on the topside control the pumps can be manually activated Definition Priming a pump is a term used to describe the process in which air trapped in the plumbing and pump
75. lved solids becomes excessive and 15 usually indicated by gray or dull looking water DRAINING YOUR HOT TUB HYDROPOOL EXCLUSIVE QUICK DRAIN amp FILL OVERVIEW e Requires the use of 2 garden hoses drain hose and fill hose e While first garden hose is draining old water from hot tub e second hose is used to wash down interior surface of the hot tub and for fresh water fill REFER TO FIGURE 1 amp FIGURE 2 1 Locate nearest drain facility shower laundry tub floor drain lawn etc 2 Put the hot tub control system into STANDBY DRAIN ASSIST mode 3 Remove the skimmer basket so that the hole beneath it is accessible and insert the 10 rubber expansion plug provided 4 Attach garden hose to hose bib located on plumbing line beside the hot tub control system 5 Run garden hose to drain location 6 Open hose bib 7 Close 1 return gate valve next to the hose bib this directs the water out the drain hose 8 Activate the low speed pump 9 Monitor the hot tub while it drains 10 Use the second garden hose to wash down interior surface as the hot tub continues to drain A sponge may also be used to wipe down the interior surface IMPORTANT DO NOT USE DETERGENTS the remaining residues will adversely affect water chemistry making it difficult to maintain proper water balance DO NOT USE ABRASIVE CLEANERS damage to the acrylic surface will occur 61 11 To completely flush the old water from the
76. minutes After 2 minutes the spa water temperature Is determined At this point if the water temperature is lower than the set temperature P1 will continue to run and the icon will appear on the display The heater will operate until the water temperature reaches the set temperature point after which both the heater and Pump 1 low will automatically turn off HYDROPOOL self cleaning hot tubs TO CHECK CHANGE THE SET TEMPERATURE The last measured temperature is constantly displayed on the topside control When either of these pads Is pressed once the display will show the set temperature Press either pad a second time to increase or decrease the set temperature After 3 seconds the display will once again show the last measured temperature The temperature can be adjusted from 27 C 80 F to 40 C 104 F 1 increments IMPORTANT NOTE Heater works only on pump 1 low speed and turns off whenever another pump is activated exception 3 Phase installations PUMPS JETS FUNCTION 2 from left to right on topside control P1 P2 P3 Titanium series only PUMP 1 P1 151 press turns on low speed the P1 icon spins slowly the P1 icon 5 spins faster no icon displayed when P1 is off 2d press turns on high speed 3rd press turns off pump When P1 low is already operating the qst press of the P1 zg pad puts the pump directly into high speed Low speed P1 starts automatically
77. mum jet flow Do not attempt to turn the jet past the stop as this will unthread the jet internal from the socket JET AIR FLOW ADJUSTMENT Your Hydropool hot tub features adjustable air flow on specific hydrotherapy jets To reduce the flow turn the handle on the air control clockwise When it hits the stop the air is closed and air flow will be restricted To increase the flow turn the handle on the air control counter clockwise When it hits the stop the air control is fully opened For maximum operating efficiency the air controls must remain closed when your hot tub is not use Ozone Jet Hydropool Series Poly Storm Directional 33 Directonal Cluster Mini Storm Directional Power Storm Massage Power Storm Twin Roto All Hydropool hot tubs are shipped from the factory with the jets in the open position INTERCHANGING JET INSERTS A great feature for custom tailoring the Jets in your Hydropool hot tub to suit your personal hydrotherapy needs Jets of like size and dimension may be interchanged with each other for example if you wished to swap a standard pulsator jet for a standard adjustable blaster jet or a medium pulsator jet for a medium adjustable jet HYDROPOOL self cleaning hot tubs JET INSERT REMOVAL amp REPLACEMENT POLY MINI STORM DIRECTIONAL amp TWIN ROTO POWER STORM MASSAGE amp TWIN ROTO TO REMOVE e Turn the jet conter clockwise to unclip amp pull out of so
78. n screen menu VOL controls sound volume CH selects channel MUTE turns sound off on LAST recalls the last channel also used to page back one screen in the main menu Controls available spa functions FIBER 2 Keypad directly selects channels Mode switches between DVD and TV and will also control input select feature on most TV models Enter press once to enter selection REW PLAY FF REC STOP and PAUSE used to control CD and DVD functions 52 HYDROPOOL self cleaning hot tubs HYDROPOOL AM FM CD PLAYER OPTIONAL WATERPROOF REMOTE FUNCTION CROSS REFERENCE STANDARD NON WATERPROOF REMOTE HYDROPOOL UNIVERSAL WATERPROOF REMOTE INCLUDED OPTIONAL HYDROPOOL self cleaning hot tub OOOO POWER MUTE TUNE INTRO e C2 C SOURCE AUTO RANDOM 2 2 7 7 BLOWER LIGHT 1 pump2 PUMP FIBER opp FUNCTIONS Power CD Power Volume Control aden si acid aca le P e ca ac oe CER VOL A V Mute Select Enter WG SEC We Nu DE ae FF gt gt Tune seek down REW lt lt PI TD ene gh hh dur mue Ge ah args as ge eee ays ase ae Mode CD lo ETE Play g
79. nths many owners will operate their hot tub in the range of 38 40 101 104 F During warmer months an operating temperature of 36 37 97 99 F will provide a refreshing retreat If you should choose an outdoor location you will find further information as outlined in the section SPECIAL CONSIDERATIONS FOR OUTDOOR INSTALLATIONS HYDROPOOL self cleaning hot tubs SPECIAL CONSIDERATIONS FOR INDOOR INSTALLATIONS When the hot tub 15 to be installed in a small room under 150 ft2 14 m2 we recommend that large units be fully or partially submerged in floor so that it does not dominate the room This is to allow sufficient headroom for entry and exit to and from the hot tub e t is beneficial if the hot tub room is located near wash room and shower facilities e The hot tub room should have a floor drain to handle spillage a window outside exhaust fan or humidistat controlled exhaust fan for ventilation Where this is not practical the use of indoor outdoor carpeting or a tile floor and the opening of a window while the hot tub cover is removed should be sufficient You should not have concerns regarding humidity When the hardcover is installed no humidity will escape During use the small amount of humidity released into the room can be removed with the use of a small dehumidifier e Consider plumbing a fresh water tap nearby and a permanent drain location for the hot tub to eliminate having to use a long gard
80. o select User ii Press the VOL lt button to select a sound frequency band iii Press the CH button to adjust to desired level Iv Repeat steps ii and iii to select and adjust all five sound frequency bands 7 Press the MENU button to return to the preceding menu av MENU TV AV or the TV AV button to exit and return to normal TV mode a on N AVL when switched ON maintains an equal sound volume level when changing between channels stations AUTO SOUND CONTROL The factory presets Flat Music Movie and Speech are programmed by the manufacturer and cannot be changed Access these settings through the SSM button SSM Sound Status Memory 1 Press the SSM button repeatedly to cycle through the various presets as follows Flat gt Music gt Movie Speach gt User 50 AF HYDROPOOL self cleaning hot tubs LCD TV CONTROLS OTHER FUNCTIONS Special Input INPUT MODE Input modes be selected via the TV AV button or directly by ARC pressing the appropriately labeled button TV for normal television viewing VIDEO for viewing a DVD Av lt gt MENU TV AV COMPONENT not applicable S VIDEO not applicable PC not applicable AUTO SLEEP When Auto sleep is set to ON the TV will automatically switch itself OFF to standby mode approximately 10 minutes after the TV channel being viewed stops broadcasting 1 Press the MENU button 2 Select the Special m
81. ool Corona Discharge Ozonator is regarded as the most technologically advanced system on the market allowing longer contact time with the hot tub water resulting in reduced chemical consumption and clearer cleaner water HOT TUB WATER CD OZONATOR MAZZEI OZONE INJECTOR OZONE MIXING CHAMBER OZONE LN INJECTOR JET Y Hydropool s unique ozone injection system both maximizes the THE BENEFITS ARE e Better water quality Less Chemical Purchases Less water maintenance A more pleasant hot tub experience ry dispersion of the ozone gas and decreases the bubble size resulting in longer contact with the water and increased water quality and purity The ozone water mixture is sent down a series of tubes where the ozone is broken down into even smaller bubbles before being re mixed with the water reducing the off gassing commonly found with other ozone systems HYDROPOOL self cleaning hot tubs SUGGESTED ROUTINE WATER MAINTENANCE ALWAYS FOLLOW THE INSTRUCTIONS ON THE LABEL OF THE CHEMICAL CONTAINER TO DETERMINE THE CORRECT RATIOS INITIAL FILL 1 Make sure the hot tub water is circulating 2 Add a sequesterant stain and scale controller Allow water to circulate for an hour before adding anything else to the hot tub water 3 Add a Shock oxidizing agent 4 Add sanitizing tablets Bromine or Chlorine to the dispenser e Built in dispenser if your Hydropool hot tub was ordered
82. or to assure that it is free floating HYDR POOL self cleaning hot tubs CARTRIDGE FILTER The cartridge should be cleaned every two to four weeks depending on the amount of use Signs that the filter requires cleaning include Reduced jet power e Hazy gray water Rattling noise in the pump or filter Heater not working REMOVAL 1 Activate the STANDBY DRAIN ASSIST mode 2 Remove the cosmetic lid and open the small black air vent bleeder valve on the top of the filter lid 3 Press down the lock tab to disengage and turn the locking ring counter clockwise 4 Pull the filter lid upwards and lift the cartridge element Straight up and out of filter housing CLEANING 5 With a garden hose and spray nozzle hose off the cartridge element ensuring to carefully separate every pleat 6 To remove collected lotions body oils etc soak the cartridge in warm water and a filter cleaning emulsifying compound available at your HYDROPOOL dealer 7 A cleaning cylinder may be purchased from your HYDROPOOL Hot tub dealer 8 Rinse thoroughly and dry before replacing 9 Hydropool recomends purchasing a spare filter cartridge so that you always have a clean substitute ready to rotate 10 After the element has dried if necessary lightly brush between pleats with a fine paint brush to remove remaining dirt particles CAUTION Do not use a wire brush or other devise to clean cartridge element Do not put in dis
83. ows When the LED lighting is turned off for more than 5 seconds then turned back on the system will resume the last light show For complete description of light shows see MOOD LIGHTING p 14 The system will automatically turn off the mood lighting after 4 hours BLOWER OPTIONAL FACTORY INSTALLED st press turns on high speed the icon 15 displayed 2nd press turns on low speed the E icon is displayed 3rd press turns off blower no icon displayed when blower is off he system will automatically turn off the blower after 15 minutes OZONATOR OPTIONAL The ozonator operates during FILTER CYCLES and CLEAN UP CYCLES only The display will show the 03 icon while the ozonator is operating FREEZE PROTECTION If the temperature sensor detects a drop to 7 C 44 F within the heater chamber the system automatically activates all pumps to provide freeze protection The pumps will operate until the temperature reaches 7 2 C 45 F and then will continue to operate for an additional 4 minutes before returning to normal system mode HYDROPOOL self cleaning hot tubs HYDROPOOL SELF CLEAN SERIES CONTROL SYSTEMS EUROPE HYDROPOOL SELF CLEAN SILVER amp GOLD SERIES HYDROPOOL self cleaning hot tabs INITIAL START UP Before applying voltage to power up your hot tub it is very important that you understand the sequence of events that occur when the system is activated in orde
84. plumbing lines allow fresh water to fill into the foot well area while the old water continues to be pumped out Always keep at least 10cm 4 in of water in the foot well so that pump 1 remains primed 12 When the water from the drain hose turns clear indicating fresh fill water flush is complete 13 Turn OFF the low speed pump 14 Close the drain hose bib on the hot tub plumbing line and continue filling hot tub with fresh water Place cover on hot tub to avoid splash out Open pump 1 return gate valve Press any button on the topside control panel other than the pump 1 button to take the system out of STANDBY DRAIN ASSIST mode Pump 1 low speed and the heater will activate to circulate and heat the water while filling continues This also reduces the possibility of an airlock occuring Continue adding fresh fill water until level is approximately 19mm 3 4 in from the top of the skimmer opening Once fill is complete remove the 10 rubber expansion plug from the bottom of the skimmer housing If the filter housing was opened to replace the cartridge filter it will be nessesary to release trapped air from the filter housing by carefully loosening the small black air vent valve located on the top of the filter housing When water begins to escape close the air vent valve In the unlikely event of a pump air lock pump 1 is operating but there is no water movement from the jets refer to section PUMP PRIMING RELEASING A
85. port equipment d Decking should be constructed to allow repair access around the entire hot tub e In remote equipment or no cabinet installations you may add extra insulation but the equipment area must have adequate cross flow ventilation 7 Installation of a safety grab rail or reachable support for use when entering or exiting the hot tub is recommended 8 The hot tub equipment and all electrical plugs outlets and lights within 1 5m 5ft of the unit must be G F C I protected Consult your electrician or local electrical authority for further details 9 Access to the hot tub must always be secured Outdoors in accordance with local property by laws and or via an approved fence with a self closing gate and a safety hardcover Indoors by a lockable door and a safety hardcover 10A nearby garden hose connection is recommended for filling and topping up the hot tub d Q HYDRO POOL self cleaning hot tubs IMPORTANT ELECTRICAL SAFETY INSTRUCTIONS SAFETY COMES FIRST WHEN INSTALLING amp USING THIS ELECTRICAL EQUIPMENT BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED 1 READ AND FOLLOW ALL INSTRUCTIONS 2 Electrical installation must be performed by qualified persons only electrician or equivalent 3 Connect only to a dedicated circuit protected by a class A two pole ground fault circuit interrupter GFCI 4 Use copper conductors only 5 The hot tub equipment and all electrical plugs outlets
86. quipment is mounted on a raised base or platform to prevent water damage to the motor equipment or controls Ensure that any opening to the equipment and the working area around the equipment is large enough to accommodate a service person Whenever possible install the pump below water level to ensure easy priming Where above grade equipment location is necessary please ensure that your hot tub is equipped with the Remote Above Grade Option Package The equipment should be located as close to the hot tub as possible to maximize jet performance Where you have ordered your hot tub with optional remote equipment ensure that the equipment is not located more than 5 m 15 ft from the hot tub Use only 2 in flex pipe or larger for the pipe runs from the equipment to the hot tub with minimal use of elbows or other pipe restrictions Install protective waterproof conduit to house any applicable cords or line extensions such as the sensor and top side control cables light wires or ozone tubing In climates where freeze thaw occurs we suggest that remote piping be buried below the frost line and that pipe insulation is applied over all pipes that run from the hot tub to the remote equipment to maintain energy efficiency HYDROPOOL self cleaning hot tubs IN GROUND INSTALLATIONS When submerging the hot tub all or part way below ground level a concrete base along with a concrete or wood retaining wall to hold back the earth is su
87. r one of the TUNE SEEK buttons Is pressed PRESET SCAN FUNCTION 1 Select any FM or AM band set and press AUTO to listen to a few seconds of each radio station preset The display will flash the preset station number i e P4 and the system will automatically advance to the next preset station signal play that radio station for a few seconds then advance to the next preset station signal etc etc To stop scanning and continue listening to the current station press the AUTO button again 2 The radio remains in preset scan mode until the AUTO button is pressed a second time or one of the preset buttons is pressed LOCAL DISTANCE FUNCTION 1 Press the LOCAL button to select between local station mode and any station default mode When LOCAL is displayed only the strongest station signals will be selected during SEEK or SCAN mode 2 In the default mode LOCAL not shown on display all usable stations with sufficient signal strength will be selected during SEEK or SCAN mode HYDROPOOL self cleaning hot tubs AM FM CD PLAYER CONTROLS CD PLAYER FUNCTION INSERT PLAY AND EJECT A CD NO To insert a CD open the front panel and insert a CD into the slot with the CD label facing up The CD will be drawn inside the unit Close the front panel The system will automatically switch to the CD source mode and the DISC IN symbol on the display indicates that a CD is in the drive Play CD playback will begin automat
88. r or hair dryer under the cabinet in the equipment area This will delay the risk of freezing while a service appointment is scheduled NOTES 66 HYDROPOOL self cleaning hot tubs NOTES 67 Hydropool Industries 335 Superior Boulevard H Y D H Q P L Mississauga Ontario Canada L5T 2L6 self cleaning hot tubs www hydropoolhottubs com
89. r that the pump can be primed efficiently and damage to the system can be avoided At initial power up this display will appear LILI and the system will show 4 sets of numbers in succession ie 100 then 103 then 15 then 240 These numbers represent the current software revision and the system input voltage shown this display will appear This display is indicating that the system is in PUMP PRIMING MODE This mode will last for 4 to 5 minutes before automatically exiting and entering the normal operation mode You can also manually exit PUMP PRIMING MODE after the pump is primed After the initial software indicators are While in this mode the heater circuit is disabled to allow the priming process to be completed without the possibility of energizing the heater element during low flow or no flow conditions The system will not automatically activate any of the functions however by pushing the pad the topside control the pump can be manually activated Definition Priming a pump is a term used to describe the process in which air trapped in the plumbing and pump wet end referred to as an air lock is released allowing the pump to move water efficiently through the plumbing system and to the jets PUMP PRIMING MODE As soon as PR is indicated on the topside panel push the pad to start Pump 1 in low speed then again to switch to high speed to facilitate priming See FI
90. rance They are hinged in the middle for easier handling and the zip fastener allows the tapered foam inserts to be changed if damaged The skirt of the safety hard cover hugs the lip of the hot tub for a tight fit The handles are placed so that even one person can easily carry a large cover The locks with one part fastened to the deck or skirt prevent small children or animals from entering the hot tub Do not drag the safety hard cover across the hot tub or decking Fold the cover first then lift by the handles Standing on the hardcover could cause the tapered foam inserts to crack which will lead to water absorption NEVER LEAN OR STAND ON YOUR HARDCOVER he cover should be cleaned at least twice a year with a vinyl moisturizer and protector HYDROPOOL self cleaning hot tubs CHANGING THE HOT TUB WATER A hot tub should be drained every 8 12 weeks depending on size and amount of use If your hot tub is used daily or by a large number of bathers the water should be drained more often One method to determine the approximate length of time between water changes 15 to divide the water volume in liters of your hot tub by 13 5 and then divide by the average number of bathers each day Formula 135 Volume of water Average Days in litres daily bathers between water changes EXAMPLE 1000 liters divided by 13 5 divided by 2 37 days The hot tub water must be changed when the amount of disso
91. remaining water from the jet openings filter cartridge housing and footwell Either pour or use a turkey baster where necessary to add potable biodegradable RV antifreeze to areas such as pump wet end jet channels filter housing blower channels DO NOT USE AUTOMOTIVE ANTIFREEZE Add potable RV antifreeze to the holes in the bottom suction drain to prevent any trapped water in the false floor from freezing and damaging the hot tub shell e Turn pump on for only a few seconds to circulate the antifreeze Unthread and disconnect all unions in the support equipment area Remove lowest winter drain plug on pump face plate Repeat for all pumps where applicable WINTER DRAIN PLUGS 64 Cover exposed plumbing connections with plastic bags and duct tape Where practical disconnect hot tub support equipment and store in a dry heated area Install the safety hardcover and cover the entire hot tub witha tarp to prevent premature weathering of the cabinet and the safety hard cover Remove snow build up regularly to prevent damage to the safety hard cover It is assumed that your HYDROPOOL hot tub has been properly installed on a reinforced concrete pad to eliminate lifting of the hot tub due to hydrostatic ground water pressure CAUTION Ifyou are 100 confidentthat your hot tub is properly winterized please consult your authorized HYDROPOOL Hot Tub dealer Caution recommends that an authorized Hydropool Dealer winterize
92. required Simply place the hot tub in the desired location and install as outlined on the following pages IMPORTANT NOTES 1 Do not lift the hot tub by the plumbing you may cause leaks 2 Your hot tub can be installed above grade in the floor or ground or half and half 3 Ensure that your HYDROPOOL hot tub is properly supported by either a level concrete pad or a properly constructed deck capable of supporting 1220 kg m 250 lbs ft 2 If there is a possibility that the pad could shift by freezing thawing ground movement such as in clay regions and or areas with high water tables sono tubes extending below the frost line should be used 4 Decking should be chosen and constructed in a manner that minimizes the chance of slipping or falling 5 Level your hot tub using wood shims where necessary ensuring that the tapered end extends at least 61 cm 24 in under the unit 6 If you do not have a factory installed foamed cabinet it Is assumed that you are building your own custom cabinet tiling or decking Please consider the following a Your HYDROPOOL Hot tub is self supporting on its base The cabinet should be decorative only not for support Never suspend the hot tub from the deck or cabinet b Where the hot tub is not equipped with a factory installed cabinet it is the installing electrician s responsibility to ensure all electrical equipment 15 weather protected c Always provide adequate access for servicing the sup
93. ribe the process in which air trapped in the plumbing and pump wet end referred to as an air lock is released allowing the pump to move water efficiently through the plumbing system and to the jets PUMP PRIMING MODE As soon as PR is indicated on the topside panel push the 2 pad to start Pump 1 in low speed then again to switch to high speed to facilitate priming See FILLING CHECKING AND STARTING YOUR HOT TUB p 15 for complete instructions on pump priming Once pump priming has been successfully completed press the 2 pad to turn off the pump Next manually exit PRIMING MODE by pressing the 4 pad If you do not manually exit PRIMING MODE it will automatically terminate after 4 to 5 minutes Be sure that the pump is primed before exiting this mode TEMPERATURE CONTROL FUNCTIONALITY AND ADJUSTMENT After you manually exit or the system automatically exits PRIMING MODE your hot tub will automatically heat to the factory preset default temperature of 38 C 100 The topside panel will briefly show the default temperature and then the display will appear as follows EL yet displayed as the system requires approximately 2 minutes of water flow through the heater to determine temperature This is referred to as polling and is indicated on the display by the icon After 2 minutes the display will show the current measured water temperature ims i temperature to the desired setting The Hea
94. ring shipping Before any decking tiling or carpeting is completed around the installation fill and operate your hot tub to test for leaks this ensures easy access and inexpensive correction Check all union connections and plumbing for minor leaks In the event of a leak ensure all union connections pump plugs are tight and o rings gaskets are in place GATE VALVES HOSE BIB PROPER WATER When adding water for the first time the hot tub should be filled through the skimmer opening helps to prevent air locks using a standard garden hose turning the tap on slowly to prevent damage to the surface a jerking hose connection e Pull up the handles on the intake and return gate valves handles are pulled up when valves are open and pushed down when valves are closed e Ensure the drain hose bib is closed e Ensure that all jets are open See section JET amp FEATURE OPERATION p 26 e Fill the hot tub to the recommended level approximately 19 mm 3 4 from the top of the skimmer opening e Visually check all union connections pump plugs and plumbing for minor leaks In the event of a leak ensure all union connections and pump plugs are tight and o rings gaskets are in place e Before applying voltage to power up your hot tub it Is very important that you understand the sequence of events that occur when the system is activated in order that the pump can be primed efficiently and damage to the system can
95. ry default R1 to R15 indicates rear fade F1 to F15 indicates left balance 3 Unit will automatically return to volume mode if an input is not detected for 3 seconds RADIO FUNCTION Press the SOURCE button to select Radio mode Station frequency will be displayed SELECTING BAND AND STORING STATION PRESETS Press the BAND button to cycle through the 5 sets of radio bands Sequence is FM1 gt FM2 gt FM3 gt gt AM2 Each band stores up to 6 independent presets for a total of 18 FM and 12 AM presets 2 lo program a preset tune into the desired station press and hold for 2 seconds the numeric button that will be used to store this preset PX where X represents the preset number will be displayed on the bottom right of the display i e P6 If power to the hot tub is interrupted or the reset switch is pressed the station presets will need to be reprogrammed SETTING STATION PRESETS AUTOMATICALLY 1 To automatically program the station presets press a preset button 1 6 the system will start the programming sequence at this preset button first Hold the AUTO button for 2 seconds or until the programming sequence begins 3 The current preset and additional presets up to P6 will be programmed with the next available station signal When the auto preset cycle is complete the unit will remain in preset scan mode see PRESET SCAN FUNCTION and will continue scanning the programmed presets until the AUTO
96. s in Filter 2 cycle 22 PURGE CYCLES The system automatically activates P2 amp P3 for 5 minutes and the blower for 30 seconds at the beginning of each filter cycle to introduce fresh sanitized water into these plumbing circuits MODE FUNCTION X J This pan is used to change hot tub operation to either A or mode Press to enter mode programming and press to select i desired mode The LCD will flash until 3 EST is pressed again to confirm the selection STANDARD MODE The system automatically starts P1 low speed every 30 minutes to measure water temperature and maintain the set temperature The word STANDARD will remain on the display along with the last measured temperature The current water temperature is displayed only after the pump has been operating for at least 2 minutes ECONOMY MODE The system will heat to the set temperature only during the filter cycles The display will show the word 2220 9 STANDARD IN ECONOMY MODE While the system is in Economy Mode pressing any 4 pad or the pad will cause the system to activate Standard Mode for 1 hour after which the system will revert back to Economy Mode Pressing the pad during this time will put the system back into Economy Mode immediately SLEEP MODE The system will heat to within 10 C 20 F of the set temperature only during filter cycles The display will show the word SLEEP LIQUID CRYSTAL DISPLAY LCD Con
97. s the MUTE button on the DVD player IR remote and the word MUTE will appear momentarily on the TV screen to indicate that the DVD audio is in mute mode Press the MUTE button again to exit DVD audio mute mode and the words MUTE will appear momentarily on the screen Note Use of the DVD mute function 15 generally not required as the sound volume is muted through either the LCD TV function or the Radio function PAL NTSC 1 Press the P N button on the IR remote to select the DVD video playback format NTSC North American video format PAL European video format DVD PLAYER FUNCTION PLAY PAUSE FAST FWD BACK NEXT PREVIOUS 1 Play playback begins automatically after disc is inserted In most cases it will go to the DVD root menu and it will be necessary to press the PLAY or ENTER button 2 Pause press the Il button during playback to freeze the picture still mode Press the Il button again to resume playback 44 3 Fast Fwd Back press the gt gt 4 4 button during playback Each time the button is pressed the fast forward back speed changes as follows DVD normal 2x 4x 6x 8x 20x VCD normal 2x 4x 6x 8x 4 Next Previous press the PI button to jump to the next chapter DVD or the next track VCD CD and press the 6 button to jump to the previous chapter or track DISPLAY TITLE SUBTITLE 1 Display press the DISPLAY button on the IR remote to show st
98. se of a crane to lift the hot tub from the truck or trailer over the house to the patio or yard is often a simple and economical option CAUTIONS e Do not move or place the hot tub on the side where the equipment is located as damage could occur e Never roll or flip the hot tub end over end as the cabinet could be damaged e Never lift or handle the hot tub by the plumbing e Make sure that there is sufficient assistance to gently slide the hot tub off the dolly or cart to the support base without any damage HYDROPOOL self cleaning hot tubs UNLOADING HANDLING YOUR HOT TUB continuep LEVELING YOUR HYDROPOOL HOT TUB After the hot tub is properly positioned on the support base the entire unit should be checked with a level and shimmed as necessary Should you find that the support base is sloped or otherwise uneven level your hot tub using TAPERED wood shims where necessary ensuring that the tapered end extends at least 61 cm 24 in under the unit This will insure contact with the support substructure to appropriately distribute the weight of the unit Do not just shim under the cabinet base outside edge as this will cause structural stress on the unit potentially causing unwarrantable damage to the hot tub structure and or shell GENERAL INSTALLATION INSTRUCTIONS Your HYDROPOOL Hot tub is a self contained pre plumbed unit so that no on site plumbing connections to the residential water supply or drain are
99. t un es aco ts a arom Bes ats Brame tes ee Gach Record HYDROPOOL self cleaning hot tubs HYDROPOOL DVD PLAYER OPTIONAL WATERPROOF REMOTE FUNCTION CROSS REFERENCE STANDARD NON WATERPROOF REMOTE HYDROPOOL UNIVERSAL WATERPROOF REMOTE INCLUDED OPTIONAL FUNCTIONS SOUICE ___ _ dc er E E gt Rapid FWD okip NEXT PREV ___ HYDROPOOL self cleaning hot tubs HYDROPOOL LCD TV OPTIONAL WATERPROOF REMOTE FUNCTION CROSS REFERENCE STANDARD NON WATERPROOF REMOTE HYDROPOOL UNIVERSAL WATERPROOF REMOTE INCLUDED OPTIONAL HYDROPOOL self cleaning hot tub CH A CHw CC MEMORY SLEEP ARC COMPONENT VIDEO S VIDEO PC FUNCTIONS C IV Power es RO LUI AU D Em Numbers 0 9 nu Mode EEEE o Menu CH channel UPON denen theese CH A V Menu navigation 150 5 Cursor arrows Select VOL volume UP DN Tm VOL A V Menu navigation CU SOS ansima sire ted qe apnea areas atu Cursor arrows oll Info HYDROPOOL self cleaning hot tubs HOT TUB WATER BALAN
100. t indicator light on the Topside Panel will shimmer for 90 seconds indicating that the system 15 not yet heating then will illuminate solidly to indicate that the heater circuit has been energized and the spa water 15 being heated Note that the water temperature is not Press the pad to increase the The system automatically activates Pump 1 low speed every 30 minutes for at least 2 minutes After 2 minutes the spa water temperature is determined At this point if the water temperature is lower than the set temperature P1 will continue to run and the Heat indicator light on the Topside Panel will illuminate The heater will operate until the water temperature reaches the set temperature point after which both the heater and Pump 1 low will automatically turn off TO CHECK CHANGE THE SET TEMPERATURE The last measured temperature is constantly 4 Jenae on the topside panel When this pad is pressed once any time during normal operation the display will show the set temperature for 3 seconds Press this pad a second time to increase or decrease the set temperature To change the direction of the temperature settings ie lower vs raise the temperature allow the display to revert back to the current water temperature then press the 3 3 pad again The temperature can be adjusted from 27 C 80 F to 40 C 104 F in 1 increments HYDROPOOL self cleaning hot tubs PUMP JETS FUNCTION Press this pad to ac
101. t yet displayed as the system requires approximately 2 minutes of water flow through the heater to determine temperature This is referred to as polling and 15 indicated on the display by the icon After 2 minutes the display will show the current measured water temperature SET TIME STANDARD Flashing Pump 1 Low Speed Icon 3 Press the pad to increase the temperature to the desired setting The icon will appear on the display indicating that the heater has been activated SET TIME STANDARD Flashing Pump 1 Low speed Icon The system automatically activates Pump 1 low speed every 30 minutes for at least 2 minutes After 2 minutes the spa water temperature is determined At this point if the water temperature is lower than the set temperature P1 will continue to run and the icon will appear on the display The heater will operate until the water temperature reaches the set temperature point after which both the heater and Pump 1 low will automatically turn off HYDROPOOL self cleaning hot tubs TO CHECK CHANGE THE SET TEMPERATURE The last measured temperature is constantly displayed on the topside control When either of these pads Is pressed once the display will show the set temperature Press either pad a second time to increase or decrease the set temperature After 3 seconds the display will once again show the last measured temperature The temperature can be adjusted from 27 C 80 F to 40 C
102. t or structure Install protective waterproof pipe to house any light sensor or topside control cables that could be buried Access for future service must be considered at the time of design and installation Difficult access can result in supplemental service labour charges Consider easily removable deck materials OVERALL SUPPORT Your Hydropool hot tub is equipped with a factory installed wood cradle support which helps distribute the weight of the water over the entire foot area of the hot tub The cabinet either factory installed or customized on site should be decorative only and not relied on for overall support Never suspend a hot tub from a deck or floor as the acrylic lip will crack and possibly break off EQUIPMENT ACCESSIBILITY The equipment must be located in an area where it will remain dry and will not be exposed to rain snow or ground water The standard Hydropool hot tub has the equipment installed inside the protective cedar cabinet e When your hot tub is to be installed above ground the cabinet is designed for both protection and accessibility When your hot tub is to be installed fully or partially in the ground if you are relocating the equipment remotely from the hot tub or if you have ordered a hot tub without a cabinet it is necessary that the equipment is installed in an area that is dry protected from the elements has proper ventilation and is easily accessible for service e Always ensure that the e
103. te instructions on pump priming TI MOTE AT NI PRIMI TAKES E STANDARD Pump Icon s Once pump priming has been successfully completed press the pads to turn off the pumps Next manually exit PRIMING MODE by pressing either the pad or the Y pad If you do not manually exit Priming Mode it will automatically terminate after 4 to 5 minutes Be sure that the pumps have been primed before exiting this mode TEMPERATURE CONTROL FUNCTIONALITY AND ADJUSTMENT After you manually exit or the system automatically exits PRIMING MODE your hot tub will automatically heat to the factory preset default temperature of 38 C 100 F The topside panel will briefly show the default temperature and then the display will appear as follows Note that the water temperature is not yet displayed as the system requires approximately 2 minutes of water flow through the heater to determine temperature This is referred to as polling Flashing and 15 indicated on the display by the Pump 1 Low Speed icon 3 icon After 2 minutes the display will show the current measured water temperature SET TIME STANDARD Press the pad to increase the temperature to the desired setting The icon will appear on the display indicating that the heater has been activated SET TIME STANDARD Flashing Pump 1 Low speed Icon The system automatically activates Pump 1 low speed every 30 minutes for at least 2
104. te the lock m qM e n v TOPSIDE PANEL UNLOCK The following pads must be pressed within 3 seconds of each other to deactivate the lock 22 then When locked the PL light on the left side of the topside control panel will illuminate All of the topside control panel pads will be deactivated except for the zz STANDBY DRAIN ASSIST The standby drain assist feature stops the system from operating automatically allowing for convenient filter cartridge removal and for safe draining of the hot tub The following pads must be pressed within 3 seconds of each other ES Y then the P2 3i pad and the display will flash 7 Platinum series Titanium series then P1 J then P1 a Im 2 MANDOS 23 All functions will turn off but P1 low speed can be activated by pressing the 2 pad to facilitate draining the hot tub and the display will show Platinum series Titanium series cy DRRINING Pressany pad otherthantheP1 2 Jpadtoreturnthesystemto normal operation See section DRAINING YOUR HOT TUB p 61 for detailed instructions MOOD LIGHTING STANDARD MOOD LIGHTING Press the pad on the topside control to turn the light on and off LED MOOD LIGHTING OPTIONAL FACTORY INSTALLED Press the 0 pad on the topside control to start the selection of LED lighting modes Pressing the on off within 3 seconds cycles through the various light sh
105. tem automatically starts P1 low speed every 30 minutes to measure water and maintain the set temperature The word STANDARDO will remain on the display along with the last measured temperature The current water temperature Is displayed only after the pump has been operating for at least 2 minutes ECONOMY MODE The system will heat to the set temperature only during the filter cycles The display will show the word ECGNGFIY STANDARD IN ECONOMY MODE While the system is in Economy Mode pressing any 2 pad or the pad will cause the system to activate Standard Mode for 1 hour after which the system will revert back to Economy Mode Pressing the pad during this time will put the system back into Economy Mode immediately SLEEP MODE The system will heat to within 10 C 20 F of the set temperature only during filter cycles The display will show the word SLEEP LIQUID CRYSTAL DISPLAY LCD Continually provides feedback the Operating status of the hot tub Icons indicate various functions and programming information SET TIME STANDARD LCD INVERT This feature inverts the LCD readout for convenient viewing from inside the hot tub To invert the readout Platinum Series press or then Titanium Series press To return the LCD readout to normal viewing from outside of the hot tub repeat 29 HYDROPOOL self cleaning hot tubs TOPSIDE PANEL LOCK FEATURES TEMPERATURE LOCK The temperature lock
106. ter and to continue to set minutes To set minutes Press Or each press changes the time by 1 minute Press the pad again to continue to the filter cycle programming mode see below OR Press the pad to exit programming mode During normal operation pressing the 22 the current time for 3 seconds FILTER CYCLES Once the system clock time has been programmed the system will automatically activate P1 low speed to filter the water for 2 hours twice each day During the filter cycle the display will show FILTER or FILTER 2 ERE pad will display FACTORY PRESET DEFAULT FILTER 1 the system automatically activates P1 low to operate from 8 AM to 10 AM The filter 1 LED indicator will light during filter cycle 1 operation FILTER 2 the system automatically activates P1 low to operate from 8 PM to 10 PM The filter 2 LED indicator will light during filter cycle 2 operation HYDROPOOL self cleaning hot tubs PROGRAMMING FILTER CYCLES To change the factory default filter cycle settings Press then then then within three seconds You will already have advanced to this point if you pressed after completing the SETTING THE SYSTEM CLOCK TIME sequence ROG At this point the display START TIME will appear on To set the hour Press or each press changes the time by 1 hour Press to enter and to continue to set minutes To set minutes Press or each press ch
107. this neutral connection The GFCI will not work without it White Wire Q Line Neutral LOAD LOAD LOAD b POWER NEUTRAL POWER LINE NEUTRAL Qpoeococsoeco From i E EE LINE 2 INPUT ru Electric Service Panel LINE 1 or IMPORTANT NOTE Installation Other of this GFCI Circuit Breaker GROUND Source including ampere sizing and selection of conductor size and type must be GROUND INPUT accomplished by a qualified electrician in accordance with the National Note round bar included Electrical Code or the Canadian must be installed Electrical Code and all federal state banel and local codes and regulations in ee GROUND TO SPA effect at the time of installation To Spa or 120 volts ae LOAD NEUTRAL 240 volts Equipment 120 volts LOAD 1 ES G F C I Breaker Box SQUARE D TYPICAL Front View of 1 Square D House Breaker Box GRN GROUND WHITE NEUTRAL RED HOT BLACK HOT GRN GROUND Spa System Box BLACK RED S WHITE NEUTRAL 2 BLACK HOT 2 2 RED HOT 4 5 2 GREEN GROUND 5 S S GRN GROUND NOT APPLICABLE IN E
108. tinually provides feedback on the Operating status of the hot tub Icons indicate various functions and programming information m TU SET TIME STANDARD LCD INVERT This feature inverts the LCD readout for convenient viewing from inside the hot tub To invert the readout Platinum Series press or then Titanium Series press To return the LCD readout to normal viewing from outside of the hot tub repeat HYDROPOOL self cleaning hot tubs TOPSIDE PANEL LOCK FEATURES TEMPERATURE LOCK The temperature lock feature prevents unauthorized temperature adjustment of the hot tub water When the temperature lock 15 activated all automatic functions will continue to operate normally The following pads must be pressed within 3 seconds of each other to activate the lock then 4 then TEMPERATURE UNLOCK The following pads must be pressed within 3 seconds of each other to deactivate the lock then 2 then When locked the TL light on the left side of the topside control panel will illuminate Only the topside control panel temperature pads will be deactivated 22 then P1 then P1 TOPSIDE PANEL FULL LOCK The topside panel lock feature prevents unauthorized use of the hot tub controls When the topside control panel lock is activated all automatic functions will continue to operate normally The following pads must be pressed within 3 seconds of each other to activa
109. tivate the pump 1st press turns on low speed 2nd press turns on high speed 3rd press turns off pump When low speed is already operating the 1st press of the 2 pad puts the pump directly into high speed Low speed starts automatically every 30 minutes to measure water temperature in STANDARD Mode only see MODE FUNCTION when a filter cycle is activated or when a freeze condition is detected When the blower optional is manually activated the pump low speed is automatically activated and operates until the blower times out If the blower is turned on even briefly and then turned back off low speed will operate for a minimum of 2 minutes PUMP AUTOMATIC TIME OUT High speed 15 minutes Low speed 2 hours CLEAN UP CYCLES The Clean up Cycle begins 30 minutes after the pump or blower have been turned off or have automatically timed out The pump low speed and the ozonator optional will operate for one hour FILTER CYCLES The system will automatically activate the pump low speed to filter the water either once or twice each day and can be programmed by the user The first filter cycle day begins 6 minutes after the spa is initially powered up The second filter cycle night begins 12 hours after the start of the first filter cycle The filter cycle duration length of time the pump low runs is programmable from 1 to 12 hours F1 to F12 The factory default is 2 hours twice daily PROGRAMMING F
110. tors are shown this display will appear This display is indicating that the system is in PUMP PRIMING MODE This mode will last for 4 to 5 minutes before automatically exiting and entering the normal operation mode You can also manually exit the PUMP PRIMING MODE after the pumps are primed PRIMI TAKES ING MODE MIN SET TIME STANDARD Flashing While this mode the heater circuit is disabled to allow the priming process to be completed without the possibility of energizing the heater element during low flow or no flow conditions The system will not automatically activate any of the functions however by pushing the pads on the topside control the pumps can be manually activated Definition Priming a pump is a term used to describe the process in which air trapped in the plumbing and pump wet end referred to as an air lock is released allowing the pump to move water efficiently through the plumbing system and to the jets 27 PUMP PRIMING MODE As soon as PRIMING MODE 15 indicated on the topside panel push the left 2 to start Pump 1 in low speed then again to switch to high speed Push the zg pad and right 22 pad to start Flashing Pump 2 and Pump 3 respectively Titanium Series only These are both single speed high only All of the pumps will now be operating in high speed to facilitate priming See FILLING CHECKING AND STARTING YOUR HOT TUB p 15 for comple
111. use the TV volume to control sound levels MUTE 1 Press the MUTE button once to mute the sound MUTE will flash on the display 2 Press the MUTE button again or rotate the volume knob to resume audio BASS LEVEL 1 Press the AUDIO button until BAS appears on the display 2 Rotate the VOLUME knob to adjust setting C O indicates neutral bass setting factory default 2 to 12 indicates reduced bass 2 to 12 indicates increased bass 3 Unit will automatically return to volume mode if an input is not detected for 3 seconds TREBLE LEVEL 1 Press the AUDIO button until TRE appears on the display 2 Rotate the VOLUME knob to adjust setting indicates neutral treble setting factory default 2 to 12 indicates reduced treble 2 to 12 indicates increased treble 3 Unit will automatically return to volume mode if an input is not detected for 3 seconds BALANCE ADJUSTMENT 1 Press the AUDIO button until BAL appears on the display 2 Rotate the VOLUME knob to adjust setting C O indicates center factory default R1 to R15 indicates right balance L1 to L15 indicates left balance 3 Unit will automatically return to volume mode if an input is not detected for 3 seconds HYDRO POOL self cleaning hot tubs AM FM CD PLAYER CONTROLS FADER ADJUSTMENT 1 Press the AUDIO button until FADE appears on the display 2 Rotate the VOLUME knob to adjust setting C O indicates center facto
112. with the optional built in bromine chlorine dispenser located in the lid of the cartridge filter housing refer to section CARTRIDGE FILTER for details on removing and re installing the lid Once the filter lid is removed you ll notice a clear 2 5 cm 1 diameter tube extend ing from the bottom of the lid Unscrew the check valve assembly at the end of the tube and add 5 or 6 tablets Do not overfill dispenser as performance will be affected Set the dial initially to 5 and allow water to circulate for 3 to 4 hours before testing level Adjust dial more or less as necessary Floating dispenser As above add 6 or 7 tablets adjust initially to 5 allow water to circulate for 3 to 4 hours then test The tablets will dissolve slowly over a 10 14 day period depending on dial setting and use of the hot tub 5 Test pH and Total Alkalinity and adjust accordingly DAILY 1 Test water and if necessary add shock 2 Ensure proper water level is maintained WEEKLY 1 Test pH and Alkalinity Adjust accordingly 2 chemical dispenser 3 Add sequesterant stain and scale controller 4 Remove and spray cartridge filter with garden hose and re install see section CARTRIDGE FILTER p 60 5 Remove and clean out skimmer basket see section CLEANING THE SKIMMER BASKET 6 Add Shock oxidizing agent MONTHLY Soak your filter cartridge in a filter cartridge cleaning solution Rinse thoroughly and
113. ze condition is detected When the blower optional is manually activated the pump low speed is automatically activated and operates until the blower times out If the blower is turned on even briefly and then turned back off low speed will operate for a minimum of 2 minutes PUMP AUTOMATIC TIME OUT High speed 15 minutes Low speed 2 hours CLEAN UP CYCLES The Clean up Cycle begins 30 minutes after the pump or blower have been turned off or have automatically timed out The pump low speed and the ozonator optional will operate for one hour FILTER CYCLES The system will automatically activate the pump low speed to filter the water either once or twice each day and can be programmed by the user The first filter cycle day begins 6 minutes after the spa is initially powered up The second filter cycle night begins 12 hours after the start of the first filter cycle The filter cycle duration length of time the pump low runs is programmable from 1 to 12 hours F1 to F12 The factory default is 2 hours twice daily 25 PROGRAMMING FILTER CYCLES To change the factory default filter cycle settings Press then gt be displayed the current filter cycle duration will Press again to adjust the filter cycle duration Press 2 MODE FUNCTION A combination of keypads is used to change hot tub operation to either STANDARD ECONOMY or SLEEP mode to exit programming mode and save changes
Download Pdf Manuals