Home

Install Manual

image

Contents

1. BODY COMPOSITION ANALYZER Installation 6 Connect the thermal printer cable and the adapter to the ports on the rear panel of the InBody170 Install Manual 1 Raise the stand equipment as illustrated Hand Electrode Head Input Buttons if E 5 Hand Electrode Cable lt Rear view of InBody170 gt Stand o Foot Electrode 7 Connect the adapter to the power cord and plug it to the i i wall outlet s Base Contents of the Box InBody170 Joint Screw 1EA Joint Cover A Thermal Printer Screws 4EA Thermal Printer Paper Thermal Printer Cable Adapter 1EA 12V 3 4A Power Cord 1EA Install Manual 1EA User s Manual CD 1EA Warranty Cord Clips 2EA 3 Connect the thermal printer firmly to the supporting metal plate using the screws lt Side view of InBody 170 gt 8 If the air bubble is not in the center of the level indicator tighten or loosen the leveling screws 4EA on the foot plate to adjust the level lt Rear view of InBody170 gt of InBody170 InBody170 must
2. be leveled properly for accurate weight measurement 4 Open the thermal printer lid and insert the thermal printer paper in the direction illustrated Level Indicator a Leveling Screws lt InBody170 Base gt Please keep the packaging for future events of repacking InBody170 and sending Note for servicing or otherwise transporting InBody170 elsewhere 5 Thermal printer cables are connected as shown below Attach the cord 9 Turn the InBody170 and thermal printer on clips to the back of the InBody170 as illustrated below and fix the thermal printer cable into the clips 2 2 T boed wd If you use the InBody170 on a carpet static electricity may cause serious damage to the electronic components If the InBody170 is to be installed on a carpet use antistatic mats below the InBody170 Use InBody tissue to wipe feet and hands before the measurement starts N Do not wipe the base and hand electrode with cleaning liquids If cleaning liquids enter into InBody170 it may cause corrosion or electric shock by short circuit For cleaning of the InBody170 please use InBody tissue which also has antibacterial functionality r lt Rear view of InBody170 gt POWER Switch POWER Button wo Do not place the InBody170 directly against a wall The cables connected to InBody170 may get bent resulting in communic
3. heart lung Portable electronic medical devices such as an electrocardiograph Measurements may not be possible due to callouses on the palm or sole In this case wipe the palm and sole with an InBody Tissue before measuring oO oS Ue FAQs Q1 I do not know how to configure the settings A Press the button and then press the gg button The setup manual will be printed by the thermal printer Refer to the manual for descriptions of setup menu items and setup instructions Q2 pressed the button in order to change the setup configuration but InBody170 is asking for the access code What is the access code A The factory default access code is 0000 and it may be changed in the Setup menu Q3 How do adjust the sound volume A Press the Ee button on the home screen to adjust the sound volume To mute the voice guide press the Gg button The icon at the bottom of the home screen will disappear Q4 would like to set ID every time use InBody Is there an easy way to do this A Press the 4 button gt Enter the access code default is O000 gt Press the button twice gt Press the 1 button gt Press the gi button and then the button to bring up the home screen Q5 How do change Date Time A Press the 4 button gt Enter the access code default is O000 gt Press the i button Press the button until you see EEN a Date time are displayed at the bottom of the screen and they
4. asurement will begin When the measurement is complete the results screen will be displayed as illustrated below Gender Age Height e 30 cnn 38 605 Under Nomal Over Weight iil S80 MEISE ce l H m Ld Body Fat IIIT 3 Visceral Fat H 0 6 WEB 09 18 od InBody 5 Once the measurement is complete step off the foot plate The thermal printer will automatically print the results sheet about 15 seconds later i 1700H2_B indd 2 Proper Posture Proper posture is essential to achieve reliable results and high reproducibility Do not talk or move during the InBody test Armpits are not closed up Straight both arms If the examinee s thighs are in contact with each other have the examinee wear a pair of knee length shorts so that the thighs are not in contact each other Gently grip the hand electrodes so that all the four fingers of each hand are touching the surface of the either hand electrode Touch the circular electrode with the thumb Step on the foot plate with bare feet ensuring that both heels are touching the smaller foot electrode on either side as illustrated Do not wear socks during measurement Cautions before Measurement Do not use this equipment in combination with the following electronic medical devices Medical devices such as a pacemaker Electronic life support systems such as an artificial
5. ation faults or damage to the ports on the rear panel The measurement results may also be inaccurate if the base touches the nearest wall 4 Do not dismantle the equipment Internal parts are not for customer use and may cause electric shock If the equipment is dismantled the warranty is void and service costs will be charged Do not touch the base when turning on and during warm up Applying pressure or weight to the base during warm up will result in an inaccurate CAUTION calibration which may cause the measurements to be inaccurate lt Rear view of InBody170 gt 1700h2_B indd 1 S 2011 10 21 all 7 Measurement 1 Step on the foot plate and stand still until the weight is set Gender Age Height Gender Age Height Under Nomal Over Under Nomal Over Weight Weight Muscle Muscle Body Fat Body Fat Visceral Fat Visceral Fat 0 6 V08 09 18 0 InBody D D 08 09 8 w InBody 2 After weight is measured select gender with EY buttons Gender Age Height a A To enter your ID please press 8 button NOTE 3 Use input buttons to enter age and height in order Then press the button after entering each information to proceed Gender Age Height Gender Age Height 38 Gender Age Height oe 38 600 A Please enter your gender age and height accurately NOTE 4 Maintain correct posture and the me
6. can be changed by using the number buttons Q6 The thermal printer is not printing results sheet gee A Ensure that the thermal printer is turned on Also check that the paper is loaded in the thermal printer and the thermal printer cable is correctly connected Q7 Where can buy thermal printer paper and other optional devices A Please contact Biospace or the local distributor Q8 How do know if the correct measurement has been taken A After taking the measurement check the von aay een impedance at the bottom of the results sheet tat Arm 353 0s Under printed The impedance value must decrease Moia ao 1S em in the arrow direction Muscle Fat Controi T2Points Body Composition History Date Weight Musde Fat 10 12 09 447 199 78 10 12 09 447 186 98 20 489 8 488 0 30 1 270 2 266 6 aca E 450 2 26 3 244 2 242 0 ae zo 48 sho i Bho 2b 100 446 4 450 2 26 3 244 2 242 0 Impedance RA LA TR RL LL Q9 How do I clean the hand foot electrodes A Please use InBody tissues provided by Biospace and wipe the hand foot electrodes InBody tissues have antibacterial functionality which protects cross contamination BIOSPACE For any problems with InBody170 or for any clinical information contact Biospace Co Ltd Head office 518 10 Dogok 2 dong Gangnam gu Seoul 135 854 KOREA TEL 82 2 501 3939 FAX 82 2 501 3978 Homepage http www e inbody com E mail info biospace co kr For more
7. information on the functions of InBody170 and descriptions on the thermal results sheet items see the user s manual CD included For purpose of improvement specifications and design are subject to change without notice 1996 Biospace Co Ltd All rights reserved BM ENG C0 B 111017 F 2011 10 21 Qa 11 5000