Home
User Manual - S600 Standalone
Contents
1. Activated smartcard x 1 2 5A power adapter x 1 Power cord x 1 Key x 1 Cable clip x 8 M5 x 12mm screw x 6 Patented and Worldwide Patents Pending Each package bundled with activated smartcard x 1 The card on the bottom right shows two information SMARTCARD lt 1 gt Card number lt 2 gt Handle ID number x 2 for two handles This bundled smartcard has been activated in advance and authorized to unlock these two handles in the package UM ISU S600 Q413V5 P 1 www austin hughes com lt 1 2 gt Overall Installation Diagram Rear Door Front Door S 600P Proximity S 600M MiFARE SmartCard handle Optional door sensor with cable 2pcs for front amp rear door 2m Power cable door section 2pcs for front amp rear door 2m Data input connector for handle activation data input configuration Joint connector of amp Y Power cable cabinet section 0000000 Universal Auto switching 2 5A power adapter amp 6 power cord UM ISU S600 Q413V5 P 2 www austin hughes com Part Hardware lt 1 3 gt S 600 Handle Installation Custom Mounting Cut out on Cabinet Door for Handle Installation A e Itis highly important to make a correct handle mounting cut out on cabinet door Please 100 follow the diagram on the below to make the cut out Unit mm Cabinet door gt gt gt gt gt esL 1 A A A A gt e e o sm wee id A A A
2. Supported OS Platform amp Language Supported OS platform amp language list MS Windows XP Professional with SP3 32bit English edition only MS Windows 7 Professional with SP1 32bit amp 64bit English edition only MS Windows 8 Professional 32bit amp 64bit English edition only User can select the following languages under Control Panel gt Region and Language in English Edition OS 1 Arabic Saudi Arabia 2 Chinese Traditional Hong Kong S A R 3 Dutch Netherlands 4 English Australia 5 English United Kingdom 6 English United States 7 French France 8 German Germany 9 German Switzerland 10 Italian Italy 11 Japanese Japan 12 Korean Korea 13 Norwegian Norway 14 Portuguese Portugal 15 Russian Russia 16 Spanish Spain 17 Turkish Turkey UM ISU S600 Q413V5 Date and time formats Short date Long date Short time Long time First day of week dd MM yyyy dd MMMM yyyy HH mm ss Monday What does the notation mean Examples Short date Long date Short time Long time 25 06 2013 25 June 2013 10 01 10 01 40 Go online to learn about changing languages and regional formats P 21 www austin hughes com lt 4 3 gt Utilities ISU 01 Download amp Installation After the handle installation please take the following steps to install the utilities 1 Prepare a notebook computer to download the handle setup u
3. gt Steps for 1 Click Export and Click Yes from the pop up window 2 Provide the name and path of the export file and follow the instruction to complete the export Infra Solution 5 Hites ISU 41 Handle Informatica Handie ID 2057 31273 8 P D1 Madel A NE l whe Pram asi pated UT H TE r Handle nenii HAT ie H Fieri Hack 1 Handi psi Livan fe Foul O Rcar Doc Sensor fa Dizab O Cral mM VOD Te ri GOT Seve 4710 iFa Pal awd carnin Uehara ka Teo KOT ede Arrr ranere se f al rara a Mon mnl erman bhale CJ Biama ser coal aile 4 Be Gal Cand Qutertication dmm can ser can administrador card ne eH awe Aus Soicinmnereg Sala wl hamle CET al LH eC UM ISU S600 Q413V5 P 31 www austin hughes com lt 5 3 gt Export amp Import Handle Configuration Steps for 1 Select the handle which you want to import handle configuration file 2 Connect the handle to the notebook computer via the handle data input cable ISW USB 1 8 3 Click Import and Click Yes from the pop up window 4 Select the file to import amp follow the instruction to complete the import step 5 After import completed edit the field s on Zone Rack if necessary 6 Click Apply to finish file import Infra Sal ution We ISU Hindle Informatica Handke ID 2451 51279 6P D001 Mudel H0r ype P
4. door ISK C051 e Up to 500 individual key locks available Unique key lock ISK UKL e Unique key dedicated to single project customer regionally e For project size over 500 cabinets Dual card authentication DCS 01 e Software upgrade for additional security e Cabinet access by administrator card user card Order this option before the delivery Proximity smartcard pack of 10 ISC P10 e Proximity 26 bit format e Single card for multiple application e Custom card layout available MiFARE smartcard pack of 10 ISC M10 e MIFARE 26 bit format e Single card for multiple application e Custom card layout available Proximity card reader ISC PCR e Proximity 26 bit smartcard compatible e Convenient way for smartcard ID reading e Driverless for easy installation MiFARE card reader ISC MCR e MIFARE 26 bit smartcard compatible e Convenient way for smartcard ID reading e Driverless for easy installation The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2013 Austin Hughes Electronics Ltd All rights reserved UM ISU S600 Q413V5 POO www austin hughes com
5. hughes com lt 2 1 gt Two Important Notes Lock Unlock the handle by mechanical key A e Unless the smartcard handle is defective lock unlock the handle by key is NOT recommended e Please insert amp turn the key with Key lock mode Key cylinder to 9 o clock direction Key unlock mode Key cylinder to 3 o clock direction Maintenance Key MK 001 e Improper key usage may cause the cylinder stuck at abnormal direction 1 to 2 o clock e Under this circumstance the maintenance key MK 001 is required to solve the problem e Please insert the maintenance key to the cylinder with push force for turning it to normal direction 9 or 12 or 3 o clock At LoS a JGHIN i UM ISU S600 Q413V5 P 14 www austin hughes com Part Il Handle Usage amp Operation lt 2 2 gt Handle Operation with Door Sensor V How to unlock the handle amp open the door properly Unlocked status in silver white v Locked status in blue or green v o Flashing Flashing gt gt gt Stop gt To open the door within 10 seconds x Unlock the handle but NOT open the door Locked status in Unlocked status in blue or green silver white WwW wW f Flashing over 10 seconds x Unauthorized door open Locked status in Unlocked status in blue or green red v v NO Authenticated Smartcard Detection Flashing Door Opening improperly or by force UM ISU S600 Q413V
6. mm sm 128 148 UM ISU S600 Q413V5 P 3 www austin hughes com lt 1 3 gt S 600 Handle Installation Side View Side View Close Open 213 Unit mm A S 600 handle design supports left side amp right side open UM ISU S600 Q413V5 P 4 www austin hughes com Part Hardware lt 1 3 gt S 600 Handle Installation Handle Installation Steps 1 Mount S 600 handle to the custom handle mounting cut out position 2 Insert the bundled M5 x 12mm screw x 3 pcs to secure the handle in place ed a M5 x 12mm screw e While insert the screws to secure the handle with electronic screwdriver please set the torque NOT exceed 8 kgf cm UM ISU S600 Q413V5 RO www austin hughes com lt 1 3 gt S 600 Handle Installation Parts of Cabinet Door Locking Bar Three parts available for cabinet manufacturer to produce the cabinet door locking bar system integrated with S 600 handle Locking bar handle bracket pc Order part no 404 8 02111 material alloy fixing screw not provided Dimension Diagram on next page Locking bar retaining bracket pc Order part no 314 0 10010 material alloy fixing screw not provided Dimension Diagram on next page Locking bar roller pc Order part no 314 0 10020 material alloy fixing screw not provided Dimension Diagram on next page UM ISU S600 Q413V5 P 6 lt lt lt lt lt Locking
7. the LED light change to RED after present a valid user card without open the door remind you the cabinet security at risk now because the handle in unlock status but the door not open yet 4 Why can t open the door even I presented a valid user card to the handle ensure the handle lock under the smartcard mode that key cylinder at 12 o clock direction Please refer user manual Part II lt 2 1 gt Two Important Notes 1 Where can I get the USB driver for the data input cable ISW USB 1 8 for 32 bit OS http www austin hughes com support utilities infrasolutionS ISW USBV20828 32bit 7z for 64 bit OS http www austin hughes com support utilities infrasolutionS ISW USBV20828 64bit 7z 2 Where can find the Catalog User manual Model list of Cabinet Smart Card Handle please visit www austin hughes com 3 How can get further support please send email to support austin hughes com or sales austin hughes com UM ISU S600 Q413V5 P 33 www austin hughes com Part Vil Troubleshooting 1 Handle ID no not shown in UI Step 1 Handle is OFF ensure the handle is in power ON status Step 2 Check the driver of the data input cable installed properly ensure the driver is installed properly Please refer to user manual Part IV lt 4 4 gt Driver installation for Data Input Cable Step 3 Check the USB port of the notebook computer Try to plug the data input cable into another USB port of
8. the cable with cable clips bundle with handle package d _ r place the sensor at the top of the door close to the opening side adjust the sensor with adhesive tape to ensure the sensing distance between door to frame within 3mm while door in close status nl LL Sensor Operation DOOR CLOSE DOOR OPEN close door open door inductive sensor detects the cabinet frame DOOR CLOSE SIGNAL sends out Cabinet frame Door frame CLOSED Il Il 11 Oo Sensing distance lt 3mm UM ISU S600 Q413V5 inductive sensor lose detection with cabinet frame Red LED of sensor light up DOOR OPEN SIGNAL sends out Cabinet frame OPENED Sensing distance gt 3mm P 10 www austin hughes com Part Hardware lt 1 4 gt Door Sensor Installation Mechanical Sensor Mechanical Door Sensor S DSW Features e low cost precise e cost efficient integration to new cabinet unit mm Front View Top View Side View D 52 0 Steel mounting plate with 2 screw holes Cable connector Press button total travel distance 9 25 mm min actuation distance 3 00 mm Package content e Mechanical sensor w 2m cable x 2 Mounting screws 6 32x4 5mm x 2 unit mm Requirements e custom hole cutting required on doors 37 5 ordering a sample for custom cutting is highly suggested O 0 2 9 min actuation dis
9. the notebook computer Step 4 Data input cable defective Replace another data input cable 2 Handle can t be locked after closed the door Step 1 Check door sensor is installed If NO door sensor is installed please select disable in lt Door sensor gt in ISU 01 Otherwise the handle CANNOT be locked after you unlock it Step 2 Door sensor sensing distance when door close greater than 3mm Inductive sensor only Ensure the distance between the door sensor and cabinet frame is LESS than 3 mm Please refer to user manual Part lt 1 4 gt Door Sensor Installation Step 3 Handle lock under key unlock mode and key cylinder at 3 o clock direction Ensure the handle lock under the smartcard mode that key cylinder at 12 o clock Please refer to user manual Part II lt 2 1 gt Two Important Notes UM ISU S600 Q413V5 P 34 www austin hughes com Part VIII Optional Acccessories Inductive door sensor pair S DSI e Light weight mini size amp adhesive e No custom cutting required on doors e Easy for existing cabinet retrofit or integration to new cabinet Mechanical door sensor pair S DSW e Low cost e Precise e Cost efficient integration to new cabinet e Custom cutting required on doors Handle data input cable pc ISW USB 1 8 e Connect the smartcard handle to the laptop for handle activation data input amp configuration Individual key lock set of two for front amp rear
10. 5 P 15 A Within 10 seconds after smartcard detection users should lift up the handle open the door return the handle to park position properly in case reckless collision causes handle damage Over 10 seconds the handle still keeps unlock Unlocked status in If DO NOT lift up the handle and open the door within 10 seconds the LED will change to RED to draw user s attention that the handle in unlock status and cabinet security at risk now If the door is opened improp erly or by force handle LED will turn to red flashing with audio alarm beep sound www austin hughes com lt 2 2 gt Handle Operation with Door Sensor Vv How to close the door properly Unlocked status in Locked status in silver white blue or green Ww v Users should lift up the handle gt close the door gt return the handle to park position properly To close the door within 10 seconds Over 10 seconds the handle will auto lock UM ISU S600 Q413V5 P16 www austin hughes com Part Il Handle Usage amp Operation lt 2 3 gt Handle Operation without Door Sensor Vv How to unlock the handle amp open the door properly Locked status in Unlocked status in blue or green silver white wW Ww At gt p gt To open the door LAY ya ci oN e yor eee Flashing Flashing OR Stop within 10 seconds x Unlock the handle but NOT
11. Bar www austin hughes com Part Hardware lt 1 3 gt S 600 Handle Installation Locking bar handle bracket pc Order part no 404 8 02111 material alloy fixing screw not provided UM ISU S600 Q413V5 P 7 www austin hughes com lt 1 3 gt S 600 Handle Installation Locking bar retaining bracket pc Order part no 314 0 10010 material alloy fixing screw not provided Locking bar roller pc Order part no 314 0 10020 material alloy fixing screw not provided UM ISU S600 Q413V5 P 8 www austin hughes com Part Hardware lt 1 4 gt Door Sensor Installation Inductive Sensor Optional door sensor is an essential accessories as users can be alerted by visual and audio alarm for unauthorized access Inductive Door Sensor pair S DSI Features e light weight adhesive mini size 32 5 x 12 2 x 9 2 mm e no custom cutting required on door Front View 12 2 mm 1 n pem Red LED light up while door opening Cable jack connect to handle j es 2mm adhesive tape Package content e Inductive sensor w 2m cable x 2 e 2mm adhesive tape x 6 Requirements e cabinet frame made of ferrous metal iron sensing distance 3mm UM ISU S600 Q413V5 P 9 www austin hughes com lt 1 4 gt Door Sensor Installation Inductive Sensor Suggested Installation steps sensor position connect to the handle l guide amp fix
12. InfraSolution S SmartCard Access Control for Cabinets User Manual Utilities ISU 01 S 600 Standalone Cabinet SmartCard Handle B Designed and manufactured by Austin Hughes FE ce REACH UM ISU S600 Q413V5 www austin hughes com Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference m Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth H Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit E When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing damage to other equipment or injury to persons nearby m When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating m Arrange the equipments power cord in such a way that others won t trip or fall over it MH If y
13. User MUST order Dual card authentication option before delivery Administrator card mo 10802502 While unlock the handle and open the door under Dual card authentication mode present the admin card first then user card within 10 seconds UM ISU S600 Q413V5 P 29 www austin hughes com lt 5 2 gt Card Assignment In lt Card Assignment gt assign edit or delete user card Card Aselgnimienl Max 30 L ES RE 10126156 z al EE i KL a DURS fm Wi ho Card Assignment by two methods 1 Click Card Edit then direct input the last 8 digits of the card number to the field 2 Click Card Edit then present the smartcard to the handle and the last 8 digits of the card number will be input to the field simultaneously amp automatically Card no Change 1 Click Card Edit then change the existing card numbers in the field Card Delete 1 Click Card Edit then delete the card number in the field one by one All Card Delete 1 Click Delete then confirm this command and all card assignment will be deleted A Click Apply to finish the above configuration for smartcard UM ISU S600 Q413V5 P30 www austin hughes com Part V Software Usage lt 5 3 gt Export amp Import Handle Configuration In lt Export gt and lt Import gt provide a quick way to configure other handles with same or similar configuration on lt Card Assignment gt lt Door Sensor gt lt Card Access Mode
14. hardware amp software installation please take the following steps to configure the handle 1 Prepare the notebook computer installed with utilities ISU 01 2 Connect to the handle via the handle data input cable ISW USB 1 8 3 Make sure the handle in power ON status 4 Configure the handle according to the UI 5 After finish the handle configuration please repeat the steps for other handles One by One Handle Data Input Cable ISW USB 1 8 BE C iin To To USB port handle data connector A If the OS platform of the notebook computer is MS Windows 7 please take the following steps Right Click InfraSolution S Utilities ISU 01 and then Select Properties Click the Compatibility tab Tick the box Run this program as an administrator and then Click OK If don t take the above steps the UI will not display properly UM ISU S600 Q413V5 P 27 www austin hughes com lt 5 1 gt Initial Handle Configuration Infra Solution amp Utilities 1SU O4 Lait CE HU Card Aagdnmeanr Arns vl Hamile Infam Handke ID 2457 3127 3 GP0001 Mudel ris Sr l en Pres Las pdd A Dy TIE bee landle Location Handia pexalrin Boor Sensor El Cisab LJ Crete neus you nas orders COST Ragone atd eed ha betelalcn awd carnsction harskes TaD UT anshi ni eee ae i ai capes res Ann Clonal Mes ram bhale be Biama ser cal mile Y O Ma Card artarkan i Set Isa CAM l
15. ht click My computer amp Select Manage Click Device Manager Then user can see an improper USB UART driver installed under Other devices E server Manager Fie Action Mew Help bol Ae eel Ie ss More chons E Event Viewer E 8 Performance dy Device Manager E gy Configuration El CP Task Scheduler E ir Windows Firewed with Adre M Display adapters A DVDACO ROM drives e Flopoy drive controllers A Human Interface Devices ijg IDE ATA ATAPI controllers Keyboard Mice and other pointing devices E Monitors os Network adapters fp Other devices FT24 USE UART 1 Ports COM amp LPT Communications Part COM TE Communications Port CoM T Printer Port LPT1 H Processors HE System devices Ho Universel Serial Bus contrafers Le S wces g WMI Control El a Local Users and Groups Dude bel bel Bel ee lti it Lel iH itl Le fs ela UM ISU S600 Q413V5 P 23 www austin hughes com lt 4 4 gt Driver Installation for Data Input Cable Step 3 Right Click the improper installed USB UART driver amp Select Update Driver Software El lp ils devina i SEES eR Lt peche OC Intake Diricer Saver 7 Parts OK fl F i US Lemmnrat YS tennant rll ES Sinter Port e il Sem dure fl Lkiversel Serial H Step 4 A window pops up amp please Select Browse my computer for dri
16. iser cad i D H US Handle Information In lt Handle Information gt shows the handle ID model card type amp the time of last configuration llandle Information ANT 2 TS LUF Tandle IU Model 2 00 roca rcaky lype Last updated 20144 U4 18 547 UM ISU S600 Q413V5 P 28 www austin hughes com Part V Software Usage lt 5 1 gt Initial Handle Configuration Handle Location In lt Handle Location gt record the Zone Rack and Handle position of the handle llandle Loc ation fone Zon c E Hack Rac k_B llandle position ront C Rear Door Sensor Option In lt Door Sensor gt enable or disable the door sensor Default is Disable A Ensure you have ordered door sensors and finished the installation Otherwise DO NOT enable door sensor as it will cause malfunction Door Sermnsor kA Os ble L _nebl Eraur yo howe Incr doar Scraora ard hn herve CC HOT enable dwn serso as Card Access Mode Option In lt Card Access Mode gt select the handle to run as Normal OR Dual Card Authentication mode A If select Dual Card Authentication please input Administrator card no Card Access Mode LI Mormeal User card acte M Dual Card Authentication Acmuicistratcr card User cars Only ONE admin card for each handle
17. le will auto lock UM ISU S600 Q413V5 P16 www austin hughes com Part Ill Hardware Specifications 100 240VAC 50 60Hz 0 5A via AC DC cord Regulation Approval FCC CE 0 to 50 C Degree 5 to 60 C Degree Environmental Relative Humidity 90 non condensing 50G peak acceleration 11 ms half sine wave 58 100Hz 0 98G 11ms cycle Gross Weight 1 82 kg 4 0 lbs Packing 310 x 310 x 95 mm Carton size WxLxH 12 2 x 12 2 x 3 7 inch Safety Regulatory FCC amp CE certified Environmental RoHS2 amp REACH compliant UM ISU S600 Q413V5 P 19 www austin hughes com Part IV Software Download lt 4 1 gt Software Features amp Hardware Requirements Software Features Utilities Max 500 pairs of handle Max 50 user card authentication per handle Dual or single card mode authentication Enable or disable door sensor detection Detailed user card information Reporting on configuration details Log in password Optional feature Hardware Requirements Please prepare a notebook computer with the hardware specifications as below for InfraSolution S Utilities ISU 01 Recommended hardware Processor Dual Core 2GHz or above Memory 2GB RAM Available Disk Space 2GB Display 1024 x 768 or higher resolution A USB port x 1 required for the data input cable amp smartcard handle configuration UM ISU S600 Q413V5 P 20 www austin hughes com Part IV Software Download lt 4 2 gt
18. open the door Unlocked status in silver white Locked status in blue or green vw vw o Flashing over 10 seconds x Unauthorized door open Locked status in Unlocked status blue or green in blue or green vw vw Door Opening improperly or by force NO Authenticated Smartcard Detection gt UM ISU S600 Q413V5 PAT Locked status in blue or green v amp Within 10 seconds after smartcard detection users should lift up the handle open the door return the handle to park position properly in case reckless collision causes handle damage Over 10 seconds the handle will auto lock Locked status in blue or green a If DO NOT lift up the handle and open the door within 10 seconds the LED will change to BLUE or GREEN and the handle returns locked If the door is opened improperly or by force handle LED remains in BLUE or GREEN but no any audio alarm beep sounds for warning www austin hughes com lt 2 3 gt Handle Operation without Door Sensor Vv How to close the door properly Locked status in Unlocked status in Locked status in blue or green silver white blue or green vw D 4 v SES A A ss s55 Flashing rire Within 10 seconds after smartcard detection users should lift up the handle At 5 close the door return the handle to park lass Over 10 seconds the within 10 seconds hand
19. ou are using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipment s ratings label mM Observe all precautions and warnings attached to the equipment MH If you don t intend on using the equipment for a long time disconnect it from the power outlet to prevent being damaged by transient over voltage H Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock H Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invalidate its warranty MH If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover MH Any product on which the serial number has been defaced modified or removed E Damage deterioration or malfunction resulting from O Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product CT Repair or attempted repair by anyone not authorized by us L Any damage of the product due to shipment O Removal or installation of the product O Causes external to the product such a
20. resni Las n pian AD Das IE Ua Handle atone TA ia H Fiver Hark l Ail prala f Feul O Rar Doct Sensor fa Dizab O Crcble Ce yo ee de o RS ee a10 ked Fa meilin aid carmin Uehara ka To HOT ees Arrr anero ae Pow rar res Anden mnl Mes am bhale Q Fionna ser cal mily k Gaal Cand aatkalkn i dnra nam ser cad Sdminl tradoer card mo TRE MERIT sus cine gala eli haml a Ll a el Le SS ets UM ISU S600 Q413V5 P 32 www austin hughes com Part VI FAQ 1 What is Utilities ISU 01 ISU 01 is a Windows based utility to provide a simple amp user friendly way for initial handle setup 2 Which OS platform does ISU 01 support MS Windows XP Professional with SP3 32bit MS Windows 7 Professional with SP1 3 Why the handle ID no NOT show in UI ensure the handle is in power ON status ensure the driver installation for data input cable ISW USB 1 8 completed 4 How to do if lost the user card open the door by key and edit the card assignment 5 Why can t select Dual card authentication in ISU 01 ensure you have ordered this option before delivery if this option required after handle installation you need to order a new handle with this option amp replace the existing one Smartcard Handle 1 How many user card can assign to each handle up to 50 2 How many Administrator card can assign to each handle one 3 Why does
21. s electric power fluctuation or failure O Use of supplies or parts not meeting our specifications O Normal wear and tear L Any other causes which does not relate to a product defect E Removal installation and set up service charges Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures M Re position or relocate the receiving antenna H Increase the separation between the equipment and receiver E Connect the equipment into an outlet on a circuit different from that to which the receiver is connected UM ISU S600 Q413V5 www austin hughes com Part I l
22. t 1 1 gt lt 1 2 gt lt 1 3 gt lt 1 4 gt Part Il lt 2 1 gt lt 2 2 gt lt 2 3 gt Part Ill Content Hardware Package Contents Overall Installation Diagram S 600 Handle Installation Door Sensor Installation Inductive Sensor Mechanical Sensor Handle Usage amp Operation Two Important Notes Handle Operation with Door Sensor Handle Operation without Door Sensor Hardware Specifications Part IV Software Download lt 4 1 gt lt 4 2 gt lt 4 2 gt lt 4 3 gt Part V lt 5 1 gt lt 5 2 gt lt 5 3 gt Software Features amp Hardware Requirements Supported OS Platform amp Language Utilities ISU 01 Download amp Installation Driver Installation for Data Input Cable Software Usage Initial Handle Configuration Card Assignment Export amp Import Handle Configuration Part VI FAQ Part VII Troubleshooting Part VIII Optional Acccessories UM ISU S600 Q413V5 P 1 P2 Po P 9 P 13 P 15 P 17 P 19 P 20 P 21 P 22 P 23 P 27 P 30 P 31 P 33 P 34 P 35 www austin hughes com Part Hardware lt 1 1 gt Package Contents Unpacking The equipment comes with the standard parts shown on the package contents Check and make sure they are included and in good condition If anything is missing or damage contact the supplier immediately S 600 Package Content 600 smart card handle pair MIFARE Proximity Y Power cable x 1
23. t Controller 2374 tet CHE Pedy USI Unnversal Most Controller T371 rte ICS Pedy USI Universal Host Controber T97 D rte LOS Faniy LISE Ltwersai Host Controder 2957 bef ICS Pam y USI Universal Host Controller 2929 Def H rady USD Universal Host Controber 2975 E rte DCS raniy S02 Erhenced host Controler 297 inte ICE Pandy UZ Enhanced Host Controber 2930 LES Composite Deis D USE Boot Hub USE ont Hub USE Ent Hub M USE Root Hub USE Evot Hub USE Roat Hub UGE Pert Hub USE Rest Hub UM ISU S600 Q413V5 P 25 www austin hughes com lt 4 4 gt Driver Installation for Data Input Cable Step 10 Right Click USB Serial Port under Other devices amp Select Update Driver Software Date Thr LOT 2 diabe mnst l a T we TUTE er Srinter M DE e e e bee changes of Pe Ce lll Sem 4 si Step 11 Select Browse my computer for driver software Genuse my computer tor dorer sous Locabe snc metal driver coftware manual w 4 Step 12 Click Browse to search the correct path of the driver software amp Click Next to install the driver Browse for driver software on your computer 4 F Include subfolders Step 13 It takes a few seconds to complete When complete Click Close e Complete P 26 www austin hughes com UM ISU S600 Q413V5 Part V Software Usage lt 5 1 gt Initial Handle Configuration After
24. tance 3 00 mm O total travel distance 9 25 mm Dimension of door cutting hole circle hole x 2 for screw mounting rectangle hole x 1 for sensor installation UM ISU S600 Q413V5 P 11 www austin hughes com lt 1 4 gt Door Sensor Installation Mechanical Sensor Installation steps Suggested connect to the handle w sensor position place the sensor at the top middle of the door install the sensor in the custom hole secure it with bundled mounting screws 6 32x4 5mm x 2 Sensor Operation DOOR CLOSE DOOR OPEN close door open door Sensor button is pressed on Sensor button is released DOOR CLOSE SIGNAL sends out DOOR OPEN SIGNAL sends out Cabinet frame Door Cabinet frame frame OPENED Button released Actuation distance gt 3mm Physical touch required UM ISU S600 Q413V5 P 12 www austin hughes com Part Il Handle Usage amp Operation lt 2 1 gt Two Important Notes Handle Sensor Area amp SmartCard Mode Sensor area Present the smartcard and touch the handle sensor area for 1 to 2 seconds manne For smartcard operation keep key cylinder always to 12 o clock direction Key lock mode Key cylinder to 9 o clock direction Under key lock mode even present the smartcard the handle still keeps locked Key unlock mode Key cylinder to 3 o clock direction Under key unlock mode the handle keeps unlocked UM ISU S600 Q413V5 P 13 www austin
25. tilities from the link http www austin hughes com support utilities infrasolutionS ISU 01 msi 2 Double click the ISU 01 msi and follow the instruction to complete the installation ISU 01 msi Welcome to the InfraSolution S Utilities ISU O1 Setup Wizard The Selop Wau wil ie La fof Sculivn 5 Dies 151 01 on Your computer Click ext to continue or Tanca to Ext tre Setuc Wizard click Next click Install click Finish Completing the InfraSolution S Utilities ISU 01 Setup Wizard Shes Je Fire bobo Le exil the Se Winer ol e e e Complete UM ISU S600 Q413V5 P 22 www austin hughes com Part IV Software Download lt 4 4 gt Driver Installation for Data Input Cable Before initial configuration for handles user MUST install the driver for the data input cable ONCE Please follow 13 steps below to complete the installation Step 1 Connect the handle to the notebook computer via the handle data input cable ISW USB 1 8 A Make sure the handle in power ON status Handle Data Input Cable ISW USB 1 8 BEM NL a To To USB port handle data connector A If the notebook is MAC model users may need to download the USB driver to run Windows OS under MAC notebook PC http www austin hughes com support utilities infrasolutionS ISW USBV20828 32bit 7z OR http www austin hughes com support utilities infrasolutionS ISW USBV20828 64bit 7z Step 2 Rig
26. ver software Browse my computer for driver software Lace and instal deve share Taney Step 5 Click Browse to search the path of the driver software Search fre derari sail bw ma her ler atl oe UM ISU S600 Q413V5 P 24 www austin hughes com Part IV Software Download lt 4 4 gt Driver Installation for Data Input Cable Step 6 Select C gt Program Files gt _InfraSolution S Setup Utilities gt Driver amp Click OK Step 7 Browse For Folder Select the folder that contains drivers for your hardware InfraPower Manager IPM 02 Bu InfraSolution 5 Setup Utilities Click Next to install the driver Step 8 It takes a few seconds to complete When complete Click Close Step 9 USB Serial Converter shows under Universal Serial Bus controllers E tmur Hanagar Be Acton Len Hep F M Erari etre F a Fetan d Sevi A WHL Convo 3 MP Lo cal Users bd Groups D deers 270 l MS _ D Fi Si Boles a Ooo dress f 2 Mi Dap adape i DVCHCELALOM driven ie Sopa dra cori okem En Honan Enterface Derrian IDE ATA STAPI con bollere gt phoan rt P Fia ard other poinbmg derama a i pontom 4 Metardk ademters EI Conmuncstons Port COM Li F Communicators Port COM FP Porter Port PTL Proper PIE Sten devices Unteernel Serial tus controles rte ICS Pay UST UnwersalHos
Download Pdf Manuals
Related Search
Related Contents
EZ Sand - Floor Style Products Übungen zur Ökologie SS2006 Kursteil Pflanzenökologie II 39 - BERLINER WOCHE Samsung Digimax S800 User's Manual User`s Manual (EN) Owner`s/Operator`s Manual Manuel de l`utilisateur/opérateur Bedienungsanleitung SCXー200-2 product user guide GEEEHIIB Copyright © All rights reserved.