Home

MASTER CALI Avanti MANUAL 30,12,11

image

Contents

1. Fig 5 Chrono mode Icon Dot indicating day of week 7 Day week reference Time setting bar PROGRAMMER FUNCTIONS SETTINGS SEVEN DAY PROGRAMMING SETTING A WEEKLY SCHEDULE After setting the time and day go on to weekly programming Set a sequence for each hour and each day of the week Use the and buttons to make selections The button indicates high temperature regulation for that time and the button indicates low temperature regulation The segments on the time setting bar correspond to high temperature and the empty space corresponds to low temperature see fig 6 Press the function button to save the day s settings then start the same procedure for the next day When each day s timings and temperatures have been set for a complete seven day cycle ensure the function button is pressed after making each setting to save it the screen will show the time program and the chrono symbol Fig 6 J 2 4 6 8 IW Ic 14 16 18 cU ce OPERATING MANUALLY NO PROGRAMMING Firstly select the Comfort mode by pressing the Function button until the Sun symbol appears see fig 7 Fig 7 Comfort Mode Icon o l The thermostat radiator can then be Thermometer symbol I 51 70 4 set to reach maintain your required ELUT g ambient temperature by pressing the plus and minus buttons to raise 9 8 12 16 20 24 or lower the temperature setting
2. MAINTENANCE At regular periods check the condition of the programmer and make sure the buttons and the display work properly Push the buttons to select the modes as described on pages 7 8 and 9 CLEANING Use only a clean soft dry cloth to clean the programmer Hold the programmer steady with one hand whilst cleaning it using your other hand by making small round movements with the cloth do not apply pressure DIAGNOSTICS If the programmer seems to work correctly but the radiator is not heating at all this may indicate possible cutting in of the protection devices in the heating element If the display shows ErrS the temperature sensor is damaged or the temperature is outside operating limits SPARE PARTS In the event of the programmer unit malfunctioning or becoming damaged this entire unit must be replaced no spare components available by an original programmer unit supplied by the manufacturer Any such work must be carried out by an electrician approved by the manufacturer or by a suitably qualified experienced electrician familiar with such products who has the necessary instructions APPLICABLE EUROPEAN STANDARDS Electrical tests according to CEI EN 60335 1 2002 A1 2004 EN 60335 2 30 2003 CEI EN 55014 1 2000 A1 2001 A2 2002 EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 EN 55014 2 1997 A1 2001 EN 50366 2003 Applicable directives RoHS Directive 2006 95 CE Low Voltage Directive and 2004 108 CE Directive EMC
3. Company Trading name Telephone numbers Email address Contact name PROVISION FOR USER NOTES amp IntelliHcat Intelligent Heating Solutions INTELLI HEAT Ltd Company Registration Number 05950029 Unit 18 Napier Place Stephenson Way Thetford Norfolk IP24 3RL www intelligentheat co uk E tech intelligentheat co uk www intelligentheat co uk support ISSUE REFERENCE CAV MANUAL 01 3 1 12
4. 0950 1200 580 770 90 19 CAV 1200 1500 580 930 90 24 CAV 1500 1800 580 1090 90 29 CAV 1800 The crossed out wheeled bin symbol reminds you that in the European Union all electrical and electronic products and batteries must be taken to separate collection points at the end of their CL il E i P24 working life Do not dispose of this product as unsorted municipal waste Take this product to a collection point that prevents possible harm to the environment or human health from l uncontrolled waste disposal and to promote the sustainable reuse of material resources EE Collection information is available from waste authorities or national producer organizations A ALWAYS HANDLE HEAVY ITEMS WITH CARE Please take every safety precaution when lifting moving and installing this product We strongly advise that you are assisted when installing this product 5 ELECTRICAL INSTALLATION GUIDELINES IMPORTANT THIS PRODUCT IS DOUBLE INSULATED Therefore connection to Earth is prohibited The cable contains the following colour coded wires BROWN LIVE LINE GREY or BLUE NEUTRAL BLACK PILOT WIRE The black wire is a signal wire only to be used for connection to an external pilot wire programmer do not connect it to any EARTH LIVE or NEUTRAL terminal this will destroy the thermostat If the black pilot wire is not connect to an external pilot wire programmer it must be properly insulated isolated The power cable to this appliance is not s
5. 9 WARRANTY PURCHASE DETAILS WARRANTY This product includes a free warranty covering five years for the body and two years for the electronics This warranty starts from your delivery date receipt of the product and covers any miss function that may arise due to the faulty manufacture of the product It does not cover any fault caused by miss use or damage caused by the purchaser or other persons or incorrect installation or non compliance with these instructions after delivery receipt This warranty exclusively covers the repair or replacement free of charge of parts the product or if necessary full product replacement recognized as being faulty INTELLI HEAT Ltd cannot be held responsible to undertake disassembly and assembly works or to refund any expenses incurred for such works or for any direct or indirect damage to persons or property due to any miss functioning of the product Please ensure that you keep all documentation and invoice relating to this product as this will be required should you need to use this warranty Thank vou for choosing an INTELLI HEAT product and we wish you a lasting and enjoyable use of this product 3 IntelliHcat Intelligent Heating Solutions PLEASE ENSURE THAT YOU KEEPA RECORD OF THESE DETAILS Date of purchase Date goods received Model s purchased SUPPLIER DETAILS Company Supplier name Telephone numbers Email address Contact name INSTALLER DETAILS Date of installation
6. INSTALLATION GUIDE AND USER MANUAL The CALI Avanti Thermodynamic fluid filled electric radiator With integral 7 Day LCD Programmer 2 IntelliHcat Intelligent Heating Solutions 1 Please ensure that these instructions and guidelines are fully understood and adhered to when installing and using this appliance TABLE OF CONTENTS With Intelligent Thermostat amp Seven Day LCD Programmer amp IntelliHcat Intelligent Heating Solutions PLEASE PAY SPECIAL ATTENTION Do not touch any part of the radiator when you are wet Do not install outdoors This product is safe and water resistant Nevertheless do not touch the radiator or the thermostat when any part of you is wet This product is for interior use only Cleaning Ensure turned off at the main power source and clean with a soft non abrasive damp cloth Never allow water to splash onto any part of the appliance Do not cover or lay any material or object over on the radiator Do not lay any material over the radiator especially if it is damp or wet Never place any object against the radiator Always ensure that the radiator is installed in an open area to allow the warmth to be radiated and not where curtains will be drawn over it Please take care when children are around Although this product is designed to ensure safety and ease of use like with any other electrical or heating product always exercise caution where children are concerned
7. We strongly advise you not to allow children or any unsuitable person to operate the controls or to tamper with any electrical connection Never hang from the radiator or load it with weight Never pull sit on hang from or load the radiator with any weight Such practice may damage the radiator or cause it to come loose from the wall or the wall fitting attachments which could cause serious injury Also to avoid such injury check from time to time to ensure that the radiator is securely fixed to the wall Do not tamper with or modify this product Never attempt to alter or modify this product paint it or apply stickers This will invalidate the warranty and may cause the product to malfunction or personal injury DO NOT Connect the BLACK WIRE to any EARTH LIVE or NEUTRAL terminal The black wire must only be used for connection to an external Pilot Wire Programmer Connection of the black wire to any other terminal will destroy the thermostat If the black wire is not used for connection to a Pilot Wire programmer it must be properly insulated and isolated This appliance is Double Insulated therefore it must not be Earthed The cable contains BROWN Live GREY BLUE Neutral BLACK the Signal Wire GENERAL GUIDELINES 1 INTELLI HEAT Ltd or any associated company or person cannot be held responsible for any fault damage or personal injury caused if these instructions have not been fully adhered to or where non original
8. al for the regulator setting to be different to achieve the same temperature in two separate places effect of the surrounding environment The Chrono mode uses the temperature levels as shown in fig 3 below Fig 3 CHILD ANTI TAMPER LOCK This option can be used to block lock the buttons so that they cannot be used which prevents inadvertent setting changes or tampering by unauthorized persons and children To lock hold down the and buttons simultaneously for at least 3 seconds The padlock icon will appear to confirm that control access is blocked Fig 4 t a Lock Icon e JU E To unlock controls again press the M and buttons simultaneously for pp at least 3 seconds the lock symbol 0 4 l2 16 20 24 will disappear allowing full access SEVEN DAY PROGRAMMING SETTING THE TIME AND DAY Firstly select the Chrono mode by pressing the Function button Each time the function button is pressed the function mode will change indicated by the mode symbol at the top left side of the screen When the Chrono mode has been selected set clock symbol hold down the ON standby and function buttons simultaneously for at least 3 seconds The hour digits begin to flash Use and buttons to set the current hour and confirm by pressing the function button Set the minutes and day in the same way The day is marked by a dot on the vertical numbered scale see fig 5 below
9. ature 2 C Night temperature reduction mode or can also be used as a background temperature setting Enables unlimited time regulation to maintain a comfortable temperature with minimum energy consumption All Pilot wire commands except STOP are disabled REDUCTION NIGHT MODE The ambient comfort temperature will correspond with the temperature set by the user COMFORT Unlimited time regulation to the high temperature All Pilot wire commands except STOP are disabled ag TE ag FROST Unlimited time regulation fixed at 7 C for protection against freezing frost damage The heater comes on automatically when the ambient temperature drops lower than 7 PROTECTION P p C All Pilot wire commands except STOP are disabled PROGRAMMER FUNCTIONS SETTINGS Temperature settings are at two different levels 1 High temperature is used by the Chrono Pilot wire and Comfort modes 20 21 C 2 Low temperature is used by the Night mode Background The activated temperature level can be modified by the and buttons Thermometer symbol flashes when modification is taking place please wait until the symbol stops flashing which confirms the modified temperature is set IMPORTANT Changes in ambient temperature are normal with electronic thermostats when there are variations in the power reguired or when conditions outside the room change The setting is appropriate only for radiators installed in standard environments It is norm
10. ching and installation must be fully compliant with all the regulations regarding installing electrical appliances in a bathrooms potential splash areas see page 4 for further details In such areas to ensure full compliance with applicable regulations and personal safety you must seek advice from or commission a qualified electrician to install this unit To prolong the life of all electrical components turning this appliance on and off should be done using the On Standby button not via the main power source switch this causes sudden jolts of power which are harmful to the electrical components REPAIRS ALTERATIONS This product must not be altered or modified in any way Any necessary repairs must only be undertaken by an INTELLI HEAT approved electrician or by an electrician with the full prior authorisation from INTELLI HEAT If the cable becomes damaged or needs extending any repair replacement or extending the cable must be done by an INTELLI HEAT approved electrician or by a gualified electrician familiar with such products All Instructions to be observed and the correct cable must be used with pilot wire black live and neutral wires In the event of the programmer unit malfunctioning or becoming damaged this entire unit must be replaced by an original programmer unit supplied by INTELLI HEAT no individual spare components are available The CALI Avanti UY au P24 PROGRAMMER DESCRIPTION NOTE This programmer has
11. d the circuit must be easily accessible Briefly explained all electrical connections switching and installation must be fully compliant with all current regulations regarding the installation of electrical appliances in a bathroom or a potential splash area therefore we strongly advise that only a qualified electrician should install this unit in such an area Power supply for single phase current 230V 50 Hz The connection must be made in compliance with the regulations in force before connecting the electric resistance to the line check the voltage and power values indicated on the data plate WALL MOUNTING GUIDELINES PLEASE NOTE Rawlplugs and Screws for fixing the mounting brackets to the wall are not included due to the unknown construction of the wall that you intend to fix this heater to It is essential that this heater is mounted to the wall level and securely using the appropriate rawlplugs and screws When mounting the radiator the top bracket arms slot between the last two vertical elements each side of the radiator with the top and bottom horizontal element bars of the radiator resting on the bracket arms A to E Measurements in millimetres was a Te e o E so 400 500 155 80 700 MEG 1200 555 500 235 80 700 1500 715 500 400 20 700 1800 950 500 480 80 700 Foor CALI Avanti Specifications Watts Height mm Width mm Depth mm Weight Kg Product Code 950 580 610 90 15 CAV
12. four buttons and a display Fig 1 The ON Stand by button switches the regulator ON or puts it on standby When on standby the display shows a flashing dot while when it is ON the display shows the time and program in the Chrono mode or the temperature setting in the other modes Fig I Fig 2 E Mode Icon as set tb gt Display a Thermometer symbol 4 JE JO FT TERRA MAKE Function button gt W ON Standby button Plus scroll button WORKING DESCRIPTION Minus scroll button This programmer has six modes Radio for RF models only Chrono Pilot wire Comfort Night and Antifreeze To change the current mode press the FUNCTION button ICON MODE DESCRIPTION FUNCTION RADIO Set for receipt of radio signal commands settings from a wireless central control unit not applicable to this product All the pilot wire commands except STOP are disabled SIGNAL This mode to be set to enable seven day programming Shows the weekly and hourly CHRONO l programming schedule at two temperature levels Comfort high and low night as set CLOCK by the user All the pilot wire commands except STOP are disabled Programming and all settings will depend on the Pilot wire programmer Operates to PILOT WIRE six commands Comfort Reduction high temperature 3 5 C Stop Frost Protection 7 C Eco 1 High Temperature 1 C and Eco 2 High Temper
13. ing colour coded wires BROWN LIVE LINE E ia re GREY or BLUE NEUTRAL BLACK PILOT WIRE The T 3 black wire is a signal wire for connection to an external X pilot wire programmer do not connect it to any EARTH 5 LIVE or NEUTRAL terminal this will at some time destroy j the thermostat If not used it must be properly insulated ZONE ON El ZONE A D Du E mer G aud IP24 DB ie IP 24 Rated only install outside Zone 2 L_ o Technical installation guidance relating to bathrooms and potential splash areas The following information is a guide to help you understand where this radiator can and cannot be placed with special regard to bathrooms and any other potential splash area such as a kitchen This is not an installation guide therefore for complete assurance reference should be made to the IEE Wiring Regulations 17th Edition or the most recent Edition amendments in place when installing this product or a qualified electrician Bathrooms and potential splash areas are considered to be special locations for electrical installations because they have an increased risk of electric shock for the users due to the proximity of water Firstly it is important to understand the rating by which electrical appliances are classified IP stands for Ingress Protection and relates to the standard EN 60529 an international classification system for the sealing effectiveness of enclosures of electrical equipment against
14. materials or accessories have been used Non observance to these guidelines and all applicable regulations may invalidate the warranty This radiator is filled with a special Thermodynamic Fluid Any repair involving opening the access to this fluid must be carried out by an electrician approved by the manufacturer The manufacturer must be contacted in the unlikely event of any leakage of this fluid Please note that all regulations for the disposal of heating fluid and electrical appliances must be fully adhered to If the cable or any other electrical part fails or becomes damaged repair or replacement must be carried out by an electrician approved by the manufacturer or by a suitably qualified experienced electrician familiar with such products who has the necessary instructions This product must not be positioned below an electrical socket and all applicable regulations relating to the installation of electrical appliances must be fully adhered to See pages 4 amp 6 for further information and guidance During operation it is normal for the radiator to make minor clicking sounds due to metal expansion contraction and for one end fin or one each side not to heat up this allows the flow and expansion of the thermodynamic fluid 3 BATHROOM SPLASH AREAS INSTALLATION GUIDELINES THIS PRODUCT IS DOUBLE INSULATED Therefore amp Dem koer connection to Earth is prohibited The cable contains the sit n AASA fn A follow
15. the intrusion into the equipment of foreign bodies such as dust fingers tools and moisture This classification uses the letters IP followed by two or occasionally three further digits and this indicates the degree of protection provided The higher the number the greater the protection The first digit relates to the degree that persons are protected against contact with moving parts that could prove hazardous and also the degree that equipment is protected against solid foreign bodies intruding into the unit The second digit is the most relevant to electric radiators this indicates the degree of protection against the harmful entry of various forms of moisture The diagram above shows a bathroom split into three clear zones 1 2 and 3 Zone 3 has been withdrawn From the 17th Edition of the regulations Zone O is inside the bath or shower itself any electrical fitting installed in this zone must be rated at least IP67 which is total immersion proof This product is IP24 rated If you intend to install this radiator in a bathroom or a potential splash area to ensure compliance with the current regulations and personal safety it must be positioned outside zone 2 In addition installation must be compliant with the latest IEE regulations which includes the stipulation that the electric supply circuit of the radiator must be protected by a 30 mA RCD protected circuit the opening distance between the contacts must be greater than 3mm an
16. upplied fitted with a plug We recommend connection to a power supply via a switched fused spur 13 amp However fitting a 3 pin 13 amp fused plug for connection to a power supply via a power socket is also acceptable Either way do not connect the black wire to any terminal In most cases this electrical appliance one or several does not need to be powered by a dedicated circuit power supply therefore it they can be connected to powered by an existing 13 amp circuit ring provided that taking into consideration all other electrical appliances powered by that circuit the combined power loading amps on that circuit ring is comfortably below the power supply amps to that circuit For any installation involving direct connection to a power source electrical circuit that electrical circuit must be turned off from the main circuit breaker fuse board before you start any such work For example but not restricted to connection by installing connecting to a switched fused spur Although installation is usually very simple it must comply with all applicable IEE Wiring Regulations 17th Edition or the most recent IEE edition any amendments in place when installing this product If in doubt you must seek advice from or commission a gualified electrician to install this unit If you intend to install this appliance in a bathroom or a potential splash area RCD protection is essential and the wiring positioning and all electrical connections swit