1. Spare parts Apppendix B Technical data 1 Introduction Note these instructions should be read carefully and retained for future reference Please leave these instructions with the user This guide covers the following appliances e Torch framed e Torch framed Propane LPG Special features e Special patented Torch flame technology e Multi vent appliance for wall connection only e Remote Control option available e Meets the essential requirements of the European Gas Appliance Directive GAD and carries the CE mark 1 lt lt 2 Safety Instructions Before installation ensure that the local distribution conditions identification of the type of gas and pressure and the adjustment of the appliance are compatible This gas appliance is factory set and can not be adjusted This appliance does not contain any component manufactured from asbestos or any asbestos related products The pilot and flame sensing device fitted to this fire is also a safety device If for any reason any part of the pilot assembly is to be replaced the entire assembly including the pilot burner thermocouple electrode and injector must be exchanged complete for a pilot assembly from the original manufacturer only Ventilation This appliance is room sealed and doesn t reguire purpose provided ventil
2. Gas connection Installation pipes should be in accordance with BS 6891 Pipe work from the meter to the appliance must be of adeguate size The complete installation including the meter must be tested for soundness and purged as described in the above code A means of isolation must be provide in the supply to facilitate servicing The connection should be made in 8 mm copper or similar semi flexible tube max 1 meter Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls The gas connection is nut and olive suitable for 8 mm pipe Make sure there is a gas connection with a diameter of 8 mm goes directly from the gas meter to the appliance with a CE approved sealing valve G 1 2 This valve has to be accessible at all times Check the connection for gas leaks Mount the supplied nut and olive of 8 mm directly on the gas unit Then you can go on installing a fixed or flexible connection This has to be CE certified When installed as described above the burner can always be disassembled for servicing 4 2 Installing the appliance Check if the wall is sufficiently level If necessary improve it Insulate the back wall if necessary with promatect or comparable inflammable material Position the saddle and mark the hole centres on the rear wall drill the wall and attach saddle using three screws and nylon inserts see figure 1 and 2 Place the appliance on the Saddle mark
3. the hole centres for the Top Clamps see figure 3 Remove the appliance and drill the holes for the clamps Using two screws and nylon inserts fit the clamps to the wall with the clamps slid up the screws Replace the appliance onto the saddle and attach to the Top Clamps Insert the screws to retain the appliance to the saddle Tighten all screws with the Gap behind the appliance maintained and the appliance level Prepare the gas connection Attach the Front Frame This sits on the lugs on top of the appliance and fixes to the saddle at the bottom using 2 screws see figure 4 gt gt 4 5 Commissioning Functional checks Always apply these tests before handing over 5 1 Pilot ignition check e Ignite the pilot light as described in the user manual e Check if the pilot burner stays alight e Extinguish the pilot burner 5 2 Check functional burner and pilot burner The appliance is preset to give the correct heat input No further adjustment is necessary Always check the inlet pressure and burner pressure e Turn off the gas valve on the appliance e Turn the inlet pressure test point C and apply the manometer e Check if the measured pressure is the same as the prescribed pressure e Perform this measuring when the appliance burns on full capacity and when only the pilot ignition burns e When the pressure is too low check if the gas pipes are made of material with the right diameter e When the pressure is too high more than 5 mB
4. 602
5. Torch framed 7090 1950100 Installation Guide CD faber 2 tadi I e 20 OOZuu 8 E en PS 3 f 7 Y si 4 A KS 8 fl S 1 EE M ore A 98ZI 8 A T 3 sl I eZ 185 LEG UIU AM i NW Y 2 1 lt lt je O Sc gt gt gt 2 Content 4 55 5701874 0 5 A A EE 2 Safety INStrUCtl ON S 335s uuu asss RN EN NN EN KIA BB LB NING 3 Installation reguiremehts on I 3 1 Rear s rface CON tr UC ONE SN REK BLN 3 2 Dimensions of the appliance 4 Installation Instructions 2 u suu kavu T BEE 4 1 Gasieconnection 22 ss weaves vie Q amas RE NN NBL qki upas usa 4 2 Installing the appliance 5 Commissioning Functional checks ocoooocoooo oooooooooo rer rr rr rr 5 1 Pilot ignition CHECK as ostes coc EE EE UEA NS i 5 2 Check functional burner and pilot burner 6 SERVICING 253445 ed cides Rene a am eee qa Salen owen a pba NG te todas aw RS re rd qosa apupa pasaq Aa 6 1 ROUTING servicing u nan Hes EE 6 2 Comb stian te Appendix A
6. ar overpressure you can t install the appliance and you should contact your gas company e Always check the burner pressure when the functional pressure is right e Open the burner pressure test point D e The pressure should match the described pressure If this is not the case then contact the supplier Note After checking the burner pressure the inlet pressure test point has to be shut and checked for gas tightness 5 lt lt 6 Servicing To ensure safe and efficient operation of the appliance it is necessary to carry out routine servicing at regular intervals It is recommended that the fire is inspected serviced by a competent person at least once a year Important turn off the gas supply before commencing any servicing Always test for gas soundness after refitting the appliance The appliance and flue connection have to be checked for gas and smoke soundness after installation 6 1 Routine servicing Clean if necessary e the pilot system e the burner e the combustion chamber e the glass e Do the functional tests e Check the flue system and terminal on damage and soundness visual inspection 6 1 1 Cleaning the glass Depending on the intensity of use you can get a deposit on the glass Normally this can be removed with an ordinary dry towel If necessary special ceramic glass cleaner ceramic cook top cleaner can be used To clean the glass e Remove the Front Frame e Remove the glass in it s frame e Clean
7. ation Never use the appliance if it has a broken glass General safety It is the law in the UK that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant British Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions Always use an additional guard if there are elderly infirm or children in the same room of the appliance The installation should also be carried out in accordance with the following where relevant e BS5871 Part1 e BS5440 Parts 1 8 2 e BS1251 e Building Regulations Document J as applicable e Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department e In the Republic of Ireland installation should be carried out in accordance with IS813 ICP3 15327 Building Regulations Codes of Practice the manufacturers instructions and all other regulations in force Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty gt gt 2 3 Installation reguirements Note Since the appliance is a source of heat circulation of air occurs Therefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materials carpet etc will
8. be attracted These components can settle themselves down onto cold surfaces in the form of soot As on all heat producing appliances soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured This should be born in mind when installing the appliance 3 1 Rear surface construction The rear wall upon which the appliance is to be fixed must meet these general reguirements e The rear wall must be of a non combustible material see figure 1 for drilling patern e Minimum distance from the back of the appliance to the wall has to be 22mm This gap should be maintained by the mounting brackets which fit flush onto the rear wall e Theplaster has to be resistant to a high temperature Therefore use plaster materials especially made for this to prevent discolouring min 100 C temperature resistance e Make sure any plaster dries well before using the appliance Let the thickness in mm be the number of days the plaster has to dry e g 3mm plaster has to dry for 3 days e Although the appliance is tested for installation without a hearth the appliance must not stand on combustible materials or carpet e Do not place any material directly onto the appliance e Minimum distance to any combustible material should be either 200 mm or 400 mm see figure 2 3 2 Dimensions of the appliance For the dimensions of the appliance see figure 3 3 lt lt 4 Installation instructions 4 1
9. the glass Handle the glass with clean hands wear gloves if possible e To fit the glass proceed in reverse order Make sure that O the glass sealing rope is in good condition and makes an effective seal O Important be sure that there are no fingerprints on the glass They are burned in the glass when not removed 6 7 2 Cleaning the combustion chamber and burner You can clean the combustion chamber with a vacuum cleaner and soft brush If the burner is visibly damaged this can affect the performance of the appliance If so then replace the relevant parts gt gt 6 6 1 3 Burner dis assembly e Turn off the gas supply to the control valve e Remove the glass and grid e Detach the gas connection e Unscrew the two screws under the burner assembly and remove it from the combustion chamber see figure 7 e The pilot can be removed by removing the screw in the centre of the pilot e Replace parts as necessary and re assemble 6 2 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to MantleBS7927 positioned in the outlet The performance of the appliance should be checked 6 2 1 Procedure for performance test Ignite the fire and run at FULL for a minimum of 15 minutes Record the Carbon Dioxide CO2 reading at the outlet most analysers will display this as a percentage Repeat test for Carbon Monoxide CO this will be measured in Parts Per Million ppm Calculate the combus
10. tion ratio CO CO2 Ratio CO ppm CO2 x 1000 This combustion ratio of the emitted gasses should not exceed 0 0015 7 lt lt Appendix A Spare parts Description Glass Burner Natural gas Burner Propane Remote assembly Gasvalve HT Lead Spark electrode Pilot Burner assembly NG Thermocouple Natural gas 04510930 20861096 20604500 37003098 06017301 06006500 37001030 37002041 Propane 04510930 20532935 20604500 37003098 06017301 06006500 37001030 37002041 gt gt 8 Apppendix B Technical data Country Categorie Appliance Appliance type Reference gas Input Nett kW Efficiency class Inlet pressure mbar Gasrate 15 C amp 1013 bar m3 h kg h Injector size mm Pilot assembly Type Code Outlet terminal size mm Gas control Remote control Batteries remote Batteries receiver Gas connection 9 lt lt UK II2H3P Torch framed C11 G20 2 2 2 20 0 260 1 20 SIT 145 Nr 30 150 100 Mertik GV36 Mertik G30 ZRPS 800 1x 9V MN1604 6LR61 4x 1 5V LRO3 Alkaline 8mm nut amp olive UK 112H3P Torch framed C11 G31 2 2 2 37 0 16 0 8 SIT 145 Nr 15 150 100 Mertik GV36 Mertik G30 ZRPS 800 1x 9V MN1604 6LR61 2x 1 5V LR03 Alkaline 8mm nut 8 olive faber www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 40010567 0