Contents

1. Noise Measured at 80 dB of gain with 200 ohm input termination without 20Hz to 20kHz to assist in filtering out noise 49dBu with final output stage at 50 EIN 129 dBu 46dBu with final output stage at unity EIN 126 dBu 56dBu without final output stage EIN 136 dBu Controls either flat or switched out Output Balanced and floating to feed a 600 ohm load Maximum output 26 dBm into 600 ohms or 20dBm into 150 ohms Output impedance 600 ohms balanced source impedance 75 ohms Frequency Response 11 Hz 77 65 kHz 3 dB Level variation is less than 0 2 Distortion 1k Hz 0 0245 All tests results were measured using a Stanford Research Model SR780 signal analyzer and a Fluke 8060a Input signal was 1v rms input signal and 20dBu output signal
2. Chameleon Labs Model 7602 MKII Microphone Preamplifier and Equalizer Owner s Manual 704 228 Avenue NE 826 Sammamish WA 98074 206 264 7602 www chameleonlabs com Revision A June 2008 Chameleon Labs Your Model 7602 MKII microphone preamplifier has a transformer balanced input with a range between 20dB and 80dB of gain The separate line input is transformer balanced and accepts input levels from 20 to 10dB The equalizer section is a selectable 3 band design with a flexible filter section The Model 7602 MKII has been carefully constructed and individually tested for quality It utilizes pure class A circuitry This unit is made with 100 discrete components hand wound transformers and was fabricated to precisely match vintage counterparts manufactured in the early to mid 70 s The Chameleon Labs Model 7602 MKII is based on high audio performance design techniques By employing classic circuit design polystyrene capacitors a gold contact gain selector and custom wound transformers Chameleon Labs ensures that the Model 7602 MKII will exhibit classic audio sound Your Model 7602 MKII represents a dramatic breakthrough in delivering vintage audio performance at an affordable price Features of the Model 7602 MKII Fully balanced transformer mic input and output Balanced XLR outputs Hi Z direct inputs for instruments on the front panel 48VDC phantom power selector on the front panel 20 position g
3. ed on The second LED indicates the presence of signal The third LED indicates the presence of a 4 dB signal The fourth LED indicates the presence of a peak amplitude signal Filter This is a high pass filter with 3dB loss at 300Hz 160Hz 80Hz and 50Hz with an 18dB cut per octave slope Low Equalization This section has a shelving slope with four frequency selections 220Hz 110Hz 60Hz and 35Hz This equalizer affects the selected frequency and all others below it Mid Equalization This section has a peaking characteristic with six frequency selections 360Hz 700Hz 1 6k 3 2k 4 8k and 7 2k The gain control provides 20dB of boost or cut High Equalization This section has a shelving characteristic with five frequency selections 16k 12k 7k 4 9k and 3 4k This section adjusts the selected frequency and all others above it The gain control provides 20dB of boost or cut Output Acting as a console fader this control is placed after the gain stage and before the output stage This allows for trimming of the input signal between the 5dB steps of the input switch as well as allowing the input to be intentionally overdriven The normal position for this control is wide open Connecting the Preamplifier Equalizer Audio Connection Microphone input connections are made with the female XLR connector on the rear of the unit This connector is wired with pin 2 HOT pin 3 common and pin 1 is ground sh
4. he input XLR on your recorder or D A W If you are sending to a device that does not have a gain control use the Output control to adjust your signal so that your loudest signals just fail to reach the maximum input levels on your recording device 4 Turn the Output control clockwise until you can see level on the input of your recorder Increase until the desired level is achieved Vintage Hint Adjusting the Microphone Line sensitivity control along with the Output control can provide a variety a different sounds by overdriving the amplifier circuits while lowering the final output level in order to not overdrive the recorder 5 If you wish to connect the equalizer section to the line output of your board or D A W simply connect to the female Line Input XLR on the rear panel 6 When an electronic instrument such as an electric guitar is used it may be plugged directly into the 4 DI plug located on the front panel Toggle the DI switch to select this input device 7 If phase reversal is needed toggle the phase switch a zero symbol with a diagonal line through it 8 To insert the equalization section into the circuit toggle the EQ switch Each section can be set to OFF with the frequency selector knob As you add or subtract gain within the equalizer be sure to adjust your overall gain with the output control When the output control can no longer make the adjustments that you need you may switch to a higher or l
5. ield The 48 VDC power is supplied on pins 2 and 3 The Instrument DI connection is made using the balanced 4 TRS jack on the front panel The connector is wired with the TIP being positive The RING being negative and the SLEEVE being ground shield Line input connections are made with the male XLR connector on the rear of the unit This connector is wired with pin 2 HOT pin 3 common and pin is ground shield Output connection is made using the male XLR connector on the rear of the unit This connector is wired with pin 2 HOT pin 3 common and pin is ground shield Power Supply Connection The unit is supplied with a country correct AC adapter All DC conversion regulation and filtering is done within the 7602 MKII The output of the AC adapter is 24VAC and connects to the rear of the unit Optionally you may use the CPS 1 Power Supply to power this unit The unit will auto select which power supply is connected so there is no user required action The CPS 1 uses a 4 pin screw on type connector to provide power to run the Model 7602 MKII unit A Model CPS 1 power supply is optional to power this unit The CPS 1 power supply contains a toroidal transformer to reduce 60Hz hum To insure quiet Operation mount the power supply at least one rack space away from the Model 7602 MKII main unit and locate the AC adapter as far away as is practical The Model 7602 MKII does not come with an interconnecting DC cable that w
6. ill connect it to one of the two power outputs on the CPS 1 If you order a CPS 1 for this unit please be sure to ask for the DC cable to be included A CPS 1 will power two Model 7602 MKII units Be careful when connecting the power cable to insure correct mating of the two connectors They are keyed and should go in with very little effort and then screw down for added safety If more than gentle pressure is required it is 8 possible that the plug is misaligned and should be rotated for a correct fit DO NOT FORCE the power connector The power pin is wired as follows Pin 4 is Audio Ground shield Pin 3 is 48 Volts D C Pin 2 is 24 Volts D C Pin 1 is 24 Volts D C First time users Set up of the Model 7602 MKII 1 Select 40 dB on the Microphone Line sensitivity control Turn the Output control fully counter clockwise Make certain that the DI 48V EQ and Phase switches are all off 2 Connect a microphone to the Female XLR plug on the rear panel If the microphone requires Phantom Power switch the 48V on The normal position for the 300 1 2K Ohm switch is 1 2K This matches most professional microphones used today if you have microphones that require a lower impedance you may toggle the switch to 300 You can toggle between the selections without damage to the microphones to determine which impedance performs better for your application 3 Connect the male Line Output XLR connector located on the rear panel to t
7. old contact rotary gain switch for both Mic and Line sections Output level control functions as a fader when going straight to tape Oversize power supply provides many times the current needed for optimum sound quality and will power two units One year warranty Front Panel Controls Left to Right Switch general rule When the switch is moved toward the function label the feature is selected Power This switch applies power to the unit When the optional CPS 1 is used this switch is inoperative and the power is controlled by the switch on the CPS 1 300 1 2K Ohm This switch selects the microphone input impedance to either 300 or 1 200 Ohms 48V Switch This switch supplies 48VDC Phantom Power to the Microphone Input XLR jack DI Switch This switch routes the Direct Input jack into the unit Microphone Line sensitivity This pot controls input level for the microphone and line inputs The microphone and line inputs have their own input connectors on the rear panel and a separate input transformer Each rear input has its own section of the control on the input gain selector switch The microphone section provides 20 to 80dB of boost in 5dB steps and the line section provides 10 to 20dB of adjustment EQ Switch This switch turns the equalizer section on Switch This switch reverses the phase of the unit 180 Four position LED array The first LED indicates that the unit has power turn
8. ower gain setting on the Microphone Line sensitivity control 11 9 When the optional CPS 1 is used the POWER switch is inoperative and the power is controlled by the switch on the CPS 1 Warranty and Liability Your Chameleon Labs product is warranted to the original owner for a period of one year Chameleon Labs guarantees this product to be free from electrical and mechanical defects and will repair or replace defective components or replace the microphone at Chameleon Lab s option Should service be required for your Chameleon Labs product please contact the manufacturer Service is provided for products beyond the warranty period Seller warrants that the goods are described in this agreement but no other express warranty is made in respect to the goods The entire risk as to the quality and performance of the good is with the buyer Seller disclaims all warranties either express or implied including any implied warranty of merchantability or fitness for a particular purpose and seller neither assumes nor authorizes any other person to assume for it any liability in connection with the sale of said goods MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE PURCHASED FROM Specifications Input impedance Microphone 300 or 1 200 ohms Line 10 000 ohms D I 100 000 ohms Sensitivity Microphone 80dBm to 20 dBm in 5dB steps for 0 dBm output Line 20 dBm to 10 dBm in 5 dB steps for 0 dBm output

Download Pdf Manuals

image

Related Search

Related Contents

Pyle PMKS15  MS40+ Single Stage Rotary Vane Pumps  InstallatIons- und BetrIeBsanleItung  SERVICE MANUAL Colour Television  Proel DHPA120  User Guide for eXport - List Based Testing  User Manual iManager & Software API  Speco Technologies CVC230HZ User's Manual  important  Dimplex R10/73 User's Manual  