Clinician`s Guide PCA THERAPY

image

Contents

1. 11 ACCEPT OPT Press YES to accept any changes made HOW TO CHANGE THE LOCK SETTING Lock may be initially selected in BIOMED SETUP When infusing press OPTIONS key Scroll to LOCK and press NO to change Enter access code at prompt Select the appropriate Lock Setting Press YES ENTER to select Exit Options menu by pressing YES at ACCEPT OPT field INSTALLING BATTERIES Turn pump OFF or connect to AC adapter 2 Open the battery door on the back of pump by depressing the release pin with a small coin and sliding it in a downward motion Install 2 new C size alkaline batteries with both positive poles at the top of the battery compartment Slide the battery compartment door back into place USING THE HELP FUNCTIONS When programming press the HELP key While running press PAUSE then press HELP key When a HELP screen is displayed and there is more text to read that is not displayed on the screen or icons will appear scroll up and down the text using the ARROW keys When finished press the HELP key again to exit the HELP screen CURLIN MEDICAL LLC 15751 Graham Street Huntington Beach CA 92649 Tel 888 287 5999 www curlinmedical com Reorder No 350 9019 2001 2003 Curlin Medical LLC All rights reserved 08 03 Rev D PUMP ALARMS amp RESOLUTIONS LCD DISPLAY RESOLUTION INFUSION Press PAUSE add another IV bag select COMPLETE REPEAT Rx and confirm fields or turn the pump off ALARM Remove air fro
2. Versions 39 and higher Not available on the 2000 Series
3. ue Please center the tubing in the pumping area when installing the administration set PRIMING THE SET CAUTION Disconnect set from patient s access site before priming By Gravity 1 Twist and remove breakaway tab from Flow Stop 2 Squeeze Flow Stop between thumb and forefinger to allow fluid to flow through tubing Electronically Note Set must be installed into the pump 1 Release any clamps on the administration set 2 Press and release PRIME key from Run Options menu 3 Press and hold the PRIME key until set is free of air release key to stop each prime cycle allows up to 6 ml of fluid 4 When prime is complete press YES ENTER to exit the prime screen PROGRAMMING FOR PCA THERAPY Turn the pump on Observe the self test the LED lights and the power source screen Select PROGRAM from the first selection menu If multiple therapies are available select PCA from the therapy selection menu Complete the pre prescription menu Mo unr A UNITS med UNITS ML I ONCENG ma m CONCEN O O mcg nl fe ADMIN Rt TU AMIN Rt EPL LOAD DOSE mg LOAD DOSE meg Titrate ON Titrate OFF NEXT YES Titrate OFF NEXT YES NEXT YES 6 Complete the prescription menu B ens Vol ERE ral BAG Vol EREN ml BAG Vol EAEN ral WEASLRATE ml he EASLRATE o mothe eASLRATES megh i Bolus 2 8 ml BOLUS O ma BOLUS meg BOLS INT MIN BOLS INT MIN BOLS INT
4. CURLIN MEDICAL 4000 Series and 2000 Series Ambulatory Infusion Pumps Clinician s Guide PCA THERAPY REFER TO USER S MANUAL FOR DETAILED INSTRUCTIONS Pump Door Pump Door Instruction Label Display Door latch Screen L Run Pause On Off Key Key Help Option Key Data Interface7 Bolus Cord Port LED Status Indicator Down Arrow Yes Enter Key Up Arrow Prime Bolus No Change Key Key Decimal Point Numeric Keys Silence Key KEYPAD FUNCTION ON OFF Turns pump on and off When the pump is running the PAUSE key must be used to stop infusion first Then press the OFF key to turn pump off RUN PAUSE Starts or pauses the pump When the pump is paused pressing this key will resume pumping UP ARROW DOWN ARROW Used to scroll through the display screens NO CHANGE Rejects highlighted data YES ENTER Accepts highlighted data HELP OPTIONS Used to request and exit help screen when pump is paused or go to options screen when pump is running SILENCE Used to silence alarm for 1 minute intervals and as a decimal point PRIME BOLUS Used to prime fluid through the tubing to clear it of air LED INDICATORS Green pump is running Yellow standby Red pump in alarm status SETTING UP THE PUMP Install 2 new C size alkaline batteries or connect Battery Pack or AC adapter to bottom of pump Prepare IV bag and attach a new administration set 3 Eliminate all air fr
5. MIN EOLSihe A DONE YES 7 Make selection from run option menu PRESS to START to REVIEW or Haia 8 Press NO to review prescription OPTIONS to view options menu PRIME to prime set or press RUN key to start infusion 9 While PCA infusion is running the display will alternate between various information screens 10 To interrupt or pause an infusion press RUN PAUSE key 11 Make selection from the pause menu PEUTER to Select mereen RE NEN SRORRAeg A 12 When the infusion is complete the following screen displays TOT VOL 20 8 mal BOLUS of i INFUSION COMPLETE 13 To stop a therapy press PAUSE then turn pump off OPTIONS LOCK Press NO to change Lock Setting may need access code Press YES to accept new setting CLINICIAN DOSE Press NO to change YES to accept enter dose amount and press YES to accept SHIFT TOTAL Press NO then YES to view Press YES to exit To CLEAR press NO at EXIT then YES to CLEAR HOURLY TOTAL Press NO then YES to view Scroll to review Press NO to exit CLEAR HOURLY Press NO then YES to view Press YES to clear NO to retain and exit TITRATE Appears only if previously selected Press NO to change YES to accept enter new rate and press YES to accept DOWN OCCLUSION Press NO to change YES to accept AIR SENSITIVITY Press NO to change YES to accept AUDIO Press 1 9 to hear level press YES to accept 10 POWER CHECK Press NO then YES to check level
6. m administration set and IV bag AIR IN LINE Disconnect set from patient s access site prior to using prime function ALARM Check administration set from the pump to DOWN patient s access site for cause of occlusion OCCLUSION Correct obstruction per protocol Consider changing the pressure setting from Low to High When occlusion is resolved the alarm will stop and pumping will resume ALARM Check administration set from IV bag to pump UP for cause of occlusion When ready to begin OCCLUSION infusion press PAUSE select RESUME and press RUN ALARM Check for excessive pressure on IV bag When HIGH UP ready to begin infusion press PAUSE select PRESSURE RESUME and press RUN ALARM Install appropriate Curlin Medical administration SET NOT set Use ONLY Curlin Medical administration INSTALLED sets See User s Manual or IV set directions for proper installation instructions ALARM To resolve press RUN and resume the therapy UNATTENDED or continue with operating procedure PUMP ALARM Replace set prime set if necessary select REPLACE SET RESUME and press RUN when ready to begin ALARM Check placement of administration set and close DOOR OPEN pump door properly See Users Manual for instructions ALARM Press the pause key and turn pump off Install 2 EMPTY new C size alkaline batteries BATTERY ERROR CODE J If an error code occurs turn pump off then back on If it reoccurs notify dispensing agency
7. om the bag and the administration set see PRIMING THE SET 4 Install set and close pump door 5 Attach set to venous access device using agency protocol Note If a Check Valve Adapter is provided with your administration set remove it from the package and connect it to the distal end of the set INSTALLING THE ADMINISTRATION SET Fully open the door of the pump 2 Close the slide clamp on the administration set Activate the Integral Flow Stop by twisting and removing the breakaway tab Insert the blue tubing guide into the receptacle on right side of pump in the direction of the blue arrow positioning the tubing in front of the door hinge Center the tubing in the middle of the pumping fingers covering the yellow dot Holding the yellow Integral Flow Stop by the handle insert it on an angle into the receptacle on the left side of the pump in the direction of the yellow arrow CAUTION Do not press down on the top of the Integral Flow Stop when inserting it into the receptacle This action could inadvertently open the Integral Flow Stop and allow fluid to flow through the tubing Open the slide clamp on the administration set Push the tubing slightly into the black Air Detector slot Fully close the door of the pump and latch it securely Air Detector Flow Stop handle Important Notification A lack of compliance with proper positioning of the tubing could result in infusion inaccuracies m