Home
1 NEW IM NEWINIATURES SERIES CAIRCLI NEW MINIATURES
Contents
1. breath A quiet area is best to stabilize the measures It is prohibited to immerse Cairclip In the case of accidental splashing with water drain and wipe the Cairclip immediately with a clean and dry cloth Do not used the CairClip at height upper than 2000 meters Use standard batteries recycling method at the end of the 12 month end life Battery not exchangeable Do not expose Cairclip to very dry air lt 5 humidity or to high concentrations of gases such as combustion gases exhaust of vehicles gas stoves boilers dryers gas cigarettes smoke Solvents glue paint or chlorine Acidic or basic vapors Steam and water saturated vapor Breath sauna Hammam VIII INTELLECTUAL PROPERTIES The Cairpol name the logo Cairpol the names of products in its family as well as the slogans and the technology developed by Cairpol are unless otherwise stated trademarks and patents Any reproduction use and or modification made without Cairpol prior approval is likely to constitute an infringement IX CONTACT For more information don t hesitate to ask CAI RPOL Avenue Olivier de SERRES Centre Commercial Rocade Sud 30100 ALES FRANCE Phone 33 0 4 66 83 37 56 E Mail info cairpol com X WARRANTY CONDITIONS CAIRPOL A SARL au capital de 354 200 N Siren 492 976 253 Avenue Olivier de Serres Centre Commercial Rocade Sud 30100 Ales France T l 33 0 4 66 83 37 56 info cairpol com www
2. cairpol com AIR MINIATURE AIR MONITORING SYSTEMS Cairpol Devices are guaranteed 12 months parts and labor Beyond 12 months the operation of the Cairclip may not be sufficiently accurate and it is advisable to replace it Opening of the device by unauthorized personnel will invalidate any warranty While following the safety rules and operation described in the present manual you have noticed what you believe is an abnormal peak we encourage you in sharing the details of your observations in the contact section of our web site at www cairpol com XI APPLI CATI ON gt For general public Thanks to its small size easy to wear and warns in real time the level of pollutants in the aim to adapt activities avoiding health problems gt For associations school or city hall Thanks to its moderate cost allows to use some to map the air pollution district by district Large colored screen option permits persons group information gt For industries Fixe or mobile with wireless connection and solar panel XII ACCESSORIES gt USB cable for battery recharge on PC or power supply via adaptor and data transfer gt USB plug green on desk functioning red measure mode Time mode exposure gt Adaptor 100V 240V 5V 0 8A 1 0A USB gt Pouch with belt clip gt Recharge filter for 1 year gt Instruction manual e Optional accessories gt Solar panel gt Bluetooth for GSM GPRS XIII MAIN OPTIONS Cairtub autono
3. 15 min the exposure time will CAIRPOL 3 SARL au capital de 354 200 N Siren 492 976 253 Avenue Olivier de Serres Centre Commercial Rocade Sud 30100 Ales France T l 33 0 4 66 83 37 56 info cairpol com www cairpol com AIR MINIATURE AIR MONITORING SYSTEMS be displayed continuously It is advisable to stay far away from the sources How does the Cairclip display a reduction of pollution level and exposure time If the pollution level falls below the threshold corresponding to a pictogram it will turn it off but the decrease in exposure time will only start after 5 minutes in order to compensate for natural variations around the value being measured The total exposure for the day can be displayed on a PC running the CairSoft software by connecting the Cairclip via the included USB cable If you do not have a PC insert the Red USB plug in the Cairclip USB port for 6 to 10 seconds then remove it and the value of the cumulative exposure from morning 0 h will be displayed for 30 s VII SAFETY I NSTRUCTI ONS The Cairclip comes packaged in a waterproof bag to avoid exposition to vapors during transport for example that could harm its operation In the Air quality Units mode between 30 and 1000 ppb of H2S and Mercaptans the accuracy of the Cairclip is LO ppb In the Forced measurement mode between O and 30 ppb the accuracy of Cairclip can be strongly influenced by its environment draft proximity to skin
4. ALIX MINIATURE AIR MONITORING SYSTEMS NEW MINIATURES SERIES CAIRCLIP for H2S amp Mercaptans Instructions for use GENERAL DESCRIPTION Diameter 32mm length 62mm Weight approximately 55g Operating time 24 to 36 Hours when fully charged allow for a recharge each day for optimum use Expectancy life 12 months Included accessories Three filters two USB plugs one USB cable one 100 240V AC adapter a pouch The PC interface software CairSoft is available for download at www cairpol com Il TECHNICAL DESCRIPTION The Cairclip is a device intended for the general public that measures chronic low level exposure of H2S and Mercaptans It continuously measures the H2S and Mercaptans concentration and compares it to different Health Organization Air quality guide line H2S hydrogen sulfide is generated mostly wastewater treatment plant off gases by product of desulfurization processes in the oil and gas industries and rayon production sewage treatment and leather tanning Some materials like drywall can generate H2S too These pollutants are capable of causing respiratory and eyes irritations By knowing the level of a given pollutant in real time you will be able to limit their adverse effects by adjusting your activity level avoid running quiet activities In addition carrying such a device can help you tailor your trips to your personal needs by avoiding polluted areas The Cairclip is the result of re
5. g test in laboratory 20 C 4 2 C 50 HR 10 1013 mbar 5 CAIRPOL 6 SARL au capital de 354 200 N Siren 492 976 253 Avenue Olivier de Serres Centre Commercial Rocade Sud 30100 Al s France T l 33 0 4 66 83 37 56 info cairpol com www cairpol com
6. my 21days Cairnet wireless connexion amp battery powered by solar panel Software cairsoft cairmap cairweb CAIRPOL 5 SARL au capital de 354 200 N Siren 492 976 253 Avenue Olivier de Serres Centre Commercial Rocade Sud 30100 Ales France T l 33 0 4 66 83 37 56 info cairpol com www cairpol com AIR MINIATURE AIR MONITORING SYSTEMS XIV DATA SHEET H S Specifications Limit of detection Repeatability at zero Repeatability at 80 of range Linearity Short term Zero drift Short term Span drift Long term Zero drift Long term Span drift Rise time T10 90 Fall time T10 90 Effect of Interfering species power supply output operating conditions dimensions weight Protection Maximum exposure Annual exposure limit 1 hour average Range 0 1000 ppb 10 ppb 10 ppb 4 lt 5 lt 4 ppb 24h lt 0 1 FS 24h lt 8 ppb 1 month lt 2 FS 1 month lt 90 s 180s if large h variation lt 90 s 180s if large h variation CH3SH 95 other VRSC OCS CoH S C2H6S2 lt 100 5VDC 200mA rechargeable by USB via PC or 100V 240V 5V 0 8A 1 0A with adaptor USB RS 232 or UART on demand 20 C to 45 C 10 to 90 R H without condensation 1013 mbar 200mbar diameter 32mm length 62mm 55g IP 42 according IEC60529 50 ppm 220 000 ppm According to our operating condition durin
7. searches from several laboratories and the implementation of the following Innovative technologies An electrochemical sensor ultra sensitive to H2S and Mercaptans A dynamic air sampling system micro fan that ensures a constant and smooth airflow to the CAIRPOL 1 SARL au capital de 354 200 N Siren 492 976 253 Avenue Olivier de Serres Centre Commercial Rocade Sud 30100 Al s France T l 33 0 4 66 83 37 56 info cairpol com www cairpol com AIR MINIATURE AIR MONITORING SYSTEMS sensor A patented adaptive filter that permits the same level of performance both indoors and outdoors This filter should be replaced after 6 months of use or in case of an accidental blockage mud food A powerful microprocessor that calculates the levels and time of exposure to pollution which can be connected via a USB port to a PC to adjust the devices basic settings name time display style units of measure and to display up to ten months of saved data Iil OPERATION DESCRIPTION The Cairclip requires no adjustments When you receive your Cairclip it will be ready to go on your belt or on the strap of your favorite bag as soon as you remove the red USB cap keep the red cap in a safe place as it can be used to access various menus in the absence of a PC The Green USB plug can be used to protect the USB port if necessary When the battery symbol lights up the device must be charged via USB on your computer or b
8. t VI MEASUREMENT AND ALERTS LEVELS In the original time display mode the level of pollution measured appears on the screen only when a specific threshold is reached In the Air quality measurement mode the concentration of H2S and Mercaptans is given continuously by the 3 digits to the left of the separator 2 points the time of exposure is indicated by 2 digits to the right as multiple of 10 minutes CAIRPOL f SARL au capital de 354 200 N Siren 492 976 253 Avenue Olivier de Serres Centre Commercial Rocade Sud 30100 Al s France T l 33 0 4 66 83 37 56 info cairpol com www cairpol com AIR MINIATURE AIR MONITORING SYSTEMS Battery level fos Val Expo I OLS Jt Wo Eq ppm ppb pg n x10 mn Exposure time by 10 min Exposure in ppm ppb or T Warning Measure impossible How does the Cairclip display a peak of H2S and Mercaptans pollution Below the first threshold of information only the green light flashes 1 level of information threshold equivalent to 30 ppb of H2S amp Mercaptans yellow light flashes Current California Ambient Air Quality standard for hydrogen sulfide based on a 1 hour averaging time and U S Department of Health and Human Services Agency for Toxic Substances and Disease Registry recommended level for 15 to 365 days of exposure 24 hours a day 7 days a week 2 information threshold equivalent to 70 ppb orange light flashing This concern was believed to be s
9. ubstantiated by reports of nausea and headache If this level of pollution is maintained for 3 min the buzzer is activated for 1 to 2 seconds and the pictogram remains visible If this level of pollution is maintained over 15 min the exposure time will be displayed continuously It is advisable to limit its activity 1 warning level equivalent to 110 ppb of H S and Mercaptans flashing red light WHO guideline value If this level of pollution is maintained for 3 min the buzzer is activated for 1 to 2 seconds and the pictogram remains visible If this level of pollution is maintained over 15 min the exposure time will be displayed continuously It is advisable to only engage in quiet activities 2 warning level equivalent to 200 ppb of H S and Mercaptans flashing purple light If this level of pollution is maintained for 3 min the buzzer is activated for 1 to 2 seconds and the pictogram remains visible If this level of pollution is maintained over 15 min the exposure time will be displayed continuously It is advisable to rest 3 warning level equivalent to 600 ppb of H S and Mercaptans flashing maroon light EPA s Integrated Risk Management System published information suggesting children and neonatal animals could be selectively susceptible to neurological effects If this level of pollution is maintained for 3 min the buzzer is activated for 1 to 2 seconds and the pictogram remains visible If this level of pollution is maintained over
10. y using the power adapter The 4 levels of battery charges on the display will remain lit when fully charged about 4 hours The Cairclip will display the time unless the first level of information of 30 ppb is reached Upon reaching this threshold the display will remain in Air quality measurement mode To change the original screen to an Air quality measurement mode simply insert the Red USB plug in the Device USB port for 5 seconds and remove it To return the screen to the time display mode repeat the previous operation IV FILTER REPLACEMENT DESCRI PTI ON The only required maintenance to ensure reliable measures by the Cairclip is to replace the adaptive filter after 6 months Simply remove the old filter by pulling it by its edge and place a new filter in the opening ensuring that no fibers from the filter hinder the operation of the fan The filter replacement operation must be made without touching the white part and in an area free of dust or water to avoid damaging your Cairclip Replacing the filter must be performed at least 12 hours before next use as the filter requires up to 12 hours settling If the filter is not allowed to settle it may damage the integrity of the air quality readings Because of the small size of some components filter removable USB cap the CairClip is not suitable for children under 36 months V LOADI NG CAI RCLI P If you forget to reload your device more than 7 days the data will be los