Home

REED Instruments REED R5003 AC Voltage

image

Contents

1. Datalogger Setup Setup the datalogger RMS sampling rate auto power off and circulate logging Download Store Data Download the data which is stored in the meter Read Real Time Data PC from meter Stop Reading PC stop reading data from the datalogger Import Data To List Show the data as a list Previous Measurement Check the data from last measurement Note After the data is downloaded to a PC the software will overwrite the old data with the new data resulting in only one previous result With this in mind saving every entry is ideal Window Instrument Show or hide the instrument window Info Dialog Show or hide the info dialog window Help About Show the version information of the datalogger software Help Topics Show the software help document info REED Direct com REED DIRECT COM 1 888 475 5235 Operation Correct Time If you find the datalogger time is not correct click the icon to open the correct time dialog Input the correct date time and click OK If the time continues to be incorrect you may need to replace the 3V button battery Datalogger Setup Note Save your data before entering Datalogger Setup All data will be permanently erased from the datalogger if you save any changes in the Datalogger Setup Click on the Bal icon on the menu bar LOGGER RMS SAMPLING RATE SETUP Set the datalogging sampling rate LOGGER AUTO POWER OFF SETUP Turn the Auto Power Off function ON or
2. OFF LOGGER CIRCULATE LOGGING SETUP Turn continuous recording on or off If continuous recording function is on the datalogger will continue to record data when the memory is full overwriting earlier data If continuous recording function is turned off the datalogger will stop recording when the memory is full SETUP button Saves any changes DEFAULT button Set the datalogger to the factory default CANCEL button Aborts the setup info REED Direct com REED DIRECT COM 1 888 475 5235 Download and Store Data To transfer records from the datalogger to PC 1 Connect the datalogger to the computer via the USB cable 2 Open the datalogger software program if it is not still running 3 Click the icon 4 A prompt will appear with a Download and a Cancel button Click on the Download button If the records were successfully transferred a data graph will appear The top field shows detailed information on the RMS readings MODE Current mode selected on the datalogger SAMPLING RATE Sampling rate for these readings START TIME Based on the Clock Settings when the datalogging commenced an DATANO An identification number for this specific download CH1 CH2 MAX MIN The MAX and MIN readings for CH1 and CH2 inputs 7 Click the ST RMS or the ST TR icon to switch the view of the graph data vertically 8 Click the ST TR icon to view a transient wave data graph 9 Double
3. appears on the LCD info REED Direct com REED DIRECT COM 1 888 475 5235 Low battery indication Power supply Power consumption Dimensions Weight Includes Empty battery symbol appears on the LCD 4 AAA Batteries and 1 CR 3V memory button battery CR2032 or equivalent 5 days approximately 4 5 x 2 5 x 1 3 114 x 63 x 34mm 8 70z 248g AC current clamp sensor amp voltage sensor USB cable software and battery Electrical Specifications Voltage 40Hz to 1kHz range 6 to 600 0VAC Voltage 40Hz to 1kHz accuracy 2 0 1V Current 50 60Hz range 50 60Hz accuracy 2 0 1A Current 2 to 200 0A Instrument Description LCD Description 1 Auto power off 2 Recording status 3 Record until full is selected 4 Continuous 5 Memory full and 6 Battery status 1 6 BBBBBE recording is selected recording has stopped au H o Bl ha MAX MIN FULL 4 info REED Direct com REED DIRECT COM 1 888 475 5235 Meter Description 1 LCD screen 8 2 AC adaptor jack 9 3 ON OFF button 10 4 MAXMIN button 11 5 Channel input jacks 12 6 Channel display button 13 7 START STOP button 14 USB port AC current clamp jaw Jaw opening trigger CH plug AC voltage probes alligator clips Voltage module Channel plug gt i hb info REED Direct com REE D DIRECT COM 1 888 475 5235 Operating Instructions 1 Set up the datalogger using the sof
4. click the list items to see each data graph corresponding to the item Import data to Excel List Click the icon to import the data to an Excel sheet The Excel sheet lists specific time and data value corresponding to each type data graph Print Graph and List Click the icon to print the graph Click the En icon to import data to a list then click the icon to print the list info REED Direct com REED DIRECT COM 1 888 475 5235 Save and Open Click the i icon and save the file to the computer with the default extension stdata or rtdata To open an existing data file for viewing on the data graph window click on the icon then select a stdata or rtdata file off the computer Graph Features Zoom To zoom into a specific area on a graph click the left mouse button and drag a rectangle around the area to be expanded and release the mouse button Use the horizontal and vertical scrollbars to scroll through all the data Zoom out to full view by clicking the Undo Zoom button on the top of the graph X Axis and Y Axis To change the X and Y axis coordinates click on the Axis Setup button Y Axis Setup Input the required data values X Axis Setup Input the required data points Click OK and your graph will now correspond to these settings Colour Setup To change the colour of the graph click on the Colour Setup button You can change the CH1 data colour CH2
5. the same button again for more than 4 seconds to stop recording Recording will stop when the memory is full When continuous recording is selected in the software newer data will overwrite the oldest data when the memory is full Datalogging Software Note The datalogger is still running off its internal batteries when plugged into the computer Be sure there is sufficient battery power before plugging the datalogger into a computer or data may be lost or corrupt 1 Place the CD in the CD drive and follow the on screen installation instructions 2 After the software is installed keep the CD in the drive and connect the datalogger to the PC by the USB cable 3 AUSB driver installation window will pop up Follow the directions to install the driver System Requirements Windows 2000 or Windows XP or Vista PC or NoteBook with Pentium 90MHz or higher 32 MB RAM e At least 7 MB byte hard disk space available to install Datalogger USB software Recommended display resolution 1024X768 with High Colour 16 bit info REED Direct com REED DIRECT COM 1 888 475 5235 Main Menu Description Eileif Instrument I Winden Gelp iH 4 22 BB ii 8 8 Fil E Save the recorded data to the computer Open Open a saved file Print Setup Change the printer and printing options Print Preview Print preview the graph or the list Print Print the graph or the list Instrument Correct Time Correct the datalogger TIME
6. R5003 True RMS Current Voltage Datalogger Instruction ecuins Lita info REED Direct com REED DIRECT COM 1 888 475 5235 Table of Contents Safety ii A A A 3 A AR cedaceanezaceeazs 4 SPECIICALONS nen han ke anti nenne nern 4 5 Instrument Description cccccnnnnnnoniconoononononononononnnononononcnconenenananns 5 6 Operating Instructions uunssssnssnnnnenennnnnnnnnnnnnnnnnn nme nennen nn 7 8 MAXIMIN E isa 7 Auto POWER Ok ace 7 RECON att ii ea ao 8 Datalogging Software unnnnennssennnnsennnnnnnnnnnnnnnnnnnnnnnnn nennen ennnn nn 8 12 Main Menu Description ooocconconccinnnnnconccnaconnanaccnnc rana nc nan cnnncn nc 9 Operation 10 Download and Store Data uu suseernnenernnenerenne ernennen 11 12 Graph Feat res ii as 12 info REED Direct com REED DIRECT COM 1 888 475 5235 Safety Do not operate around explosive gas vapour or dust Do not operate in a wet environment Do not operate with any of the parts removed Do not use this unit if it looks damaged Pay attention to avoid short circuits when testing a non insulated cable Never open the battery cover during measurements Do not install substitute parts or make modifications on the meter Never replace the battery in moist areas Ensure the meter is disconnected and switch off before opening the battery cover to replace the battery Do not attempt to place the instrument in high vibration areas Do not expose the meter to di
7. data colour background colour and grid colour Custom View To customize the information that is displayed on the graph click on the View button This allows the user to select which data to view as a trace and the graph type The user can also add or remove grid lines from x and y axis or to mark the data points info REED Direct com REED DIRECT COM 1 888 475 5235 Notes info REED Direct com REED DIRECT COM 1 888 475 5235 Notes info REED Direct com REED DIRECT COM 1 888 475 5235 Notes info REED Direct com REED DIRECT COM 1 888 475 5235 Notes info REED Direct com REED DIRECT COM 1 888 475 5235
8. rect sunlight high temperatures or high moisture environments Switch off the meter after use Remove the AAA batteries when if the meter will be stored for a long period of time When cleaning do not use abrasives or solvents on the meter use a damp cloth and mild detergent only For service on this or any other REED product or information on other REED products contact REED Instruments at info reedinstruments com info REED Direct com REED DIRECT COM 1 888 475 5235 Features 2 channel inputs for simultaneous recording of leakage current load current and voltage Monitor and log data Voltage Voltage Current Current or Voltage Current over long periods of time Easily transfer data to a PC for viewing and evaluation True RMS measurement Max Min 8 Peak modes Max Min alarm mode Time and date display Auto power off USB interface Manual and automatic mode Specifications Operating temperature 32 to 122 F 0 to 50 C Operating humidity lt 70 RH Storage temperature 4 to 140 F 20 to 60 C Storage humidity lt 80 relative humidity Standards CE CAT III 600V inside use max height 2000M Display Multi function LCD Maximum data points 256 000 values Sample rate 1s to 24h selectable Data output USB port Analysis software Windows 2000 XP Vista Channels Dual channel TRMS AC Voltage or Current AC Adaptor 9V 0 5A Clamp jaw opening 0 5 12 7mm Open input indication LO
9. tware provided See Datalogging Software section for more information 2 Connect the voltage test leads or the current probes to the AC source or clamp the jaws around a single conductor for AC cur rent measurements up to 200A 3 Press and Hold the START STOP button for four seconds to start recording The REC icon will appear in the display indicating that recording has begun 4 Press and Hold the START STOP button for four seconds to stop recording The REC icon will disappear from the display 5 Remove the probe connect the datalogger to a PC and use the supplied software to download the data Note If the clock is not set to the correct time you may need to replace the 3V button battery MAX MIN While taking a measurement press the MAX MIN button once to display the MAX maximum reading Press the button again to display the MIN minimum reading A third press will exit MAX MIN mode The meter will automatically exit MAX MIN mode in 10 seconds if no button is pressed Auto Power Off This meter will automatically shut off after 5 mins of inactivity Auto Power Off does not apply when recording info REED Direct com REED DIRECT COM 1 888 475 5235 Recording After Record Mode is set up by the software see Datalogging Software section for more information press the START STOP button for more than 4 seconds to begin recording The REC icon will display and indicates the meter is recording data Press