Home
Advanced Digital Meter
Contents
1. PONSEL MESURE Advanced Digital Meter ODEON Reliability simplicity and flexibility NEOTER PONSEL m ALWAYS READY TO MEASURE Digital plug and play probes m ALWAYS CONFIDENCE Autodiagnostic status always displayed GLP compliance E SIMPLICITY 4 display and intuitive menus E HIGH PERFORMANCES Mono Multiparameters 8 Mo Memory 100 000 data E FIELD INTRUMENTATION P67 pH ORP Dissolved Oxygen OPTOD Optical Technology Conductivity Turbidity Access to high performances with the PONSEL ODEON Digital Handheld Instrumentation A real combination of simplicity flexible reliability and reduced maintenance technologies the ODEON Meters offer you a total confidence in your readings in laboratory and field conditions This range of 6 ODEON Meters are available in the Classic Line single channel meters Open Line Versatile single channel meters X Line Versatile bi channels Meters to meet all yours requirements Probe 2 X Line only Probe 1 Watertight all purpose connectors Clic Loc Plug PONSEL SURE gt ODEON METERS Classic Line One Line and X Line 8 Mb memory Wide graphical screen 4 320 x 240 vA backlighted 7 buttons to access to all functions USB cable Loader supply External supply Ergonomic design for all hand IP 67 Inserts for wrist loop or strap Watertight E User friendly Intuitive menus No user manual req
2. Cable 1 Standard solutions 125 mL standard solutions according parameters Carrying case Outdoor case plastic case shockproof lightweight for 2 probes PC cable Charger and and 4 bottles of standard solution 125 ml PC Software Wintek Viewer gt Accessories Options E Standard solutions 125 mL pH 4 01 7 01 10 01 ORP 240 mV Conductivity 84 uS cm 1413 uS cm et 12 880 uS cm Turbidity Formazine E Cable lengths 7 m 15 m other on demand E Carrying case E Software ODEON Viewer m ODEON Upgrade Classic to Open line m 12 V external power supplv cable
3. nsion D x L Standard Cable lenght MT Weight with 3 m cable Protection Class Se a ee a a Operate temperature 10 C 50 C 10C 50C 10 C 50 C Compatibilty Temperature sensor Interface communication Modbus RS 485 Modbus RS 485 Modbus RS 485 Modbus RS 485 f Inox 316 L or Materia PVCIPOMC PVC POMO PVC POMO ee ee ee Spare oH ORP Cartridge DOdisk parameters pH ORP Dissolved Oxygen satiny Turbidity aranges 0 4000NTU E 1000 0 mV 0 00 20 00 mg L 0 200 0 uS em 0 0 50 0 NTU 2 aa 1000 0 mV Ree Ronen 0 2000 uS cm 0 0 200 0 NTU j 2 0 00 20 00 mS cm 0 1000 NTU 0 0 200 0 mS cm 0 4000 NTU pe Mannual Automatic Manual Automatic Resolution 0 01 pH Oa ae 0 01 to 1 u mS cm 0 1 to 1 NTU mg L 0 1 mg L 1 of the full lt 5 of the full scale Pressure temp Compensation Temperature salinity Mode Off Temperature Temperature Manual Automatic plasticized PONSEL OPTOD C4E Technology 4 PONSEL optical luminescence electrodes 2 IR 90 technology nee Platinum electrode Measurement principe PLASTOGEL technology electrolyte Ag AgCl reference ASTM D888 05 platinum and 2 ISO 7027 compliance Ag AgCl reference Complinace graphite Response time t90 Full range 0 100 gt Standard Set Meter 1 Meter ODEON Classic ODEON OPEN ONE or ODEON X with 4 AA batteries Probes 1 2 3 or 4 Digital PONSEL probes with 3 meters cables Charger 1 230 V Charger ODEON PC
4. probes manufacturing DISSOLVED OXYGEN OPTOD Optical Luminescence Technology E No Calibration No membrane No electrolyte No drift m No cross sensitivity with pH 1 14 CO2 H2S SO2 E Real Time Temperature Salinity and Pressure Compensation E Fast response sensor Light Emission E Body in stainless steel or Titanium PONSEL OPTOD Luminescence technology E ASTM International Method D 888 05 compliance TURBIDITY IR Nephelometry 0 4 000 NTU 0 4500 mg L E R Sensor Optical fiber technology E Precise and accurate measurements m Calibration in mg L E No sampling real turbidity value with direct measurement E ISO 7027 compliance pH ORP m pH ORP Temp sensor m PONSEL PLASTOGEL Plasticized electrolyte E Temperature compensation E Robust field probe E Cost effective only pH ORP Cartridge technology CONDUCTIVITY PONSEL C4E m Conductivity Salinity Temp sensor E C4E electrode E Temperature compensation E Robust field probe E No maintenance PONSEL MESURE gt Datasheets Probes PHIORP T Oxygen T Conductivity T Turbidity T oe Laboratory and field geo and field Laboratory and field Wastewater drinking Wastewater drinking Wastewater drinking Wastewater drinking water seawater water seawater water seawater water seawater rivers natural water rivers natural rivers natural rivers natural OPTOD Conductivity Turbidity Dime
5. uired Models Comfortable and easy to read Large 4 backlighted display E PC USB connection m Easy handling in all situations One X Only 5 buttons for all functions aeS SoC LINE Open LINE m High autonomy Low Power technology Classic Line Open Line Turbidity Models pH IORPT Oxygen T Conductivity 0 4000 NTU 0 4500 mg L Probes compatibility Probe Channels C cE os eat ee EY Yes S O Sensor status Indicator Yes i Autodiagnostic Yes Display Large backlighted graphic LCD 4 display 240 x 320 Automatic switch in economic mode With date time user and sample user C status pressure Simultaneous display of 1 to 7 parameters max Power supply 4 AA batteries or chargeable batteries battery charger needed Autonomy 200 hours with standard batteries in economic mode Interfaces USB RS 485 interface to probes 1 or 2 External 12 V battery Charger Box PC ABS Operate hydrometry PONSEL MESURE gt PONSEL Digital probes m Plug and Play digital probes Your probe is immediately ready to use E High fiability and confidence in your readings Autocheck status and calibration autodiagnostic E Robust probes Outdoor use design for Laboratory wastewater natural water fishfarming applications E Flexible and smart probes Calibration and history data inside Ultra low power probes For long term campaigns m PONSEL Probes 50 years experience in
Download Pdf Manuals
Related Search
Related Contents
Emerson 3300 Radar Detector User Manual NHS Western Isles Communication Book 一括ダウンロード Bijlage 16 Windvi User's Manual コバルトハイスの採用で長寿命イヒを実現 Philips MULTIGROOM Series 3000 QG3334 Mode d`emploi Luge pliable en aluminium avec volant PN-ZS1C Operation-Manual FR Convertitore Corrente Pressione I to P Converter Bedienungsanleitung Copyright © All rights reserved.