Home
Dynamica General Catalog 2012_9_25.indd
Contents
1. 2 Halo UV Detective Software 3 Halo XB 10 VIS 20 UV Visible and Visible Touch Screen Spectrophotometer 4 Halo RB 10 UV Visible Ratio Beam Spectrophotometer 6 Halo DB 20 DB 20S DB 20R UV Visible Double Beam Spectrophotometer 8 Halo DB 30 UV Visible Double Beam Spectrophotometer 11 Halo DNAmaster Microvolume Nucleic Acids And Proteins Measurement 15 Halo LED 96 Microplate Reader 20 Halo MPR 96 Visible Microplate Reader Ld Halo PlateMaster 96 Microplate Washer ZU The Velocity Range Bench Top Centrifuges NO op Velocity 14 14R Benchtop Centrifuges 2l Velocity 18R Refrigerated Benchtop Centrifuge 30 Velocity 10R Refrigerated Benchtop Centrifuge 30 Velocity 151 High Speed Microcentrifuge 36 Velocity 13u Mini Fuge oF Velocity 6p Micro Fuge 38 The C Master Range Thermal Cyclers ise ide C Master GI RT Thermal Cyclers 40 The pHMaster Range pH Meters NO pHMaster pH Meters for Routine Measurement and Life Science 43 The Aero Range Gas Chromatograph Aero A 00 Gas Chromatograph 46 lhe Halo Range Dynamica Halo UV Detective Software UV Detective is powerful user friendly software specifically designed for the control and data processing of selected Halo spectrophotometers from computers installed with the Windows XP or Windows 7 operating system The versatile UV Detective can control all spectrophotometer operations such
2. 0 005Abs with 50ul volumes Micro cuvettes ae A Suitable for use in the micro cuvette holder gt Made from quartz gt Available size 50ul Auto Sample Sipper without Temperature Control Designed for the rapid measurement of multiple or large amounts of sample without the requirement for manual washing or changing of cuvettes The sample is sipped from an external tube directly into the sipper s integrated cuvette and automatically measured The sample can also be recovered post measurement Iwo models are available with and without electronic temperature control the former maintains the flow cuvette section at a constant temperature gt Minimum sample volume 0 ml gt Wavelength range 190nm 900nm gt Carryover lt 1 gt Sipper cuvette capacity 50ul gt Optical path length 10mm Auto Sample Sipper with Temperature Control The same features as the Auto sipper with the added convenience of electronic temperature control to maintain the flow cuvette section at a constant temperature gt Temperature control range 20 C to 40 C gt Requires water circulated cooling tubing included Micro Flow Cuvette Holder Designed for the continuous measurement of trace samples The sample can be injected directly into the flow cuvette with a syringe or other injection device gt Flow cuvette capacity 0pu gt Pressure tolerance Max 0 1Mpa gt Optical path length
3. selection MikroWin2010 is the best choice for routine applications as well as extended screening curvefit and kinetic Studies Light Cylinder HALO LED 96 SPECIFICATIONS Plate Types 96 well Optical system 8 channel Transmission Photometer Light source Digital controlled LED lamps wavelength specific Photodetector 8 silicon Photodiodes Wavelength range 340 750nm special wavelengths up to 900nm Resolution 0 1 mOD 0 0001 OD Indication range 0 000 4 000 OD Abs Accuracy better than 1 and 0 005 OD up to 2 5 OD any wavelength lt 0 5 and 0 005 OD from 0 1 to 1 5 OD any wavelength Linearity lt 0 75 from 1 5 to 2 5 OD 400nm 750nm lt 0 75 and 0 005 OD from 0 1 to 2 OD 840 400 nm Reproducibility better than lt 0 3 at 10D any wavelength better than lt 0 5 at 20D 400 750nm Measurement Mode single and dual wavelength Linear scan 30 points well for agglutination etc 5 seconds kinetic interval single wavelength rerin aeea 10 seconds 96 well dual wavelength Wavelengths 4 wavelengths onboard 405 450 492 620nm up to 6 possible 340 750 Shaking 4 speeds PC Interface USB 2 0 USB 1 1 compatible Capture96 included HO cotate MikroWin2010 demo version included Dimensions 23cm x 12cm x 36cm W x H XL Weight 6 7 kg net Housing Anodized Aluminium Power Supply external power adapter 100 240V 50 or 60 Hz a
4. Dual lid electronic interlock gt Auto hinge for improved sealing and door opening gt Over speed detection and shutdown gt Motor overheat detection and shutdown User Friendly Operation Parameters are quickly and effortlessly inputted through the uncomplicated touch pad interface and displayed on the brightly backlit and easy to read LCD panel The LCD panel concurrently displays all experimentation parameters Including diagnostic information as It occurs Furthermore once centrifugation has commenced a real time graphic profile of the centrifugation status is displayed Quiet Operation Noise abating insulation in the console including lower noise fans combine to reduce the audible operating noise to lt 58 dB Liquid Seeping Prevention A single continuous rubber cap with strong gasket firmly seals the motor chamber opening and drive shaft to prevent liquid from seeping Into the motor and electronic components As additional back up a highly absorbent sponge positioned beneath the rubber cap soaks up any liquid or condensation which then evaporates during operation CAT NO MAX SPEED MAX RCF TUBE DIMENSIONS rotor material RPM XG TUBE VOLUME ML TUBE DESCRIPTION OxL MM CAPACITY ADAPTOR FA18B 18 000 24 990 1 5 2 0 Standard micro tube 10 5 x 41 19x 1 5 2 0 ri N A Aluminium o 0 5 PCR single tube 8 x 32 18 x 0 5 ml FA15 05 02 PCR single tube 6 x 24 18 x 0 2 ml FA15 02 F
5. NUMBER UV Detective Software UVDS 08 01 Windows XP Windows 7 and Microsoft Excel are trademarks of the Microsoft Corporation USA Windows and Microsoft are registered trademarks of Microsoft Corporation in the USA and other countries I NIIDITETTININJIE EPHEL i B a p ee tanh dan Ml anan EELLEEREEL I LEELERPIIENLEEEEMLEEETEN A FAELIRENEGEITI The Halo XB 10 and VIS 20 are high quality touch screen operation compact measurement systems for daily analysis in education quality control and basic research The single beam optics are compact and bench space saving The long life Xenon lamp optics system in XB 10 ensures a quick and reliable performance whereas Tungsten Halogen lamp used in VIS 20 also provides a stable measurement The intuitive color touch screen operation provides simple access to extensive range of function The touch screen Is sensitive to stylus or gloves on Icon driven on board software improves accessibility and graphical display allows spectrum or standard curve show on screen The forward and backward quick key allows user to proceed or return the process swiftly An enlarged data display for photometry measurement makes result reading easier Operation mode includes photometric multiple wavelength analysis spectrum scanning time scan kinetics and direct concentration results Varity choice of accessories included test tube holder fl
6. Ramp Rate Heating 6 C Cooling 5 C Heating 4 C Cooling 3 5 C Average Ramp Rate Heating 3 8 C Cooling 2 5 C Heating 2 3 C Cooling 1 7 C Gradient 30 99 9 C Max Range 30 C Nil Heated Lid Temperature S026 toC Memory Onboard Max 15 000 Steps Max 10 000 Steps Memory Expansion USB Flash Drive Dimensions 256 x 362 x 255mm w x d x h Weight 7 3kg Power Supply 110 220V 50 60Hz PRODUCT CATALOG NUMBER C Master GT Gradient Thermal Cycler with one 9677 Gradient Block DYNAM CMGT 9677 Gradient Block 96 x 0 2ml amp 77 x 0 5ml DYNAM CMGI 9677 96 Gradient Block 96 x 0 2m DYNAM CMGI 96 48 Gradient Block 48 x 0 2 0 5ml 108 Gradient Block 108 x 0 2ml amp 88 x 0 5m DYNAM CMGI 48 DYNAM CMG1 108 Multi Purpose Gradient Block 9677 In Situ Adaptor DYNAM CMGT MULT PC Management Software for C Master GT DYNAM CMGIT PCMS PRODUCT CATALOG NUMBER C Master RT Regular Thermal Cycler with one 9677 Non Gradient Block DYNAM CMRT 9677 Non Gradient Block 96 x 0 2m amp 77 x 0 5ml DYNAM CMRI 9677 96 Non Gradient Block 96 x 0 2ml DYNAM CMRI 96 48 Non Gradient Block 48 x 0 2 0 5ml DYNAM CMRI 48 108 Non Gradient Block 108 x 0 2m amp 88 x 0 5ml DYNAM CMRI 108 384 Non Gradient Block Multi Purpose Non Gradient Block 9677 In Situ Adaptor DYNAM CMRI 384 DYNAM CMRIT MULTI PC Management Softwar
7. V Bottom 17x 120 16x 15ml oS ISEB 4 800 4170 50 Round Bottom 29 x 104 4 x 50ml SW5 50P 4 800 3 990 50 Round Bottom 35 x 100 4 x 50ml SW5 50G 4 800 4170 50 Culture V Bottom 29x115 Ax 50ml SW5 50C SW5MP 4 800 3 120 96 Well Microplates PCR Culture 128W x 86Lx 14H 2 x Plates N A Aluminium i 96 Deep Well Plates PCR Culture 128W x 86L x 55H 2x Plates N A S20 Standard micro tube 10 8 x 40 5 48x 1 5 2 0 ml SW5MP15 0 2 PCR single or strip Um SW5MP 02 SW4A 4 000 2 900 15 Culture V Bottom 17x 120 24 x 15ml SW4A 15C 3 Aluminium 4 000 2 060 50 Culture V Bottom 29x 115 8 x 50ml SW4A 50C Without rotor lid Plastic seal caps cannot be used with these adaptors Rotor buckets are autoclavable at 121 C except Dyna NI Maximum Speed 18 000 RPM FA18A rotor Maximum RCF 27 070 x g FA18A rotor Maximum Capacity 1 000 ml 4 x 250 ml Drive Mechanism Brushless Induction Control Microprocessor based speed Range 300 18 000 RPM 100 RPM increments Speed Accuracy 20 RPM speed RCF Conversion Yes Timer 1 min 99 Hrs 59 mins plus HOLD function Display Backlit LCD Operating Noise lt 58dB A Temperature Range 20 C to 40 C Temperature Accuracy NC Memory 9 Programs Acceleration Deceleration 9 stages 9 stages Automatic Rotor Identification Yes Imbalance Detection Yes Dimensions L x D x H 730 x 610 x 380 mm Weight Net 100 Kg Power Supply single Phase AC 220V 240V 5
8. absorbance Signal is measured by an independent detector to obtain a signal reference The ratio of the values from both detectors is then calculated to detect and compensate for any aberration in the energy of the light source or a temporal change of the optical elements and produce highly stable photometric values Spectral Features Boasting a 2 nm spectral bandpass the Halo RB 10 offers Superior spectra and peak resolution Other specifications include an impressive wavelength accuracy of 0 5nm noise level 0 0005Abs 500nm and stray light lt 0 05 220nm Nal 340nm NaNO Built in and Diverse Range of Measurement Modes Photometry Mode Perform quantitative analyses in either absorbance or transmittance modes Select from single wavelength up to 6 multiple individual wavelengths nucleic acid protein A260 A280 ratios and set up calibration curves with up to 20 standards for concentration measurements Time Scan Perform kinetic measurements for time periods ranging from 1 minute to gt 27 hours Measurement intervals are factory preset and automatically selected when the scan time is set Wavelength Scan Perform a full spectral scan from 190 to 1 100nm at any of 8 incremental and preset selectable scan speeds starting from a high resolution 10nm minute up to a swift 3 600nm minute Data is displayed as either numerical values or a graphical spectrum Furthermore perform downstream processing of data such as peak valley
9. and filters HALO LED 96 is supplied with up to 6 intelligent wavelength specific LED plugins patent pending Each plugin contains its own digital ID LED light source filter and lenses in one easily exchangeable component Low Power Consumption In times like these low power consumption must be a key issue with any electrical devices With a maximum consumption of 12W during reading and a standby consumption of not more than 2W HALO LED 96 again is setting new standards Unrivaled Optical Performance Using LED s as light source moves all those known problems with halogen lamps used in other readers to history Modern LED s are known for their high and extremely stable light energy paired with very low energy consumption and no heat development Intelligent LED Plugins Adding new wavelengths e g 340nm or exchanging existing ones is as easy and safe as 1 2 3 Auto recognition of the individual plugins takes away the worry about filter positions in the reader Computer Controlled HALO LED 96 is fully computer control led Capture 96 included allows plate reading and collecting the raw OD data from the reader With its clipboard function it allows raw data to be pasted into any spreadsheet program for further calculations MikroWin2010 Compliant In combination with MikroWin2010 data reduction software optional HALO LED 96 adapts itself to any of your requirements for microplate based assays Depending on your package
10. for analysis of aromatic compounds gt Universal non destructive and high sensitivity detector Aero A700 provides standard system for some of the most common applications as well as customized solutions to fulfill your requirement Food Additive and Pesticide Residue Analysis gt Equipped with ECD to detect residual BHC DDT Pyrethrins in food gt FPD NPD is used to detect residual phosphorus containing pesticides or carbamates in food gt FID is used to analyze additive in food such as sorbic acid benzoic acid etc Solvent Residue Analysis gt Detection of residual solvent in food packaging material and drugs according to the pharmacopela gt Equipped with FID and combining headspace sampler VOC Analysis gt Equipped with FID PTV injector and a dedicated column gt Detection of benzene toluene xylenes and total volatile organic compounds Gas Analysis gt For the analysis of LPG natural gas artificial gas fermented gas etc gt With multifunction external event controller for automatic switching of different kinds of gas sampling valves Oxygenates Analysis gt Specifically designed for the analysis of gasoline fuel oil and ethanol containing diesel fuel gt Equipped with FID multiple columns with 10 port switching valve and reverse flow to detect alcohols and ethers Na 1 Temperature Ambient 5 C to 420 C increment of 1 C Temperature Accuracy 0 05 C 250 C Co
11. purity of nucleic acids can also be determined from ratio calculations such as A260 A280 nm for protein contamination of DNA preparations Furthermore The Halo DNAmaster can measure concentrations DNA RNA and oligonucloetide dye complexes The Halo DNAmaster measures protein concentrations from a range of colourimetric assays such as Bradford Lowry Biuret and BCA In addition to numerical data the standard calibration curve can be displayed Furthermore measure protein alone at 280nm or protein dye complexes that absorb at different wavelength J dsDNA Gancentral Ti 09 5 um Sample name TEST 0 3 Pmi oe F atir Lo ICE Ira POPS 131 Sample name TEST ug il The Halo DNAmaster also measures bacterial cell density at 600nm Absorbance readings of approximately 0 4units define a bacterial culture in exponential growth phase and at the most appropriate for harvest or Induction At the touch of the screen the Halo DNAmaster converts into a conventional spectrophotometer for use with either the Ultramicro cell or a standard 10mm optical path length quartz or glass cuvette It can perform single wavelength photometry in either absorbance or transmittance mode including multiple wavelength photometry for up to 6 user defined wavelengths in absorbance mode Other functions include wavelength scans time scans for kinetic studies and concentration calculations from standard CUT
12. 0 16 200 FA15B 14 000 18 990 50 Round Bottom 29 x 106 4x50 ml N A Aluminium 12 000 13 950 15 Culture V Bottom 17x120 AXIS FAIS oc 19 Round Bottom 165 ee om Fe oh FATSC 14 000 20 290 50 Round Bottom 29 x 106 6 x 50 ml N A Aluminium 12 000 14 900 i j 15 Culture V Bottom 17x120 oe ISM FAISSE 15 Round Bottom Wess excl inl FATS TSR FA10E 10 000 10 600 50 Culture V Bottom 29x115 4x50 ml N A Aluminium 10 000 10 600 i 15 Culture V Bottom 17x 120 Ax15ml FA Oot ia Round Bottom olh maA Em N A SW4C 4 000 1 780 5 Blood collection 12x 106 4x5ml Included Aluminium 4 000 1 780 Without rotor lid Dyna VELOCITY 14R 8 14 SPECIFICATIONS V14R V14 Maximum Speed 14 000 RPM FA15C rotor 14 000 RPM FA15A rotor Maximum RCF 20 290 x g FA15C rotor 18 728 x g FA15A rotor Maximum Capacity 300 ml 6 x 50 ml Drive Mechanism Brushless Induction Control Microprocessor based speed Range 300 14 000 RPM 100 RPM increments speed Accuracy 20 RPM speed RCF Conversion Yes Timer 1 min 99 Hrs 59 mins plus HOLD function Display Backlit LCD Operating Noise lt 58dB A lt 53dB A Temperature Range 20 C to 40 C Temperature Accuracy ZU Acceleration Deceleration 9 stages 9 stages Automatic Rotor Identification Yes Imbalance Detection Yes Dimensions L x D x H 560 x 500 x 380 mm 340 x 490 x 380 mm Weight Net 60 Kg 40 Kg Power Supply single Phase AC 220V 2V 50Hz 10A s
13. 0 60Hz 10A Velocity 18R Refrigerated Centrifuge 220V 50Hz V18R 2 Velocity 18R Refrigerated Centrifuge 220V 60Hz V18R 2A Velocity 18R Refrigerated Centrifuge 110V 60Hz V18R 1 Velocity TOK Refrigerated Benchtop Centrifuge The Velocity 10R takes the helm as Dynamica s highest capacity centrifuge up to 3 litres with the SW3A rotor Powerful refrigeration combined with an exceptional maximum speed of 10 000 RPM 12 740 x g with the FA10D rotor offer the versatility and convenience to manage a wide range of larger scale applications and all in a footprint sufficiently compact to fit on a bench Auto Rotor Recognition Microchip technology allows automatic rotor recognition and confirmation once centrifugation has commenced including rotational speed calculation and optimum temperature control Furthermore new rotors can be easily loaded onto the on board database as they are introduced Fast Acceleration and Deceleration The innovative heavy duty frequency conversion motor is purposely designed to handle the heaviest of rotors with abundant power output for smooth quick and efficient acceleration to terminal velocity under fully laden conditions Furthermore 9 pre set acceleration and 9 pre set deceleration profiles ensure the right conditions are met for the most precious and vibration sensitive samples Powerful Refrigeration A powerful non CFC compressor cools the chamber quickly whilst maint
14. 0 seconds Dual wavelength fast mode 96 well lt 15 seconds Plate Types 96 well with flat U or V shape bottom Optical System 8 measurement channels 1 reference channel Detector silicon Photodiodes Light Source Halogen WI Lamp Display Back lit LCD 90 W x 68 H mm Resolution 320x240 pixels shaking Linear 4 speed selectable Temperature Control optional Ambient 4 C to 50 C Temperature Accuracy optional SUDU Printer Interface Connection USB interface Printer Language Support PCL 5 or above External Storage USB flash drive Dimensions 290 W x 425 D x 200 H mm Net Weight 15Kg Gross Weight 20Kg Power Requirements 110 220 V auto switching 50 60Hz Power Consumption 50W standby 100W operation Halo MPR 96 Visible Microplate Reader 400 700nm MPR 96 Halo MPR 96 Visible Microplate Reader 400 700nm with Temperature Control Module MPR 96 TCM Ambient 5 to 50 deg C Halo MPR 96 340 Microplate Reader 340 700nm MPR 96 340 Halo MPR 96 340 TCM Microplate Reader 340 700nm with Temperature Control Module MPR 96 340 TCM Ambient 5 to 50 deg C Other wavelength filer selection from 340 to 700nm contact us for detail selections MPR IF XXX MikroWin2010 Lite Screening amp Curve Fit basic functions WR 302 03 MikroWin2010 Full Version 1 Screening amp Curve Fit extended functions WR 302 04 MikroWin2010 Full Version 2 Scre
15. 10mm gt Teflon tubing provided Duna _ Glass Sample Holder Film Sample Holder Designed for measuring the transmittance absorbance of glass samples or filters Designed for measuring the transmittance to absorbance of thin film like samples gt Glass sample thickness 0 5mm to 5mm gt Film sample dimensions gt Glass sample dimensions Min 12x25mm to 25m W 30 to 50mm H Max 55x100mm gt Beam aperture 10mm W x 20mm H HALO DB 20 DB 20S DB 20R SPECIFICATIONS Optics Concave diffraction grating Double Beam Principle Wavelength Range 190nm 1 100 nm spectral Bandwidth 1 5 nm 1 0 nm Stray Light CDe e n Mel Ur lt 0 10 220nm Nal 340nm NaNO NaNO Wavelength Accuracy 0 3nm Absorbance 3 to 3 Photometric Range 1 0 to 300 T Concentration 0 000 to 9 999 Wavelength Scan Speed 10 100 200 400 800 1 200 2 400 3 600 nm minute Baseline Stability 0 0003 Abs hr 500nm after 2 hours Noise Level 0 0003 Abs 500nm Light Source Tungsten Halogen and Deuterium Lamps Light Source Switching Automatic switching selectable from 325nm to 370nm Detector silicon Photodiode Display Back lit LCD 165 W x 122 H mm N A Dimensions 505 W x 590 D x 265 H mm Net Weight 29Kg Gross Weight 35Kg Power Requirements 110 220 V selectable 50 60Hz PRODUCT CATALOG NUMBER Halo DB 20 UV Visible Double Beam Spectroph
16. 3 Blood Collection 281 120x3ml SW4B 3B 4 000 3 S00 Blood Collection 125x106 120x5m SW4B 5B 4 000 35007 Blood Collection 125x 106 120x7ml SW4B 5B 4 000 3 450 10 Blood Collection 25 as 120x10ml SW4B 10B 4 000 3 Sill 5 Culture V Bottom xi 64x15ml SW4B 15C 4 000 3 500 50 Culture V Bottom 29x 115 20x50 ml SW4B 50CB 4 000 Sel Bid Culture V Bottom 29x 15 3250 ml ESNAB OCA Without rotor lid Dyna ce Maximum speed 10 000 RPM FA10D Maximum RCF 12 740 x g FA10D rotor Maximum capacity 3 000 ml 4 x 750ml Drive Mechanism Frequency conversion motor Control Microprocessor based speed Range 300 10 000 RPM 100 RPM increments speed Accuracy 20 RPM speed RCF conversion Yes Timer 1 min 99 Hrs 59 mins plus HOLD function Display Backlit LCD Operating Noise lt 62 dB A Temperature range 20 C to 40 C Temperature accuracy an IC Memory 9 programs Acceleration 9 stages 9 stages Automatic Rotor Identification Yes Imbalance Detection Yes Dimensions L x D x H 876 x 695 x 460 mm Weight Net 160 Kg Power requirements single phase 200v 240V 50Hz 60Hz 15A PRODUCT CATALOG NUMBER Velocity 10R Refrigerated Centrifuge 220V 50HZz V10R 2 Velocity 10R Refrigerated Centrifuge 110V 60Hz V10R 1 Velocity 15p High Speed Microcentrifuge The Velocity 15u High Speed Microcentrifuge is designed to accelerate your laboratory works by providing excellent and reliable pe
17. ATSA 15 000 215001520 Standard micro tube 10 5 x 41 24x 1 5 2 0 ml N A Aluminium i 05 PCR single tube Ba 24 x 0 5 ml FA1505 0 2 PCR single tube 6 x 24 25 x 0 2ml FA15 02 FAISE 15 000 16 600 15 20 Standard micro tube 10 5 x 41 18x 1 5 2 0 ml N A Plastic i 0 5 PCR single tube S52 18 x 0 5 ml FA15 05 0 2 PCR single tube 6 x 24 18 x 0 2ml FA15 02 FA12A 12 000 14 100 0 2 PCR single or strip 6x24 48 x 0 2 ml N A Aluminium FA18A 18 000 27 070 10 Round Bottom 16 x81 8x10ml N A Aluminium FA15B 15 000 21 800 50 Round Bottom 29 x 106 4x50 ml N A Aluminium j 15 Culture V Bottom 17 x 120 aS FA15 15C is Round Bottom oro elds 4x 15ml FA15 15R FATSC 15 000 23 300 50 Round Bottom 29 x 104 6 x 50 ml N A Aluminium i 15 Culture V Bottom 17 x 1120 eS ral FA15 15C IO Round Bottom 165x118 Ox Om FA15 15R FA15D 15 000 20 900 80 Round Bottom 38 x 106 4x80 ml N A Aluminium FA10B 10 000 11 400 50 Culture V Bottom 29x115 6x50 ml N A Aluminium n 15 Culture V Bottom 17x 120 6x15 ml FA10 15C SW5 4 800 AZ 50 Bottle le ess A x 250ml N A Aluminium 4 800 41 0 5 Blood collection 12 13 x 75 78 28 x 5ml SW5 5B Bucket 4 800 A170 37 Blood collection 12 13 x 100 28 x ml SW5 7B 4 800 Ao 10 Blood collection 16 x 100 28 x 10ml SW5 10B 3 000 1 630 10 Round Bottom 2x 105 28 x 10ml SW5 10G 3 000 1030 15 Round Bottom 17x 110 Za oil SW5 15G 4 800 4170 15 Round Bottom 16 5 x 113 16 x 15ml SUN Se 4 800 4170 15 Culture V Bottom 17 x120 12 x 15ml SW5 15CA 4 800 Arg 5 Culture
18. Auto Sample Sipper with Temperature Control The same features as the Auto sipper with the added convenience of electronic temperature control Mi to maintain the flow cuvette section ata constant gg temperature gt Temperature control range 20 C to 40 C gt Requires water circulated cooling tubing included Micro Flow Cuvette Holder Designed for the continuous measurement of trace samples The sample can be injected directly into the flow cuvette with a syringe or other injection device gt Flow cuvette capacity 0pu gt Pressure tolerance Max 0 1Mpa gt Optical path length 10mm gt Teflon tubing provided Glass Sample Holder Designed for measuring the transmittance absorbance of glass samples or filters gt Glass sample thickness 0 5mm to 5mm gt Glass sample dimensions Min 12x25mm to Max 55x100mm D ynamica Film Sample Holder Designed for measuring the transmittance absorbance of thin film like samples gt Film sample dimensions 25mm W 30 to 50mm H gt Beam aperture 10mm W x 20mm H Duna A HALO DB 30 SPECIFICATIONS Optics Diffraction grating Double Beam Wavelength Range 190nm 900nm spectral Bandwidth Selectable 0 1nm 0 2nm 0 5nm 1 0nm 2 0nm 5 0nm stray Light lt 0 010 T 220nm Nal 340nm NaNOz Wavelength Accuracy 0 3nm Wavelength Repeatability 0 1nm setting Wavelength Photometric Ac
19. Compact light weight design 880g gt Large backlit LCD for easy reading gt Intuitive and easy to use Interface gt Wide pH measurement range from 2 00 up to 20 00 pH value gt Automatic temperature compensation ATC gt Built in memory for up to 600 sets of stored data gt Electrode holder inclusive gt Acquisition software inclusive for downstream analysis of data gt Industry standard BNC connector accepts other brands of compatible pH electrodes gt Up to 3 points calibration with automatic buffer recognition function Duna _ pHMASTER LAB SPECIFICATIONS pH 2 00 to 20 00 pH Range ORP 1999 mV Temperature 10 to 110 C pH 0 01 pH Resolution ORP 0 1 full scale Temperature HB No of calibration points User selectable 1 2 or 3 points uu Automatic buffer recognition ui sm act AIC 0 to 100 C Data storage 600 groups O Koga Communication port RS 232 Power DC9V 300mA Dimensions mm 160 x 190 x 70 Weight 880 g 201 I M Plastic housing non refillable pH ATC 3 in 1 electrodes Electrode BNC connector pHMASTER BIO SPECIFICATIONS pH 2 00 to 20 00 pH Range ORP ERES Temperature 10 to 110 C pH 0 01 pH Resolution ORP 0 1 full scale Temperature 230 3 10 No of calibration points User selectable 1 2 or 3 points Ga Automatic buffer recognition on nae NA AIC 0 to 100 C Data storage 600 groups ieee Comm
20. Stability 0 001 Abs hr 500nm after 2 hours Noise Level 0 0005 Abs 500nm Light Source Tungsten Halogen and Deuterium Lamps Light Source Switching Automatic switching at 340nm Detector silicon Photodiode Display Back lit LCD 94 W x 70 H mm Dimensions 370 W x 550 D x 265 H mm Net Weight 20Kg Gross Weight 25Kg Power Requirements 110 220 V selectable 50 60Hz PRODUCT CATALOG NUMBER Halo RB 10 UV Visible Ratio Beam Spectrophotometer 110 220 V selectable 50 60Hz RB 10 220 Thermostatic Cuvette Holder with tubing RB 10 TCH Test Tube Holder includes High Ceiling Cover RB 10 TTH Micro cuvette holder RB 10 MCH Micro cuvettes quartz 50ul 10mm optical path length RB 10 MC 50 sample Sipper RB 10 SS UV Detective Software UVDS 08 01 Halo DB 20 DB 20S DB 20R UV Visible Double Beam Spectrophotometer The Halo DB 20 is a high performance double beam spectrophotometer suitable for many analytical applications that a higher level of accuracy Is required Genuine Double Beam Optics True double beam optics ensure concurrent measurement of the sample and reference for improved stability accuracy and reproducibility The light beam is split in two using a half mirror so that one beam passes through the sample side whilst the other passes through the reference side Both beams are then measured on individual detectors The reference side beam also acts to stabilize
21. VES To ensure optimum instrument performance a self diagnostic function incorporating a number of parameters is executed each time the Halo DNAmaster is switched on including a selectable GLP GMP function Validation kit is required in some parameter 4 487 Sample name TEST 0 WL SCAN KINETICS we LIME Sample mame oO HOME SYSTEM TIME STABILITY HARDWARE ADVANCED Dynamica houghtful Design Dynamica considered every detail in the design of Halo DNAmaster for example the cuvette holder can be removed for washing and it is autoclavable for decontamination Furthermore a cover protects both the cuvette holder and the detector from dust and dirt when the unit is not in use The TEE side mounted cuvette rack is detachable for easy cleaning and a smaller footprint if bench space is at a premium Ultramicro Cell The Ultramicro cell utilises fibre optic technology and is SS as in designed for measurement and analysis of extremely small volumes of DNA RNA samples with high accuracy and outstanding reproducibility In applications involving very high or very low DNA concentrations a single light path is often insufficient however the interchangeable cap of the Ultramicro cell imparts light paths of 1 mm and 0 2 mm respectively and effectively creates virtual dilutions to overcome such situations Other pathlength are available for different volume and conc
22. aining the rotor at set temperature during centrifugation Furthermore twin cooling fans one each for the compressor and motor respectively dissipate heat quickly to improve cooling efficiency and extend motor life Actual Sample Rotor Temperature Measurement and Display The temperature displayed on the LCD panel during centrifugation is that of the rotor and hence samples and neither the temperature of the chamber nor the temperature at the sensor This allows for more precise reproducible and efficient experimentation Safety is Paramount The Velocity 10R offers many safety features in the unlikely event of an emergency such as Non contact imbalance detection and shutdown based on the run profile for each rotor across its entire speed range rather than the inferior and conventional micro switch detector gt Guard barrier gt Dual lid electronic interlock gt Auto hinge for improved sealing and door opening gt Over speed detection and shutdown gt Motor overheat detection and shutdown User Friendly Operation Parameters are quickly and effortlessly inputted through the ergonomic touch pad interface and displayed on the brightly backlit and easy to read LCD panel The LCD panel concurrently displays all experimentation parameters including diagnostic information as it occurs Furthermore once centrifugation has commenced a real time graphic profile of the centrifugation status is displayed Quiet Opera
23. andalone mode User Friendly Operation and Information Rich LCD Display The extra large backlit LCD screen displays a large array of data also in graphical format The seamless and chemical resistant keypad is designed for easy and quick selection of navigation and function features Dynamica Wide Range of Detector Selection for Various Applications TCD Thermal Conductivity Detector gt Generally used analysis of inorganic gases and concentrated organic compounds gt High quality Rhenium Tungsten filament is used together with the constant flow control of dual column balance mode FID Flame Ionization Detector gt Used for analysis of volatile organic compounds gt The column flow can be measured directly thanks to the sealed main body design ECD Electron Capture Detector gt The ECD is suitable for analysis of electrophilic compounds such as chlorinated pesticide residue gt The micro flow cell design shortens stabilization time FPD Flame Photometric Detector gt The FPD is used for analysis of organic sulphur compounds and organic phosphorus compounds such as residual pesticides and malodorous components gt High quality PMT is used to ensure high sensitivity NPD Nitrogen Phosphorus Detector gt Suitable for analysis of nitrogen or phosphorus containing compounds gt Premium grade Rubidium bead is used to ensure high sensitivity and durability PID Photo lonization Detector gt Suitable
24. andpass baseline flatness baseline stability and noise level can be all validated and the audit report printed Stand Alone or PC Operation The Halo RB 10 is fully equipped and capable of executing all functions in stand alone mode Simply connect a standard laser printer for direct printouts of data and graphs For more advanced analyses and reporting the simple slide of a switch places the Halo RB 10 under the direct control of the optional UV Detective software installed on a computer with Windows XP or Windows 7 operating system 4 Sample Cuvette Holder A cuvette holder changer with a 4 cuvette Capacity is supplied as standard Therefore measurement can be expedited by inserting the 4 cuvettes in tandem and manually sliding the holder changer forwards or backwards to select the appropriate cuvette for measurement The cuvette holder changer is easily removed for cleaning purposes Rectangular Long Path Cuvette Holder Designed for low concentration or low absorbance samples gt Accommodates 4 x long path cuvettes gt Accepts cuvettes with 6 optical path lengths of 10 20 30 40 50 amp 100 mm Thermostatic Cuvette Holder Designed for applications requiring incubation and or maintenance of a sample at a constant SE temperature gt Water circulation maintains temperature stability gt Operating temperature range Room Temperature to 40 C gt Temperature stability 0 3 C gt Complete wit
25. as photometry wavelength scans time scans and more Further functions include storage of methods programs saving of numerical and graphical i data downstream data processing data transfer to commercial DON Af MY spreadsheets such as Microsoft Excel and report generation iG i 4 J 4 NE NES SE sua uma a E mi amd a mi i ei PT Pi mi mi pen m ia mi i mi i a be ee mj ai fo ee eben iT hmi __ Halo XB 10 VIS 20 RB 10 DB 20 DB 20S optional Halo DB 20R DB 30 standard Wavelength setting auto zero auto calibration optical path calibration accessories such as 6 cuvette positioner and sipper Measurement Conditions Start up setting output and storage of measurement parameters Wavelength scan time scan quantitative analysis multi spectrum measurement kinetic analysis concentration measurement nucleic acid protein measurements Data Output Display of spectra data and scans time and spectrum Multi wavelength input of constant standard curve calibration linear quadratic cubic and segment Data Processing Integral derivative flatness calculation spectrum and constant kinetic Compatible Spectrophotometers Control Functions Measurement Function Quantitative Methods Halo UV Detective Software Ordering Information PRODUCT CATALOG
26. atory spills package selection MikroWin2010 fits for routine applications as Validation Eunchaus well as extended screening curvefit and kinetic studies To ensure optimum instrument performance a self diagnostic function incorporating a number of parameters is executed each time the Halo MPR 96 is switched on Stand Alone or PC Operation The Halo MPR 96 is fully equipped and capable of executing all functions in stand alone mode Simply connect a compatible printer to the USB port for the direct printout of plate data reports and graphs please visit our website for updated list of printers For more advanced functions analyses and reporting the Halo MPR 96 can also be connected via USB ports to a PC preferred with Windows XP Pro or above operating system for direct control with the optional software On Board Storage Data The Halo MPR 96 in stand alone mode boasts on board flash memory for the storage of up to 30 test programs and up to 50 sets of plate measurement data Programs and measurement data can easily be recalled edited and deleted Furthermore plate measurement data can be readily downloaded to USB2 0 supported external memory devices for example memory sticks or external hard disks for transfer and further processing to a computer supporting commercial spreadsheets such as Microsoft Excel Temperature Control The optional peltier regulated module allows for temperature control within a rang
27. bs tele science Equipment __Sp tffophotometer e Thermal Cycler Microplate Reader Centrifuge Gas Chromatograph pH mete Dynamica Introduction Dynamica is an international company which specializes in the development production and provision of tools and services for use in life science research analytical and academic purposes We market a broad range of products include centrifuges spectrophotometers microplate readers DNA analysers and other laboratory instruments Based in Zurich Switzerland we have regional offices and manufacturing facilities in Europe Australia and Asia Together with our distribution partners in many parts of the world our professional teams support thousands of customers working in healthcare pharmaceutical chemical industrial quality assurance academic and government organizations We aim to create technological and business advantages for our customers to enable advancement in human health environmental and resource management and production efficiency From product design and research through development to production and distribution at Dynamica we always strive to deliver practical and innovative solutions with dependable services to each and every customer u KI Note Some products may not be available in certain territories Please inquire your local distributor for details h Dynamica The Halo Range UV Visible and Visible Spectrophotometers
28. by linearity of 1 up to 2 5 OD 405nm The excellent measurement uniformity across all wells is matched by an intra and inter plate variation of 0 010 OD 405nm 0 2 OD for maximum accuracy and reproducibility Other specifications include 8 measurement channels and 1 reference channel to expedite processing coupled with a swift read time of 10 seconds per 96 wells thus ensuring reliable data during kinetic analyses An optional calibration plate can also be employed to certify various regulatory compliances or validate other practices such as precision assurance Exceptional Wavelength Range The flexible filter based system allows for measurements within a spectrum range from 400nm through to a maximum of 750nm Model MPR 96UV extends the measurement to 340nm UV range Additionally the large selection of interference filters caters for the most common and critical wavelengths Up to 5 interference filters can be mounted on the carousel which Is easily accessible for effortless and quick replacement of filters if the need arises Versatile by Nature The exceptional capability of the Halo MPR 96 imparts the flexibility to perform the simplest of functions such as the generation of raw data and qualitative evaluations through to more complex functions involving kinetics and curve fits select from linear point to point quadric cubic or logistic types The Halo MPR 96 accepts 96 well microplates in flat bottom as w
29. ct printouts of data and graphs For more advanced control analyses and reporting the simple slide of a switch places the Halo DB 20 under the direct control of the optional UV Detective software installed on a computer with Windows XP or Windows 7 operating system On Board Data Storage Up to 20 operating programs and up to 10 sets of measurement data can be stored in the flash memory of the Halo DB 20 Programs can easily be recalled edited and deleted Furthermore when in stand alone mode data in text format can be downloaded directly to an external memory stick via the USB port and transferred for further processing to any computer loaded with commercial spreadsheets such as Microsoft Excel PC Control Operation DB 20R The Halo DB 20R shares the same specification of DB 20S with impressive 1nm bandwidth DB 20R is PC control only which the display and USB storage port were replaced by the UV detective software come as standard Rectangular Long Path Cuvette Holder Designed for low concentration or low absorbance samples gt Accommodates 2 x long path cuvettes sample and reference sides gt gt Accepts cuvettes with 6 optical path lengths of 10 20 30 40 50 amp 100 mm gt Outer width 12 5mm Cylindrical Long Path Cuvette Holder Designed for low concentration or low absorbance samples using a cylindrical cuvette gt Accommodates 2 x long path cylindrical cuvettes sample and refe
30. curacy NIST 930D filter 0 01nm increments 0 002Abs 0 0 5Abs 0 004Abs 0 5 1Abs 0 008Abs 1 2Abs 0 3 T Photometric Repeatability NIST 930D filter 0 001Abs 0 0 5Abs 0 002Abs 0 5 1 Abs 0 004Abs 1 2Abs 0 15 T Measurement Modes Abs T Conc E S E R Photometric Range Absorbance 4 to 5 1 0 to 600 T Conc 9 999 9 999 E S E R 0 600 Wavelength Scan Speed selectable 1 5 20 120 300 1 000 1 600 2 000 nm minute Wavelength Slew Speed 3 000nm min Baseline Flatness 0 001Abs 200 850 nm Baseline Stability 0 0004 Abs hr 500nm after 2 hours Noise Level Light Source 0 0003 Abs 500nm Tungsten Halogen and Deuterium Lamps Light Source Switching Automatic switching selectable from 325nm to 370nm Detector Photomultiplier Instrument Control PC with Windows XP or Windows 7 operating system Dimensions 710 W x 630 D x 268 H mm Net Weight 50Kg Gross Weight 56Kg Power Requirements 110 220V AC 50 60HZz 300VA Halo DB 30 UV Visible Double Beam Spectrophotometer 220V AC 50 60Hz with UV Detective Software DB 30 220 Rectangular Long Path Cuvette Holder DB 30 RLPH Cylindrical Long Path Cuvette Holder DB 30 CLPH Thermostatic Cuvette Holder includes tubing DB 30 TCH Manual 5 Cuvette Holder Changer DB 30 FCC Auto 6 Cuvette Holder Changer with te
31. e carrier gas flow can be manipulated either by constant pressure mode or constant flow rate mode Single channel or Multi channel Configurations Provide Optimal Analytical Capability Aero A700 is available with up to three channels configurations with a choice of capillary split splitless injectors and packed column injectors as well as a selection of six detectors Capillary split splitless injectors are applicable to narrow bore and wide bore capillary column The nut and seal components of the injector are gold plated to prevent chemical reaction with sample at elevated temperature Packed Column Injectors are applicable to packed column or wide bore capillary column With septum purge function interference caused by bleeding of the septum at high temperature is minimized Large Column Oven with High Precision Temperature Control System The column oven can accommodate 1 to 3 capillary columns with door open protection and overheat protection and a maximum of 10 temperature zones Fast temperature ramping of up to 80 C min is achievable by using powerful fan amp heating block system as well as the intelligent door interlock mechanism Aero Link Software amp Standalone Operation Aero Link is a powerful and user friendly software specifically designed for the control and data processing of the Aero Series gas chromatography systems Besides the Aero A 00 is fully equipped and capable of executing all functions in st
32. e for C Master RT DYNAM CMRI PCMS The pHMlaster Range Shown with optional stirrer oHlVlaster OH Meters for Routine Measurement and Life science The New pHMaster range of pH meters is designed for the contemporary laboratory environment and also specialized applications in biological and life sciences The small footprint belies advanced features augmented with a remarkable easy to use layout and all packaged In a robust casing to withstand the rigors of the laboratory All models feature a user selectable 1 2 or 3 points calibration with an automatic buffer recognition function The pHMaster BIO is designed with biological and life science applications in mind and is packaged with a combination electrode specific for TRIS buffer preparation thus overcoming the issues of inaccuracy obtained with general pH probes There is also an optional micro pH electrode with a 4 5mm diameter for small volume applications in 1 5 2ml micro tubes For general laboratory applications the pHMaster LAB is the ideal choice as it is packaged with a convenient 3 in 1 pH ATC electrode which continuously compensates for any temperature fluctuations Furthermore a variety of different electrodes is available for many applications involving environmental water food solid or semi solid samples The optional smart stirrer provides the homogeneous conditions for more accurate pH measurements Features and Characteristics gt
33. e of ambient 4 C to 50 C 0 5 C precision with excellent temperature uniformity among wells and is suitable for applications requiring incubation and or maintenance of a sample at a constant temperature for example during Kinetic analyses Other Features The microplate tray smoothly and effortlessly slides out and slides in to facilitate the loading and measurement of microplates The durable motor ensures consistent and long lasting operation The microplate tray can be operated in both stand alone and PC control modes The halogen lamp features long life stability and can also be easily accessed and changed within minutes Duna _ HALO MPR 96 SPECIFICATIONS Wavelength Range 400nm 750nm 340 750nm for MPR 96 UV Photometric Range Absorbance 0 to 4 0 OD Resolution 0 001 OD stability 0 001 OD 15 minutes after start up Better than 1 0 0 01 OD 405nm 0 000 2 500 OD Accuracy Better than 2 0 0 01 OD 405nm 2 500 3 000 OD Repeatability Better than 0 5 0 005 OD 405nm 0 000 2 500 OD Better than 1 5 0 005 OD 405nm 2 500 3 000 OD Linearity Better than 1 0 405nm 0 000 2 500 OD Better than 2 0 405nm 2 500 3 000 OD Filter Capacity 5 position 4 standard 405nm 450nm 492nm 620nm 1 optional between 400nm to 750nm UV model with 340nm as standard Reading Speed single wavelength fast mode 96 well lt 1
34. ed through the uncomplicated touch pad interface and displayed on the brightly backlit and easy to read LCD panel The LCD panel concurrently displays all experimentation parameters including diagnostic information as it occurs Duna _ Furthermore once centrifugation has commenced a real time graphic profile of the centrifugation status is displayed Quiet Operation Noise abating Insulation in the console including lower noise fans combine to reduce the audible operating noise to lt 53 dB lt 58 dB for V14R CAT NO rotor V14R V14 MAX SPEED RPM V14R V14 MAX RCF XG Liquid Seeping Prevention A single continuous rubber cap with strong gasket firmly seals the motor chamber opening and drive shaft to prevent liquid from seeping Into the motor and electronic components As additional back up a highly absorbent sponge positioned beneath the rubber cap soaks up any liquid or condensation which then evaporates during operation TUBE TUBE VOLUME DIMENSIONS CAPACITY ML ADAPTOR TUBE DESCRIPTION ELC ELD xL MM FATSA 14 000 18 728 70 Standard Oa 24 x 1 5 2 0 ml N A Aluminium 14 000 18 728 micro tube i i Us PCR single tube 8x32 2A XOS m FA15A 05 0 2 PCR single tube 6x24 25 X0 Zm FA15A 02 FA12A 12 000 12290 0 2 PCR single or strip 6 x 24 48 x 0 2 ml N A Aluminium 12 000 12 290 FATSA 14 000 16 200 10 Round Bottom 16 x 81 8x 10 ml N A Aluminium 14 00
35. ell as U and V shaped configurations The unit can also be automated for high throughput by integrating compatible robotic handling systems Diverse Range of Measurement Modes Select from Fast mode when quick measurement is required for example screening applications to Accurate mode when high resolution is necessary Other modes include gt Centre Measurement to detect small samples with a non linear surface gt Single or dual wavelengths gt Plate shaking 4 speeds linear motion before measurement or in between cycles for example during kinetic analyses User Friendly Operation and Information Rich LCD Display The 90mm x 68mm backlit LCD screen with adjustable brightness control is sufficiently large to display a comprehensive array of data even in a graphical format for example up to 48 wells i e half of a 96 well plate can be displayed concurrently with the added capability to zoom in on specific data points Other displayed parameters in addition to measurement results include operation prompts plate layout and historical data D unan Ica The seamless and chemical resistant keypad is designed for easy MikroWin2010 Compliant and quick selection of the navigation and function features when MPR 96 extends the data analysis function to computer with the in stand alone mode whilst simultaneously protecting against optional MikroWin2010 data reduction software With different any labor
36. emperature between 20 C to 40 C gt Includes magnetic stirrer and fleas gt Requires water circulated cooling tubing included 6 Cuvette Holder Changer without Electronic Temperature Control Designed for mounting up to 6 standard 10mm cuvettes without temperature control and stirring gt Total capacity 6 cuvettes on sample beam side 1 cuvette on reference side gt Electronic change over change cuvettes automatically at defined time intervals Micro cuvette Holder Designed for measuring micro volumes with 5Oul micro cuvette gt Wavelength range 220 to 880nm gt Noise level 0 001Abs with 50u volumes Micro cuvettes Suitable for use in the micro cuvette holder gt Made from quartz gt Available size 50ul Auto Sample Sipper without Temperature Control Designed for the rapid measurement of multiple Or large amounts of sample without the requirement for manual washing or changing of cuvettes The sample is sipped from an external tube directly into the sipper s integrated cuvette and automatically measured The sample can also be recovered post measurement Two models are available with and without electronic temperature control the former maintains the flow cuvette section at a constant temperature gt Minimum sample volume 0 ml gt Wavelength range 190nm 900nm gt Carryover lt 1 gt Sipper cuvette capacity 50ul gt Optical path length 10mm
37. ening amp Curve Fit amp Kinetic extended functions WR 302 05 For more information on MikroWin2010 and it s features please visit www mikrotek de Halo PlateMaster 96 Microplate Washer The Halo PlateMaster 96 microplate washer provides an Operation It is also compatible with flat U or V bottom 96 well automated and flexible process control strip washing for microplates for different applications microplates Reliable Performance Flexible Process For great value Platemaster 96 will be your best choice It is Platemaster 96 allows selection from manifolds of 8 or 12 equipped with a 3 speed shaking action to minimize bubbles channels 4 liquid channels 3 washing methods including generated and adherence of liquid to well sides The waste normal aspiration overflow and bottom washing Working on water sensor for high waste level detection gives you additional different assays is easy with the independent liquid channels reliability A dispensing precision of better than 2 CV and without frequent bottle changes The large LCD display with on residual volume lt 2 ul are proven with the advanced wash head board control allows up to 40 wash programme storage for easy design HALO PLATEMASTER 96 SPECIFICATIONS Plate manifold format 96 well plate with 8 or 12 channel manifold Wash programs Up to 40 Dispense volume Wash liquid volume adjustable from 50 ul to 3000 ul in 50 ul increments Dispense preci
38. entration limit A further function of the cap is to prevent the sample from drying up and to ensure that measurements remain reproducible since sample characteristics can be affected by evaporation of the solvent Programmable Temperature Control Model The DNAmaster temperature control model utilizes a peltier regulated cell holder to control the sample temperature from a range of 20 C to 95 C with 0 5 C precision O o _ Q S Predominantly designed for the determination of nucleic acid Tm at 260nm up to 4 heating profiles can be selected including 1 C min 2 C min or a quick heat mode for heating Time mins up to a plateau temperature of 50 C at 5 C min before ramping commences at 1 C min or 2 C min The heated cell holder can also be used in other applications requiring incubation and or keeping a sample at a constant temperature for example during Kinetic analyses Dyna Lamp Source Long Life Xenon Flash Lamp Detector Device 2048 pixel CCD Wavelength Range 200 900nm Measuring Range 0 4 0 OD Wavelength Accuracy 1nm Bandwidth 4nm Noise 0 005 OD RMS Drift 0 005 OD Photometric Accuracy 0 01 OD Photometric Repeatability 0 005 OD Stray Light 0 5 T 13ng ul Standard cap Ultramicro Cell dsDNA Detection Limit Depends on the Cap Used 6ng ul Optional cap Ultramicro Cell Minimum Sample Volu
39. es and reference sides gt Accepts cuvettes with 6 optical path lengths of 10 20 30 40 50 amp 100 mm amp gt External water circulation maintains temperature stability Cylindrical Long Path Cuvette Holder Designed for low concentration or low absorbance samples using a cylindrical cuvette gt Accommodates 2 x long path cylindrical cuvettes sample and reference sides Thermostatic Cuvette Holder Designed for applications requiring incubation and or maintenance of a sample at a constant temperature gt Operating temperature range Room Temperature to 40 C gt Temperature stability 0 3 C gt Complete with tubing for quick connection to water source such as circulating water bath a i 5 Cuvette Holder Changer Designed for mounting up to 5 standard 10mm cuvettes on the sample beam side gt Total capacity 5 cuvettes on sample beam side 1 cuvette on reference beam side gt Turret design cuvette holder for efficient changeover gt Manual change of cuvettes by turning front mounted knob no temperature control 6 Cuvette Holder Changer with Electronic Temperature Control Designed for mounting up to 6 standard 10mm cuvettes with temperature control and stirring gt Total capacity 6 cuvettes on sample beam side 1 cuvette on reference side gt Electronic change over change cuvettes automatically at defined time intervals gt Electronic thermostat set t
40. h tubing for quick connection to water source such as circulating water bath Test Tube Holder Designed for the direct measurement of samples in a test tube with no need to transfer to a cuvette gt Spring mechanism automatically adjusts and accepts test tubes with diameters from 12 18 mm gt High ceiling cover accommodates even the tallest test tubes Duna Micro cuvette Holder Designed for measuring micro volumes with 50ul micro cuvette gt Wavelength range 220 to 950nm gt Noise level 0 004Abs with 50u volumes Micro cuvettes Suitable for use in the micro cuvette holder gt Made from quartz gt Available size 50u Sample Sipper Designed for the rapid measurement of multiple samples Sample is sipped from an external tube directly into the sipper s integrated cuvette and automatically measured The sample can also be recovered post measurement gt Minimum sample volume 0 6m gt Carryover lt 1 gt Sipper cuvette capacity 50ul gt Optical path length 10mm HALO RB 10 SPECIFICATIONS Optics Concave diffraction grating Ratio beam Principle Wavelength Range 190nm 1 100 nm spectral Bandwidth 2nm Stray Light lt 0 05 220nm Nal 340nm NaNO Wavelength Accuracy 0 5nm Absorbance 3 to 3 T 0 to 300 Concentration 0 000 to 9 999 Photometric Range Wavelength Scan Speed 10 100 200 400 800 1 200 2 400 3 600 nm minute Baseline
41. ides gt Lid heating will automatically turn off if block temperature is excellent thermal accuracy and uniformity of 0 2 C for non lower than 30 C gradient protocols and 0 3 C for gradient protocols C Master is gt Easy storage and transfer protocols among cyclers using a also capable to produce high temperature ramp rates to shorten USB storage device the time to reach target temperature gt Capable to control 100 thermal cyclers with optional PC User Friendly Operation Management Software The 7 inch color touch screen interface allows you to quickly manage your programs and start the runs with ease The interface with intuitive software features color graphic easy program folder editing personalized password protection and on board storage capacity of more than 10 000 programs Efficient Optimization Feature of C Master GT Gradient Thermal Cycler C Master GT allows you to optimize your protocol in a single run by testing 12 different incubation temperatures simultaneously across a wide range of 30 C Together with the latest Peltier technology the gradient calculator controls and ensures high accuracy and uniformity of each column C MASTER GT C MASTER GT amp RT SPECIFICATION GRADIENT THERMAL CYCLER Block Temperature OFC to 100 C Duna vf C MASTER RT REGULAR THERMAL CYCLER Block Uniformity lt 0 2 C at 95 C Temperature Accuracy lt 0 2 C at 35 C to 100 C Max
42. ing and mounting including a flexible drive shaft allow for greater imbalance tolerances so that samples can be balanced simply with the naked eye No more weighing just fill tubes or bottles to within 5mm of each other Powerful Refrigeration Velocity 14R model only A powerful non CFC compressor cools the chamber quickly whilst maintaining the rotor at set temperature during centrifugation Furthermore twin cooling fans one each for the compressor and motor respectively dissipate heat quickly to improve cooling efficiency and extend motor life Actual Sample Rotor Temperature Measurement and Display Velocity 14R only The temperature displayed on the LCD panel during centrifugation is that of the rotor and hence samples and not the temperature of the chamber nor the temperature at the sensor to allow for more precise reproducible and efficient experimentation Safety is Paramount The Velocity 14 14R offers many safety features in the unlikely event of an emergency such as Non contact imbalance detection and shutdown based on the run profile for each rotor across its entire speed range rather than the inferior and conventional micro switch detector gt Guard barrier gt Dual lid electronic interlock gt Auto hinge for improved sealing and door opening gt Over speed detection and shutdown gt Motor overheat detection and shutdown User Friendly Operation Parameters are quickly and effortlessly inputt
43. ingle Phase AC 220V 2V 50Hz 8A PRODUCT CATALOG NUMBER Velocity 14R Refrigerated Centrifuge 220V 50Hz V14R 2 Velocity 14R Refrigerated Centrifuge 220V 60HZz V14R 2A Velocity 14R Refrigerated Centrifuge 110V 60Hz V14R 1 Velocity 14 Centrifuge 220V 50 60Hz V14 2 Velocity 14 Centrifuge 110V 60Hz V14 1 Velocity 18R Refrigerated Benchtop Centrifuge The Velocity 18R delivers high capacity refrigerated centrifugation with an impressive maximum speed of 18 000 RPM 27 070 x g with the fixed angle FA18 rotor and all from the convenience of the bench Quick Set and Forget Rotor System screwing or bolting rotors to the drive shaft is a thing of the past Likewise lost spanners and rotor over tightening With the Velocity 18R simply place the rotor on the drive shaft and that s all The auto lock and secure mechanism performs the rest Once centrifugation is complete simply lift the rotor off the drive shaft Quicker easier more efficient and safer Auto Rotor Recognition Automatic rotor recognition and confirmation once centrifugation has commenced including rotational speed calculation and optimum temperature control Furthermore new rotors can be easily loaded onto the on board database as they are Introduced Fast Acceleration and Deceleration The innovative high torque drive technology effortlessly accelerates even the heaviest rotors to terminal velocity quickly and efficie
44. instrument Refer to page 3 for further details on the UV Detective software UV Detective can also operate optional accessories such as the sample sipper and 6 cuvette holder The UV Detective software is powerful but user friendly using Windows XP or Windows 7 as depicted in the process flow below gt Select Function e g Photometry gt Set Method Parameters gt Auto zero or Baseline gt Sample test gt Data processing gt Report Generation Dual Lamp Advantage By virtue of the long life halogen tungsten and deuterium lamps the Halo DB 30s wavelength range extends from 190nm 900nm Furthermore the dual lamp system results in higher accuracy than corresponding xenon lamps Lamp switching is automatic and selectable from a wavelength range of 325nm to 3 0nm Validation Functions To ensure optimum instrument performance self diagnosis incorporating a number of parameters and wavelength calibration are automatically initiated upon start up Furthermore the Halo DB 30 and the UV Detective software Is equipped with a GLP GMP feature for analyses requiring validation and auditing Parameters such as wavelength accuracy wavelength reproducibility bandpass baseline flatness baseline stability and noise level can be all validated and the audit report printed Duna Rectangular Long Path Cuvette Holder Designed for low concentration or low gt Accommodates 2 x long path cuvettes sample absorbance sampl
45. k and calendar sur self Diagnosis PRODUCT CATALOG NUMBER Halo XB 10 UV Visible Single Beam Spectrophotometer 100 230V 50 60Hz XB 10 Halo VIS 20 Visible Single Beam Spectrophotometer 100 230V 50 60Hz VIS 20 Test Tube Holder XB 10 TTH Micro cell holder XB 10 MCH sample Sipper XB 10 SS Temperature Control Holder 20 40 C XB 10 TCH Rectangular Long Pathlength Cuvette Holder XB 10 RLPH Manual 5 Cell Changer XB 10 M5C Automatic 5 Cell Changer XB 10 A5C VIS 10 economy choice for routine test purpose is also available Halo RB 10 UV Visible Ratio Beam spectrophotometer The Halo RB 10 is a ratio beam spectrophotometer with an extensive array of built in functions for versatility and suitability to many analytical and biological applications The ratio beam Optics impart greater accuracy and reproducibility than the conventional single beam optics Ratio Beam Optics The absorbance signal in conventional single beam instruments can destabilize and resulting in data inaccuracy By contrast ratio beam optics compensate and stabilize signal fluctuations to increase accuracy and reliability even over prolonged usage such as in time course and kinetic measurements The ratio beam principle involves splitting the beam generated by the light source by a half mirror One of the split beams passes through the sample and is quantified by a detector whereas the other split beam which is representative of the
46. l life science education manufacturing and many others Exceptionally Low Stray Light The intricate but elegant and innovative optical pathway is engineered to deliver outstanding double beam performance characteristics in particular stray light which achieves an impressive low 0 010 1 The outcome is an increase in the linearity of absorbance characteristics for most samples thus increasing the scope of analytical applications particularly at higher concentrations Spectral Features The asymmetric monochromator with long focal length results in improved sensitivity Furthermore up to 6 slit widths are selectable and switchable with the highest achievable resolution of 0 1 nm thus allowing for the optimization of different applications Other specifications include an impressive wavelength accuracy of 0 3nm noise level 0 0003Abs 500nm wavelength repeatability of 0 1nm for the accuracy and reproducibility of analytical data and an absorbance range of 4 to 5 Abs for the analysis of high absorbance samples without the need for further dilution High Scan Speeds and Resolution select from 8 scan speeds starting at a high resolving 1nm min Coupled with the precise fine tuning of the photomultiplier tubes a wavelength resolution of 0 1nm is maintained even at the fastest scan speed of 2 000 nm min Powerful UV Detective PC Control The Halo DB 30 is PC controlled using the UV Detective software included with the
47. lumn Oven Temperature Ramp 0 1 to 80 C min max 22 ramp Capacity 16L Temperature Ambient 5 C to 420 C Injection Ports Up to 3 Ports sample Injection Heating Zone 5 Flow Control Mode Automatic Flow Pressure Control Pressure 0 to 40 psi Temperature Ambient 5 C to 420 C Detector No of Detectors Up to 3 Detectors Dimensions wx d xh ol oe lO a0 mm GC Main Unit Weight 55Kg Power Requirements AC 220 240V 50Hz Detection Limit lt 5 x 101 g s n hexadecane Detection Limit N lt 5 x 10 2g s Azobenzene Baseline Noise Zox A P lt 5x 1013g s Malathion Baseline Drift lon ay Simin Baseline Noise e CRN Baseline Drift lt 4x 10 A 30min TCD FPD Sensitivity 10 000mV ml mg n hexadecane Detection Limit S lt 8 x 10 g s Parathion methyl Baseline Noise lt 30uV 99 999 H gas P lt 8 x 1013g s Parathion methyl Baseline Drift lt 100uV 30min Baseline Noise zox IOWA Baseline Drift lt 5 x 10 2A 30min Sensitivity lt 3 x 10 g ml y BHC Detection Limit S lt 5 x 10 2g s benzene Baseline Noise 15uV Baseline Noise 5x10 A Baseline Drift 100uV 30min Baseline Drift 3 20 Sey shi Radiation Source Ni 10mCi Dynamica Headquarters Dynamica GmbH Moosmattstr 32 CH 8953 Dietikon Switzerland P 41 44 744 2828 F 41 44 744 2838 Email info dynamica eu com Australasia Dynamica Pty Ltd Unit C3 Hallmarc Business Park Corner Centre and Westall R
48. me 0 7ul Standard cap Depends on the Cap Used 0 5ul Optional cap Start Up Melodies Selectable from 7 types and mute Energy Saving Mode Yes Memory Storage Internal or SD card 40 000 internal peu eave Unlimited SD Card User Defined Program Storage 10 for each function 300x 300X115 AGACIN ACD a r 300 x 300 x 155 TC model 3 5kg ae 4 5kg TC mode Power Requirement 110 220 V 50 60Hz Factor 2mm cap 1 mm cap 0 2 mm cap 0 1 mm cap Total Detection Range dsDNA ng ul 50 6 425 13 850 63 4250 125 8500 6 8500 Required Sample Volume 6 10 ul 3 5 ul 0 7 to4ul 0 5 to 3 ul Halo DNAmaster 200nm 900nm with 50ul microvolume cell DNAM Halo DNAmaster 200nm 900nm with ultramicro cell 0 2mm amp 1mm cap included DNAM UM Halo DNAmaster 200nm 900nm temperature control model DNAM TC Compact thermal printer for DNAmaster DNAM PRINT Ultramicrocell with 1mm and 0 2mm cap ULTRACELL 2mm cap for DNAmaster ultramicro cell 2MM CAP 1mm cap for DNAmaster ultramicro cell 1MM CAP 0 2mm cap for DNAmaster ultramicro cell 0 2MM CAP 0 1mm cap for DNAmaster ultramicro cell 0 1MM CAP Halo LED 96 Microplate Reader HALO LED 96 is a computer controlled microplate reader for 96 well plates Easy and safe operation removes the hassle from your daily microplate reading jobs It is based on the most modern LED technology no need to worry about lamp replacements anymore LED Technology Instead of lamps
49. mperature control and stirrer DB 30 SCCT Auto 6 Cuvette Holder Changer without temperature control and stirrer DB 30 SCC Micro cuvette Holder DB 30 MCH Micro cuvette quartz 50ul 10mm optical path length MC 50 Auto Sample Sipper with temperature control DB 30 SST Auto Sample Sipper without temperature control DB 30 SS Micro Flow Cuvette Holder DB 30 MFH Glass Sample Holder DB 30 GSH Film Sample Holder DB 30 FSH Microvolume Nucleic Acids And Proteins Measurement The Halo DNAmaster complements the existing range of Halo spectrophotometers and plate readers It is designed for the measurement and analysis of precious samples by requiring only microvolume quantities Naturally DNAmaster features the same ruggedness reliability precision and reproducibility synonymous with the Halo family The Halo DNAmaster is equipped with a comprehensive selection of on board functions for versatility and suitability to many life science applications involving nucleic acid proteins and bacterial cultures The Halo DNAmaster boasts a wavelength range from 200 to 900nm an absorbance range between 0 4 0 D and a wavelength accuracy of 1nm Low noise 0 005 0 D combined with a photometric accuracy of 0 01 0 D and 4nm bandwidth ensure excellent sensitivity accuracy and reproducibility By virtue of the innovative Ultramicro cell as little as 0 5 of sample is required optional cap is needed Simply pipette the sample on the a
50. ntly Even the heaviest rotors with a full load will achieve maximum velocity within a few minutes Furthermore 9 pre set acceleration and 9 pre set deceleration profiles ensure the best separation even for the most delicate density gradients High Imbalance Tolerances Innovative motor engineering and mounting including a flexible drive shaft allow for greater imbalance tolerances so that samples can be balanced simply with the naked eye No more weighing just fill tubes or bottles to within 5mm of each other Powerful Refrigeration A powerful non CFC compressor cools the chamber quickly whilst maintaining the rotor at set temperature during centrifugation Furthermore twin cooling fans one each for the compressor and motor respectively dissipate heat quickly to improve cooling efficiency and extend motor life Actual Sample Rotor Temperature Measurement and Display The temperature displayed on the LCD panel during centrifugation is that of the rotor and hence samples and not the temperature of the chamber nor the temperature at the sensor to allow for more precise reproducible and efficient experimentation Safety is Paramount The Velocity 18R offers many safety features in the unlikely event of an emergency such as Non contact imbalance detection and shutdown based on the run profile for each rotor across its entire speed range rather than the inferior and conventional micro switch detector gt Guard barrier gt
51. oads Clayton Victoria 3168 Australia P 61 3 8540 5988 F 61 3 9548 7177 Email info dynamica com au Asia Dynamica Asia Limited Room 607 Yen Sheng Centre 64 Hoi Yuen Road Kwun Tong Kowloon Hong Kong P 852 3583 1581 F 852 3583 1580 Email info dynamica asia com Web www dynamica eu com 10 2012
52. otometer 110 220 V selectable 50 60Hz DB 20 220 Halo DB 20S UV Visible Double Beam Spectrophotometer 110 220 V selectable 50 60Hz DB 20S 220 Halo DB 20R UV Visible Double Beam Spectrophotometer 110 220 V selectable 50 60Hz DB 20R 220 Rectangular Long Path Cuvette Holder DB 20 RLPH Cylindrical Long Path Cuvette Holder DB 20 CLPH Thermostatic Cuvette Holder includes tubing DB 20 TCH Manual 5 Cuvette Holder Changer DB 20 FCC Auto 6 Cuvette Holder Changer with temperature control and stirrer DB 20 SCCT Auto 6 Cuvette Holder Changer without temperature control and stirrer DB 20 SCC Micro cuvette Holder DB 20 MCH Micro cuvette quartz 50u 10mm optical path length MC 50 Auto Sample Sipper with temperature control DB 20 SST Auto Sample Sipper without temperature control DB 20 SS Micro Flow Cuvette Holder DB 20 MFH Glass Sample Holder DB 20 GSH Film Sample Holder DB 20 FSH UV Detective Software UVDS 08 01 Note Not Applicable for Halo DB 20S amp DB 20R Halo DB 30 UV Visible Double Beam Spectrophotometer The next generation Halo DB 30 double beam spectrophotometer boasts superlative performance characteristics for applications demanding the utmost sensitivity by combining higher signal to noise ratios with minimal stray light This warrants the Halo DB 30 suitable to many diverse fields and industries such as pharmaceutical food sanitation environment biology agriculture geology mineral petrochemical optica
53. ow cell with sipper temperature control holder long pathlength cuvette holder multiple cell holder are available to enhance different application needs External storage with SD card allows data export to PC compatible text or spreadsheet format Method and result storage is almost unlimited by exchanging SD card when needed Printer options are available for direct result printing with graphics For advanced control analyses and reporting can be performed by the optional UV Detective software installed on a computer To ensure optimum instrument performance self diagnosis functions are equipped in GLP GMP wizard for performance validation and auditing HANACEP SETTING TIME SPAN Conr HENASEF SETTING HALO XB 10 VIS 20 SPECIFICATIONS BAD is Wavelength Range 190 to 1000nm 330 to 1000nm Resolution nm Spectral Bandwidth onm 8nm Transmittance accuracy a oul Transmittance repeatability 0 50 Noise 0 004A at OA at 250nm stray light lt 0 5 at 220nm 340nm 360nm Wavelength accuracy 2nm Wavelength repeatability nm Absorbance 0 3 to 1 999 Transmittance 0 to 199 9 Spectrum Scanning Yes Concentration 300 to 1999 selectable Resolution 1 0 1 0 01 or 0 001 Memory SD card storage Quantitation 300 to 1999 Time Scan Display Graphical and calculated concentration value Wavelength scan analysis Absorbance and wavelength of peaks and valleys Cloc
54. photometric values in a similar manner to the ratio beam principle Spectral Features Coma aberration elimination from the concave diffraction grating achieves a high resolution 1 5 nm DB 20S 1nm spectral bandpass and certifies compliance of the Halo DB 20 to the stringent European Pharmacopoeia standards Other specifications include an impressive wavelength accuracy of 0 3nm noise level 0 0003Abs 500nm and stray light lt 0 05 220nm Nal 340nm NaN02 Built in and Diverse Range of Measurement Modes Photometry Mode Perform quantitative analyses in either absorbance or transmittance modes Select from single wavelength up to 6 different individual wavelengths nucleic acid protein A260 A280 ratios and set up calibration curves with up to 20 standards for concentration measurements Time Scan Perform kinetic measurements for time periods ranging from 1 minute to gt 27 hours Measurement intervals are factory preset and automatically selected when the scan time is set Wavelength scan Perform a full spectral scan from 190 to 1 100nm at any of 8 incremental and preset selectable scan speeds starting from a high resolution 10nm minute up to a swift 3 600nm minute Data is displayed as either numerical values or a graphical spectrum Furthermore perform downstream processing of data such as peak valley search or smoothing directly on board or with the optional Halo UV Detective software Dual Lamp Advantage By vir
55. ppropriate section of the Ultramicro cell perform the measurement and then wipe off or aspirate the sample for further downstream applications The Halo DNAmaster can also be used as a conventional spectrophotometer with standard 10mm optical path length cuvettes If microvolume measurement is not a must the Halo DNAmaster is also available configured with 50ul cells However both configurations can also be used as a conventional spectrophotometer with standard 10mm optical path length cuvettes The 90mm x 120 mm colour LCD screen is touch sensitive with intuitively designed software for quick selection by sample type Effortless step by step navigation and a virtual QWERTY keyboard provide fast and efficient input and analysis Data is displayed numerically and also in a graphical format where applicable with the further option of direct printing or storage in a SD card Master Report PC software is available for convert the settings and results in a report format Microsoft Excel is required The Halo DNAmaster is configured with onboard functions for the quantification of nucleic acids Select the nucleic acid of choice such as double stranded DNA single stranded DNA RNA or oligonucleotides and absorbance measurements at the prescribed wavelength are directly converted into concentration units The detection limit of the Halo DNAmaster is 6ng ul double stranded DNA with optional 2mm cap of ultramicro cell The
56. r up to 6 x 50 ml tubes reaching an impressive terminal velocity of 14 000 RPM 20 290 x g in V14R The new SWA4C Swing Bucket Rotor further expands the flexibility of the Velocity 14 14R centrifuges to incorporate a wide range of new applications Quick Set and Forget Rotor System screwing or bolting rotors to the drive shaft is a thing of the past Likewise lost spanners and rotor over tightening With the Velocity 14 14R simply place the rotor on the drive shaft and that s all The auto lock and secure mechanism performs the rest Once centrifugation is complete simply lift the rotor off the drive shaft Quicker easier more efficient and safer Auto Rotor Recognition Microchip technology allows automatic recognition of rotor and confirmation once centrifugation has commenced including rotational speed calculation and optimum temperature control Furthermore new rotors can be easily loaded onto the on board database as they are Introduced Fast Acceleration and Deceleration The innovative high torque drive technology effortlessly accelerates even the heaviest rotors to terminal velocity quickly and efficiently Even the heaviest rotors with a full load will achieve maximum velocity within a few minutes Furthermore 9 pre set acceleration and 9 pre set deceleration profiles ensure the right conditions are set for the most precious samples including density gradients High Imbalance Tolerances Innovative motor engineer
57. rence sides Thermostatic Cuvette Holder Designed for applications requiring incubation ran and or maintenance of a sample at a constant Th temperature 4 gt External water circulation maintains temperature stability gt Operating temperature range Room Temperature to 40 C gt Temperature stability 0 3 C gt Complete with tubing for quick connection to water source such as circulating water bath a gt Turret design cuvette holder for efficient changeover 5 Cuvette Holder Changer Designed for mounting up to 5 standard 10mm cuvettes on the sample beam side gt Total capacity 5 cuvettes on sample beam side 1 cuvette on reference beam side gt Manual change of cuvettes by turning front mounted knob gt No temperature control 6 Cuvette Holder Changer with Electronic Temperature Control Designed for mounting up to 6 standard 10mm cuvettes with temperature control and P stirring gt Total capacity 6 cuvettes on sample beam side 1 cuvette on reference side gt Electronic change over change cuvettes automatically at defined time intervals gt Electronic thermostat set temperature between 20 C to 40 C gt Includes magnetic stirrer and fleas gt Requires water circulated cooling tubing included Duna Micro cuvette Holder Designed for measuring micro volumes with 5Oul micro cuvette gt Wavelength range 220 to 950nm gt Noise level
58. rformance The Velocity 15u is compact and easy to use Features amp Characteristics gt Maximum speed 15 000rpm 21 380 xg gt Choices of rotors for 24 x 0 2 0 5 1 5 2 0ml tubes 18 x 5ml tubes 36 x 0 5ml tubes and 4x 8 strip PCR tubes gt Autoclavable Bio satfe rotors gt Advanced air cooling technology to lower rotor temperature gt Automatic lid release after run gt Dual door interlock safety design gt User friendly control panel with large LCD display FAS15B Maximum Speed 15 000 RPM Maximum RCF UJOUX U Run Time 30 Seconds to 99 Minutes or HOLD Continuous Rotor Standard 24 x 1 5 2 0 ml tubes Rotor Optional 18 x 5 ml tubes 36 x 0 5 ml tubes 4 x 0 2ml 8 strip PCR tubes Dimensions 280 x 364 x 266 mm wx d xh Weight 12 kg Power Supply AC 200 240V 50 60Hz or AC 110 120V 50 60Hz Velocity 15u High Speed Microcentrifuge with FAS15B aluminum alloy rotor kit 200 240V 50 60Hz V15U 220 Velocity 15u High Speed Microcentrifuge with FAS15B aluminum alloy rotor kit 110 120V 50 60Hz V15U 110 18 place rotor with lid 5ml x 18 15000rpm FAS15A 24 place rotor with lid 1 5 2ml x 24 15000rpm FAS15B 36 place rotor with lid 0 5m x 36 15000rpm FAS15C 4 place 8 strip PCR tubes rotor with lid 15000rpm FAS15D 0 2ml rotor adapter used with FAS15B 24 place rotor 24pcs pk FAS15B 02 0 5ml rotor adapter used with FAS15B 24 place rotor 24pcs pk FAS15B 05 0 2ml rotor adapter
59. search or smoothing directly on board or with the optional Halo UV Detective software Dual Lamp Advantage By virtue of the halogen tungsten and deuterium lamps typically found in higher end analytical spectrophotometers the Halo RB 10 wavelength range is an impressive 190nm 1 100nm Furthermore a dual lamp system results in higher accuracy than corresponding xenon lamps Lamp switching is automatic by default at 340nm and both lamps are long life User Friendly Operation and Information Rich LCD Display The 94mm x 70mm backlit LCD screen with adjustable brightness control is sufficiently large to display a large array of data even in a graphical format Furthermore single wavelength absorbance or transmittance data can be enhanced and enlarged using the unique zoom function The seamless and chemical resistant keypad is designed for easy and quick selection of navigation and function features whilst protecting against any laboratory spills Other unique features include the GO TO WL short cut key to allow direct input of a new wavelength into an existing measurement Validation Functions To ensure optimum instrument performance a self diagnostic function incorporating a number of parameters is executed each time the Halo RB 10 is switched on Furthermore the Halo RB 10 is equipped with a GLP GMP feature for analyses requiring validation and auditing Parameters such as wavelength accuracy wavelength reproducibility b
60. sion lt 2 CV Residual volume lt 2 ul per well soak time Up to 990 s with 10s increment Wash liquid channels 2 1x wash buffer 1x rinse liquid standard Up to 4 wash liquid option shaking speed 3 types Dimensions W x D x Hicm 48 x 35 x 20 Net Weight kg 11 shipping weight kg o Power supply 100 240 VAC Halo PlateMaster 96 Microplate Washer 100 240V 50 60Hz PM 96 The Velocity Range Velocity 14 14 Benchtop Centrifuges The Velocity 14 14R centrifuges set a new benchmark in versatility and compactness The clever design results in a compact footprint yet generous capacity which not only frees up precious bench space but also provides the flexibility to alternate from micro volume centrifugation to medium volume centrifugation and all at an impressive maximum speed of 14 000 RPM 20 290xg with the FA15C rotor Furthermore the V14R incorporates powerful and efficient refrigeration whilst the absence of refrigeration in the Velocity 14 further reduces its footprint by at least 50 compared to that of the Velocity 14R Smart Compact 3 in 1 Design The versatile design of the Velocity 14 14R centrifuges offers the best of both worlds from the perspective of micro volume and medium volume centrifugation The FA15A rotor is sufficiently fast and yet accommodating for up to 24 x 1 5 2 ml tubes with a terminal velocity of 14 000 RPM 18 726 x g whilst the FA15C rotor has sufficient capacity fo
61. stics gt Microtubes rotor and 8 strip rotor included gt Rotors can be easily exchanged without tools gt Compact design gt Simple amp user friendly operation gt Quiet operation noise level lt 45dB VELOCITY 6p SPECIFICATIONS Velocity 6p Maximum Speed 6 000 RPM Maximum RCF 2 910 xg Run Time Continuous Rotor Standard 8 x 1 5 2 0 ml 2 x 8 strip PCR or 16 x 0 2 ml PCR tubes Rotor Optional Dimensions 155x 175x 125 mnulwox don Weight 1 kg Power Supply AC 110 220V 50 60Hz PRODUCT CATALOG NUMBER Velocity 6u Micro Fuge with microtube rotor amp tube stripes rotor 110 220V 50 60Hz V6U The C Master Range Thermal Cyclers u B E a a U U e x i a a a a LI a P LI PC 4 i ea i E i F i m J E a j 4 TEE a i i 7 ah me 1 i f i a Mi Mj i r amp r E mm C Master GI RT Thermal Cyclers y The C Master series thermal cyclers are designed with a Other Features unique combination of features to deliver excellent and reliable gt Innovative 9677 block included 96x 0 2ml and 77x 0 5m performance with easy operation and compact footprint tubes Excellent amp Reliable Performance gt Interchangeable block design To ensure that all wells are maintained at the proper gt Heated lid with adjustable pressure temperature throughout each incubation step C Master prov
62. tion Noise abating insulation in the console including lower noise fans combine to reduce the audible operating noise to lt 62 dB quite impressive for a large capacity refrigerated centrifuge such as the Velocity 10R Liquid Seeping Prevention A single continuous rubber cap with strong gasket firmly seals the motor chamber opening and drive shaft to prevent liquid from seeping into the motor and electronic components As additional back up a highly absorbent sponge positioned beneath the rubber cap soaks up any liquid or condensation which then evaporates during operation CAT NO MAX SPEED MAX RCF TUBE VOLUME TUBE DIMENSIONS ROTOR TYPE Ke Ren NG iM TUBE DESCRIPTION NOG CAPACITY ADAPTOR FA8B 8 000 9180 50 Culture V Bottom 29x 115 10x50ml N A Aluminium 8 000 9000 15 Culture V Bottom 17 x 120 10x15ml FA8B 15C 8 000 8 900 15 Round Bottom lsr is 10 x 15ml FA8B 15P FA8C 8 000 9560 50 Round Bottom 29 x 106 12x50 ml Aluminium 8 000 S700 5 Culture V Bottom 17x 120 12x 15 m erase Se 8 000 9 350 15 Round Bottom 16 5x 113 A Omm FACIE FA TOD 10 000 12 40 80 Round Bottom 38 x 106 6 x 80 ml Aluminium 10 000 11 840 50 Culture V Bottom 29 x 115 6 x50 ml FA10D 50C 10 000 12 070 50 Round Bottom 29 x 106 6 x 50 ml FA10D 50P SW3A 3 200 2500 7 50 Bottle 97 x 157 Ax750ml N A Aluminium SW4B 4 000 3500 2504 50 Bottle Culture V 61 6 x 135 amp 2X 250 ml SW4B 250P Aluminium Bottom 30 x 116 2 x 50 ml 4 000 3 500
63. tue of the long life halogen tungsten and deuterium lamps the Halo DB 20s wavelength range is an extensive 190nm 1 100nm Furthermore the dual lamp system results in higher accuracy than corresponding xenon lamps Lamp switching is automatic and selectable from a wavelength range of 325nm to 3 0nm User Friendly Operation and Information Rich LCD Display The extra large 165mm x 122mm backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format The seamless and chemical resistant keypad is designed for easy and quick selection of navigation and function features whilst protecting against any laboratory spills Other unique features include the GO TO WL short cut key to allow direct input of a new wavelength into an existing measurement Validation Functions To ensure optimum instrument performance self diagnosis incorporating a number of parameters and wavelength calibration are automatically initiated upon start up Furthermore the Halo DB 20 is equipped with a GLP GMP feature for analyses requiring validation and auditing Parameters such as wavelength accuracy wavelength reproducibility bandpass baseline flatness baseline stability and noise level can be all validated and the audit report printed Stand Alone or PC Operation The Halo DB 20 is fully equipped and capable of executing all functions in stand alone mode Simply connect a standard laser printer for dire
64. unication port Rs 232 Power DC9V 300mA Dimensions mm 160x 190x70 Weight 880 g P16 TRIS Glass refillable pH 2 in 1 combine electrode compatible to TRIS buffer MP500 temperature Electrode probe BNC connector oHMaster LAB includes electrode holder type 201T M plastic pH ATC 3 in 1 non PHM L 220 refillable electrode calibration buffers pH4 0 7 0 10 01 dust cover oHMaster BIO includes electrode holder type P16 TRIS glass 2 in 1 refillable electrode type MP500 temperature probe calibration buffers pH4 0 7 0 10 01 dust PHM B 220 cover smart Stirrer maximum 2300 rpm SDIIR The Aero Range Aero A700 Gas Chromatograph The Aero A700 is a high performance multi channel gas chromatograph designed for a broad range of analytical applications It has the analytical capability and flexibility required for laboratories performing routine analyses as well as those Involved in research and development In combination with the GS10 Autosampler the Aero A700 offers complete automation of a sequential and unattended run of up to 110 samples Improved Performance with EasyFlow Technology With the EasyFlow Technology carrier gas flows are automatically adjusted to compensate for the vairations of ambient temperature and pressure This innovative technology enhances system stability and delivers constant retention time reproducibility Up to 18 EasyFlow channels can be installed in Aero A700 Th
65. used with FAS15C 36 place rotor 36pcs pk FAS15C 02 Velocity 13p Mini Fuge The Velocity 6u and 13u are designed to operate easily and save space They also offer a high degree of convenience and ultimate safety for your laboratory application Features amp Characteristics gt Maximum speed 13 500rpm 12 300 xg gt Choices of rotors for 12 x 1 5 2 0ml tubes and 32 PCR tubes or strips gt Compact design gt Rapid acceleration lt 12 sec and deceleration lt 16 sec gt Autoclavable rotor gt Safe operation with lid lock function gt User friendly control panel with LCD display Maximum Speed 13 500 RPM Maximum RCF 12 300 x g Run Time Up to 30 minutes or HOLD Continuous Rotor Standard 12 x 1 5 2 0 ml tubes Rotor Optional 32 x 0 2 ml PCR tubes or strips Dimensions 208 x 245 x 145 mm w x d xh Weight 4 4 kg Power Supply AC 200 240V 50 60Hz or AC 110 120V 50 60Hz Velocity 13u Mini Fuge with FA13A rotor amp FA13 02 Adapters 200 240V 50 60Hz V13U 2A Velocity 13u Mini Fuge with FA13A rotor amp FA13 02 Adapters 110 120V 50 60Hz V13U 1A 12 place rotor 1 5 2ml x 12 13 500rpm FAI3A 32 place rotor 0 2m x 32 PCR tubes or 4x 8 strip PCR tubes 6 000rpm FA6B 0 2ml PCR tube rotor adapter used with FA13A rotor 12pcs pk FA13 02 0 5ml PCR tube rotor adapter used with FA13A rotor 12pcs pk FA13 05 Velocity bu Micro Fuge Features amp Characteri
66. utosensing 24VDC 2 0A approved to EN 60601 1 2 EN 61000 6 3 EN 61000 6 1 EN 60601 1 EN 60950 Power adapter USB Cable 4 Standard Filters User manual CD Capture96 Control Software scope of Supply MikroWin2010 Connect demo version PRODUCT CATALOG NUMBER HALO LED 96 Microplate Reader WR 302 02 LED plugin xxx wavalength in nm WR 302 xxx MikroWin2010 Lite Screening amp Curve Fit basic functions WR 302 03 Mikrowin2010 Full Version 1 Screening amp Curve Fit extended functions WR 302 04 Mikrowin2010 Full Version 2 Screening amp Curve Fit amp Kinetic extended functions WR 302 05 For more information on MikroWin2010 and it s features please visit www mikrotek de Halo MPR 96 Visible Microplate Reader The MPR 96 Microplate Reader extends the Halo range to facilitate higher throughput analyses of experiments consisting of an array of micro volume reactions typically in a 96 well plate format Naturally the MPR 96 features the same ruggedness reliability precision and reproducibility synonymous with the Halo family The Halo MPR 96 also comes standard with a comprehensive selection of on board functions for versatility and suitability to many analytical and biological applications Use either in stand alone mode or connect to a PC to maximize flexibility Superior Performance The Halo MPR 96 boasts a market leading absorbance range between 0 4 OD which is further complemented
Download Pdf Manuals